Home distribution board DIDO-E

Similar documents
Surface mounted distribution board - white door

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Fuse switch disconnectors

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on right side

DESIGN IN FUNCTION OF SAFETY

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Empty enclosures IEC 62208

DX³ RCCBs - ID 4P up to 100 A

IP65 Wall mounted distribution boards ECH

TX³ RCCBs 2P up to 100 A

Busbars for CBI 13 mm Q-range MCB

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

RX 3 M.C.B A up to 63 A

up to 63 A (1 module per pole)

RX 3 M.C.B A up to 63 A

DX³ 4-pole RCBO 6000 A/10 ka

ENYSTAR Load Centers up to 250 A

(1,5 modules per pole)

Distribution Blocks & Bus-bar Solutions

Electronic Circuit Breaker ESS20

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products

R.C.B.O. SP / 1 module

14853 E. Hinsdale Ave. Centennial, CO USA Toll Free: / FAX:

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Spacial SF for Prisma Plus P system

XL³ 400 metal distribution cabinets, free-standing enclosures and cable compartments

MR - MEDIUM RATING A

BUSBAR TRUNKING SYSTEMS a

workshop specifications Plexo³ IP 65 cabinets

67 IB INTERLOCKED SOCKET-OUTLET IEC 309 STANDARDS

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Viking 3 - Screw connection Disconnect terminal blocks

Technical data: Maximum insulation voltage: 690V; 50Hz Flame retardance: V-0 IP code: IP40 Colour: Gray Mounting type: Surface and flush

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Combiester Switch Disconnectors Airco Switches Railbox Fuse Switch Disconnectors Orion Minipol Maxipol

DX³ RCBO 6000 A Phase + Neutral, neutral right side

Enclosures. flush-mounted/ /wall-mounted. PE, N, from 28 modules N for RCCB. PE, N, N for RCCBs. Part of standard supply

Electronic Circuit Breaker ESS20-0..

Thermal-Magnetic Circuit Breaker 201/-WA

CS Wall-Mounted Sheet Steel Enclosures with Mounting Plate

LB - LIGHTING BUSWAY 25-40A

Pre wired limit switches

APO ENCLOSURES. The bases are made of grey (RAL 7036), hot moulded glass fibre reinforced polyester

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS General Information Extended Product Type: MS

Busbar Systems Accessories

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

1SLC004001B0202. Enclosures and cable systems overview

Contents Technical characteristics Han A Technical characteristics Han 3 A with HARAX Termination

One Source. Fuse monitoring for NH Fuse-Bases or Fuse-Rails

KAM A Lighting Busbar System KAP A Plug-in Busbar Distribution System

DX³ RCBO 6000A Phase + Neutral, neutral on left

GE Industrial Solutions. New. QuiXtra 4000ED.02. Low Voltage Distribution Boards up to 4000A. GE imagination at work

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

ACCESS SOLUTIONS NEW PRODUCTS BROCHURE.

Contents Technical characteristics Han A Technical characteristics Han 3 A with HARAX Termination

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

13.1. Range of Enclosures. KRONECTION Box A 2 for up to 2 pairs. Expert Knowledge. Short survey of the KRONECTION Box A 2 for up to 2 pairs

Electrical installation solutions for buildings Technical details Automation boards

ype UP T Busplugs Low Voltage Switchboard Equipment

Fuse switch disconnectors

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Datasheet. System pitch mm (0.400 inch) - SU/BU BUZ 10.16HP/02/180F AG BK BX

4 pole insulated conductor rails ULA 35A, 50A, 80A, 100A

MOULDED CASE CIRCUIT BREAKERS BC160N

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Low Voltage Main Distribution Board

12 Page. tehalit.ba7a wide-slot wiring duct tehalit.ba7b narrow-slot wiring duct tehalit.b7a solid duct 12.12

vertical fuse switch disconnectors

EWC-PC POWER CENTER FOR LOW VOLTAGE POWER DISTRIBUTION UP TO 6300A POWER CENTER

D509E. Manual Motor - Starters

Switches with manual reset

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Plexo 3 weatherproof cabinets

MBS AG. CTB Plug-in current transformer MBS AG. Dimensions: General technical specifications:

