Annex_Tumkur In-principle(Phase-I) 1)Minutes of the meeting held on )In-principle Approval_Tumkur Phase-I

Similar documents
Central Electricity Authority System Planning & Project Appraisal Division Sewa Bhawan, R.K. Puram, New Delhi

Central Electricity Authority System Planning & Project Appraisal Division Sewa Bhawan, R.K. Puram, New Delhi

Central Electricity Authority System Planning & Project Appraisal Division Sewa Bhawan, R.K. Puram, New Delhi

(i) Establishment of 400kV Pooling Station at Fatehgarh (with a provision to upgrade at 765kV level)

Central Electricity Authority System Planning & Project Appraisal Division Sewa Bhawan, R.K. Puram, New Delhi

Central Electricity Authority System Planning & Project Appraisal Division Sewa Bhawan, R.K. Puram, New Delhi

Agenda for Connectivity and Long Term (Open) Access of IPP Generation Projects in Odisha of Eastern Region

Central Electricity Authority System Planning & Project Appraisal Division Sewa Bhawan, R.K. Puram, New Delhi

4,1 '~ ~ ~ 1I1f lc/)~ul I Central Electricity Authority

FAX : Member Secretary Southern Regional Power Committee 29, Race Course Cross Road Bangalore FAX :

UP Electricity Regulatory Commission Vidyut Niyamak Bhawan, Vibhuti Khand, Gomti Nagar, Lucknow. Public Notice

Central Electricity Authority System Planning & Project Appraisal Division Sewa Bhawan: R.K.Puram New Delhi

Minutes of the 19 th meeting of the Standing committee on transmission system of Northern Region held at Amritsar on 01/10/05.

TRANSMISSION CAPACITY ADDITION PROGRAMME DURING No. 1 Introduction 1

Report. the feasibility of

KERALA STATE ELECTRICITY REGULATORY COMMISSION. NOTIFICATION Dated, Thiruvananthapuram 6 th August,2007

Central Electricity Authority System Planning & Project Appraisal Division Sewa Bhawan, R.K. Puram, New Delhi

Renewable Regulatory Fund (RRF) Mechanism : -

Central Electricity Authority System Planning & Project Appraisal Division Sewa Bhawan, R.K. Puram, New Delhi

Additional Agenda for 31 st Standing Committee Meeting of Power System Planning for Northern Region

Case No. 109 of Coram. Shri Azeez M. Khan, Member Shri Deepak Lad, Member. Maharashtra State Electricity Distribution Co. Ltd.

SAUDAMINI, Plot No.2, Sector-29, Gurgaon, Haryana Powergrid Corporation of India Ltd., SAUDAMINI, Plot No.2, Sector-29, Gurgaon

Wheeling charges, Banking charges & Cross Subsidy Surcharge for Solar Power Generators

Case No. 163 of In the matter of

No. 15/3/2018-Trans-Pt(1) Government of India Ministry of Power Shram Shakti Bhawan, Rafi Marg, New Delhi **** OFFICE MEMORANDUM

Central Electricity Authority System Planning & Project Appraisal Division Sewa Bhawan, R K Puram, New Delhi

Central Electricity Authority System Planning & Project Appraisal Division Sewa Bhawan, R.K. Puram, New Delhi

Before the. Case No. 106 of 2009

Distribution List Chief Engineer (SP & PA) Central Electricity Authority Sewa Bhawan, R.K.Puram, New Delhi FAX :

Policy for Net-Metering based Renewable Energy Applications, Madhya Pradesh, DRAFT

Guidelines for Solar Grid Power Projects

Infrastructure Revitalization in India Power System Operation Corporation (POSOCO) New Delhi, India

Thereafter, the agenda items were taken up.

