Seismic Sensor Accessories SA, SV & ST 6000 Series

Similar documents
Proximity Transmitters, and Seismic Vibration Transmitters

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

NUMBER SIDE VIEW DESCRIPTION RANGE DIAMETER C F in. pf/ft. Coaxial, low noise, orange, PVC jacket

ELECTRICAL INSTALLATION

Proximity Transducers, Seismic Sensors and Accessories

Shell material Insulator Contacts Sealing Temperature Mating Protection

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

PPT 802, Proximity Probe Transducer System

Proximity Transmitters, and Seismic Vibration Transmitters

EPIC CIRCON M23 Series

Cable Glands & Accessories

General Cable Support Information

SKINNER Intrinsically Safe Series Four-Way

NTC Thermistor Assemblies

Junction Boxes Hazardous and Non-Hazardous

CATENARY ACCESSORIES INSTRUCTIONS. Power Management. Quick Connect Voltage Separation Box AY-QCVSB. Sheet 5. Suspension Accessories

User s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition

SAMPLE. Job Name: Anywhere Water District Construction of Reservoir Suggest'd Equipment Rent Total. Suggest'd Material.

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring

Section 3 Index Furnace Tube Skin Thermocouples

and Accelerometers Bently Nevada* Asset Condition Monitoring

Caution. Description. Specifications and Ordering Information and Accelerometers

Passive Speed Sensors

W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications

and Accelerometers

Explosionproof NEC. Features

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Liquid Tight. Liquid Tight Connectors Reusable Fittings. Straight Connectors. Straight Connectors with Insulated Throat

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Low Profile Insertion Vortex

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Glass Reinforced Polyester Enclosures

Hot Tap Insertion Vortex

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

Castle Model TSM-35. Heavy Duty Screw Pocket Machine. For Models with Serial Number and Above Items Included with Machine

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

PVC Couplings. Brass Couplings BRASS COMPRESSION COUPLING 3 -LENGTH PVC COMPRESSION COUPLING BRASS COMPRESSION COUPLING 5 -LENGTH

GO gets it. The all in one proximity sensor and limit switch.

APPLICATION MANUAL. Universal Explosionproof Two-Compartments Instrument Housing Type: XD-ID100, XD-ID100win, XD-ID100H, XD-ID100Hwin

Temperature Sensors Types MBT 5250, MBT 5260 and MBT 5252

LTX RF LEVEL SENSOR. Instruction Manual

Fluidizing Pickup Tube Kits

Sensor Mounting MACHINERY MONITORING. Mounting Configurations. Temporary Mounting

Insulator Connector inserts: Polyamide (PA66) UL 94 V0 All connectors with different shielding material for different jacket and shield diameters.

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.

Explosion Proof & Hazardous Area Junction Boxes

Conductor Size 18 TO 8 AWG, 6 TO 0 AWG, 2/0 TO 4/0 AWG, 4/0 AWG TO 750 MCM (ALUMINUM/COPPER CLAD, ALUMINUM/COPPER)

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

Myers Hubs. Standard Finishes: Aluminum: Natural Zinc: Natural Stainless: Natural

Shock/Vibration Control Switches

Amphenol Cable Glands and Cord Grips Amphenol

D-Sub adapter Cable entry protection with metric cable entries Cable entry protection with Pg cable entries

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

Solar Combiner Solutions

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Level Measurement Point level measurement - RF Capacitance switches

PIT, PIF & PIX. Features. Pressure-to-Current Transmitters

Wire Mesh. Flexible Cord. Liquid Tight Mesh Grips for Flexible Metal Conduit STR GT Series

A LOOK INSIDE MODEL 7 TECHNOLOGY IN ACTION 70 Series LEVERLESS LIMIT SWITCH GO Switch 70 Series end sensing switches use three permanent magnets and p