FOOT SWITCHES

Motorized switch-disconnectors OTM 40 to 125 Amperes

SENTRON Switching and Protection Devices Switch Disconnectors

General notes. Operating conditions

PLASTIC BOXES - WIRE DUCTS - DIN RAILS - CABLE TIES

ROC. IP66 Polyester Double Isolation Boxes. Certificaciones. Technical features

Low Voltage Switches. Switches Motorized change-over switches OTM _C

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

ZP2.5-PE Spring Terminal Block Ground

Kaedra Weatherproof DIN Type Enclosures

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Han-Power Energy Bus Components

3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR

Transcription:

Home distribution board DIDO-E Degree of protection Colour Double insulation Standard Installation temperature *IP 30 for EC 1+1, 3+1, 3+2 IP 40* white IEC60670-24 -25 / +60 C Number of N - PE terminals: ECT/M8PT/PO 2x8..8 PE / 8 N ECT/M12PT/PO 2x10 10 PE / 10 N ECT/M18PT/PO 2x13 13 PE / 13 N ECT/M24PT/PO 2x13 13 PE / 13 N ECT/M36PT/PO 2x15 15 PE / 15 N ECT48PT/PO 2x20 20 PE / 20 N ECT/M 2x18PT/PO 2x15 15 PE / 15 N ECT/M 3x18PT/PO 2x25 25 PE / 25 N ECG14 2x10 10 PE / 10 N ECG28 2x13 13 PE / 13 N ECG42 2x15 15 PE / 15 N ECG56 2x20 20 PE / 20 N EC 1+1 - EC 3+1 - EC 3+2 2x4 4 PE / 4 N - ECG14, ECG28, ECG42 have 1 additional free space to build in an extra PST-UNI terminal. - ECG56 has 3 additional free spaces to build in up to 3 extra PST-UNI terminals. - Double insulation not valid for ECG MEDI Surface mounted distribution board Max. allowed power losses when Max. number type Dimensions of devices are installed B C D E Pde ECT8PT/ECT8PO 236 mm 215 mm 112 mm 107 mm 108 mm 14W ECT12PT/ECT12PO 236 mm 287 mm 112 mm 107 mm 180 mm 22W ECT18PT/ECT18PT 236 mm 396 mm 112 mm 107 mm 289 mm 22W ECT24PT/ECT24PO 361 mm 287 mm 112 mm 232 mm 180 mm 24W ECT36PT/ECT36PO 482 mm 287 mm 112 mm 357 mm 180 mm 26W ECT48PT/ECT48PO 652 mm 287 mm 112 mm 357 mm 180 mm 28W ECT2x18PT/ECT2x18PO 361 mm 396 mm 112 mm 232 mm 289 mm 26W ECT3x18PT/ECT3x18PO 526 mm 396 mm 112 mm 357 mm 289 mm 26W Flush mounted distribution board Max. allowed power losses when Max. number type Dimensions of devices are installed B C D E F G Pde ECM8PT/ECM8PO 212 mm 201 mm 68 mm - 211 mm 232 mm 99 mm 14W ECM12PT/ECM12PO 212 mm 273 mm 68 mm - 283 mm 232 mm 106 mm 22W ECM18PT/ECM18PO 212 mm 373 mm 68 mm - 392 mm 232 mm 106 mm 22W ECM24PT/ECM24PO 336 mm 273 mm 68 mm 125 mm 283 mm 357 mm 106 mm 24W ECM36PT/ECM36PO 460 mm 273 mm 68 mm 125 mm 283 mm 482 mm 106 mm 26W ECM2x18PT/ECM2x18PO 336 mm 373 mm 68 mm 125 mm 392 mm 357 mm 106 mm 26W ECM3x18PT/ECM3x18PO 502 mm 373 mm 68 mm 125 mm 392 mm 522 mm 106 mm 26W 673