Case Nos. 12 & 48 of 2009

य प र षण ल ख REGIONAL TRANSMISSION ACCOUNT. April 2018

February 13, Docket No. ER ; ER Response to Request for Additional Information

Bihar Electricity Regulatory Commission Vidyut Bhawan, J.L.Nehru Marg, Patna

Enhancing Grid Stability in India

Uttar Pradesh Electricity Regulatory Commission, Lucknow

EXTRA ORDINARY 16 AASHAADHA, 1937(S) BIHAR ELECTRICITY REGULATORY COMMISSION

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS.

100 MW Wind Generation Project

Agenda of 11 th System Studies Meeting in NER

Maharashtra Electricity Regulatory Commission (Renewable Purchase Obligation, Its. Regulations, 2016 STATEMENT OF REASONS

2. Director (W &P) UPPTCL, Shakti Bhawan Extn,3rd floor, 14, Ashok Marg, Lucknow (Fax: )

RATE ORDER 2015 UNIFORM ELECTRICITY TRANSMISSION RATES January 08, 2015

STATE LOAD DISPATCH CENTRES (SLDC)

ROLE OF HAREDA IN NET METERING. By : P.C. Sharma Project Officer

GOVERNMENT OF NCT OF DELHI

PUBLIC NOTICE. 1. Central Electricity Authority (Technical Standards for Connectivity of Distributed Generation Resources) Regulations, 2013.

System Status Briefing

JAMMU AND KASHMIR STATE POWER DEVELOPMENT CORPORATION LIMITED PUBLIC NOTICE

CONFERENCE ON TRANSMISSION & DISTRIBUTON MR N C VENUGOPAL TRANSMISSION SECTOR GROWTH & CHALLENGES. DATE 2 ND NOVEMBER 2012

STATUS OF CROSS BORDER TRADE AND ENERGY MARKET NEPAL-INDIA EXCHANGE

1. Confirmation of the minutes of 19th meeting of the Standing Committee on Transmission system Planning held on at Amritsar, Punjab.

Agenda Note for Standing Committee Meeting of Power System Planning in ER

Ministry of New and Renewable Energy (Jawaharlal Nehru National Solar Mission) Form B for Project Proposals for

Case No. 77 of In the matter of

Policy for Net-Metering based Renewable Energy Applications, Madhya Pradesh, DRAFT

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

PLANNING, ELIGIBILITY FOR CONNECTION AND CONNECTION PROCEDURE IN EMBEDDED GENERATION

The Electric Power System

Minutes of the 4 th Meeting of Standing Committee on Power System Planning of North Eastern Region held on 13 th Dec., 2014

Central Electricity Authority ftf~o "5TUTTID m~';jt ~ct l:f~en';f '5f<qTlf-I I -..:;.. "" Power System Planning & Appraisal Division=II

BANGALORE ELECTRICITY SUPPLY COMPANY LIMITED

Transmission Competitive Solicitation Questions Log Question / Answer Matrix Harry Allen to Eldorado 2015

Policy & Regulatory Issues : Solar & Wind. Shri Rajinder Kumar Kaura CMD, Bergen Group India 21 st August 2014

Power Sector Trends: Focus on States

Application for Commission Approval to Construct a Generating Station Pursuant to Public Utilities Article Section and

Wind Turbine. Commissioning Utilizing Mini-Grid Power. Scottish Renewables Onshore Wind Conference & Exhibition Aggreko

MINUTES OF THE 47 th SLCF MEETING HELD ON

Annex to technical regulation for thermal plants above 11 kw

ROLLOVER RIGHTS OF LONG TERM FIRM TRANSMISSION SERVICE

RENEWABLE ENERGY IN JORDAN What had to be done 8 Oct 2017

ESIA Study for 1,050MW Coal Fired Power Plant, Lamu County, Kenya Need for the Project. 3 Need for the project... 2

NEWFOUNDLAND AND LABRADOR BOARD OF COMMISSIONERS OF PUBLIC UTILITIES AN ORDER OF THE BOARD NO. P.U. 17(2017)

