SANWA Line (Europe Edition) Metallic Self - priming Magnet Drive Pumps MEK series Extensive Hydraulic Performance, Seal-less, Corrosion Resistant, Leak Free Catalog No. ISX-E-161-00
MEK Magnetic drive turbine pumps designed for process applications The MEK series stainless steel magnetic drive turbine pumps are free from leakage and are suitable for many applications involving transfer of organic solvents & other chemicals. TYPE MEK Motor output : 0,5 kw to,0 kw [Highly reliable block-building structure] High pump efficiency The self-centering design automatically positions the impeller for optimum efficiency. High Chemical resistance SUS 16 wet ends offer high chemical resistance for a wide range of chemical processes. Applications Chemical processes, laboratory use, test plants and pilot plants. D egreasing, water purification and seawater desalination plants. Food, beverage and pharmaceutical manufacture. Ultrasonic cleaning machines, medical equipment, industrial cleaning devices. 1
Construction and materials C 66 6 5 90A 0B 69101 61 6 100 5 5 B 8A 8 8C A 6 1 5 5 55 56 65 51 1 8B 15 : Magnet : Pressure vessel : Rotating parts : Bearings : Liquid immersed portion 101 COUPLING KEY(M) 1 100 MOTOR 1 69 NAME PLATE 0SS 1 66 HEXAGON HEAD BOLT & NUT 16SS 65 HEXAGON HEAD BOLT 16SS 6 HEXAGON SOCKET HEAD CAP SCREW 16SS 6 HEXAGON HEAD BOLT 16SS 6 HEXAGON HEAD BOLT 16SS 6 61 SET SCREW STEEL 5 DISCHARGE NOZZLE 16SS 1 56 CHECK VALVE 16SS 1 55 SUCTION NOZZLE 16SS 1 5 GASKET PTFE 1 5 PLUG 16SS 1 5 PLUG 16SS 1 51 PLUG 16SS 1 5 BUSHING SiC C GASKET PTFE 1 B O RING PTFE 1 A O RING PTFE 1 0B MAGNET COUPLING(M) STEEL 1 0A MAGNET COUPLING(P) 16SS 1 1 SPACER 16SS 1 15 FRAME ADAPTER CAST IRON 1 9 SLEEVE SiC-D 8C RETAINING RING 16SS 1 8B COUPLING KEY(P) 16SS 1 8A IMPELLER KEY 16SS 1 8 SHAFT 16SS 1 TOLERANCE RING 16SS REAR CASING 16SS 1 CASING COVER 16SS 1 CASING 16SS 1 1 IMPELLER 16SS 1 MARK NAME OF PART MAT'L No. Significance of SiC-D - Increased damage prevention -» SiC-D bearings can withstand accidental dry run for certain periods.» Unique materials and manufacturing techniques of our specially treated SiC-D bearings provide a coefficient of friction 1/ that of SiC.» The very low coefficient of friction of our SiC-D bearings results in much less heat being generated in upset or dry running conditions. SiC-D bearings are more forgiving of dry running conditions frequently encountered at start up, during upset conditions or in batch services. Extremely hard surfaces minimize wear and prolong service life; resistance to chemicals is maintained for extended bearing life. BUSHING (SiC) SLEEVE (SiC-D)
Specifications MODEL MEK01 MEK51 MEK MEK Bore 0mm (Rc/) 5mm (Rc1) mm (Rc1-1/) mm (Rc1-1/) Motor Output 0,5kW P 0,kW P 1,5kW P,kW P,0kW P,0kW P Capacity x Head (L/min x m) 50Hz 9 x10 1 x 0 9 x 1 0 x 5 Note: DIN or JIS flange is available as an option. 0,55kW P motor for MEK51 is available as an option. 60Hz 1 x 1,5 16 x 0 x 9 60 x Max. S.G. (Standard : 1,) Application base : 1,9 Max. Viscosity (mpa s) (Standard : 0) Application base : 10 Design Pressure (MPa G) 1,0 Applicable Temperature ( C) -0 ~ +10 Selection charts MEK 0,5kW~,0kW 50Hz MEK 0,5kW~,0kW 60Hz 60 50 60 50 0 0 TOTAL HEAD (m) 0 10 6 5 MEK51 MEK01 MEK MEK TOTAL HEAD (m) 0 10 6 5 MEK01 MEK51 MEK MEK 0 10 0 0 50 60 0 90 100 CAPACITY (l/ min) 0 10 0 0 50 60 0 90 100 CAPACITY (l/ min) Pump Type Identification MEK01-6 TS KD 05 [1] [] [] [] [5] [1] Pump Size "01" / "51" / "" / "" [] Pump Material "6": 16SS [] Check Valve Material "TS": PTFE + 16SS [] Bearing Material "KD": SiC & SiC-D [5] Motor Output "05": 0,5kW P / "0": 0,kW P / "15": 1,5kW P / "":,kw P / "0":,0kW P / "":,0kW P
Outline dimension A D B SUCTION s k I DISCHARGE d t f H g h ROTATION e W BOLT HOLES -øfd d c b a MODEL MEK01 MEK51 BORE SIZE 0mm (Rc/) 5mm (Rc1) MOTOR OUTPUT (kw) 0,5 0, MOTOR FRAME 1 1 H A B D W a b c d e f g h k l 60 6 11 16,5 50 19 10 6,5 1 1 8,5 1 1 1 150 90 95 5 50 150 90 100 90 0 96 t 1 1 (In the unit of mm) PUMP only FD approx weight (kg) ø1 ø1 15,5 19 MEK mm (Rc1-1/) 1,5, 90 1 16 151,5 6,5 1 10 15 15 6 150 9 90 1 ø1,5 MEK mm (Rc1-1/),0,0 100 11 6 16,5 165,5 0 0 00 16 0 0 15 15 9 5 18 ø1 Dry running protector DRN series (Option) Model DRN is electric current sensing type dry running protector. It detects the decreased load current (lower limit) to stop the pump when it runs dry or runs with air sucking in. It can detect overload, too. Specifications MODEL DRN-01 DRN-0 Amperometric range Unit s source voltage Operating temperature Operating humidity Current sensor Analog input 1 Analog input Temperature range Digital contact input Contact output Logging capability Communication Supported models External dimension in mm 0-0,00A 0-00,0A AC100-V 50/60Hz 10VA 0- C 5-85%RH JS10FL JSFL -0mA or 1-5V -0mA or 1-5V -50-00 C (Pt100,K thermocouple) No-voltage contact signal (also for external reset) For pre-alarm: AC50V 8A (load resistance) 1c For pump-stopping: AC50V 8A (load resistance) 1a Past records (with the calendar) RS85 incorporated M, MMP, MP, MTFO D1 x W108 x H90 * Not used as an inverter. * Safty: UL 61010-1 * EMC: EN616-1 CAN/CSA-C. No. 61010-1-1 * RoHS: EN50581 EN61010-1 EN616-1, EN50581