Flush mounted distribution board - metal door Max. allowed power losses when Max. number type Dimensions of devices are installed B C D E F G Pde ECG14 274 mm 306 mm 56 mm 33 mm 96 mm 317 mm 346 mm 31W ECG28 399 mm 306 mm 56 mm 33 mm 96 mm 442 mm 346 mm 40W ECG42 549 mm 306 mm 56 mm 33 mm 96 mm 592 mm 346 mm 50W ECG56 673 mm 306 mm 56 mm 33 mm 96 mm 717 mm 346 mm 60W F D B C G E Surface mounted distribution board - IP30 type Dimensions Number of modules EC 1+1 137 x 51 x 57 1 (+1) EC 3+1 137 x 87 x 57 3 (+1) EC 3+2 97 x 155 x 57 3 (+2) ECG ECG_H Material crylonitrile butadiene styrene Material crylonitrile butadiene styrene Color Door RL9003 crylonitrile butadiene styrene Color Door RL9003 Metal Color Glow wire test Terminal holder Transparent & white 650 C Self extinguish material Color Glow wire test Terminal holder white 850 C Self extinguish material Glow wire test Temperature Rated voltage Standard Halogen free 960 C -25 C... +60 C C400V IEC60670 Glow wire test Temperature Rated voltage Standard Halogen free 960 C -25 C... +60 C C400V IEC60670 674

dvantages Easy terminal mounting Left or right door mounting Easy cover and door mounting Holders for secure hollow wall installation Installation marking slots for hollow walls 675

Home distribution boards DIDO-ECH Dimensions Degree of protection Insulation class Colour Double insulation IP 65 II RL 7035 Standard Installation temperature IEC60670-24 -20 / +60 C Number of PE - N terminals: 4-G 2x4 4 PE / 4 N 8-G 2x8 8PE / 10 N 12-PT 2x10 10 PE / 10 N 24-PT 2x15 15 PE / 15 N 36-PT 2x15 15 PE / 15 N 676 type ECH-4G ECH-8G ECH-12PT ECH-24PT ECH-36PT Max. allowed power losses when Max. number of devices are installed Dimensions 201 mm 201 mm 259 mm 384 mm 508 mm B 128 mm 202 mm 319 mm 319 mm 319 mm C 120 mm 120 mm 144 mm 144 mm 144 mm D 125 mm 125 mm E 78 mm 100 mm 210 mm 210 mm 210 mm F 111 mm 140 mm 130 mm 255 mm 380 mm Pde 10W 13W 16W 24W 26W

Metal enclosures GT type, IP65 Compliance with standards and directives: EN 62208 Empty enclosures for low voltage switchgear and controlgear EN 60529 Degrees of protection provided by enclosures (IP Code) EN 62262 Degrees of protection against external mechanical impacts provided by enclosures of electrical equipment (IK code) Meet the requirements of the RoHS Directive Marked CE The enclosures are supplied with: - Cable entry cover with mounting kit - Mounting plate with mounting kit - Door lock with, double-bit insert and key - Cover holes - Earthing set of grounding (without cable) Symbols: GT 100-80-30 Height Width Depth 677

