CRNE5-10 A-FGJ-G-E-HQQE 3x400 50HZ

Similar documents
CRE5-16 A-A-A-E-HQQE 3x400 50HZ

CRNE15-03 A-FGJ-G-V-HQQV 3x HZ

CRE15-01 A-F-A-E-HQQE 1x HZ

CRE45-1 A-F-A-E-HQQE 3x HZ

CRE20-03 A-A-A-E-HQQE 3x HZ

Grundfos pump

CRE10-02 A-A-A-E-HQQE 1x HZ

CRN20-02 A-FGJ-G-E-HQQE 3x400D 50 HZ

CRE A-F-A-E-HQQE 3x HZ

CRI3-6 A-FGJ-I-E-HQQE 3x230/400 50HZ

CRE32-3 AN-F-A-E-HQQE 3x HZ

CR3-19 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR5-6 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR3-6 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR1-3 A-FGJ-A-E-HQQE 1x220/240 50HZ

CRN5-7 A-P-G-E-HQQE 3x230/400 50HZ

CR5-26 A-FGJ-A-E-HQQE 3x400D 50HZ

CRN3-25 A-P-G-E-HQQE 3x400D 50HZ

CR3-2 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR15-02 A-F-A-E-HQQE 3x400D 50 HZ

CR3-10 A-A-A-E-HQQE 3x230/400 50HZ

CR10-04 A-A-A-E-HQQE 15kW 3x400Y 50Hz

CR10-02 A-A-A-E-HQQE 3x230/ HZ

CRI1-6 A-P-I-E-HQQE 3x230/400 50HZ

CR3-13 A-A-A-E-HQQE 1x220/240 50HZ

CR5-16 A-A-A-E-HQQE 3x400D 50HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR45-5 A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR1S-6 A-A-A-E-HQQE 1x220/240 50HZ

CR1-9 A-A-A-E-HQQE 1x220/240 50HZ

CR10-01 A-A-A-E-HQQE 1x220/ HZ

CRN3-3 A-FGJ-G-V-HQQV 3x230/400 50HZ

CR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz

CR10-10 A-A-A-E-HQQE 3x400D 50 HZ

CR120-2 A-F-A-E-HQQE 3x400/ HZ

CR1-6 A-A-A-E-HQQE 3x230/400 50HZ

CR1-3 A-A-A-E-HQQE 3x230/400 50HZ

CRN15-17 A-FGJ-G-V-HQQV 3x400/ HZ

CRN1-27 A-P-G-V-HQQV 3x230/400 50HZ

CR45-10 A-F-A-E-HQQE 3x400/ HZ

CRN3-11 A-P-G-V-HQQV 11kW 3x400Y 50Hz

CRN15-01 A-P-G-V-HQQV 3x230/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CRE A-F-A-E-HQQE 3x HZ

CRN15-03 A-P-G-V-HQQV 3x400D 50 HZ

CRN3-6 A-P-G-V-HQQV 3x230/400 50HZ

CRN45-5 A-F-G-V-HQQV 3x400/ HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CRE20-08 A-F-A-E-HQQE 3x HZ

NB80-160/161 A-F2-A-BQQE

CR A-F-A-V-HQQV 3x400/ HZ

CRN45-10 A-F-G-V-HQQV 3x400/ HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CRN A-F-G-V-HQQV 30kW 3x400D 50Hz

CR3-17 A-FGJ-A-E-HQQE 1x220/240 50HZ

CRI5-4 A-FGJ-I-E-HQQE 3x230/400 50HZ

CRI10-04 A-FGJ-I-E-HQQE 3x230/ HZ

CRI15-04 A-FGJ-I-E-HQQE 3x400D 50 HZ

CR5-7 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR1-4 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz

CR5-18 A-FGJ-A-E-HQQE 3x400D 50HZ

CR A-F-A-V-HBQV 3x400/ HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

NBE50-250/205 A-F2-A-BAQE

CR45-3 A-F-A-E-HQQE 3x400/ HZ

CRN3-7 A-P-G-E-HQQE 3x230/400 50HZ

CRI3-25 A-P-I-E-HQQE 3x400D 50HZ

CR3-7 A-A-A-E-HQQE 1x220/240 50HZ

CR15-01 A-F-A-E-HQQE 3x230/ HZ

CRN5-5 A-FGJ-G-V-HQQV 3x230/400 50HZ

CR10-08 A-A-A-E-HQQE 3x400D 50 HZ

CR5-9 A-A-A-E-HQQE 3x230/400 50HZ

CRN10-02 A-P-G-E-HQQE 3x230/ HZ

CRIE10-03 A-FGJ-I-E-HQQE 3x HZ

CR15-14 A-F-A-E-HQQE 3x400/ HZ

CR1-4 A-A-A-E-HQQE 3x230/400 50HZ

CRN10-09 A-FGJ-G-V-HQQV 3x400D 50 HZ

CRN A-F-G-V-HQQV 3x400/ HZ

NKE80-160/175A2F2AE-SBQQE

NB /193 A-F2-A-BAQE

CRN5-22 A-P-G-V-HQQV 3x400D 50HZ

TPED /4-A-F-A-BQQE 3X400 50HZ

CRN120-3 A-F-G-V-HQQV 3x400/ HZ

CRNE15-12 A-FGJ-G-V-HQQV 3x HZ

NK /310A2F1AE-SBAQE

TP /4-A-F-A-BQQE 400Y 50HZ

Hydro MPC-E 2CRIE L GNL

CRNE AN-F-G-E-HQQE 3x HZ

TPE /2-S-A-F-A-BAQE 3X400 50HZ

TP /2-A-F-A-BQQE 400D 50HZ

CRN1S-9 A-P-G-V-HQQV 3x230/400 50HZ

TPE /4-A-F-A-BAQE 3X400 50HZ

NBE40-125/139 AS-F2-A-BAQE

TPED /4-S-A-F-A-BAQE 3X400 50HZ

NB /263 AS-F2-A-BAQE

TP /2-A-F-A-BAQE 400D 50HZ

TPE N-A-F-A-GQQE

Transcription:

GRUNDFOS DATA BOOKLET CRNE5-1 A-FGJ-G-E-HQQE 3x4 5HZ Grundfos Pump 96518519 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crne5/96518519/crne-5-1-a-fgj-g-e-hqqe.html info@lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89 BE > THINK > INNOVATE

Position Qty. Description 1 CRNE 5-1 A-FGJ-G-E-HQQE Product No.: 96518519 Note! Product picture may differ from actual product Vertical, multistage centrifugal pump with suction and discharge ports on same the level (in-line) enabling installation in a horizontal one-pipe system. Pump materials in contact with the liquid are in high-grade stainless steel. A cartridge shaft seal ensures high reliability, safe handling and easy service and access. Power transmission is via a split coupling. Pipework connection is via combined DIN-ANSI-JIS flanges. The pump is fitted with a 3-phase, fan-cooled asynchronous motor. The motor includes a frequency converter and PI controller in the motor terminal box. This enables continuously variable control of the motor speed, which again enables adaptation of the performance to a given requirement. Further product details An external sensor can be connected if controlled pump operation based on for example flow, differential pressure or temperature is required. A control panel on the motor terminal box enables setting of required setpoint as well as setting of pump to "Min." or "Max." operation or to "Stop". The control panel has indicator lights for "Operation" and "Fault". Communication with the pump is possible by means of the Grundfos GO Remote or the R1 remote control (accessories). The remote controls enable further settings as well as reading out of a number of parameters such as "Actual value", "Speed", "Power input" and total "Power consumption". The product carries the Grundfos Blueflux label. It represents the best from Grundfos within energy-efficient motors and frequency converters. Grundfos Blueflux solutions either meet or exceed legislative requirements such as the EuP IE3 grade. Steel, cast iron and aluminium components have an epoxy-based coating made in a cathodic electro-deposition (CED) process. CED is a high-quality dip-painting process where an electrical field around the products ensures deposition of paint particles as a thin, well-controlled layer on the surface. An integral part of the process is a pretreatment. The entire process consists of these elements: 1) Alkaline-based cleaning. 2) Zinc phosphating. 3) Cathodic electro-deposition. 4) Curing to a dry film thickness 18-22 my m. The colour code for the finished product is NCS 9/RAL 95. Pump 1/9

