MODEL 1200S MAGNETIC LOCK

Similar documents
MODEL 1200S MAGNETIC LOCK

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

MODEL 600S 600 POUND SINGLE MAGNETIC LOCK SPECIFICATIONS

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

MODEL 1200LB 1200 POUND MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR

V2M1200/1290 Series Maglock Installation Instructions

INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK

1-3/4" MOUNTING INSTRUCTIONS: 1150 SERIES SURFACE MOUNTED 1500 LB. ELECTROMAGNETIC LOCK

M670/M680BD MAGNALOCK SERIES Installation Instructions

Installation Instructions for Slide Mount Magnetic Locks

INSTALLATION DESCRIPTION

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

Installation Instructions for ROFU Key Hole Mount Magnetic Locks

INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK

Security Door Controls

MODEL 3002xTJ32 ELECTROMAGNETIC LOCK INSTALLATION INSTRUCTIONS

MagForce+ The Positive Force in Electromagnetic Locks

EMLock 1500 Series. MEA Listed

Installation Instructions

With LED, Bond Sensor E-941SA-600PQ 600-lb. (272kg) E-941SA-1K2PQ 1200-lb. (545kg) Weatherproof E-941SA lb.

E-941SA-300RQ. Manual. 300-lb Single-Door Electromagnetic Lock with Reversible Magnet

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty.

INSTALLATION EML375. Pre-Installation Instructions. Electromagnetic Locks

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Instructions For PG-1200RC Magnetic Locking Devices

HANDLING MECHANICAL INSTALLATION

2965 Magnetic Shear Lock Installation Instructions

Pre-Installation Instructions

Package Contents. Mounting Hardware

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

INSTALLATION 8310/8320

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

LCN 9740 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

DynaLock 705 Emmett Street Bristol, CT Phone:(860) Fax:(860)

Electromagnetic Door Holder/Releases

9540 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

INSTALLATION INSTRUCTIONS MINI EXIT CHECK DELAYED EGRESS EMLOCK 1581S

Installation Instructions

MOUNTING INSTRUCTIONS FOR TJ1000 SERIES INSWINGING DOORS ******READ THOROUGHLY BEFORE INSTALLING******

MAGNALOCKS MAGNALOCKS. The Electromagnetic Lock System That Will Outlast Your Building

INSTALLATION AND OPERATING INSTRUCTIONS For Model M38 and M68 Magnalocks (Versions L, S and LS with D and T Options)

LCN 9540 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

280+ SHEARLOCK INSTALLATION AND WIRING MODELS: 280+ and 280+TRD TRD

7100SZ Series SafeZone Installation and Instruction Manual

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE ELECTROMAGNETIC LOCK.

9550 SERIES FEATURES OPERATOR MOUNTS SIMULTANEOUS PAIR, SURFACE MOUNT *PULL SIDE PUSH SIDE DOUBLE EGRESS

STANDARD / DOUBLE STANDARD MAGNETIC LOCK

Power Operators. Requirement. Approved Manufacturers. -All Operators To Be Electrically Powered -Operators To Be Aluminum (BHMA 689) Finish

Procedure Replacing a Cover

9530 Series Senior Swing. Features. Special Templates. Fasteners Mounting. Certifications

VM300 Series. Electromagnetic Lock BRACKETS SPECS VM300

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1

Alarm Controls Product Guide

M32 600lb Holding Force Magnalock

MAGNETIC LOCKS SERIES OPTIONS (ADD TO LOCK): xl. ADD 1 LED (BICOLOR RED / GREEN) xd. ADD SPDT DOOR POSITION SWITCH (SINGLE) x2d

Installation Instructions

SHEAR ALIGNING MAGNALOCK MODEL SAM2-24 INSTALLATION AND OPERATING INSTRUCTIONS

*PULL SIDE mount shown

LOCKNETICS MagForce+ Series. Locknetics MagForce Traffic Control Magnet MEA

51 Series Door Closers. An ASSA ABLOY Group brand

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

9550 SERIES FEATURES OPERATOR MOUNTS SIMULTANEOUS PAIR, SURFACE MOUNT *PULL SIDE PUSH SIDE DOUBLE EGRESS

Electromagnetic Lock Reference Chart

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

Alarm Controls Product Guide

INSTALLATION INSTRUCTIONS SHEAR LOCKING MAGNET 1561TJ MAX. HOLDING FORCE 2000 lbs.

