Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure

Similar documents
Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42)

Flow Switch Diaphragm Style Flow Switch IFW5 10 N Diaphragm style flow switch. Thread type. Nil. Body size Note)

How to Order IFW5 10 N Diaphragm Style Flow Switch to 10 l/min NPT. Port size. Specifications. Contact. Port size

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

Transmitters: Relay Valve VR4151/4152

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Digital Flow Switch (Sensor Part) Operation Manual

Transmitters: Relay Valve

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

Pilot Operated 2 Port Solenoid Valve for Dry Air

3 Port Solenoid Valve Direct Operated Poppet Type

Pilot Operated 2 Port Solenoid Valve for Dry Air

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Suction Filter with Case. Specifications. Fluid Operating pressure Operating temperature Cover/Case. Model/Rated Flow Rate. Model

2-Color Display High-Precision Digital Pressure Switch

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

Non-Contact Sensor for Workpiece Placement Verification

Compact Proportional Solenoid Valve

Series VQ Port Solenoid Valve

2-Color Display High-Precision Digital Pressure Switch

Series IW. Filter Regulator

Clean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

HN B G1/US B G2/US B G3

25% reduction in volume * PB1013A/Air-operated type without foot

How to Order 02 1/4. Thread type Nil Rc N NPT * * Semi-standard

Coolant Valve. Air Operated/External Pilot Solenoid

: 660 N. For material handling and clamping of small workpieces. CKZT25 -X2797 (Base Type) Power Clamp Cylinder INFORMATION. ø

3 Port Solenoid Valve

For material handling and clamping of small workpieces

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

Standard Specifications

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

Series VP3145/3165/3185

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

CVE2/CVSE2 CVE3/CVSE3

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation

Miniature Regulator Series ARJ310

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

0.45 ms. 9mm. High Speed 2 Port Valve. SX10 Series. 2 mounting types

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Standard Specifications. Model. Indication precision. Clear cover. Brass Mass (kg) Bourdon tube. Model (Standard) Model G (2) G27-10-R1

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure

Speed Controller with One-touch Fitting AS13 1F-M3 AS13 1F-M5. Specifications

Standard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure

Safety Limit Switch

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

Series VP3145/3165/3185

Series CRQ2. Compact Rotary Actuator. Piping can be installed from one end. Body can be used as a flange Compact design saves mounting space

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

3 Port Solenoid Valve

Three types of flow range. 0.4 to 4 L/min (PF2D504) 1.8 to 20 L/min (PF2D520) 4.0 to 40 L/min (PF2D540) Swept flow characteristics (reference)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

High-Precision Digital Pressure Switch 90-ZSE40 /90-ISE40 Series

Standard Specifications

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Digital Flow Switch for Deionized Water and Chemicals Body and sensor New PFA Tube Super PFA

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

Base Mounted Metal Seal/Rubber Seal VQ0000 (VV5Q05) VQ1000 (VV5Q11) Individual SUP spacer. Individual EXH spacer

5 Port Solenoid Valve

General purpose direct acting 2, 3 port solenoid valve

Vacuum / Release Unit

Standard Specifications

New Concept Connector Type Manifold

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

Compact Slide. Series MXH ø6, ø10, ø16, ø20

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Rectangular Multi-connector. No. of Connecting Tubes: 10, 20. Plate. Plug connector Socket connector PAT.PEND

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

Inductive Proximity Sensor

Digital Flow Switch for Deionized Water and Chemicals

MYB1/MYG1 Series DC12V. Metal free 2, 3 port solenoid valve for chemical liquid

Electro-Pneumatic Regulator Electronic Vacuum Regulator

2-Color Display Digital Flow Switch

Advantages. Options VHS06

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8

Series ITV1000/2000/3000

Transcription:

Paddle Style For details about certified products conforming to international standards, visit us at www.smcworld.com. Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /B to B. Wide range of applicable fluids. Wetted metal part materials: Copper alloy, Stainless steel Various enclosures (No water protected). Open type, Dripproof/Rainproof, Splashproof /Low jetproof type How to Order Paddle style switch Enclosure IF N Open type Dripproof/Rainproof type (Equivalent to IP) ON- range to l/min to l/min to l/min Specifications Thread type Nil Rc N NPT Seal material of wetted parts NBR FPM Metal material for wetted parts CE-compliant Nil None Q CE-compliant Splashproof/Low jetproof type Brass, Phosphor bronze (Equivalent to IP) Stainless steel / Note ) IF is available for. Note ) IF and IF are available for. Fluid Max. pressure Water resistance Insulation resistance Withstand voltage Contact Standard Copper alloy Stainless steel Note) Suffix -Q to the end of product number when ordering. Water/Non corrosive liquid Liquid, which does not corrode stainless steel. MPa.7 MPa MΩ ( DC by megameter) VAC for one min. ab /, EN97-- Note ) Micro Switch Ratings Voltage VAC VAC 8 VDC VDC VDC VDC VDC Non inductive load (A) Inductive load (A) Load resistance Light load Inductive load Motor load N.C. N.O. N.C. N.O. N.C. N.O. N.C. N.O....................

