INTRODUCTION WARNING SIGNS AND THEIR MEANINGS

Similar documents
Below, you can see the warning symbols used throughout the manual and their meaning.

Motor Technology Mounting Design Guide

Brushless Torque Motors

Permanent Magnet Synchronous Frameless Torque Motors KSO/H Series

Mounting and Installation Guidelines

Product Manual. Frameless Kit Motors. Product Manual

K Series Kit Motor Reliable and Compact Approach: Build your own high-performance motor

SERVO MOTORS BRUSHLESS SERVO MOTORS ATEX ZONE 2-22 OPERATING INSTRUCTIONS 2016

Brushless Servo Motors

Kollmorgen Frameless Motor Selection Guide

Frameless Permanent Magnet Alternators

Kollmorgen Frameless Motor Selection Guide

LIMITED ANGLE TORQUE MOTORS

K Series Kit Motors. Frameless Kit Motors are the Reliable and Compact Approach to Build Your Own High-Performance Motor. Contact Information:

Data Sheet PM Generator Kit version K535S-4-11 K535S-4-12 K535S-4-14 K535S-4-17 K535S-4-22

Mini-MAG Positioning Products

Omni Series Motors. Applimotion Motors & Actuators TORQUE. Low-Profile Direct Drive Motors for the World s Machines and Robots PRODUCT DATA SHEET

Frameless Torque Motor Series

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

COMPARING SLOTTED vs. SLOTLESS BRUSHLESS DC MOTORS

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

E180 DIAMETER FRAMES

Page 1. Design meeting 18/03/2008. By Mohamed KOUJILI

CHAPTER 3 DESIGN OF THE LIMITED ANGLE BRUSHLESS TORQUE MOTOR

COMPARISON OF PERFORMANCE FEATURES

Features & Benefits. Options & Accessories

Silencer Series Brushless DC Motors

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev

Synchronous motors. Main spindle motors for SINAMICS S120 1FE1 standard type built-in motors Water cooling. 6/86 Siemens NC /2008

SMH High Torque Density

Features & Benefits. Options & Accessories

Features & Benefits. Options & Accessories

Features & Benefits. Options & Accessories

Features & Benefits. Options & Accessories

Features & Benefits. Options & Accessories

Features & Benefits. Options & Accessories

Features & Benefits. Options & Accessories

Silencer Series Brushless DC Motors

E280 DIAMETER FRAMES

ILE2T661PB1A3 brushless dc motor V - Modbus TCP interface - L = 174 mm - 54:1

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

Arm - RX series 170B family

MOONS SM servo motors offer a great combination of Power, Precision and Value:

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

Positioning Systems. Torque Motor Rotary Tables Product Overview and Application Areas

Rotary Series Rotary Series: Direct Drive Precision Stages

ASYNCHRONOUS MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS INSTRUCCIONES DE SERVICIO OPERATING INSTRUCTIONS 2016

Commissioning Manual AC Servo Actuator LynxDrive SIEMENS SIMODRIVE

1326AS Series 460V, Low Inertia, Brushless Servo Motors Product Data

ILE1B661PC1A1 brushless dc motor V - Profibus DP interface - L = 174 mm - 18:1

Lumitester PD-20 Control Kit

PowerLink GW series Eddy Current Dynamometer User Manual

Quantum Series Size 17, 23, 34 and 56 Brushless Servo Motors Frameless and Housed Engineering Guide

High Frequency SineWave Guardian TM

Remy HVH250 Application Manual Remy HVH250 Application Manual

INTRODUCTION GENERAL GUIDELINES ATTACHING THE DRIVE PARTS

Brushless servo motors as replacements for conventional disk armature motors

SERVICE MANUAL OF SERVOMOTORS HD/HR RANGE

Frameless High Torque Motors. Product Brochure

ServoRings TM - integrated rotary tables with high torque servo ring motor, high resolution ring encoder and high accuracy ring bearing

Advantages of a Magnetically Driven Gear Pump By Steven E. Owen, P.E.

