up to 63 A (1 module per pole)

Similar documents
RX 3 M.C.B A up to 63 A

RX 3 M.C.B A up to 63 A

(1,5 modules per pole)

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

TX³ RCCBs 2P up to 100 A

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

DX³ RCCBs - ID 4P up to 100 A

Phase + Neutral, neutral on right side

DX³ 4-pole RCBO 6000 A/10 ka

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Cat N 3. OVERALL DIMENSIONS

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Btdin RCBO 6000A up to 63A (2P)

DX³ RCBO 6000A Phase + Neutral, neutral on left

DX³ RCBO 6000 A Phase + Neutral, neutral right side

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

DX³ RCBO 6000A Phase + Neutral, neutral on right

R.C.B.O. SP / 1 module

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Industrial Contactors CTX 3 3P 185A - 800A

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Magnetic only

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX earth leakage DPX 3 -I earth leakage

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

DRX 125 Circuit breaker (not adjustable)

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DRX 250 B/N/H Circuit breaker (not adjustable)

DRX 100 B/N/H Circuit breaker (not adjustable)

New DX 3 High rating & breaking capacity

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

COMPLETE SOLUTIONS FOR POWER PROTECTION

DPX Electronic + earth leakage

DMX 3 -I 2500 switch disconnectors

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

Essential equipment for all your requirements

Thermal-magnetic Miniature Circuit Breaker 4230-T...

DPX moulded case circuit breakers

Thermal-magnetic Miniature Circuit Breaker 4230-T...

DPX 1600 Electronic release

DPX 630 Electronic release

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

AF40... AF96 3-pole contactors Technical data

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Thermal magnetic and trip-free switches

Viking 3 - Screw connection Disconnect terminal blocks

NB1 Miniature Circuit Breaker

Low Voltage A GE Power Controls Company. General catalogue

cor Long Run Experience

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Protection components

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

ZS4-SF1 Screw Clamp Terminal Block

MS General Information Extended Product Type: MS

Vistop TM isolating switches 63 to 160A

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

XL³ 400 metal distribution cabinets, free-standing enclosures and cable compartments

C60H-DC C curve. Catalogue numbers

Modular contactors and relays

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

The new SH200 MCBs can be used in domestic, commercial and industrial applications for protection against over-current and short circuit.

3 - Protection components Motor circuit-breakers

K50H004UP cam changeover switch - 4-pole A - screw mounting

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

Electronic Circuit Breaker ESS20-0..

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

and other modular devices for low voltage installation

Manual Motor Starters. Meta-MEC

Bulletin 1489 Circuit Breakers. Selection Guide

Thermal-Magnetic Circuit Breaker 201/-WA

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Thermal Circuit Breaker 3120-F...

Control Circuit Protection

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

1489-M Circuit Breakers

Breaking and protection devices

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

Transcription:

87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Direct current MCB DX 3 16kA, up to 63 A (1 module per pole) CONTENTS PAGE 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection... 1 5. General Characteristics... 2 6. Compliance... 5 7. Auxiliaries and accessories... 6 1. DESCRIPTION - USE. Thermo-magnetic circuit breaker (MCB) for control, disconnection and protection of electrical circuits supplied in DC current, against overcurrents Symbol: 3. OVERALL DIMENSIONS Technology:. Current limiting circuit-breaker. 1 module per pole. Each pole is 17,7 mm width 2. RANGE Polarity:. 2P. Rated currents, In:. 0,5 / 1 / 1,6 / 2 / 3 / 4 / 6 / 8 / 10 / 16 / 20 / 25 / 32 / 40 / 50 / 63A. Tripping characteristics and magnetic tripping calibrations:. Curve C (between 5 to 7 In). Thermal threshold:. Non operating current (Inf): 1,05 In.. Operating current (If): 1,3 In. Rated Voltage:. 230Vd.c. (direct current). Breaking capacity:. 10 ka at 440Vd.c.(direct current) according to IEC/EN60947-2.. 16 ka at 230Vd.c.(direct current) according to IEC/EN60947-2. X 2P 35.4mm 4. PREPARATION - CONNECTION Fixing:. On symmetric rail EN/IEC 60715 or DIN 35. Operating positions:. Vertical Horizontal Upside down On the side 1/6

