CERTIFICATE Solar Keymark Certificate No. SP SC0895-2 Holder/Issued to/manufacturer : Jiangsu Micoe Solar Energy Co. Ltd Address: NingHai Industrial Zone, Lianyungang City, Jiangsu Province, China Product name and description Solar thermal systems for water heating. For technical information see Appendix (2 pages). Models: Certificate The product is found to comply with the requirements in EN 2976-:2006 Factory made systems, Part : General requirements and the Specific CEN Keymark Scheme Rules for Solar Thermal Products, and are based on test results according to EN 2976-2:2006 Part 2: s. Marking Products conforming to this certificate shall be marked in accordance with the requirements in the Specific CEN Keymark Scheme Rules for Solar Thermal Products. The marking shall, together with the Keymark logo, show the identification code of the empowered certification body (SP Technical Research Institute of Sweden, No. 02), also see CEN-CENELEC Internal Regulations Part 4 Certification, Annex A. Validity This certificate is valid until 2022-04-9 provided that the conditions in the Solar Keymark Rules are fulfilled and the standard or rules are not modified significantly. The validity of the certificate can be checked in the database, see Solar Keymark website http://www.solarkeymark.org. Miscellaneous The manufacturer's factory production control procedures are under surveillance by the responsibility of SP. This certificate was first issued 202-04-9. This is issue number 2. Borås, Sweden 207-05-9 SP Technical Research Institute of Sweden Certification Lennart Aronsson Certification Manager Magnus Sturesson Certification Officer SP Technical Research Institute of Sweden Box 857, SE-50 5 Borås, Sweden Phone: +46 0-56 50 00 E-mail/internet: info@sp.se/www.sp.se 02 Empowered Certification Body No. 02: SP Certification, Sweden For more information of Solar Keymark visit: www.solarkeymar.org This certificate may not be reproduced other than in full, except with the prior written approval by SP. SP Certification rules SPCR402 applies.
Page of 5 Summary of EN2976-2 SOLAR SYSTEM test results Annex to Solar KEYMARK Certificate Brand (optional) Jiangsu Micoe Solar Energy Co., Ltd. Micoe Street NingHai Industrial Zone Postal Code 222000 Lianyungang city, Jiangsu Province System classification Application(s) Hot water Solar loop, circulation principle Thermosyphon Direct solar loop / heat exchanger Heat exchanger Open, vented or closed solar loop Vented Drain back/down Always filled (no drain) Store location Outdoor Store orientation (of main axis) Horizontal Type of auxiliary heating (internal back-up heat) Electric If other auxiliary/internal back-up heating, please specifiy: None Solar+supplementary OR Solar-only / Solar pre-heat Solar only / Solar preheat Collector(s) Jiangsu Micoe Solar Energy Co., Keymark lic.no. if available None Per module Area (AG) length m² mm width mm,53 735 305 2,34 735 702 2,74 735 2006 3,3 735 2545 Keymark lic.no. if available Store name 50L 200L 240L 300L Licence Number Issued Total nominal volume Heat store(s) Jiangsu Micoe Solar Energy Co., Ltd. None height width depth SP SC0895-2 207-05-9 Country E-mail China http://en.micoe.com info@micoe.com Tel. / Fax +86 58-8595-9567/9565 Auxiliary heated volume Electrical aux. heating power litres mm mm mm litres kw 50 200 435 800 optional optional,5,5 240 280 optional,5 300 2680 optional,5 Solar loop controller Solar loop fluid Keymark lic.no. if available None Recommended/required No recommend./requirements None NA Name None Name NA Solar loop pump - power range 0 W to 0 W Freezing point -20 C Number of collectors in each configuration for each store Store name 7022833GZU-00/002/003/004/005 Date of test report 207.4.25 The "negative pressure test of the collector" according to EN2975-2:2006, 5.9.2 was SP Technical Research Institute of Sweden Box 857, 50 5 Borås, Sweden www.sp.se info@sp.se tel +460 56 5000 Version 3.6, 204-06-8
