Dual-Needle Infinity II Upgrade Kit

Similar documents
Agilent InfinityLab LC Series Multi-wash Upgrade Kit

Agilent 1290 Infinity Autosampler

Agilent 1290 Infinity II Ultra Low Dispersion Kit

Agilent Online-SPE Direct Inject Kit G4744A

Agilent G5632 Valve Kit Instructions

Agilent G4239C Valve Kit - Instructions

Agilent 210/218 - Isocratic Pump

Agilent InfinityLab Quick Change Valve G4237A

Agilent 210/218 - Binary Pump

Agilent Valve Kit G4231A/B/C and G4232B/C/D

Agilent Valve Kit G4231A/B and G4232A/B/C

Agilent InfinityLab 2D-LC Solution with mass spectrometric detection and diverter valve

Agilent InfinityLab LC Series 1260 Infinity II Fraction Collectors

Agilent InfinityLab Quick Change Valves G4231A/C and G4232C/D

Agilent G4236A 2D-LC Valve Installation Guide

Agilent InfinityLab LC Series 1260 Infinity II Delay Coil Organizer

Agilent SD-1 Purification System ml/min

Agilent InfinityLab Quick Change Valve G4235A Instructions

Agilent 1200 Series Valves

Agilent 1260 Infinity Manual Injector

1260 Infinity II Multicolumn Thermostat

Agilent 218 Purification Solution

Agilent 1200 Series Manual Injector

Agilent 1260 Infinity Standard Autosampler

Agilent 1200 Series High Performance Autosamplers & Micro Well Plate Autosampler

Please exercise care when using solvents close to the instrument. It could damage the vapor sensor present in the ELSD.

Agilent 1290 Infinity Multisampler

Installation of the 2 position/10 port valve into the 1100 series thermostatted column compartment

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

Impurity Testing of Fixed-Dose Combination Drugs Using the Agilent 1290 Infinity II HDR-DAD Impurity Analyzer Solution

Installation Note for Solvent Selection Valve Upgrade Kit (G1360A)

10 Maintenance. Agilent Technologies. This chapter describes the maintenance of the module Infinity Binary Pump User Manual

Agilent 1290 Infinity Quaternary Pump

Agilent 1200 Series Standard and Preparative Autosamplers

Installation Guide. Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A

Application Note. Authors. Abstract. Energy & Chemicals

Agilent 1260 Infinity Bio-inert High Performance Autosampler

Installing the 6850 Direct Valve Column Connector Kit

Agilent 1260 Infinity Bio-inert Manual Injector

Agilent 1290 Infinity Binary Pump

Agilent InfinityLab LC Purification Solutions SELECTION GUIDE

Agilent 1290 Infinity Quaternary Pump

Agilent 1260 Infinity Quaternary Pump VL

Installing the Flame Ionization Detector EPC Flow Control Manifold

Agilent 1260 Infinity Binary Pump VL

HPLC Model 210D. UV detector lamp switch. Rheodyne 7725i injection valve. Prime/purge valve. Column. compartment. thumbscrews. Storage.

Agilent 1260 Infinity High Performance Micro Autosampler

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

1260 Infinity II SFC System

CHROMATOGRAPHY. SYKAM S 6000 Valve Series

TECHNICAL REPORT. Introduction. Agilent 1100 HPLC system. Figure 1: HALO columns exhibit UHPLC-like performance at conventional HPLC pressure

The Agilent 1200 Series high perfor- mance autosampler SL: Area precision, injection volume linearity, minimum accessible volume, carry-over

Agilent 1200 Series Preparative Pump

Installing a Purged Packed Inlet

1260 Infinity II Degasser User Manual. 5 Maintenance

Installation Guide. Thermal Conductivity Detector on a 6850 GC Accessory G2623A

Valve Box and Valve Accessories G4315A, G4316A, G4317A

Chromatography. Liquid. HPLC Accessories SupelPRO Valves SUPELCO

Agilent G1554A On-Column Capillary Inlet with EPC

Installing a Cool On-Column Inlet

System Manual. Agilent 1260 Infinity Capillary LC System

G1160A Agilent 1100 Series Multiple Purpose Switching Valve

Installation Guide. Flame Ionization Detector on a 6850 GC Accessory G2621

Dionex AS-DV Autosampler Preventive Maintenance Procedure

Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011

Agilent 1200 Series Thermostatted Column Compartment G1316A/G1316B/G1316C

Agilent SD-1 Isocratic Solvent Delivery Module

Torque Module Installation and User Guide for model 250i Motorcycle Dynamometers.