Paddle Style Fluid and Ambient Temperature Range Enclosure Fluid temperature Applicable ambient temperature Note) Open type Using indoors away from water drop 7 C or less 7 C (7 C) or less C 8 C ( C) or less C 7 C ( C) or less C C ( C) or less Note) ( ) For IF To protect the microswitch, ambient temperature must be lowered when the fluid temperature exceeds 7 C. Dripproof/Rainproof type (JIS C ) Splashproof/ Low jetproof type (JIS C ) When using indoors or outdoors, where it is exposed to water drop. (Equivalent to IP) Sealed construction. When using in a bad environment, such as outdoors, or areas exposed to water stream temporarily, or near the coast. (Equivalent to IP) Construction Flow Characteristics Upper insulator Fluid: Water, Outlet pressure: MPa Sealing thread depth: 9 mm (/), mm () Micro switch Retaining screw Flow adjusting screw Retaining screw Flow switch Mounting Port size / Paddle size Flow range (l/min) Minimum ON OFF (min) 7 Maximum ON OFF (min) 8 ON- rate/setting (m/s). to.79 IF - / 8 9.8 to. /. to.8 to.7 / 7 7 to.7 /. to.9. to. IF - /. to.9. to.8 7 8. to.,, 87,.7 to.. to. PFM / / 8 7 7. to.. to.7. to.9 PFMV PFA Component Parts No. Description Cover Mounting plate Bellows Material IF IF IF SPCD SPCD ADC SPCC Stainless steel Stainless steel PBP or Stainless steel IF - / 7,,,.8 to..7 to. to.. to.9.9 to. PFW PFD IF 7 Body Mobile bar Paddle O-ring CB or Stainless steel C7W or Stainless steel XM7 Stainless steel NBR or FPM,,.7 to.8 ON-: Flow volume under which a microswitch starts activation while is increasing. OFF-: Flow volume under which a microswitch starts activation while is decreasing. The maximum is twice the maximum ON-. Data shows the reference value. Operating values may differ from those shown above as a result of sealing depth and direction of mounting, piping conditions or variations among individual items, so take precautions when using at levels near the minimum and maximum values of the set rate.

ON- Change due to Pressure Pressure Drop Curve. ON- change (%) Min. ON- Max. ON-....8. Pressure (MPa) Pressure drop (MPa).... /B pipe B pipe B, B pipe /, B, B pipe /B, /B, B pipe Flow speed (m/s) Precautions Be sure to read before handling. Refer to front matters 8 and 9 for Safety Instructions and pages 89 to 89 for Precautions. Caution Mounting & Wiring. Mount the switch on top of horizontal pipe so that fluid is in the direction of the arrow. Sealing depth should be 9 mm ± mm for /B and mm ±. mm for B.. Mounting orientation is only allowed to install it perpendicularly to the horizontal pipe.. Provide a straight pipe portion that corresponds to approximately times the bore of the pipe before and after the area of the pipe on which the product is installed, thus keeping the product as far away as possible from the elements that disturb the, such as elbows or valves.. Three types of paddles, short, medium, and long, are provided with each model. Use one of them according to the pipe size and the set rate.. When installing a paddle on IF O type, piping may be interfered with by the tip of a paddle. Because this is used to detect a small rate, and to narrow the distance between a paddle and piping, additional machining of the paddle tip may be necessary to eliminate interference between the two.. Use pipe fittings that comply with JIS specifications. For / B to B, use commercially available union tees of different diameters. For B to B, use a B socket that has been cut in half and welded. 7. When using piping which is non-standard, piping may interfere with the paddle. When this happens, please machine the paddle accordingly. 8. It cannot be used when a water hammer or pulsation pressure is applied to the fluid. Applicable fittings For pipe fitting / B through B For pipe fitting B through B Piping B / / / Reducing tees B / x / x / x / x x x / x / x x x Reducing tees: JIS B Socket : JIS B Pipe : JIS B Welding B socket cut in half Pipe B through B Welding or more Without flash 9. Wire the microswitch according to the symbols on the upper insulators. (They will be opposite the terminal symbols on the microswitch. The terminals are screw terminals.). Threads used for the terminals are M type. Internal wiring diagram Caution Adjusting Symbol C A B Contact Common Normally Open Normally Closed. Flow adjustment is done by turning the adjusting screw with Phillips screwdriver. Turning clockwise can increase the set and turning counterclock can decrease the set.. Flow rate % relation to the number of turns is shown in the table below. However, this is just a guide. For precise setting use a meter. Flow adjusting screw (Rotations) 7 8 9 Contact ON- (%) 9 8 7 8 89 9 9 98. The rate setting point is set at the ON- rate. Therefore, in case of a contact, ON signal is output when the fluid with higher than the setting rate is n. In the case of the b contact, the ON signal is output when the rate has decreased. Refer to the rate characteristics table for details on the operation rate.. Do not touch the two types of stop screws that are indicated in the construction diagram.. To prevent the chattering that is associated with the fluctuation of the operating rate, set the difference between the set rate and the operating rate so that it is as large as possible.. Use at or below the maximum operating pressure and maximum rate. 7. Spare parts, medium, and long paddles are provided as a piece set with each model, so arrange them as indicated below. There is no compatibility between the paddle for a /" connecting bore and for a " because their installation pitches differ. Arrangement example: Paddle set for IF-- (Part numbers are not existent.)

Paddle Style Standard type: // Dripproof/Rainproof type: // width across flats x ø holes width across flats x ø holes Part no. IF IF IF A B / 8 7 7 89 8 88 98 9 9 8 98 Part no. A B IF IF IF / 8 7 7 89 8 88 98 9 9 8 98 Splashproof/Low jetproof type: // PFM PFMV PFA PFW PFD IF width across flats G/ depth 7 Part no. IF IF IF A B / 8.. 7 89 8 9 9 9 8

Flow Rate vs. Flow Speed Representing value /B (ø.) B (ø7.) /B (ø.7) /B (ø.) B (ø.9) /B (ø7.9).8 Flow speed (m/s)....8 B (ø.7) B (ø.).. B (ø.8) B (ø.). Flow rate (l/min) ( ): Gas pipe bore sizes