Type 2000 Transducer Product Instructions

Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box

Solenoid Valve Island Type 3965

EXBLI & EXBSPI Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments

MICRO-CON-X 2-7 NEW PRODUCT BULLETIN C708

americanfittingscorp.com t: e:

Magnetic-inductive flow meter for hazardous areas

INTERNATIONAL METAL ENGINEERING

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Electronic Temperature Sensor

User s Manual. Model MLA & MLD Loop Powered Process Indicators. Model MLD (Digital) Model MLA (Analog)

Parts Catalog. S-Series Slicer Standard Automatic S13A. Model:

Kuhlman Electric Corporation Volt Instrument Transformers

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

24W Explosion Proof POE Injector - Adds Power Over Ethernet Functionality to 24V POE Equipment - 1A

Metal LIQUID TIGHT CONDUIT FITTINGS & ACCESSORIES for Industrial Application

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223

Cable Festoon Systems - For Moving Machinery

Point level measurement Capacitance switches

AC METRIC (IEC) MOTORS THREE PHASE

Swagelok Ball Valve Actuation Options

CANBUS G. Up to mm ( in.) < ± 0.01% of full stroke or ± 0.04 mm ( in.), whichever is greater*

Corrosion Protection for Electrical Conduit and Fittings

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

W-Series Junction Boxes

MP461SC Flex Probes* Installation Instructions

Solenoid Valves Type 3963

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Armstrong In-Line and Insertion Vortex Flow Meters

Transmitter Housing Model: CET5000-G CET5000-P CET5000-P. Optional Extended cable For Remote Mounting. (6 or 12 feet length)

FIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications

Temperature Transmitters

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

Series 581 ISO Pneumatic Directional Control Valves

use pulldowns to assign fixture # to arm locations: K K K 14W LED 27W LED 1 Full-Cutoff optics

Transcription:

Seismic Sensor Accessories SA, SV & ST 6000 Series Part Number Name Used With Description Housing Material 7295-002 Accelerometer EP Housing SA6200A-X0X; SV6300A-001 Physical protection and access to 1/4-28 mount accelerometers. Rain tight & ex-proof for CSA Class 1, Grps A-D, Div.1. 1/4 NPT stud for mounting to machine case. 1 NPT top conduit union. Zinc Plated 7084-002 Flange Mount 7295-002 For surface mounting of 7295 housing. 1/4 NPT center hole. 3 equally spaced 6.6 (.26) dia. mount holes on 38 (1.50) dia. circle. 99506-020 99506-021 9061-XXXX Magnetic Mount Magnetic Mount Bulk Cable 99506-040 Mounting Pad SA6200A-X0X; SV6300A-001 SA6200A-X1X; SV6300A-011 8978-200-0000 SA6200A, ST6900 Series & SV6300A Strong rare earth magnet provides up to 16 kg [35 lbs] pull force for temporary mounting of 1/4-28 tapped accelerometers. Housing has 1/4-28 center hole & includes sensor mounting stud. Same as 99506-020 except metric version. Housing has M6X1 center hole and comes with matching sensor mounting stud..250 dia. bulk cable with twisted, shielded pair wires. For customer attachment to mating connector P/N 8978-200-0000. Specify - XXXX in 0.1 m increments (e.g. 9061-0250=25.0 m ). Mounting pad for magnet, 1 Polyurethane Jacketed 7295-002, Accelerometer EP Housing Assembled Disassembled 7084-002 Flange Mount 99506-040, Mounting Pad, 1 99506-XXX Magnetic Mount 125 mm [5.0 in.] Weight: 0.7 kg [1.5lb] Weight: 0.5 kg [1 lb] Weight: 0.5 kg [1 lb] Weight: 0. 25 kg [0.5 lb] 2.28