4. PREPARATION CONNECTION (continued): Power supply:. Only from the top how is shown in the wiring diagram on left side of the device. 5. GENERAL CHARACTERISTICS: Front side marking:. By permanent ink pad printing showing: - Trade name: DX 3 - Breaking curve - Rated current (in A) - Icu in ka extreme breaking capacity according to IEC/EN 60947-2 - Rated voltage - Legrand reference code and Logo. - Mark: Legrand. Connection: The location of the terminals allows supplying by traditional HX 3 pin busbar. Terminal depth :. 14 mm Stripping length recommended:. 11 mm Screw head:. Mixed, slotted and Pozidriv 2. Recommended tightening torque:. Recommended: 2.5 Nm.. Mini : 2 Nm. Maxi : 3 Nm. Tools required:. For the terminals: Pozidriv n 2 or flat screwdriver 5,5 mm (6 mm maximum).. For fixing: flat screwdriver 5,5 mm (6 mm maximum). Connectable section: Copper cables Without ferrule With ferrule Rigid cable 1 x 1,5 mm² to 35 mm² 2 x 1,5 mm² to 16 mm² - Left side marking: Marquage face latérale :. By permanent ink pad printing: - wiring diagram. Flexible cable 1 x 1,5 mm² to 25 mm² 2 x 1,5 mm² to 10 mm² 1 x 1,5 mm² ² to 25 mm² Manual actuation of the MCB:. Ergonomic 2-position handle. "O-OFF": Device open. "I-ON": Device closed Contact status display:. By marking of the handle: O-Off white on a green background = contacts opened. I-On white on a red background = contacts closed. Sealing:. Possible in ʺOpenʺ position (OFF) or ʺCloseʺ position (ON). Locking ing:. By 5 mm padlock (cat. N 4 063 13) or 6 mm padlock (cat. N 227 97) with padlock support (cat. N 044 42) in Open position (OFF). 2/6

5. GENERAL CHARACTERISTICS (continued): Short-circuit breaking capacity:. Direct Current according to: IEC 60947-2 Un 2P 230 V 16 ka 440 V Icu 10 ka 500 V 6 ka Minimum operating voltage:. 12 V d.c. per pole. Pulse rated voltage:. Uimp = 4 kv Insulation rated voltage:. Ui = 500 V Pollution degree :. 2 according IEC/EN 60898-1. Electric strength:. 2500 V Load to close and to open of a pole trough the handle:. 0,5 Nm per pole to close.. 0,3 Nm per pole to open. Mechanical endurance:. 20000 operations without load.. 2000 operations under In, DC current. Enclosure material:. Polyester.. Characteristics of this material: self extinguishing, heat and fire resistant according to EN 60898-1, glow-wire test at 960 C for external parts made of insulating material necessary to retain in position current-carrying parts and parts of protective circuit (650 C for all other external parts made of insulating material). 5. GENERAL CHARACTERISTICS (continued): Protection class:. Protection index of terminals against solid and liquid bodies: IP 20 (according to IEC 529, EN 60529 et NF C 20-010).. Protection index of the box against solid and liquid bodies: IP 40 (according to IEC 529, EN 60529 et NF C 20-010).. Protection index against mechanical shocks: IK 02 (according to EN 50102 et NF C 20-015). Sinusoidal vibration resistance in accordance with IEC 60068.2.6:. According to IEC 60068-2-6.. Axis : x, y, z.. Frequency range: 5 100 Hz ; duration 90 minutes. Displacement (5 13,2 Hz) : 1mm. Acceleration (13,2 100 Hz) : 0,7g (g=9,81 m/s 2 ) Recognition:. Recognition of the circuits by label in the "label holder" on the frontside of m.c.b. Power dissipated per pole (W) :. Circuit breakers curve C In 0,5A 1A 2A 3A 4A 6A 10A 2P 1,4 2,1 2,1 2,4 2,5 1,1 1,1 In 16A 20A 25A 32A 40A 50A 63A 2P 1,5 1,7 2,4 3,1 4 6 5,5. Impedance per pole (Ω) = P dissipated In 2 Average weight per pole:. 0,150 kg. Volume when packed: Volume (dm³) Double pole 0,334 Ambient operating temperature:. Min. = -25 C. Max. = +60 C Ambient storage temperature:. Min. = -40 C. Max. = +60 C 3/6

