PENTEK XE-6. OWNER S MANUAL 6 Submersible Motors 293 WRIGHT STREET, DELAVAN, WI PH: PENTEK

Similar documents
OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

SAE Engine Mount. Selection For Pumping Application. Matching Pump End To Engine. Type B Centrifugal Pumps Close coupled pump ends.

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

SHEF30 Submersible Sump/ Effluent Pump

6TSP Series Radial Flow

MYERS INSTALLATION AND SERVICE MANUAL CENTRI-THRIFT CENTRIFUGAL PUMPS. Models 125M/B, 150M/B and 200M/B

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

Model B1-1/2XQBS-11. Model B1-1/2XQBS-18. Model B1-1/2XQBS-26

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

ESE Series Cast Iron Sewage Pumps

Self-Priming Centrifugal Pumps

Installation, Operation & Parts Manual BV40 Submersible Sewage Ejector Pump

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

SPECIFICATIONS Power supply required...see Motor and Cord Specifications chart below Motor duty...intermittent Discharge Adapter...

SUBMERSIBLE SWIMMING POOL DRAINER

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

INSTALLATION AND SERVICE MANUAL MSKV50 Submersible Sewage Ejector Pump

OWNER S MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST 60 CYCLE SELF-PRIMING CENTRIFUGAL PUMPS D SERIES MODELS

OWNER S MANUAL CP, CB SERIES CENTRIFUGAL PUMP

SP40 Submersible Sewage Ejector Pump

Installation & Operating Manual

SUBMERSIBLE SUMP PUMPS

SUBMERSIBLE SUMP PUMPS

Installation and Service Manual OSP50/OSP50AB Submersible Effluent Pumps

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

AUTOMATIC SUBMERSIBLE UTILITY PUMP

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

ON-SITE WASTEWATER PRODUCTS

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

Installation and Service Manual SK50 Submersible Sewage Ejector Pump

SS/SSH Submersible Pump. Owner s Manual

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS

Submersible Sewage Ejector Pump

FP0S2300X FP0S3000X. Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien,

TABLE OF CONTENTS. Pump Selection General Safety Electrical Installation Troubleshooting Repair Parts...

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

For technical questions and replacement parts, please call

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

HVR200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

Table of Contents 1 1. GENERAL SAFETY GUIDELINES. 2. NOMENCLATURE 2.1 Motors 2.2 Variable/High Speed Drives 2.3 Submersible Motor Controls

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

GARDEN HOSE UTILITY PUMP

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

4" Submersible Motors

4" Submersible Motors XE-SERIES

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST

Boston Gear Ratiotrol

Pump Installation and Service Manual HRS Hydromatic Retractable System

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

TPAK Series COOLANT PUMP

1. Contents 1. CONTENTS INTRODUCTION SAFETY WARNINGS POWER TILT STANDARD OPERATING INSTRUCTIONS... 5.

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

MODEL MRG20 GRINDER PUMP INSTALLATION AND SERVICE MANUAL. 2 HP Grinder Pump for Residential Applications.

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

HV200 SERIES GRINDER PUMPS INSTALLATION AND SERVICE MANUAL

Swing Arm Magnifying Lamp

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

Motors " GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2

Self-Priming Horizontal Three and Four Stage Pumps

Owner's/Installation Manual

Submersible Solids Handling Pumps

Pump Installation and Service Manual SKV50 Submersible Sewage Ejector Pump

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

MODELS 4V, 4R, 4VH, 6VH, 4VC and 6VC

SKHS Series Submersible High Head Sewage Ejector Available Horsepower: 1/2, 1, 1-1/2, 2

Motor Application and Installation Data

HYDROMATIC HE8/HE12/HE20/HE25/ HE30/HE35/HE50 HIGH HEAD FILTERED EFFLUENT

Potable Water Submersible Turbine Pumps

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

PRE-PLUMBED SEWAGE SYSTEM

CTFRP Series Power Supplies

TECHNICAL BROCHURE BCP3PH R9. Three Phase 4" Motors, ½-10 HP 60 HERTZ, 3450 RPM

MODEL SPC-PANEL. Pump Controls for 2 HP Grinder Pumps

OWNER S MANUAL Submersible Sewage Ejector Pumps

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

Owner s Manual GLASSLINED PUMP TANK

Call DS3 Series. Installation/Operation/Parts For further operating, installation, or maintenance assistance:

High Performance Output Sine Wave Filter Installation, Operation, and Maintenance Manual

Installation, Operation and Maintenance Manual

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

The Da-Lite Difference.

