M-1. Pilot Lights and Control Stations: Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.

Similar documents
Push Button. Rocker Arm

EFD/EFDB and EDS Series Factory Sealed Control Stations Explosionproof, Dust-Ignitionproof

EFD/EFDB and EDS Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof

Contender Series Factory Sealed Control Stations and Pilot Lights Explosionproof, Dust-Ignitionproof Furnished with Internal Ground Screw.

Intraground N1 Series Control Stations Nonmetallic 10 Amp, 600 Vac Max. for Heavy Duty Use.

ECS Selector Switch Control Stations Explosionproof, Dust-Ignitionproof, Factory Sealed and Non-Factory Sealed

ECS Control Stations V CSA Certification Only. Explosionproof, Dust-Ignitionproof, Factory Sealed and Non-Factory Sealed

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

EDS Factory Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof UNILETS for Use with Threaded Metal Conduit.

Division 2 Contender Series Factory Sealed Control Stations

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

EDS / EFS Series Control Stations

Spring-loaded cover seats against neoprene gasket.

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

EDS / EFS Series Control Stations

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY IRON ALLOY

UniCode Series Factory Sealed Control Stations and Pilot Lights

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

EDS / EFS Series Control Stations

Hazardous Factory Sealed Control Devices

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

Receptacle housing and cover optional malleable iron on EFS-M Series. Spring-loaded cover seats against neoprene gasket.

Product Information. Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit. MD2SR Interlocked Switched Receptacle

Control Stations Hazardous and Non-Hazardous

Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

Motor Starters Hazardous and Non-Hazardous

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Optitrol Series Control Stations and Pilot Lights Factory Sealed, Explosionproof, Dust-Ignitionproof. Furnished with Internal Ground Screw.

Plugs and Receptacles: Hazardous Location

L-1. Receptacles and Plugs: Explosionproof For use with Threaded Metal Conduit.

Standard Finishes Receptacles: epoxy powder coat Cord connector housings and caps: epoxy powder coat

FACTORY SEALED CONTROLS - INTRODUCTION

FACTORY SEALED CONTROLS - INTRODUCTION

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Circuit Breakers Hazardous

EBMC Combination Line Starters and Enclosures

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Twist Lock - Explosion Proof - Dust Ignition Proof Receptacle Assembly

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

STAINLESS STEEL PANEL MOUNT

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

WP Plugs and DS Receptacles For FS and FD Cast Device Boxes

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

GHG43 Series Control Stations

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

Covers for Cast Iron or Aluminum Device Boxes

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

EPOXY POWDER COATED COPPER FREE ALUMINUM

ALPF Factory Sealed Lighting - APPF Power Distribution Panelboards Explosionproof, Dust-Ignitionproof, Watertight

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

Condulet Cast Device Boxes and Covers Application and Selection

BUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight

Junction Boxes Hazardous and Non-Hazardous

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

Applications. Standard Materials. Certifications and Compliances

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Lighting Panelboards EPLU and D2LU Series IF Installation & Maintenance Information APPLICATION

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

Standard Materials Bodies and covers: copper-free aluminum.

Applications. Standard Materials

LIGHTING: EXPLOSIONPROOF FLOODLIGHT. Applications. Options

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

CIRCUIT BREAKERS. Explosionproof Circuit Breaker Enclosures EXPLOSIONPROOF MOTOR CONTROL EXPLOSIONPRROOF MOTOR CONTROL BREAKERS ENCLOSURES

Non-illuminated Push Buttons

HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF. Applications. Options

Hazardous Duty Applications

NMC Combination Line Starters and Enclosures

Industrial Control & Circuit Breakers

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box

Enclosures. Section E

O-3. Compliances UL Classified UL 508, 698, 1203 NEMA 4, 4X, 7CD, 9EFG For CSA approvals, please consult factory.

Condulet Conduit Bodies and Outlet Boxes Hazardous

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Transcription:

Pilot Lights and Control Stations: Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal Conduit. -1 EFDCB150J1U2 Combination Pilot Light and Push Buttons EFDCB175J2 Pilot Lights Intraground Push Button Intraground Combination Push Buttons and Pilot Light EFDL75J1DU2 Pilot Light and Dust Cap Push Buttons Intraground Pilot Light Intraground Combination Pilot Light and Selector Switch ED2SC175U2 Div. 2 Contender EDS150-RU2 Rocker Arm Push Buttons EFDB150-102 Selector Switch Intraground Selector Switch UCSC275U2 UniCode Intraground Receptacle Page Description 2-6 Control Station Catalog Numbering Guides 7-25 EFDB/EFD and EDS Factory Sealed Control Stations 7-8 Features 9 EFD/EFDB Push Buttons 10 EFD/EFDB Push Button/Pilot Light Combinations 11 EDS Rocker Arm Push Buttons and Parts 12 EFDB Dust Cap Push Buttons, Combinations and Parts 13 EFD/EFDB Pilot Lights 14-15 EFDB Selector Switches, Photocontrols 16 EFD/EFDB Push Button Accessories and Parts 17-18 EFD/EFDB Pilot Light Accessories and Parts 19 Nameplate ounting Bracket for Control Stations 20 EFDB Cover Assemblies and Covers Only 21 ESK/EFK Covers for Pilot Lights, Push Buttons, or Selector Switches for EFD Bodies 22 EFDB ounting Bodies for EFD and EDS Control Stations 22-23 EFDB Cast Device Boxes and Blank Bodies for Brazed Threaded Hubs 24,25 EFDB and EDS Dimensions 26-38 Contender Series Factory Sealed Control Stations and Pilot Lights 26-27 Features 28 Factory Sealed Push Button Stations 29 Factory Sealed Pilot Light Stations/ Combination Push Button and Pilot Light Stations 30 Factory Sealed Selector Switches 31 Push Button Stations/Push Button Stations with Rocker Arm Handles, Non-Factory Sealed 32-34 Push Buttons, Pilot Lights and Accessories 35 Covers with Pilot Lights or Push Buttons 39-47 Div. 2 Contender Series 48-59 Intraground N1 and N2 Series Non-etallic Control Stations 48-50 Features 51 Push Button and Push Buttons/Pilot Lights 52 Selector Switches/Pilot Lights 53 Selector Switches, Accessories and Parts 54 Covers and ounting Bodies 55-57 Push Button/Pilot Light Accessories and Parts 58 Receptacle and Fire Alarm Station 59 Dimensions 60-70 UniCode Series Factory Sealed Control Stations and Pilot Lights 71 AEPGI Series Explosionproof Ground Indicator PAGE 1

-2 Catalog Numbering Guide for EFDB/EFD, N1/N2, and Contender Control Stations Catalog Numbering Guide for EFD/EFDB Control Stations EFDC T 10 J1U2 JGBG SNPTESTQ U2 SR SNPRUNQ BACKBOX/HUB ARRANGEENT: EFD - Dead-End EFDC - Feed-Thru EFK - Cover Only BOX TYPE: Blank - 2 Gang B - Single Gang or Cover Only L - 3-Device T - Tandem HUB SIZE: 50-1/2 75-3/4 10-1 # OF GANGS: 1 - Single Gang 2 - Two Gang Blank DEVICE FOR FIRST GANG - SEE TABLE, PAGES -3 - Tandem, Cover Only or 3-Device Refer to pages -7 through -25 for complete details. Catalog Numbering Guide for N1/N2 Control Stations OPTIONS FOR FIRST GANG - SEE TABLE PAGES -3,-4 SPECIAL NAEPLATE FOR FIRST GANG - SEE TABLE PAGE -4 DEVICE FOR SECOND GANG - SEE TABLE, PAGES -3 OPTIONS FOR SECOND GANG - SEE TABLE, PAGES -3,-4 SPECIAL NAEPLATE FOR SECOND GANG - SEE TABLE, PAGE -4 N2D C 75 102 SRC SLNPFORNQ SERIES: N1D - Cover and Box N2D - Cover and Box N1K - Cover Only N2K - Cover Only HUB ARRANGEENT: Blank - Dead-End or Cover Only C - Feed-Thru HUB SIZE: 75-3/4 Blank - Cover Only DEVICE - SEE TABLE, PAGES -3 OPTIONS - SEE TABLE, PAGES -3,-4 SPECIAL NAEPLATE - SEE TABLE, PAGE -4 Refer to pages -49 through -60 for complete details. Catalog Numbering Guide for Contender Control Stations EDS C 2 1 524 J3 LNPUPQ 1274 S634 SLNPJORQ SERIES C Blank - Feed Thru - Dead End or Cover Only HUB SIZE: 1-1/2 2-3/4 3-1 BOX TYPE: 2 - Two Gang Blank - 1 Gang T - Tandem L - Three Device K - Cover Only DEVICE FOR FIRST GANG - SEE TABLE, PAGES -3 OPTIONS FOR FIRST GANG - SEE TABLE PAGES -3,-4 SPECIAL NAEPLATE FOR FIRST GANG- SEE TABLE, PAGE -4 DEVICE FOR SECOND GANG - SEE TABLE, PAGES -3 SPECIAL NAEPLATE FOR SECOND GANG - SEE TABLE, PAGE -4 OPTIONS FOR SECOND GANG - SEE TABLE, PAGES -3,-4 Refer to pages -26 through -38 for complete details. PAGE 2

Catalog Numbering Guide Descriptions for EFDB/EFD, N1/N2, and Contender Control Stations. -3 DEVICE DESCRIPTION EFD & N1 & N2 Suffix Contender Suffix Available in 1-G, 2-G* Tandem Available in Three Device One Pilot Light (Red Standard) J1 524 Y Two Pilot Lights J2 561 Y One Pilot Light & One omentary P.B. J1U1 473 Y One Pilot Light & Two omentary P.B. s J1U2 234 Y Y One Pilot Light & One aintained P.B. J1U1 701 Y One Pilot Light & One Dust-Cap P.B. J1DU1 702 Y One Pilot Light & One 12 Selector Switch * J112 703 Y One Pilot Light & One 35 Selector Switch * J135 704 Y One Pilot Light & One 102 Selector Switch * J1102 705 Y One Pilot Light & One 345 Selector Switch * J1345 706 Y One onetary P.B. U1 84 Y Two onetary P.B. s U2 90 Y Two Side-By-Side omentary P.B. s U2DBL 195 Y Three onetary P.B. s U3 707 Y Y One omentary P.B. & One aintained P.B. U1U1 708 Y One omentary P.B. & One Dust-Cap P.B. U1DU1 709 Y One omentary P.B. & One 12 Selector Switch * U112 710 Y One omentary P.B. & One 35 Selector Switch * U135 711 Y One omentary P.B. & One 102 Selector Switch * U1102 712 Y One omentary P.B. & One 345 Selector Switch * U1345 713 Y One aintained P.B. (ushroom Head - Red) U1 714 Y Two aintained P.B. U2 715 Y One aintained & One Dust-Cap P.B. U1DU1 716 Y One aintained P.B. & One 12-Selector Switch * U112 717 Y One aintained P.B. & One 35-Selector Switch * U135 718 Y One aintained P.B. & One 102-Selector Switch * U1102 719 Y One aintained P.B. & One 345 Selector Switch * U1345 720 Y One Dust Cap P.B. DU1 721 Y Two Dust Cap P.B. s DU2 722 Y One Dust Cap & One 12 Selector Switch * DU112 723 Y One Dust Cap & One 35 Selector Switch * DU135 724 Y One Dust Cap & One 102 Selector Switch * DU1102 725 Y One Dust Cap & One 345 Selector Switch * DU1345 726 Y One 12-Selector Switch * 12 271 Y One 35-Selector Switch * 35 272 Y One 102-Selector Switch * 102 273 Y One 345-Selector Switch * 345 274 Y 120VAC Photocell PC120 727 Y 277VAC Photocell PC277 728 Y Three Dust Cap P.B. s DU3 729 Y One omentary and Two aintained P.B. s U1U2 730 Y Two omentary and One aintained P.B. s U2U1 731 Y Y Three aintained P.B. s U3 732 Y Three Pilot Lights J3 476 Y Two Pilot Lights and One omentary P.B. J2U1 733 Y One Pilot Light and Two Dust Cap P.B. s J1DU2 734 Y Two Pilot Lights and One Dust Cap P.B. J2DU1 735 Y One Pilot Light and Two aintained P.B. s J1U2 736 Y Two Pilor Lights and One aintained P.B. J2U1 737 Y Effective September, 2008 Copyright 2008 PAGE 3

-4 Catalog Numbering Guide Descriptions for EFDB/EFD, N1/N2, and Contender Control Stations. Options Description EFD & N1 & Contender N2 Suffix Suffix omentary P.B. Securing Rod SR S153 Selector Switch Lockout LD S349 Spring Return From Right Selector Switch (3 Positions Only) SRC S634 Spring Return From Left Selector Switch (3 Positions Only) SLC S635 Alternate Contacts Selector Switch ALT S636 Change One Red Lens to Green Lens JGBG J3 Change One Red Lens to Opal Lens JGBO J8 Change One Red Lens to Amber Lens JGBA J6 Change One Red Lens to Blue Lens JGBB J11 Change One Red Lens to Clear Lens JGBC J10 Add 220 / 120 V Transformer (J1 Device Only) TR2 S801 Add 220 / 120 V Transformer (J1 Device Only) TR3 S802 Add 220 / 120 V Transformer (J1 Device Only) TR4 S803 Add 220 / 120 V Transformer (J1 Device Only) TR5 S804 Change One Red Pilot to Red LED LEDR LED1 Change One Red Lens to Green LED LEDG LED3 Change One Red Lens to Amber LED LEDA LED6 Add Red ushroom Head to omentary P.B. NRBRE S805 Add Black ushroom Head to omentary P.B. NRBBL S806 Add Green ushroom Head to omentary P.B. NRBGR S807 Locking Guard for aintained P.B. SPBLG S808 Nameplates * ushroom Head Pushbuttons (aintained and omentary) START NPSTQ STOP NPSPQ EERGENCY STOP NPESTPQ BLANK NPBQ Pilot Light BLANK LNPBQ FORWARD LNPFWDQ JOG LNPJOGQ RUN LNPRUNQ STOP LNPSPQ START LNPSTQ DOWN LNPDOWNQ FAST LNPFASTQ SLOW LNPSLOWQ RAISE LNPRAISEQ LOWER LNPLOWERQ RESET LNPRESETQ OFF LNPOFFQ ON LNPONQ REVERSE LNPREVQ CLOSE LNPCLOSEQ OPEN LNPOPENQ UP LNPUPQ Pilot Light (continued) TEST LNPTESTQ LOW LNPLOWQ HIGH LNPHIGHQ Two-Position Selection Switch Nameplates FORWARD-REVERSE SLNPFRQ HAND-AUTO** SLNPHAQ ON-OFF SLNPOO START-STOP SLNPSS BLANK SLNPBQ UP-DOWN SLNPUDQ RUN-JOG SLNPRJQ AUTO-HAND SLNPAHQ OFF-REOTE SLNPORQ Three-Position Selection Switch Nameplates FORWARD-OFF-REVERSE SLNPFORQ HAND-OFF-AUTO** SLNPHOAQ RUN-OFF-JOG SLNPROJQ BLANK SLNPB3 REVERSE-OFF-FORWARD SLNPROFQ AUTO-OFF-HAND SLNPAOHQ HAND-OFF-REOTE SLNPHORQ 1-OFF-2 SLNP102Q JOG-OFF-RUN SLNPJORQ STOP-RUN-START SLNPSRSQ LOCAL-OFF-REOTE SLNPLORQ ementary Pushbuttons For Rectangular Weatherboot Style Only (Not for round weatherboot style) BLANK** SNPBQ FORWARD SNPFWDQ JOG SNPJOGQ RUN SNPRUNQ STOP** SNPSPQ START** SNPSTQ DOWN SNPDOWNQ FAST SNPFASTQ SLOW SNPSLOWQ RAISE SNPRAISEQ LOWER SNPLOWERQ RESET SNPRESETQ OFF SNPOFFQ ON SNPONQ REVERSE SNPREVQ OPEN CLOSE SNPCLOSEQ UP SNPOPENQ TEST SNPTESTQ LOW SNPLOWQ HIGH SNPHIGHQ * No custom nameplates available **Included as standard (no need to use suffix) Standard on maintained 2 and 3 position selector switches Effective September, 2008 Copyright 2008 PAGE 4

Catalog Numbering Guide for Div. 2 Contender and UniCode Control Stations -5 Catalog Numbering Guide for Div. 2 Contender Control Stations ED2SC 75 U1 NRBRE UCLPB -- -- -- CONTENDER SERIES: ED2S1 - Dead-End Single Gang ED2SC1 - Feed-Thru Single Gang ED2S2 - Dead End Two Gang ED2SC2 - Feed Thru Two Gang ED2ST2 - Dead End Tandem ED2SCT2 - Feed Thru Tandem ED2SK - Cover only HUB SIZE: 50-1/2 75-3/4 10-1 DEVICE IN FIRST POSITION. SEE LISTINGS ON PAGE -6 OPTIONS FOR DEVICE IN FIRST POSITION. SEE LISTINGS ON PAGE -6 NAEPLATE FOR DEVICE IN FIRST POSITION. SEE LISTINGS ON PAGE -6 DEVICE/OPTIONS/ NAEPLATE FOR SECOND POSITION. SEE LISTINGS ON PAGE -6 DEVICE/OPTIONS/ NAEPLATE FOR THIRD POSITION. SEE LISTINGS ON PAGE -6 DEVICE/OPTIONS/ NAEPLATE FOR FOURTH POSITION. SEE LISTINGS ON PAGE -6 Refer to pages -39 through -47 for complete details. Catalog Numbering Guide for UniCode Control Stations UCSC 1 75 U1 NRBRE UCLPB -- -- -- UNICODE SERIES: UCS - Dead-End UCSC - Feed-Thru UCSK - Cover Only NO. OF DEVICES 1-1 Device 2-2 Devices 3-3 Devices 4-4 Devices DEVICE IN TOP POSITION. SEE LISTINGS ON PAGE -6 HUB SIZE: 50-1/2 75-3/4 10-1 50U - 1/2 Union 75U - 3/4 Union 10U - 1 Union OPTIONS FOR DEVICE IN TOP POSITION. SEE LISTINGS ON PAGE -6 NAEPLATE FOR DEVICE IN TOP POSITION. SEE LISTINGS ON PAGE -6 DEVICE/OPTIONS/ NAEPLATE FOR SECOND POSITION. SEE LISTINGS ON PAGE -6 DEVICE/OP- TIONS/ NAEPLATE FOR THIRD POSITION. SEE LISTINGS ON PAGE -6 DEVICE/OPTIONS/ NAEPLATE FOR FOURTH POSITION. SEE LISTINGS ON PAGE -6 Refer to pages -62 through -72 for complete details. PAGE 5

