Sewage. Series VG. Air Release and Vacuum Break Valves for Sewerage and Slurry Pipelines

Similar documents
Water. Series VA. Air Release and Vacuum Break Valves for Water Pipelines

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

D-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

D-26. Combination Air Valve for Wastewater. Description. Applications. Operation. Main Features

Air in your Pipes? Choosing the Correct Air Valves For Your System. Presented by John Skalla DeZURIK, Inc.

AUTOMATIC AIR VALVES For potable water

DAV - M DAV-M. Air Release and Vacuum Break Valves. Product Catalogue. (Metal Air Valves) DAV-M

CUSTOM COMBINATION AIR VALVE

485 - NC NO/DA DN

PNEUMATICALLY ACTUATED 2-WAY

Air Valves Engineering Creative Solutions for Fluid Systems Since 1901

Air Valves. Patent Pending. Engineering Creative Solutions for Fluid Systems Since 1901

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Komfot (EC) SB v5(6) INSTALLATION GUIDE HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

AIRPRO MAX AIR VALVES. Engineering Creative Solutions for Fluid Systems Since 1901

Manufactured by Upwey Valve & Engineering Pty Ltd EZI-VAC. Air Release/vacuum Break Valve (EV/EVTA)

Crispin. The UL Series Universal Air Release Valves. Compound Lever System NPT Screwed or ANSI Class Flanges Available.

M10Si ISO Ball Valve DN¼" to DN2½"

M10F Ball Valve DN¼" to DN2½"

Series 34. Specifications

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

FT47 SG Iron Ball Float Steam Traps (DN15 to DN50)

Product Specification Sheet Number: 319

Product Data Screwed Valve bodies

US SERIES. Universal Sewer Valves. Universal Sewer Valves. Valve Function. Features Include

CHARACTERISTICS ACCESSORIES. High Efficiency Pilot Operated Safety Valves

USE OF MAZZEI INJECTORS IN PRESSURIZED SPRINKLER APPLICATIONS

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

The Universal Sewer Air Release Valve is designed to permit

Product Specification Sheet Number: 305

QHD1 TABLE OF CONTENTS. Gear Pump Catalogue Table of Contents

M5200 Industrial Pressure Transducer

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

PRECISION UK Ltd DUPLEX AGSS PLANT

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 3 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 80. A JDA Global Company

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14, Rev.

PUMPS Construction Sites Mining Barges and Ships Utilities Industrial Applications Municipalities Sewage Systems

September Leopold Sludge Collection Equipment

Automatic Recirculation Valves One Step Centrifugal Pump Minimum Flow Protection

SECTION 1000 ENGINEERING SPECIFICATION: AIR STRIPPER (REMOVABLE TRAY)

APCO ASU COMBINATION AIR VALVE

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

Gauges and Thermometers

OPERATION MANUAL.25 METALLIC PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM

High Torque Low Speed Motors MR - MRE

DK/CP DN PVC-U / PVC-C / PP-H / PVDF. Pneumatically actuated 2-way diaphragm valve

AVK SERIES 854 BALL FLOAT VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR BALL FLOAT VALVES

MEDIUM VELOCITY WATER SPRAY NOZZLE

Valves For Cryogenic Applications

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

PRESSURE CONTROL VALVES SABS 198

Graphic Symbol 100 L 140 G25. R -M V 4 4 G P E. Perm.* 2 Magnet. Differential Pressure P. Connection. R: BSP.F Thd. O: Not Fitted.

Max~Flo Features and Benefits. Max~Flo Dimensions. Adaptor Dimensions. Diaphragm Valve Technical Specifications. Product Code. a mm. b mm.

Installation, Operation and Maintenance Manual. TOM WHEATLEY Piston Check Valve TOM WHEATLEY

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1

PRE-PLUMBED SEWAGE SYSTEM

Figure DC03. Double check valves for medium hazard rated applications BSP screwed connections. Features

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Symbols used: Please, pay attention to the following symbols throughout this document emphasizing particular information.

