IDMHDV-120. Lever Operated Diaphragm Valve. User Manual

Similar documents
Micron-S Precision Dispensing Tips

TS1251 PRESSURE DISPENSER USER'S MANUAL

Techcon Systems TS5620 Series Diaphragm Valve. User Guide

2 Model 485 Dispensing Valve User Guide

Techcon Systems TS5322 TS5322D Adjustable Mini Spool Valve. User Guide

2 Model 826 Dispensing Valve User Guide

User Manual for the ProFlow 1K Release: User Manual for the ProFlow 1K_Rev_A PVA Support Hub. User Manual for the ProFlow 1K

If you frequently need to repair damaged circuit boards, the all-in-one Professional PCB Repair Kit is what you need.

Techcon Systems TS5540-MS Micro Spray Valves

Loctite Micro Needle Valve Part Number EQUIPMENT Operation Manual

WORLDWIDE EQUIPMENT. Hand-held Applicator OPERATION MANUAL GLOBAL AVAILABILITY GLOBAL SERVICE

AirPulse TM Ultra Small Dot Positive Displacement Valve

Paint/Solvent/Dump Valve and Flow-Through Valve

Techcon Systems TS7000 Series Interchangeable Material Path Rotary Valve

xqr41v Series Needle Valve

Hard Seat Fluid Pressure Regulator

SD Bendix E-10PR Retarder Control Brake Valve DESCRIPTION. OPERATION - Refer to Figure 2

EQUIPMENT Operation Manual

2 Model 455 Dispensing Valve User Guide

Identify and Assemble the Pneumatic Components

EP-2 Si Three-Piston Pump

2 Micro-Dot Manual Syringe Dispenser User Guide

Operation, Installation, Maintenance and Repair Guide. HighFlo (HF) Control Handle. SERVICE BULLETIN SB 3097 Rev. A 6/14

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V 3800V 3900V

Techcon Systems TS5000 Series Rotary Valve

781Mini Series Spray Valve

Paint Pumps INST Manual

Operating Manual High Viscosity Dispense Valve Item #

EP-2 Three-Piston Pump

EQUIPMENT Operation Manual

Cyclone II. Cyclone. and OPERATOR S MANUAL IMPORTANT- READ OPERATOR S MANUAL BEFORE USE.

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

SD Bendix Manual Slack Adjusters DESCRIPTION ADJUSTING MECHANISM OPERATION

Tooling Assistance Center

SERVICE INSTRUCTIONS Air Motor

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3400V 3500V 3700V

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15

INSTALLATION GUIDE. RMS500, RMS501, RMS502, RMS503, RMS506, RMS507, RMS508, RMS509, -OR Manual Revision:

EQUIPMENT Operation Manual

Inverted High Pressure Fluid Filters

DO NOT INSTALL, OPERATE, OR MAINTAIN AN ATI PRODUCT UNLESS TRAINED AND QUALIFIED IN PRODUCT AND ACCESSORY INSTALLATION, OPERATION AND MAINTENANCE.

SD Bendix DD-3 & SD-3 Safety Actuators PUSH PLATE & SHAFT ASSY. LOCKPORT SERVICE DIAPHRAGM SEPARATOR LOCKING PISTON O-RING LOCKING PISTON

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM

OpTK. Product Instruction Manual. Spring Cylinder Rotary Actuators INTRODUCTION SAFETY INFORMATION INSTALLATION. Leading Technologies For Control

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

Relius UV-Cure Adhesive Coating Dispenser Manual

Sachs shock manual. ( ) 2 & 4 Stroke RR Enduro. ( ) RS Dual Sport

Valtek Flow Boosters

Operating Manual. VoluDrop Dispenser UV

NOZZLETECH INC. INSTRUCTION MANUAL CEV00 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA

INSTALLATION GUIDE. RMS510, 511, 512, 513, 511MC 510-OR, 512-OR Manual Revision:

Instruction Manual. Maximum Operating Pressure 700 bar

Anderson Greenwood Series 400 Piston Pilot POPRV Installation and Maintenance Instructions

POWER STEERING PUMP REBUILDING SPK101 Read instructions completely before removal & disassembly

Rev. E Sept 06. VP300 INSTRUCTION MANUAL Part # DISPENSING VALVE MODEL VP300 INSTRUCTION MANUAL

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.

