Halton PRL Plenum for grilles

Similar documents
TRH - Plenum for diffusers. Halton TRH. Plenum for diffusers

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

TBV - Terminal Unit. Halton TBV. Terminal Unit

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

DAC - Conical Diffuser. Halton DAC. Conical diffuser

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

WDD/WSD - Grille. Halton WDD/WSD. Universal Grille

TCM - Conical Ceiling Diffuser. Halton TCM. Conical Ceiling Diffuser

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

HDF - Exhaust Grille. Halton HDF. Exhaust Grille

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

Casing Hot galvanised steel / Option: stainless steel EN (AISI316L) Reheat coil EN (AISI 304)

ULA - Valve. Halton ULA. Valve

HME SINGLE DUCT CABIN UNIT CABIN UNITS HME. Sound attenuator and balancing box

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

BOX - Airflow management unit BOX. Airflow management unit. Solution. Options & Accessories

Ceiling swirl diffusers with perforated face plate

Halton Rex 600 RE6 - Adaptable active chilled beam

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

DHL - HEPA terminal filter diffuser DHL. HEPA terminal filter diffuser

PTS - Single-Blade Damper. Halton PTS. Single-Blade Damper

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

CADENZA. Sound attenuator with tapered acoustic baffles for rectangular ducts QUICK FACTS

Extract-air grille with ATK plenum box

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Parts and characteristics

GDD - Supply Grille. Halton GDD. Supply Grille

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

Ceiling swirl diffusers

CAV controllers Type RN

VARYCONTROL VAV Dual Duct Terminal Boxes

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

SINGLE DUCT TERMINAL UNITS

For installation into ductwork

Type VSD35. Nominal length up to 1500 mm: one spigot

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

VOLUME CONTROL / REGULATING DAMPERS

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Small Format Circular Diffusers. Small format circular diffuse

VAV controller. TROX Auranor Norge AS. Telephone Fax

Plenum box ATTD TECHNICAL DATA

KWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology

Exhaust air diffuser HPKH + Plenum box ATTS

SERENO

Plenum boxes. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.

Rectangular inlet air diffuser

SEMI RIGID THE PROFESSIONALS CHOICE

Table of Contents. Page 2 Page 2 Page 2 Page 2 Page 3 Page 3 Page 3 Page 3 Page 3 Page 4 Page 4 Page 4 Page 5 Page 5 Page 5

INSTRUCTION MANUAL. AMS 4000 One Piece. Negative Pressure Unit (AMS-4000 NPU 230V)

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Stainless Steel Chimneys Ducts and Fittings for Air Conditioning & Ventilation

Supply air diffusers RHKH and RHOH / Supply air units RHKB/RHOB (=RHKH/RHOH+ATTD)

INSTRUCTION MANUAL. AMS 1500 One Piece. Negative Pressure Unit (AMS-1500 NPU 230V)

AL-Maraj Central A/C Systems Accessories Mfg Co.

Variable Air Volume Dampers

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Zest Iris Duct Dampers

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

DIR. VARIZON Displacement unit with adjustable spread pattern. Quick guide

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Nozzle diffuser DYRH / Supply air unit DYRB (=DYRH+ATTD)

Ceiling swirl diffusers with perforated face plate

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

Supply air diffusers RPPH and ROPH / Supply air units RPPA/ROPA (=RPPH/ROPH+ATTD)

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Systempac. Fan Coil Unit / Acoustic Flex / Diffuser System Package. Systempac. January Features and Design Guide

Linear Slot Diffusers Model Slot 20 & Model Slot 25

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

Duct filter units. Duct HEPA filter units AKF

Zero Leakage Isolation Damper

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

Ceiling swirl diffusers

TD-SILENT Series (160 to 1000 models)

Apartment ventilation

Mechanical mixing box MBM

Transcription:

Plenum for grilles Plenum for connecting supply/exhaust grille to ductwork Ensures proper function of the supply air grille Robust, airtight construction with aesthetically pleasing design Flexibility for grille installation due to telescopic collar Detachable measurement (only supply air) and airflow rate adjustment module Effective sound attenuation Access for ductwork cleaning Material Part Material Note Casing Collar Galvanised steel Galvanised steel Attenuation material Mineral wool Alternatively polyester fibre Spigot with gasket Galvanised steel Gasket rubber compound Measurement and adjustment module (MSM/MEM) Body: Aluminium Plate: Galvanised steel Brackets: Galvanised steel Plastic parts: Polypropylene (PP) Spindle: Stainless steel 1