5.. GENERAL CHARACTERISTICS (continued): Derating of circuit-breakers according to ambient temperature :. The nominal characteristics of a circuit breaker are modified according to the ambient temperature inside the cabinet or the enclosure where the circuit breaker is located.. Reference temperature: 40 C according IEC/EN 60947-2 Ambient temperature / In In (A) - 25 C - 10 C 0 C 10 C 20 C 30 C 40 C 50 C 60 C 70 C 0.5 0.64 0.62 0.6 0.57 0.55 0.52 0.5 0.47 0.42 0.40 1 1.6 1.5 1.4 1.3 1.2 1.1 1 0.9 0.8 0.7 1.5 2.0 1.9 1.8 1.7 1.7 1.6 1.5 1.5 1.4 1.4 2 3.0 2.8 2.6 2.5 2.3 2.2 2 2 1.9 1.8 3 4.1 3.8 3.6 3.5 3.3 3.2 3.0 2.9 2.8 2.7 3.5 4.9 4.5 4.2 4.0 3.9 3.7 3.5 3.4 3.3 3.2 5 7.0 6.4 6.0 5.8 5.5 5.3 5.0 4.8 4.7 4.5 6 8.2 7.5 7.0 6.6 6.4 6.2 6.0 5.8 5.6 5.4 10 14.0 12.5 11.5 11.1 10.7 10.3 10.0 9.7 9.3 9.0 16 21.9 20.0 18.7 18.0 17.3 16.6 16.0 15.4 14.7 14.1 20 27.7 25.0 23.2 22.4 21.6 20.8 20.0 19.2 18.4 17.6 25 34.5 31.5 29.5 28.3 27.2 26.0 25.0 24.0 22.7 21.7 32 45.8 41.0 37.8 36.5 34.9 33.3 32.0 30.7 29.1 27.8 40 55.5 51.0 48.0 46.0 44.0 42.0 40.0 38.0 36.0 34.0 50 70.0 64.0 60.0 57.5 55.0 52.5 50.0 47.5 45.0 42.5 63 88.1 80.6 75.6 72.5 69.9 66.1 63.0 59.8 56.1 52.9 Influence of the altitude: 2000 m 3000 m 4000 m 5000 m Dielectric holding 3000 V 2500 V 2000 V 1500 V Max operational Voltage 400V 400 V 400 V 400 V Derating at 30 C Derating of MCBs s function of the number of devices side by side: When several MCBs are juxtaposed and operate simultaneously, the thermal evacuation of the poles is limited. This results in an increase in operating temperature of the circuit breakers which can cause unwanted tripping. It is recommended to apply the following coefficients to the rated currents. Number of circuit breakers side by side Coefficient 2-3 0.9 4 5 0.8 6-9 0.7 10 0.6 These values are given by the recommendation of IEC 60439-1, NF C 63421 and EN 60439-1 standards. To avoid to have to use these coefficients, it is necessary to allow a good ventilation and to separate the devices with 0.5 module spacing elements (cat. N 4 063 07). 4/6

6. CONFORMITIES AND APPROVALS In accordance with standards:. IEC/EN 61009-1 with 10000A breaking capacity. IEC/EN 60947-2 with 16 ka breaking capacity. CEE guidelines : 73/23/CEE + 93/68/CEE. Legrand circuit-breakers can be used under the conditions of use as defined by IEC /EN 60947.. The performance of circuit breakers can be influenced by particular climates: hot dry, cold dry, hot humid, salt fog atmosphere Classification according to Annex Q (standard IEC/EN 60947-1) :. Category C with a range test temperature -25 C / +70 C. salt fog atmosphere according to standard IEC 60068-2-52 Environment respect Compliance with CEE directives:. Compliance with Directive 2002/95/EC of 27/01/03 called "RoHS" which provides for the banning of hazardous substances such as lead, mercury, cadmium, hexavalent chromium, brominated flame retardants polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) from 1 st July 2006. Compliance with Directive 91/338/CEE of 18/06/91 and Decree 94-647 of 27/07/04 Plastic materials :. Halogens-free plastic materials.. Marking of parts according to ISO 11469 and ISO 1043. Packaging:. Design and manufacture of packaging in accordance with Decree 98-638 of 07.20.98 and Directive 94/62/EC Approvals obtained:. France : NF for ratings up to 32A including.. Certification LOVAG for ratings up to 32A including. 5/6

Cat N (s) : 4 0950 59 à 4 095 74 7.. AUXILIARIES AND ACCESSORIES Wiring accessories:. Pin busbar HX 3 traditional.. Sealable screw cover (cat n 4 063 04).. Insulating shields (cat n 4 063 05). Dispatcher row HX 3. Signal auxiliaries:. Auxiliary contact (½ module cat n 4 062 58).. Fault signalling changeover switch (½ module cat n 4 062 60).. Auxiliary contact modifiable in default signal (½ module cat n 4 062 62).. Auxiliary contact + fault signalling switch - can be modified to 2 auxiliary contacts (1 module - cat n 4 062 66). Control auxiliaries:. Shunt releases (1 module - cat n.4 062 76 / 78).. Under voltage release (1 module - cat n 4 062 80 / 82).. Autonomous shunt trip for NC push-button (1 module - cat n. 4 062 84). Motor driven control modules. Motor driven control module (1 module cat n 4 062 91). Motor driven control module with automatic resetting integrated (2 modules cat n 4 062 93 / 95) Possible combinations of m.c.b and auxiliaries:. Auxiliaries are clipped on the left of the m.c.b.. Maximum number of auxiliaries for one circuit-breaker: 3.. Two signalling auxiliaries max. (cat. n 4 062 58 / 60 / 62 / 66).. Only one control auxiliary (cat. n 4 062 76 / 78 / 80 / 82 / 84).. One remote control or Stop & Go motor driven remote control. If signalling and control auxiliaries are associated on the same circuit breaker, the command auxiliary must be placed to the left of the signal auxiliary (ref. 4 062 5x / 6x). Sealing:. Possible in ʺOpenʺ position (OFF) or ʺCloseʺ position (ON). Lockout:. By 5 mm padlock (cat. N 4 063 13) or 6 mm padlock (cat. N 0 227 97) with padlock support (cat. N 4 063 03) in Open position (OFF). Installation software:. XL PRO 3 6/6