Position Qty. Description A standard split coupling connects the pump and motor shaft. It is enclosed in the pump head/motor stool by means of two coupling guards. The pump head and flange for motor mounting is made in one piece (cast iron). The pump head cover is a separate component (stainless steel). The pump head has a combined 1/2" priming plug and air vent screw. The pump is fitted with a balanced O-ring seal unit with rigid torque transmission system. This seal type is assembled in a cartridge unit which makes replacement safe and easy. Due to the balancing, this seal type is suitable for high-pressure applications. The cartridge construction also protects the pump shaft from possible wear from a dynamic O-ring between pump shaft and shaft seal. Primary seal: - Rotating seal ring material: Silicon carbide (SiC) - Stationary seat material: Silicon carbide (SiC) This material pairing is used where higher corrosion resistance is required. The high hardness of this material pairing offers good resistance against abrasive particles. Secondary seal material: EPDM (ethylene-propylene rubber) EPDM has excellent resistance to hot water. EPDM is not suitable for mineral oils. The shaft seal is screwed into the pump head. The chambers and impellers are made of stainless steel sheet. The chambers are provided with a PTFE neck ring offering improved sealing and high efficiency. The impellers have smooth surface, and the shape of the blades ensure a high efficiency. The pump has a stainless steel base mounted on a separate base plate. The base and base plate are kept in position by the tension of the staybolts which hold the pump together. The discharge side of the base has a combined drain plug and bypass valve. The pump is secured to the foundation by four bolts through the base plate. The flanges are fastened to the base by means of locking rings. 2/9

Motor The motor is a totally enclosed, fan-cooled motor with principal dimensions to IEC and DIN standards. The motor is flange-mounted with tapped-hole flange (FT). Motor mounting designation in accordance with IEC 634-7: IM B 14 (Code I) / IM 361 (Code II). Electrical tolerances comply with IEC 634. The motor requires no external motor protection. The motor control unit incorporates protection against slow- and quick-rising temperatures, e.g. constant overload and stalled conditions. The terminal box holds terminals for these connections: - pump start/stop input (potential-free contact) - remote setpoint setting via analog signal, -1 V, (4)-2 ma - 1 V voltage supply for setpoint potentiometer, Imax = 5 ma - one analog sensor input, -1 V, (4)-2 ma - 24 V voltage supply for sensor, Imax = 4 ma - one analog output - three digital inputs - one potential-free fault signal relay with changeover contact, reporting "Fault", "Operation" or "Ready" - RS-485 GENIbus connection. Technical data Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Approvals on nameplate: Materials: Pump housing: Impeller: Water 253.. 393 K 293 K 998.2 kg/m³ 2896 rpm 5.7 m³/h 49.8 m HQQE CE,TR Stainless steel DIN W.-Nr. 1.448 AISI 316 ASTM A 351 CF 8M Stainless steel DIN W.-Nr. 1.441 AISI 316 Installation: 3/9

Position Qty. Description Maximum ambient temperature: 313 K Max pressure at stated temp: 25 bar / 12 C 25 bar / -2 C Flange standard: DIN Pipe connection: DN 25 / DN 32 Pressure stage: PN 25 Flange size for motor: FT115 Electrical data: Motor type: 9SB Number of poles: 2 Rated power - P2: 1.5 kw Power (P2) required by pump: 1.5 kw Mains frequency: 5 Hz Rated voltage: 3 x 38-48 V Rated current: 3,3-2,7 A Cos phi - power factor:,91-,87 Rated speed: 36-351 rpm Efficiency: IE3 84,2% Enclosure class (IEC 34-5): IP55 Insulation class (IEC 85): F Others: Label: Grundfos Blueflux Minimum efficiency index, MEI :.57 Net weight: 43.5 kg Gross weight: 49.1 kg Shipping volume:.8 m3 4/9