SPC-PANEL Simplex, Single Phase Pump Control Panel

Extension Hopper Installation & Operator s Instruction Manual for Model 55, 75, 90, & HMC FLEX-AUGER Feed Delivery Systems

Audi R8. Ride-on Car 5F62630 OWNER S MANUAL. Keep instructions for future reference

OWNERS GUIDE TO INSTALLATION AND OPERATION OF 1/2-5 HP, 5, 7, 10, 15, 19 & 27 GPM 4 SUBMERSIBLE PUMPS

Instruction Book for. ContouR ElECtRol

LEV/Wn Building A Connected World

Redi-Flo4. Stainless Steel Submersible Pumps for Environmental Applications GRUNDFOS INSTRUCTIONS. US Installation and operating instructions

3 TON JACK STANDS. Operator s Instruction Manual. Rated Capacity 6,000-lb MODEL# T43002T

TECHNICAL BROCHURE BC3WIRE-G2 R4

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

Owner s Manual & Safety Instructions

Transcription:

OWNER S MANUAL 6 Submersible Motors PENTEK XE-6 232852 DRINKING WATER SYSTEM COMPONENT ANSI/NSF 61-G 3RZE 293 WRIGHT STREET, DELAVAN, WI 53115 WWW.PUMPS.COM PH: 1-866-9 PENTEK 2015 Pentair Ltd. All Rights Reserved. PN989 (Rev. 10/01/15)

Safety 2 Important Safety Instructions SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation, operation, and maintenance. This is the safety alert symbol. When you see this symbol in this manual, look for one of the following signal words and be alert to the potential for personal injury! indicates a hazard which, if not avoided, will result in death or serious injury. indicates a hazard which, if not avoided, could result in death or serious injury. indicates a hazard which, if not avoided, could result in minor or moderate injury. NOTICE addresses practices not related to personal injury. Carefully read and follow all safety instructions in this manual. Keep safety labels in good condition. Replace missing or damaged safety labels. California Proposition 65 Warning This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Handling and Installation Instruction LIFTING 1. Heavy Object. Lifting equipment must be capable of lifting motor and attached equipment. Check over all tools, especially the hoisting gear, for wear or damage before hoisting the unit. 2. If the total length of the pump and motor unit (without any riser pipe attached) exceeds 10ft (3m), support the unit with a girder while hoisting (see Figure 1). Do not remove the supporting girder until the unit is standing vertically in the hoist. Check for damage. ELECTRICAL (See Pages 5 & 6, for Product Specifications) 1. Risk of electrical shock if the cable is damaged. Inspect the motor cable for any nicks or cuts. Do not use the motor cable to pull, lift, or handle the motor. Protect the motor cable during storage, handling, moving, and installation of the motor. 2. Inspect the motor to determine that it is the correct horsepower, voltage, and size for the job and that there is no shipping damage. Verify that the motor nameplate voltage matches the available power supply voltage. The nameplate rated voltage must not vary more than ± 10% from the power supply voltage. 3. On all new installations and after the motor has sat idle for a long period of time, check the motor s internal electrical resistance with a megohmmeter with lead wires connected. Prior to installation, the motor should have an insulation value of at least 500 megohms. After installation, the motor and power cable should have a minimum insulation value of 1 megohm. If the minimum values are below the listed values, contact the factory before starting the motor. 4. Fuses or circuit breakers and overload protection are required. Fuses or circuit breakers and overloads must be sized in accordance with National Electrical Code (NEC) or Canadian Electrical Code (CEC) requirements, as applicable, and with all applicable local codes and ordinances. See page 6 for more information on fuse and breaker sizing. 5. Wire and ground the motor in accordance with National Electrical Code (NEC) or Canadian Electrical Code (CEC) requirements, as applicable, and with all applicable local codes and ordinances. Less Than 10 Ft (3 M) 10 Ft (3M) or More 10 Ft (3M) or More Support the pump and motor! Lack of support will destroy the motor! Figure 1: When the pump and motor together (without any riser pipe) are 10ft (3m) long or more, support the assembly before lifting to avoid bending it in the middle. Never try to lift the motor or pump by the motor cables.

Safety 3 MOTOR STORAGE AND INSTALLATION 1. The motor is filled at the factory with propylene glycol mixture which will protect it in temperatures down to 2.4ºF (-16ºC). Do not install, transport or store the motor below these temperatures if the motor is filled. 2. NOTICE To avoid damaging the motor thrust bearing, do not hammer on the shaft, coupling, or slinger. Check the motor rotation by hand to make sure that it turns freely. 3. To avoid damage to the motor diaphragm, make sure that the bottom of the motor does not touch the dirt or mud at the bottom of the well. Install the motor at least 10 above the well bottom. 4. To install the motor horizontally, lay it down with the lead wires at 12 o clock when you are facing the motor shaft. To prevent any load on the shaft and bearings and to avoid any damaging vibrations to the motor, mount the motor solidly on the pump end and make sure that the pump and motor are accurately aligned. 5. Install the motor so that during operation water flows past all parts of it at a rate of at least 0.5 fps (0.15 mps). If the well will not provide this flow, install a sleeve on the motor to channel water past it (see Figure 2). Do not try to operate the motor in mud or sand. To do so will damage the motor and void the warranty. 6. Electrical connections: Connect the three leads to the three hot motor leads (red/yellow/black) in the incoming cable. Connect the ground wire (green) in accordance with NEC or CEC requirements (as applicable) and in accordance with all applicable local codes and ordinances. For 3-Phase motor installations, apply power momentarily to check rotation. If the motor runs backwards, interchange any two power leads to reverse direction of rotation. Well Water Pump Flow Inducer Sleeve Motor 10 (3M) or more NOT TO SCALE Figure 2: If flow past motor is less than.5 fps (0.15 mps), install a flow inducer sleeve as shown. Flow must be at least.5 7008 0915 fps (0.15 mps) for adequate motor cooling. The flow inducer sleeve should not touch the side of the motor.