Securitron M32, M62, M82 Magnalock. Accessories

Accessories 286 SDC SECURITY DOOR CONTROLS

9560 Series Senior Swing. Features. Special Templates. Cover Fasteners Mounting. Certifications

Excel Series Value Engineered Access Hardware

EMLock Magnetic Locks

Locking Devices. Electromagnetic Locks. Security Door Controls 8 SECURITY DOOR CONTROLS

9550 Series Senior Swing. Features. Special Templates. Certifications. Fasteners Mounting

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

5600 Series Power Operator Installation and Instruction Manual

EMLock Magnetic Locks

Vertical Housing EMLock Discount Code GK LIST. Retrofit Kit for Discontinued Locknetics 390+ PLUS

ME217PIB / ME503PIB SMART INTERLOCK TECHNOLOGY ACME ADAPTER INTERLOCK BRACKET INSTALLATION AND OPERATING INSTRUCTIONS

Concealed overhead closer for high-end applications DOOR CLOSERS CATALOG

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

ARCHITECTURAL DOOR HARDWARE DOOR STOPS & HOLDERS THRESHOLDS & GASKETING CATALOG

Magnalock Selection Guide

IK - Installation Kit. The complete IK and IK2 kits offer substantial savings over purchasing the same items separately

AL600ULX Series. Power Supply/Charger Installation Guide

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Legacy Installation Manual

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual

M32 Series - 600lb Holding Force Magnalock

1.0 Features and Description

LCN AUTOMATIC OPERATORS

ALARM CONTROLS CORPORATION MSRP PRICING 2014

MEP801PIK / MEP801PIKL / MEP801PIH / MEP801PIHL SMART INTERLOCK TECHNOLOGY HOSE END VALVE HOLSTER INSTALLATION AND OPERATING INSTRUCTIONS

*CENTER PIVOT arm shown

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

ASSA ABLOY MPI (Infinite Hold Open Range) Support Unit Models. Multi-Point Electromechanical Overhead Concealed Closer Holder Releasing Device

Securitron M32, M62, M82 Magnalock. Accessories

2904 Power Supply Installation Instructions I-EA00041

Transcription:

MODEL 1200S MAGNETIC LOCK SPECIFICATIONS U.L. LISTED, LISTING NUMBER R16759 1200 POUND MINIMUM HOLDING FORCE MAGNET SIZE 10-1/2 L x 2-7/8 H x1-1/2 W 12 OR 24 VOLT DC OPERATION, JUMPER SELECTABLE CURRENT DRAW 400 MA @ 12 VDC, 200 MA @ 24 VDC CAN BE USED WITH ANY ACCESS CONTROL SYSTEM ALL METAL NON-ALUMINUM PARTS ARE D CLEAR ANODIZED FINISH STANDARD DURONIC US 40 FINISH AVAILABLE DRESS-UP COVERS IN POLISHED CHROME AND BRASS ARE AVAILABLE LIFETIME WARRANTY ALARM CONTROLS CORPORATION 19 BRANDYWINE DRIVE P.O. BOX 280 DEER PARK, NY 11729 1 631 586-4220 1 800 645-5538 WWW.ALARMCONTROLS.COM EMAIL INFO@ALARMCONTROLS.COM