-6 DEVICE DESCRIPTION Catalog Numbering Guide Descriptions for UniCode and Div. 2 Contender Control Stations. DEVICE CODE omentary Push button - 1 NO/NC U1 omentary Push button - 2 NO/NC UD1 aintained Push button - 1 NO/NC U1 aintained Push button - 2 NO/NC UD1 Pilot Light J1 2-POS 2-CKT Selector Switch 12 3-POS 2-CKT Selector Switch 102 2-POS 4-CKT Selector Switch 35 3-POS 4-CKT Selector Switch 345 (Labyrinth switch only) Close-up Plug PLG Blank Cover (Div. 2 Contender Only) B OPTIONS DESCRIPTION Amber Pilot Light Green Pilot Light Blue Pilot Light DC Rating for Pilot Light Red ushroom Head - omentary Push button Green ushroom Head - omentary Push button Black ushroom Head - omentary Push button Black ushroom Head - aintained Push button Green ushroom Head - aintained Push button Spring Return From Right - Selector Switch Spring Return From Left - Selector Switch Spring Return From Left and Right Alternate Contacts - Selector Switch Red omentary Pushbutton Green omentary Pushbutton ACCESSORIES DESCRIPTION Stainless Steel ounting Feet (UniCode Only) Hermetic Sealed Switch (Universal) (UniCode Only) Hermetic Sealed Switch (NO or NC) (UniCode Only) OPTIONS CODE JGBA JGBG JGBB DC NRBRE NRBGR NRBBL NRBBL NRBGR SRC SLC SRL ALT PBRE PBGR ACCESSORY CODE SSTG HSW HSWNO, HSWNC Nameplate Options For UniCode and Div. 2 Contender * TWO POSITION SELECTOR SWITCH NAEPLATES FORWARD-REVERSE HAND-AUTO ON-OFF STRT-STOP BLANK UCLP-FR UCLP-HA UCLP-OO UCLP-SS UCLP-B THREE POSITION SELECTOR SWITCH NAEPLATES FORWARD-OFF-REVERSE HAND-OFF-AUTO RUN-OFF-JOG BLANK PILOT LIGHT NAEPLATES BLANK RUN ON OFF *Special Nameplates available. Consult factory. UCLP-FOR UCLP-HOA UCLP-ROJ UCLP-B UCPLP-B UCPLP-RUN UCPLP-ON UCPLP-OFF PUSH BUTTON (STANDARD, USHROO HEAD AND USHROO HEAD AINTAINED) NAEPLATES BLANK OFF ON FORWARD REVERSE JOG RUN START STOP UP DOWN FAST SLOW RAISE LOWER OPEN CLOSE LOW HIGH TEST EERGENCY STOP RESET UCLP-B UCLP-OFF UCLP-ON UCLP-FWD UCLP-REV UCLP-JOG UCLP-RUN UCLP-ST UCLP-SP UCLP-UP UCLP-DOWN UCLP-FAST UCLP-SLOW UCLP-RAISE UCLP-LOWER UCLP-OPEN UCLP-CLOSE UCLP-LOW UCLP-HIGH UCLP-TEST UCLP-ESTP UCLP-RESET PAGE 6

Factory Sealed Control Stations and Pilot Lights: EFDB/EFD and EDS Series Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal Conduit. -7 Applications Push buttons and selector switches are used in conjunction with contactors or magnetic starters for remote control of motors. They provide circuit control and/or selection. Pilot lights provide visual assurance that an electrical function is being performed at a remote or local location. EFD/EFDB and EDS factory sealed control stations confine arcing of device within the enclosure, preventing ignition of ignitable atmospheres during control operation of motors and other equipment. Used in classified areas where flammable vapors, gases or highly combustible dusts are present. For installation in chemical and petrochemical plants, refineries, and other process industries. Features: EFD/EFDB Factory Sealed Push Buttons and Selector Switches Eliminate need for adding sealing fittings and compound at each conduit entrance. Heavy-duty, 10 ampere 600V rated. Dozens of possible combinations of push buttons, pilot lights and selector switches. Smooth, rounded integral bushing in each EFD/EFDB hub protects conductor insulation. Accurately tapped, tapered hubs for tight, rigid joints and ground continuity. Stainless steel push button shaft operates within stainless steel bushing assuring long, maintenance-free operation. Push button and selector switch contacts are silver cadmium oxide which are sealed in lower phenolic chamber isolated from corrosive elements. Assures positive contact and long, trouble-free operation. Enclosed stainless steel helper spring prevents accidental operation of push button in severe vibration installations. Push button models also available with Dust Cap for use in areas where excessive dust, moisture or corrosive conditions are encountered. Corrosion-resistant captive stainless steel hex-head cap screws hold EFKB covers to body. EDS Rocker Arm Push Button EFDB Pilot Light All EFD/EFDB front-operated push buttons are suppled with lockout type guards as standard. Hole in guard will accept locks with up to 1/4 hasp. Permits locking of push button to prevent unauthorized operation. Clearly marked terminals with brass screws assure quick, easy wiring. Features: EFD/EFDB Pilot Lights Factory sealed pilot lights supplied with red jewel/guard assembly and 120V, 6W type 6S6 lamp. EFDB Photocontrol EFD Combination Pilot Light and Push Buttons odels also available in combination with factory sealed push buttons and selector switches. Features: EFD/EFDB Selector Switches Factory sealed selector switches furnished with nylon cam-operated, heavy-duty push buttons for either two-position or three-position maintained contact operation. High thermal and arc resistance, high dielectric strength. PAGE 7

-8 Factory Sealed Control Stations and Pilot Lights: EFDB/EFD and EDS Series Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal Conduit. Features: EDS Push Buttons Factory sealed eliminates need for adding sealing fittings and compound at each conduit entrance. Heavy duty, 10 ampere 600V rated. Switch is enclosed in separate sealing chamber. Sealing chamber has smooth, double flanges that mate both to cover and mounting enclosure to provide flame-tight joints. Pigtail leads from push buttons are factory sealed in sealing well. Stainless steel hex-head screws attach sealing chamber to cover and mounting enclosure. Side rocker arm push button has lockout holes. EFD/EFDB back box supplied with internal ground screw. Standard aterials EFDB control stations: malleable iron body with aluminum cover. SPBB push putton: aluminum upper barrel and phenolic lower barrel with nylon plastic button (Dust Cap models have neoprene buttons). SPLN/SPLS pilot light: aluminum guard and body assembly; steel clamping ring; and tempered glass jewel. SSBA selector switch: aluminum operator mechanism, nylon cam, and sealed phenolic contact block. EDS control stations: malleable iron body and cover; aluminum sealing chamber; and nylon 6/6 operating handle. Standard Finishes EFD/EFDB control stations: body, triplecoat (1) zinc electroplate, (2) dichromate, and (3) epoxy powder coat. SPBB push button, SPLN/SPLS pilot light and SSBA selector switch: natural finish. EDS control stations: body and cover, triple-coat (1) zinc electroplate, (2) dichromate, and (3) epoxy powder coat sealing chamber, natural finish. Options Three position selector switches with modified operation. omentary contact right position, spring return to center, maintained contact left position. For description and switch diagram see page -15. Add suffix SRC. Three position selector switches with modified operation. omentary contact left position, spring return to center, maintained contact right position. Add suffix SLC. Alternate contacts add suffix ALT. EFD/EFDB selector switch Lockout locks two- or three-position handle in any position. Suffix LD. Push button front operated mushroom head (momentary contact): In red, add suffix NRBRE; In green, add suffix NRBGR; In black, add suffix NRBBL. EFD/EFDB pilot light jewel/guard assembly. Order by suffixes if color desired is other than red, as follows: Amber, JGBA; Blue, JGBB; Clear JGBC; Green, JGBG; Opal, JGBO. For colored LED jewel/guard assembly, order by suffixes: red LEDR; green LEDG; amber LEDA. EFD/EFDB pilot light transformers for single pilot light per gang. Order by suffix: Primary Lamp Voltage Voltage Suffix 220 120 TR-2 277 120 TR-3 440 120 TR-4 550 120 TR-5 EFD and EDS units may be supplied with brazed hubs as 3, 4, and 5 gang in a variety of hub configurations. See Ordering Information page for how to order these and other custom units by adding suffixes to mounting body catalog numbers. Securing Rod for EFD/EFDB Push Button Lockout Guard. Suffix SR. For complete list of options, see Catalog Numbering Guide on Pages -2 through -4. Compliances UL Standard 698. Class I, Div. 1 and 2; Class II, Div. 1 and 2. See listing pages for specific groups. Appleton malleable iron products conform to AST A47-77, Grade 32510, which has the following properties: tensile strength, 50,000 psi; yield, 32,000 psi; and elongation, 10%. Appleton aluminum products are produced from high strength copperfree (4/10 of 1% max.) alloy. EDS factory sealed rocker arm push button control station shows separate sealing chamber and device construction. Rocker arm has holes for lock. Securing Rod for EFD/ EFDB Push Button Lockout Guard available as an optional item as catalog number NBL-SR (single guard only) or add Suffix SR to push button catalog number. Lockout Guard, furnished as standard with the EFD/ EFDB push button, may also be padlocked. SPBB factory sealed push button used in EFD/EFDB Series standard type and unit with dust cap. SPBB Design Features PAGE 8

Class I, Div. 1 and 2 Groups B,C,D Class II, Div. 1 and 2 Groups E,F,G NEA 3,7CD,9EFG EFD/EFDB Factory Sealed Push Button Stations: Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal Conduit. 10 Ampere, 600V A.C. ax. for Heavy Duty Use. Furnished with Internal Ground Screw. -9 U.S. Pat. 3,699,276 Hub Size, Nameplate Catalog Number Patented Canada 1974 Inches Description arking Dead-End Feed-Thru Single Gang* omentary Contact 1/2 1 Circuit Specify EFDB150-U1 EFDCB150-U1 3/4 Universal EFDB175-U1 EFDCB175-U1 1 EFDB110-U1 EFDCB110-U1 1/2 2 Circuits Specify EFDB150-U2 EFDCB150-U2 3/4 Universal EFDB175-U2 EFDCB175-U2 1 EFDB110-U2 EFDCB110-U2 aintained Contact 1/2 1 Circuit EFDB150-U1 EFDCB150-U1 3/4 Universal EFDB175-U1 EFDCB175-U1 1 EFDB110-U1 EFDCB110-U1 Two Gang* omentary Contact 1/2 2 Circuits Specify EFD250-U1 EFDC250-U1 3/4 Universal EFD275-U1 EFDC275-U1 1 EFD210-U1 EFDC210-U1 1/2 4 Circuits Specify EFD250-U2 EFDC250-U2 3/4 Universal EFD275-U2 EFDC275-U2 1 EFD210-U2 EFDC210-U2 Three Device omentary Contact 1/2 3 Circuits Specify EFDL50-U3 EFDCL50-U3 3/4 Universal EFDL75-U3 EFDCL75-U3 1 EFDL10-U3 EFDCL10-U3 * alleable iron body and aluminum cover. For aluminum body, add suffix A. Aluminum body, not available. Shaded area indicates items suitable for Class I, Div. 1 and 2, Groups B, C and D; Class II, Groups E, F and G and. For Class I, Group B, external seals must be installed at each conduit entrance. See page 16 for push button accessories and parts. Dimensions on pages 24 and 25. PAGE 9

-10 Class I, Div. 1 and 2 Groups B,C,D Class II, Div. 1 and 2 Groups E,F,G NEA 3,7CD,9EFG EFD/EFDB Factory Sealed Combination Push Button and Pilot Light Stations: Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal Conduit. 10 Ampere, 600V A.C. ax. for Heavy Duty Use. omentary Contact. Furnished with Internal Ground Screw. U.S. Pat. 3,699,276 Hub Size, Nameplate Catalog Number Patented Canada 1974 Inches Description arking Dead-End Feed-Thru Single Gang* 1/2 1 Circuit Specify EFDB150-J1U1 EFDCB150-J1U1 3/4 Universal EFDB175-J1U1 EFDCB175-J1U1 1 and 1 Pilot EFDB110-J1U1 EFDCB110-J1U1 Light 1 Circuit 1 Pilot Light 2 Circuit 1 Pilot Light 1/2 2 Circuits Specify EFDB150-J1U2 EFDCB150-J1U2 3/4 Universal EFDB175-J1U2 EFDCB175-J1U2 1 and 1 Pilot EFDB110-J1U2 EFDCB110-J1U2 Light Two Gang* 1/2 2 Circuits Specify EFD250-J1U2 EFDC250-J1U2 3/4 Universal EFD275-J1U2 EFDC275-J1U2 1 and 1 Pilot EFD210-J1U2 EFDC210-J1U2 Light 1 Pilot Light 2 Circuit 2 Pilot Lights 2 Circuit 1/2 2 Circuits Specify EFD250-J2U2 EFDC250-J2U2 3/4 Universal EFD275-J2U2 EFDC275-J2U2 1 and 2 Pilot EFD210-J2U2 EFDC210-J2U2 Lights Three Device 1/2 2 Circuits Specify EFDL50-J1U2 EFDCL50-J1U2 3/4 Universal EFDL75-J1U2 EFDCL75-J1U2 1 and 1 Pilot EFDL10-J1U2 EFDCL10-J1U2 Light 2 Circuit, 1 Pilot Light 1 Circuit, 2 Pilot Lights 1/2 1 Circuit Specify EFDL50-J2U1 EFDCL50-J2U1 3/4 Universal EFDL75-J2U1 EFDCL75-J2U1 1 and 2 Pilot EFDL10-J2U1 EFDCL10-J2U1 Lights Two Gang Tandem 1/2 2 Circuits Specify EFDT50-J1U2 EFDCT50-J1U2 3/4 Universal EFDT75-J1U2 EFDCT75-J1U2 1 and 1 Pilot EFDT10-J1U2 EFDCT10-J1U2 Light 2 Circuit, 2 Pilot Lights 2 Circuit, 1 Pilot Light 1/2 2 Circuits Specify EFDT50-J2U2 EFDCT50-J2U2 3/4 Universal EFDT75-J2U2 EFDCT75-J2U2 1 and 2 Pilot EFDT10-J2U2 EFDCT10-J2U2 Lights * alleable iron body and aluminum cover. For aluminum body, add suffix A. Aluminum body not available. For tandem bodies, external seals must be installed within 5 feet of each conduit entrance for Class I, Groups C and D. Pilot Lights furnished with 6W, 120V A.C. 6S6 lamp and red jewel Other colored jewels and LED s listed on page 17. See page 16 for push button accessories and parts. Shaded area indicates items suitable for Class I, Div. 1 and 2, Groups B, C and D; Class II, Groups E, F and G and. For Class I, Group B, external seals must be installed at each conduit entrance. Dimensions on pages 24 and 25. PAGE 10

Class I, Div. 1 and 2 Groups B,C,D Class II, Div. 1 and 2 Groups E,F,G NEA 3,7BCD,9EFG EDS Factory Sealed Push Button Stations with Rocker Arm Handle: Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal Conduit. 10 Ampere, 600V A.C. ax. for Heavy Duty Use. Furnished with Internal Ground Screw. -11 Hub Size, Nameplate Catalog Number Inches Description arking Dead-End Feed-Thru Single Gang alleable Iron Body and Cover* omentary Contact 1/2 1 Circuit Specify EDS150-RU1 EDSC150-RU1 3/4 Universal EDS175-RU1 EDSC175-RU1 1 EDS110-RU1 EDSC110-RU1 1/2 2 Circuits Specify EDSC150-RU2 3/4 Universal EDS175-RU2 EDSC175-RU2 1 EDS110-RU2 EDSC110-RU2 Two Gang alleable Iron Body and Cover* omentary Contact 1/2 2 Circuits Specify EDSC250-RU1 3/4 Universal EDS275-RU1 EDSC275-RU1 1 EDS210-RU1 EDSC210-RU1 1/2 4 Circuits Specify EDSC250-RU2 3/4 Universal EDS275-RU2 EDSC275-RU2 1 EDS210-RU2 EDSC210-RU2 Nameplate Cover and Chamber Description arking with Device omentary Contact 1 Circuit Universal Specify EFK-RU1-Q 2 Circuits Universal Specify EFK-RU2-Q Cover and Chamber with Device Shaded area indicates items suitable for Class I, Group B, in addition to Class I, Groups C and D; Class II, Groups E, F, and G; and. *For aluminum body, add suffix A. (not suitable for Class I, Group B). For dimensions, see page 24. PAGE 11

-12 Class I, Div. 1 and 2 Groups B,C,D Class II, Div. 1 and 2 Groups E,F,G NEA 3,7CD,9EFG EFD/EFDB Factory Sealed Dust Cap Push Button Stations: Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal Conduit. 10 Ampere, 600V A.C. ax. for Heavy Duty Use. omentary Contact. Furnished with Internal Ground Screw. U.S. Pat. 3,699,276 Hub Size, Nameplate Catalog Number Patented Canada 1974 Inches Description arking Dead-End Feed-Thru Single Gang* 3/4 1 Circuit Specify EFDB175-DU1* EFDCB175-DU1* 1 Universal EFDB110-DU1* EFDCB110-DU1* 3/4 2 Circuits Specify EFDB175-DU2* EFDCB175-DU2* 1 Universal EFDB110-DU2* EFDCB110-DU2* Three Device 3/4 2 Circuits Specify EFDL75-J1DU2 EFDCL75-J1DU2 1 Universal EFDL10-J1DU2 EFDCL10-J1DU2 and 1 Pilot Light Nameplate Catalog Description arking Number Push Button and Replacement Cap Dust Cap Push Button STOP-START-BLANK SPBB-DU1-Q Replacement Dust Cap Only STOP-START-BLANK DC-Q Nameplate STOP-START-BLANK DU-NP-Q Has 1/2-14NPS thread size. Supplied with 1/2 to 3/4 enlarger. Covers Complete with Pilot Lights, Push Buttons Factory-Sealed 1 Circuit Specify EFKB-DU1 Universal 2 Circuits Specify EFKB-DU2 Universal 2 Circuits Specify EFKL-J1DU2 Universal and 1 Pilot Light * alleable iron body and aluminum cover. For aluminum body, add suffix A. Aluminum body not available. For use with three device mounting bodies. Shaded area indicates items suitable for Class I, Div. 1 and 2, Groups B, C and D; Class II, Groups E, F and G and. For Class I, Group B, external seals must be installed at each conduit entrance. Dimensions on pages 24 and 25. PAGE 12

Class I, Div. 1 and 2 Groups B,C,D Class II, Div. 1 and 2 Groups E,F,G NEA 3,7CD,9EFG -13 EFD/EFDB Factory Sealed Pilot Light Stations: Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal Conduit. Pilot Light Furnished with 6W, 120V A.C. 6S6 Lamp and Red Jewel. Furnished with Internal Ground Screw. Hub Size, Catalog Number Inches Description Dead-End Feed-Thru Single Gang* 1/2 One EFDB150-J1 EFDCB150-J1 3/4 Pilot Light EFDB175-J1 EFDCB175-J1 1 EFDB110-J1 EFDCB110-J1 1/2 Two EFDB150-J2 EFDCB150-J2 3/4 Pilot Lights EFDB175-J2 EFDCB175-J2 1 EFDB110-J2 EFDCB110-J2 Two Gang* 1/2 Two EFD250-J1 EFDC250-J1 3/4 Pilot Lights EFD275-J1 EFDC275-J1 1 EFD210-J1 EFDC210-J1 1/2 Four EFD250-J2 EFDC250-J2 3/4 Pilot Lights EFD275-J2 EFDC275-J2 1 EFD210-J2 EFDC210-J2 Three Device 1/2 Three EFDL50-J3 EFDCL50-J3 3/4 Pilot Lights EFDL75-J3 EFDCL75-J3 1 EFDL10-J3 EFDCL10-J3 Two Gang Tandem 1/2 Two EFDT50-J1 EFDCT50-J1 3/4 Pilot Lights EFDT75-J1 EFDCT75-J1 1 EFDT10-J1 EFDCT10-J1 1/2 Four EFDT50-J2 EFDCT50-J2 3/4 Pilot Lights EFDT75-J2 EFDCT75-J2 1 EFDT10-J2 EFDCT10-J2 Other colored jewels, LED s, and pilot light accessories and parts are listed on page 17. Dimensions on pages 24 and 25. * alleable iron body and aluminum cover. For aluminum body, add suffix A. Aluminum body not available. For tandem bodies, external seals must be installed within 5 feet of each conduit entrance for Class I, Groups C and D. Shaded area indicates items suitable for Class I, Groups B, C and D; Class II, Groups E, F, and G; and. For Class I, Group B external seals must be installed at each conduit entrance. PAGE 13

