Name of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal. TENDER SCHEDULE -1-1 2 3 4 5 6 7 1 208 Point Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. including all charges for cleaning and painting the walls using suitable colour of paint. 2 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including all connections but excluding modular plate etc. as required. including cleaning and painting the walls using suitable colour of paint. One Point 2.a 140 s 5/6 amps switch 2.b 140 s 3 pin 5/6 amp socket outlet 2.c 21 s Telephone socket outlet
3 15 s Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required including all charges for concealing the box and cleaning and painting the exposed surface with suitable colour of paint. 4 55 s Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. including all charges for concealing the box and cleaning and painting the exposed surface with suitable colour of paint. 5 49 s Supplying and fixing 2 module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. 6 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. as required including all charges for concealing the box and cleaning and painting the exposed surface with suitable colour of paint. 6.a 57 s 3 Module (100mm X 75mm) 6.b 15 s 6 Module (200mm X 75mm)
6.c 15 s 8 Module (125mm X 125mm) 6.d 20 s 12 Module (200mm X 150mm) 7 47 s Supplying and fixing brass batten/ angle holder including connection etc. as required. 8 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable ( Red, Black & Green )in the existing surface/recessed steel/ PVC conduit as required including cleaning and painting the walls using suitable colour of paint. 8.a 600 3 x 4 sq. mm One 8.b 650 3 x 2.5 sq. mm One 8.c 980 3 x 1.5 sq. mm One 8.d 300 6 x 6 sq. mm One
9 6 Supplying and fixing 6 way (8 + 18), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar,earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)including all charges for concealing the DB and cleaning, and painting the surface with suitable colour of paint. 10 2 s Supplying and fixing of 8 way (8 + 24), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required including all charges for concealing the DB and cleaning, and painting the surface with suitable colour of paint. 11 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 11.a 80 s Single pole 11.b 6 s Triple pole
12 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 12.a 6 s 40 amps 12.b 2 s 63 amps 13 4 s Supplying and fixing 2 + 12 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) including all charges for concealing the DB and cleaning, and painting the surface with suitable colour of paint. 14 4 s Supplying and fixing 40 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 15 10 s Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
16 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 16.a 6 s 40 amps 16.b 2 s 63 amps 17 Supplying and fixing of following sizes of medium class ivory colored PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per the direction officer at site. 17.a 460 20 mm One 17.b 140 25 mm One 17.c 120 32 mm One 18 49 s Supplying an fixing of 1200 mm sweep electric energy efficient star rating branded fan, with double ball bearing, shackles, down rod, canopies, blades suitable for operation on 240 V, 50 Hz Single phase AC Supply. 19 90 s Supplying and fixing of 15 watt LED bulbs
20 80 s Supplying and fixing of 28 watt LED tubes 21 16 s Supplying and fixing of Exhaust fan of following sizes complete with all fixing materials, interconnections etc. 200mm sweep 230V, shutter type medium duty Including cutting holes, finishing the surface as per direction of department officer at site. 22 1000 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable (1 run) in the existing surface/ recessed steel/ PVC conduit as required as per direction of department officer at site. 23 150 Supply and fixing of 1.1 kv grade 3½ x 35 sq mm Aluminium conductor XLPE insulated PVC sheathed power cable as required including with all accessories with end glanding as required. (From panel board to DB) 24 300 Supply and laying two number of the 10 SWG good quality bare copper wire on surface for loop earthing along with the existing XLPE insulated aluminium cable as required.(from panel board to DB) 25 Charges for preparing plans for getting approvel from electrical inspectorate of extra additional load of the KASRS Building, but excluding the fees. TOTAL One One One IN WORDS
LIST OF APPROVED MATERIALS Sl MATERIALS & SPECIFICATIONS MAKE 1 FRLS PVC insulated single core stranded copper wire / three core flexible cable 2 Modular type switch / socket / electronic stepped fan regulator / blanking plate / G.I. box / UPVC box / metal base and cover plate 3 MCCB / RCCB / MCB / MCB. Blanking plate 4 Double door horizontal type / vertical type TPN/ MCCB / 4way metal enclosure DB 5 SPN industrial type socket outlet with metal enclosed plug top Finolex / RR Kabel / V Guard / BCH MK - Wraparound / Myrius / Siemens- Delta Legrand / Siemens / ABB 6 LED tube/ LED fittings Philips/ Bajaj/ Crompton Greeves/ 7 PVC conduit / accessories, medium Precision / Konseal / Balco / A1 Plast 8 1.1kV Al XLPE Cable Ralison/ Gloster/ Havells 9 Ceiling fan/ Exhaust fan Bajaj/ Crompton greaves/usha/ Havells te: 1 In case any obvious mistake in the schedule of the items which can be easily identified, the contractor shall not take advantage of these errors and department reserves the right to correct these errors whenever they are noticed after formally bringing it to the notice of the contractor during the period of contract.