Uninterruptible Power System

Similar documents
Uninterruptible Power System

Uninterruptible Power System

Uninterruptible Power System

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

Informer Compact Series

Installation and Operation Back-UPS BX550CI-CN

BRAVER UPS. (Uninterruptible Power System) User s Manual

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

U n i n t e r r u p t i b l e P o w e r S y s t e m

Uninterruptible Power Supply USER MANUAL Version 1.4. Always On UPS Systems Inc. GES-801L, GES-102L, GES-152L, GES-202L, GES-302L

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

1. INTRODUCTION. Features:

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Installation and Operation Manual Back-UPS BX1100CI-CN

Limousin II User Manual

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

Installation and Operation Manual Back-UPS BR800/1100CI-IN

Back-UPS CS Back-UPS CS 350

Sola/Hevi-Duty S3K Series Mini-Tower UPS

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

U P S. Uninterruptible Power System Unterbrechungsfreie Stromversorgung

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Installation and Operations Manual

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

UPS Wizard User s Manual

CP900EPFCLCD User s Manual K

661-SK [1]I:\USV_TEAM\USV_MANUAL\Roline\LineSecureII\661-SK [1].d oc U P S. Uninterruptible Power System

User Manual Rittal PMC UPS 6kVA

UTILITY INPUT MAINS OUTLET

Uninterruptible Power Supply

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

USER MANUAL ONLINE UPS

General Precautions. Personnel Precautions

Eclipse Plus VA UPS and Surge Suppressor User s Manual

FALCON ELECTRIC, INC.

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

3000VA 120/208/230VAC

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

User Manual 1KVA-5KVA INVERTER / CHARGER

Sine Wave Solar UPS. Owner s Manual. Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology.

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

Liebert PowerSure PSI UPS

Installation and Operation Manual Back-UPS BR1000-CH

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

USER MANUAL. PowerMust 1080 LCD (1KVA), Online, IEC PowerMust 2016 LCD (2KVA), Online, IEC PowerMust 3024 LCD (3KVA), Online, IEC

Foreword. Manual instruction

Sola 3000 Guide Specifications

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

Mission 1K Single Phase UPS

OPERATING INSTRUCTION UPS PROTECT A. PROTECT A PROTECT A. 1400

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 2400VA and 3000VA Smart-UPS RT 100 and 120VAC Uninterruptible Power Supply

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

GSL Electronics Modified Sine Wave Power Inverters

Foreword

PR1000ELCD / PR1500ELCD User s Manual

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

OutdoorXUPS-600AHV-8364

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

TECHNICAL DATA SHEET KVA UPS Systemss

Installation and Operation Smart-UPS SUA500PDR

Application. Battery. Public Grid GS HYBRID INVERTER

1250W APS X Series 12VDC 230V Inverter/Charger with Auto Transfer Switching, 2 C13 Outlets

OWNER'S OPERATING MANUAL

02/15/01. Powerware User s Guide VA.

MM-AVR UPS Series User s Manual

User Manual 1KVA-5KVA INVERTER / CHARGER

USER MANUAL. Uninterruptible power supply MODEL: 53965,

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

Delta UPS - Ultron Family. HPH Series, Three Phase 20/30/40/60 kva 208V. User Manual. The power behind competitiveness

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

CX-SERIES ADVANCED BATTERY CHARGER

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Transcription:

USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS AVR Protection Compact & Reliable Design st Edition Uninterruptible Power System IP-00-a8-09

NOTES IMPORTANT SAFETY INSTRUCTIONS Thank you for selecting this uninterruptible power system (UPS). It provides you with better protection for connected equipment. Please read this manual This manual provides safety, installation and operating instructions than will help you derive the fullest performance and service life that the UPS has to offer. Please save this manual It includes important instructions for the safe use of this UPS and for obtaining factory service should the proper operation of the UPS come into question. Please save or recycle the packaging materials The UPS`s shipping materials were designing with great care to provide protection from transportation related damage. There materials are invaluable if you ever have to return the UPS for service. Damage sustained during transit is not covered under the warranty.