MCS TYPE B FOAM MAKER & FOAM CHAMBER NDD010. Approvals: UL, ULC

PUMP SIZE Flow rate at 1500 rpm lt/min Operating pressures bar

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Series 20 Axial Piston Pumps. Technical Information

Design Aids For Structural Welded Wire Reinforcement (Metric Units for WWR/Rebar Comparison Tables)

Series 900 Minifolds. Aluminium Air Distribution Manifolds. Manifolds & Minifolds. Technical Specifications. hnl-uk.com. Series 900 Minifolds

M Series Condensate Recovery Unit

Rotary inlets for pressurised oil, compressed air

Series 20 Axial Piston Pumps. Technical Information

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

SOA - Orifice Assembly

MrPEX 1 ½ " Brass Manifold Installation Guide

GB-35. Submittal Specifications Installation Application Specific Details. PART #: XX DWG BY: C. O'Boyle DATE: 10/08/2015 REV: 0 / /201_ ECO:

MFP14, MFP14S and MFP14SS Automatic Pumps

Penn Valley Pump Company Design Information for Double Disc Pumps

Low Speed High Torque Motors

Series 36-WW COMBINATION AIR VALVES DATA AND SIZING WASTEWATER SERVICE. (Single Body Style) Installation. Specifications. Purchase Specification

GENO -MX 1" - MX DN 100 backwash filter. Intended use. Scope of supply. Function. Structure

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

AN EXPLANATION OF CIRCUITS CARTER YH HORIZONTAL CLIMATIC CONTROL CARBURETER

Y690A Series Pressure Reducing Regulators

EPIC J3413. Uniclass L L2123. CI/SfB (52.5) In6. The most advanced drainage system of its kind. ACO Qmax. Technical Data

Wilfley. Model. Technical Handbook. Centrifugal Slurry Pump

S0300-BV-CAT-020 VACUUM PUMP/SKIMMER SYSTEM. System - P Vaccuum Pump/Skimmer System P /12/2018 9:00:21 AM

RP SERIES 200 psi Mill-type Cylinder

Installation and Operation Manual

Spiratec ST14, ST16 and ST17 Sensor Chambers and Sensors

CONTENTS. Purpose Model meaning Conditions of use Rotating direction Structures description...02

MrPEX 1 ¼ Stainless Steel Manifold. Installation Guide

R2F Compact Commissioning & 4 Port Control Valve Fan Coil Unit Valve Set Module

Spool Valve Hydraulic Motors Series J

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS .5 METALLIC PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 15

Experiment (4): Flow measurement

Kawasaki Motors Corp., U.S.A. Precision Machinery Division. Staffa Fixed Displacement Hydraulic Motor

Viking SL Industrial Lobe Pump Series

Kawasaki Motors Corp., U.S.A. Precision Machinery Division HMB 325. Staffa Fixed Displacement Hydraulic Motor

Horizontal Double Suction Volute Pump Type CN. Pipe line

Operation and Maintenance Manual

Transcription:

Sewage Air Release and Vacuum Break Valves Updated June 2015

Range explanation for VA and VAC VAS VAS VAC VA series ( water ) Vacuum break and air release Size Press Bar Valve ref number 025 25 025VA25 050 25 050VA25 080 25 080VA25 100 25 100VA25 150 25 150VA25 200 25 200VA25 Inlet Screwed Screwed General This series of valves is designed for releasing air, breaking vacuum and some syphonic applications on pipelines The VA series are for application on drinking water pipelines ( potable water ) and the series are for sewage or slurry pipelines The basic principle is to vent via an antishock orifice and break vacuum via a full valve size intake orifice. VA series ( water ) Vacuum break and air release Size Press Bar Valve ref number 025 40 025VA40 050 40 050VA40 080 40 080VA40 100 40 100VA40 150 40 150VA40 200 40 200VA40 series ( sewage ) Vacuum break and air release Size Press Bar Valve ref number 050 10 05010 080 10 08010 100 10 10010 150 10 15010 200 10 20010 series ( sewage ) Vacuum break and air release Size Press Bar Valve ref number 050 16/25 05016/25 080 16/25 08016/25 100 16/25 10016/25 150 16/25 15016/25 200 16/25 20016/25 Inlet Screwed Screwed Inlet Flg/ Scr Inlet Syphon Option The range allows for special a syphon application where only an air out function is required and the valve size can be reduced to suit the antishock size Note : By special request only Options Digit 1 ( valve material etc) 0 = Standard Valve 304 Stainless ( * see Valve Data sheet ) 1 = Standard Valve 316 Stainless 2 = Full 304 Stainless valve, inc attachment flange 3 = Full 316 Stainless valve, inc attachment flange 4 = Standard Valve 304 Stainless valve - Flange as option 5 = Standard Valve 316 Stainless valve - Flange as option Digit 2 ( porting and screen) 0 = None 1 = Pressure port 2 = Pressure port, screens 3 = Flushing port 4 = Flushing port, screens 5 = Screens Digit 3 ( Spare ) End Connection Screwed 1 inch BSPT = 1 inch BSP tapered male 2 inch BSPT = 2 inch BSP tapered male BS 4504 T10 BS 4504 T16 BS 4504 T25 BS 4504 T40 BS 10 TE BS 16 TF BS 4504 T10 BS 4504 T16 BS 4504 T25 BS 4504 T40 SABS 1123 T16 SABS 1123 T25 SABS 1123 T40 Valve Ref number example Size Pressure Options End connection 080 VA 25 320 SABS 1123 T25 Range Explanation METRIC June 2015