Type Height Y (mm) Width X (mm) Depth Z (mm) Lock quantity Hinges quantity Cable entry depth B1 (mm) Cable entry width 1 (mm) Cover cable entry depth B (mm) Cover cable entry width (mm) GT 25-20-15 250 200 150 1 2 70 140 110 180 GT 30-20-15 300 200 150 1 2 70 140 110 180 GT 30-30-15 300 300 150 1 2 70 240 110 280 GT 30-30-20 300 300 200 1 2 120 240 160 280 GT 30-30-25 300 300 250 1 2 170 240 210 280 GT 40-30-15 400 300 150 1 2 70 240 110 280 GT 40-30-20 400 300 200 1 2 120 240 160 280 GT 40-30-25 400 300 250 1 2 170 240 210 280 GT 40-40-15 400 400 150 1 2 70 340 110 380 GT 40-40-20 400 400 200 1 2 120 340 160 380 GT 40-40-25 400 400 250 1 2 170 340 210 380 GT 40-60-20 400 600 200 1 2 120 540 160 580 GT 40-60-25 400 600 250 1 2 170 540 210 580 GT 40-60-30 400 600 300 1 2 170 540 210 580 GT 50-40-15 500 400 150 2 2 70 340 110 380 GT 50-40-20 500 400 200 2 2 120 340 160 380 GT 50-40-25 500 400 250 2 2 170 340 210 380 GT 50-55-20 500 550 200 2 2 120 490 160 530 GT 50-55-25 500 550 250 2 2 170 490 210 530 GT 60-40-15 600 400 150 2 2 70 340 110 380 GT 60-40-20 600 400 200 2 2 120 340 160 380 GT 60-40-25 600 400 250 2 2 170 340 210 380 GT 60-60-20 600 600 200 2 2 120 540 160 580 GT 60-60-25 600 600 250 2 2 170 540 210 580 GT 60-60-30 600 600 300 2 2 170 540 210 580 GT 60-80-30 600 800 300 2 2 170 740 210 780 GT 65-55-20 650 550 200 2 2 120 490 160 530 GT 65-55-25 650 550 250 2 2 170 490 210 530 GT 80-40-20 800 400 200 2 3 120 340 160 380 GT 80-40-25 800 400 250 2 3 170 340 210 380 GT 80-55-20 800 550 200 2 3 120 490 160 530 GT 80-55-25 800 550 250 2 3 170 490 210 530 GT 80-60-20 800 600 200 2 3 120 540 160 580 GT 80-60-25 800 600 250 2 3 170 540 210 580 GT 80-60-30 800 600 300 2 3 170 540 210 580 GT 80-60-40 800 600 400 2 3 170 540 210 580 GT 80-80-20 800 800 200 2 3 120 740 160 780 GT 80-80-25 800 800 250 2 3 170 740 210 780 GT 80-80-30 800 800 300 2 3 170 740 210 780 GT 80-80-40 800 800 400 2 3 170 740 210 780 GT 80-100-30 800 1000 300 2 3 170 940 210 980 GT 80-100-40 800 1000 400 2 3 170 940 210 980 GT 100-60-25 1000 600 250 3p* 3 170 540 210 580 GT 100-60-30 1000 600 300 3p* 3 170 540 210 580 GT 100-60-40 1000 600 400 3p* 3 170 540 210 580 GT 100-80-25 1000 800 250 3p* 3 170 740 210 780 GT 100-80-30 1000 800 300 3p* 3 170 740 210 780 GT 100-80-40 1000 800 400 3p* 3 170 740 210 780 GT 100-100-25 1000 1000 250 3p* 3 170 940 210 980 GT 100-100-30 1000 1000 300 3p* 3 170 940 210 980 GT 100-100-40 1000 1000 400 3p* 3 170 940 210 980 GT 120-60-25 1200 600 250 3p* 3 170 540 210 580 GT 120-80-25 1200 800 250 3p* 3 170 740 210 780 GT 120-80-30 1200 800 300 3p* 3 170 740 210 780 GT 120-80-40 1200 800 400 3p* 3 170 740 210 780 GT 120-100-30 1200 1000 300 3p* 3 170 940 210 980 GT 120-100-40 1200 1000 400 3p* 3 170 940 210 980 678

679

The door The cover of cable entry 680

The door Wall holder Mounting plate X-52 X-90 X-30 Y-64 Door driling B 681

SB (S Box) Double insulation enclosures IP66, IK10 IP protection degree IK protection degree Double insulation IP 66 IK10 ( 20 kj) Dimensions Insulation class Nominal voltage Nominal current Installation temperature II 1000V DC 1000-30 C... +60 C 170 161 154 Colour Base - grey (RL 7035) / Lid - transparent Flame resistance (UL 94) Base - V0 / Lid - V2 Thermal resistance Base - 960 C / Lid - 750 C Standard IEC 62208 35 Ø 8-8.5 35 200 270 35 110 180 35 SB-32 18 200 236 18 8.5 110 127 171 161 154 35 290 35 Ø 8-10 35 360 290 290 310 35 20 290 20 10 360 SB-44 330 B-B - 171 161 154 35 Ø 8 20 B 35 290 360 35 B 200 35 200 70 540 SB-64 9 290 308 20 200 70 200 510 9 682