-14 Class I, Div. 1 and 2 Groups B,C,D Class II, Div. 1 and 2 Groups E,F,G NEA 3,7CD,9EFG EFDB Factory Sealed Selector Switches and Photocontrols: Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal Conduit. 10 Ampere, 600V A.C. ax. for Heavy Duty Use. Furnished with Internal Ground Screw. Hub Size, Diagram Catalog Number Selector Switches Inches Description Left Center Right Dead-End Feed-Thru Single Gang* aintained Contact 1/2 2 Position, None EFDB150-12 EFDCB150-12 3/4 2 Circuit EFDB175-12 EFDCB175-12 1 EFDB110-12 EFDCB110-12 1/2 2 Position, None EFDB150-35 EFDCB150-35 3/4 4 Circuits EFDB175-35 EFDCB175-35 1 EFDB110-35 EFDCB110-35 Three position units can be supplied for momentary contact right position, spring return to center, maintained contact left position. Add suffix SRC. 1/2 3 Position, EFDB150-102 EFDCB150-102 3/4 2 Circuit EFDB175-102 EFDCB175-102 1 EFDB110-102 EFDCB110-102 1/2 3 Position, EFDB150-345 EFDCB150-345 3/4 4 Circuits EFDB175-345 EFDCB175-345 1 Note: Standard legend plate reads HAND OFF AUTO EFDB110-345 EFDCB110-345 Two Position Nameplates Three Position Nameplates Two Position Nameplate Three Position Nameplate Forward Reverse SLNP-FRQ Forward Off Reverse SLNP-FORQ Hand Auto SLNP-HAQ Hand Off Auto SLNP-HOAQ On Off SLNP-OO Run Off Jog SLNP-ROJQ Start Stop SLNP-SS Blank SLNP-B3 Blank SLNP-BQ Reverse Off Forward SLNP-ROFQ Up Down SLNP-UDQ Auto Off Hand SLNP-AOHQ Run Job SLNP-RJQ Hand Off Remote SLNP-HORQ Auto Hand SLNP-AHQ 1 Off 2 SLNP-102Q Off Remote SLNP-ORQ Jog Off Run SLNP-JORQ Stop Run Start SLNP-SRSQ Local Off Remote SLNP-LORQ Selector Switch Locking Devices Permit locking in any position. Two or Three Positions SBL-3-Q Hub Size, ax. ax. Catalog Number Photocontrols Inches Voltage Current VA Dead-End Feed-Thru 1/2 120 8.3A 1000 EFDB150PC120 EFDCB150PC120 3/4 120 8.3A 1000 EFDB175PC120 EFDCB175PC120 1 120 8.3A 1000 EFDB110PC120 EFDCB110PC120 1/2 208-277 3.5A 1000 EFDB150PC277 EFDCB150PC277 3/4 208-277 3.5A 1000 EFDB175PC277 EFDCB175PC277 1 208-277 3.5A 1000 EFDB110PC277 EFDCB110PC277 * alleable iron body and aluminum cover. For aluminum body, add suffix A. (Suitable for Class I, Div. 1 and 2, Group B single gang only). Supplied as standard with maintained contact selector switches. Specify catalog number from nameplate listings if other than standard nameplate is desired. Shaded area indicates items suitable for Class I, Div. 1 and 2, Groups B, C and D; Class II, Groups E, F and G and. For Class I, Group B, external seals must be installed at each conduit entrance. PAGE 14

Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups E,F,G NEA 3,7CD,9EFG EFDB Factory Sealed Selector Switches and Cover Assemblies: Explosionproof, Dust-Ignitionproof 10 Ampere, 600V A.C. ax. for Heavy Duty Use. -15 EFDB Selector Switch Operator/Switch Assembly (aintained Contact) Thread Switch Switch Size Diagram Assembly Assembly (In., NPS) Description Left Center Right Only with Cover 1/2 2 Position, None SSBA1-2Q EFKB-12 2 Circuit 1/2 2 Position, None SSBA2-2Q EFKB-35 4 Circuits 1/2 3 Position, SSBA1-3Q EFKB-102 2 Circuit 1/2 3 Position, SSBA2-3Q EFKB-345 4 Circuits EFDB Selector Switch Operator/Switch Assembly (odified Operations) Thread Switch Switch Size Diagram Assembly Assembly (In., NPS) Description Left Center Right Only with Cover 1/2 3 Position, SSBAS-1-3 EFKB-102-SRC 2 Circuit 1/2 3 Position, SSBAS-2-3 EFKB-345-SRC 4 Circuits omentary contact right position. Spring return to center. aintained contact left position. Note: Standard legend plate reads HAND OFF AUTO 1/2 3 Position, SSBASL-1-3 EFKB-102-SLC 2 Circuit 1/2 3 Position, SSBASL-2-3 EFKB-345-SLC 4 Circuits omentary contact left position. Spring return to center. aintained contact right position. Note: Standard legend plate reads AUTO OFF HAND 1/2 3 Position, SSBASRA-2-3 EFKB-637-SRC 4 Circuit omentary contact right position. Spring return to center. aintained contact left position. Note: Standard legend plate reads STOP RUN START PAGE 15

-16 Class I, Div. 1 and 2 Groups B*,C,D Class II, Div. 1 and 2 Groups E,F,G EFD/EFDB Push Buttons: Accessories and Parts Single Push Button omentary Contact Description Catalog Number Push Button, Factory Sealed - omentary Contact 10 Amp 600V A.C. Heavy Duty 1/2 thread size. Furnished with 1/2 to 3/4 enlarger, Weather Boot, Guard, Start, Stop and Blank Nameplates. Double Push Button omentary Contact aintained Contact Single Push Button, Universal Double Push Button, Universal SPBB-U1-Q SPBB-U2DBL Push Button (Red), Factory Sealed - aintained Contact 10 Amp 600V A.C. Heavy Duty 1/2 thread size. Furnished with 1/2 to 3/4 enlarger, Guard not furnished. Universal Rectangular Button with Weather Boot Furnished with Start, Stop and Blank Nameplates. SPB-U1-Q NBN-WB Nameplates for Rectangular Push Buttons Blank SNP-B-Q Off SNP-OFF-Q Forward SNP-FWD-Q On SNP-ON-Q Jog SNP-JOG-Q Reverse SNP-REV-Q Run SNP-RUN-Q Open SNP-OPEN-Q Stop SNP-SP-Q Close SNP-CLOSE-Q Start SNP-ST-Q Up SNP-UP-Q Down SNP-DOWN-Q Test SNP-TEST-Q Fast SNP-FAST-Q Low SNP-LOW-Q Slow SNP-SLOW-Q High SNP-HIGH-Q Raise SNP-RAISE-Q Lower SNP-LOWER-Q Reset SNP-RESET-Q Push Button Replacement Locking Guards-Glass Reinforced Polypropylene (Gasketed) Has hole for 1/4 hasp. aintained Switch Guard Single Guard Double Guard Single Guard (aintained Switch) Single Guard Double Guard Single Guard (No Lockout Holes) Double Guard (No Lockout Holes) SPB-LG NPB-LG1 NPB-LG2 NPB-LG1-LL NPB-LG2-LL Push Button Securing Rod with Chain-Stainless Steel (For use with Single Guard Only) NBL-SR ushroom Button with Weather Boot (Gasketed) For use with omentary Contact Black Green Red NRB-BL NRB-GR NRB-RE For use with aintained For use with omentary ushroom Button (For use with aintained Contact) Solid-colored non-metallic button. Red NRB-RE Nameplates For ushroom Head Push Button (omentary & aintained) Start Stop Emergency Stop Blank NPSTQ NPSPQ NPESTPQ NPBQ *Suitable for Class I, Group B when installed in an enclosure rated for Class I, Group B. PAGE 16

Class I, Div. 1 and 2 Groups B*,C,D Class II, Div. 1 and 2 Groups E,F,G EFD/EFDB Pilot Lights: Accessories and Parts -17 Description Catalog Number Pilot Light, Factory Sealed Incandescent Furnished with 6S6 120V incandescent lamp, jewel and guard. Has 18 long, type SFF-2 (150 C) pigtail leads. Body has 3/4 straight thread (NPS). Pilot Light With Red Jewel With Green Jewel With Amber Jewel With Blue Jewel With Clear Jewel With Opal Jewel SPLSREB SPLSGRB SPLSAB SPLSBLB SPLSCLB SPLSOPB Chamber Only Pilot Light, Factory Sealed LED Furnished with candelabra base 120V LED, jewel and guard. Has 18 long, type SFF-2 (150 C) pigtail leads. Body has 3/4 straight thread (NPS). With Red LED, Clear Jewel With Green LED, Clear Jewel With Amber LED, Clear Jewel SPLNSREB SPLNSGRB SPLNSAB Chamber Only (Same as above, less jewel, guard and lamp) SPLSSCB Pilot Light Jewel/Guard Assembly The below catalog numbers indicate an assembly of the Pilot Light Jewels and Guards. Jewels and Guards are not available as separate items. Amber Jewel/Guard Blue Jewel/Guard Clear Jewel/Guard Green Jewel/Guard Opal Jewel/Guard Red Jewel/Guard JGBNA JGBNB JGBNC JGBNG JGBNO JGBNR Transformer Add Suffix as listed below. Transformer clamps directly to pilot light barrel. Only one pilot light transformer assembly per one gang body. Primary Voltage Lamp Voltage Suffix 220 120 TR2 277 120 TR3 440 120 TR4 550 120 TR5 Clear Bulbs Furnished with candelabra base. 6W, 120V Type 6S6 LED Replacements Furnished with candelabra base. 120 VAC, 10 ma Red LED Green LED Amber LED *Suitable for Class I, Group B when installed in an enclosure rated for Class I, Group B. EPL-B6W EPLLEDR EPLLEDG EPLLEDA PAGE 17

-18 EFD/EFDB Series Pilot Lights: Accessories Description Nameplates for Pilot Light Blank Forward Jog Run Stop Start Down Fast Slow Raise Lower Reset Off On Reverse Close Open Up Test Low High Catalog Number LNPBQ LNPFWDQ LNPJOGQ LNPRUNQ LNPSPQ LNPSTQ LNPDOWNQ LNPFASTQ LNPSLOWQ LNPRAISEQ LNPLOWERQ LNPRESETQ LNPOFFQ LNPONQ LNPREVQ LNPCLOSEQ LNPOPENQ LNPUPQ LNPTESTQ LNPLOWQ LNPHIGHQ PAGE 18

NPBRKT Nameplate ounting Bracket For use with EFDB, EFS, Contender and N1/N2 Series Control Stations, Tumbler Switches and anual otor Starters. -19 Applications For mounting on EFDB, EFS, Contender and Intraground series control stations to make circuit description/ identification easy. Features Pre-drilled holes in bottom of bracket allow direct mounting to Appleton EFDB, EFS, Contender and intraground series control stations with existing cover bolts (Intraground series bracket is mounted using nameplate screws). Pre-drilled holes in middle of bracket allow mounting of customer s circuit identification nameplate; epoxy glue may also be used for mounting (phenolic nameplate not included). Nameplate mounting bracket is corrosion resistant stainless steel. Bracket eliminates costly field installation of drilling and tapping to accommodate circuit identification nameplate. Brackets fit side-by-side on 2, 3 and 4 gang boxes and 3 Device EFD Series. Description Catalog Number* Nameplate ounting Bracket for EFDB and EFS series NPBRKT-EFDB Nameplate ounting Bracket for Contender and 3 Device EFD Series NPBRKT-C0NT Nameplate ounting Bracket for N1/N2 series NPBRKT-N1N2 * To order bracket with either series control station or manual motor starter, add suffix NPBRKT to end of catalog number. Dimensions (In Inches): Note: ount bracket between cover screws and cover. Do not mount bracket between ground joint flame path between cover and back box. 1.00 2.00 Secure bracket under cover screws of box. Torque cover screws to 12ft - lbs. Catalog No. A B C D E NPBRKT-CONT 2.81 2.50 3.38 2.75.27 x.33 NPBRKT-EFDB 2.38 2.50 3.00 2.75.25 NPBRKT-N1N2 2.13 2.25 2.75 2.69.16 PAGE 19

-20 Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups E,F,G EFKB Covers with Pilot Lights, Push Buttons, or Photocontrol for EFD Bodies All Covers are Copper-Free Aluminum. Supplied with Four Captive Stainless Steel Bolts. Nameplate Catalog Description arking Number Cover complete with Push Button Factory Sealed, omentary Contact For use on standard EFD bodies U1 U2 1 Circuit Universal Specify* EFKB-U1 2 Circuit Universal Specify* EFKB-U2 Cover complete with Push Button Factory Sealed, aintained Contact For use on standard EFDB bodies 1 Circuit Universal (Red) Specify EFKB-U1 Cover complete with Pilot Lights Factory Sealed, omentary Contact 6W120V, Type 6S6 Lamp. For use on standard EFD bodies J1U2 One pilot light (red jewel ) and two Specify* EFKB-J1U2 universal push buttons One pilot light (red jewel ) and one Specify* EFKB-J1U1 universal push button One pilot light (red jewel ) and one Specify* EFKB-J1DU1 universal push button dust cap J1 One pilot light (red jewel ) Specify EFKB-J1 Two pilot lights (red jewels ) Specify EFKB-J2 Photocontrol relay cover (120V) Photocontrol relay cover (208-277V) EFKB-PC120 EFKB-PC277 J2 * Start - Stop and Blank Nameplate Standard Other colored jewels listed on Page 17 PAGE 20

Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups E,F,G -21 ESK/EFK Covers for Pilot Lights, Push Buttons, or Selector Switches for EFD Bodies All Covers are Copper-Free Aluminum. Supplied with Four Captive Stainless Steel Bolts*. Description Covers Only for use on standard EFD bodies Supplied with 4 cover bolts and blank cover nameplate. Catalog Number Push Button or Pilot Light Covers 3/4 tapped openings One opening: one push button or one pilot light Two openings: two push buttons, two pilot lights, or one of each Three openings: three device (EFDL) three push buttons or three pilot lights, or combination of push button(s) and pilot light(s) ESKB-1PBQ ESKB-2PBQ EFKL-3HQ* Push Button or Selector Switch Cover 1/2 tapped openings. 2SPQ Two openings: selector switch or two push buttons Push Button, Pilot Light or Selector Switch Covers 3/4 top and 1/2 bottom tapped openings. ESKB-2SPQ One top and two bottom openings: one pilot light, two push buttons; one pilot light, one selector switch. Blank * Cat. No. EFKL-3HQ supplied with 6 stainless steel non-captive bolts. ESKB-3JPBQ ESKB-BQ PAGE 21

-2-22 Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups E,F,G NEA 7CD,9EFG ounting Bodies for EFD and EDS Control Stations Furnished with Internal Ground Screw. Hub Size, Dead-End Catalog Numbers Feed-Thru Catalog Numbers Inches alleable Iron Aluminum alleable Iron Aluminum Single Gang, Two Gang, Tandem, and Three Device Bodies Single Gang 1/2 EFD150-NL-Q EFD150A-NL-Q EFDC150-NL-Q EFDC150A-NL-Q 3/4 EFD175-NL-Q EFD175A-NL-Q EFDC175-NL-Q EFDC175A-NL-Q 1 EFD110-NL-Q EFD110A-NL-Q EFDC110-NL-Q EFDC110A-NL-Q Two-Gang 1/2 EFD250-NL-Q EFD250A-NL-Q EFDC250-NL-Q EFDC250A-NL-Q 3/4 EFD275-NL-Q EFD275A-NL-Q EFDC275-NL-Q EFDC275A-NL-Q 1 EFD210-NL-Q EFD210A-NL-Q EFDC210-NL-Q EFDC210A-NL-Q Tandem 1/2 EFDT50-NL-Q EFDCT50-NL-Q 3/4 EFDT75-NL-Q EFDCT75-NL-Q 1 EFDT10-NL-Q EFDCT10-NL-Q Three Device For use with EFKL Covers. 1/2 EFDL50-Q EFDCL50-Q 3/4 EFDL75-Q EFDCL75-Q 1 EFDL10-Q EFDCL10-Q Blank Bodies for Brazed Hubs Deep malleable iron Gang Cat. No. 1 Gang EFD-1-NL 2 Gang EFD-2-NL 3 Gang EFD-3-NL 4 Gang EFD-4-NL 5 Gang EFD-5-NL Construct complete catalog number per page -23. Hubs will be located in center of walls and evenly spaced unless otherwise specified. Where spacings are critical, submit sketch showing spacing requirements. Covers and Devices are listed on Pages -12,15,20, and 21. Accessories on Pages -16, 17, and 18. Dimensions on Pages -24 and 25. For tandem bodies, external seals must be installed within 5 feet of each conduit entrance for Class I, Groups C and D. PAGE 22

Ordering Information: EFD Cast Device Boxes; Blank Bodies for Brazed Threaded Hubs Single, Two, Three, Four and Five Gang Boxes. Brazed Threaded Hubs for Rigid Conduit, 1/2 thru 1 ; Brazed Union Hubs, 1/2 thru 1. -23 Determine catalog number as follows: (1) select EFD device box catalog number; (2) select Standard Hub Arrangement Diagram number; and (3) select symbols that represent hub sizes from Symbol Table. (Use 0 where no hub is required, and separate the various divisions of the complete catalog number by dashes.) Example The blank body device box selected is EFD3NL and the hub arrangement is diagram #8. Hub a is to be 3/4 BRAZED THREADED; hub b, 1 BRAZED THREADED; hub c, 3/4 BRAZED THREADED; hub d, no hub is required; and hub e, 1 BRAZED UNION. The complete catalog number will be: EFD 3NL 8 2320T Standard Hub Arrangement Diagrams Hub a is always TOP of box Two, Three, Four and Five Gang (Front View) Single Gang (Front View) Symbol Table Brazed Brazed Hub Threaded Union Size Hub Hub (Inches) Symbol Symbol Blank 0 0 1/2 1 1E 3/4 2 2E 1 3 3E If a Standard Hub Arrangement is not suitable for the application, or when hubs are to be more accurately spaced, submit sketch locating hubs (1) from centerlines of walls and (2) from outside back of box (or from mounting lug surface if lugs are supplied). All hubs will be located in centerlines of walls and evenly spaced unless otherwise specified. PAGE 23

-24 Dimensions: EFD/EFDB Push Buttons, EFDB Dust Cap Push Buttons; Pilot Light; EDS Rocker Arm Push Button EFD/EFDB Single and Two Gang Combination Pilot Light and Push Buttons 11/32 Dia. (2) tg. Holes EFD/EFDB Single Gang Dust Cap Push Button, Single Gang aintained Contact Push Button, and Photo Control EDS Single and Two Gang Rocker Arm Push Button Dimensions in Inches Dimensions in Centimeters Hub Size A B C A B C 1/2 and 3/4 5.38 6.13.78 13.7 15.6 2.0 1 5.50 6.31.94 14.0 16.0 2.4 PAGE 24

Dimensions: EFD Three Device and Two Gang Tandem -25 EFD Three Device Pilot Light and Push Buttons 1/2 and 3/4 Hub =.78 (2.0cm) 1 Hub =.94 (2.4cm) 9/32 Dia. Hole 11/32 Dia. (2) tg. Holes 1/2 & 3/4 Hub = 8.88 (22.6cm) 1 Hub = 9.31 (23.6cm) EFD Two Gang Tandem Pilot Light and Push Buttons 5/16 Dia. (2) tg. Holes 1/2 and 3/4 Hub =.78 (2.0cm) 1 Hub =.94 (2.4cm) 9/32 Dia. Hole PAGE 25