Seismic Sensor Accessories SA, SV & ST 6000 Series Mating Connector/Cable Assemblies 8978-111-XXXX, Splashproof Cable Assembly Two (2) pin socket connector with integral, molded splash proof boot with 6.4 mm (0.25 ) diameter polyurethane jacketed cable with twisted shielded pair wires. xxx.x = Cable length in meters. 9334-111-XXXX-YYYY, Splashproof Cable Assembly w/ Armor Two (2) pin socket connector with integral, molded splash proof boot with 7.1 mm (0.28 ) diameter, SST armored jacket with cable, twisted shielded pair wires. xxx.x = Armor length in meters. yyy.y = Cable length in meters. 8978-211-XXXX, Cable Assembly Two (2) pin socket connector with cable strain relief with 6.4 mm (0.25 ) diameter polyurethane jacketed cable with twisted shielded pair wires. xxx.x = Cable length in meters. Note: All 8978 connector/cable assemblies rated to 121 o C (250 o F) max. 9334-211-XXXX-YYYY, Cable Assembly, w/ Armor Two (2) pin socket connector with 7.1 mm (0.28 ) diameter, SST armored jacket with cable, twisted shielded pair wires. xxx.x = Armor length in meters. yyy.y = Cable length in meters. 8978-200-0000, Connector Assembly Two (2) pin socket connector with cable strain relief, no cable. 3719-002, Mounting Stud 1/4-28 UNF to 1/4-28 UNF 3719-007, Mounting Stud 1/4-28 UNF to M6 X 1 3719-008, Mounting Stud 1/4-28 UNF to 3/8-24 UNF 3719-009, Mounting Stud 1/4-28 UNF to 1/4-18 NPT 9338-101, Sensor Spot Facing Kit Tool with a 3/16 pilot and drill bits and taps NOTE: All 8978 connector/cable assemblies rated to 121 C (250 F) max. 2.29

Seismic Sensor Accessories Probe Driver / Signal Conditioner / Transmitter Housings Features Provides physical protection NEMA 4/IP 65 Models for 2, 4 or 8 units Conduit terminations (when used) Hazard rated - 2 or 4 unit models Metrix Product Applications 1 Signal Conditioner Models 5534 & 5544 (Pg 2.12) 5535 & 5545 (Pg 2.06) Signal Condtioner Models 5510, 5516 (Pg 1.26) Proximity Probe Transmitter Models TXA & TXR (Pg 1.20) Probe Driver Model 5533 (Pg 1.18) 1 Products (ordered separately) to be DIN-rail mount to fi t enclosures. Weatherproof Versions Polyester coated steel housing with gasketed cover and stainless steel clips comes with conduit hubs and DINrail/s for mounting Metrix Instrument Co. products. NEMA 4/IP 65 Model 7876-001 shown - 2 units (max. capacity) 1 NPT EXIT (Model 7876) (Model 8172) 1 1/4 NPT (Model 8173) 3/4 NPT ENTRY (QTY 2 for 7876) (QTY 4 for 8172) (QTY 8 for 8173) 7876-001 with 1 unit Explosionproof Versions Cast aluminum housing with threaded cover & DIN-rail/s for mounting Metrix Instrument Co. products. NEC & CSA rated for Class I, (C,D) & Class II (E, F & G), Div.1 areas. ATEX rating EEx d IIC T5 or T6. Explosionproof Model 7595-001 shown - 2 units (max. capacity) 3/4 NPT 1/2 NPT ATEX How To Select... Model Environmental Rating Units Empty Weight Dimensions in mm (inches) 7876-001 Weatherproof 2 2 kg (4.4 lb) 200 x 250 x 100 (8 x10 x 4) 8172-001 Weatherproof 4 3 kg (6.6 lb) 250 x 300 x 125 (10 x 12 x 5) 8173-001 Weatherproof 8 4 kg (8.8 lb) 300 x 350 x 150 (12 x 14 x 6) 7595-001 Explosionproof 2 5 kg (11 lb) 178 x 178 x 163 (7 x 7 x 6.4) 8156-001 Explosionproof 4 11 kg (24 lb) 280 x 229 x 190 (11 x 9 x 7.5) Note: Customized and pre-wired housings available upon request. Please contact us for more information. 2.30