Software design parameters - metric VAS VAC VAS We have manufactured and designed air release valves for 30 years. The Vacuvent design allowed us to look at various factors from manufacture, service, materials to performance. The process has been driven largely by the now prevalent use of hydraulic predictive programs. The subsequent software data together with actual testing has led us to a more optimised valve. These are the parameters Through Areas ( large orifice ) A minimum 1:1 ratio of through area versus intake or riser bore, including cover plates and screens. The antishock orifices are spring loaded to the closed position but the spring force is only just enough to hold the upper float in the closed position. Effectively the spring force can be discounted ( the mass of this float acts in a downward direction and assists opening ). The valve is fully open during the vacuum cycle. Exhaust is always via the antishock orifices. Valve size ( Water ) VA 25 50 75 100 150 200 Through Area ( valve inlet ) mm2 491 1963 4418 7854 17671 31416 Dia antishock up to 25 Bar 4 6.4 8 10 12.7 16 Dia antishock up to 40 Bar 3.2 5 6.4 8 10 12.7 Dia Small Orifice 1.4 1.0 1.4 1.0 1.4 1.7 1.4 1.7 1.8 1.4 1.4 1.8 Valve size ( Sewage ) 50 75 100 150 200 Through Area ( valve inlet ) mm2 1963 4418 7854 17671 31416 Dia antishock up to 25 Bar 6.4 8 10 12.7 16 Dia Small Orifice 1.4 1.0 1.4 1.7 1.4 1.7 1.8 1.4 1.4 1.8 Intake curves Diff Press Bar Gauge 0 0 0 0 0 0 0 Water and Sewage series VA and -0.05 52.7 210.6 539.2 842.5 1895.7 3370.1 Output m3/hr -0.1 71.6 286.2 732.8 1145.0 2576.2 4579.9-0.2 104.0 415.9 1064.6 1663.4 3742.7 6653.8-0.3 124.8 499.0 1277.5 1996.1 4491.3 7984.5 Suggested Max Diff press -0.35 132.3 529.3 1354.9 2117.1 4763.5 8468.4-0.4 137.7 550.9 1410.3 2203.5 4957.9 8814.1-0.5 145.8 583.3 1493.2 2333.1 5249.6 9332.6-0.6 149.9 599.5 1534.7 2397.9 5395.4 9591.8 Exhaust Diff Press Bar Gauge 0 0 0 0 0 0 0 Water VA 25 221 566 885 1383 2231 3541 40 224 574 897 1402 2246 3558 Exhaust Diff Press Bar Gauge 0 0 0 0 0 0 0 Sewage 10 0 236 369 576 929 1475 25 0 566 885 1383 2231 3541 Coefficient of discharge CD Anti shock Exhaust CD = 0.82 For software program inputs Vacuum intake Large Orifice CD = 0.4 The data shown is at a standard atmosphere 1.01325 Bar @ 20 deg C If you require further info please contact Shaun Clegg at shaun@ivmsa.co.za or info@vacuventvalves.com Software design parameters METRIC June 2015

Water VAS VAC VAC 05010 10 Bar ( Screwed ) 50 mm / 2.0 inch 0.5 to 10 Bar 2 inch (50 mm) Screwed BSPT Anti shock orifice 6.4 mm Dia 208 mm dia x 582 mm long 17.0 kg 05010 METRIC June 2015

Water VAS VAC VAC 05010 10 Bar 50 mm / 2.0 inch 0.5 to 10 Bar 2 inch (50 mm) Anti shock orifice 6.4 mm Dia 208 mm dia x 529 mm long 18.0 kg 05010 METRIC June 2015