-26 Class I, Div. 1 and 2 Groups C,D Class I, Div. 2 Group B Class II, Div. 1 and 2 Groups E,F,G NEA 3,7CD,9EFG Contender Series Factory Sealed Control Stations and Pilot Lights: Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal Conduit. Furnished with Internal Ground Screw Applications Push Buttons and Selector Switches are used in conjunction with contactors or magnetic starters for remote control of motors. They provide circuit control and /or selection. Pilot Lights provide visual assurance that an electrical function is being performed at a remote or local location Contender Series Factory Sealed Control Stations confine arcing of device within the enclosure, preventing ignition of ignitable atmospheres during control operation of motors and other equipment. Used in classified areas where flammable vapors, gasses or highly combustible dusts are present. For installation in chemical and petrochemical plants, refineries and other process industries or where corrosive elements are present. Features Covers are UL Listed when used on Contender Bodies. Covers and bodies are UL Classified to interchange with Crouse-Hinds EDS covers and bodies. Finish is epoxy powder coat for enhanced corrosion resistance. Large back box for ample wiring room. Ground screw installed in bodies for ground continuity. Corrosion-Resistant stainless steel hex head captive screws hold covers to body. Factory Sealed enclosure eliminates need for adding sealing fittings and compound at each conduit entrance. Heavy-Duty, 10 Ampere 600V rated. Factory Sealed Pilot Lights supplied with jewel/guard assembly and 120V, 6W 6S6 lamp. (LED provided as option) Dozens of possible combinations of push buttons, pilot lights and selector switches. Accurately tapped, tapered hubs for tight, rigid joints and ground continuity. Stainless steel push button shaft operates within stainless steel bushing assuring long, maintenance-free operation. Rocker Arm Push Button Pilot Light Push Button Smooth, rounded integral bushing in each hub protects conductor insulation. Push Button and Selector Switch contacts are silver cadmium oxide which are sealed in lower phenolic chamber isolated from corrosive elements. Assures positive contact and long, trouble-free operation. Enclosed Stainless Steel helper spring prevents accidental operation of Push Button in severe vibration installations. Combination Push Button and Pilot Light Push Button with Dust Cap Selector Switch All front-operated Push Buttons are supplied with lockout type guards as standard. Hole in guard will accept locks with up to 1/4 hasp. Permits locking of Push Button to prevent unauthorized operation. Clearly marked terminals with brass screws and spade terminals assure quick, easy wiring. PAGE 26

Standard aterials Control Stations: malleable iron body with malleable iron cover. SPBB Push Button: Aluminum upper barrel and phenolic lower barrel with nylon plastic button (Dust Cap models have neoprene buttons). SPLS Pilot Light: Aluminum Guard and body assembly; steel clamping ring; and tempered glass jewel. SSBA Selector Switch: Aluminum operator mechanism, nylon cam, and sealed phenolic contact block. Standard Finishes Contender Series Control Stations: body triple coat (1) zinc electroplate, (2) dichromate, and (3) Epoxy Powder Coat. SPBB Push Button, SPLS Pilot Light and SSBA Selector Switch: natural finish. Options Three Position Selector Switches with modified operation. omentary contact right position, spring return to center; maintained contact left position. Suffix S634. Three Position Selector Switches with modified operation. omentary contact left position, spring return to center; maintained contact right position. Suffix S635. Three Position Selector Switches with modified operation. omentary contact right position, spring return to center; maintained contact left position; alternate contacts. Suffix S636. Selector Switch Lockout - Locks two or three position handle in any position. Suffix S349. Pilot Light jewel/guard assembly. Order by suffixes if color desired is other than red as follows: Amber J6; Opal J8; Clear J10; Blue J11; Green J3. Bodies and Covers (single or two gang) in copper-free aluminum. Suffix SA. Securing Rod for Push Button Lockout Guard Suffix S153. LED Pilot Lights are available in lieu of incandescent pilot lights. Order by suffixes for desired color as follows: Red LED1; Green LED3; Amber LED6. -27 Contender Series Factory Sealed Control Stations and Pilot Lights: Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal Conduit; Furnished with Internal Ground Screw For complete list of options, see Catalog Numbering Guide on Pages -2 through -4. Compliances UL Standard 698 Class I, Div. 1 and 2; Class II, Div. 1 and 2. See listing pages for specific groups. Appleton malleable iron products conform to AST A47-77, Grade 32510, which has the following properties; tensile strength, 50,000 psi; yield 32,000 psi; and elongation, 10%. Appleton aluminum products are produced from a high strength copper-free (4/10 of 1% max.) alloy. Securing Rod for Push Button Lockout Guard - available as optional item. Lockout Guard furnished as standard with the Push Button, may also be padlocked. Suffix S153. SPBB factory sealed Push Button used in Contender Series - standard type and unit with dust cap. SPBB Design Features PAGE 27

-28 Class I, Div. 1 and 2 Groups C,D Class I, Div. 2 Group B Class II, Div. 1 and 2 Groups E,F,G NEA 3,7CD,9EFG Contender Series Factory Sealed Push Button Stations: Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal Conduit. 10 Ampere, 600V A.C. ax. for Heavy Duty Use. omentary Contact. Furnished with Internal Ground Screw. U.S. Pat. 3, 699,279 Hub Size, Nameplate Catalog Number Patented Canada 1974 Inches Description arking Dead-End Feed-Thru Single Gang* 1/2 1 Circuit Specify EDS1184 EDSC1184 3/4 Universal EDS2184 EDSC2184 1 EDS3184 EDSC3184 1/2 2 Circuits Specify EDS1190 EDSC1190 3/4 Universal EDS2190 EDSC2190 1 EDS3190 EDSC3190 aintained Contact 1/2 1 Circuit Specify EDS1714 EDSC1714 3/4 Universal EDS2714 EDSC2714 1 EDS3714 EDSC3714 Two Gang* 1/2 2 Circuit Specify EDS1284 EDSC1284 3/4 Universal EDS2284 EDSC2284 1 EDS3284 EDSC3284 1/2 4 Circuits Specify EDS1290 EDSC1290 3/4 Universal EDS2290 EDSC2290 1 EDS3290 EDSC3290 * alleable Iron Body and Cover. For Aluminum Body and Cover, add suffix - SA. For Div. 1, Group B applications, refer to Appleton EFDB Series. PAGE 28

Class I, Div. 1 and 2 Groups C,D Class I, Div. 2 Group B Class II, Div. 1 and 2 Groups E,F,G NEA 3,7CD,9EFG -29 Contender Series Factory Sealed Pilot Light Stations: Combination Push Button and Pilot Light Stations: Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal Conduit. 10 Ampere, 600V A.C. ax. for Heavy Duty Use. omentary Contact. Furnished with Internal Ground Screw. U.S. Pat. 3, 699,279 Hub Size, Nameplate Catalog Number Patented Canada 1974 Inches Description arking Dead-End Feed-Thru Single Gang* 1/2 One EFS1524 EFSC1524 3/4 Pilot Light EFS2524 EFSC2524 1 EFS3524 EFSC3524 1 Pilot Light 2 Pilot Lights 1/2 Two EFS1561 EFSC1561 3/4 Pilot Lights EFS2561 EFSC2561 1 EFS3561 EFSC3561 Two Gang* 1/2 Two EFS1624 EFSC1624 3/4 Pilot Lights EFS2624 EFSC2624 1 EFS3624 EFSC3624 2 Pilot Lights 4 Pilot Lights 1/2 Four EFSC1661 3/4 Pilot Lights EFS2661 EFSC2661 1 EFS3661 EFSC3661 Single Gang* 1/2 1 Circuit Specify EFD1473 EFDC1473 3/4 Universal EFD2473 EFDC2473 1 and 1 Pilot Light EFD3473 EFDC3473 1 Pilot Light 1 Circuit 1 Pilot Light 2 Circuits 1/2 2 Circuits EFD1234 EFDC1234 3/4 Universal EFD2234 EFDC2234 1 and 1 Pilot Light EFD3234 EFDC3234 Two Gang* 1/2 2 Circuits Specify EFD1471 EFDC1471 3/4 Universal EFD2471 EFDC2471 1 and 1 Pilot Light EFD3471 EFDC3471 1 Pilot Light 2 Circuits 2 Pilot Lights 2 Circuits 1/2 2 Circuits Specify EFD1868 EFDC1868 3/4 Universal EFD2868 EFDC2868 1 and 2 Pilot Lights EFD3868 EFDC3868 * alleable Iron Body and Cover. For Aluminum Body and Cover, add suffix - SA. For Div. 1, Group B applications, refer to Appleton EFDB Series Pilot Lights furnished with 6W, 120V A.C. 6S6 lamp and Red Jewel - for other colors, add color suffix for each pilot light: Amber - J6, Blue - J11, Clear - J10, Green - J3, Opal - J8. PAGE 29

-30 Class I, Div. 1 and 2 Groups C,D Class I, Div. 2 Group B Class II, Div. 1 and 2 Groups E,F,G NEA 3,7CD,9EFG 2 Position (2 or 4 Circuit) 3 Position (2 or 4 Circuit) Contender Series Factory Sealed Selector Switches: Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal Conduit. 10 Ampere, 600V A.C. ax. for Heavy Duty Use. Furnished with Internal Ground Screw. Hub Size, Diagram Catalog Number Inches Description Left Center Right Dead-End Feed-Thru Single Gang* 1/2 2 Position None EDS11271 EDSC11271 3/4 2 Circuit EDS21271 EDSC21271 1 EDS31271 EDSC31271 1/2 2 Position None EDS11272 EDSC11272 3/4 4 Circuit EDS21272 EDSC21272 1 EDS31272 EDSC31272 1/2 3 Position EDS11273 EDSC11273 3/4 2 Circuit EDS21273 EDSC21273 1 EDS31273 EDSC31273 1/2 3 Position EDS11274 EDSC11274 3/4 4 Circuit EDS21274 EDSC21274 1 EDS31274 EDSC31274 Selector Switch Operator/Switch Assembly (aintained Contact) Thread Diagram Switch Switch Size Description Left Center Right Assembly Assembly (In., NPS) Only with Cover 1/2 2 Position None SSBA1-2Q EDKB-12 2 Circuit 1/2 2 Position None SSBA2-2Q EDKB-35 4 Circuit 1/2 3 Position SSBA1-3Q EDKB-102 2 Circuit 1/2 3 Position SSBA2-3Q EDKB-345 4 Circuit Selector Switch Operator/Switch Assembly (odified Operations) Thread Diagram Switch Switch Size Description Left Center Right Assembly Assembly (In., NPS) Only with Cover 1/2 3 Position SSBAS-1-3 EDKB-102-S634 2 Circuit omentary contact right position. Spring return to center. aintained contact left position. 1/2 3 Position SSBAS-2-3 EDKB-345-S634 4 Circuit omentary contact right position. Spring return to center. aintained contact left position. Note: Standard legend plate reads HAND OFF AUTO 1/2 3 Position SSBASL-1-3 EDKB-102-S635 2 Circuit omentary contact left position. Spring return to center. aintained contact right position. 1/2 3 Position SSBASL-2-3 EDKB-345-S635 4 Circuit omentary contact left position. Spring return to center. aintained contact right position. Note: Standard legend plate reads AUTO OFF HAND 1/2 3 Position SSBASRA-2-3 EDKB-345-S636 4 Circuit omentary contact right position. Spring return to center. aintained contact left position. Note: Standard legend plate reads STOP RUN START * alleable Iron Body and Cover. For Aluminum Body and Cover, add suffix - SA. For Div. 1, Group B applications, refer to Appleton EFDB Series PAGE 30

Class I, Div. 1 and 2 Groups C,D Class I, Div. 2 Group B Class II, Div. 1 and 2 Groups E,F,G NEA 3,7CD,9EFG -31 Contender Series Rocker Arm and Push Button Stations: Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal Conduit. Factory Sealed. 10 Ampere, 600V A.C. ax. for Heavy Duty Use. Furnished with Internal Ground Screw. 1 Circuit 2 Circuits 2 Circuits Hub Size, Nameplate Catalog Number Inches Description arking Dead-End Feed-Thru Single Gang Rocker Arm Handle alleable Iron Body and Cover 1/2 1 Circuit Specify EDS1596 EDSC1596 3/4 Universal EDS2596 EDSC2596 1 EDS3596 EDSC3596 1/2 2 Circuits Specify EDS1194 EDSC1194 3/4 Universal EDS2194 EDSC2194 1 EDS3194 EDSC3194 Two Gang Rocker Arm Handle alleable Iron Body and Cover 1/2 2 Circuits Specify EDSC1696 3/4 Universal EDS2696 EDSC2696 1 EDS3696 EDSC3696 1/2 4 Circuits Specify EDSC1294 3/4 Universal EDS2294 EDSC2294 1 EDS3294 EDSC3294 4 Circuits Single Gang Single Push Button Hub Size, Catalog Number Inches Description A B Dead-End Feed-Thru 1/2 2 Circuits EDS1192 EDSC1192 3/4 Universal EDS2192 EDSC2192 1 EDS3192 EDSC3192 1/2 2 Circuits EDS1192U1 EDSC1192U1 3/4 Universal EDS2192U1 EDSC2192U1 1 aintained EDS3192U1 EDSC3192U1 Cover Assemblies Nameplate Catalog Number Description arking Cover With Device 1 Circuit Universal Specify EDKBRU1 EDKBRU1 EDKBRU2 EDKBU2L 2 Circuits Universal Specify EDKBRU2 1 Circuit Universal Specify EDKBU1L 2 Circuits Universal Specify EDKBU2L EDKBDPB 2 Circuit Universal Specify EDKBDPB 2 Circuits Universal Specify EDKBDPB (aintained) For Aluminum Body and Cover add suffix - SA. * For Aluminum Cover only, add suffix - A. PAGE 31

-32 Class I, Div. 1 and 2 Groups B*,C,D Class II, Div. 1 and 2 Groups E,F,G Contender Series Push Buttons: Accessories and Parts Single Push Button omentary Contact Description Catalog Number Push Button, Factory Sealed - omentary Contact 10 Amp 600V A.C. Heavy Duty 1/2 thread size. Furnished with 1/2 to 3/4 enlarger, Weather Boot, Guard, Start, Stop and Blank Nameplates. Double Push Button omentary Contact aintained Contact Single Push Button, Universal Double Push Button, Universal SPBB-U1-Q SPBB-U2DBL Push Button (Red), Factory Sealed - aintained Contact 10 Amp 600V A.C. Heavy Duty 1/2 thread size. Furnished with 1/2 to 3/4 enlarger, Guard not furnished. Universal Rectangular Button with Weather Boot Furnished with Start, Stop and Blank Nameplates. SPB-U1-Q NBN-WB Nameplates for Rectangular Push Buttons Blank SNP-B-Q Off SNP-OFF-Q Forward SNP-FWD-Q On SNP-ON-Q Jog SNP-JOG-Q Reverse SNP-REV-Q Run SNP-RUN-Q Open SNP-OPEN-Q Stop SNP-SP-Q Close SNP-CLOSE-Q Start SNP-ST-Q Up SNP-UP-Q Down SNP-DOWN-Q Test SNP-TEST-Q Fast SNP-FAST-Q Low SNP-LOW-Q Slow SNP-SLOW-Q High SNP-HIGH-Q Raise SNP-RAISE-Q Lower SNP-LOWER-Q Reset SNP-RESET-Q Push Button Replacement Locking Guards-Glass Reinforced Polypropylene (Gasketed) Has hole for 1/4 hasp. aintained Switch Guard Single Guard Double Guard Single Guard (aintained Switch) Single Guard Double Guard Single Guard (No Lockout Holes) Double Guard (No Lockout Holes) SPB-LG NPB-LG1 NPB-LG2 NPB-LG1-LL NPB-LG2-LL Push Button Securing Rod with Chain-Stainless Steel (For use with Single Guard Only) NBL-SR ushroom Button with Weather Boot (Gasketed) For use with omentary Contact Black Green Red NRB-BL NRB-GR NRB-RE For use with aintained For use with omentary ushroom Button (For use with aintained Contact) Solid-colored non-metallic button. Red NRB-RE Nameplates For ushroom Head Push Button (omentary & aintained) Start Stop Emergency Stop Blank NPSTQ NPSPQ NPESTPQ NPBQ *Suitable for Class I, Group B when installed in an enclosure rated for Class I, Group B. Effective August, 2008 Copyright 2008 PAGE 32

Class I, Div. 1 and 2 Groups B*,C,D Class II, Div. 1 and 2 Groups E,F,G Contender Series Pilot Lights: Accessories -33 Description Catalog Number Pilot Light, Factory Sealed - Incandescent Furnished with 6S6 120V incandescent lamp, jewel and guard. Has 18 long, type SFF-2 (150 C) pigtail leads. Body has 3/4 straight thread (NPS). Pilot Light With Red Jewel With Green Jewel With Amber Jewel With Blue Jewel With Clear Jewel With Opal Jewel SPLSREB SPLSGRB SPLSAB SPLSBLB SPLSCLB SPLSOPB Chamber Only Pilot Light, Factory Sealed - LED Furnished with candelabra base 120V LED, jewel and guard. Has 18 long, type SFF-2 (150 C) pigtail leads. Body has 3/4 straight thread (NPS). With Red LED, Clear Jewel With Green LED, Clear Jewel With Amber LED, Clear Jewel SPLNSREB SPLNSGRB SPLNSAB Chamber Only (Same as above, less jewel, guard and lamp) SPLSSCB Pilot Light Jewel/Guard Assembly The below catalog numbers indicate an assembly of the Pilot Light Jewels and Guards. Jewels and Guards are not available as separate items. Amber Jewel/Guard Blue Jewel/Guard Clear Jewel/Guard Green Jewel/Guard Opal Jewel/Guard Red Jewel/Guard Clear Bulbs Furnished with candelabra base. 6W, 120V Type 6S6 LED Replacements Furnished with candelabra base. 120 VAC, 10 ma JGBNA JGBNB JGBNC JGBNG JGBNO JGBNR EPL-B6W Red LED Green LED Amber LED EPLLEDR EPLLEDG EPLLEDA Transformer Add Suffix as listed below. Transformer clamps directly to pilot light barrel. Only one pilot light transformer assembly per one gang body. Primary Voltage Lamp Voltage Suffix 220 120 S801 277 120 S802 440 120 S803 550 120 S804 *Suitable for Class I, Group B when installed in an enclosure rated for Class I, Group B. PAGE 33

-34 Contender Series Pilot Lights: Accessories Description Nameplates for Pilot Light Blank Forward Jog Run Stop Start Down Fast Slow Raise Lower Reset Off On Reverse Close Open Up Test Low High Catalog Number LNPBQ LNPFWDQ LNPJOGQ LNPRUNQ LNPSPQ LNPSTQ LNPDOWNQ LNPFASTQ LNPSLOWQ LNPRAISEQ LNPLOWERQ LNPRESETQ LNPOFFQ LNPONQ LNPREVQ LNPCLOSEQ LNPOPENQ LNPUPQ LNPTESTQ LNPLOWQ LNPHIGHQ PAGE 34

Class I, Div. 1 and 2 Groups C,D Class I, Div. 2 Group B Class II, Div. 1 and 2 Groups E,F,G Contender Series: Covers with Pilot Lights or Push Buttons; Covers with Devices for Contender Bodies -35 J1 U1 J1U1 J2 Nameplate Catalog Description arking Number Cover complete with Push Buttons - Factory Sealed For use with EDS Bodies (Furnished with 4 stainless steel captive bolts). 1 Circuit Universal Specify EDKB-U1 2 Circuit Universal Specify EDKB-U2 Cover complete with Pilot Lights and Push Buttons - Factory Sealed 6W120V, Type 6S6 Lamp. For use on standard EDS Bodies (furnished with 4 stainless steel captive bolts). One Pilot Light (red jewel*) and One Universal Circuit Specify EDKB-J1U1 One Pilot Light (red jewel*) and Two Universal Push Buttons Specify EDKB-J1U2 One Pilot Light (red jewel*) EDKB-J1 Two Pilot Lights (red jewel*) EDKB-J2 J1U2 PC120 PC277 Photocontrol 120VAC Photocontrol 208-277VAC EDKB-PC120 EDKB-PC277 Cover complete with Pilot Lights and Push Buttons - Factory Sealed For use with 3-device EDS Bodies (furnished with 8 stainless steel captive bolts). 3 Circuits Specify EDKL-U3 Universal U3 Three Pilot Lights (red jewels*) EDKL-J3 J3 One Pilot Light (red jewel*) Specify EDKL-J1U2 and two universal circuits J1U2 Two Pilot Lights (red jewels*) Specify EDKL-J2U1 and one universal circuit J2U1 Classified for use with Crouse-Hinds Bodies. * For other colors, add color suffix for each pilot light: Amber J6, Blue J11, Clear J10, Green J3, Opal J8. ust be used with Contender Series back boxes. PAGE 35