TROUBLE SHOOTING If the UPS failed to operate properly, please review the following checks firstly. If the problem remain, please consult sales agent for service. Is the Master power switched on? Is the UPS plugged into a correctly working outlet? Is the line voltage within the rating specified? Is the fuse on the rear panel blown? Is the UPS over loaded? Is battery not fully charged? Dead battery? Charger failure? Please provide the following information when call for service.. Model number, serial number.. Date of the problem occurred, date of purchase.. Full description of the problem including load, LED, and alarm status, installation condition, working environment, etc. Trouble-Shooting Chart Problem Possible Cause Caution To Take Front panel switch Turn on switch. in off position. No light, and no alarm Rear panel fuse (UPS not on) Replace fuse restart UPS. burnout. Power cord lose Check input power. No Line-on LCD Power cord lose Check input power. light, and alarm beeps AC Fuse burnout. every few seconds. Replace fuse, if problem remains, call for service. Backup time is less Battery is not fully least 6 hours, re-test the than the rating. charger failure. Recharge the battery for at backup time. If problem remains, call for service. CAUTION The UPS contains voltage that are potentially hazardous. All repairs should be performed by qualified service personal. The UPS has its own internal energy source (battery). The output receptacles may be alive even when the UPS is not connected to an AC supply. The UPS is suitable for computers and electronic equipment with substantially rectifier or capacitive loads, not suitable for electronic equipment with significant inductive loads, such as motors & fluorescent lamps. Be sure to operate within the power rating of the UPS. Below / or / of rated power is recommended for longer backup time & longer battery life. Do not place the UPS near excessive humidity, under sunshine, or close to heat-emitting sources. If the UPS is out of order, please detach power cord and consult your dealer right away. Do not remove cover if there is no serviceable part inside. The unit should be supplied by grounded source. Do not operate the unit without ground source. The socket-outlet should be installed near the equipment and be easily accessible. Do not plug the UPS power cord into itself. That will result in a safety hazard. Installation should be performed by a qualified technician or electrician in accordance with local electrical codes.

BATTERY FACTS The battery is the only periodically serviceable parts in the UPS. An expected life is approx. 5 years. However, frequent long discharges or ambient temperatures above 80 F will shorten battery life. Therefore, it is recommended to replace the batteries every years after initiating the unit. SYSTEM CONCEPT The purpose to present this chapter is to give you more precise conception about how UPS works... Block Diagram Recharge batteries every months is necessary if it is not in use because it may cause batteries over-drain. INPUT OUTPUT WARNING Only a qualified technician should replace the battery. Batteries have high short-circuit current capacity; mistakes in connecting or disconnecting can cause connections to arc or weld and could cause severe burns. CHA. AVR. INV. STORAGE The UPS should only be stored if the battery is fully charged. Avoid storage temperatures above 80 F as battery life is significantly shortened. Every 90 days remove the unit from storage and plug it in for hours to recharge the batteries. Batteries may be damaged if left in storage and not recharge every 90 days. IMPORTANT NOTICE Please use same type and same rating of batteries for replacement. Do not replace it with the battery that exceeds specified rating. Fig. shows how UPS works.. Normal Operation There are two main loops when AC Utility normal the AC output loop and the battery charging loop. The AC output gets power from AC utility input and pass through AVR to support power to load. In the same time, the AC utility input is converted by AC/DC CHA and support charging power to charge batteries. INPUT OUTPUT AVR. CHA. INV. Fig. shows how the UPS works when AC Utility normal.