Agilent 1200 Series Nano Pump

Your Essential Resource for INFINITYLAB LC SUPPLIES

Needle OD (mm) Needle ID (mm) Needle Gauge

Installing a Purged Packed (PP) Inlet

Installation Guide. Auxiliary Pressure Control Manifold on 6890 GC Accessory G1570A

seal, needle seat, needle assembly, seat cap kit Includes: rotor seal, needle assembly, needle seat 1100 G kit 25271

Nickel Catalyst Tube Accessory 19205A

Agilent 1100 Series Capillary LC System. System Manual

SITRANS F. Ultrasonic Flowmeters. Hi-Precision Mounts. Operating Instructions. Answers for industry.

Neueste LC Entwicklungen

Installation Guide. Flame Ionization Detector on a 6890 GC. Accessories G1561A, G1562A, G1591A, G1598A

Agilent 1100 Series Isocratic Pump. Reference Manual

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell

Agilent 1100 Series Thermostatted Column Compartment. Reference Manual

SPEEDKEY KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev Page 1 of 9. GEM e2, e4, e6, el XD

Performance Characteristics of the Agilent 1260 Infinity II Bio-Inert LC

Motor Valve MV-7/IMV-7

Brake Line Replacement Instructions, Saleen 14-inch Brake Kit For S281/Mustang

Hi-Z USB Wireless. Introduction/Welcome

PATROL UPLC Process Analysis System for Production

Application Note. General Use Inlet Solvent Filters. Inlet Solvent Filters. Filters and Degassers. New!

Open Center Compact Valve Custom Installation Guide Rev A

Agilent 1260 Infinity Analytical SFC System

Agilent Capillary Electrophoresis System. User s Guide

18SP709Rev Page 1 of 8

Technical Overview. Introduction

Online sample cleanup on the Agilent 1290 Infinity LC using a built in 2-position/6-port valve

Agilent 1200 Series Capillary Pump

GX-271 ASPEC Gilson, Inc. All Rights Reserved. LT

235/235P Autoinjector User's Guide

ACQUITY UPLC I-Class System with 2D Technology

User Manual Infinity II High Temperature GPC System

Transcription:

Dual-Needle Infinity II Upgrade Kit Installation Note General Information The Dual-needle Upgrade Kit is designed for very fast injection for high throughput and unmatched flexibility to obtain the best configuration for very small as well as very large injection volumes without any compromises on analysis time or performance. This upgrade kit can be installed in any Agilent InfinityLab LC Series Multisampler. Figure 1 Valve in mainpass (right), drawing sample with left needle Agilent Technologies

General Information Figure 2 Capillary connections (Dual Needle Option) If the Multisampler dual-needle option is installed you will lose the ability to do multi-draw. 2

Delivery Checklist Delivery Checklist Make sure all parts and materials have been delivered with the upgrade kit. Report missing or damaged parts to your local Agilent Technologies sales and service office. # p/n Description 2 G4267-87012 High Pressure Needle Seat, 0.12 mm (PEEK) 2 G4267-87201 Needle Assembly 1 G4267-60311 Sample Loop 20 µl right Dual needle for 1290 Infinity II Multisampler 1 G4267-60301 Sample loop 20 µl left Dual needle for 1290 Infinity II Multisampler 1 G4267-60511 Sample Loop 100 µl right Dual needle for 1260 Infinity II Multisampler 1 G4267-60501 Sample loop 100 µl left Dual needle for 1260 Infinity II Multisampler 1 G4267-60044 Needle Port Assembly Station 1 G7167-60000 1260 Dual-Needle Upgrade Hydraulic 1 5067-4256 3pos/6port Peripheral Valve DN 1300 bar 1 5067-4260 2pos/8port Injection Valve Dual Needle 1300 bar 1 G4267-60043 Analytical Head, 100 µl 1 5500-1225 Capillary ST 0.12 mm x 180 mm SL-SL 1 5500-1226 Capillary ST 0.17 mm x 180 mm SL-SL 1 5500-1227 Capillary ST 0.17 mm x 150 mm SL-SL 1 5500-1228 Capillary ST 0.3 mm x 80 mm SL-SL 1 5500-1229 Capillary ST 0.3 mm x 180 mm SL-SL 1 G7167-60007 Hydraulic 1260 Dual Needle The installation of the upgrade kit is divided into three parts: removing the standard or multi-wash hydraulic box, see Remove the Hydraulic Box on page 4, installing the dual-needle hydraulic box, see Install the Hydraulic Box on page 5, configure the dual-needle feature in the CDS, see Configure the Dual Needle Instrument Method in OpenLab C.01.06 and Above on page 10. 3