Operation Manual Advanced - Conventional Gravity Feed Spraygun

I N S T R U C T I O N M A N U A L

STAINLESS STEEL DETERGENT INJECTOR AW

3-TONNE GARAGE JACK OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: CTJ3000GB PART NO: ORIGINAL INSTRUCTIONS

Air Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

TK08 TUNING KIT TECHNICAL MANUAL FOR 16/26/27/28 SERIES SHOCKS Revised 6/17/14

Dispensing. Monitoring Systems. Loctite Fluorescence Detector, Item 98083

SERVICE INSTRUCTIONS. Material Pump

TK08 TUNING KIT TECHNICAL MANUAL FOR 16/26/27/28 SERIES SHOCKS Revised 6/25/14 Tech Line: (952) Fax (952)

Operating Guide Model 800 Dispenser

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

Tissue Master. User Manual

SERVICE KITS REBUILD KIT DESCRIPTION CHART MODEL DESCRIPTION CHART SPECIFICATIONS X X 1 - B X - X X X - B

Installation Manual For ISL98, ISL03, ISL07, ISC07

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

SD Bendix E-7 Dual Brake Valve DESCRIPTION OPERATION APPLYING: NORMAL OPERATION - PRIMARY CIRCUIT PORTION

20 TONNE HYDRAULIC PRESS MODEL NO: CSA20FBT

ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance

GARAGE JACK MODEL NO: CTJ3000QLB PART NO: OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS

Auto-Flo Panel Reinforcement Automatic Dispensing Valve

TLD 2500 Tube Testing Guns

NOZZLETECH INC. INSTRUCTION MANUAL CEV10 01/31/ C EAST COLONIAL DRIVE ORLANDO, FL USA

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with bead or slot modules.

Fisher 2052 Diaphragm Rotary Actuator

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with CF200PAD right-angle modules.

Binks FRX20 FLUID SECTION

The DispensGun and components are manufactured by Nordson EFD in the U.S.A.

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

UV PROCESS SUPPLY, INC.

SD Bendix PP-7 Trailer Supply Valve FUNCTION AND DESCRIPTION

Hydraulics. Part B, Section 1. This section covers the following unit configurations. 3700V

Swing-Flex Check Valve

TOPAZ Service Guide. Full Service

EQUIPMENT # OPERATION MANUAL DISPENSING SYSTEM

3 Scotch-Weld. User s Manual. Polyurethane Reactive (PUR) Easy Adhesive Applicator

Back Pressure Regulator

Anderson Greenwood Series 800 POSRV Installation and Maintenance Instructions

Double Diaphragm with Pressure-Type Leak Detector. For MILROYAL, CENTRAC B And MAXROY

Auto-Flo Air-Assist Automatic Dispensing Valve

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

D-04/G-04 Maintenance

SERVICE INSTRUCTIONS. Transfer Pump

EP1306N 5 Gallon Can Extruder System Rev. A June EP1306N Operation Manual

Transcription:

IDMHDV-120 Lever Operated Diaphragm Valve User Manual www.intertronics.co.uk/idmhdv-120 17 Station Field Industrial Estate Banbury Road, Kidlington Oxfordshire, England OX5 1JD t 01865 842842 e sales@intertronics.co.uk www.intertronics.co.uk

Thank you for purchasing the IDMHDV-120 Lever Operated Diaphragm Valve. For optimum performance and results, please read this manual carefully. Ensure that all operators and personnel are adequately trained for use with this product. This document is based on information available and correct at the time of publication. The statements, technical information and recommendations contained herein are based on knowledge we believe to be reliable but they are not to be construed in any manner as warrantees expressed or implied. The user shall determine the suitability of the product for his intended use and the user assumes all risk and liability whatsoever in connection therewith. Allen is a registered trademark of the Apex Tool Group, LLC. For any queries regarding this product, please contact Intertronics directly.

