QUALITY THERMOMETERS CALIFORNIA USA. javelin

Similar documents
javelin PRO QUALITY THERMOMETERS CALIFORNIA USA

AF-200. Large Capacity Automatic Pet Feeder. User instruction CAUTIONS: SPECIFICATIONS:

fax

TRACER. POCKETESTER ä ORP CODE 1742

WS-9116U Wireless 433 MHz Temperature Station. Instruction Manual

industrial thermometers INDUSTRIAL THERMOMETERS

24 LED SOLAR CAMPING LANTERN

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

Bottom Loading Water Dispenser

Tracer ORP PockeTester TM Code 1742

INSTALLATION MOTORIZED COUPLED SHADE

Touchscreen Thermometer & Timer model 00398

SoilStik ph Meter PRODUCT MANUAL. Item # 2105

28W WORK LAMP Model: CTL28 Part No:

Care and use guide. Contents. page

IMPORTANT SAFETY INSTRUCTIONS VP200ESK SAFETY INSTRUCTIONS 1

ISOCAL - 6 Range Europa Venus Calisto

PH60 Series Premium ph Testers

Window Thermometer models / / 00423

Beamex MB METROLOGY TEMPERATURE BLOCK. Portable temperature dry block delivering bath-level accuracy for industrial applications

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

752 Recipe Converter Instruction Manual

Weather Thermometer models 00754/00771W/00772W/00773W/00774W

Instruction Manual. Single-Input Thermistor Thermometer (Model )

User s Manual. Forest Adventure Playset TM VTech Printed in China US CA

OPERATING INSTRUCTIONS

Remote Control Engine Starter System Owner s Manual

Instatherm ACE. The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and heating mantles.

Thermometer models / 00831A

For technical questions and replacement parts, please call

BASEWEST Operating & Maintenance Manual. Model TS-420 Test Set. 28 September 2010

INSTRUCTION BOOKLET. Rechargeable Salt & Pepper Mill SP-2

100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY

Portable Digital Luggage Scale. Model: NC-A2

Thermocouple Thermometer Models

Assembled Parts. Terminal Base. Barn Roof. Air Track with Tabs. 2 Barn Walls. Barn Base. 4 Air Tracks with Connectors. Air Track with Support

PC60 Premium Multi-Parameter Tester (ph/ec/tds/salinity/temp.) Instruction Manual. APERA INSTRUMENTS, LLC V6.4

Sherman + Reilly Battery-powered Pistol Grip Cable Cutters

Marin Control Digital

Thermometer models 02023/02028/02053/02054

Wipers and washers Wipers and washers WINDSCREEN WIPERS Intermittent variable delay CAUTIONS Note: Speed dependent mode 103

Care and use guide. Contents. page

PHscan10S Pocket ph Tester Instruction Manual

FOR YOUR PERMANENT FILE

DIGITAL TORQUE WRENCH. Useful Instructions

USER S GUIDE WARRANTY. This manual and all information contained herein is copyright HM Digital, Inc. ONE YEAR LIMITED WARRANTY

Wireless Thermometer model 00782W

SRK12KX Battery-powered Crimping Tool

GATOR Battery-powered Pistol Grip Cable Cutters

operating manual DL7 101 DIGITAL THERMOMETER

ENC-560 Autosampler Enclosure

Thermistor Thermometer MODEL NO

Multistage Air Filtration Systems Instruction Manual

4V LITHIUM-ION SCREWDRIVER OWNER S OPERATING MANUAL

User s Manual. 3-in-1 Launch & Play Raceway TM VTech Printed in China

Thermometer models 00592W / 00592A

Intelligent Charging System. User Manual PB-80C24

5-Piece Grill Tool Set WITH DIGITAL THERMOMETER

Visit us at

Professional. Owner s Manual. Heavier Use Bottled Water Dispenser #601177

Instatherm ACE. The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and heating mantles P.

OWNER S MANUAL. 16 Stand Fan Model: SF-16T07

Digital Body Weight Scale Model No.: EB4074C. Questions or Concerns? (855)

DT304. Digital Temperature Logger INSTRUCTION MANUAL

Infrared Thermocouple Probe

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

CATEYE URBAN WIRELESS+

Instructions for 4616 KYB shock rebuild and valve installation:

Solar Power Light Meter

12.0-Volt Lithium-Ion Power Source

Temp-14 Single Input Thermistor Thermometer

82V LITHIUM-ION BATTERY CHARGER GC 400

Braun ThermoScan PRO 6000 Thermometer Inservice MC

ITEM # V LITHIUM-ION CHARGER MODEL #KRC Español p. 6. ATTACH YOUR RECEIPT HERE Serial Number. Purchase Date

V1945Z OWNER S GUIDE.