Free-standing cable distribution cabinets Electrical parameters Rated operational voltage Un Rated insulation voltage Ui Flamability category Degree of protection against external mechanical impacts Protection degree Protection class Operating temparature 400V 690V V0 IK 10 IP44 ( IP54) II -25 C... 40 C Dimensions Obudowy OTD 00 Enclosures Enclosures OTD OTD 0 / 00 Gehäuse / Gehäuse OTD 0 OTD / Корпуса 00 / Корпуса OTD 0 OTD 00 Obudowy OTD 0 KVR 00 KVR 0 TYP Type / rt / Тип OTD 00 NR KTLOGOWY rt. no. 0105k04615 OTD OTD Enclosures OTD 2 / Gehäuse OTD 2 / Корпуса OTD 2 Obudowy OTD 2 Enclosures OTD 1 / Gehäuse OTD 1 / Корпуса OTD 1 Obudowy OTD 1 Enclosures OTD 2 / Gehäuse OTD 2 / Корпуса OTD 2 TYP Type / rt / Тип OTD 0 NR KTLOGOWY rt. no. 0105k04616 Obudowy OTD 2 KVR 1 KVR 2 233 OTD TYP Type / rt / Тип OTD 2 NR KTLOGOWY rt. no. 0105k04618 683

[mm] B C D KVR-P 00 460 408 360 332 KVR-P 0 595 543 495 467 KVR-P 1 790 738 690 662 KVR-P 2 1120 1068 1020 992 [mm] B C D KVR-PE 00 460 408 360 332 KVR-PE 0 595 543 495 467 KVR-PE 1 790 738 690 662 KVR-PE 2 1120 1068 1020 992 KVR-CB 00 KVR-CB 0 KVR-CB 1 [mm] B C KVR-MP 00 435-2 KVR-MP 0 572-2 KVR-MP 1 764 300 2 KVR-MP 2 1095 400 2 KVR-CB 2 684

KVR-I [mm] KVR-FB 00 450 KVR-FB 0 585 KVR-FB 1 784 KVR-FB 2 1110 KVR-OC 38 12-27 10,5 KVR-CH Enclosure ventilation 685

ccessories Terminal for protective conductors type length supply outlet [m] [mm 2 ] [mm 2 ] 2/6 0,056 2 x 22 6 x 14 2/8 0,086 2 x 22 8 x 14 2/12 0,092 2 x 22 12 x 14 2/18 0,128 2 x 22 18 x 14 Insulating terminal for protective conductors type length supply outlet [m] [mm 2 ] [mm 2 ] 2 x 2/6 0,265 4 x 22 12 x 14 2 x 2/8 0,265 4 x 22 16 x 14 2 x 2/12 0,265 4 x 22 24 x 14 2 x 2/18 0,265 4 x 22 36 x 14 - Section rails for ETIMT P10 Cross section 10 mm 2 16 mm 2 25 mm 2 Feeding at beginning/ending Max. current Is/Phase 63 80 100 Cross section of connection, mm2 10 16 25 Feeding in the middle Max. current Ie/Phase Cross section of connection, mm2 Heat deflection temperature PVC Comparative tracking index PVC Standards Climate stability 100 130 170 25 35 2x25 80 C flame resistant 300V EN 60947-1:2007/ IEC 60947-1:2007 DIN EN 60068 Insulation coordination Degree of pollution 2 Electrical data Impulse voltage strenght Min. air distance Min. creeping distance Max. operating voltage Protection class Short circuit rating Dielectric strenght Material 4,5 kv > 5,5 mm > 5 mm 690 V C/DC IP20 ICC 15k NH 250 gl 500V 32 kv/mm Material Surface Busbar Copper plain Insulation PVC lead-free grey RL 7035 Endcover moulded mpacity at 35 C ambient temperature depending of feeding point TTEN TION : To prevent electrical shock, disconnect from power source before installing or servicing. Danger Installation by electricians only 1. 2. 3. Cut Due to security purposes all shortened busbars need to be covered with suitable endcovers. Cut back copper 1. 3. 2. 4. 5. Burr Clean ttach end cover 6. 5. 3. 5. 2. 5. 1. 686

