VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

Similar documents
VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VKA/VKAS. Circular duct fans CIRCULAR DUCT FANS

VKA/VKAS. Circular duct fans CIRCULAR DUCT FANS

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

NEW! Mounting clamp Guard grille Back draft shutter Circular duct silencer

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller.

VKA VKAS VKA VKAS. Mounting clamp Guard grille Back draft shutter Circular duct silencer

valymui. - - Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

IN-LINE CENTRIFUGAL DUCT FANS VT Series

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

VSA. Roof fans. Dachventilatoren. Roof fans

KF T120. Kitchen fans. Wentylatory kuchenne KITCHEN FANS

VKA VKAS VKA VKAS. Mounting clamp Guard grille Back draft shutter Circular duct silencer

CENTRIFUGAL IN-LINE FANS VENT Series

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

BOX BLB Centrifugal Box Fan

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

CA V0 E RANGE In-line centrifugal fans in self-extinguishing plastic

NCF fans 50 Hz. Protection class IP 55

Single-inlet centrifugal fans

Short casing. Long casing (L version) Commercial premises

Sabre Plate Mounted Sickle Fans (VSP)

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

Square Mixed Flow Fans (MFQ)

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

HIT CENTRIFUGAL IN-LINE FANS ACCESSORIES APPLICATION FEATURES & BENEFITS CONSTRUCTION

Plate mounted axial flow fans HXBR / HXTR Series

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

CYLINDRICAL CASED AXIAL FLOW FANS

Unobox units with backward curved centrifugal impellers

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

Thermo fans. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K ASF/KB. Flexible connection

KV sileo 100 M. Circular duct fans. Circular duct fans

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

ACOUSTIC CABINET FANS CVB / CVT Series

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

Wall mounted fan

AC Commercial Fans Edition. ErP ready

Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

ACCESSORIES FOR DUCT FANS

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

TGT Series Adjustable Pitch Fans

ACOUSTIC CABINET FANS CVAB / CVAT Series

supplied in Form (B) configuration. Airflow over Impeller- Motor.

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

ErP METAL TUBE FANS - ROPERA EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE INSTALLATION

CGT Series Adjustable Pitch Fans

HIT CENTRIFUGAL IN-LINE FANS ACCESSORIES APPLICATION FEATURES & BENEFITS CONSTRUCTION

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

TWINFLOW STDR Product Brochure

TGT Series Adjustable Pitch Fans

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

NEW Acoustic In-Line Fans (ACQ)

CGT Series Adjustable Pitch Fans

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

CK, LPK, LPKB. Duct fans with circular connection.

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Mixed Flow Roof Fans (RMH)

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

VSA. Roof fans. Tourelles. Dachventilatoren. Крышные вентиляторы. Roof fans

VORTICENT C E RANGE Centrifugal fans

NCF 60 Hz. Protection class IP 55

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

Mixed Flow Roof Fans (RMH)

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

NEW Slimpak EC Box Fan (SLPT EC)

DIRECT-AIR ILB / ILT Series Rectangular duct fans

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

Inside Front cover White

HIGH-POWERED VENTILATORS

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

Transcription:

Application Features Power supply Circular duct fans are used in low-to medium-pressure ducted systems. Fans are suitable for air supply or exhaust of residential buildings, warehouses, bathrooms, lavatories, auxiliary premises and other premises where the heat recovery is not required, also as boost fans in ventilation systems. Diameter - 1 mm to 315 mm; Airflow up to 145 m 3 /h; Easily mounted in any position; Backward- impeller; Low ambient temperatures; Cost-effective. 23V/5Hz/1f. Temperature range - O C to 5 O C. Sizes 1, 125, 15, 1,, 25, 315. Construction Installation Speed control options Casing: galvanized sheet steel; Fan: centrifugal impeller and external rotor motor; Motor protection with built-in thermal-contact; Motor protection class: IP44; Terminal box protection class: IP55. Mounting with ducts: Spiro, flexible aluminium or plastic. Mounting bracket LAV is included; Device can only be used indoors; Not suitable for polluted air or volatile and explosive gases. Electronic voltage controller (phase cut); Voltage controlled speed controller. VKAP 1 MD/LD 3. Product version Motor power level (M higher power level, L lower power level) Diameter Product name Accessories Single phase speed controller Single phase speed controller Mounting clamp Guard grille Back draft shutter Circular duct silencer TGRV p. 127 ETY p. 128 AP p. 19 AGO p. 181 RSK p. 177 MUTE p. 174 The company reserves the right to make changes of technical data without prior notice

