Communication module. Brief description. Block structure Features. Page 1/5. Data Sheet

Similar documents
Logic module. Brief description. Features. Block structure. Data Sheet Page 1/5

Analog input module. Brief description. Page 1/8. Data Sheet

J TS 7090 Thyristor power switch

Pressure Transmitter JUMO dtrans p30 Type

JUMO safetym TB/TW Temperature limiter, temperature monitor according DIN EN

JUMO BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

Thermostats for panel mounting Series ETH

General section System Manual Part 1

Explosion-protected surface-mounting Thermostat ATH-Ex Series

JUMO heattherm Type a Protection temperature limiter, as a panel-mounting thermostat a Compensated for ambient temperature

Pressure transmitter JUMO dtrans p02

Measuring Cells for free chlorine, chlorine dioxide, ozone

JUMO tecline H2O2 JUMO tecline PAA Sensor for hydrogen peroxide and peracetic acid

Immersion fittings. Brief description. Installation options Standard. Series Page 1/7. Data Sheet

JUMO DSM software. PC software for management, configuration, and maintenance of digital sensors. Operating Manual T90Z001K000

Surface-mounting Thermostats Series ATH-SW

JUMO tecline Ci-S. Inductive conductivity and temperature sensor for general process engineering. Installation Instructions T94Z001K000

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft

Operating manual. LabStation LS Flex/430

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

KNC-SRV-FD123-CA-000 Series Servo Driver

Features and Benefits. Certifications

Motor Starter Reverse MSR22-FBP

Lexium integrated drives

Low voltage AC drives

Hydraulic Valves «DSV»

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

Industrial furnaces. Innovative solutions for your success

JUMO ecotrans Lf 01/02

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Modular electrical and pneumatic automation system

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

ABB i-bus KNX DG/S x DALI-Gateway Basic

Level and Flow Measurement. Sludge Finder 2

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

INVEOR "Smart connections." on five levels

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

USERS MANUAL MCD REMOTE OPERATOR

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

PKS-FD Servo System

DATA SHEET Genset Control Unit, GCU 100

KNC-SRV-FD123-EA-000 Series Servo Driver

SME S.p.A. Via della Tecnica, n Arzignano (VI) - ITALY Phone:+39 (0444) Fax: +39 (0444)

Product Flyer ELC ELECTRONIC LAMP CONTROL

BRAQCPC IT T. Goulds Pumps AQUAVAR CPC. Variable Speed Centrifugal Pump Controller. Engineered for life

See «Overview of types»

KNC-PKS-FD S-AAK-DKH

High performance Vector Control. Ratings. System configuration

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

SolarMax S series (Australia) Maximising solar plant yields can be so easy.

PowerCommand. ModLon II Gateway. Specifications. ModBus LON Converter

PowerCommand 500/550 Remote Monitoring System

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

mass flowmeter for compressed air

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

EUROPE RA-SERIES. Arc welding robots up to 10 kg payload

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

2017 Advanced Energy Industries, Inc. THYRO-S DIGITAL THYRISTOR SWITCH 8 TO 350 A

SonoMeter 30 Energy Meters

User Manual Rittal PMC UPS 6kVA

Lexium integrated drives

PLC Stamp mini 2 Datasheet

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

The motor starter on the power bus. Solutions for conveyor technology. Full speed ahead

JUMO digiline ORP. Intelligent electronics with digital interface or analog output for redox sensors. Operating Manual T90Z001K000

Service Training. Audi A5 - Networking. Self-Study Programme 395

Fieldbus System Variations

SonoMeter 30 Energy Meters

Ball valve for pipeline systems

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

VAHLE POWERCOM 485. Digital Data Transmission System

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Automated Precision Weighing

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

Modular pneumatic valve unit

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

VAHLE POWERCOM 485. Digital Data Transmission System

D509E. Manual Motor - Starters

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

Product information. ORION-PB Poultry computer for floor keeping

Liebert PowerSure PSI UPS

Field IT Actuators & Positioners. Intelligent Electric Modulating Actuator. Contrac RHD Intelligent Electric Modulating Actuator

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC

EVG1200W/10A PHplus-R3

X11CA-IM MASTER MODULE

Altivar 31 AC Drives. Simply Smart! For 3-phase asynchronous motors from 0.25 to 20 HP

SolarMax S series (United Kingdom) Maximising solar plant yields can be so easy.

ELECTRIC ACTUATORS. for industrial applications and civil vessels ELEKTRISCHE STELLANTRIEBE

DGC-2020 DIGITAL GENSET CONTROLLER

DS DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL

Transcription:

M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 (0) 661 60 03-7 25 Fax: +49 (0) 661 60 03-6 81 E-Mail: mail@jumo.net Internet: www.jumo.de JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM20 2TT, UK Phone: +44 (0) 12 79 63 55 33 Fax: +44 (0) 12 79 63 52 62 E-Mail: info@jumoinstruments.fsnet.co.uk JUMO PROCESS CONTROL INC. 735 Fox Chase Coatesville PA 19320, USA Phone: 610-380-8002 1-800-554-JUMO Fax: 610-380-8009 E-Mail: info@jumousa.com Internet: www.jumousa.com Data Sheet 70.4040 Page 1/5 Communication module Brief description This unit is a module of the JUMO mtron control and automation system. The plastic housing measures 91mm x 85.5mm x 73.5mm (W x H x D) and is mounted on a standard rail. The module is used for communication between the JUMO mtron modules and higherlevel units with MODbus or Jbus interface. The communication module has a LON interface with FTT-10A transceiver for linking to the JUMO mtron installation and either an RS232, RS422 or RS485 interface for data transmission under the MODbus protocol. A setup interface is provided for parameter setting and configuration of the module via a PC under the JUMO mtron-itool project design software. The electrical connection is made through plug-in screw terminals. Block structure Features Type 704040/0-... Visualisation via MODbus Connection to PLC via MODbus Configuration and parameter setting via JUMO mtron-itool project design software Modem operation for configuration and setting parameters of a JUMO mtron automation system over any distance Several communication modules can operate in a network Automatic dialling of a telephone number via modem on alarm in the LON network Integral RS232, RS422 or RS485 interface