24,40 26,70 12,80 7,10 5,50 12,10 13,90 30,00 30,00 24,40 12,90 8,20 12,30 7,40 30,20 13,60 8,50 13,7 8 15,40 17,10 16,80 6 18 11 IZ16/2F/56 55x18=990 1,5 45 18 6 11 IZ16/2F/44 21x45=945 1,5 17,3 31 17,3 31 13.7 8 15,8 15,8 1012 +2 990 +2 IZ16/3F/57 56x18=1008 18 6 11 1,5 17,3 31 13,7 8 (17,3) 31 13,7 8 Dimensions IZ16/4F/56 55x18 = 990 6 18 11 1,5 15,8 21,3 +2 1010 1027 +2 17,90 17,90 17,80 17,80 11,70 6,00 11,60 6,00 IZ10/1F 16,40 IZ10/3F 17,80 17,80 17,80 17,80 11,80 6,00 11,60 6,00 5,10 IZ12/1F IZ12/3F 687

24,40 14,30 17,30 30,70 13,40 7,10 27,40 13,10 7,10 12,10 32,30 15,60 6,70 30,00 30,00 12,90 8,20 24,40 12,30 7,40 31,80 13,80 7,00 31,20 14,30 8,50 16,80 22,00 15,40 16,90 16,50 16,70 17,10 18,00 11,70 6,00 18,00 18,00 11,60 6,00 17,80 17,80 IZ16/1F IZ16/3F 5,50 11,60 6,00 18,00 18,00 11,60 6,00 18,00 18,00 18,00 11,00 IZ16/2F IZ16/4F 11,80 6,00 17,80 17,80 11,60 6,00 17,80 17,80 5,10 IZ12/1F IZ12/3F 10,00 5,00 15,00 15,00 IZ16_3F_12_STV IZM16/3F 688

(15,2) 28,5 (15,2) 28,5 13,3 13,3 27,30 27,00 12,50 5,80 5,40 14,30 14,50 29,80 13,00 12,80 12,00 13,30 25,60 12,30 11,50 16,80 17,00 IZ-S rails Nominal voltage Dielectric strength Insulating resistance Temperature range Glow wire test Self-extinguishing Standards max. 500V 2,5 kv > 5 MΩ (DIN 53482) -20 C... + 50 C 850 C (IEC 695-2-1) V-O EN 60947-7-1 cross section Rated current () 10 mm² 63 12 mm² 80 16 mm² 100 4,00 17,80 17,80 4,00 17,80 17,80 IZS10/1F 16,60 IZS10/3F 4,00 17,80 17,80 4,00 17,80 17,80 IZS16/1F IZS16/3F 9 3,2 23x9 = 207 9 3,2 23x9 = 207 9,1 1,3 9,2 1,3 216 + 2 11,4 216 + 2 11,4 SKN0021 SKN0029 689

(15,2) 27,5 (15,2) 27,5 12,3 12,3 18 18 9 6,1 4 (202,7) 9x18 =162 9 1,3 3x18=54 18 6,1 18 9 4 (238,6) 9x18= 162 9 1,3 10,7 10,7 216 + 2 252 + 2 SKN0032 SKN0034 3P Din rail distribution blocks EDB : Degree of protection Short circuit withstand capability I cc Rated current In accordance with IP20 (with closed cover) 20k 125 EN 60947-1, EN 60947-7-1 Wire cross section by terminal size Wire with ferrule Wire without ferrule Terminal size [mm] 1,5-6 mm 2 2,5-6 mm 2 Ø 5,3 6-16 mm 2 10-25 mm 2 Ø 7,5 10-16 mm 2 10-35 mm 2 Ø 9 690

METER board 100 B C D E F MPO 250 80 85 47 63 170 VPO 370 75 170 136 50 241 MP 250 80 85 47 63 270 VP 370 75 170 136 50 241 15 35 METER board type dimension C B D E F 200 Universal board covering UPO : Standard length of profile Number of carriers per 1 m of profile Distance between mounting rails Width of distance for built-in elements 1 m 4 pcs 125 mm 46 + 0,5 mm terminal plate flat profile corner profile 119,2 45,6 78 10 2 62,5 2,2 60,5 53,7 13 24 2 2 13 10 36,5 6,4 33,8 691

Installation channels 692