A Comparison of Typical UPS Designs in Today s Markets

Similar documents
Multilink Transportation Power Solutions

Embracing the Challenge of the Broadband Energy Crisis

Questions Section: Do you have questions that aren't covered? Please contact us!

JOINT SERVICE POWER EXPO CLARY CORPORATION

ULTRACAPACITORS FOR UNINTERRUPTIBLE POWER SUPPLY (UPS)

The nine power problems

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

THE SEMI CONDUCTOR INDUSTRY VERSUS VOLTAGE SAGS. Power. Made Perfect. SM THE CASE FOR AGGRESSIVE INTERVENTION

Power Protection Discrete Automation & Motion South Africa

Model #: APS V DC or 120V AC input; 120V AC output (hardwired) Auto Transfer Switching option for battery backup / UPS operation

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Installation and Operation Manual Back-UPS BR800/1100CI-IN

Aurora Single Phase Emergency Lighting Inverters

Installation and Operation Back-UPS BX550CI-CN

Using Inverter Input Modes for Smart Grid Management

HOMER OPTIMIZATION BASED SOLAR WIND HYBRID SYSTEM 1 Supriya A. Barge, 2 Prof. D.B. Pawar,

Model #: APS3636VR. 36V DC or 120V AC input; 120V AC output (hardwired)

Qnergy PowerGen Unattended Remote Power Solutions for the O&G Industry

GE Critical Power. The Retrofit Case for Upgrading Legacy Power Systems at Telecom Central Offices

Power Conditioning of Microgrids and Co-Generation Systems

P-Box. Pre-Assembled Off-Grid Power Cabinets. All-in-One Power Cabinet for Off-Grid Solar Power Systems

How To Set Up SimpliPhi Batteries Using OutBack Chargers

KEYS TO RUNNING YOUR GENERATOR EFFICIENTLY

ABB Data Center Solutions Day 5 July 2013 by Kelvin Sim Myths or Truths: Achieving 99% Efficiency with Single Conversion Backup Power System

Standby Inverters. Written by Graham Gillett Friday, 23 April :35 - Last Updated Sunday, 25 April :54

PowerVerter 750W RV Inverter/Charger with Hardwire Input/Output

Optimization of Total Operating Costs Using Electric Linear Drives

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Uninterruptible Power System

Achieving the Highest Power Density in the Smallest Footprint

Uninterruptible Power System

Model #: RV1012ULHW. 12V DC or 120V AC input; 120V AC output (hardwired)

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

400/230 Volt 60Hz UPS Power

Battery Storage Systems

VOLTAGE SAGS; A LITTLE STORAGE CAN GO A LONG WAY

B&B Power. We hope to establish a long-term business relations with you

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

OFF-GRID Hybrid (BI-DIRECTIONAL) SOLAR INVERTER SOLAR INVERTER SOLAR UPS

ABB life cycle services Uninterruptible power supplies

1250W 12VDC PowerVerter Ambulance/EMS Inverter/Charger with 2 Hospital Grade Outlets

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Modular UPS «AGIL» Stay on! Changing the rules for critical business continuity :

Uninterruptible Power System

On-grid or off: We carry the load

Technology from the New Product SANUPS K for a Smart Grid Society

NorthStar Battery Company DCN: SES DCR: 1548-S09 Date:

COMPANY PROFILE & PRODUCT SHOWCASE. Power Anytime Anywhere

High Effective Availability Decentralized UPS HEAD-UPS (c) 3.0 High Effective Availability Decentralized UPS-HEAD-UPS(c)

How to Select an Inverter for Your Needs

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Standby Power Systems

Gay E. Canough. OFF-GRID Design. Dr. Gay E. Canough, Master trainer. Living Off the Grid

Flywheel Energy Storage

Optimal Design Methodology for LLC Resonant Converter in Battery Charging Applications Based on Time-Weighted Average Efficiency

Alphapower HTU UPS. Some key features include:

DC Arc-Free Circuit Breaker for Utility-Grid Battery Storage System

Topics we re going to cover in the presentation

Food power. ABB s rugged UPS PowerLine DPA ensures food and beverage production facilities keep running

Off-grid Power for Wireless Networks. Training materials for wireless trainers

P-Box & E-Box AC Series

INVERTER. basics. by Christopher Freitas

Using OutBack Inverters for 3-Phase 480V Applications

Micro Lighting Inverter

Optocouplers Help Promote Safe, Efficient EV Charging Stations

Description Sets the priority for the AC source (AC1 or AC2) for qualification and transfer.