96518519 CRNE 5-1 5 Hz H [m] 75 CRNE 5-1, 3*4 V, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ eta [%] 7 1 % 65 6 55 5 1 45 9 4 8 35 7 3 6 25 5 2 4 15 3 1 2 5 25 % 1.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. 5.5 6. 6.5 7. 7.5 8. 8.5 P [kw] Q [m³/h] NPSH [m] 2. 8 P1 1.5 P2 6 1. 4.5 2. 5/9

Description Value Product name: CRNE 5-1 A-FGJ-G-E-HQQE Product No: 96518519 EAN number: 57396784755 Technical: Speed for pump data: 2896 rpm Rated flow: 5.7 m³/h Rated head: 49.8 m Impellers: 1 Shaft seal: HQQE Approvals on nameplate: CE,TR Stages: 1 Pump version: A Model: A Materials: Pump housing: Impeller: Material code: Code for rubber: Stainless steel DIN W.-Nr. 1.448 AISI 316 ASTM A 351 CF 8M Stainless steel DIN W.-Nr. 1.441 AISI 316 G E H [m] 7 65 6 55 5 45 4 35 3 25 2 15 1 5 P [kw] 1.5 1..5. 1 % 25 % 1 2 3 4 5 6 7 14 CRNE 5-1, 3*4 V, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ 15 89 32 Q [m³/h] P1 P2 eta [%] 1 9 8 7 6 5 4 3 2 1 NPSH [m] 6 4 2 Installation: Maximum ambient temperature: 313 K Max pressure at stated temp: 25 bar / 12 C 25 bar / -2 C Flange standard: DIN Connect code: FGJ Pipe connection: DN 25 / DN 32 Pressure stage: PN 25 Flange size for motor: FT115 167 178 281 14 G 1/2 19 x 27 52 4 x 13 75 34 1 15 85 18 21 25 Liquid: Pumped liquid: Water Liquid temperature range: 253.. 393 K Liquid temp: 293 K Density: 998.2 kg/m³ Electrical data: Motor type: 9SB Number of poles: 2 Rated power - P2: 1.5 kw Power (P2) required by pump: 1.5 kw Mains frequency: 5 Hz Rated voltage: 3 x 38-48 V Rated current: 3,3-2,7 A Cos phi - power factor:,91-,87 Rated speed: 36-351 rpm Efficiency: IE3 84,2% Enclosure class (IEC 34-5): IP55 Insulation class (IEC 85): F Motor protec: NONE Motor No: 8575586 Group 3 Group 2 NC C NO L1 L2 L3 1: Digital input 9: GND (frame) 8: +24 V 7: Sensor input B: RS-485B Y: Screen A: RS-485A -1 V /4-2 ma 4-2 ma Group 1 1/ B Y A 1 9 8 7 STOP 6: GND (frame) 5: +1 V 4: Setpoint input 3: GND (frame) 2: Start/stop RUN /4-2 ma -1 V 1K 6 5 4 3 2 Others: Label: Grundfos Blueflux Minimum efficiency index, MEI :.57 Net weight: 43.5 kg Gross weight: 49.1 kg Shipping volume:.8 m3 6/9

Description Value Config. file no: 9611584 7/9

96518519 CRNE 5-1 5 Hz 167 178 52 G 1/2 14 19 x 27 4 x 13 75 89 15 14 281 1 15 25 34 85 18 21 32 Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details. 8/9

96518519 CRNE 5-1 5 Hz NC C NO Group 2 L1 L2 L3 Group 3-1 V /4-2 ma 4-2 ma 1/ 1 9 8 7 B Y A 1: Digital input 9: GND (frame) 8: +24 V 7: Sensor input B: RS-485B Y: Screen A: RS-485A Group 1 STOP /4-2 ma -1 V RUN 1K 6 5 4 3 2 6: GND (frame) 5: +1 V 4: Setpoint input 3: GND (frame) 2: Start/stop Note! All units are in [mm] unless others are stated. 9/9

Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date. All information is copyright Grundfos. info@lenntech.com www.lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89