Dimensions NS A B C D E F G H L S 200x100 208 201 198 124 92..150 9 42 101 230 63 300x100 224 301 226 159 92..150 9 33 101 330 63 400x100 260 401 226 159 92..150 9 51 101 430 63 500x100 287 501 276 199 92..150 9 44 101 530 63 300x150 287 301 276 199 92..150 9 44 151 330 63 400x150 360 401 330 249 92..150 9 56 151 430 63 500x150 360 501 330 249 92..150 9 56 151 530 63 800x150 413 801 382 314 92..150 9 50 151 830 63 400x200 360 401 330 249 92..150 9 56 201 430 63 500x200 394 501 382 314 92..150 9 40 201 530 63 800x200 413 801 382 314 92..150 9 50 201 830 63 No special dimensions possible. Accessories Accessory Code Description Airflow measurement and Adjustment and measurement MSM adjustment unit module for supply airflow rate Airflow adjustment unit MEM Adjustment module for exhaust airflow rate Sound attenuation IN Internal sound attenuation material of mineral wool or polyester fibre 2

Product models Model PRL/A PRL/B PRL/C PRL/D PRL/E PRL/F PRL/G PRL/H PRL/I Description Supply air with adjustment and measurement module (MSM) and option for internal sound attenuation, duct connection from left or right Supply air with adjustment and measurement module (MSM) and option for internal sound attenuation, duct connection from back Supply air with adjustment and measurement module (MSM) and option for internal sound attenuation, duct connection from top or bottom Exhaust air with adjustment module (MEM) and option for internal sound attenuation, duct connection from left or right Exhaust air with adjustment module (MEM) and option for internal sound attenuation, duct connection from back Exhaust air with adjustment module (MEM) and option for internal sound attenuation, duct connection from top or bottom Without adjustment and measurement module and internal sound attenuation, duct connection from left or right Without adjustment and measurement module and internal sound attenuation, duct connection from back Without adjustment and measurement module and internal sound attenuation, duct connection from top or bottom Duct connections /A, PRL/D or PRL/G (side connection) 3

/B, PRL/E or PRL/H (back connection) /C, PRL/F or PRL/I (top/bottom connection) 4

Function balancing plenum equalises the airflow by reducing the flow velocity. Air is spread evenly into the grille, ensuring proper function. A range of grilles can be connected to the distribution duct with the aid of a, improving their characteristics considerably. The plenum also attenuates duct noise. can also be used as an exhaust unit. 5

Installation is connected to the duct with a spigot equipped with a gasket. The duct connection can be located on the side, above/below or behind the plenum. Due to the symmetrical structure of the, connections can be made in a number of different ways: by turning the plenum right or left, or by rotating, from above or below. The telescopic collar of the plenum permits mounting into walls of thickness 90...150 mm. The recommended safety distance upstream of the plenum in supply installations is minimum 3D. Dimensions for installation hole are (L1+5mm) x (K+5mm). 6

Adjustment The supply flow rate is determined by using the measurement and adjustment module MSM. The tubes and control spindle are passed through the grille. Measure the differential pressure with a manometer. The flow rate is calculated using the formula below. Adjust the airflow rate by rotating the control spindle until the desired setting is achieved. Lock the damper position with a screw. Replace the tubes and spindle into the plenum. Servicing Detach the grille and the perforated plate of the telescopic collar. Detach the measurement and adjustment module by pulling gently from the casing (not from the control spindle or measurement tubes). Wipe the parts with a damp cloth, instead of immersing in water. The measurement and adjustment module is remounted by pushing the body until it meets the stopper. The sound attenuation material within the plenum can also be removed (the material is washable), to enable cleaning of the inner side of the plenum. The material is detached by releasing the retaining brackets, which are replaced after washing. Replace the grille after cleaning. Technical specification The balancing plenum for grilles shall be made of galvanised steel and shall have a robust and airtight construction. Airflow rate measurement and adjustment module shall be available for supply application. The measurement and adjustment module shall be adjustable without opening the grille. The balancing plenum shall have a spigot with integral gasket for airtight duct connection and a plug for ductwork pressure testing. The plenum shall have options for duct connection on the side, back or top. The balancing plenum shall attenuate duct noise. The sound attenuation material shall be made of mineral wool or polyester fibre with a washable surface. 7

Product code PRL/S-W-H-D S = Model A Supply inlet (Left-Right connection) B Supply inlet (Back connection) C Supply inlet (Top/Bottom connection) D Exhaust outlet (Left-Right connection) E Exhaust outlet (Back connection) F Exhaust outlet (Top/Bottom connection) G No accessories (Left - Right connection) H No accessories (Back connection) I No accessories (Top/Bottom) connection W = Width of grille connection 200, 300, 400, 500, 600, 800 H = Height of grille connection 100, 150, 200 D = Connection size 125, 160, 200, 250, 315 Other options and accessories AT = Sound attenuation material P Polyester fibre W Mineral wool NA No sound attenuation OM = Measurement/adjustment modul YS MSM installed (supply) YE MEM installed (exhaust) NA No measurement or adjustment module ZT = Tailored product N No Code example PRL/A-200-100-125, AT=P, OM=YS, ZT=N 8