Safety 4 APPLICATION LIMITS Maximum Immersion Depth: 1148 ft. (350 m) Maximum Water Temperature: 95 F (35 C) ph content of the water: 6 8 Minimum Cooling Flow Rate: 0.5 feet per second (fps) (0.15meters per second (mps)). Required line voltage at the motor under operating conditions (±10%). NOTICE When calculating voltage at the motor, be sure to allow for voltage drop in the cable. The sum of the absolute values of the voltage and frequency must not vary from the sum of the nominal values by more than ±10%. Operating 3-phase motors with current unbalanced on the three legs of the circuit can overheat and damage the motor and will void the warranty. Current imbalance must not exceed 5% maximum. Maximum Sand Content: 50ppm (max. size 0.1 0.25mm) Maximum Chlorine Ion Content: 4ppm Pentek single phase control boxes for Pentek XE-6 single phase motors 60Hz 2 POLE CONTROL BOX DIMENSIONS HEIGHT WIDTH DEPTH PHASE MODEL # HP KW VOLTS IN MM IN MM IN MM LBS KG PTKX-5SCB 5 3.70 30 13.6 PTKX-7SCB 7.5 5.60 32 14.5 1 230 14.0 356 12.0 304.8 6.0 152.4 PTKX-10SCB 10 7.50 33.2 15.1 PTKX-15SCB 15 11.20 The control box and motor are designed to work together. Be certain that the control box and motor horsepower and voltage match. Warranty coverage is only applicable when a Pentek single phase control box (models listed in chart above) is used with a Pentek XE single phase motor. TROUBLESHOOTING Problem Possible Causes Solution Motor does not start, but does not blow fuses or trip circuit breaker Motor starts, but fuses blow or circuit breakers trip Motor starts and runs, then blows fuse or trips circuit breaker Defective fuses or circuit breakers Loose or corroded terminals Damaged or defective connections No incoming power Wrong voltage Incorrect fuses or relay Incorrect connections Locked rotor or pump Insufficient insulation on motor cables Incoming voltage more than 10% high or low Sand in well Replace fuses or circuit breakers. Clean and tighten connections and motor lead terminals. Repair or replace connections. Contact power company. Make sure that nameplate rated voltage matches nominal power supply, and that actual supply voltage is within ±10% of nameplate voltage. Install correct fuses or relay. Re-connect motor wires correctly. Make sure that motor is at least 10ft above bottom of well, check well for sand. Install new motor cables; recheck resistance with Megohmeter. Confirm high or low voltage in motor cable, consult power company. Pull the pump and clean the well. Motor does not start, but fuse blows or circuit breaker trips locked rotor or pump Check for sand in well. Make sure that motor is at least 10ft above the bottom of the well. Pull pump and check for mechanical obstruction in the pump and for free rotation of the motor.