MAGNETIC LOCK INSTALLATION INSTRUCTIONS PLEASE READ BEFORE INSTALLATION ALARM CONTROLS CORPORATION OFFERS A COMPLETE LINE OF MAGNETIC LOCKS AND ACCESSORY ITEMS TO ASSIST THE INSTALLER IN MANAGING EVERY APPLICATION. THE MAGNETIC LOCK IS DESIGNED TO MOUNT TO THE FRAME ON THE STOP SIDE OF THE IN A TYPICAL OUTSWINGING INSTALLATION,(SEE PAGE 2 FOR INSWINGING INSTALLATION). SUFFICIENT HEADER SPACE MUST BE AVAILABLE TO MOUNT THE MAGNETIC LOCK TO INSURE A SAFE AND SECURE INSTALLATION. 1. NOTE TYPE OF FRAME HEADER AND INSTALL FILLER OR ANGLE BRACKET AS REQUIRED TO PROVIDE A FLAT MOUNTING SURFACE ON THE HEADER THE ENTIRE LENGTH OF THE MAGNETIC LOCK. OUTSWINGING INSTALLATION HEADER FILLER HEADER HEADER HEADER ANGLE BRACKET OUT SWINGING MAGNET SOLID OUT SWINGING MAGNET OUT SWINGING MAGNET 2. FOLD TEM ON DOTTED LINE TO FORM A 90 DEGREE ANGLE. TAPE TEM AGAINST HEADER WITH IN A CLOSED POSITION 1 FROM FRAME OPPOSITE HINGE SIDE OF JAMB. FOR A PAIR OF DOUBLE S PLACE TEM AT THE CENTER OF THE OPENING. TRANSFER HOLE LOCATIONS TO AND FRAME HEADER, (SEE TEM INSTRUCTIONS). 3. FOLLOW TEM INSTRUCTIONS FOR HOLE SIZES. USE THE ILLUSTRATIONS BELOW TO DETERMINE THE PROPER HOLE PREPARATION FOR THE ACCCORDING TO THE TYPE IN THE INSTALLATION. THE INCLUDED HARDWARE PACKAGE CONTAINS ALL NECESSARY ITEMS TO COMPLETE THE INSTALLATION. TO REMOVE THE HEADER INSERT HEX KEY INTO HOLES LOCATED AT THE BOTTOM OF LOCK ON THE RIGHT AND LEFT SIDE AND UN-SCREW THE CAP SCREWS HOLLOW FOLLOW WITH 1/2 DIA. HOLE THRU DRILL 1/4 DIA. HOLE THRU SIDE OF DRILL 1/2 DIA. HOLE THRU SEX BOLT SIDE OF DRILL 21/32 DIA. HOLE THRU SIDE OF ONE THICKNESS ONLY ONE THICKNESS ONLY MUST ROCK ON MUST ROCK ON ALARM CONTROLS CORPORATION 19 BRANDYWINE DRIVE P.O. BOX 280 DEER PARK, NY 11729 800 645-5538 WWW.ALARMCONTROLS.COM

INSWINGING INSTALLATION WITH L- Z BRACKET FRAME FASTEN THE L BRACKET ON THE FRAME IN A SUITABLE LOCATION. MOUNT THE MAGNETIC LOCK TO THE L BRACKET. MAKE SURE THAT THE MAGNETIC LOCK DOES NOT OBSTRUCT THE CLOSING OF THE. L BRACKET CONNECT THE CORRECT VOLTAGE TO THE MAGNET. ADJUSTABLE Z BRACKET ASSEMBLE THE Z BRACKET WITH THE SOCKET HEAD CAP SCREWS PROVIDED. DO NOT TIGHTEN THE CAP SCREWS AT THIS TIME. THE Z BRACKET MUST BE ADJUSTABLE. BOLT RUBBER WASHER METAL WASHERS STEP 3 MOUNT THE TO THE ADJUSTABLE SECTION OF THE Z BRACKET WITH THE BOLT. DO NOT REMOVE THE RUBBER WASHER ATTACHED TO THE BOLT. USE ONE RUBBER WASHER BETWEEN TWO METAL WASHERS ON THE BOLT. THE WASHER ASSEMBLY MUST BE BETWEEN THE AND THE ADJUSTABLE SECTION OF THE Z BRACKET. APPLY THE SCREW LOCKING AGENT TO THE BOLT. DO NOT OVER TIGHTEN. MUST ROCK TO ALIGN WITH THE MAGNET. ADJUSTABLE SECTION OF Z BRACKET WITH ATTACHED Z BRACKET ASSEMBLY STEP 4 CLOSE THE AND ALIGN THE TO THE MAGNET AND APPLY POWER TO THE MAGNET. LET THE BOND TO THE MAGNET. BE SURE THE Z BRACKET ASSEMBLY IS FIRMLY AGAINST THE CLOSED. TIGHTEN THE CAP SCREWS HOLDING THE Z BRACKET ASSEMBLY. FASTEN THE Z BRACKET ASSEMBLY TO THE WITH THE SCREWS SUPPLIED. COMPLETED INSWINGING INSTALLATION STEP 5 CHECK THE COMPLETED ALIGNMENT AND INSTALLATION OF THE MAGNET AND BY OPENING AND CLOSING THE BY ENERGIZING AND DE-ENERGIZING THE MAGNETIC LOCK SEVERAL TIMES. THIS WILL INSURE THAT THE CORRECT OPERATION AND ALIGNMENT OF THE MAGNETIC LOCK HAS BEEN PROPERLY INSTALLED.