FRAMELESS MOTORS AND GEARMOTO

User Manual for the RAMK Rotational Absolute Magnetic Kit Encoder

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

ICH Linear Motors REACH. Installation Guide

AC-synchronous motors. Series LSM-24. Catalogue

Torque motors. (frameless) TGQ Torque (direct) motors

Product Information ECN 425 EQN 437. Absolute Rotary Encoders with Hollow Shaft and Expanding Ring Coupling for Safety-Related Applications

CHAPTER 4 HARDWARE DEVELOPMENT OF DUAL ROTOR RADIAL FLUX PERMANENT MAGNET GENERATOR FOR STAND-ALONE WIND ENERGY SYSTEMS

Service Manual #67. Installation and Service Instructions 6000, 7000 & 8000 Series Magnetically Coupled Pumps

1.4 inch (36mm) Series

MP-Series Integrated Gear Motors

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

Mini-MAG (MMG) Positioning Products Ultra Compact Linear Motor Stages

User Manual. Solar Charge Controller 3KW

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

Linear Motors. 5/14 Installation & Operating Manual MN1800

SLM/SLG SERIES. SLM Series Motors/SLG Series Gearmotors BRUSHLESS AC OR DC SERVO MOTOR / INTEGRATED SERVO GEARMOTOR

Datasheet. Pitch Motor PMSM SP190F8

Commissioning & Maintenance Instructions. for. COBRA linear stepping motors

INTRODUCTION BENEFITS OF USING DDR (DIRECT DRIVE ROTARY) TECHNOLOGY

DC MOTOR MAINTENANCE ALL ELECTRIC LIFT TRUCKS PART NO SRM 294

Typical Technical Requirements for Electrical Machines and Components

1.4 inch (36mm) Series

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1001 SPECIAL ELECTRICAL MACHINES

VEM motors Thurm GmbH

Silencer Series Brushless DC Motors

DRVRMDMOTL Motorized Linear Drive. DRVMDMOTLR Motorized Linear and Rotary Drive. Instruction Manual

TORQUE-MOTORS. as Actuators in Intake and Exhaust System. SONCEBOZ Rue Rosselet-Challandes 5 CH-2605 Sonceboz.

Frameless High Torque Motors. Product Brochure

Actuators are the muscles of robots.

Power in new dimensions

Technical Explanation for Inverters

Arm - TX series 40 family

INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For THREE-PHASE INDUCTION MOTORS TYPE HJN / HJA

MANTECH ELECTRONICS. Stepper Motors. Basics on Stepper Motors I. STEPPER MOTOR SYSTEMS OVERVIEW 2. STEPPING MOTORS

Kollmorgen Frameless Motor Selection Guide

.63 (16mm) Series. High performance slotless brushless motors for military, aerospace, medical/dental, and industrial applications

Mounting & Maintenance Instructions OMT1 & OMT2 Motors

CRYOGENIC MOTORS FOR HERSCHEL/PACS AND JAMES WEBB/MIRI AND NIRSPEC

Transcription:

INTRODUCTION FMI-series frameless motors by Rozum Robotics are designed to provide motion as part of a motion system. Available in a range of sizes (stator dia. 41, 51, 75 mm), FMI motors are suitable for a wide spectrum of applications robotics, industrial machinery, automatic tools, etc. This manual is intended for technicians and engineers who are responsible for integrating the FMI852001 frameless motor into a motion system, as well as operating the motor after integration. The document contains: basic features and components of FMI-series frameless motors a description of the FMI852001 motor supply package specifications and operating conditions of the FMI852001 frameless motor instructions to assemble and mount FMI frameless motors storage and transportation recommendations WARNING SIGNS AND THEIR MEANINGS Below are the warning symbols used throughout the manual and explanations of their meanings. The sign denotes important information that is not directly related to safety, but that the user should be aware of. The sign indicates important safety precautions the user should follow. Rev. 5, valid from Q1 2019 Page 2 14