Product Specifications 5 Nominal Diameter - 6 / 152.4mm Effective Diameter - 5.43 / 138mm 60Hz 2 POLE 3450 RPM CLASS F INSULATION TEMPERATURE RATING 95 F/35 C IP 68 PROTECTION RATING PHASE MODEL # HP KW VOLTS P60A0050A2 5 3.70 FULL LOAD SERVICE FACTOR LOAD (1.15) LOCKED ROTOR AMPS WATTS EFF % PF % AMPS WATTS EFF % PF % AMPS 22.8 4975 74.5 97.0 26.0 5625 75.5 97.0 104 THRUST LOAD (LBS) KVA CODE E P60A0075A2 7.5 5.60 35.2 7300 77.0 92.0 40.0 8300 77.5 92.5 162 F 1 230 P60A0100A2 10 7.50 45.7 9700 76.5 94.0 52.4 11175 76.5 94.0 202 E P60A0150A2 15 11.20 62.4 13725 81.5 98.0 72.5 15825 81.5 98.0 296 E P60A0050A8 5 3.7 16.1 4830 77.5 86.5 18.0 5490 78.5 88.0 96 H P60A0075A8 7.5 5.5 23.3 7000 80.0 87.5 26.8 8070 80.0 88.5 140 H P60A0100A8 10 7.5 31.5 9090 82.5 86.5 35.0 10400 82.5 88.0 187 H P60A0150A8 15 11 200-208 44.9 13440 83.5 87.0 50.8 15460 83.5 88.5 268 H P60A0200A8 20 15 59.0 17850 83.0 87.5 67.1 20630 83.0 89.0 354 H P60A0250A8 25 19 76.8 22110 84.0 85.5 86.5 25520 84.0 87.5 445 H P60A0300A8 30 22 91.7 26420 84.5 86.0 103.3 30450 84.5 87.5 530 H P60A0050A3 5 3.7 14.4 4830 77.5 86.5 16.1 5490 78.5 88.0 87 3600 H P60A0075A3 7.5 5.5 21.5 7000 80.0 87.5 24.1 8070 80.0 88.5 127 H P60A0100A3 10 7.5 28 9090 82.5 86.5 31.5 10400 82.5 88.0 164 H P60A0150A3 15 11 230 40.9 13440 83.5 87.0 46.3 15460 83.5 88.5 237 H P60A0200A3 20 15 53.2 17850 83.0 87.5 60.8 20630 83.0 89.0 312 G P60A0250A3 25 19 66.7 22110 84.0 85.5 76.0 25520 84.0 87.5 387 G P60A0300A3 30 22 79.3 26420 84.5 86.0 90.2 30450 84.5 87.5 458 G P60A0050A4 5 3.7 7.0 4830 77.5 86.5 8.0 5490 78.5 88.0 44 H 3 P60A0075A4 7.5 5.5 10.0 7000 80.0 87.5 11.3 8070 80.0 88.5 62 H P60A0100A4 10 7.5 13.1 9090 82.5 86.5 14.8 10400 82.5 88.0 82 H P60A0150A4 15 11 20.4 13440 83.5 87.0 23.0 15460 83.5 88.5 117 G P60A0200A4 20 15 460 25.8 17850 83.0 87.5 29.4 20630 83.0 89.0 151 G P60A0250A4 25 19 32.8 22110 84.0 85.5 36.8 25520 84.0 87.5 187 G P60A0300A4 30 22 39.3 26420 84.5 86.0 44.6 30450 84.5 87.5 226 G P60A0400A4 40 30 51.3 35030 85.0 87.5 58.6 40500 85.0 89.0 302 G 6750 P60A0500A4 50 37 65.8 44350 84.0 87.0 75.1 51200 84.0 88.0 385 G P60A0050A5 5 3.7 5.8 4830 77.5 86.5 6.5 5490 78.5 88.0 35 H P60A0075A5 7.5 5.5 8.2 7000 80.0 87.5 9.3 8070 80.0 88.5 51 H P60A0100A5 10 7.5 10.5 9090 82.5 86.5 11.8 10400 82.5 88.0 61 G P60A0150A5 15 11 15 13440 83.5 87.0 17.1 15460 83.5 88.5 88 3600 G 575 P60A0200A5 20 15 20.9 17850 83.0 87.5 23.7 20630 83.0 89.0 122 G P60A0250A5 25 19 26.2 22110 84.0 85.5 29.7 25520 84.0 87.5 153 G P60A0300A5 30 22 31 26420 84.5 86.0 35.0 30450 84.5 87.5 179 G P60A0400A5 40 30 41.5 35030 85.0 87.5 47.3 40500 85.0 89.0 247 6750 G