-36 Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups E,F,G Contender Series: Covers Only for Contender Bodies Description Catalog Number Covers Only - for use on Contender Bodies Supplied with 4 stainless steel captive cover bolts.* Push Button and Pilot Light Covers 3/4 Tapped Openings. 1J One Opening: One Push Button or: One Pilot Light Two Openings: Two Push Buttons or: Two Pilot Lights or: One of Each EDSK-1J EDSK-2J 3PB 2J Three Openings: Three device three Push Buttons or three Pilot Lights, or combination of Push Button(s) and Pilot Light(s) EDSKL-3PB Push Button or Selector Switch Covers 1/2 Tapped Openings Two Openings: Selector Switch or Two Push Buttons (side by side) EDSK-2SP 2SP Push Button, Pilot Light or Selector Switch Covers 3/4 Top and 1/2 Bottom-Tapped Openings One Top and Two Bottom Openings: One Pilot Light, Two Push Buttons (side by side); One Pilot Light, One Selector Switch EDSK-1JSS 1JSS Blank Blank EDSK-B * Cat. No. EDSKL-3PB supplied with 8 stainless steel captive bolts. ust be used with Contender Series back boxes. PAGE 36

Class I, Div. 1 and 2 Groups C,D Class II, Div. 1 and 2 Groups E,F,G ounting Bodies for Contender Series Control Stations UNILETS For use with threaded metal conduit. Furnished with Internal Ground Screw -37 Hub Size, Dead-End Catalog Number Feed-Thru Catalog Number Inches alleable Iron Aluminum alleable Iron Aluminum Single Gang, Two Gang, 3 Device and Tandem Device Bodies Single Gang Three Device Two Gang Single Gang 1/2 EDS171 EDS171-SA EDSC171 EDSC171-SA 3/4 EDS271 EDS271-SA EDSC271 EDSC271-SA 1 EDS371 EDS371-SA EDSC371 EDSC371-SA Two Gang 1/2 EDS172 EDS172-SA EDSC172 EDSC172-SA 3/4 EDS272 EDS272-SA EDSC272 EDSC272-SA 1 EDS372 EDS372-SA EDSC372 EDSC372-SA 3 Device 1/2 EDS147 EDS147-SA EDSC147 EDSC147-SA 3/4 EDS247 EDS247-SA EDSC247 EDSC247-SA 1 EDS347 EDS347-SA EDSC347 EDSC347-SA Tandem 1/2 EDS177 EDS177-SA EDSC177 EDSC177-SA 3/4 EDS277 EDS277-SA EDSC277 EDSC277-SA 1 EDS377 EDS377-SA EDSC377 EDSC377-SA Single Gang Two Gang 3 Device Tandem Unilet Hub Dimensions(in.) Dimensions(cm.) Type (in.) A B C A B C 1/2 6.06 6.81.75 15.40 17.30 1.90 1 Gang 3/4 6.06 6.81.88 15.40 17.30 2.23 1 6.17 7.03 1.00 15.70 17.90 2.54 1/2 6.06 6.81.88 15.40 17.30 2.23 2 Gang 3/4 6.06 6.81.88 15.40 17.30 2.23 1 6.17 7.03 1.00 15.70 17.90 2.54 1/2 8.34 9.19 1.00 21.20 23.30 2.54 3 Device 3/4 8.34 9.19 1.00 21.20 23.30 2.54 1 8.34 9.19 1.00 21.20 23.30 2.54 1/2 11.31 12.09.88 28.70 30.70 2.23 Tandem 3/4 11.31 12.09.88 28.70 30.70 2.23 1 11.44 12.31 1.00 29.00 31.30 2.54 For tandem bodies, external seals must be installed within 5 feet of each conduit entrance for Class I, Groups C and D. PAGE 37

-38 Dimensions Contender Series Pilot Push Buttons, Dust Cap Push Buttons; Pilot Lights; Rocker Arm Push Button Single and Two Gang Combination Pilot Light and Push Button 11/32 Dia. (2) tg. Holes 11/32 Dia. (2) tg. Holes Single Gang Dust Cap Push Button, aintained Push Button and Photo Control 11/32 Dia. (2) tg. Holes Single and Two Gang Rocker Arm Push Button 11/32 Dia. (2) tg. Holes 11/32 Dia. (2) tg. Holes UNILET Hub Dimensions in Inches Dimensions in cm Type Size Inches A B C A B C 1/2 6.06 6.81.75 15.4 17.3 1.9 1-Gang 3/4 6.06 6.51.88 15.4 17.3 2.2 1 6.17 7.03 1.00 15.7 17.9 2.5 1/2 & 3/4 6.06 6.51.88 15.4 17.3 2.2 2-Gang 1 6.17 7.03 1.00 15.7 17.9 2.5 PAGE 38

Class I, Div. 2, Groups B,C,D Class II, Groups E,F,G Class I, Zone 2, Group IIC; Type 3, 3R, 4, 4X (aluminum only); IP66 (without pilot light), IP56 (with pilot light) Div. 2 Contender Series Factory Sealed Control Stations and Pilot Lights A member of the UniCode family. -39 Zone 1 available for certain combinations of push buttons and selector switches; consult factory. Applications For use in wash down areas and other damp, wet and highly corrosive areas. Push buttons and selector switches are used in conjuction with contactors or magnetic starters for remote control of motors in hazardous locations. They provide circuit control and/or selection. Pilot lights provide visual assurance that an electrical function is being performed at a remote or local hazardous location. Features Corrosion-resistant captive stainless steel screws hold covers to body. Silicone gasket ensures high degree of water ingress protection. The Labyrinth switch is rated A600 heavy pilot duty, P150 and IEC AC15. Wide variety of devices and options results in a control station tailor-made to the application. Pilot light employs LED cluster with lifetime of 100,000 hours that can be used at either 120VAC or 240VAC. Optional pilot light has 12V/24V DC ratings. Cover assemblies are UL classified to be used with Crouse-Hinds EDS series mounting bodies. Bodies furnished with internal ground screw and external ground lug. Factory sealed--no external seals required. Standard aterials Backbox: malleable iron or aluminum. Cover: die-cast aluminum. Standard Finishes For malleable iron backbox: Triple coat--(1) Zinc electroplate, (2) Dichromate, and (3) Epoxy Powder Coat. For aluminum backbox and cover: Epoxy Powder Coat. Options UCPL Pilot Light is red as standard; if green is desired, add suffix -JGBG; if amber is desired, add suffix -JGBA; if blue is desired, add suffix -JGBB. For DC pilot light, add suffix -DC to catalog number (push buttons and selector switches have AC and DC ratings as standard). Standard momentary push button colors are listed next to catalog numbers for assembled control stations. To change color to red add suffix -PBRE; to change color to green add suffix -PBGR; to change color to black, add suffix -PBBL; to change color to yellow, add -PBYL; top change; to change color to blue add -PBBU. Push button front operated mushroom head (maintained contact): standard color is red. Also available in green, add suffix - NRBGR; and black, add suffix -NRBBL. Push button front operated mushroom head (monentary contact): standard color is black. Also available in red, add suffix -NRBRE; in green, add suffix - NRBGR; or black, add suffix -NRB- BL. Three position selector switches with modified operation: omentary contact right position, spring return to center, maintained contact left position add suffix -SRC; omentary contact left position, spring return to center, maintained contact right position add suffix -SLC; omentary contact left and right positions, spring return to center add suffix -SRL (only available on -345 with ALT option); Alternate contacts add suffix -ALT. For aluminum mounting body, add suffix -A to catalog number. For complete list of options, see Catalog Numbering Guide on Pages -5, -6. Compliances UL Standards 698, 1604, 2279. CSA Standards C22.2 No.213, C22.2 No. 25, C22.2 No. 30, CAN/ CSA-E79-0, CAN/CSA-E79-1, CAN/ CSA-E79-7, CAN/CSA-E79-18. Effective ay, 2008 Copyright 2008 PAGE 39

-40 Class I, Div. 2, Groups B,C,D Class II, Groups E,F,G Class I, Zone 2, Croup IIC; Type 3, 3R, 4, 4X (aluminum only); IP66 (without pilot light), IP56 (with pilot light) Div. 2 Contender Series Factory Sealed Control Stations and Pilot Lights A member of the UniCode family. 1-Gang Push Button & Pilot Lights omentary Standard Catalog Number Hub Size, Legend Plate arking Inches Description and Device Color Dead-End Feed-Thru 1/2 1 Circuit Start/Green ED2S150U1 ED2SC150U1 3/4 Universal ED2S175U1 ED2SC175U1 1 ED2S110U1 ED2SC110U1 1/2 2 Circuits Start/Green ED2S150U2 ED2SC150U2 3/4 Universal Stop/Red ED2S175U2 ED2SC175U2 1 ED2S110U2 ED2SC110U2 1/2 1 Circuits Start/Green ED2S150J1U1 ED2SC150J1U1 3/4 Universal ED2S175J1U1 ED2SC175J1U1 1 1 Pilot Light Blank/Red ED2S110J1U1 ED2SC110J1U1 1/2 ED2S150J1 ED2SC150J1 3/4 1 Pilot Light Blank/Red ED2S175J1 ED2SC175J1 1 ED2S110J1 ED2SC110J1 1/2 ED2S150J2 ED2SC150J2 3/4 2 Pilot Lights Blank/Red ED2S175J2 ED2SC175J2 1 ED2S110J2 ED2SC110J2 1-Gang Selector Switches Hub Size Diagram Standard Legend Catalog Number Inches Description Left Center Right Plate arking Dead-End Feed-Thru 1/2 2 Position ED2S15012 ED2SC15012 3/4 2 Circuit None On/Off ED2S17512 ED2SC17512 1 ED2S11012 ED2SC11012 1/2 2 Position ED2S15035 ED2SC15035 3/4 4 Circuit None On/Off ED2S17535 ED2SC17535 1 ED2S11035 ED2SC11035 1/2 3 Position ED2S150102 ED2SC150102 3/4 2 Circuit Hand-Off-Auto ED2S175102 ED2SC175102 1 ED2S110102 ED2SC110102 1/2 3 Position ED2S150345 ED2SC150345 3/4 4 Circuit ED2S175345 ED2SC175345 1 Hand-Off-Auto ED2S110345 ED2SC110345 Zone 1 available for certain combinations of push buttons and selector switches, consult factory. Product with iron backbox is NEA 4 rated. With aluminum backbox (-A suffix), product is NEA 4X rated. When a pilot light is selected, assembly is rated IP56. Effective June, 2008 Copyright 2008 PAGE 40

Class I, Div. 2, Groups B,C,D Class II, Groups E,F,G Class I, Zone 2, Croup IIC; Type 3, 3R, 4, 4X (aluminum only); IP66 (without pilot light), IP56 (with pilot light) Div. 2 Contender Series Factory Sealed Control Stations and Pilot Lights A member of the UniCode family. -41 Hub Standard Legend Catalog Number Size Plate arking Inches Description Diagram and Device Color Dead-End Feed-Thru Two-Gang Push Buttons and Pilot Lights 1/2 2 Circuits Push buttons: ED2S250J1U2 ED2SC250J1U2 3/4 Universal and Start/Green ED2S275J1U2 ED2SC275J1U2 1 1 Pilot Light Stop/Red ED2S210J1U2 ED2SC210J1U2 Pilot Light: Blank/Red 1/2 2 Circuits Push buttons: ED2S250J2U2 ED2SC250J2U2 3/4 Universal and Start/Green ED2S275J2U2 ED2SC275J2U2 1 2 Pilot Lights Stop/Red ED2S210J2U2 ED2SC210J2U2 Pilot Light: Blank/Red Standard Legend Plate arking Description Diagram and Device Color Catalog Number Cover Assemblies 1 Circuit Universal Start/Green ED2KBU1 2 Circuit Universal Start/Green ED2KBU2 Stop/Red 1 Pilot Light Blank/Red ED2KBJ1 2 Pilot Light Blank/Red ED2KBJ2 1 Pilot Light and Push button: Start/Green ED2KBJ1U1 1 Circuit Universal Pilot Light: Blank/Red Diagram Standard Legend Description Left Center Right Plate arking Catalog Number 2 Positions None On-Off ED2KB12 2 Circuits Selector Switch 2 Positions None On-Off ED2KB35 4 Circuits Selector Switch 3 Positions Hand-Off-Auto ED2KB102 2 Circuits Selector Switch 3 Positions Hand-Off-Auto ED2KB345 4 Circuits Selector Switch Zone 1 available for certain combinations of push buttons and selector switches, consult factory. Product with iron backbox is NEA 4 rated. With aluminum backbox (-A suffix), product is NEA 4X rated. When a pilot light is selected, assembly is rated IP56. Effective June, 2008 Copyright 2008 PAGE 41

-42 Class I, Div. 2, Groups B,C,D Class II, Groups E,F,G Class I, Zone 2, Croup IIC; Type 3, 3R, 4, 4X (aluminum only); IP66 (without pilot light), IP56 (with pilot light) Div. 2 Contender Series Factory Sealed Selector Switch Replacement Description Diagram Part Number Selector Switches 2 Position, 2 Circuit aintain Contact Left Position aintain Contact Right Position 2 Position, 4 Circuit aintain Contact Left Position aintain Contact Right Position 3 Position, 2 Circuit aintain Contact Left Position aintain Contact Right Position 3 Position, 2 Circuit omentary Contact Right Position Spring Return to Center aintain Contact Left Position 3 Position, 2 Circuit omentary Contact Left Position Spring Return to Center aintain Contact Right Position 3 Position, 4 Circuit aintain Contact Left Position aintain Contact Right Position 3 Position, 4 Circuit, Alternate Contacts aintain Contact Left Position aintain Contact Right Position 3 Position, 4 Circuit omentary Contact Right Position Spring Return to Center aintain Contact Left Position 3 Position, 4 Circuit, Alternate Contacts omentary Contact Right Position Spring Return to Center aintain Contact Left Position 3 Position, 4 Circuit omentary Contact Left Position Spring Return to Center aintain Contact Right Position UCSS12 UCSS22 UCSS13 UCSS13SRC UCSS13SLC UCSS23 UCSSA23 UCSS23SRC UCSSA23SRC UCSS23SLC 3 Position, 4 Circuit, Alternate Contacts omentary Contact Left Position Spring Return to Center aintain Contact Right Position UCSSA23SLC 3 Position, 4 Circuit, Alternate Contacts omentary Contact Left Position Spring Return to Center omentary Contact Right Position UCSSA23SRL Zone 1 available for certain combinations of push buttons and selector switches, consult factory. Effective June, 2008 Copyright 2008 PAGE 42

Class I, Div. 2, Groups B,C,D Class II, Groups E,F,G Class I, Zone 2, Croup IIC; Type 3, 3R, 4, 4X (aluminum only); IP66 (without pilot light), IP56 (with pilot light) Div. 2 Contender Series Factory Sealed Push Buttons and Pilot Lights: Component Parts -43 Assembled Push Buttons Description omentary Black - One Labyrinth Switch omentary Black - Two Labyrinth Switches omentary Red - One Labyrinth Switch omentary Red - Two Labyrinth Switches omentary Green - One Labyrinth Switch omentary Green - Two Labyrinth Switches omentary Yellow -One Labyrinth Switch omentary Yellow - Two Labyrinth Switches omentary Blue - One Labyrinth Switch omentary Blue - Two Labyrinth Switches Part Number UCPB1BL UCPB2BL UCPB1RE UCPB2RE UCPB1GR UCPB2GR UCPB1YL UCPB2YL UCPB1BU UCPB2BU Pilot Lights aintained Black - One Labyrinth Switch aintained Black - Two Labyrinth Switches aintained Red - One Labyrinth Switch aintained Red - Two Labyrinth Switches aintained Green - One Labyrinth Switch aintained Green - Two Labyrinth Switches Red LED Pilot Light (120/240 VAC) Green LED Pilot Light (120/240 VAC) Amber LED Pilot Light (120/240 VAC) Blue LED Pilot light (120/240 VAC) Red LED Pilot Light (12/24 VDC) Green LED Pilot Light (12/24 VDC) Amber LED Pilot Light (12/24 VDC) Blue LED Pilot Light (12/24 VDC) UCPB1BL UCPB2BL UCPB1RE UCPB2RE UCPB1GR UCPB2GR UCPLR UCPLG UCPLA UCPLB UCPLRDC UCPLGDC UCPLADC UCPLBDC Sub Components For Push Buttons Green omentary ushroom Head Red omentary ushroom Head Black omentary ushroom Head UCHGR UCHRE UCHBL Green aintained ushroom Head Red aintained ushroom Head Black aintained ushroom Head UCHGR UCHRE UCHBL Green Cap for omentary Push button Red Cap for omentary Push button Black Cap for omentary Push button Yellow Cap for omentary Push button Blue Cap for omentary Push button UCPBCAPGR UCPBCAPRE UCPBCAPBL UCPBCAPYL UCPBCAPBU Zone 1 available for certain combinations of push buttons and selector switches, consult factory. Effective June, 2008 Copyright 2008 PAGE 43

-44 Div. 2 Contender Series Actuators and Contact Block Description Part Number Actuators Without Contact Blocks for Selector Switches 2 Position Selector Switch UCSS2 3 Position Selector Switch UCSS3 3 Position Selector Switch - Spring Return From Right UCSS3SRC 3 Position Selector Switch - Spring Return From Left UCSS3SLC 3 Position Selector Switch - Spring Return From Right and Left UCSS3SRL 3 Position Selector Switch - Alternate Contacts UCSSA3 Selector Switch 3 Position Selector Switch - Alternate Contacts Spring UCSSA3SRC Return From Right Actuators Without Contact Blocks For Push Buttons 3 Position Selector Switch - Alternate Contacts Spring UCSSA3SLC Return From Left 3 Position Selector Switch - Alternate Contacts Spring UCSSA3SRL Return From Right & Left omentary Actuator Push Button omentary Actuator Push Button - Black omentary Actuator Push Button - Red omentary Actuator Push Button - Green omentary Actuator Push Button - Blue omentary Actuator Push Button - Yellow aintained ushroom Head for Push Button - Black aintained ushroom Head for Push Button - Red aintained ushroom Head for Push Button - Green UCPBBL UCPBRE UCPBGR UCPBBU UCPBYL UCPBBL UCPBRE UCPBGR aintained ushroom Head Push Button omentary ushroom Head for Push Button - Black omentary ushroom Head for Push Button - Red omentary ushroom Head for Push Button - Green UCPBYBL UCPBYRE UCPBYGR Contact Block Labyrinth Switch LAB1 The standard labyrinth switch is available with universal contacts (1 NO/1 NC). The switch is a UL recognized component and is rated for A600 heavy pilot duty (AC) and P150 (DC) as defined by UL 508. It is also IEC AC 15. Hazardous location ratings include Class I, Div. 2, Groups B, C, D and Ex de IIC T6. Glass Reinforced Thermoplastic Body Enclosed Helper Spring Stainless Steel Shaft & Bushing Silver Cadmium Oxide Contacts Stainless Steel Terminal Screw A600 Rating Designation 10A Continous @ 600VAC 7200VA (ake) 720VA (Break) ake Break 120 VAC 60A 6A 240VAC 30A 3A 480VAC 15A 1.5A 600VAC 12A 2A P150 Rating Designation 5A Continuous @ 125VDC Brass Terminal Plate 138VA @ 300VDC 1.1A @ 125VDC PAGE 44