INSTALLATION AND OPERATION Upon receipt of the UPS, inspect the shipping carton for damage. If there is any obvious damage, immediately report it to the selling dealer or the delivering carrier. If there is no damage to the shipping carton, unpack the unit and inspect the unit for damage. The UPS is designed for installation in a protected environment within a temperature range from F to 0 F and relative humidity of 0 90% without condensation. Do not block inlets and outlets. Install the system in a location free from excessive dust and chemical fumes. Check the identification label to verify the UPS voltage and power rating match the available line voltage and load requirements. Installation:. Check if the main switch on the UPS front panel is in the off position and insure that the voltage of the AC utility source corresponds to the nameplate on the UPS rear panel.. Plug the power cable into the grounded socket. If indicators of LINE-ON & CUT-OFF LCD light on, it mean AC power is normal, although UPS is under CUT-OFF status, it still will automatically start to charge by itself.. Push the main switch, then the Load Level LCD will light on for seconds and CUT-OFF LCD will light off. The UPS will then get ready and start to work normally.. Connect your PC with UPS, then turn on PC. Be sure to check the Load Level LCD indicator and DO NOT OVERLOAD it over 00%. To simulate AC failure (Push UPS test switch) can help to insure whether UPS is in good condition or not. It is designed to alarm every seconds and with BACK-UP LCD light on when simulation starts. If the CUT-OFF LCD is on, it means UPS fault or BATTERY fault. Then you have to contact your local service center 5. When battery approaches low level, alarm will beep every second until auto shut down 6. The conditions UPS will automatically shut down: a. Battery low b. Short circuit c. Overload d. UPS fault OVERVIEW Front Panel. UPS Test Switch: When UPS is working under AC mode, it also activates the UPS`s self-test by press the bottom.. Master Power Switch: Turn on/off the UPS.. LINE-ON: AC Normal.. AVR Protection LCD: When AVR is working under protection mode, the light will turn on. 5. BACK-UP: Battery in back-up 6. Over Load: If the UPS is overloaded, the light will turn on and the alarm will sound continuously.. UPS Cut-off: Overload or Cut-off 8. Battery Level: A bar graph showing how much of the UPS battery is being used. 9. Load Level: A bar graph showing how much of the UPS power is being used. Rear Panel. AC line input socket: Connect power cable from the UPS to AC utility.. AC input fuse: Contain the fuse to protect the UPS from over curren from incoming AC utility.. Output receptacles: Connect power cables of computer equipment to this sockets.. Computer interface: This socket combines relay contact signals and RS- signals(option) on DB9 connector. 5. Phone/Fax/Modem jack: Telecom transfer ports provide users to extend the applications. 6. EXT. Battery: Connect external battery cable for battery bank to the UPS.. UPS setup switch: Dip. Low load(below 50w) auto-shut OFF. Low load auto-shut ON. Dip. DC-start ON. DC-start OFF. Dip. Buzzer auto-reset OFF. Buzzer auto-reset ON.

CONTENTS PAGE. CAUTION..... INTRODUCTION SYSTEM DESCRIPTION... FEATURES.... SYSTEM CONCEPT BLOCK DIAGRAM... NORMAL OPERATION... AC UTILITY FAILURE.. OVERVIEW FRONT PANEL 5 REAL PANEL 5 PICTURE..6 EXT. BATTERY Operation process for UPS being fitted with additional Battery Bank for extending back-up time:. Connect AC Main Power under UPS machine is no load condition.. To make sure Battery group voltages are same as DC BUS voltages of UPS machine.. Well connect two devices between UPS machine and Battery Bank.. Push UPS test button to check UPS machine is working normal to switch to Battery Back-up mode. Above UPS operation process must be ensured turn on AC Main Power firstly, then connect Battery Bank, In order to avoid spark when connect cable wire between UPS machine and Battery Bank. 5. INSTALLATION AND OPERATION 8 6. COMPUTER INTERFACE...9. BATTERY FACTS 0 + 8. SPECIFICATIONS 9. TROUBLE SHOOTING... 0. EXT. BATTERY....