TABLE OF CONTENTS INTRODUCTION... 2 WARNING SIGNS AND THEIR MEANINGS... 2 1 PRODUCT OVERVIEW... 4 1.1 Basic features and components... 4 1.2 Thermal sensors... 5 1.3 Supply package and transportation... 6 1.4 Additional equipment for building a motion system... 6 Housing... 6 Power supply... 7 Bearing... 7 Controller... 7 Rotor shaft... 7 2 SPECIFICATIONS AND DIMENSIONS... 7 3 MOUNTING REQUIREMENTS... 8 3.1 Mechanical interfaces... 8 3.2 Stator mounting... 8 3.3 Rotor mounting... 9 3.4 Electrical interfaces... 10 Wiring... 10 Protective earthing... 11 4 ASSEMBLY... 11 4.1 Required tools and materials... 11 4.2 Assembly instructions... 12 4.3 Disassembly... 12 5 OPERATING CONDITIONS... 13 6 MAINTENANCE... 13 7 TROUBLESHOOTING... 13 8 STORAGE... 14 Rev. 5, valid from Q1 2019 Page 3 14

1 PRODUCT OVERVIEW 1.1 Basic features and components FMI-series motors are frameless brushless alternating current (AC) motors. Their basic features are as follows: Compact size and low weight High power density and high power-to-weight ratio Simple mounting and assembling An FMI-series frameless motor kit comprises two components a rotor assembly and a stator assembly. Figure 1-1: Rotor and stator assemblies with cable outputs The rotor assembly The rotor assembly (1) is the moving part of the frameless motor. The assembly contains magnets with alternating poles and a support ring (3). The magnets are manufactured from rare-earth metals (neodymium or samarium-cobalt). The rotor can also be supplied assembled with a shaft. Rev. 5, valid from Q1 2019 Page 4 14

The stator assembly The stator assembly (2) is the non-moving component of the FMI frameless motor. By design, the assembly is a 20 mm high lamination stack (4) with coil-supporting teeth. The stack consists of multiple 0.5 mm thick electrical steel plates. For improving thermal conductivity, it is covered with a special polymer compound (5). The stator assembly also includes two cable outputs one for the power cable (7) and the other for the thermal sensor cable (6). The stator can also be supplied with a single cable output comprising both the power and the thermal sensor cables. 1.2 Thermal sensors For overheating protection, FMI-series frameless motors are equipped with a thermal sensor a negative temperature coefficient (NTC) thermistor (model NXFT15). The sensor is integrated into the stator winding and is in direct contact with it. When the thermistor senses increase in the temperature of the stator winding, its resistance decreases. The NTC thermistor provides temperature sensing with accuracy of 0.1 C and has the following characteristics: Resistance at 25 C: 10 kohm Beta constant at 25/85: 3434 K Maximum power: 100 mw Package/case: bead For more information, refer to the manufacturer's documentation for the NXFT15 NTC thermistor. Using cable output (6) (see Figure 1-1), you can connect the thermistor to a controller. The controller uses the thermistor readings to prevent overheating, cutting the motor off in case the maximum temperature setting is exceeded. Figure 1-2: NTC thermistor interface in FMI motors Rev. 5, valid from Q1 2019 Page 5 14

1.3 Supply package and transportation The supply package of an FMI-series frameless motor comprises stator and rotor assemblies. The two assemblies are supplied separately in the same container as shown in Figure 1-3 below. Figure 1-3: An FMI-series frameless motor in a shipping container We recommend using the shipping container for any further transportation of FMI-series motors. Take extra care when unpacking the rotor and the stator to avoid any damage to their components. Do not handle the stator by wiring! 1.4 Additional equipment for building a motion system Building a complete motion system with an FMI frameless motor will require using additional equipment, such as: A housing A power supply A bearing A controller A shaft Housing The additional equipment is usually out of Rozum Robotics supply scope. It is the integrator's responsibility to provide it. The housing should be sufficiently rigid not to deform when you mount the stator in place. The inner diameter of the FMI852001 housing should be such as to comply with the ISO 75 H7 tolerance for the outer diameter of the stator. Rev. 5, valid from Q1 2019 Page 6 14