ANALYZING POWER LOSSES AND THEIR EFFECTS IN COMPLEX POWER SYSTEMS

SESL H - THREE PHASE AC VOLTAGE STABILISERS & REGULATORS. SESL H SERIES - THREE PHASE to 1500 kva. AC THREE PHASE TO 1500 kva

Technology that Evolves in Line with Market Changes

FN Series Scalable N+1 UPS 3kVA to 24kVA Rackmount

Energy storage - two Canadian Case Studies ESA Annual Conference, Washington, June 4th. Alex Bettencourt Managing Director

Battery to supply nonstop energy to load at the same time contingent upon the accessibility of the vitality sources. In

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Battery Bank for Wind Turbine. Project Proposal Prash Ramani, Marcos Rived TA: Katherine O Kane

BUILDER S GUIDE TO AUTOMATIC HOME STANDBY GENERATORS

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Design Modeling and Simulation of Supervisor Control for Hybrid Power System

Guidelines for Modernizing Existing Electrical Switchgear in LV and MV Networks

Using Inverter Input Modes for Smart Grid Management

Development of Higher-voltage Direct Current Power Feeding System for ICT Equipment

SILICONES GLOBAL SOLUTIONS

Cochran Undersea Technology

AcuBMS Battery Management System for Rechargeable Lithium-Based Batteries ELECOMP Capstone Design Project

PCS AC POWER LINE CONDITIONERS. PCS H SERIES - THREE PHASE - 6 to 500 kva H - THREE PHASE SERVO ELECTRONIC DESIGN. AC - THREE PHASE - 6 TO 500 kva

Vehicle Impact due to E- Mobility 5. Bayerischer Innovationskongress 23.June 2016 Techbase

GUIDE TO BACK UP POWER

GLX. Series. 1kW to 16kW Central System

Three-Phase Power Conversion in a Single Step

Emergency Station Power

The Tanktwo String Battery for Electric Cars

LEADING BATTERY ENERGY STORAGE SOLUTIONS AVAILABLE FROM FREEDOM WON (DATA SHEETS AVAILABLE UPON REQUEST) Freedom Lite Home & Business

Your Needs. Our Technology.

UPS Ratings-Not so Apparent

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

WHY STACO ENERGY PRODUCTS?

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

DPA 250 S4 (50 kw 1,500 kw) The most energy-lean UPS on the market MODULAR THREE-PHASE UPS SYSTEMS. The most energy-lean UPS on the market

off-grid Solutions Security of supply Basics: Off-grid energy supply

System Diagram Examples. Page 5 Page 11 Page 15

Transcription:

A Comparison of Typical UPS Designs in Today s Markets An Alpha Technologies White Paper by Kevin Binnie, Senior Product Portfolio Manager March 1, 2011

2 White Paper: A Comparison of Typical UPS Designs in Today s Markets Executive Summary: At its most basic, an Uninterruptible Power Supply (UPS) is designed to provide backup power to support continuing operation of electrical or electronic devices in the event of a power failure. Today s UPS systems usually also provide some level of power conditioning and protection against fluctuations in voltage from the grid. There are four types of UPS architectures in use today: Online or Double Conversion, Line Interactive, Offline and Controlled Ferro-Resonant (CFR). Each has its own merits and drawbacks, depending on the application. Offline For backup applications where low cost is critical, it doesn t matter if the load loses power briefly and backup times are short, an offline solution is adequate, although it will not provide adequate protection against spikes or sags from the grid. Controlled Ferro-Resonant For applications that require complete isolation from any changes in grid power, such as many medical applications, a controlled ferro-resonant solution offers the best solution. Online or Double Conversion For applications where power losses due to inefficiencies are less of a concern and eliminating the delay from grid power available to back power is paramount, Online (also called Double Conversion) is the only solution. Line Interactive For typical applications where power often needs conditioning but is usually available and very short transfer times from grid to backup power are acceptable, and daily energy consumption is a concern, Line Interactive is the preferred solution.