Product Specifications (cont.) 6 Nominal Diameter - 6 / 152.4mm Effective Diameter - 5.43 / 138mm 60Hz 2 POLE 3450 RPM Shaft Extension - 2.87 / 73mm PHASE MODEL # HP KW VOLTS P60A0050A2 5 3.70 WINDING RESISTANCE (OHMs) MAIN (BLACK YELLOW) START (RED YELLOW) STANDARD FUSE FUSE SIZING BASED ON NEC GENERATOR SIZING DUAL ELEMENT TIME DELAY FUSE CIRCUIT BREAKER EXTERNALLY REGULATED INTERNALLY REGULATED LENGTH MOTOR (includes shaft ext) WEIGHT MOTOR ONLY kw KVA kw KVA IN MM LBS KG 0.27 0.80 80 50 70 20 25 10 13 25.6 650 104 47.2 P60A0075A2 7.5 5.60 0.40 0.85 125 80 110 30 38 15 19 28.1 714 117 53.1 1 230 P60A0100A2 10 7.50 0.60 1.89 175 90 125 40 50 20 25 30.3 770 132 59.9 P60A0150A2 15 11.20 0.25 0.68 225 150 200 50 63 25 31 32.8 833 144 65.3 LINE TO LINE P60A0050A8 5 3.7 0.96 60 35 50 20 25 10 13 23.0 584 87 39.5 P60A0075A8 7.5 5.5 0.74 90 50 70 30 38 15 19 24.3 617 97 44.0 P60A0100A8 10 7.5 0.42 110 70 100 40 50 20 25 25.6 650 104 47.2 P60A0150A8 15 11 200-208 0.29 175 100 125 50 63 25 31 28.1 714 117 53.1 P60A0200A8 20 15 0.22 225 125 175 75 94 38 47 30.3 770 132 59.9 P60A0250A8 25 19 0.15 300 150 200 80 100 40 50 32.8 833 144 65.3 P60A0300A8 30 22 0.12 350 200 250 100 125 50 63 35.6 904 165 74.8 P60A0050A3 5 3.7 1.23 60 35 45 20 25 10 13 23.0 584 87 39.5 P60A0075A3 7.5 5.5 0.82 80 45 70 30 38 15 19 24.3 617 97 44.0 P60A0100A3 10 7.5 0.56 100 60 90 40 50 20 25 25.6 650 104 47.2 P60A0150A3 15 11 230 0.37 150 90 125 50 63 25 31 28.1 714 117 53.1 P60A0200A3 20 15 0.28 200 110 175 75 94 38 47 30.3 770 132 59.9 P60A0250A3 25 19 0.20 225 150 200 80 100 40 50 32.8 833 144 65.3 P60A0300A3 30 22 0.17 300 175 225 100 125 50 63 35.6 904 165 74.8 P60A0050A4 5 3.7 4.93 30 15 25 20 25 10 13 23.0 584 87 39.5 3 P60A0075A4 7.5 5.5 3.29 40 25 35 30 38 15 19 24.3 617 97 44.0 P60A0100A4 10 7.5 2.15 50 30 40 40 50 20 25 25.6 650 104 47.2 P60A0150A4 15 11 1.30 70 45 60 50 63 25 31 28.1 714 117 53.1 P60A0200A4 20 15 460 1.04 90 50 80 75 94 38 47 30.3 770 132 59.9 P60A0250A4 25 19 0.77 110 70 100 80 100 40 50 32.8 833 144 65.3 P60A0300A4 30 22 0.65 150 80 110 100 125 50 63 35.6 904 165 74.8 P60A0400A4 40 30 0.51 175 100 150 125 156 63 78 39.3 998 187 84.8 P60A0500A4 50 37 0.39 225 150 175 175 219 88 109 54.1 1374 265 120.2 P60A0050A5 5 3.7 6.50 25 15 20 20 25 10 13 23.0 584 87 39.5 P60A0075A5 7.5 5.5 4.04 30 20 25 30 38 15 19 24.3 617 97 44.0 P60A0100A5 10 7.5 3.16 40 25 30 40 50 20 25 25.6 650 104 47.2 P60A0150A5 15 11 2.18 60 30 45 50 63 25 31 28.1 714 117 53.1 575 P60A0200A5 20 15 1.54 80 45 60 75 94 38 47 30.3 770 132 59.9 P60A0250A5 25 19 1.17 90 60 80 80 100 40 50 32.8 833 144 65.3 P60A0300A5 30 22 0.93 110 70 90 100 125 50 63 35.6 904 165 74.8 P60A0400A5 40 30 0.72 150 90 125 125 156 63 78 39.3 998 187 84.8

Cable Selection 7 CABLE SELECTION COPPER CABLE SIZE - From Service Entrance to Motor (Feet) MOTOR AWG MCM 60 C VOLTS /Hz HP KW 14 12 10 8 6 4 3 2 1 0 00 000 0000 250 300 350 400 500 SINGLE PHASE THREE PHASE 460 V 200-208 V 575 V 5 3.7-132 210 332 517 825 1037 1309 1649 2082 2626 3315 4177 4931 7.5 5.5 - - 136 216 336 536 674 851 1072 1353 1707 2155 2715 3205 3848 4498 10 7.5 - - - 165 257 409 514 650 818 1033 1303 1645 2073 2447 2937 3434 3926 4884 15 11 - - - - 185 296 372 469 591 747 942 1189 1498 1768 2123 2482 2837 3530 5 3.7 134 213 339 537 835 1332 1674 2114 2663 3362 4241 7.5 5.5 89 142 226 359 558 890 1118 1412 1779 2246 2833 3577 4506 10 7.5 - - 173 274 427 681 856 1081 1361 1718 2168 2737 3448 4070 4886 15 11 - - - 187 290 463 582 735 926 1169 1475 1862 2346 2769 3324 3886 4443 20 15 - - - - 221 353 443 560 705 890 1123 1418 1786 2109 2532 2959 3383 4209 25 18.5 - - - - 177 282 355 448 564 712 898 1134 1429 1687 2025 2367 2707 3368 30 22 - - - - - 238 299 377 475 600 757 956 1204 1421 1706 1995 2281 2837 5 3.7 538 855 1364 2161 3362 7.5 5.5 381 606 966 1530 2380 3794 4770 10 7.5 291 462 737 1168 1817 2897 3642 4600 15 11 187 298 475 752 1169 1864 2344 2960 3728 4706 20 15-233 371 588 915 1458 1833 2315 2917 3682 4645 25 18.5 - - 297 470 731 1165 1465 1850 2330 2942 3711 4685 30 22 - - - 388 603 961 1209 1526 1923 2427 3062 3866 4870 40 30 - - - 295 459 732 920 1162 1463 1847 2331 2942 3707 4376 50 37 - - - - 358 571 718 906 1142 1441 1818 2296 2892 3415 4099 4792 5 3.7 108 172 274 434 676 1077 1354 1710 2154 2719 3431 4331 7.5 5.5-115 184 292 454 723 909 1149 1447 1826 2304 2909 3665 4327 10 7.5 - - 141 223 347 554 696 879 1108 1398 1764 2227 2806 3313 3977 4649 15 11 - - - 154 239 382 480 606 763 964 1216 1535 1933 2283 2740 3203 3662 4556 20 15 - - - - 181 289 363 459 578 729 920 1162 1464 1728 2074 2425 2772 3449 25 18.5 - - - - - 224 282 356 448 566 714 901 1135 1340 1609 1881 2151 2676 30 22 - - - - - 188 236 298 375 474 598 755 951 1122 1347 1575 1801 2241 5 3.7 827 1316 2099 3324 7.5 5.5 578 920 1467 2323 3615 10 7.5 456 725 1156 1831 2849 4542 15 11 314 500 798 1264 1966 3134 3940 4976 20 15 227 361 576 912 1419 2261 2843 3590 4523 25 18.5-288 459 728 1132 1805 2269 2865 3609 4556 30 22 - - 390 617 961 1531 1925 2431 3063 3866 4877 40 30 - - - 457 711 1133 1424 1799 2266 2861 3609 4556 Lengths only meet the US National Electrical Code ampacity requirements for individual conductors rated 60 C in free air or water, NOT in magnetic enclosures, conduit or direct buried. Refer to NEC Table 310.15(B)(17) for more information. MCM equals circular mills of the wire x 1000