Type Dimensions [mm] B C ød ød E VKAP 1 MD/LD 3. 189 152 244 1 287 VKAP 125 MD/LD 3. 182 143 243 125 286 VKAP 15 LD 3. 217 166 344 15 387 VKAP 1 MD 3. 189 143 244 1 287 VKAP 1 LD 3. 217 166 344 1 387 VKAP MD 3. 219 167 344 387 VKAP LD 3. 231 179 344 387 VKAP 25 MD 3. 223 1 344 25 387 VKAP 25 LD 3. 23 167 344 25 387 VKAP 315 MD 3. 243 175 2 315 444 VKAP 315 LD 3. 256 188 2 315 444 Type Accessories TGRV ETY AP AGO RSK MUTE FD FDI EKA AVS AVA VKAP 1 MD/LD 3. 1,5 1,5 1 1 1 1 1 1 1 1 1 VKAP 125 MD/LD 3. 1,5 1,5 125 125 125 125 125 125 125 125 125 VKAP 15 LD 3. 1,5 1,5 15 15 15 - - - - - - VKAP 1 MD 3. 1,5 1,5 1 1 1 1 1 1 1 1 1 VKAP 1 LD 3. 1,5 1,5 1 1 1 1 1 1 1 1 1 VKAP MD 3. 1,5 1,5 VKAP LD 3. 1,5 1,5 VKAP 25 MD 3. 1,5 1,5 25 25 25 25 25 25 25 25 25 VKAP 25 LD 3. 1,5 1,5 25 25 25 25 25 25 25 25 25 VKAP 315 MD 3. 1,5 1,5 315 315 315 315 315 315 315 315 315 VKAP 315 LD 3. 1,5 1,5 315 315 315 315 315 315 315 315 315 Filter box Filter box Electric duct heater Heating coil Duct water cooler FD p. 169 FDI p. 167 EKA p. 139 AVS p. 148 AVA p. 156 The company reserves the right to make changes of technical data without prior notice 21

VKAP 1 MD 3. VKAP 1 LD 3. 7 5 3 1 1 1 1 8 1 MD 3. Lwa total, Lwa, 8V 1V 1V 17V 23V 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 61 45 57 52 56 51 31 Outlet 61 44 58 52 55 5 39 3 Surrounding 46 26 27 36 44 41 3 23 Measured at m 3 /h, 62 Pa 8V 1V 1V 17V 23V 1 LD 3. Lwa total, Lwa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 7 53 58 66 65 58 47 Outlet 71 54 61 67 66 58 48 Surrounding 61 34 58 44 55 54 47 37 Measured at 257 m 3 /h, 14 Pa VKAP 125 MD 3. 5 8V 1V 1V 17V 3 23V 1 125 MD 3. Lwa total, Lwa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 59 43 52 53 54 51 41 33 Outlet 42 53 54 54 52 42 34 Surrounding 45 21 3 36 42 29 18 Measured at 191 m 3 /h, 83 Pa 22 The fan characteristic curves were determined in accordance with EN ISO 581. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. The company reserves the right to make changes of technical data without prior notice

VKAP 125 LD 3. VKAP 15 LD 3. 1 1 1 8 18 1 1 1 1 8 125 LD 3. Lwa total, Lwa, 8V 1V 1V 17V 23V 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 69 5 54 63 65 64 56 47 Outlet 68 49 53 61 64 63 55 45 Surrounding 56 28 29 45 53 52 44 35 Measured at 28 m 3 /h, 14 Pa 15 LD 3. Lwa total, Lwa, 8V 1V 1V 17V 23V 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 74 51 66 67 71 62 61 53 Outlet 75 52 67 68 72 64 63 5 Surrounding 62 3 49 51 52 5 36 Measured at 595 m 3 /h, 112 Pa VKAP 1 MD 3. 1 1 1 8V 1V 1V 17V 8 23V 1 MD 3. Lwa total, Lwa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 68 47 5 56 64 63 61 49 Outlet 69 48 52 57 65 64 63 51 Surrounding 56 26 27 53 51 5 35 Measured at 318 m 3 /h, 13 Pa The fan characteristic curves were determined in accordance with EN ISO 581. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. The company reserves the right to make changes of technical data without prior notice 23

VKAP 1 LD 3. 1 1 1 8V 1V 1V 1 17V 8 23V 1 LD 3. Lwa total, Lwa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 74 52 67 68 71 62 62 52 Outlet 75 52 68 68 72 64 63 51 Surrounding 61 31 49 52 59 52 51 36 Measured at 685 m 3 /h, 14 Pa Electrical data Phase/Votage/Frequency [V/Hz] ~1, 23/5 ~1, 23/5 ~1, 23/5 ~1, 23/5 ~1, 23/5 ~1, 23/5 ~1, 23/5 Max. power consumption [kw],74,74,74,74,13,74,13 Max. current [A],3,31,3,31,5,31,5 Capacitor [µf] 2 2 2 2 2 2 2 Wiring diagram No. 1 No. 1 No. 1 No. 1 No. 1 No. 1 No. 1 Fan speed controller Technical data Max. airflow [m 3 /h] 281 379 37 421 773 451 866 Fan impeler speed [min -1 ] 28 28 28 28 2796 28 2796 Weight [kg] 3 3 3 3 3 3 4 Max. air temperature [ C] -/ -/ -/ -/ -/ -/ -/ Impeler Protection class: motor IP44 IP44 IP44 IP44 IP44 IP44 IP44 Ecodesign data 1 MD 3. 1 LD 3. 125 MD 3. 125 LD 3. 15 LD 3. 1 MD 3. 1 LD 3. terminal box IP55 IP55 IP55 IP55 IP55 IP55 IP55 Clasification** RVU RVU RVU RVU RVU RVU RVU Energy efficiency class [local demand control] C C C C B C B Sound power level [] 46 58 42 54 59 54 57 Reference flow rate at 5 Pa [m 3 /h] 121 182 1 431 224 483 SPI [W/(m 3 /h)],22,,22,19,14,17,12 Comply with ERP 18 +* +* +* +* +* +* +* * unit with local demand control complies with ErP 18 requirements. ** RVU - residential ventilation unit. 24 The fan characteristic curves were determined in accordance with EN ISO 581. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. The company reserves the right to make changes of technical data without prior notice