Table of Contents Theory of Operation... 2 Safety... 2 Set Up... 2 Diaphragm Actuation... 3 Starting Up the Valve... 3 Shutting Down the Valve... 3 Diagram #IDMHDV-120... 4-5 Operation... 6 Routine Cleaning: Disassembly... 6 Reassembling the Valve... 7 Troubleshooting... 8 Note: Throughout this manual, numbers denoted in brackets refer to the corresponding parts labelled in Diagram #IDMHDV-120 1

Theory of Operation The IDMHDV-120 is an all-plastic handheld dispense valve that uses a unique floating diaphragm design. This valve is designed with a wand-style body to make it ergonomic for a variety of handheld applications. The all-plastic construction allows adhesives such as cyanoacrylates and anaerobic materials to be dispensed through the valve along with a variety of other low to medium viscosity fluids. Applications can include potting and the dispensing of dots and beads. The IDMHDV-120 body comprises: 1) Piston and lever section (aluminium top cap with spring loaded lever) 2) Fluid section (acetal body with PTFE diaphragm and polyethylene luer adapter) The diaphragm is clamped in between the piston and lever section and fluid section, separating the two sections. The piston and lever section is an aluminium top cap that houses a spring-loaded piston, which presses against the diaphragm to keep the valve in the closed position. When the lever is depressed, it will raise the piston off the diaphragm allowing it to float upward to dispense fluid through the wand-style body to the dispense tip. Wetted parts on the IDMHDV-120 include: Acetal PTFE Polyethylene Safety Due to material contents being under pressure, eye protection is recommended for operators. Refer to the SDS for the material being dispensed for other precautions. Set Up The IDMHDV-120 does not require an air source for actuation, but relies only on the operator to depress a lever to actuate the valve. Constant material pressure is applied to the diaphragm of the valve, which is held in place with the spring-loaded piston. When the lever of the valve is depressed, the plunger lifts off the diaphragm and fluid is allowed to dispense. When the lever is released, the spring will again force the plunger into the diaphragm to return the valve to the closed position. Note that the valve is normally in the closed position. Fluid is supplied to the IDMHDV-120 through the 1/8 NPT port located on the acetal fluid section of the valve. 2

Diaphragm Actuation When the lever is depressed to lift the plunger, the diaphragm will flex under fluid pressure to allow the valve to open and dispense. Starting Up the Valve At the beginning of the day or a shift, set up the IDMHDV-120 to resume normal operation. 1) Remove the luer lock tip cap from the luer lock adapter (9) and discard. 2) Place a new dispense tip onto the luer lock adapter (9). 3) Apply fluid pressure to the valve by turning on the pressure to the fluid reservoir. 4) Cycle the valve to the open position to bleed air that may have become trapped. 3

Diagram #IDMHDV-120 Note: Throughout this manual, numbers denoted in brackets refer to the corresponding parts labelled in Diagram IDMHDV- 120 Item Description Part Number Qty 1 Valve Top Cap IDMHDV-120-V351 1 2 Diaphragm* IDMHDV-120-V323 1 3 Fluid Section IDMHDV-120-V333-NPT 1 4 5 Plunger, stainless steel Stroke Adjust Nut IDMHDV-120-214-14855 IDMHDV-120-V348 6 Standoff IDMHDV-120-V352 2 7 Handle IDMHDV-120-614-5898-1 1 8 Spring IDMHDV-120-V059 1 9 Plastic Luer Adapter* IDMHDV-120-V300-UV 10 Dowel Pin IDMHDV-120-V061 1 11 Set Screw IDMHDV-120-V060 3 12 Socket Head Cap Screw IDMHDV-120-SH8-32X0.5 4 * These parts are included in the IDMHDV-120-SP Spare Parts Kit (10 x Diaphragm (IDMHDV-120-V323), 1 x Plastic Luer adapter (IDMHDV-120-V300-UV)). Contact Intertronics to order. 1 1 1 4