3 White Paper: A Comparison of Typical UPS Designs in Today s Markets Offline A typical offline backup power supply will continuously provide power with some filtering (typically the same as on a surge protection power strip) from the utility. When utility power fails, the device will start its internal inverter, and then mechanically transfer from utility power to inverter output. This transfer can take as long as 25 ms, which may be too long for some loads. An Offline UPS will transfer to battery backup during brownouts or surges as well. Typical offline runtimes in backup mode are from a few minutes to 20 minutes and extended runtime battery packs are rarely available. Pros Low cost: can be widely implemented in an organization Small size: unobtrusive Simple design: little or no training required to understand full functionality Cons No power conditioning Slow transfer time Simple battery charger may shorten battery life and increase recharge time Limited additional functionality may not meet enterprise needs Short back-up time Figure 1: Offline UPS Block Diagram Filter in Transfer Switch Battery Charger Battery Inverter out DC

4 White Paper: A Comparison of Typical UPS Designs in Today s Markets Line Interactive Figure 2: Line Interactive UPS Block Diagram Transformer with Tap Selector Utility Input Filter UPS Output Bi-Directional Converter DC Battery Bank During normal operation, the Line Interactive UPS takes utility power and passes it through a transformer with various tap selections on the output. When utility power is high, the Line Interactive UPS selects a tap to lower (buck) the output voltage. Similarly, when the utility voltage is low, the UPS selects a tap to increase (boost) the output voltage. Combined with additional internal protection and filtering circuits, the Line Interactive UPS provides filtered and regulated power out with a minimum of internal power loss. When the utility voltage becomes out of the range that the buck/boost transformer can support, the UPS switches to battery power, usually within a few milliseconds. Since the majority of electronic equipment today is able to continue operating without power for a few ms, this does not present a problem in most applications. Pros Low cost Sine wave output Wider input range Buck and boost regulation Efficient Surge protection EMI/RFI/Noise suppression Cons Minimal load protection 4-6 ms transfer time Spike and surge protection components degrade over time

5 White Paper: A Comparison of Typical UPS Designs in Today s Markets Controlled Ferro Resonant UPS A Controlled Ferro Resonant UPS operates in the same manner as a line interactive UPS, however its transformer can hold the voltage on the load side long enough for the inverter to begin providing input power, eliminating transfer time. It also provides complete isolation from input to output, protecting against all kinds of noise. A Ferro-resonant UPS can operate over a wide range of input voltages, however due to the low frequency design of the transformer, it can be large and heavy compared with other UPS types. Pros Best spike and surge protection with complete output isolation Zero transfer time On-line power 100% Power conditioning Input power factor correction Better output flexibility Longer service life expectancy Cons Larger/Heavier Higher heat output More expensive Can be problematic with power factor corrected loads 1 Figure 3: Controlled Ferro Resonant UPS Block Diagram Ferro Control Voltage Sense Current Sense Continuous Filtered Regulated Output Power 1 Power factor is the portion of power delivered to the load that is actually used. A non-power factor corrected load will draw more power than one which is power factor corrected. Most modern electronics use power factor corrected power supplies.

6 White Paper: A Comparison of Typical UPS Designs in Today s Markets Online (Double Conversion) The Online or Double Conversion UPS continuously rectifies incoming power to DC power to supply the internal DC bus of the UPS. The output inverter takes the DC power and produces regulated power to support the critical load. During an outage, the inverter continues to operate, drawing power from the batteries and the load sees no transfer time. Due to the fact that there are two active stages of power conversion operating continuously, the online UPS is less efficient than its line interactive and CFR counterparts. It also has a shorter life expectancy due to continuous operation of all components. Online UPS manufacturers often work to get around the inefficiency issue by increasing the DC bus voltage level. This means that the battery voltage has to increase correspondingly, resulting in a greater number of batteries and introducing a higher risk of failure due to the larger number of batteries. Pros Zero transfer time Excellent surge and noise suppression Constant voltage output 100% power conditioning Input power factor correction Cons Higher heat output More expensive Lower efficiency No neutral conditioning Low MTBF Shortened battery life Figure 4: Online or Double Conversion UPS Block Diagram Statis Disconnect Switch Utility Charger Inverter Utility Load Battery