VKAP MD 3. 18 1 1 8V 1V 1V 1 17V 1 23V 8 MD 3. Lwa total, Lwa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 7 46 53 62 66 63 64 54 Outlet 71 45 54 61 68 64 65 53 Surrounding 55 22 24 41 49 53 43 Measured at 653 m 3 /h, 125 Pa VKAP LD 3. 18 1 1 1 1 8 8V 1V 1V 17V 23V LD 3. Lwa total, Lwa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 73 53 66 69 66 65 63 Outlet 74 54 62 65 7 67 67 63 Surrounding 58 25 35 46 53 55 47 45 Measured at 846 m 3 /h, 123 Pa VKAP 25 MD 3. 1 8V 1V 1V 1 17V 23V 8 25 MD 3. Lwa total, Lwa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 71 41 52 61 66 66 64 56 Outlet 72 43 53 68 67 65 57 Surrounding 52 24 3 38 48 47 45 Measured at 634 m 3 /h, 125 Pa The fan characteristic curves were determined in accordance with EN ISO 581. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. The company reserves the right to make changes of technical data without prior notice 25

VKAP 25 LD 3. VKAP 315 MD 3. 18 1 1 1 1 8 35 3 25 15 25 LD 3. Lwa total, Lwa, 8V 1V 1V 17V 23V 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 74 54 62 67 69 67 67 65 Outlet 75 55 63 66 7 68 67 67 Surrounding 55 33 38 47 5 48 47 46 Measured at 81 m 3 /h, 123 Pa 8V 1V 1V 17V 23V 1 315 MD 3. Lwa total, Lwa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz 5 Inlet 78 52 63 71 75 68 65 63 Outlet 79 53 64 71 76 69 68 66 Surrounding 57 35 43 51 53 48 46 43 Measured at 1195 m 3 /h, 152 Pa VKAP 315 LD 3. 35 3 25 8V 1V 1V 17V 23V 15 1 5 315 LD 3. Lwa total, Lwa, 125 Hz 25 Hz 5 Hz 1 khz 2 khz 4 khz 8 khz Inlet 73 5 59 67 68 66 65 64 Outlet 74 51 66 69 67 66 65 Surrounding 53 33 38 45 48 47 45 43 Measured at 18 m 3 /h, 149 Pa 26 The fan characteristic curves were determined in accordance with EN ISO 581. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. The company reserves the right to make changes of technical data without prior notice

Electrical data Phase/Votage/Frequency [V/Hz] ~1, 23/5 ~1, 23/5 ~1, 23/5 ~1, 23/5 ~1, 23/5 ~1, 23/5 Max. power consumption [kw],13,14,13,14,219,278 Max. current [A],5,6,5,6,9 1,2 Capacitor [µf] 2 4 2 4 5 5 Wiring diagram No. 1 No. 1 No. 1 No. 1 No. 1 No. 1 Fan speed controller Technical data Max. airflow [m 3 /h] 816 17 817 967 1372 1448 Fan impeler speed [min -1 ] 2796 2659 2796 2659 274 2762 Weight [kg] 4 4,7 4 4,7 5,6 6 Max. air temperature [ C] -/ -/5 -/ -/5 -/5 -/5 Impeler Protection class: motor IP44 IP44 IP44 IP44 IP44 IP44 Ecodesign data terminal box IP55 IP55 IP55 IP55 IP55 IP55 Clasification** NRVU NRVU NRVU NRVU NRVU NRVU Sound power level [] 53 56 5 54 56 53 Nominal flow rate [m 3 /s],12,15,12,16,22,29 Nominal external pressure [Pa] 247 312 247 288 4 318 Static efficiency of fans used in accordance with Regulation No 327/11 MD 3. LD 3. 25 MD 3. 25 LD 3. 315 MD 3. 315 LD 3. [%] 28,3 34,7 28,2 34,4 39,5 37,7 Comply with ERP 18 + + + + + + ** NRVU - non-residential ventilation unit. Wiring diagram No. 1 YE/GN - yellow/green BK - black RD - red BN - brown BU - blue The company reserves the right to make changes of technical data without prior notice 27