Cable Selection 8 CABLE SELECTION COPPER CABLE SIZE - From Service Entrance to Motor (Feet) MOTOR AWG MCM 75 C VOLTS /Hz HP KW 14 12 10 8 6 4 3 2 1 0 00 000 0000 250 300 350 400 500 SINGLE PHASE THREE PHASE 460 V 200-208 V 575 V 5 3.7-132 210 332 517 825 1037 1309 1649 2082 2626 3315 4177 4931 7.5 5.5 - - 136 216 336 536 674 851 1072 1353 1707 2155 2715 3205 3848 4498 10 7.5 - - - 165 257 409 514 650 818 1033 1303 1645 2073 2447 2937 3434 3926 4884 15 11 - - - - 185 296 372 469 591 747 942 1189 1498 1768 2123 2482 2837 3530 5 3.7 134 213 339 537 835 1332 1674 2114 2663 3362 4241 7.5 5.5 89 142 226 359 558 890 1118 1412 1779 2246 2833 3577 4506 10 7.5-109 173 274 427 681 856 1081 1361 1718 2168 2737 3448 4070 4886 15 11 - - 118 187 290 463 582 735 926 1169 1475 1862 2346 2769 3324 3886 4443 20 15 - - - 142 221 353 443 560 705 890 1123 1418 1786 2109 2532 2959 3383 4209 25 18.5 - - - - 177 282 355 448 564 712 898 1134 1429 1687 2025 2367 2707 3368 30 22 - - - - 149 238 299 377 475 600 757 956 1204 1421 1706 1995 2281 2837 5 3.7 538 855 1364 2161 3362 7.5 5.5 381 606 966 1530 2380 3794 4770 10 7.5 291 462 737 1168 1817 2897 3642 4600 15 11 187 298 475 752 1169 1864 2344 2960 3728 4706 20 15 146 233 371 588 915 1458 1833 2315 2917 3682 4645 25 18.5 - - 297 470 731 1165 1465 1850 2330 2942 3711 4685 30 22 - - 245 388 603 961 1209 1526 1923 2427 3062 3866 40 30 - - - 295 459 732 920 1162 1463 1847 2331 2942 3707 4376 50 37 - - - - 358 571 718 906 1142 1441 1818 2296 2892 3415 4099 4792 5 3.7 108 172 274 434 676 1077 1354 1710 2154 2719 3431 4331 7.5 5.5 73 115 184 292 454 723 909 1149 1447 1826 2304 2909 3665 4327 10 7.5-88 141 223 347 554 696 879 1108 1398 1764 2227 2806 3313 3977 4649 15 11 - - - 154 239 382 480 606 763 964 1216 1535 1933 2283 2740 3203 3662 4556 20 15 - - - 116 181 289 363 459 578 729 920 1162 1464 1728 2074 2425 2772 3449 25 18.5 - - - - 141 224 282 356 448 566 714 901 1135 1340 1609 1881 2151 2676 30 22 - - - - - 188 236 298 375 474 598 755 951 1122 1347 1575 1801 2241 5 3.7 827 1316 2099 3324 7.5 5.5 578 920 1467 2323 3615 10 7.5 456 725 1156 1831 2849 4542 15 11 314 500 798 1264 1966 3134 3940 20 15 227 361 576 912 1419 2261 2843 3590 4523 25 18.5 181 288 459 728 1132 1805 2269 2865 3609 4556 30 22-244 390 617 961 1531 1925 2431 3063 3866 40 30 - - 288 457 711 1133 1424 1799 2266 2861 3609 4556 Lengths only meet the US National Electrical Code ampacity requirements for individual conductors rated 75 C in free air or water, NOT in magnetic enclosures, conduit or direct buried. Refer to NEC Table 310.15(B)(17) for more information. MCM equals circular mills of the wire x 1000