Velocity Sensor Accessories 5485C PART NO. NAME USED WITH DESCRIPTION 8531-001 Mounting 5485C 1/4-28 mount adaptor - loose with screws and stud. (0.2 Kg) 8531-002 Mounting Same as -001 except shipped attached to sensor. 8531-XXX, Mounting 2.31

Transmitter Accessories ST5484E, ST5491E 8200-001, Conduit Elbow & Reducer Provides access and physical protection for fi eld wiring. Suitable for Class I, Div. 1 (Grps C & D) and Class II, Div. 1 (Grps E, F & G), hazardous areas. 1 to ¾ NPT reducer for customer connection included. NEMA 4 IP 65. Material: copper free aluminum. 8200-002, Conduit Elbow & Reducer Conduit Elbow with terminal block 8200-005, Conduit Elbow & Reducer Provides access and physical protection for fi eld wiring. 8200-006, Conduit Elbow & Reducer Conduit Elbow with terminal block 8201-001, Conduit Union Fits between transmitter and 8200-001 conduit elbow to facilitate installation and wiring where there is not enough room to rotate the elbow. Suitable for Class I, Div. 1 (Grps A, B, C & D) and Class II, Div. 1 (Grps E, F & G), hazardous areas. Material: zinc plated steel. 7084-001, Flange Mount Provides a means to surface mount transmitters rather than NPT stud (½ : NPT center hole). Three equally spaced 6.6 mm (0.26 ) diameter mounting holes on 38 mm (1.50 ) diameter circle. 7084-002, Flange Mount Same as 7084-001, except center hole is ¼ NPT. Material: stainless steel 8253-002, Bushing Bushing for ½ NPT mount when screwed onto standard ¼ NPT base. Material: stainless steel. 8169-75-002-XXX, Two-wire, Cable Assembly 2 conductor (20 AWG) twisted, shielded PVC jacketed cable, with plated steel grip for cable strain relief, male ¾ NPT end. Specify -XXX for length in feet. Example: 8169-75-002-010 =10 ft (3.1M). Material: zinc plated steel. 8978-111-XXXX, Splashproof Cable Assembly Two (2) pin socket connector with integral, molded splash proof boot with 6.4 mm (0.25 ) diameter polyurethane jacketed cable with twisted shielded pair wires. xxx.x = Cable length in meters. 9334-111-XXXX-YYYY, Splashproof Cable Assembly w/ Armor Two (2) pin socket connector with integral, molded splash proof boot with 7.1 mm (0.28 ) diameter, SST armored jacket with cable, twisted shielded pair wires. xxx.x = Armor length in meters. yyy.y = Cable length in meters. 8978-211-XXXX, Cable Assembly Two (2) pin socket connector with cable strain relief with 6.4 mm (0.25 ) diameter polyurethane jacketed cable with twisted shielded pair wires. xxx.x = Cable length in meters. Note: All 8978 connector/cable assemblies rated to 121 o C (250 o F) max. 9334-211-XXXX-YYYY, Cable Assembly, w/ Armor Two (2) pin socket connector with 7.1 mm (0.28 ) diameter, SST armored jacket with cable, twisted shielded pair wires. xxx.x = Armor length in meters. yyy.y = Cable length in meters. 8978-200-0000, Connector Assembly Two (2) pin socket connector with cable strain relief, no cable. 93818-004, Cable Grip Strain Relief Fitting 3/4 NPT male thread to cable grip. Diameter range:.156 to.25. Complete with sealing ring and locknut. Hot dip / mechanically galvanized fi nish. Suitable for NEMA 4 enclosures. 93818-018, Armored Cable Grip Strain Relief Fitting 3/4 NPT male thread to cable grip. Armor diameter range:.40 to.50. Complete with sealing ring and locknut. Hot dip / mechanically galvanized fi nish. Suitable for NEMA 4 enclosures. 2.32