Petition No. 1051, 1054 & 1055 of 2015 BEFORE THE UTTAR PRADESH ELECTRICITY REGULATORY COMMISSION LUCKNOW Date of Order :

Intra-State Availability Based Tariff (ABT)

Merger of the generator interconnection processes of Valley Electric and the ISO;

1. CONFIRMATION OF THE MINUTES OF THE 14 th PROTECTION SUB- COMMITTEE MEETING HELD ON 21 st March Grid Disturbances in the Southern Region

R.S.USHA CHIEF ENGINEER/ PLANNING & RC. Encl: Report and detailed estimate. To The Chief Engineer/D/Madurai Region

TRANSMISSION LICENCE NO. 1 OF 2011 LICENCE FOR TRANSMISSION OF ELECTRICITY IN THE STATE OF MAHARASHTRA

Evacuation of Wind Power in Kadapa, Anantapur and Kurnool districts of Andhra Pradesh. Revised Administrative Approval - Accorded

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation

(i) COO (CTU), POWERGRID, Saudamini, Plot No.2, Sector 29, Gurgaon (Haryana)

Training Course on Design, Installation of MW Scale Solar PV Systems & Commissioning concepts

PRAGATI ENGINEERING COLLEGE

Decision Blaze Energy Ltd. Application for an Exemption under Section 24 of the Hydro and Electric Energy Act.

SOLAR PV INTEGRATION: ISSUES & CHALLENGES with NET METERING

THE UNITED KINGDOM TYPE APPROVAL AUTHORITY

New EU Regulation on General Safety. Implementation of Tyre Aspects

QUESTION / CLARIFICATION QC-ENE-001

3mO :th c:tll '{ Government of India. Ministry of Power. Northern Regional Power Committee

/ I S S : / S T S I

APPLICATION FOR INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION

The Rollover Request customer accepts a reservation term for the rollover at least as long as that offered by any competing customer.

दव ण त र य व द य त सवमवत

:Tamil Nadu Generation and Distribution Corporation Limited: Delegation of powers of sanction to officers (TNEB Volume-II) - revised Communicated Reg

HVDC Systems in India

P. SUMMARY: The Southeastern Power Administration (SEPA) establishes Rate Schedules JW-

Transcription:

Annex_Tumkur In-principle(Phase-I) 1)Minutes of the meeting held on 16-12-2015 2)In-principle Approval_Tumkur Phase-I

Government of India Ministry of Power Central Electricity Authority PSP & PA- I Division Sewa Bhawan, R.K. Puram, New Delhi 110066 Website: www.cea.nic.in No: 51/4/PSPA-II-2015/546-50 Date: 22-Dec -2015 To 1. The Member Secretary, Southern Regional Power Committee, 29, Race Course Cross Road, Bangalore 560 009. FAX : 080-22259343 3 ED, SRLDC, 29, Race Course Cross Road, Bangalore 560 009 FAX 080-22268725 2. COO(CTU-Planning) Power Grid Corp. of India Ltd. Saudamini, Plot No.2, Sector-29, Gurgaon 122 001, Haryana. FAX : 95124-2571932 4. The Director (Transmission), Karnataka State Power Trans. Corp.Ltd., Cauvery Bhawan, Bangalore - 560 009. FAX : 080-22228367 Subject: Minutes of meeting held in CEA on 16.12.2015 to discuss the transmission system for evacuation of power from Tumkur Ultra Mega Solar Park (2000 MW). Sir/ Madam, The meeting on the transmission system for evacuation of power from Tumkur Ultra Mega Solar Park (2000 MW) was held under the chairmanship of Member (PS), CEA, on 16 th December, 2015, in CEA. The minutes of the meeting is enclosed herewith. This issue with the approval of Member (PS), CEA. Yours faithfully, -sd/- (Pardeep Jindal) Director (PSPA-II) Copy to: CEO( POSOCO),B-9, Qutub Institutional Area, Katwaria Sarai, N Delhi