MAGNETIC LOCK L / Z BRACKETS FOR INSWINGING S AM2370 FOR 300 POUND MAGNETIC LOCK AM3370 FOR ALL 600 POUND MODELS OF SINGLE MAGNETIC LOCKS AM6370 FOR ALL 1200 POUND MODELS OF SINGLE MAGNETIC LOCKS AM3375 FOR ALL 600 POUND MODELS OF DOUBLE MAGNETIC LOCKS AM6375 FOR ALL 1200 POUND MODELS OF DOUBLE MAGNETIC LOCKS MAGNETIC LOCK CARE AND MAINTENANCE MAGNETIC LOCKS HAVE NO INTERNAL MOVING PARTS AND REQUIRE A MINIMUM AMOUNT OF MAINTENANCE. IT IS RECOMMENDED THAT THE FACE OF THE AND MAGNET BE WIPED CLEAN AND A L IGHT COATING OF A SUITABLE SILCONE LUBRICANT BE APPLIED TO EACH SURFACE TO PREVENT RUST ALTHOUGH THE MATING SURFACES HAVE BEEN D. THIS ONLY NEEDS TO BE DONE WHEN DIRT BUILD-UP IS NOTICED. THE BOLT AND THE HEX HEAD SCREWS HOLDING THE MAGNET TO HEADER SHOULD BE CHECKED EVERY THREE MONTHS TO INSURE A SAFE AND SECURE INSTALLATION. MAGNETIC LOCK ELECTRICAL SPECIFICATIONS 300 POUND MODEL SINGLE MAGNETIC LOCK, 250 MA. @ 12 VDC, 130 MA. @ 24 VDC ALL 600 POUND MODELS OF SINGLE MAGNETIC LOCK, 400 MA. @ 12 VDC, 200 MA. @ 24 VDC ALL 1200 POUND MODELS OF SINGLE MAGNETIC LOCK, 400 MA. @ 12 VDC, 200 MA. @ 24 VDC ALL 600 POUND MODELS OF DOUBLE MAGNETIC LOCKS, 400 MA. @ 12 VDC, 200 MA. @ 24 VDC, EACH LOCK ALL 1200 POUND MODELS OF DOUBLE MAGNETIC LOCKS, 400 MA. @ 12 VDC, 200 MA. @ 24 VDC, EACH LOCK ALL MAGNETIC LOCKS ARE SET AT THE FACTORY FOR 24 VDC TYPICAL MAGNETIC LOCK WIRING POSITIVE FILTERED DC POWER SUPPLY N/C REX BUTTON DIGITAL KEYPAD PIR + - MAGNETIC LOCK NEGATIVE

WIRE GAUGE CHART DISTANCE FROM POWER SUPPLY TO MAGNETIC LOCK 12 VDC 24 VDC 50 100 150 200 300 400 500 750 1000 200 MA. D C 300 MA. C U R R E N T 400 MA. 600 MA. 800 MA. 8 GA. 1 AMP. 8 GA. TROUBLE SHOOTING GUIDE PROBLEM CAUSE SOLUTION LOCK BUZZES INSUFFICIENT HOLDING FORCE DOES NOT LOCK AC VOLTAGE CONNECTED TO LOCK AC RIPPLE IN POWER SUPPLY INCORRECT INPUT VOLTAGE LOW INPUT VOLTAGE MISALIGNMENT OF SCREWED TIGHT TO WRONG HARDWARE ASSEMBLY NO POWER TO SUPPLY DC VOLTAGE TO LOCK REPLACE POWER SUPPLY CHECK VOLTAGE JUMPER POSITION FOR CORRECT VOLTAGE SETTING LOCK SET AT FACTORY FOR 24 VDC CHECK POWER SUPPLY VOLTAGE WIRE GAUGE INCORRECT FOR WIRE RUN MUST COVER ALL MAGNETIC POLES OF LOCK MUST ROCK ON TO ALIGN WITH LOCK A METAL WASHER,RUBBER WASHER AND METAL WASHER MUST BE BETWEEN AND CHECK POWER AT LOCK CHECK POWER SUPPLY CHECK ALL CONNECTIONS STATUS SENSOR NOT WORKING (APPLICABLE MODELS) MAGNET IN NOT ALIGNED WITH LOCK ALIGN MAGNET IN WITH STATUS SENSOR DOT ON LOCK