OPERATOR'S MANUAL. Cat. No. C12 PC. To reduce the risk of injury, user must read and understand operator's manual.

1200W CaR PoliSheR en RS4900

WARRANTY. Illustration

Digital Body Weight Scale Model No. EB4074C. Questions or Concerns? (855)

Digital Body Weight Scale

NEC Versa FX Battery Packs

Thermometer model 00826

FLP-2492/KLP-4492 Impeller Flowmeter

SMX 92 & SMX 152 Installation and Operating Guide

TMA5 Mini Vane Anemometer

Wireless Thermometer model 00380

Gator Pet 18V Let s get started

Single-Input Thermocouple. Thermometers Type J, K, T

60V RECHARGEABLE LITHIUM-ION BATTERY

EGOLD-1000 Electronic Grease Level Detector

Specification Approval Sheet

Thermometer models 02023, 02028, 02029

AUTORANGING RESISTANCE INDICATOR

User s Manual. Deluxe Car Carrier TM VTech Printed in China

EC1 Pocket Conductivity Tester Instruction Manual

INSTALLATION GUIDE MANUAL SHADE

NOTES TABLE OF CONTENTS

MANUAL TPMS CRX 1002/1003

PHscan30S Pocket ph Meter Instruction Manual

Transcription:

QUALITY THERMOMETERS CALIFORNIA USA javelin

YOUR JAVELIN 03 04 Javelin F 01 02

01 PROBE 18/8 food grade stainless steel 02 LCD large readout display 03 MAGNET for easy storage 04 LANYARD hole for quick attachment

GETTING STARTED Extend the probe and the Javelin is ready for use. Sleep Mode If you leave the Javelin on and idle for more than 60 minutes, the device will automatically go to sleep. To get it going again, simply retract and extend the probe. Javelin

Javelin MODEL: PT12 CHANGING THE BATTERY When the display shows ERROR and the icon, it s time to switch out your battery. Fully retract the probe and twist open the battery door with a coin. C R 2 0 3 2 LAVATOOLS. CALIFORNIA Assembled in China Carefully remove existing battery and insert a new CR2032 with the positive (+) pole up.

SWITCHING BETWEEN C /F Personalize your Javelin using the C / F switch found inside the battery bay. Simply twist open the battery door and tap out the battery to access the switch. F C

ADDITIONAL INFORMATION Magnetic Backing The Javelin has a built-in magnetic backing to allow for convenient storage. Magnetic backing may not work on stainless steel surfaces. Splash Resistant The Javelin is rated at IP65 splash resistance. This means that it is protected against low pressure jets if water, such as splashes from a tap.

Tapered Sensor Tip The ultra-sensitive thermistor sensor is located at the tip of the probe, requiring a minimum insertion distance of 0.25 (5mm). Antimicrobial Coating Silver-based antimicrobial additive is impregnated into the plastic shell to inhibit the growth of pathogens. Efficacy is rated at 99% or greater.

ACCURACY TEST To check the accuracy of your Javelin PRO, we recommend using an ice bath test. To create an iced bath, fully pack a large cup with crushed ice. Next, fill 3/4 of the cup with purified water. Let the slurry sit for a brief moment and give it a quick stir to allow the temperature to equalize throughout. Insert the tip of the probe into the very center of the cup and stir gently. In 3 to 4 seconds, the display will read within 1 F (0.5 C) of 32 F (0 C).

TROUBLESHOOTING WON T SWITCH ON DISPLAYING ERROR DEVICE ASLEEP retract and extend probe or change battery battery is running low, change batteries retract and extend probe to wake

USE & MAINTENANCE Do not insert the probe all the way to the plastic collar Always measure at the center of the meat, avoid hitting bone or hard cartilage Prevent bacterial growth by wiping down the probe after each use Clean the body with soft damp cloth. Do not use solvents or scouring agents Do not put the device in the dishwasher This device is exclusively intended for the field of application described in this manual. It should only be used as described within these instructions. Abuse, water damage, modification, or accidental breakage to the product will void all warranty.

SAFETY WARNING Never leave the device in the oven Never place probe directly over fire Never immerse the device in liquid for any period of time Keep the device and battery out of reach of children Do not subject the device to extreme temperature, vibration, or shock Batteries must not be thrown into the fire, short-circuited, taken apart or recharged

LAVATOOLS.CO come visit us for more info