Minutes of the meeting held in CEA on 16.12.2015 to discuss the transmission system for evacuation of power from Tumkur Ultra Mega Solar Park (2000 MW) 1. Member (Power System), CEA welcomed the participants and asked Director (PSPA-II) to appraise the issue and initiate the discussion. List of participants is given at Annex-I. 2. Director (PSPA-II) informed that the transmission scheme for evacuation of power from Tumkur Ultra Mega Solar Park of 2000 MW capacity at Pawagada in Karnataka, was evolved through joint studies by CEA, CTU and KPTCL. This scheme is also included in the agenda for discussion of the 39 th meeting of the Standing Committee of Power System Planning of Southern Region to be held on 28-29 December, 2015. Earlier this meeting was scheduled to be held on 7-8 December, 2014 but due to flood situation in Chennai, the meeting has been postponed to 28-29 December, 2015. PGCIL vide their letter C/SG/06/TUMKUR dated 7 th December, 2015 has requested CEA to give in-principle approval for Transmission system of Tumkur Ultra Mega Solar Power Park in Karnataka so that various implementation activities can be taken up, keeping in view the short gestation period of solar generation. He further said that this meeting has been called up so that we can take a view regarding in-principle approval for the transmission scheme after discussing various issues involved in this scheme. 3. Director (Trans.) KPTCL, said that there are Right of Way issue around Tumkur, Hiriyur and Mysore and therefore, the phasing of transmission system should be carried out very carefully. He said that the Davengiri Hiriyur -Nilamangla 400 kv transmission line is an important line for feeding power to Bangalore. He said that Tumkur Hiriyur transmission link should be reconsidered because this line would cause overloading on the Hiriyur Neelamangala 400 kv D/c line. 4. DGM(SRLDC/POSOCO), also supported that any injection into Hiriyur would cause overloading on Hiriyur Neelamangla section. 5. Director (PSPA-II), CEA informed that in the ultimate configuration, the Tumkur Hiriyur link may be opened and connected with the Hiriyur Mysore line forming a direct connection between Tumkur and Mysore. He reiterated that the Tumkur Hiriyur line is being considered only as an interim arrangement because of paucity of time as the solar generation project is coming very fast. 6. Chief Manager, PGCIL informed that Tumkur Phase-I (1000 MW) generation is scheduled to be commissioned by Sep 17 and the Phase-II by September 2018. He also informed that the solar power developer has now informed that out of 2000 MW, 1600 MW shall be consumed by Karnataka DISCOMS against earlier 1100 MW. He, however, confirmed that, at present there is no PPA with KPTCL and, therefore, this is only a target region. 7. Director KPTCL confirmed that they will be buying 1600 MW from the solar park. He said that the load at Madhugiri (new) ( Vasantanarasapura) may increase to about 600-700 MW