05025 25 Bar 50 mm / 2.0 inch 0.5 to 25 Bar 2 inch (50 mm ) Anti shock orifice 6.4 mm Dia 208 mm dia x 579 mm long 18.0 kg 05010 METRIC June 2015

08010 10 Bar 80 mm / 3.0 inch 0.5 to 10 Bar 3 inch (80 mm Dia ) Anti shock orifice 8.0 mm Dia 238 mm dia x 630 mm long 30.0 kg 05010 METRIC June 2015

08025 25 Bar 80 mm / 3.0 inch 0.5 to 25 Bar 3 inch (80 mm Dia ) Anti shock orifice 8.0 mm Dia 238 mm dia x 680 mm long 32.0 kg 05010 METRIC June 2015

10010 10 Bar 100 mm / 4.0 inch 0.5 to 10 Bar 4 inch (100 mm Dia ) Anti shock orifice 10.0 mm Dia 288 mm dia x 626 mm long 36.0 kg 05010 METRIC June 2015

10025 25 Bar 100 mm / 4.0 inch 0.5 to 25 Bar 4 inch (100 mm Dia ) Anti shock orifice 10.0 mm Dia 288 mm dia x 668 mm long 37.0 kg 05010 METRIC June 2015

15010 10 Bar 150 mm / 6.0 inch 0.5 to 10 Bar 6 inch (150 mm Dia ) Anti shock orifice 12.7 mm Dia 423 mm dia x 821 mm long 78.0 kg 05010 METRIC June 2015

15025 25 Bar 150 mm / 6.0 inch 0.5 to 25 Bar 6 inch (150 mm Dia ) Anti shock orifice 12.7 mm Dia 423 mm dia x 973 mm long 80.0 kg 05010 METRIC June 2015

20010 10 Bar 200 mm / 8.0 inch 0.5 to 10 Bar 8 inch (200 mm Dia ) Anti shock orifice 16.0 mm Dia 463 mm dia x 923 mm long 100.0 kg 05010 METRIC June 2015

20025 25 Bar 200 mm / 8.0 inch 0.5 to 25 Bar 8 inch (200 mm Dia ) Anti shock orifice 16.0 mm Dia 463 mm dia x 1073 mm long 108.0 kg 05010 METRIC June 2015

General sizing and operation notes Basic Operation Vacuvent have full valve size intakes ( large orifices ) but control the exhaust exclusively via the Anti-Shock orifices No exhaust is vented via the large orifice and this function is specifically designed for ( further reading see technical information ).The valve range covers most applications as standard but still allows the designer some scope to specify more accurately. Basic Principles When a section drains down the AV at the apex must be sized to protect the pipe and seals until next valve lower down opens. So intake can not be calculated by adding all the valves on that section. Exhaust however is another matter and its feasible in some instances to add all the anti shock capabilities for one section. Its also important to ensure that enough head ( including dynamic) is available to seal the valve off otherwise a syphon valve may be required.this is a consideration on pumping systems where the final section after the apex has the possibility of draining down faster than the pumping rate. Another factor is the differentiation between designed flow rates and possible drainage rates. Drainage rates are generally estimated 2 times the designed flow rates ie 1-2 m/sec flow rate and say 2-4 m/sec drainage. If the pipe is protected for vacuum, generally the exhaust capability is more than adequate Sizing Most sizing is based on the need to protect the pipeline from a negative pressure, vent the initial air, and to vent the pressurised air with the importance generally in that order. A good start is to select a scouring or drainage rate based on rupture or draining of 2-3 times the designed flow rate of that particular section. Size the AV to protect the pipeline and seals from low pressure within the pipeline during draining or other pipeline disturbances (eg pump trip). One accepted method is to limit the internal pressure to 3.5 m P ( 0.35 Bar) below atmospheric @ sea level. The AV intake data in each individual valve catalogue indicates that point and the resultant inflow of air. Placement The graphic shows most of the common places where AV ( air release valves ) are fitted.high points are a natural start, also where the pipeline crosses obstacles like rivers and roads. Check for syphon application above the hydraulic grade line.to control pump start and pump trip, AV should be placed before and after the check valve. Hydraulic Grade line Pumped example For Syphon application On long sections not more than 600 meters apart Non return Pump Under river or services crossing Over roadways or services crossings Disclaimer : Sizing, placement and application of Air Release Valves is beyond the scope of this single page and the above is only a basic outline of the methods. For more technical information consult the " Technical section" and " Links " section of the Vacuvent website. METRIC May 2014