INTRODUCTION SPECIFICATIONS System Description Capacity VA 00VA 500VA 000VA 500VA The product is line interactive UPS with the newest technology and powerful function. The Line Interactive UPS is with AVR function allows input voltage range from 5% to 5%, including on line voltage boost-up & buck down. An ideal protection equipment for critical connected loads. In addition, This UPS provides advanced single telephone line or modem surge suppression through the modular connectors on the back panel. The Line Interactive UPS and RUPS000 monitoring software (Optional kits) makes our computer operate intelligent and provides you with the ability of perfect protection of your critical devices. Input Output Battery Voltage Frequency Voltage (Batt. Mode) Frequency Waveform Transfer Time Battery Type 0VAC, 5VAC, 0VAC, 0VAC, 0VAC or 0VAC 5% 50Hz or 60Hz 5% 0VAC, 5VAC, 0VAC, 0VAC, 0VAC or 0VAC V/AH *PCS 5%, 50Hz or 60Hz Hz Modified sine wave Less than ms (typical) V/.5AH *PCS HR W *PCS V/AH *PCS Features Microprocessor design for true RS- (Option). Line interactive design. User-friendly LCD display. Provide boost and buck AVR to stabilize input voltage. Provides lightning, surge, overload, and short-circuit protection. Built-in CCCV battery charger and battery over drain protection. No load auto shutdown (Dip switch setup). Load level and Battery level display. Buzzer alarm auto-reset (Dip switch setup). Auto restart when AC recovery. Cold start function (Dip switch setup). Tel / Modem / Fax / Internet surge suppression. Option Bundle software Automatically save your valuable files before auto shutdown. Recharge Time 5 hours to 90% of full capacity LCD indicator for line on, battery back-up, AVR protection, Indicator LCD Overload and cut-off, Load and battery level Battery Back-up Sounding every seconds Alarm Battery Low Sounding every second Overload Continue beeping sound Overload Fuse & current limited Protection Short Circuit Fuse & current limited & cut-off Batt. Low Cut-off No battery drain after cut-off Physical Dimension, D*W*H 08**9 mm Operating Temperature -0 at full load, 0~90% relative humidity Environment (non-condensing) Noise Level Less than 0db (at meter) Contact Closure DB9 connector for connecting with Rups-000 software Interface (Option) Smart RS- (Option) True RS- with UPSilon-000 software (Option)

. AC Utility Failure If AC utility fails, the UPS quickly detects the problem and activates the inverter. The inverter. The DC/AC inverter changes DC power from the batteries into AC and provides continuous uninterruptible power to load. INPUT OUTPUT AVR. INV. CHA. COMPUTER INTERFACE The computer interface (DB9 port) on the back of the UPS may be connected to a host computer. This port allows the computer to monitor the status of the UPS and control the operation of the UPS. The UPSilon 000 ((option),m50 Cable), provides complete On-Screen power management to the UPS and computer systems. Its major functions normally include some or all the following: Real-time UPS status on screen. All history records in memory. Auto orderly shutdown for computer & UPS. Multi-server support. Auto file save even without filename preset. Scheduled switch on/off daily or weekly. Pin out information: Fig. shows how the UPS works when AC Utility Failure PIN# Description PIN RS DTR, must keep in high state PIN Line fail, normally open, active close PIN N.C. PIN Common for PIN,5 PIN5 Battery low, normally open, active close PIN6 Two purposes on this pin ()Remote shut down, keep this pin high (+5~+V) for S will turn off the UPS ()RS Receiver Rx PIN Ground for PIN 6,9 PIN8 N.C. PIN9 RS Transmitter TX I/O Input Output Output Input Output 5 5 9 8 6 6 8 9

I NT ERNET IN OU T I NTERNET Picture: Front Panel: Rear Panel: NEMA5-5R: 5 6 CAUTION: RISK OF ELECTRIC SHOCK. DO NOT REMOVE COVER AC/BATTERY OUTPUTS - - 5 AC/BATTERY OUTPUTS I N OUT 6 EXT. BATTERY AC FUSE AC FUSE 8 9 AC INPUT REMOTE Buzzer auto-reset ON Dc-start ON AC INPUT REMOTE Buzzer auto-reset ON Dc-start ON 00VA, 500VA, 000VA 500VA IEC-0: CAUTION: RISK OF ELECTRIC SHOCK. DO NOT REMOVE COVER AC/BATTERY OUTPUTS 5 AC/BATTERY OUTPUTS AC FUSE 6 EXT. BATTERY AC FUSE AC INPUT REMOTE Buzzer auto-reset ON Dc-start ON AC INPUT REMOTE Buzzer auto-reset ON Dc-start ON 00VA, 500VA, 000VA 500VA - 6 - - -