and, therefore, transformation capacity on Madhugiri (new) may be augmented. He also informed that the Bellary pooling station Madhugiri (Vasantanarasapura) 400 kv D/c Quad line is under construction and would definitely be completed by December, 2016. 8. PGCIL said that as per the joint studies carried out earlier with KPTCL and CEA, the Tumkur Hiriyur 400 kv line was not causing any adverse impact on the Hiriyur Neelamangla section. Director, KPTCL replied that if Tumkur Hiriyur is constructed then this should be linked with the UPCL Kannur (Kerala) 400 kv D/c line otherwise it will cause the overloading in the system. 9. Based on above discussion, system studies were carried out and following emerged ( the load flow results are given at Annex-2): (i) If LILO of both the Gooty Madhugiri 400 kv D/C and the Bellary pooling station Madhugiri D/C(Quad) are carried out at Tumkur, there may not be a need for Tumkur Hiriyur transmission link. (ii) However, if Tumkur Hiriyur transmission link is also implemented in first phase, it would not give any adverse impact on the Hiriyur Neelamangala 400 kv section and on the contrary provides some relief to this section. 10. (i) Regarding provision of 220kV bays for terminating 8 Nos of 220kV D/C dedicated transmission lines i.e: total 16 bays ( 8 in Phase-I and 8 in Phase-II) at Tumkur Pooling Station, the matter was discussed in detail. The issue here is whether the bay should be owned by the generator/ Solar Park Developer or whether they should be part of ISTS. It was observed that when an IPP builds (and owns) its DTL, the bays at ISTS terminating station are also owned by the IPP. (ii) It was brought out during discussion that, as the matter is still pending with CERC(as described below), we may agree to have the bays as ISTS subject to clarification /action by CERC. PGCIL quoted following from the SOR of the Fifth Amendment to Grant of Connectivity, Long-term Access and Medium-term Open Access in inter-state Transmission and related matters Regulations, 2009 and Central Electricity Regulatory Commission Grant of Regulatory Approval for execution of InterState Transmission Scheme to Central Transmission Utility Regulations, 2010 With regard to PGCIL suggestion to allow multiple injections with multiple drawals, it is clarified that the scheme for development of solar power park is such that there may be multiple generation developers within the park who shall be injecting at various points within the park and shall ultimately inject at interface with ISTS. Hence primafacie it will be treated as single injection at the

interface point with ISTS. The issues related to scheduling in this regard shall be dealt with by making necessary provisions in the IEGC through amendment. (iii) Further as per Second Amendment to IEGC (dated 6 th January, 2014) following is submitted regarding Connection Point and Pooling Station: Regulation 6.5.23 of the Principal Regulations shall be substituted as under: Page 6 of 7 23.With effect from 15.7.2013, Scheduling of wind power generation plants would have to be done where the sum of generation capacity of such plants connected at the connection points (called Pooling stations) to the transmission or distribution system is 10 MW and above and connection point is 33 kv and above, for pooling stations commissioned after 3.05.2010. For capacity and voltage level below this, as well as for old wind farms (A wind farm is collection of wind turbine generators that are connected to a common connection point), it could be mutually decided between the Wind Generator and the transmission or distribution utility, as the case may be, if there is no existing contractual agreement to the contrary. The schedule by wind power generating stations (excluding collective transactions) may be revised by giving advance notice to SLDC/RLDC, as the case may be. Such revisions by wind power generating stations shall be effective from 6th time block, the first being the time-block in which notice was given. There may be one revision for each time slot of 3 hours starting from 00:00 hours of a particular day subject to maximum of 8 revisions during the day 2(iiii) Pooling Station means the sub-station where pooling of generation of individual wind generators or solar generators is done for interfacing with the next higher voltage level. 11. After further discussion, following was decided in the meeting: (i) As the matter is slated to be discussed on 28-29 December, 2015, in-principle approval only for phase-i may be considered. (ii) Following transmission system is included under Phase-I: 1. LILO of 400kV Gooty Madhugiri D/c at Tumkur (Pavagada) Pooling station. 2. LILO of 400kV Bellary Pool Madhugiri D/c (Quad) (both circuits) [KPTCL line] at Tumkur Pooling station.* 3. Tumkur Pooling station - Hiriyur 400 kv D/c. 4. 3x500 MVA, 400/220KV Pooling station at Tumkur. 5. 1x125MVAR bus reactor at 400/220KV Tumkur Pooling station. 6. 220kV Bays(8 Nos) at Tumkur PS for solar interconnection- Implementation as ISTS is subject to resolving regulatory aspects as discussed in the meeting.