Remove the Hydraulic Box Remove the Hydraulic Box Tools required Preparations Description Wrench 1/4 inch Hexagonal key, 2.5 mm Torx screwdriver Tx 20 Switch off the instrument. 1 Remove the capillaries, the tubings, and the leak sensor which are connected to the hydraulic box. 2 Press the pusher to unlock the needle assembly. 3 Remove the needle assembly and sample loop from the single needle instrument. Keep the needle seat. 4 Lift the clip (bottom of the hydraulic box) before you pull out the whole hydraulic unit. 4

Install the Hydraulic Box Install the Hydraulic Box 1 Install the dual-needle hydraulic box. Be careful that the hydraulic box is installed correctly and fits exactly in the main chassis. 2 Open the screw of the needle parkstation adapter (needle port adapter) and remove the needle parkstation adapter. 3 Install the second needle port assembly into the needle station on the left side. 5

Install the Hydraulic Box 4 Install the dual-needle sample loops, the second needle assembly, the second needle seat, the tubing and the leak sensor which are connected to the dual-needle hydraulic box. Figure 3 Capillary connections (Dual Needle Option) Be careful when installing the capillaries. Do not mix up the capillary position. Only use dual-needle parts to avoid harm to the instrument later. 6

Install the Hydraulic Box 5 Install the right needle assembly and push the adapter behind the pusher to lock the needle assembly correctly in the parkstation. 6 Check the correct installation: The left dual needle sample loop in the rear position, and the right dual needle sample loop in the front position. 7 Switch on the Multisampler. 7

Configuration of the Dual-Needle Option in the CDS Configuration of the Dual-Needle Option in the CDS The configuration of your controller is not necessary to enable the dual-needle mode. In the GUI you will see the new multi-wash icon. 1 Configure the correct dual needle sample loops in the CDS system. The hardware configuration must match the software configuration to avoid harm to the instrument. 8

Configuration of the Dual-Needle Option in the CDS 2 Prime the tubing with appropriate wash solvent. 3 Purge the multisampler to flush all capillaries with start condition. For 1290 Infinity II systems this will be done automatically if you start the pump flow. For 1260 Infinity II systems you have to do that manually. Depending on the configuration the purge time can vary. 4 Perform a pressure test for the left and the right flow path in Lab Advisor. 9

Configuration of the Dual-Needle Option in the CDS Configure the Dual Needle Instrument Method in OpenLab C.01.06 and Above 1 Select Instrument in the menu. 2 Select Setup Instrument Method. 3 Under Needle selection, you can select between right, left or alternating needle (depending on your configuration). For OpenLab CDS, LC driver A.02.12 or higher is required. 4 In alternating needle mode, Smart Overlap is available. The the next sample is drawn with the other needle after a set time past the current injection. In contrast to overlapped injection, the flow path is flushed (carry-over reduction) 5 Overlapped injection is available, if two different loops or a bypass capillary are installed. 10

Configure the Bypass mode (Dual Needle option unused) in OpenLAB C.01.06 and Above Configure the Bypass mode (Dual Needle option unused) in OpenLAB C.01.06 and Above This setup is useful if you want to avoid long purge time. If only one path is used on a regular basis, a defined bypass capillary can shortcut one path to allow faster reconditioning. First the instrument hardware must be changed, see Figure 4 on page 11. The bypass capillary is installed either on the right or the left flow path. For the left bypass capillary, the connection from port 1 to port 5 has to be used. For the right bypass the capillary connection from port 3 to port 7 has to be used. Figure 4 The right bypass capillary is installed Only the listed capillary PN 5500-1238 can be used as bypass capillary (either left or right). 11

Configure the Bypass mode (Dual Needle option unused) in OpenLAB C.01.06 and Above 1 To set up the bypass capillary in the CDS, right-click into the active area, then select Modify > Capillaries from the context menu. 2 Select Right or Left from the Bypass capillary dropdown menu, depending on which flow path you want to bypass. In the active area, you will see the new multi-wash icon. Click Assign. 3 Select Instrument in the menu. 4 Select Setup Instrument Method. 5 Under Needle selection, select either Right Needle or Left Needle (depending on your bypass capillary). The hardware configuration must match the software configuration to avoid harm to the instrument. *G7167-90220* *G7167-90220* G7167-90220 Rev. C Edition: 04/2017 Printed in Germany Agilent Technologies, Inc 2016, 2017 Agilent Technologies, Inc Hewlett-Packard-Strasse 8 76337 Waldbronn Germany