Div. 2 Contender Series Standard Legend Plate arkings and Accessories -45 Legend Plates Grey With Black Letters Green With White Letters Red With White Letters For Push button and Selector Switches For Push button and Selector Switches For Push button and Selector Switches UCLP - (Add Desired arking)* UCLPG - (Add Desired arking)* UCPLR - (Add Desired arking)* For Pilot Lights For Pilot Lights For Pilot Lights UCPLP - (Add Desired arking)* UCPLPG - (Add Desired arking)* UCPLPR - (Add Desired arking)* *Standard legend plate markings listed below. Description Catalog Description Catalog Number Number Standard Legend Plates for: Two Position Selector Switch Three Position Selector Switch Forward - Reverse UCLP-FR Forward - Off- Reverse UCLP-FOR Hand - Auto UCLP-HA Hand - Off - Auto UCLP-HOA On - Off UCLP-OO Run - Off - Jog UCLP-ROJ Start - Stop UCLP-SS Blank UCLP-B Blank UCLP-B Push Buttons (Standard, omentary and aintained ushroom Heads) Blank UCLP-B Fast UCLP-FAST Off UCLP-OFF Slow UCLP-SLOW On UCLP-ON Raise UCLP-RAISE Foward UCLP-FWD Lower UCLP-LOWER Reverse UCLP-REV Open UCLP-OPEN Jog UCLP-JOG Close UCLP-CLOSE Run UCLP-RUN Low UCLP-LOW Start UCLP-ST High UCLP-HIGH Stop UCLP-SP Test UCLP-TEST Up UCLP-UP Reset UCLP-RESET Down UCLP-DOWN Pilot Lights Blank Run On OFF UCPLP-B UCPLP-RUN UCPLP-ON UCPLP-OFF Accessories Device Wrench UCWR1 omentary Push button Locking Guard (included as standard with push button) UCLG1* Close-Up Plug UCPLUG aintained ushroom Head Push button Locking Guard (Locks Button in Down Position) UCPBLG* * Requires a padlock with 1/4 (6mm) hasp. Effective August, 2008 Copyright 2008 PAGE 45

-46 Div. 2 Contender Series: ounting Bodies and Covers Bodies Furnished with Internal Ground Screw alleable Iron ounting Bodies Hub Size Single Gang Two-Gang Tandem Inches Dead-End Feed-Thru Dead-End Feed-Thru Dead-End Feed-Thru 1/2 EDS171 EDSC171 EDS172 EDSC172 EDS177 EDSC177 3/4 EDS271 EDSC271 EDS272 EDSC272 EDS277 EDSC277 1 EDS371 EDSC371 EDS372 EDSC372 EDS377 EDSC377 Aluminum ounting Bodies 1/2 EDS171SA EDSC171SA EDS172SA EDSC172SA EDS177SA EDSC177SA 3/4 EDS271SA EDSC271SA EDS272SA EDSC272SA EDS277SA EDSC277SA 1 EDS371SA EDSC371SA EDS372SA EDSC372SA EDS377SA EDSC377SA Covers Only Description Catalog Number Single Device ED2SK1 Two Device ED2SK2 Blank Cover ED2SKB* *For use on Two Gang box only (only one blank cover may be used on a Two Gang box). PAGE 46

7/8 Tandem Div. 2 Contender Series: Dimensions -47 3.72 (9.4cm) 11/32 1-Gang 2-Gang shown with covers removed Unilet Type Hub Size Dimensions in Inches Dimensions in Centimeters Inches A B C A B C 1/2 6.06 6.81.75 15.4 17.3 1.9 1-Gang 3/4 6.06 6.81.88 15.4 17.3 2.2 1 6.17 7.03 1.00 15.7 17.9 2.5 2-Gang 1/2 & 3/4 6.06 6.81.88 15.4 17.4 2.2 1 6.17 7.03 1.00 15.7 17.9 2.5 Tandem 1/2 & 3/4 11.31 12.09.88 28.7 30.7 2.2 1 11.44 12.31 1.00 29.1 31.3 2.5 PAGE 47

-48 Intraground N1 Series Non-etallic Control Stations UNILETS for Use with Threaded etal Conduit. 10 Ampere, 600V A.C. ax. for Heavy Duty Use. Applications Listed for use in Class 1, Group C and D, Division 1 and 2 atmospheres such as diethyl ether, methyl ethyl keytone, acetone, toluene, No. 3 fuel oil, ammonium hydroxide (20%), benzene, regular unleaded gas, ethyl acetate, hexane and methanol. Not suitable for ethylene dichloride and partially halogenated hydrocarbons. Sealing fittings must be field installed adjacent to enclosure on all conduit runs. Explosionproof. With sealing fittings installed at each conduit entrance, the N1 Series enclosures withstood a hydrostatic test of four times the maximum internal explosion pressure that could be developed from a gas or vapor explosion. Push buttons and selector switches are used in conjunction with contactors or magnetic starters for remote control of motors in hazardous locations. They provide circuit control and/or selection. Pilot lights provide visual assurance that an electrical function is being performed at a remote or local hazardous location. Features First UL listed non-metallic control stations available for Class 1, Div. 1 locations. Non-metallic construction with metal imbedded grounding grid. No need to install special wires and parts for grounding. Feed-thru or dead end grounded 1/2 or 3/4 conduit openings for threaded conduit. Special grounding wire furnished with each box provides safe grounding when cover is removed. Ideal for use in corrosive environments. Non-metallic enclosures with corrosion resistant parts coated with epoxy, Teflon or ylar, these control stations offer unsurpassed resistance Combination Selector Switch and Pilot Light Pilot Light Combination Push Buttons and Pilot Light to chemicals. Unique labyrinth-path construction assures flame-tight joint between body and cover. Silicone gasket, specially designed for the labyrinth-path joint, prevents entrance of moisture without interfering with the venting of cooled hazardous gases and vapors. Typical mechanical properties of 24,500 psi tensile strength, 3% elongation at break, 33,000 psi flexural strength, and 1,200,000 psi flexural modulus. Electrical properties of sample specimens: dielectric strength (in air) of 769 at 1/16. High strength thermoplastic polyetherimide, together with thick walls (5/16 ) and sound structural design (rounded corners) provides superior resistance to impact and crushing. Excellent resistance to ultraviolet light and water. After 336 hours of immersion in water at 82 C and 720 hours of exposure to ultraviolet radiation, there was no appreciable change in tensile strength. Excellent conduit connection strength. UL pull-out and bending resistance tests resulted in no effect on conduit connections. Excellent resistance to attack by fungi and mold. Excellent Heat Deflection Temperature. At 264 psi, in accordance with AST D648 testing procedure, sample specimens rated at 410 F (the temperature required to deflect the material.01 ). UL Temperature Index (continuous use temperature): 338 F electrical properties, 338 F mechanical properties with impact. Superior flammability resistance. After five UL gas burner tests, where flame was applied directly to the box, there was no dripping of burning parts and enclosure retained its integrity. Sample specimens rated V-0 at.03 and 5V at.075. *Cover shown in open position for illustration only. Cover closes automatically when plug is withdrawn. Sealing fittings not furnished. Order from Cat Sec. I. PAGE 48

-49 Intraground N2 Factory Sealed Non-etallic Control Stations UNILETS for Use with Threaded etal Conduit. 10 Ampere, 600V A.C. ax. for Heavy Duty Use. Applications Listed for use in Class 1, Groups B, C and D, Division 2 atmospheres such as diethyl ether, methyl ethyl keytone, acetone, toluene, No. 3 fuel oil, ammonium hydroxide (20%), benzene, regular unleaded gas, ethyl acetate, hexane and methanol. Factory sealedno external seals required. Listed for use in Class II, Division 1 and 2, Groups E, F and G. Dust-tight construction. After 32-hour UL test, no magnesium dust entered the enclosure. Push buttons and selector switches are used in conjunction with contactors or magnetic starters for remote control of motors in hazardous locations. They provide circuit control and/or selection. Pilot lights provide visual assurance that an electrical function is being performed at a remote or local hazardous location. Features Non-metallic construction with metal imbedded grounding grid. No need to install special wires and parts for grounding. Feed-thru or dead end grounded 1/2 or 3/4 conduit openings for threaded conduit. Special grounding wire furnished with each box provides safe grounding when cover is removed. Ideal for use in corrosive environments. Non-metallic enclosures with corrosion resistant parts coated with epoxy, Teflon or ylar, these control stations offer unsurpassed resistance to chemicals. Silicone gasket, specially designed for the labryinth-path point between cover and body, prevents entrance of moisture and dust. olded of high-tensile 30% glass reinforced thermoplastic polyethermide. Enclosure walls are 5/16 thick. Typical mechanical properties of 17,000 psi tensile strength, 3% elongation at break, 27,000 psi flexural strength, and 1,100,000 psi flexural modulus (UL tests showed 18,918 psi tensile strength and 30,675 psi flexural strength). Combination Selector Switch and Pilot Light Electrical properties of sample specimens: dielectric strength of 490 at 1/8 and a comparative track index of 185V/.058. Superior impact resistance. At -32 C for three hours, UL subjected boxes to impact on all four sides by a 2-inch diameter steel ball from a height of 51 inches. There were no signs of damage to enclosure integrity. Extremely low water absorption: only.06% compared to.15% for some thermosets. This important quality assures dimensional stability. Excellent resistance to ultraviolet light and water. After 360 hours of exposure, there was no appreciable change in tensile strength, flexural strength or impact strength. Excellent Heat Deflection Temperature. At 264 psi, in accordance with AST D648 testing procedure, UL gave a rating of 403 F (the temperature required to deflect a sample specimen.01 ). Pilot Light Combination Push Buttons and Pilot Lights UL Temperature Index (continuous use temperature): 266 F electrical properties, 266 F mechanical properties with impact, and 284 F mechanical properties without impact. Superior flammability resistance. After five UL gas burner tests, where flame was applied directly to the box, there was no dripping of burning parts and enclosure retained its integrity. Sample specimens rated V-O at.028 and 5V at.090. Excellent pull-out resistance (200-lb. pull on threaded length of conduit) torque resistance (1000 in./lb. tightening of conduit), crush resistance (100-lb. crushing force) and bending resistance (300 lb. in. bending moment on conduit 10 from box). *Cover shown in open position for illustration only. Cover closes automatically when plug is withdrawn. PAGE 49

-50 Intraground N1 and N2 Series Non-etallic Control Stations UNILETS for use with Threaded etal Conduit. 10 Ampere, 600V A.C. ax. for Heavy Duty Use. Features: General N1 and N2 Series N1 Series: sealing fittings must be field installed adjacent to enclosure on all conduit runs. N2 Series: factory sealed-no external seals required. Heavy-duty, 10 ampere 600V rated. Dozens of possible combinations of push buttons, pilot lights and selector switches. Smooth, rounded integral bushing in each conduit opening protects conduct or insulation. Accurately tapped, tapered conduit openings for tight, rigid joints and ground continuity. Features: N1 and N2 Push Buttons, Selector Switches, and Pilot Lights Stainless steel push button shaft operates within stainless steel bushing, assuring long, maintenance-free operation. Push button and selector switch contacts are silver cadmium oxide which are sealed in lower phenolic chamber isolated from corrosive elements. Assures positive contact and long, trouble-free operation. Enclosed stainless steel helper spring prevents accidental operation of push button in severe vibration installations. Corrosion-resistant stainless steel Teflon coated hex-head cap screws hold covers to body. Push buttons are supplied with lockout type guards as standard. Hole in guard will accept locks with up to 1/4 hasp. Permits locking of push button to prevent unauthorized operation. Clearly marked terminals with brass screws assure quick, easy wiring. Pilot light supplied with jewel/guard assembly and 120V, 6W type 6S6 lamp. Standard aterials N1 series control stations: body and cover of 30% glass-reinforced thermoplastic polyetherimide. N2 series control stations: body and cover of 30% glass-reinforced thermoplastic polyetherimide. SPBB push button: aluminum upper barrel and phenolic lower barrel with nylon plastic button. Glass reinforced polypropylene guard. Silicone weather boot. Aluminum nameplate. SPLS pilot light: aluminum guard and body assembly; steel clamping ring; and tempered glass jewel. SSBA selector switch: aluminum housing, nylon knobs and cams, and sealed phenolic contact block. NBN rectangular button with weather boot: Nylon plastic button with neoprene weather boot. Aluminum nameplate. NRB mushroom button with weather boot: anodized aluminum buttons with neoprene weather boot. Selector switch locking devices and push button securing rods: stainless steel. Cover bolts: stainless steel. Nameplates: aluminum. Receptacles: aluminum. Standard Finishes Cover bolts: Teflon. Nameplates: ylar. Receptacles and pilot light guard and clamping ring: epoxy. Compliances UL Standard 698. Options Three position selector switches with modified operation. omentary contact right position, spring return to center, maintained contact left position. For description and switch diagram, see page 56. Add suffix SRC. Three position selector switches with modified operation. omentary contact left position, spring return to center, maintained contact right position. Add suffix SLC. Alternate contacts add suffix ALT. Selector switch Lockout Ñ locks twoor three-position handle in any position. Suffix LD. Push button front operated mushroom head (momentary contact): In red, add suffix NRBRE; In green, add suffix NRBGR; In black, add suffix NRBBL. Pilot light jewel/guard assembly. Order by suffixes if color desired is other than red, as follows: Amber JGBA; Blue JGBB; Clear JGBC; Green JGBG; Opal JGBO. For colored LED jewel/guard assembly, order by suffixes: red LEDR; green LEDG; amber LEDA. Pilot light transformers for single pilot light per gang. Order by suffix: Primary Lamp Voltage Voltage Suffix 220 120 TR-2 277 120 TR-3 440 120 TR-4 550 120 TR-5 Push button high-impact polystyrene solid colored buttons. See listings. Securing Rod for Push button Lockout Guard. Suffix SR. For complete list of options, see Catalog Numbering Guide on Pages -2 through 4. Aluminum grounding grid, imbedded into the non-metallic enclosure during molding, provides complete grounding system. No field work. No extra grounding wires or parts required. SPBB Design Features PAGE 50

N1 Series (Non-Factory Sealed) Class I, Div. 1 and 2 Groups C,D NEA 3R,4X,7CD,12 N2 Series (Factory Sealed) Class I, Div. 2 Groups B,C,D Class II, Div. 1 and 2 Groups E,F,G NEA 3R,4X,9EFG,12-51 Intraground N1 and N2 Series Non-etallic Push Button and Push Button/Pilot Light Control Stations UNILETS for Use with Threaded etal Conduit. 10 Ampere, 600V A.C. ax. for Heavy Duty Use. N1 Series Neutral Color; N2 Series Blue Color. U.S. Pat. 4,260,863 U.S. Pat 3,699,276 Patented Canada 1980 Patented Canada 1974 Hub Size Nameplate Catalog Number Inches* Description arking N1 Series N2 Series Single Gang Push Buttons omentary Contact Dead-End 1/2 or 3/4 1 Circuit Universal Specify N1D75-U1 N2D75-U1 1/2 or 3/4 2 Circuits Universal Specify N1D75-U2 N2D75-U2 Feed-Thru 1/2 or 3/4 1 Circuit Universal Specify N1DC75-U1 N2DC75-U1 1/2 or 3/4 2 Circuits Universal Specify N1DC75-U2 N2DC75-U2 Single Gang Push Buttons aintained Contact Dead-End 1/2 or 3/4 1 Circuit Universal Specify N1D75-U1 N2D75-U1 Feed-Thru 1/2 or 3/4 1 Circuit Universal Specify N1DC75-U1 N2DC75-U1 Three Device Push Buttons omentary Contact Dead-End 1/2 or 3/4 3 Circuits Universal Specify N1D75-U3 N2D75-U3 Feed-Thru 1/2 or 3/4 3 Circuit Universal Specify N1DC75-U3 N2DC75-U3 1 Circuit 1 Pilot Light 2 Circuit 1 Pilot Light Single Gang Push Button/Pilot Light omentary Contact Dead-End 1/2 or 3/4 1 Circuit Universal Specify N1D75-J1U1 N2D75-J1U1 and 1 Pilot Light 1/2 or 3/4 2 Circuits Universal Specify N1D75-J1U2 N2D75-J1U2 and 1 Pilot Light Feed-Thru 1/2 or 3/4 1 Circuit Universal Specify N1DC75-J1U1 N2DC75-J1U1 and 1 Pilot Light 1/2 or 3/4 2 Circuits Universal Specify N1DC75-J1U2 N2DC75-J1U2 and 1 Pilot Light Single Gang Pilot Lights Dead-End 1/2 or 3/4 1 Pilot Light Specify N1D75-J1 N2D75-J1 1/2 or 3/4 2 Pilot Lights Specify N1D75-J2 N2D75-J2 Feed-Thru 1/2 or 3/4 1 Pilot Light Specify N1DC75-J1 N2DC75-J1 1 Pilot Light 2 Pilot Lights 1/2 or 3/4 2 Pilot Lights Specify N1DC75-J2 N2DC75-J2 For Class I, Div. 1 applications, sealing fittings must be field installed adjacent to enclosure on all conduit runs. For Covers and ounting Bodies, See Page -54; Accessories, Pages -55, 56 and 57; Dimensions, Page -59. * Furnished with 3/4 to 1/2 NPT reducer. PAGE 51

-52 N1 Series (Non-Factory Sealed) Class I, Div. 1 and 2 Groups C,D NEA 3R,4X,7CD,12 N2 Series (Factory Sealed) Class I, Div. 2 Groups B,C,D Class II, Div. 1 and 2 Groups E,F,G NEA 3R,4X,9EFG,12 Intraground N1 and N2 Series Non-etallic Selector Switches: Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded etal Conduit. 10 Ampere, 600V A.C. ax. for Heavy Duty Use. N1 Series Neutral Color; N2 Series Blue Color. U.S. Pat. 4,260,863 U.S. Pat 3,699,276 Patented Canada 1980 Patented Canada 1974 Catalog Number Hub Size Pilot Light Switch Diagram with with out Inches* Diagram Left Center Right Pilot Light Pilot Light Dead-End 1/2 or 3/4 N1D75-J112 N1D75-12 Pilot Light & 2-Pos., N2D75-J112 N2D75-12 2-Cir. Selector Switch 1/2 or 3/4 N1D75-J135 N1D75-35 Pilot Light & 2-Pos., N2D75-J135 N2D75-35 4-Cir. Selector Switch 1/2 or 3/4 N1D75-J1102 N1D75-102 Pilot Light & 3-Pos., N2D75-J1102 N2D75-102 2-Cir. Selector Switch Pilot Light and Selector Switch 1/2 or 3/4 N1D75-J1345 N1D75-345 Pilot Light & 3-Pos., N2D75-J1345 N2D75-345 4-Cir. Selector Switch Feed-Thru 1/2 or 3/4 N1DC75-J112 N1DC75-12 Pilot Light & 2-Pos., N2DC75-J112 N2DC75-12 2-Cir. Selector Switch 1/2 or 3/4 N1DC75-J135 N1DC75-35 Pilot Light & 2-Pos., N2DC75-J135 N2DC75-35 4-Cir. Selector Switch 1/2 or 3/4 N1DC75-J1102 N1DC75-102 Pilot Light & 3Pos., N2DC75-J1102 N2DC75-102 2-Cir. Selector Switch Selector Switch 1/2 or 3/4 N1DC75-J1345 N1DC75-345 Pilot Light & 3-Pos., N2DC75-J1345 N2DC75-345 4-Cir. Selector Switch For Class I, Div. 1 applications, sealing fittings must be field installed adjacent to enclosure on all conduit runs. For Covers and ounting Bodies, See Page -54; Accessories, Pages -53, 56 and 57; Dimensions, Page -59. * Furnished with 3/4 to 1/2 NPT reducer. PAGE 52