Cable Selection 9 CABLE SELECTION COPPER CABLE SIZE - From Service Entrance to Motor (Feet) MOTOR AWG MCM 60 C VOLTS /Hz HP KW 14 12 10 8 6 4 3 2 1 0 00 000 0000 250 300 350 400 500 SINGLE PHASE THREE PHASE 460 V 200-208 V 575 V 5 3.7 - - 210 332 517 825 1037 1309 1649 2082 2626 3315 4177 4931 7.5 5.5 - - - 216 336 536 674 851 1072 1353 1707 2155 2715 3205 3848 4498 10 7.5 - - - - 257 409 514 650 818 1033 1303 1645 2073 2447 2937 3434 3926 4884 15 11 - - - - - - 372 469 591 747 942 1189 1498 1768 2123 2482 2837 3530 5 3.7-213 339 537 835 1332 1674 2114 2663 3362 4241 7.5 5.5 - - 226 359 558 890 1118 1412 1779 2246 2833 3577 4506 10 7.5 - - - 274 427 681 856 1081 1361 1718 2168 2737 3448 4070 4886 15 11 - - - - 290 463 582 735 926 1169 1475 1862 2346 2769 3324 3886 4443 20 15 - - - - - 353 443 560 705 890 1123 1418 1786 2109 2532 2959 3383 4209 25 18.5 - - - - - - 355 448 564 712 898 1134 1429 1687 2025 2367 2707 3368 30 22 - - - - - - - 377 475 600 757 956 1204 1421 1706 1995 2281 2837 5 3.7 538 855 1364 2161 3362 7.5 5.5 381 606 966 1530 2380 3794 4770 10 7.5 291 462 737 1168 1817 2897 3642 4600 15 11 - - 475 752 1169 1864 2344 2960 3728 4706 20 15 - - 371 588 915 1458 1833 2315 2917 3682 4645 25 18.5 - - - 470 731 1165 1465 1850 2330 2942 3711 4685 30 22 - - - - 603 961 1209 1526 1923 2427 3062 3866 40 30 - - - - - 732 920 1162 1463 1847 2331 2942 3707 4376 50 37 - - - - - - 718 906 1142 1441 1818 2296 2892 3415 4099 4792 5 3.7-172 274 434 676 1077 1354 1710 2154 2719 3431 4331 7.5 5.5 - - 184 292 454 723 909 1149 1447 1826 2304 2909 3665 4327 10 7.5 - - - 223 347 554 696 879 1108 1398 1764 2227 2806 3313 3977 4649 15 11 - - - - 239 382 480 606 763 964 1216 1535 1933 2283 2740 3203 3662 4556 20 15 - - - - - 289 363 459 578 729 920 1162 1464 1728 2074 2425 2772 3449 25 18.5 - - - - - - - 356 448 566 714 901 1135 1340 1609 1881 2151 2676 30 22 - - - - - - - - 375 474 598 755 951 1122 1347 1575 1801 2241 5 3.7 827 1316 2099 3324 7.5 5.5 578 920 1467 2323 3615 10 7.5 456 725 1156 1831 2849 4542 15 11-500 798 1264 1966 3134 3940 20 15 - - 576 912 1419 2261 2843 3590 4523 25 18.5 - - 459 728 1132 1805 2269 2865 3609 4556 30 22 - - - 617 961 1531 1925 2431 3063 3866 40 30 - - - - 711 1133 1424 1799 2266 2861 3609 4556 Lengths meet the US National Electrical Code ampacity requirements for either individual conductors or jacketed rated 60 C cable and can be in conduit or direct buried. Flat molded and web/ribbon cable are considered jacketed cable. Refer to NEC Table 310.15(B)(16) for more information. MCM equals circular mills of the wire x 1000