MODEL 1200 SERIES SINGLE DRILL TEM 1/2 DIA. WIRE HOLE HEADER ADJUSTMENT MOUNTING HOLE HEADER ADJUSTMENT MOUNTING HOLE HEADER MOUNTING PLACE EDGE OF TEM 1 FROM JAMB OPPOSITE HINGES FOR L.H. INSTALLATIONS PLACE EDGE OF TEM 1 FROM JAMB OPPOSITE HINGES FOR L.H. INSTALLATIONS DRILL 1/4 ANTI-ROTATION PIN HOLES 3/4 DEEP DO NOT DRILL THRU LOCATING MOUNTING HOLES A. FOLD TEM AT DOTTED LINE. B. PLACE BOTTOM PORTION OF TEM AGAINST THE. C. LOCATE AND MARK THE THREE HOLES ON. D. LOCATE AND MARK THE TWO ADJUST- MENT HEADER HOLES AND WIRE HOLE ON THE HEADER MOUNT- ING. INSTALLING A. DRILL A LEVEL 1/4 DIA. HOLE THRU THE. FOLLOW WITH A 1/2 DIA. DRILL. THIS IS FOR A SOLID ONLY! B. DRILL TWO 1/ 4 HOLES FOR THE ANTI-ROTATION PINS 3/4 DEEP. C. MOUNT THE TO THE WITH THE SEX BOLT. D. PLACE A METAL WASHER A RUBBER WASHER AND A METAL WASHER ON BOLT BETWEEN AND. E. MUST ROCK ON. STEP 3 HEADER MOUNTING A. MOUNT HEADER TO JAMB USING THE TWO ADJUSTMENT HOLES. B. RUN THE CONTROL CABLE THRU THE WIRE HOLE. C. SLIDE MAGLOCK ON HEADER MOUNTING. D. ADJUST THE POSITION OF MAGLOCK TO CONTACT THE. E. REMOVE MAGLOCK AND SECURE HEADER MOUNTING WITH THE SIX REMAINING SCREWS. STEP 4 INSTALLING MAGNET A. SLIDE MAGLOCK ON HEADER. B. FASTEN MAGLOCK TO HEADER WITH THE ALLEN HEAD CAP SCREWS LOCATED AT EACH END OF THE LOCK. C. AFTER CHECKING FOR PROPER OPER- ATION AND ALIGNMENT APPLY THE SCREW LOCKING AGENT TO HEADER MOUNTING SCREWS, BOLT AND ALLEN CAP SCREWS. ALARM CONTROLS CORPORATION, DEER PARK, NY 11729

MAGNETIC LOCK WIRING INSTRUCTIONS MODELS 600S, 600L, 600D, 1200S, 1200L To remove the header plate, it may be necessary to remove the wiring compartment screw. A long wiring compartment screw can be used to increase security by limiting access to the header plate mounting screw from below the lock. WIRING INSTRUCTIONS VOLTAGE IS FACTORY SET FOR 24VDC OPERATION. For 12VDC operation, access the voltage selection switch via the wiring compartment. 600 Series 1200 Series A terminal block is provided for wiring the maglock to the power supply. For models 600L and 1200L a pair of flying leads are provided for the LED. Connect the Red Lead to (V+) and the Black LED to (V-) ALIGNMENT OF THE MAGLOCK AND Align the maglock and armature plate as shown. Armature plate must be mounted to door using the rubber washer sandwiched between the metal washers provided. Do not excessively tighten bolt. Armature must float on door. Screw locking agent is provided on each screw. MAGLOCK WIRING COMPART- MENT UNIVERSAL MOUNTING BOLT HOLE FOR STANDARD OR OFFSET MOUNTING OF ANTI-ROTATION PINS MECHANICAL KICK-OFF DEVICE Alarm Controls Corporation Deer Park, New York 11729 (800) 645-5538 www.alarmcontrols.com ASSA ABLOY, the global leader in door opening solutions MAGInst7-13