Transmitter Accessories ST6900 Series & IT6810 8978-111-XXXX, Splashproof Cable Assembly Two (2) pin socket connector with integral, molded splash proof boot with 6.4 mm (0.25 ) diameter polyurethane jacketed cable with twisted shielded pair wires. xxx.x = Cable length in meters. 9334-111-XXXX-YYYY, Splashproof Cable Assembly w/ss armor Two (2) pin socket connector with integral, molded splash proof boot with 7.1 mm (0.28 ) diameter, ss armored jacket with cable, twisted shielded pair wires. xxx.x = Armor length in meters. yyy.y = Cable length in meters. 8978-211-XXXX, Cable Assembly Two (2) pin socket connector with cable strain relief with 6.4 mm (0.25 ) diameter polyurethane jacketed cable with twisted shielded pair wires. xxx.x = Cable length in meters. Note: All 8978 connector/cable assemblies rated to 121 o C (250 o F) max. 9334-211-XXXX-YYYY, Cable Assembly, w/ Armor Two (2) pin socket connector with 7.1 mm (0.28 ) diameter, ss armored jacket with cable, twisted shielded pair wires. xxx.x = Armor length in meters. yyy.y = Cable length in meters. 8978-200-0000, Connector Assembly Two (2) pin socket connector with cable strain relief, no cable. 3719-002, Mounting Stud 1/4-28 UNF to 1/4-28 UNF 3719-007, Mounting Stud 1/4-28 UNF to M6 X 1 8841-044, Mounting Stud 1/4-28 UNF to 1/4-18 NPT 3719-008, Mounting Stud 1/4-28 UNF to 3/8-24 UNF 3719-009, Mounting Stud 1/4-28 UNF to 1/4-18 NPT Note: These mounting studs are also used for 2-pin MS connector style accelerometers 2.33

Transmitter Accessories PMC/BETA 162VTS 7084-001, Flange Mount Provides a means to surface mount transmitters rather than NPT stud (½ : NPT center hole). Three equally spaced 6.6 mm (0.26 ) diameter mounting holes on 38 mm (1.50 ) diameter circle. 7084-002, Flange Mount Same as 7084-001, except center hole is ¼ NPT. Material: SS 8253-002, Bushing Bushing for ½ NPT mount when screwed onto standard ¼ NPT base. Material: stainless steel. 8169-75-002-XXX, Two-wire, Cable Assembly 2 conductor (20 AWG) twisted, shielded PVC jacketed cable, with plated steel grip for cable strain relief, male ¾ NPT end. Specify -XXX for length in feet. Example: 8169-75-002-010 =10 ft (3.1M). Material: zinc plated steel. 91174-036, Conduit Elbow & Reducer Provides access and physical protection for fi eld wiring. Suitable for Class I, Div. 1 (Grps C & D) and Class II, Div. 1 (Grps E, F & G), hazardous areas. 1/2 to 1/2 NPT reducer for customer connection included. NEMA 4 IP 65. Material: copper free aluminum. 8200-004, Conduit Elbow Conduit Elbow with terminal block, 1/2 to 1/2 NPT female. Supporting Accessories for MS Style Connector 93818-004, Cable Grip Strain Relief Fitting 3/4 NPT male thread to cable grip. Diameter range:.156 to.25. Complete with sealing ring and locknut. Hot dip / mechanically galvanized fi nish. Suitable for NEMA 4 enclosures. 93818-018, Armored Cable Grip Strain Relief Fitting 3/4 NPT male thread to cable grip. Armor diameter range:.40 to.50. Complete with sealing ring and locknut. Hot dip / mechanically galvanized fi nish. Suitable for NEMA 4 enclosures. 8841-058, 1 to 1/2 Reducer Retrofit adapter 2.34