On the inside, the housing should have a shoulder perpendicular to the stator mounting position. The shoulder is required to provide a clearance between the housing bottom and the stator lamination stack. For the FMI852001 frameless motor, the clearance should be at least 4 mm. For better heat dissipation, you can also cut grooves on the outer surface of the housing. Power supply The power supply should have the same voltage and current ratings as indicated in the motor specifications (see Table 2-1). Bearing It is the entire responsibility of the integrator to provide a bearing to match the application requirements. When selecting a bearing, pay foremost attention to such operating parameters, as speed, expected load, and required service life. Controller You can either order a controller from Rozum Robotics or buy one from a third-party supplier. The recommended type is a PWM controller of the following configuration: FOC sinusoidal control An absolute encoder as a feedback device Output current of 20A continuous Rotor shaft Optionally, Rozum Robotics can supply the FMI852001 frameless motor pre-assembled with a shaft. In other cases, make sure that the outer diameter of the selected shaft complies with the ISO 38 H7 tolerance as specified for the inner rotor diameter. 2 SPECIFICATIONS AND DIMENSIONS Table 2-1 lists major technical specifications of FMI852001 frameless motors. Rev. 5, valid from Q1 2019 Page 7 14

Table 2-1: Technical specifications of the FMI852001 frameless motor Parameter Value Unit of measurement Mechanical Weight 455 g Rotor inertia 0.35 kg/cm² Stator diameter 75 mm Electrical Winding type Supply voltage 48 V RMS current 9 A Torque constant at 20 С, Kt 100 mn m/a Motor constant at 20 С 226 mn m/ W Speed constant, Kv 100 RPM/V Terminal resistance at 20 С 0.13 Ω Terminal inductance 155 μh Number of pole pairs 10 Performance Power 405 W Maximum efficiency 90 % Rated torque 0.9 N m Peak torque 2.6 N m Rated speed 4 300 RPM No load speed 4 800 RPM 3 MOUNTING REQUIREMENTS 3.1 Mechanical interfaces Y For safe operation, it is essential to provide an air gap of at least 0.3 mm between the rotor and the stator. For the purpose, make sure to use 0.2 mm thick shim (e.g., made from mylar) when assembling the rotor with the stator (Section 4.2). 3.2 Stator mounting The preferred method for mounting the stator is bonding. We recommend using the Loctite 648 or 638 adhesive. Before applying the adhesive, make sure to clean the bonding surface (see Figure 3-2) with a suitable cleaning agent (e.g., acetone). Rev. 5, valid from Q1 2019 Page 8 14

Figure 3-1: The bonding surface of a stator 3.3 Rotor mounting A rotor can be mounted using one of the following two methods axial clamping or bonding. Axial clamping The choice of the mounting method will depend on the application system design. Some of the possible considerations include heat transfer, stiffness, integration methods, and maintenance. This mounting method requires using a clamping ring. You need to position the clamping ring on the clamping surface (see Figure 3-2) and press it against the rotor ring. The clamping ring should not contact the rotor magnets to avoid any damage to them. Bonding The recommended adhesive for bonding a stator is Loctite 648 or 638. Before applying the adhesive, make sure to clean the bonding surface with a suitable cleaning agent (e.g., acetone). Rev. 5, valid from Q1 2019 Page 9 14

Figure 3-2: The mounting surfaces of a rotor To avoid demagnetizing, never apply temperature above 70 C when curing the adhesive. 3.4 Electrical interfaces Wiring The wiring of FMI frameless motors comprises: The wiring of FMI-series frameless motors comprises: a 3-phase power cable of Y-configuration (black) a 2-wire temperature sensor cable (blue and brown) To provide electrical integration of the frameless motor into your application, use the wiring scheme in Figure 3-3. Before starting wiring works, make sure to disconnect the motor and the application from power supply. Rev. 5, valid from Q1 2019 Page 10 14

Protective earthing Figure 3-3: The wiring scheme for integrating FMI frameless motors It is the responsibility of the integrator to provide protective earthing of the motor housing. The protective earthing should comply with the following minimum requirements: Its current capacity should be at least equal to the current capacity of the motor wiring. The protective earthing wire should have the standard yellow/green insulation. Its voltage rating should correspond to the supply voltage of the motor winding as indicated in the specification (see Table 2-1). You can either bundle the protective earthing wire with the motor wiring or run it separately, if your operating conditions require so. 4 ASSEMBLY 4.1 Required tools and materials To install the stator and the rotor into a housing, you will need the following tools and materials: an installation tool as appropriate for your purposes a 0.2 mm thick shim (e.g., made from mylar) To avoid any damage to the rotor, we recommend using non-magnetic tools. For housing dimensions and other requirements, see the dimension drawings that are available for downloading at https://rozum.com/frameless-documentation/. Rev. 5, valid from Q1 2019 Page 11 14