Cable Selection 10 CABLE SELECTION COPPER CABLE SIZE - From Service Entrance to Motor (Feet) MOTOR AWG MCM 75 C VOLTS /Hz HP KW 14 12 10 8 6 4 3 2 1 0 00 000 0000 250 300 350 400 500 SINGLE PHASE THREE PHASE 460 V 200-208 V 575 V 5 3.7 - - 210 332 517 825 1037 1309 1649 2082 2626 3315 4177 4931 7.5 5.5 - - - 216 336 536 674 851 1072 1353 1707 2155 2715 3205 3848 4498 10 7.5 - - - - 257 409 514 650 818 1033 1303 1645 2073 2447 2937 3434 3926 4884 15 11 - - - - - 296 372 469 591 747 942 1189 1498 1768 2123 2482 2837 3530 5 3.7 134 213 339 537 835 1332 1674 2114 2663 3362 4241 7.5 5.5-142 226 359 558 890 1118 1412 1779 2246 2833 3577 4506 10 7.5 - - 173 274 427 681 856 1081 1361 1718 2168 2737 3448 4070 4886 15 11 - - - 187 290 463 582 735 926 1169 1475 1862 2346 2769 3324 3886 4443 20 15 - - - - 221 353 443 560 705 890 1123 1418 1786 2109 2532 2959 3383 4209 25 18.5 - - - - - 282 355 448 564 712 898 1134 1429 1687 2025 2367 2707 3368 30 22 - - - - - - 299 377 475 600 757 956 1204 1421 1706 1995 2281 2837 5 3.7 538 855 1364 2161 3362 7.5 5.5 381 606 966 1530 2380 3794 4770 10 7.5 291 462 737 1168 1817 2897 3642 4600 15 11-298 475 752 1169 1864 2344 2960 3728 4706 20 15 - - 371 588 915 1458 1833 2315 2917 3682 4645 25 18.5 - - - 470 731 1165 1465 1850 2330 2942 3711 4685 30 22 - - - 388 603 961 1209 1526 1923 2427 3062 3866 40 30 - - - - 459 732 920 1162 1463 1847 2331 2942 3707 4376 50 37 - - - - - 571 718 906 1142 1441 1818 2296 2892 3415 4099 4792 5 3.7 108 172 274 434 676 1077 1354 1710 2154 2719 3431 4331 7.5 5.5 - - 184 292 454 723 909 1149 1447 1826 2304 2909 3665 4327 10 7.5 - - 141 223 347 554 696 879 1108 1398 1764 2227 2806 3313 3977 4649 15 11 - - - - 239 382 480 606 763 964 1216 1535 1933 2283 2740 3203 3662 4556 20 15 - - - - - 289 363 459 578 729 920 1162 1464 1728 2074 2425 2772 3449 25 18.5 - - - - - - 282 356 448 566 714 901 1135 1340 1609 1881 2151 2676 30 22 - - - - - - - 298 375 474 598 755 951 1122 1347 1575 1801 2241 5 3.7 827 1316 2099 3324 7.5 5.5 578 920 1467 2323 3615 10 7.5 456 725 1156 1831 2849 4542 15 11 314 500 798 1264 1966 3134 3940 20 15-361 576 912 1419 2261 2843 3590 4523 25 18.5 - - 459 728 1132 1805 2269 2865 3609 4556 30 22 - - 390 617 961 1531 1925 2431 3063 3866 40 30 - - - 457 711 1133 1424 1799 2266 2861 3609 4556 Lengths only meet the US National Electrical Code ampacity requirements for individual conductors rated 75 C in free air or water, NOT in magnetic enclosures, conduit or direct buried. Refer to NEC Table 310.15(B)(17) for more information. MCM equals circular mills of the wire x 1000

THIS PAGE INTENTIONALLY LEFT BLANK

Warranty 12 Limited Warranty PENTAIR warrants to the original consumer purchaser ( Purchaser or You ) of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period shown below. Product Water Systems Products jet pumps, small centrifugal pumps, submersible pumps and related accessories PENTEK INTELLIDRIVE Pro-Source Composite Tanks Pro-Source Steel Pressure Tanks Pro-Source Epoxy-Line Tanks Sump/Sewage/Effluent Products PENTEK PENTEK submersible Motors, 6 diameter and larger XE-6 submersible motors, 6 diameter PENTEK single phase control boxes (for use with PENTEK XE-6 6 single phase submersible motors) Warranty Period whichever occurs first: 12 months from date of original installation, 18 months from date of manufacture 12 months from date of original installation, or 18 months from date of manufacture 5 years from date of original installation 5 years from date of original installation 3 years from date of original installation 12 months from date of original installation, or 18 months from date of manufacture 12 months from date of original installation, or 18 months from date of manufacture 12 months from date of original installation, or 24 months from date of manufacture 12 months from date of original installation, or 24 months from date of manufacture Our warranty will not apply to any product that, in our sole judgment, has been subject to negligence, misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a three phase motor with single phase power through a phase converter will void the warranty. Note also that three phase motors must be protected by three-leg, ambient compensated, extraquick trip overload relays of the recommended size or the warranty is void. Your only remedy, and PENTAIR s only duty, is that PENTAIR repair or replace defective products (at PENTAIR s choice). You must pay all labor and shipping charges associated with this warranty and must request warranty service through the installing dealer as soon as a problem is discovered. No request for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable. PENTAIR IS NOT LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER. THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN. Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights and You may also have other rights which vary from state to state. This Limited Warranty is effective June 1, 2011 and replaces all undated warranties and warranties dated before June 1, 2011. PENTAIR 293 Wright St., Delavan, WI 53115 Phone (262) 728-5551 Fax (262) 728-7323