-53 Intraground N1 and N2 Series Selector Switch Operators and Cover Assemblies for use with N1 and N2 Series Bodies 10 Ampere, 600V A.C. ax. for Heavy Duty Use. 2 Circuit (2 or 3 Position) N1 and N2 Selector Switch Operator/Switch Assembly (aintained Contact) Thread N1/N2 Switch N1 Switch N2 Switch Size (In., Diagram Assembly Assembly Assembly NPS) Description Left Center Right Only with Cover with Cover 1/2 2 Position, SSBA1-2Q N1K-12 N2K-12 2 Circuit 1/2 2 Position, SSBA2-2Q N1K-35 N2K-35 4 Circuit 4 Circuit (2 or 3 Position) 1/2 3 Position, SSBA1-3Q N1K-102 N2K-102 2 Circuit 1/2 3 Position, SSBA2-3Q N1K-345 N2K-345 4 Circuit N1 and N2 Selector Switch Operator/Switch Assembly (odified Operations) Thread N1/N2 Switch N1 Switch N2 Switch Size (In., Diagram Assembly Assembly Assembly NPS) Description Left Center Right Only with Cover with Cover 2 Circuit (3 Position) 1/2 3 Position, SSBAS-1-3 N1K-102SRC N2K-102SRC 2 Circuit 1/2 3 Position, SSBAS-2-3 N1K-345SRC N2K-345SRC 4 Circuit omentary contact right position. Spring return to center. aintained contact left position. Note: Standard legend plate reads HAND OFF AUTO 1/2 3 Position, SSBASL-1-3 N1K-102SLC N2K-102SLC 2 Circuit Two Position Nameplate 4 Circuit (3 Position) Three Position Nameplate 1/2 3 Position, SSBASL-2-3 N1K-345SLC N2K-345SLC 4 Circuit omentary contact left position. Spring return to center. aintained contact right position. Note: Standard legend plate reads AUTO OFF HAND 1/2 3 Position, SSBASRA-2-3 N1K-637SRC N2K-637SRC 4 Circuit omentary contact right position. Spring return to center. aintained contact left position. Note: Standard legend plate reads STOP RUN START Two Position Nameplates Three Position Nameplates Forward Reverse SLNP-FRQ Forward Off Reverse SLNP-FORQ Hand Auto SLNP-HAQ Hand Off Auto SLNP-HOAQ On Off SLNP-OO Run Off Jog SLNP-ROJQ Start Stop SLNP-SS Blank SLNP-B3 Blank SLNP-BQ Reverse Off Forward SLNP-ROFQ Up Down SLNP-UDQ Auto Off Hand SLNP-AOHQ Run Jog SLNP-RJQ Hand Off Remote SLNP-HORQ Auto Hand SLNP-AHQ 1 Off 2 SLNP-1O2Q Off Remote SLNP-ORQ Jog Off Start SLNP-JORQ Stop Run Start SLNP-SRSQ Local Off Remote SLNP-LORQ Selector Switch Locking Devices Permit locking in any position. Two or Three Positions SBL-3-Q Supplied as standard with aintained Contact Selector Switches PAGE 53

-54 Intraground N1 and N2 Series Non-etallic Covers and ounting Bodies All Covers Supplied with Four Bolts and Blank Nameplate. N1 Series Neutral Color; N2 Series Blue Color. Catalog Number Description N1 Series N2 Series One Opening Two Openings Covers Only for use with Non-etallic ounting Bodies Below Pilot Light or Push Button Covers 3/4 tapped openings One opening: one pilot light N1K-1PL N2K-1PL or one push button Two openings: two pilot lights; two push N1K-2PL N2K-2PL buttons; one pilot light and one push button Push Button or Selector Switch Covers 1/2 tapped openings Two openings: selector switch or N1K-2SP N2K-2SP two push buttons Two Side-by-Side Openings Push Button, Pilot light or Selector Switch Covers One 3/4 top and two 1/2 bottom tapped openings One top and two bottom openings: one pilot light, two push buttons; one pilot light, one selector switch; or three push buttons N1K-3JPB N2K-3JPB Three Openings Hub Size, Catalog Number Description Inches** N1 Series N2 Series Single Gang Non-etallic ounting Bodies For use with Covers Above Dead-End 1/2 or 3/4 N1D75Q N2D75Q Feed-Thru 1/2 or 3/4 N1DC75Q N2DC75Q Furnished with 3/4 to 1/2 NPS reducer. **Furnished with a 3/4 to 1/2 NPT reducer. PAGE 54

Class I, Div. 1 and 2 Groups B*,C,D Class II, Div. 1 and 2 Groups E,F,G -55 Intraground N1 and N2 Series Push Buttons: Accessories and Parts aintained Contact omentary Contact Description Catalog Number Push Button, Factory Sealed - omentary Contact 10 Amp 600V A.C. Heavy Duty 1/2 thread size. Furnished with 1/2 to 3/4 enlarger, Weather Boot, Guard, Start, Stop and Blank Nameplates. Universal SPBB-U1-Q Push Button, Factory Sealed - aintained Contact 10 Amp 600V A.C. Heavy Duty 1/2 thread size. Furnished with 1/2 to 3/4 enlarger, Guard not furnished. Universal Rectangular Button with Weather Boot Furnished with Start, Stop and Blank Nameplates. SPB-U1-Q NBN-WB Nameplates for Rectangular Push Buttons Blank SNP-B-Q Off SNP-OFF-Q Forward SNP-FWD-Q On SNP-ON-Q Jog SNP-JOG-Q Reverse SNP-REV-Q Run SNP-RUN-Q Open SNP-OPEN-Q Stop SNP-SP-Q Close SNP-CLOSE-Q Start SNP-ST-Q Up SNP-UP-Q Down SNP-DOWN-Q Test SNP-TEST-Q Fast SNP-FAST-Q Low SNP-LOW-Q Slow SNP-SLOW-Q High SNP-HIGH-Q Raise Lower Reset SNP-RAISE-Q SNP-LOWER-Q SNP-RESET-Q Push Button Replacement Locking Guards- Glass Reinforced Polypropylene (Gasketed) Has hole for 1/4 hasp. Single Guard (aintained Switch) Single Guard Double Guard Single Guard (No Lockout Holes) Double Guard (No Lockout Holes) Push Button Securing Rod with Chain- Stainless Steel (For use with Single Guard Only) SPB-LG NPB-LG1 NPB-LG2 NPB-LG1-LL NPB-LG2-LL NBL-SR For use with aintained For use with omentary ushroom Button with Weather Boot (Gasketed) For use with omentary Contact Black Green Red ushroom Button (For use with aintained Contact) Solid-colored non-metallic button. Red Nameplates For ushroom Head Push Button (omentary & aintained) Start Stop Emergency Stop Blank *Suitable for Class I, Group B when installed in an enclosure rated for Class I, Group B. NRB-BL NRB-GR NRB-RE NRB-RE NPSTQ NPSPQ NPESTPQ NPBQ PAGE 55

-56 Class I, Div. 1 and 2 Groups B*,C,D Class II, Div. 1 and 2 Groups E,F,G Intraground N1 and N2 Series Pilot Light: Accessories Description Catalog Number Pilot Light, Factory Sealed - Incandescent Furnished with 6S6 120V incandescent lamp, jewel and guard. Has 18 long, type SFF-2 (150 C) pigtail leads. Body has 3/4 straight thread (NPS). Pilot Light With Red Jewel With Green Jewel With Amber Jewel With Blue Jewel With Clear Jewel With Opal Jewel SPLSREB SPLSGRB SPLSAB SPLSBLB SPLSCLB SPLSOPB Chamber Only Pilot Light, Factory Sealed - LED Furnished with candelabra base 120V LED, jewel and guard. Has 18 long, type SFF-2 (150 C) pigtail leads. Body has 3/4 straight thread (NPS). With Red LED, Clear Jewel With Green LED, Clear Jewel With Amber LED, Clear Jewel SPLNSREB SPLNSGRB SPLNSAB Chamber Only (Same as above, less jewel, guard and lamp) SPLSSCB Pilot Light Jewel/Guard Assembly The below catalog numbers indicate an assembly of the Pilot Light Jewels and Guards. Jewels and Guards are not available as separate items. Amber Jewel/Guard Blue Jewel/Guard Clear Jewel/Guard Green Jewel/Guard Opal Jewel/Guard Red Jewel/Guard Clear Bulbs Furnished with candelabra base. 6W, 120V Type 6S6 LED Replacements Furnished with candelabra base. 120 VAC, 10 ma JGBNA JGBNB JGBNC JGBNG JGBNO JGBNR EPL-B6W Red LED Green LED Amber LED EPLLEDR EPLLEDG EPLLEDA Transformer Add Suffix as listed below. Transformer clamps directly to pilot light barrel. Only one pilot light transformer assembly per one gang body. PAGE 56 Primary Voltage Lamp Voltage Suffix 220 120 TR2 277 120 TR3 440 120 TR4 550 120 TR5 *Suitable for Class I, Group B when installed in an enclosure rated for Class I, Group B.

Intraground N1 and N2 Series Pilot Lights: Nameplates -57 Description Nameplates for Pilot Light Blank Forward Jog Run Stop Start Down Fast Slow Raise Lower Reset Off On Reverse Close Open Up Test Low High Catalog Number LNPBQ LNPFWDQ LNPJOGQ LNPRUNQ LNPSPQ LNPSTQ LNPDOWNQ LNPFASTQ LNPSLOWQ LNPRAISEQ LNPLOWERQ LNPRESETQ LNPOFFQ LNPONQ LNPREVQ LNPCLOSEQ LNPOPENQ LNPUPQ LNPTESTQ LNPLOWQ LNPHIGHQ PAGE 57

-58 N1 Series (Non-Factory Sealed)* Class I, Div. 1 and 2 Groups C,D NEA 3R,4X,7CD,12 N2 Series (Factory Sealed) Class I, Div. 2 Groups B,C,D Class II, Div. 1 and 2 Groups F,G NEA 3R,4X,9F,G Intraground N1 and N2 Series 20 Amp U-Line Receptacles And Fire Alarm Station Dead-Front Safety Construction Grounding thru Extra Pole and Shell. U.S. Pat. 4,260,863 U. S. Pa t 3, 346, 709 Patented Canada 1980 Patented Canada 1968 U.S. Pat 4,391,480 Patented Canada 1980 Hub Size Catalog Number Inches** Wire/Pole Volts N1 Series* N2 Series (Neutral Color) (Blue Color) 20 Amp Aluminum Epoxy Coated Receptacles with Non-metallic ounting Box 125VAC,20A, 1HP; 250 VAC, 20A, 2HP Dead-End 1/2 or 3/4 2W,3P 125 N1D75-2023 N2D75-2023 1/2 or 3/4 2W,3P 250 N1D75-20232 N2D75-20232 Feed-Thru 1/2 or 3/4 2W,3P 125 N1DC75-2023 N2DC75-2023 1/2 or 3/4 2W,3P 250 N1DC75-20232 N2DC75-20232 Plugs for above Receptacles These watertight plugs also fit NEA 5-15R, 5-20R or 6-20R receptacles in nonclassified areas. ECP PLUG (Aluminum). Standard plug suitable for use in such areas as refineries, petrochemical plants, and other areas subject to corrosion by ignitible gases and moisture. ECP Plug NCP PLUG (Glass-Filled Polyester). Ideal where moisture or corrosion is a constant problem, such as production facilities on marine platforms and pipeline transportation facilities. Dia- Cable Dia., Cat. No. ECP Plug (odel D) Cat. No. NCP Plug Amps gram Wire/Pole Inches 125V 250V 125V 250V 15 2W,3P.538 to.639 ECP-1523 NCP-1523 NCP Plug 20 2W,3P.538 to.639 ECP-2023 NCP-2023 20 2W,3P.538 to.639 ECP-20232 NCP-20232 Fire Alarm Station Factory Sealed, Universal Contacts, with hammer on chain. Catalog Number Hub Size N1 Series N2 Series Inches** Description (Neutral Color) (Red Color) Dead-End 1/2 or 3/4 Universal N1DC75FA-U1 N2D75FA-U1 2 Position, 1 Circuit Feed-Thru 1/2 or 3/4 Universal N1DC75FA-U1 N2DC75FA-U1 2 Position, 1 Circuit Replacement Glass (For N1 or N2) NFA-G Plug and receptacle is NEA 4X rated with plug installed, or screw cap fully engaged. * For Div. 1 applications, sealing fittings must be field installed adjacent to enclosure on all conduit runs. Do not use in atmospheres containing electrically conductive dusts (most coal dusts are not electrically conductive). **Furnished with a 3/4 to 1/2 NPT reducer. PAGE 58

Dimensions: Intraground N1 and N2 Series Non-etallic Control Stations -59 Push Button/Pilot Light 9/32 Dia. (2) tg. Holes 9/32 Dia. Holes Selector Switch Receptacles U-Line Plug (ECP) (15A, 125V illustrated) PAGE 59

-60 Class I, Div. 2, Groups B,C,D Class II, Groups E,F,G Class I, Zone 2, Group IIC; Type 3, 3R, 4, 4X; IP66 UniCode Series Factory Sealed Control Stations and Pilot Lights Zone 1 available for certain combinations of push buttons and selector switches; consult factory. Applications For use in hazardous areas as defined by the National Electrical Code (NEC), and Canadian Electrical Code (CEC). For use in wash down areas and other damp, wet and highly corrosive areas. Push buttons and selector switches are used in conjunction with contactors or magnetic starters for remote control of motors in hazardous locations. They provide circuit control and/or selection. Pilot lights provide visual assurance that an electrical function is being performed at a remote or local hazardous location. For installation in chemical and petrochemical plants, refineries, pulp and paper processing plants and other industrial applications. Features Corrosion-resistant captive stainless steel screws hold covers to body. Available with two types of explosion proof protection. The Labyrinth switch is rated A600 heavy pilot duty, P150 and IEC AC15.The hermetically sealed switch is rated B300 and Q300 standard duty. Durable materials and construction exceed both UL and IEC environmental requirements including impact. Enclosures constructed of specially formulated fiberglass reinforced thermoset polyester with low surface resistivity that will not hold a static charge. Wide variety of devices and options results in a control station tailor made to the application. Pilot light employs LED cluster with lifetime of 100,000 hours that can be used at either 120VAC or 240VAC. Optional pilot light has 12V/24V DC ratings. Both the standard hub and union hub provide ground path continuity in feedthru applications. Factory sealed no external seals required. Pilot light employs glass jewel. Optional union hub allows temporary rotation of hub for ease of installation. thermoset polyester. Standard hub and ground plate: stainless steel and Noryl. Union hub and ground plate: stainless steel and Noryl. UCPB Push button and UCSS Selector switch Operators: polyester, Valox, and stainless steel. Options UCPL Pilot Light is red as standard; if green is desired, add suffix -JGBG; if amber is desired, add suffix -JGBA; if blue is desired, add suffix -JGBB. Stainless steel mounting feet available, add suffix -SSTG. For DC pilot light, add suffix -DC to catalog number (push buttons and selector switches have AC and DC ratings as standard). Push button front operated mushroom head (maintained contact): standard color is red. Also available in green, add suffix -NRBGR; and black, add suffix -NRBBL. Push button front operated mushroom head (momentary contact): standard color is black. Also available in red, add suffix -NRBRE; in green, add suffix -NRBGR; or black, add suffix -NRBBL. Standard momentary push button colors are listed next to catalog numbers for assembled control stations. To change color to red, add suffix -PBRE; to change color to green, add suffix -PBGR; to change color to black, add suffix -PBBL; to change color to yellow, add suffix to -PBYL; to change color to blue, add suffix -PBBU. For hermetically sealed reed switches on pushbuttons and selector switches add suffix -HSW. Standard aterials Body and cover: fiberglass reinforced Effective ay, 2008 Copyright 2008 PAGE 60

-61 UniCode Series Factory Sealed Control Stations and Pilot Lights Options continued... Three position selector switches with modified operation: omentary contact right position, spring return to center, maintained contact left position add suffix -SRC; omentary contact left position, spring return to center, maintained contact right position add suffix -SLC; omentary contact left and right positions, spring return to center add suffix - SRL (only available on -345 with ALT option); Alternate contacts add suffix -ALT. For complete list of options, see Catalog Numbering Guide on Pages -5 and -6. Compliances UL Standards 698, 1604, 2279 CSA Standards C22.2 No.213, C22.2 No. 25, C22.2 No. 30, CAN/ CSA-E79-0, CAN/CSA-E79-1, CAN/ CSA-E79-7, CAN/CSA-E79-18. A600 Rating Designation 10A Continuous @ 600VAC 7200VA (ake) 720VA (Break) ake Break 120VAC 60A 6A 240VAC 30A 3A 480VAC 15A 1.5A 600VAC 12A 2A P150 Rating Designation 5A Continuous @ 125VDC 138VA @ 300VDC 1.1A @ 125VDC Hermetically Sealed Switch Details Lexan Stroker Braided Copper Cable Thermoplastic Polyester Body Q300 Rating Designation 2.5A Continuous @ 250VDC 69VA @ 300VDC.55A @ 125VDC.27A @ 250VDC Hub Details Two different hubs are available on the UniCode line. Both Versions exceed the UL conduit torque requirements. However, different features are offered by each: Stainless Steel Ground Screw Stainless Steel Set Screw Self Sealing Threads Threaded Stainless Steel Grounding Plate Labyrinth Switch Details Brass Terminal Screw Hermetically Sealed Glass Chamber Standard hubs are of stainless steel and Noryl construction. Stainless steel ground plate is threaded and includes stainless steel set screw and ground screw. Stainless Steel/Noryl Hub Stainless Steel Set Screw Glass Reinforced Thermoplastic Body Stainless Steel Shaft & Bushing Silver Cadmium Oxide Contacts Stainless Steel Ground Screw Enclosed Helper Spring Stainless Steel Terminal Screw Brass Terminal Plate The standard Labyrinth switch is available with universal contacts (1 NO/1 NC). The switch is a UL recognized component and is rated for A600 heavy pilot duty (AC) and P150 (DC) as defined by UL 508. It also rated IEC AC 15. Hazardous Location ratings include Class I, Groups B, C, D, and Ex de IIC T6. Silver Alloy Contacts Actuator agnet The optional hermetically sealed switch is available in NO, NC, or universal (1 NO/ 1 NC) versions. The switch is UL listed and is rated B300 (AC) and Q300 (DC) as defined by UL 508. Hazardous location ratings include Class I, Division 2 Groups B,C,D. B300 Rating Designation 5A Continuous @ 240VAC 3600VA (ake) 360VA (Break) ake Break 120VAC 30A 3A 240VAC 15A 1.5A Self Sealing Threads Un-threaded Stainless Steel Grounding Plate Steel Zinc-Plated Locknut Optional union hubs are of stainless steel and Noryl * construction. Ground plate is stainless steel and not threaded. Hub spins freely for ease of installation; then steel locknut is tightened to secure hub. * Noryl is a registered tradmark of General Electric Corp. PAGE 61