(iii) Following would be the transmission system in Phase-II( to be firmed up in the SCPSPSR) 1. Hiriyur Mysore 400 kv D/c line 2. Tumkur Pooling station- Devanhally (KPTCL)** 400kV D/c (Quad) 3. Augmentation of 2x500 MVA, 400/220KV transformer at Tumkur Pooling station 4. Third 400/220 kv, 500 MVA transformer at Madhugiri (new) 5. 1x125MVAR bus reactor (2nd) at Tumkur Pooling Station 6. 1x80 MVAR switchable Line reactor each at Mysore end of Hiriyur- Mysore D/c line 7. 220kV Bays (8 nos.) at Tumkur PS for solar interconnection- Implementation as ISTS is subject to resolving regulatory aspects as discussed in the meeting * KPTCL would complete Bellary pooling station Madhugiri line D/c (Quad) by December, 2016. ** KPTCL will complete establishment of 400/220 kv substation at Devanhally including inter-linking line at 400 kv and 220 kv before Phase-II atultra Mega Solar Park. List of participants Sl. Name Designation Organization No. 1. S D Dubey Member(PS) CEA 2. Pardeep Jindal Director CEA 3. Shivani Sharma Dpty Director CEA 4. Anil EE SRPC 5. Ashok Pal AGM (CTU-Plg.) PGCIL/CTU 6. V. Thiagarajan Addl. GM (CTU-Plg.) PGCIL/CTU 7. Kashish Bhambani Chief Mngr. (SG) PGCIL 8. Nallarasan DGM NLDC, POSOCO 9. T. Kalanithy Asst GM SRLDC, POSOCO, 10. D.B. Suresh SEE (Plg.) KPTCL 11. T V Srinivasa EE KPTCL 12. S.Sumanath Director (Trans.) KPTCL 13. A.J. Hosamani CEE (P&C) KPTCL 14. D. Chetan EE (P&C) KPTCL 15. Divya Prabha EE KPTCL Annex-I

Government of India Ministry of Power Central Electricity Authority PSPA-II Division Sewa Bhawan, R.K. Puram, New Delhi - 110066 No: 51/4/PSPA-II-2015/551 Date: 22-Dec -2015 To COO(CTU-Plg.), Power Grid Corp. of India Ltd., Saudamini, Plot No.-2, Sector 29, Gurgaon - 122001 Subject: In principle approval for Transmission system of Tumkur Ultra Mega Solar Power Park in Karnataka. Reference: PGCIL letter no. C/SG/06/TUMKUR dated 07.12.2015. Madam, 1. PGCIL, vide their letter dated 07.12.2015 has requested to accord in principle approval for Transmission system of Tumkur Ultra Mega Solar Power Park in Karnataka, so that various implementation activities can be taken up, keeping in view the short gestation period of solar generation. 2. A meeting involving participants from POSOCO, PGCIL, KPTCL, SRPC and CEA, was held in CEA on 16.12.2015 (minutes of the meeting enclosed) to discuss the transmission system of Tumkur Ultra Mega Solar Power Park in Karnataka. In the meeting it was decided that in-principle approval may be given to Phase I(1000MW) of the project, as the total scheme is under discussion in 39 th meeting of SCPSPSR to be held on 28-29 December, 2015. 3. In accordance with the discussions held in the meeting on 16-12-2015, we convey inprinciple approval for Phase-I(1000MW) of Tumkur Ultra Mega Solar Power Park: 1. LILO of 400kV Gooty Madhugiri D/c at Tumkur (Pavagada) Pooling station. 2. LILO of 400kV Bellary Pool Madhugiri D/c (Quad) (both circuits) [KPTCL line] at Tumkur Pooling station. 3. Tumkur Pooling station - Hiriyur 400 kv D/c. 1

4. 3x500 MVA, 400/220 kv Pooling station at Tumkur. 5. 1x125MVAR bus reactor at 400/220 kv Tumkur Pooling station. 6. 220kV Bays(8 Nos) ) at Tumkur PS for solar interconnection - Implementation as ISTS is subject to resolving regulatory aspects as discussed in the meeting held on 16.12.2015( Minutes enclosed). 4. The total scheme for evacuation of power from Tumkur project would be finalized in the 39 th meeting of the SCPSPSR as stated above. This issues with the approval of Member (Power System), CEA. Yours faithfully, -sd/- (Pardeep Jindal) Director(PSPA-II) 2