56mm 164mm 5

Shutting Down the Valve At the end of the day or shift, shut down the IDMHDV-120 dispense system in order to keep material from curing inside the valve. 1) Remove the disposable dispense tip from the luer adapter (9) and discard. 2) Thread a luer lock tip cap onto the luer adapter (9) 3) Relieve fluid pressure on the valve by turning off air pressure from the fluid reservoir. Operation 1) Set up the valve as outlined in Starting up the Valve (page 3). 2) Be sure the valve is not aimed toward anyone. Pressurise the fluid delivery system. Note: The fluid pressure must be set to a minimum of 15psi to flex the diaphragm to the open position. 3) Cycle the valve to the open position by depressing the lever (7) to purge. Fluid should begin to dispense from the tip of the valve. Continue dispensing until all air is removed. 4) Check fluid connection for leaks. If the valve is leaking or dripping, refer to the Troubleshooting section (page 9). 5) Fine-tune the flow rate with the stroke adjustment nut (5). First loosen the set screw (11) with a.050 Allen key then turn the stroke adjustment clockwise to increase flow and counter-clockwise to decrease the flow rate. If the stroke is loosened too far out, the valve will not open. 6) Once the stroke adjustment setting is determined, retighten the set screw (11) using a.050 Allen key. Note: Refer to Troubleshooting section (page 9) for any problems. Routine Cleaning: Disassembly Cleaning and rebuilding the valve will be required from time to time. A spare parts kit (IDMHDV-120-SP) is available with all the normal wear parts included (10 x Diaphragm, 1 x Luer adapter). Contact Intertronics to order. 6 1) Flush the valve thoroughly with an appropriate solvent before disassembly. (Refer to SDS of fluid for suggested solvent). 2) Remove fluid pressure from the system, and then remove all fluid delivery fittings, hoses, etc. from the valve. 3) Using the tip of a 9/64 Allen key, remove the four machine screws (12) that hold the top cap (1) to the fluid section (3). 4) Lift off the top cap assembly and remove diaphragm (2). 5) Using a spanner, unthread and remove the plastic luer adapter (9) from the fluid section (3). 6) Clean all of the wetted parts thoroughly with an appropriate solvent. 7) Using a.050 Allen key, unthread and remove the set screw (11) that threads into the stroke adjustment nut (3).

8) Unthread and remove the stroke adjustment nut (3) from the piston (4) which will allow the piston and spring (8) to slide out through the bottom of the top cap (1). 9) Using a.050 Allen key, unthread and remove the two set screws (11) that thread into the standoffs (6). 10) Slide the dowel pin (10) out of the standoffs (6) and lever (7) to separate them from the top cap (1). Replace components with spares provided in the spare parts kit, if necessary. Reassembling the Valve The diaphragm must be assembled into the valve with the PTFE side facing the fluid. Note: The PTFE side is the thinner, smooth side. Thick silicone backing Thin PTFE Side 1) Slide the standoffs (6) through the bottom of the top cap (1) and rotate the threaded sides outward. 2) Place the lever (7) in between the standoffs (6) and insert the dowel pin (10) to hold in place. 3) Using a.050 Allen key, thread the two set screws (11) into the standoffs (6) to hold the dowel pin (10) in place but leave loose until the valve is assembled. 4) Place the spring (8) over the plunger (4) and insert the assembly through the bottom of the top cap (1) and through the cut-out in the lever (7). 5) Thread the stroke adjustment nut (5) onto the plunger (4) to hold the piston and lever assembly together. 6) Using a.050 Allen key thread the set screw (11) into the stroke adjustment (11). 7) Place the diaphragm (2) onto the groove of the fluid section (3) with the thin PTFE side down, against the fluid. 8) Mount the top cap (1) over the diaphragm (2) and assemble to the fluid section (3) using the four socket head cap screws (12), tightening them down evenly with a 9/64 Allen key. 9) Tighten the two set screws (11) that thread into the standoffs (6) using a.050 Allen key. 10) Thread the plastic luer adapter (9) into the bottom of the fluid section (3) and tighten using a spanner. Note: Be sure not to over-tighten the luer adapter (4). 7

Troubleshooting Problem Possible Cause Corrective Action Valve does not cycle Fluid pressure too low Worn diaphragm Increase fluid pressure above 15psi Replace diaphragm Material leaks from valve tip Worn diaphragm Air bubble trapped in fluid body or in dispense needle Replace diaphragm Flip valve upside down and cycle until air bubbles are removed Valve does not dispense anything Fluid pressure is too low Material cured in fluid section Worn diaphragm Increase fluid pressure above 15psi Disassemble and clean valve Replace diaphragm Air bubbles in fluid Valve not properly purged Problem with fluid delivery system Flip valve upside down and cycle until air bubbles are removed Diagnose and repair Dispense rate too fast Fluid pressure set too high Stroke adjustment set too high Dispense tip gauge too large Decrease fluid pressure Turn stroke adjust counterclockwise Replace dispense tip with smaller size Dispense rate too slow Fluid pressure set too low Stroke adjustment set too low Dispense tip gauge too small Increase fluid pressure Turn stroke adjust clockwise Replace dispense tip with larger size 8

[blank page] 9

For assistance and enquiries, please contact one of our technical specialists: 01865 842842 sales@intertronics.co.uk INTERTRONICS 17 Station Field Industrial Estate Banbury Road Kidlington Oxfordshire England OX5 1JD www.intertronics.co.uk Version 1.0 May 2017