Page 2 of 5 Summary of EN2976-2 test results Certification No. SP SC0895-2 Annex to Solar KEYMARK Certificate Issued 207-05-9 Jiangsu Micoe Solar Energy Co., Ltd. Country China Brand (optional) Micoe http://en.micoe.com Street NingHai Industrial Zone E-mail info@micoe.com Postal Code 222000 Lianyungang city, Jiangsu Province Tel. / Fax +86 58-8595-9567/9565 50L 200L 240L 300L No. Collectors Storage name 50L Daily drawoff 0 l Daily drawoff 40 l Daily drawoff 70 l Stockholm SE 624 92 0 3,2 7796 2355 0 30,2 9467 2668 0 28,2 WürzburgDE 5875 2022 0 34,4 7476 2467 0 Davos CH 6646 2808 0 42,3 8458 3368 0 39,8 027 3864 0 37,6 Athens GR 4565 2793 0 6,2 580 3488 33,0 9077 289 0 3, 0 60,0 7055 40 0 58, MJ/y Not relevant for solar domestic hot water system G 57 230 684 736 Ref. conditions Ta,ave 7,5 9,0 3,2 8,5 Tc,ave 8,5 0,0 5,4 7,8 Max. operating press. - collector side 0 kpa Max. operating press. - tank side 400 Date of test report 7022833GZU-00/002/003/004/005 207.4.25 The "negative pressure test of the collector" according to EN2975-2:2006, 5.9.2 was kpa All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 5 % Version 3.6, 204-06-8 SP Technical Research Institute of Sweden Box 857, 50 5 Borås, Sweden www.sp.se info@sp.se tel +460 56 5000
Page 3 of 5 Summary of EN2976-2 test results Certification No. SP SC0895-2 Annex to Solar KEYMARK Certificate Issued 207-05-9 Jiangsu Micoe Solar Energy Co., Ltd. Country China Brand (optional) Micoe http://en.micoe.com Street NingHai Industrial Zone E-mail info@micoe.com Postal Code 222000 Lianyungang city, Jiangsu Province Tel. / Fax +86 58-8595-9567/9565 No. Collectors Storage name 200L Daily drawoff 70 l Daily drawoff 200 l Daily drawoff 250 l Stockholm SE 9467 355 0 37, 37 397 0 35,7 3922 4344 0 3,2 WürzburgDE 9077 3649 0 40,2 0680 479 Davos CH 027 557 0 50,2 Athens GR 7055 4685 0 66,4 8300 5426 0 39, 3350 4595 0 34,4 2083 5804 0 48,0 504 6327 0 4,9 0 65,4 0374 6363 0 6,3 MJ/y Not relevant for solar domestic hot water system G 57 230 684 736 Ref. conditions Ta,ave 7,5 9,0 3,2 8,5 Tc,ave 8,5 0,0 5,4 7,8 Max. operating press. - collector side 0 kpa Max. operating press. - tank side 400 kpa 7022833GZU-00/002/003/004/005 Date of test report 207.4.25 The "negative pressure test of the collector" according to EN2975-2:2006, 5.9.2 was All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 5 % Version 3.6, 204-06-8 SP Technical Research Institute of Sweden Box 857, 50 5 Borås, Sweden www.sp.se info@sp.se tel +460 56 5000
Page 4 of 5 Summary of EN2976-2 test results Certification No. SP SC0895-2 Annex to Solar KEYMARK Certificate Issued 207-05-9 Jiangsu Micoe Solar Energy Co., Ltd. Country China Brand (optional) Micoe http://en.micoe.com Street NingHai Industrial Zone E-mail info@micoe.com Postal Code 222000 Lianyungang city, Jiangsu Province Tel. / Fax +86 58-8595-9567/9565 No. Collectors Storage name 240L Daily drawoff 200 l Daily drawoff 250 l Daily drawoff 300 l Stockholm SE 37 3927 0 35,3 3922 4540 0 32,6 6706 5048 0 30,2 WürzburgDE 0680 4064 0 38, 3350 4804 0 36,0 6020 5339 0 33,3 Davos CH 2083 5880 0 48,7 504 6787 0 44,9 825 7524 0 4,5 0 63, 2449 7552 0 60,7 Athens GR 8300 5452 0 65,7 0374 6546 MJ/y Not relevant for solar domestic hot water system G 57 230 684 736 Ref. conditions Ta,ave 7,5 9,0 3,2 8,5 Tc,ave 8,5 0,0 5,4 7,8 Max. operating press. - collector side 0 kpa Max. operating press. - tank side 400 kpa 7022833GZU-00/002/003/004/005 Date of test report 207.4.25 The "negative pressure test of the collector" according to EN2975-2:2006, 5.9.2 was All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 5 % Version 3.6, 204-06-8 SP Technical Research Institute of Sweden Box 857, 50 5 Borås, Sweden www.sp.se info@sp.se tel +460 56 5000
Page 5 of 5 Summary of EN2976-2 test results Certification No. SP SC0895-2 Annex to Solar KEYMARK Certificate Issued 207-05-9 Jiangsu Micoe Solar Energy Co., Ltd. Country China Brand (optional) Micoe http://en.micoe.com Street NingHai Industrial Zone E-mail info@micoe.com Postal Code 222000 Lianyungang city, Jiangsu Province Tel. / Fax +86 58-8595-9567/9565 No. Collectors Storage name 300L Daily drawoff 250 l Daily drawoff 300 l Daily drawoff 400 l Stockholm SE 3922 4897 0 35,2 6706 5753 0 34,4 22275 673 0 30,2 WürzburgDE 3350 505 0 38,2 6020 6027 Davos CH 504 7480 0 49,5 Athens GR 0374 683 0 65,7 2450 802 0 37,6 2360 746 0 33,5 825 8688 0 47,9 2467 0020 0 4,5 0 65, 6599 0044 0 60,5 MJ/y Not relevant for solar domestic hot water system G 57 230 684 736 Ref. conditions Ta,ave 7,5 9,0 3,2 8,5 Tc,ave 8,5 0,0 5,4 7,8 Max. operating press. - collector side 0 kpa Max. operating press. - tank side 400 kpa 7022833GZU-00/002/003/004/005 Date of test report 207.4.25 The "negative pressure test of the collector" according to EN2975-2:2006, 5.9.2 was All values are subject to some uncertainty; e.g. the uncertainty on system output is typically in the range of ± 5 % to ± 5 % Version 3.6, 204-06-8 SP Technical Research Institute of Sweden Box 857, 50 5 Borås, Sweden www.sp.se info@sp.se tel +460 56 5000