-62 Class I, Div. 2, Groups B,C,D Class II, Groups E,F,G Class I, Zone 2, Group IIC; Type 3, 3R, 4, 4X; IP66 UniCode Series Factory Sealed Control Stations and Pilot Lights Standard Catalog Number Hub Size, Legend Plate arking Inches Description and Device Color Dead-End Feed-Thru Push Buttons omentary Contact 1/2 1 Circuit Start/Green UCS150U1 UCSC150U1 3/4 Universal UCS175U1 UCSC175U1 1 UCS110U1 UCSC110U1 1/2 2 Circuits Start/Green UCS250U2 UCSC250U2 3/4 Universal Stop/Red UCS275U2 UCSC275U2 1 UCS210U2 UCSC210U2 1/2 3 Circuits Blank/Black UCS350U3 UCSC350U3 3/4 Universal UCS375U3 UCSC375U3 1 UCS310U3 UCSC310U3 1/2 4 Circuits Blank/Black UCS450U4 UCSC450U4 3/4 Universal UCS475U4 UCSC475U4 1 UCS410U4 UCSC410U4 aintained Contact 1/2 1 Circuit Emergency UCS150U1 UCSC150U1 3/4 Universal Stop/Red UCS175U1 UCSC175U1 1 UCS110U1 UCSC110U1 Pilot Lights Pilot Light has terminals for 120V or 240V A.C. Uses 8 cluster LED 1/2 1 Pilot Blank/Red UCS150J1 UCSC150J1 3/4 Light UCS175J1 UCSC175J1 1 UCS110J1 UCSC110J1 1/2 2 Pilot Blank/Red UCS250J2 UCSC250J2 3/4 Lights UCS275J2 UCSC275J2 1 UCS210J2 UCSC210J2 1/2 3 Pilot Blank/Red UCS350J3 UCSC350J3 3/4 Lights UCS375J3 UCSC375J3 1 UCS310J3 UCSC310J3 1/2 4 Pilot Blank/Red UCS450J4 UCSC450J4 3/4 Lights UCS475J4 UCSC475J4 1 UCS410J4 UCSC410J4 Zone 1 available for certain combinations of push buttons and selector switches, consult factory. * Push buttons and selector switches with labyrinth switches are Ex de, AEx de. Pilot Lights are Ex me, AEx me. Add -HSW suffix for hermetically sealed switch. Hermetically sealed switches are only Class and Division rated. Effective June, 2008 Copyright 2008 PAGE 62

Class I, Div. 2, Groups B,C,D Class II, Groups E,F,G Class I, Zone 2, Group IIC; Type 3, 3R, 4, 4X; IP66 UniCode Series Factory Sealed Control Stations and Pilot Lights -63 Hub Standard Legend Size Diagram Plate arking Catalog Number Inches Description Left Center Right and Device Color Dead-End Feed-Thru Selector Switches 1/2 2 Positions UCS15012 UCSC15012 3/4 2 Circuits None On/Off UCS17512 UCSC17512 1 UCS11012 UCSC11012 1/2 2 Positions UCS15035 UCSC15035 3/4 4 Circuits None On/Off UCS17535 UCSC17535 1 UCS11035 UCSC11035 1/2 3 Positions UCS150102 UCSC150102 3/4 2 Circuits Hand/Off/Auto UCS175102 UCSC175102 1 UCS110102 UCSC110102 1/2 3 Positions UCS150345 UCSC150345 3/4 4 Circuits Hand/Off/Auto UCS175345 UCSC175345 1 UCS110345 UCSC110345 1/2 3 Positions UCS150345ALT UCSC150345ALT 3/4 4 Circuits Hand/Off/Auto UCS175345ALT UCSC175345ALT 1 Alternate UCS110345ALT UCSC110345ALT Contacts Pilot Lights and Pushbuttons 1/2 1 Circuit Pilots: Blank/Red UCS250J1U1 UCSC250J1U1 3/4 Universal and Push button: UCS275J1U1 UCSC275J1U1 1 Pilot Light Start/Green UCS210J1U1 UCSC210J1U1 1/2 1 Circuit Pilots: Blank/Red UCS350J2U1 UCSC350J2U1 3/4 Universal and Push button: UCS375J2U1 UCSC375J2U1 1 2 Pilot Lights Start/Green UCS310J2U1 UCSC310J2U1 1/2 2 Circuits Pilot: Blank/Red UCS350J1U2 UCSC350J1U2 3/4 Universal and Push button: UCS375J1U2 UCSC375J1U2 1 1 Pilot Light Start/Green UCS310J1U2 UCSC310J1U2 Stop/Red 1/2 2 Circuits Pilot: Blank/Red UCS450J2U2 UCSC450J2U2 3/4 Universal and Push button: UCS475J2U2 UCSC475J2U2 1 2 Pilot Lights Start/Green UCS410J2U2 UCSC410J2U2 Stop/Red Pilot Lights, Push Buttons and Selector Switches 1 Circuit Universal Pilot: Blank/Red 1/2 1 Pilot Light and Push button: UCS350J1U112 UCSC350J1U112 3/4 1 2-positions None Blank/Black UCS375J1U112 UCSC375J1U112 1 2 Circuits Sel. Switch UCS310J1U112 UCSC310J1U112 Selector Switch On/Off 1 Circuit Universal Pilot: Blank/Red 1/2 1 Pilot Light and Push button UCS350J1U1102 UCSC350J1U1102 3/4 1 3-positions, Blank/Black UCS375J1U1102 UCSC375J1U1102 1 2 Circuits Sel. Switch UCS310J1U1102 UCSC310J1U1102 Selector Switch Hand/Off/Auto Zone 1 available for certain combinations of push buttons and selector switches, consult factory. * Pushbuttons and selector switches with labyrinth switches are Ex de, AEx de. Pilot Lights are Ex me, AEx me. Add -HSW suffix for hermetically sealed switch. Hermetically sealed switches are only Class and Division rated. Effective June, 2008 Copyright 2008 PAGE 63

-64 Class I, Div. 2, Groups B,C,D Class II, Groups E,F,G Class I, Zone 2, Group IIC; Type 3, 3R, 4, 4X; IP66 UniCode Series Factory Sealed Control Stations: Cover Assemblies and ounting Bodies Standard Legend Plate arking Description and Device Color Catalog Number Cover Assemblies with Devices 1 Circuit Universal Start/Green UCSKU1 2 Circuit Universal Start/Green UCSKU2 Stop/Red 1 Pilot Light and Pilot Black/Red UCSKJ1U1 1 Circuit Universal Push button: Start/Green 1 Pilot Light and Pilot: Black/Red UCSKJ1U2 2 Universal Push buttons Push button: Start/Green Stop/Red 1 Pilot Light Blank/Red UCSKJ1 2 Pilot Lights Blank/Red UCSKJ2 Description Hub Size Standard Hub Union Hub Inches Dead End Feed-Thru Dead-End Feed-Thru ounting Bodies 1 Device 1/2 UCBB250 UCBBC250 UCBB250U UCBBC250U or 2 Device 3/4 UCBB275 UCBBC275 UCBB275U UCBBC750U 1 UCBB210 UCBBC210 UCBB210U UCBBC210U 3 Device 1/2 UCBB350 UCBBC350 UCBB350U UCBBC350U 3/4 UCBB375 UCBBC375 UCBB375U UCBBC375U 1 UCBB310 UCBBC310 UCBB310U UCBBC310U 4 Device 1/2 UCBB450 UCBBC450 UCBB450U UCBBC450U 3/4 UCBB475 UCBBC475 UCBB475U UCBBC475U 1 UCBB410 UCBBC410 UCBB410U UCBBC410U Zone 1 available for certain combinations of push buttons and selector switches, consult factory. * Push buttons and Selector Switches with labyrinth switches are Ex de, AEx de. Pilot Lights are Ex me, AEx me. Add -HSW suffix for hermetically sealed switch. Hermetically sealed switches are only Class and Division rated. Effective June, 2008 Copyright 2008 PAGE 64

Class I, Div. 2, Groups B,C,D Class II, Groups E,F,G Class I, Zone 2, Group IIC; Type 3, 3R, 4, 4X; IP66-65 UniCode Series Factory Sealed Control Stations: Covers and Replacement Hubs Description Catalog Number Covers Only 1 Device UCC1 2 Device UCC2 3 Device UCC3 4 Device UCC4 Note: Covers sold separately are marked Class 1, Div. 2, Groups B, C, D; Class 1, Zone 2, Group IIC; NEA 3, 3R, 4, 4X only Hub Size Standard Hub Union Hub Inches Catalog Number Catalog Number Replacement Hubs For use with Threaded etal Conduit. 1/2 UCHUB50 UCHUB50U 3/4 UCHUB75 UCHUB75U 1 UCHUB10 UCHUB10U Union Hub Standard Hub Zone 1 available for certain combinations of push buttons and selector switches, consult factory. Effective June, 2008 Copyright 2008 PAGE 65

-66 Class I, Div. 2, Groups B,C,D Class II, Groups E,F,G Class I, Zone 2, Group IIC; Type 3, 3R, 4, 4X; IP66 UniCode Series Factory Sealed Selector Switches Description Diagram Catalog Number Selector Switches 2 Position, 2 Circuit aintain Contact Left Position aintain Contact Right Position 2 Position, 4 Circuit aintain Contact Left Position aintain Contact Right Position 3 Position, 2 Circuit aintain Contact Left Position aintain Contact Right Position 3 Position, 2 Circuit omentary Contact Right Position Spring Return to Center aintain Contact Left Position 3 Position, 2 Circuit omentary Contact Left Position Spring Return to Center aintain Contact Right Position 3 Position, 4 Circuit aintain Contact Left Position aintain Contact Right Position 3 Position, 4 Circuit, Alternate Contacts aintain Contact Left Position aintain Contact Right Position 3 Position, 4 Circuit omentary Contact Right Position Spring Return to Center aintain Contact Left Position 3 Position, 4 Circuit, Alternate Contacts omentary Contact Right Position Spring Return to Center aintain Contact Left Position 3 Position, 4 Circuit omentary Contact Left Position Spring Return to Center aintain Contact Right Position UCSS12 UCSS22 UCSS13 UCSS13SRC UCSS13SLC UCSS23 UCSSA23 UCSS23SRC UCSSA23SRC UCSS23SLC 3 Position, 4 Circuit, Alternate Contacts omentary Contact Left Position Spring Return to Center aintain Contact Right Position UCSSA23SLC 3 Position, 4 Circuit, Alternate Contacts omentary Contact Left Position Spring Return to Center omentary Contact Right Position UCSSA23SRL Zone 1 available for certain combinations of push buttons and selector switches, consult factory. Effective June, 2008 Copyright 2008 PAGE 66

Class I, Div. 2, Groups B,C,D Class II, Groups E,F,G Class I, Zone 2, Group IIC; Type 3, 3R, 4, 4X; IP66-67 UniCode Series Factory Sealed Push Buttons and Pilot Lights: Component Parts Description Catalog Number Assembled Push Buttons omentary Black - One Labyrinth Switch omentary Black - Two Labyrinth Switches UCPB1BL UCPB2BL omentary Red - One Labyrinth Switch omentary Red - Two Labyrinth Switches UCPB1RE UCPB2RE omentary Green - One Labyrinth Switch omentary Green - Two Labyrinth Switches UCPB1GR UCPB2GR omentary Yellow - One Labyrinth Switch omentary Yellow - Two Labyrinth Switches UCPB1YL UCPB2YL omentary Blue - One Labyrinth Switch omentary Blue - Two Labyrinth Switches UCPB1BU UCPB2BU aintained Black - One Labyrinth Switch aintained Black - Two Labyrinth Switches UCPB1BL UCPB2BL aintained Red - One Labyrinth Switch aintained Red - Two Labyrinth Switches UCPB1RE UCPB2RE aintained Green - One Labyrinth Switch aintained Green - Two Labyrinth Switches UCPB1GR UCPB2GR Sub Components For Push Buttons Green omentary ushroom Head Red omentary ushroom Head Black omentary ushroom Head UCHGR UCHRE UCHBL Green aintained ushroom Head Red aintained ushroom Head Black aintained ushroom Head UCHGR UCHRE UCHBL Green Cap for omentary Push button Red Cap for omentary Push button Black Cap for omentary Push button Yellow Cap for omentary Push button Blue Cap for omentary Push button UCPBCAPGR UCPBCAPRE UCPBCAPBL UCPBCAPYL UCPBCAPBU Pilot Lights Red LED Pilot Light (120/240 VAC) Green LED Pilot Light (120/240 VAC) Amber LED Pilot Light (120/240 VAC) Blue LED Pilot Light (120/240 VAC) UCPLR UCPLG UCPLA UCPLB Red LED Pilot Light (12/24 VDC) Green LED Pilot Light (12/24 VDC) Amber LED Pilot Light (12/24 VDC) Blue LED Pilot Light (12/24 VDC) UCPLRDC UCPLGDC UCPLADC UCPLBDC Zone 1 available for certain combinations of push buttons and selector switches, consult factory. * Pushbuttons and Selector Switches with labyrinth switches are Ex de, AEx de. Pilot Lights are Ex me, AEx me. Add -HSW suffix for hermetically sealed switch. Hermetically sealed switches are only Class and Division rated. Effective June, 2008 Copyright 2008 PAGE 67

-68 UniCode Actuators and Contact Blocks Actuators Without For LAB1 For Hermetic Contact Blocks Description Switches Switch 2 Position Selector Switch UCSS2 UCSS2HSW 3 Position Selector Switch UCSS3 3 Position Selector Switch - Spring Return From Right UCSS3SRC 3 Position Selector Switch - Spring Return From Left UCSS3SLC 3 Position Selector Switch - Spring Return From Right & Left UCSS3SRL 3 Position Selector Switch - Alternate Contacts UCSSA3 UCSSA3HSW Selector Switch 3 Position Selector Switch - Alternate Contacts Spring UCSSA3SRC UCSSA3SRCHSW Return From Right 3 Position Selector Switch - Alternate Contacts Spring UCSSA3SLC UCSSA3SLCHSW Return From Left 3 Position Selector Switch - Alternate Contacts Spring UCSSA3SRL UCSSA3SRLHSW Return From Right & Left omentary Push Button For LAB1 & Hermetic Switch omentary Push button - Black omentary Push button - Red omentary Push button - Green omentary Push button - Blue omentary Push button - Yellow aintained ushroom Head - Black aintained ushroom Head - Red aintained ushroom Head - Green Catalog Number UCPBBL UCPBRE UCPBGR UCPBBU UCPBYL UCPBBL UCPBRE UCPBGR omentary ushroom Head - Black UCPBYBL aintained ushroom omentary ushroom Head - Red UCPBYRE Head Push Button omentary ushroom Head - Green UCPBYGR Contact Blocks Circuit Type Catalog Number Hermetic Switch Labyrinth Switch Hermetic Switch Universal (1 N.O., 1 N.C.) HSWU1 Hermetic Switch rated for 1 N.O HSWNO Class I, Div. 2, Groups B,C,D 2 N.O HSW2NO 1 N.C. HSWNC 2 N.C. HSW2NC Labyrinth Switch Universal (1 N.O., 1 N.C.) LAB1 The Standard labyrinth switch is available with universal contacts (1 NO/1 NC). The switch is a UL recognized component and is rated for A600 heavy pilot duty (AC) and P150 (DC) as defined by UL 508. It also rated IEC AC 15. Hazardous location ratings include Class I, Groups B, C, D and Ex de IIC T6 A600 Rating Designation 10A Continuous @ 600 VAC 7200VA (ake) 720VA (Break) ake Break 120VAC 60A 6A 240VAC 30A 3A 480VAC 15A 1.5A 600VAC 12A 2A P150 Rating Designation 5A Continuous @125VDC 138VA @ 300VDC 1.1A @ 125VDC PAGE 68

UniCode Series Standard Legend Plate arkings and Accessories -69 Legend Plates Grey With Black Letters Green With White Letters Red With White Letters For Push button and Selector Switches For Push button and Selector Switches For Push button and Selector Switches UCLP - (Add Desired arking)* UCLPG - (Add Desired arking)* UCPLR - (Add Desired arking)* For Pilot Lights For Pilot Lights For Pilot Lights UCPLP - (Add Desired arking)* UCPLPG - (Add Desired arking)* UCPLPR - (Add Desired arking)* *Standard legend plate markings listed below. Description Catalog Description Catalog Number Number Standard Legend Plates for: Two Position Selector Switch Three Position Selector Switch Forward - Reverse UCLP-FR Forward - Off- Reverse UCLP-FOR Hand - Auto UCLP-HA Hand - Off - Auto UCLP-HOA On - Off UCLP-OO Run - Off - Jog UCLP-ROJ Start - Stop UCLP-SS Blank UCLP-B Blank UCLP-B Push Buttons (Standard, omentary and aintained ushroom Heads) Blank UCLP-B Fast UCLP-FAST Off UCLP-OFF Slow UCLP-SLOW On UCLP-ON Raise UCLP-RAISE Forward UCLP-FWD Lower UCLP-LOWER Reverse UCLP-REV Open UCLP-OPEN Jog UCLP-JOG Close UCLP-CLOSE Run UCLP-RUN Low UCLP-LOW Start UCLP-ST High UCLP-HIGH Stop UCLP-SP Test UCLP-TEST Up UCLP-UP Reset UCLP-RESET Down UCLP-DOWN Pilot Lights Blank Run On OFF UCPLP-B UCPLP-RUN UCPLP-ON UCPLP-OFF Accessories Device Wrench UCWR1 omentary Push button Locking Guard (included as standard with push button) aintained ushroom Head Push button LockingGuard (Locks Button in Down Position) UCLG1* UCPBLG* Close-Up Plug UCPLUG 2 Stainless Steel ounting Feet SSTG * Requires a padlock with 1/4 (6mm) hasp. Effective August, 2008 Copyright 2008 PAGE 69

-70 Dimensions: UniCode Series Factory Sealed Control Stations and Pilot Lights 4.06 (10.31 cm) 5.95 (15.11 cm) 5.82 (14.78 cm) 5.36 (13.61 cm) 2.94 (7.47 cm) Knockout 30.58 mm Close-up Plug Push Button, omentary Contact 2.25 (5.72 cm) typical Push Button, omentary Contact ushroom Head Push button, aintained Contact ushroom Head 4.38 (11.13 cm) 7/32 Dia. (4) tg. Holes Enclosure shown with cover removed 3.50 (8.89 cm) 2.88 (7.32 cm) 5.82 (14.78 cm) 5.36 (13.61 cm) 5.33 (13.54 cm).26 (.66 cm) Knockout 30.58 mm Close-up Plug Pilot Light 3.38 (8.59 cm) 3.86 (9.80 cm) Push Button, omentary Contact Selector Switch 9/32 Dia. (4) tg. Holes Enclosure shown with mounting feet (sold separately). PAGE 70 Dimensions in Inches Dimensions in Centimeters Enclosures A B C D A B C D 1 or 2 Device 6.38 7.56 8.13 8.77 16.21 19.20 20.65 22.28 3 Device 8.63 9.81 10.38 11.02 21.92 24.92 26.37 27.99 4 Device 10.88 12.06 12.63 13.27 27.64 30.63 32.08 33.71 Dimensions in Dimensions in Hub Inches Centimeters Size, Inches E F E F 1/2 1.23 1.06 3.12 2.69 3/4 1.25 1.06 3.18 2.69 1 1.28 1.31 3.25 3.33

Class I, Div. 1 and 2 Groups B,C,D Class II, Div. 1 and 2 Groups E,F,G NEA 4,7,9 AEPGI Series Ground Indicator: Explosionproof, Dust-Ignitionproof -71 Applications The Grounding Device is used to logically indicate the presence of grounding of tank cars or tank trucks before and during transfer of combustible materials. When connected to a truck prior to loading or unloading, the presence of a safe ground is indicated by a green light and the absence of ground is indicated by a red light. Interlocking circuitry will prevent pumps from starting until a ground is established or shut pumps down if a ground is lost at any time during loading or unloading. This intrinsically safe circuit and explosionproof enclosure enables the ground device to be used in hazardous location areas. Features: Clamp and Cable - The coiled cable provided: 2 conductor #14 SJEOO-WA terminated with an alligator ground clamp. Operating temperature -58 F to 221 F (150 C to 105 C). Power requirements - 115/240VAC. Control contacts - 250VAC - 10 amp continuous. Indicators - one green light for Satisfactory Ground, one red light for No Ground. Compact design. Hinges supplied. External ground lug and internal ground lug supplied; accommodate #14 through #2 AWG. Standard aterials: Enclosure: Copper-free aluminum. Standard Finishes: Epoxy powder coat on enclosure. Compliances: UL Listed Standard 698 CSA Certified Coiled Cable Length Conduit Entries Catalog No. 25 feet 3/4 NPT AEPGI 50 feet 3/4 NPT AEPGI-50 TG TG For Groups B and C, all conduit entries must be sealed adjacent to enclosure. Effective June, 2008 Copyright 2008 PAGE 71