Installation Instructions

Similar documents
BD-1600 Balancing/Zone Control Damper

M9000-3xx Series Weather Shield Enclosures

M Valve Actuator Weather Shield Kit

RA-2000 Airflow Measuring System

M x Series Valve Linkage Kits

AD-1250 Airflow Measuring Station

M9300 Series Potentiometer Kits

M Remote Mounting Kit

M9300 Series Switch Kits

D-3240 Series Pneumatic Piston Actuators

V-2410 Three-Way Multipurpose Solenoid Air Valve

M9116, M9124, and M9132 Series Electric Non-spring Return Actuators

R-317 Air Flow Controller

V-9502 Series Pneumatic Valve Actuator Positioners

M9220-xxx-3 Electric Spring Return Actuators

C-5230 Pneumatic Signal Limiter

VA-7450 Series. Electric Valve Actuators

M x Series Valve Linkage Kits

M9109 Series Electric Non-spring Return Actuators

TM-11x1 Series Room Temperature Module

M Ball Valve Linkage Kit

VD-1600 Series Volume Control Dampers

M x Cast Iron Flanged Valve Linkage Kit for Mounting a Single M9000 Series Electric Actuator

M Remote Mounting Kit

M x Series Valve Linkage Kits

M9104-AGP-2S Series Electric Non-Spring Return Actuator with Pressure Sensor for VAV Applications Part No , Rev. B

M x Series Cast Iron Flanged Valve Linkage Kit for Tandem Mounting of M9000 Series Electric Actuators

M9106-xGx-2 Series Electric Non-Spring Return Actuators

M9102-AGA-3S and M9104-xGA-3S Series Electric Non-Spring Return Actuators

RD-2000 Round Control Dampers

M Remote Mounting Kit

A11 Series Low Temperature Cutout Control

M9106-AGx-2N0x Series Electric Non-Spring Return Actuators

A25 Series Warm Air Control with Manual Reset

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators

SD-1250 and SD-1600 Series Smoke Dampers

M x Series Cast Iron Flanged Valve Linkage Kit for M9000 Series Electric Actuators

M Damper Mount Linkage Kit Installation. Item Description Quantity Item Description Quantity Nuts 2

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

ID-141x 12-Gauge Hat Channel Industrial Damper

N-1001 Economizer Logic Network

Fan Relay Board (FRBii) Assembly

M9208-AGx-x Series On/Off and Floating Point Electric Spring Return Actuators

A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories

AD-1251 Probe with Differential Pressure Transducer

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

RM-1200 Slim Round Control Damper

P70, P72, and P170 Series Controls for High Pressure Applications

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

PC-125x Counter-Balanced Backdraft Damper

M9210-xxx-3 Electric Spring Return Actuators

M9203-Bxx-2(Z) Series On/Off Electric Spring Return Actuators

VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators

VA-720x Electric Valve Actuator

VA-8020 Floating Valve Actuator

VA9905 Actuator and VG1600 Series Six-Way Valves

TE-6001 Hardware Assemblies for TE-6000 Temperature Elements

Damper Accessory Kits

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

VG7000 Series Bronze Control Valves

V46 and V47. Repair Parts and Service Instructions. Applications. Adjustments. Installation Guidelines

M9216 Series Electric Spring Return Actuators

EDA-8100 Electric Damper Actuator

VA2202-xxx-2 Series Electric Spring Return Valve Actuators

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

PP1 Series Piping Packages for VG1000 Series Ball Valves

Damper Actuator Installation

M9206-GGx-2S Series Proportional Electric Spring Return Actuators

D-4070 Two Stage Pneumatic Actuator

AM-676, AM , AM-690-R, AM-692, AM-693-R, AM-762, and AM-763

Mounting Installation Instructions ZG-JSL(A)

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

M9300 Series Electric Non-Spring Return Actuators

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

AV-8020 Series Floating Control Actuated Valve

M9208-xxx-x Series Electric Spring Return Actuators

M9102-AGA-2S and M9104-xGA-2S Series Electric Non-Spring Return Actuators

ATP-2040 Electric Damper Actuator/Transmitter

Operating the Network Control Module (NCM) Battery Charger/Tester

VA-715x Electric Valve Actuator

Introduction to Johnson Controls Dampers

TE-6300 Series Temperature Sensors

P1000 Series Pressure Independent Valves

S-2300 Pneumatic Selector Switch

TE-6300 Series Temperature Sensors

RPM1600 Series Room Pressure Monitors

VA2202-xxx-2 Series Electric Spring Return Valve Actuators

Installation Instructions. Applications. Installation. Part No , Rev. Issued May 9, 2011

Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty. Feature and Benefits

P78 Series Controls for Dual Pressure and Hazardous Location Applications

VA9104-xGA-3S Series Electric Non-Spring Return Valve Actuators

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

V43xx and V243xx Series Repair Parts Kits

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications

Transcription:

34-636- 2286, Rev. C (barcode for factory use only) M9000-400 Jackshaft Linkage Kit Installation Instructions M9000-400 Part No. 34-636-2286, Rev. C Issued June 2017 Applications Refer to the QuickLIT website for the most up-to-date version of this document. The M9000-400 Jackshaft Linkage Kit is designed to simplify the installation of select Johnson Controls actuators onto dampers with jackshafts. The open-ended design enables the linkage to clamp onto a jackshaft without requiring access to the ends of the jackshaft. The maximum jackshaft diameter that can be accommodated is 1.05 in. (26.7 mm). A reversible metal clamp insert accommodates 1/2 and 3/4 in. (13 and 19 mm) jackshafts. For tight installation spaces, the actuator anti-rotation plate enables actuator installations to be rotated 90 degrees. Use the M9000-400 Jackshaft Linkage Kit: on a simple damper and jackshaft. on a jackshaft that connects multiple sections of damper together. to allow damper operation from either side of the HVAC equipment. when dampers are recessed into walls or equipment and the side of the damper is not accessible for control shaft mounting. IMPORTANT: Do not apply actuators in excess of 90 lb in (10 N m) rated torque on a 1/2 in. (13 mm) jackshaft. Installation Choose an actuator from one of the series listed in Table 1. There is a torque reduction associated with use of the M9000-400. Table 1: Torque Reduction by Actuator Series Actuator Series Resultant Torque M9108 Series 68 lb in (7.7 N m) M9116 Series 131 lb in (14.8 N m) M9124 Series 195 lb in (22.0 N m) M9208 Series 68 lb in (7.7 N m) M9220 Series 164 lb in (18.5 N m) M9308 Series 68 lb in (7.7 N m) M9310 Series 87 lb in (9.8 N m) M9320 Series 164 lb in (18.5 N m) M9335 Series 284 lb in (32.1 N m) 1

There are three basic locations to mount the kit: Parallel to the damper inside air stream (Figure 15) Perpendicular to the damper inside air stream (Figure 17) Outside the air stream (no illustration available) When mounting, check that there is at least 3 in. (76 mm) of space between the damper blade and the jackshaft. Also check that the mounting location allows for the 4-3/4 in. (121 mm) width of the linkage. To install the M9000-400 Jackshaft Linkage Kit: 1. Set the jackshaft clamp to the correct size for the jackshaft. Figure 1: Setting the Jackshaft Clamp 2. Insert the retainer. Figure 2: Inserting the Retainer 2

3. Remove two screws and adjust the anti-rotation bracket length to fit the type of actuator used. See Figure 3 and Table 2. Figure 3: Adjusting the Anti-Rotation Bracket Length Table 2: Hole Set by Actuator Series Actuator Series Hole Set M9108 Series 3 M9116 Series 3 M9124 Series 3 M9208 Series 1 M9220 Series 1 M9308 Series 5 M9310 Series 5 M9320 Series 3 M9335 Series 3 3

4. Move the linkage to the side shown for proper rotation direction. Figure 4: Setting for Rotation Direction 5. Place the linkage assembly onto the jackshaft. Figure 5: Placing the Linkage Assembly onto the Jackshaft 4

6. Set the clamp against the jackshaft. Figure 6: Setting the Clamp against the Jackshaft 7. Install the V-bolt but do not tighten it. Figure 7: Installing the V-Bolt 5

8. Secure the V-bolt to the shaft. Figure 8: Securing the V-Bolt to the Shaft 9. With the linkage in place, secure the linkage to the damper frame with the anti-rotation L-bracket. Secure the adapter plate to the anti-rotation L-bracket with the flat-head screws. See Figure 9. Note: The anti-rotation L-bracket can rotate to any angle. If necessary, use the additional adapter plate for smaller bearings. Figure 9: Installing the Anti-Rotation L-Bracket 6

10. Secure the anti-rotation L-bracket (with or without the adapter plate) to the shaft bearing bracket, using the self-tapping screws. Figure 10: Securing the Anti-Rotation L-Bracket 11. Secure the adapter plate to the standoff. Figure 11: Securing the Adapter Plate 7

12. With the anti-rotation L-bracket attached, slide the linkage until the tab on the anti-rotation L-bracket aligns with the slot in the linkage. Figure 12: Aligning the Tab on the Anti-Rotation L-Bracket with the Slot in the Linkage 13. Place the actuator onto the linkage assembly. Figure 13: Placing the Actuator onto the Linkage Assembly 8

14. Tighten the hex nuts on the clamp to secure the actuator in place. Tighten the hex nuts to a torque of 100 to 125 lb in (11 to 14 N m). Figure 14: Tightening the Hex Nuts on the Clamp Figure 15: Complete Installation; Parallel to Damper 9

Figure 16: Rotating the Actuator Anti-Rotation Plate Figure 17: Complete Installation; Perpendicular to Damper Repair Information The M9000-400 Jackshaft Linkage Kit has no components that require routine scheduled maintenance. If the M9000-400 Jackshaft Linkage Kit fails to operate within its specifications, replace the unit. For a replacement jackshaft linkage kit, contact the nearest Johnson Controls representative. 10

European Single Point of Contact: NA/SA Single Point of Contact: APAC Single Point of Contact: JOHNSON CONTROLS WESTENDHOF 3 45143 ESSEN GERMANY JOHNSON CONTROLS 507 E MICHIGAN ST MILWAUKEE WI 53202 USA JOHNSON CONTROLS C/O CONTROLS PRODUCT MANAGEMENT NO. 22 BLOCK D NEW DISTRICT WUXI JIANGSU PROVINCE 214142 CHINA Metasys and Johnson Controls are registered trademarks of Johnson Controls. All other marks herein are the marks of their respective owners. 2017 Johnson Controls. Building Technologies & Solutions 507 E. Michigan Street, Milwaukee, WI 53202 Published in U.S.A. 11 www.johnsoncontrols.com