Page 2/5 Displays and controls (1) Service LED, red - lights up on operating fault - flashes when the mechanical connection to the module from JUMO mtron-itool or the operating unit is being checked by a test handshake signal ( wink ) (2) Switch for the termination resistance of the LON network Input Analogue 16 variables real type 4 variables long type Logic 8 variables bool type 1 modem alarm bool type Function: They are linked to any network variable of other mtron modules (3) Installation key the module reports to the JUMO mtron-itool project design software or the operating unit (4) Setup interface for the PC interface line which links the module to the PC (5) Power LED, green lights up when the supply is switched on Output Analogue 16 variables real type 4 variables long type Logic 8 variables bool type Function: They can be written as output network variables of the communication module via MODbus. General data Environmental conditions to EN 61 010 Operating and ambient temperature: 0 55 C Permitted storage temperature: -40 to +70 C Relative humidity: rh 80% max. Pollution degree 2 Overvoltage category 2 Housing Material: plastic, self-extinguishing Flammability Class: UL 94 VO Protection: IP20 (to EN 60 529) Mounting: on standard rail 110 240 V AC +10/ 15 %, 48 63Hz, or 20 53V AC/DC, 48 63Hz Power consumption: 5VA max. Network (LON interface) Transceiver: free topology FTT-10A Topology: ring, star, line or mixed structure Baud rate: 78 kbaud Max. lead length (depending on lead structure): line: 2700m star: 500m ring: 500m mixed: 500m Max. number of modules: 64 Operation and project design Operation, parameter setting and configuration of JUMO mtron modules can be carried out from the JUMO mtron operating unit. The JUMO mtron-itool project design software permits convenient design and start-up of a JUMO mtron system. The projects can be archived and documented. Individual modules are linked via LON by assigning network variable (NV) names..

Page 3/5 Connection diagram Module underside with plug connectors Connector II Connector I Connector II Connection for Terminals Notes Diagram RS232,,B4,,B5 RxD TxD CTS RTS RS422 RS485,,B4,,B5 TxD A TxD B RxD A RxD B RxD/TxD A RxD/TxD B LON interface 3 = TE screen 4 = Net_A 5 = Net_B any polarity Connector I Connection for Terminals Notes Diagram as label,bl1,bn,bte AC line neutral technical earth } any polarity,bl1 DC,BN,BTE technical earth

Page 4/5 Dimensions Isolation Ordering details (1) (2) 704040/0-.. -.. (1) Outputs..... Outputs Interface RS232 51 Interface RS422 52 Interface RS485 53 (2)..... Type 110 240 V AC +10/-15%, 48 63Hz 23 20 53 V AC/DC, 48 63Hz 22 Standard accessory 1 Installation Instructions M 70.4040 Accessories PC interface with TTL/RS232C converter for connecting the module to a PC; length 2m. Sales No. 70/00301315 Project design software JUMO mtron-itool Using the JUMO mtron- itool project design software the modules can be designed graphically on the PC. The user is able to link modules of the JUMO mtron family and to configure the applicationspecific parameters. System Manual JUMO mtron Documentation of configuration, parameter setting and installation of the modules. Sales No. 70/00334336 JUMO mtron modules Controller module Data Sheet 70.4010 Relay module Data Sheet 70.4015 Analogue input module Data Sheet 70.4020 Analogue output module Data Sheet 70.4025 Logic module Data Sheet 70.4030 Operating unit Data Sheet 70.4035 Communication module Data Sheet 70.4040 Project design software JUMO mtron-itool Data Sheet 70.4090

Page 5/5 Communication module (gateway) Brief description The mtron to PROFIBUS-DP gateway is an all-in-one unit with a switched-mode power supply, data transmission module (transceiver), controller (Neuron 3150) and a fieldbus controller in a compact case (with a bracket for mounting on a standard rail, if required). The fieldbus controller acts as a slave to link up with PROFIBUS-DP. The gateway serves to link an mtron network with any number of mtron modules to a PROFIBUS-DP network as a PROFIBUS-DP slave. The automatic baud rate recognition enables baud rates of 9.6, 19.2, 93.75, 187.5, 500 and 1500 kbps. All PROFIBUS-DP slave services are supported. The software for the fieldbus controller is PNO certified. voltage and LON connection Cabling and bus termination voltage and LON connection Pin assignment of the panel-mounting connector Pin No. Function 1 positive supply voltage 2 ground M/5 shield 3 LON 4 LON PROFIBUS-DP PROFIBUS-DP connector Type 704041/0-64-24 Technical data Order details (1) (2) 704041/0-64 - 24 (1) Outputs..... Outputs PROFIBUS-DP interface 64 (2)..... Type 18 32V DC 24 Neuron chip EEPROM Transceiver Configuration and data exchange Material Dimensions W x H x D 3150 / 10MHz Flash-EEPROM AT29C512 18 32V DC (unstabilised) FTT10A entirely via ABS 80 x 172 x 43mm