4.2 Assembly instructions Below is a generic sequence of steps as required to install the rotor and the stator into a housing. Handle the components of the frameless motor with care, especially the rotor, because its magnets are sensitive to mechanical shock. Magnetic-sensitive objects, such as banking cards, pacemakers, or other magnetic information carriers, should be kept away at a distance of 1m from the rotor. Step 1: Position your selected housing (see recommendations in Section 1.4) on a stable surface and fix it in place to prevent any sudden movements. Step 2: Place the stator into the housing and secure it by bonding (see Section 3.2). Step 3: Prepare the rotor assembly for installation. To do that, slide the rotor ring onto the rotor shaft and secure it either by clamping or by bonding (see Section 3.3). Rare-earth magnets are brittle and chip easily. Therefore, take extra care when sliding the rotor ring onto the shaft and handling the assembly. Step 4: Inside the stator ring, install a shim to prepare for fitting the rotor assembly. Step 5: Lower the rotor assembly slowly and smoothly along the axis line to position it inside the stator ring. During installation, the stator and rotor are exposed to strong attraction forces in axial and radial directions. For safe insertion, use special tooling that can provide smooth and gradual lowering of the rotor assembly along the axis line. Step 6: Remove the shims. Now, the motor is ready for further integration into your motion system. To complete the integration, you will need the additional equipment as listed in Section 1.4. The exact integration procedure will depend on the design of your system. As a pre-commissioning test, you can rotate the motor manually to make sure it moves without stalling. 4.3 Disassembly A generic disassembly practice is to follow the reverse order of the assembly sequence as described in Section 4.2. Rev. 5, valid from Q1 2019 Page 12 14

5 OPERATING CONDITIONS Make sure that the location where the frameless motor is to be operated has a well-functioning exhaust system and is free from metal dust and debris. Other environmental specifications applicable to operation of FMI-series frameless motors are as listed in Table 5-1. Table 5-1: Environmental specifications Parameter Operating temperature 0 to 35 C Operating humidity Altitude Atmosphere Specifications 80% max at 25 C (90% at 20 C) Not higher than 1,000 m above the sea Not suitable for use in explosive or hazardous atmospheres Avoid exposing the motor to any environmental conditions outside of the listed specifications as this can cause damage to it. 6 MAINTENANCE FMI-series frameless motors are essentially maintenance-free. However, it is advisable to check the motor regularly for the following: excessive or abnormal motor heating excessive motor vibrations loose couplings burning smells accumulation of debris, etc. When working with the rotor magnets, only non-ferrous tools are admissible. 7 TROUBLESHOOTING Table 7-1 lists the most common problems that can occur during operation of FMI-series frameless motors and their possible causes. Table 7-1: Most common operation problems and their causes Problem You cannot turn the frameless motor by hand during the precommissioning test. Possible cause There is a mechanical blockage. Non-insulated parts of the two motor wires contact each other. Rev. 5, valid from Q1 2019 Page 13 14

You have trouble starting the frameless motor. The motor generates excessive heat. Excessive noise. Broken wire either inside the motor or outside it. Incorrect installation of the rotor. Excessive load and operation outside the specifications (Table 2-1). Defect of the motor winding. To know the exact cause for sure, check operation of the motor at no load. If the motor is overheating even at no load, the cause is a winding defect. Otherwise, adjust the operation mode in accordance with the motor specifications. Bearing defect. Operation outside the motor specifications (Table 2-1). Only qualified service personnel can perform repair works. 8 STORAGE Prior to commissioning, it is advisable to store frameless motors in their shipping containers. Make sure to comply with the following storage requirements: For storing, choose a location with a controlled environment Storage temperature: +5 C to +40 C Storage humidity: 80% max at 25 C (90% at 20 C) Protect motor components from direct contact with magnetic materials or particles (e.g., iron chips, dust, etc.) The maximum storage period is 10 years, provided the storage container is protected from humidity with silica gel. Rev. 5, valid from Q1 2019 Page 14 14