7 White Paper: A Comparison of Typical UPS Designs in Today s Markets Choosing a UPS In choosing a UPS there are a number of considerations that will point to one design over another: Efficiency Most security loads today are designed to withstand up to a 30 msec loss of power. High quality line interactive solutions offer transfer times as low as 3-5 msec, and operate at a much higher efficiency than online units - as much as 10% - whenever grid power is available. A 10% savings in energy over the course of a year for multiple installations can add up to a significant savings to the user. For example, at a single location, there might be up to 50 installations of 500 W loads. An online UPS will typically operate at 85% efficiency or less, so to power these loads, (50* 500 = 25 kw), the user must select online units that are drawing 15% more power: over 29 kw. Over a year assuming an average price per kwh of 10 cents, this adds up to over $3,800 in a single year at one site. Users can realize a significant savings and reduce their carbon footprint by choosing a line interactive solution over double conversion. Durability An Online UPS continuously converts power from to DC and back again, putting unnecessary stress on power conversion components all of the time. By contrast, a Line interactive unit will only use the power components to charge the batteries if necessary or when there is a power failure or extended degradation a few times per year. Since all these components have a finite operating design life, it is reasonable to assume that a unit which uses those components less often will last longer. Other Considerations Regardless of the type of UPS, there are several other factors that merit consideration: Is the system subject to extremes of weather? A line interactive solution designed to meet -40 C to +74 C conditions is required by many users with outdoor backup power needs, whereas typical online solutions are designed for indoor (controlled environment) use: 0 to 40 C is typical. Interestingly, outages occur most often during weather extremes, so it s important to make sure that the UPS is designed to operate when you need it most. Is the air quality poor? Electronic components that are subjected to dust and high moisture levels will fail unless they are designed to meet these conditions. A well designed cabinet combined with a system that uses extreme grade components and conformally coated boards will survive in harsh environments that leave indoor systems wanting. Is there easy access to the unit? If the unit is remotely installed, a UPS that requires more frequent maintenance can cost considerably more by requiring more truck rolls and unnecessary maintenance activities. While all systems require some level of maintenance, it s important to select one that minimizes maintenance.

8 White Paper: A Comparison of Typical UPS Designs in Today s Markets How long do outages last in my area? A Berkeley National Laboratory study conducted in 2004 indicates that on average in the US, events last around 1 hour and 45 minutes. 2 Longer outages make it more important to select a UPS designed for extended runtimes and one that supports fast recharge times of batteries to ensure rapid availability of battery power after an outage. Conclusion: While there are a wide variety of considerations in selecting a UPS, in general, a Line Interactive UPS offers the most cost effective solution for the majority of applications. Only in those applications where zero transfer time is critical does an online UPS become the preferred choice. When choosing a UPS, key considerations include required runtime, environmental conditions and expected outage duration. 2 Understanding the Cost of Power Interruptions to U.S. Electricity Consumers Kristina Hamachi LaCommare and Joseph H. Eto http://eetd.lbl.gov/ea/emp/emp-pubs.html

9 White Paper: A Comparison of Typical UPS Designs in Today s Markets About the Author Kevin Binnie is the Senior Product Portfolio Manager at He has over 20 years of professional management experience, including 10 years of product management experience with over 8 years in power electronics and battery based solutions. Kevin holds a Computer Engineering degree from the Royal Military College of Canada and an MBA from Simon Fraser University and has worked with industry leading technology companies including Nokia, Xantrex, Colligo Networks and Spectrum Signal Processing. About Alpha Technologies is an established leader in the design, manufacture, service and installation of powering solutions for the Telecom, Traffic, ITS, CATV, Security, Medical, Industrial, and Renewable Energy industries. The Company offers a broad portfolio of high-quality, feature-rich solutions that can be customized to suit almost any application and environment, offering the highest performance and best value in the industry. With a focus on being your power solutions partner, Alpha builds on over 30 years of outdoor power manufacturing experience to develop solutions that solve customers unique powering challenges. As a member of The Alpha Group, ATL is part of a global alliance of companies that share a common philosophy to create world class powering solutions for communication, commercial, industrial and renewable energy markets.