HYPRO DUO REACT TWO OUTLET NOZZLE BODY SYSTEM FEATURES & BENEFITS Electro- (Leader) Supports increased speed range while maintaining droplet size control and optimizing spray efficacy Automatically switches nozzles based on speed to provide droplet size stability over a large speed range Allows use of industry leading air induction nozzles to make a reliable spray application Fast on/off section control (.3 seconds) with integrated air stops at each nozzle Easy to install; Works side-by-side with rate controller without having to communication with the controller (Follower) Duo React Console Easily switch nozzles from the cab to select the correct nozzle for the application chemistry Simple console allows for automatic or manual switching between Nozzle A, Nozzle B or Nozzles A + B Apply variable rate liquid fertilizer by selecting the nozzle size combination that offers your desired application.
APPLICATION OPTIONS The Duo React s unique dual port design allows for a variety of application options: 1. Flexibility of Speeds: With proper nozzle selection, you can drive a wider speed range and maintain application rate and spray quality desired by switching between two different nozzle sizes. Nozzle B Nozzle A Speed: 4mph (6 kph) 7 mph (11 kph) 11 mph (18 kph) NOZZLE A NOZZLE B NOZZLE A + B 18 mph (29 kph) Field Examples: Turning corners or traveling up hill Flat, open field (top speeds) 2. Variable Rate Applications: Apply variable rate liquid fertilizer by selecting the nozzle size combination that offers your desired application range. Nozzle A Nozzle B Nozzle A+B 3. Boundary Spraying: Utilize a drift reduction nozzle around the boundary of your field or other obstacles including grass waterways, hedges, drainage tile inlets and ditches. Then switch to a standard nozzle for the rest of the field. Drift Reducing Nozzle Standard Nozzle Sensitive Areas Wetland Grass Waterway BOOM CONFIGURATION EXAMPLE Switching Node (Follower) (Follower) Electro- Nozzle Body (Leader) (Follower) Electro-pneumatic (leader) nozzle body replaces section control valve Sections can be redefined without changing pipe layout 2 DUO REACT
DUO REACT NOZZLE BODIES FEATURES & BENEFITS A single and 4-way turret nozzle body incorporated into one compact unit - Eliminates the need for twin lines or back to back configurations - Simple operation, twin valves allow either or both nozzles to spray actuated valves are integrated into the nozzle body for a compact design and provides air-to-open fail safe actuation Integrated push-to-connect air porting is easy, secure and rugged while allowing for simple daisy chain connections Clamp Size Electro- 1/2" 4214-2502V 4214-1502V 3/4" 4214-2503V 4214-1503V 1" 4214-2504V 4214-1504V 20mm 4214-2507V 4214-1507V 25mm 4214-2508V 4214-1508V GENERAL SPECIFICATION Operating Temperature range 32 F 122 F (0-50 C) Industry standard male bayonet connection Inlet to fluid pipe 3/8 Max pressure drop 5psi for 1.7 gpm (0.35 bar for 6.4 l/min flow) Waterproof to BSEN60529 (IP65) Tolerant to UV, dust, vibration and impact likely to be encountered in an agricultural spraying environment Viton elastomers for chemical resistance Spares and Tools O-ring and piston sub-assembly kit 3430-0840V Cap removal service wrench 3021-0006 DUO REACT ELECTRO-PNEUMATIC (LEADER) DUO REACT PNEUMATIC (FOLLOWER) Flow to each nozzle individually controlled by 12 VDC signal Surge protected, range tolerated 9-16 VDC Max current draw 0.25 amps for each solenoid actuation of valves at 40-100 psi (3-7 bar) Can be used as a section control valve, actuating multiple pneumatic followers Response time when controlling 7 pneumatic followers 0.1 seconds (open) 0.3 seconds (close) using 4mm diameter 600mm hose and 40-60psi (3-4 bar) Wet gross weight including caps and nozzles 13oz (364g) Tyco AMP Superseal connector Push fit air connectors: 6mm inlet, 4mm outlet Air actuated 40-115psi (3-8 bar), normally closed Nozzle valve selection response time 0.1 seconds Wet gross weight including caps and nozzles 8oz (225g) 4mm push fit air inlet and outlet connectors DIMENSIONS Leader Follower In mm In mm Height 3.27 83 3.27 83 Width 5.47 139 3.66 93 Depth 4.37 111 4.37 111 DUO REACT 3
DUO REACT CONSOLE Program console to manage droplet size by switching between nozzle sizes Choose from automatic or manual nozzle switching Stores up to four configurations for repeated use Monitor nozzle output status from the cab Allows user to set deadband to control hysteresis US or Metric unit setting CONSOLE Description 2850-0028 Duo React Console (includes power cable and mounting hardware) SWITCHING NODES Description 2510-0064 Duo React switching note Node AmpSeal-16, 4 position 2510-0065 Duo React switching note Node Weather Pack Shroud 3 pin AmpSeal-16 CABLES KITS Weather Pack Description 2520-0223 Y-Cable 2520-0224 15' 4-pin Amp Superseal Extension Cable (node to leader) 2520-0225 5' 2-pin M/P150 Extension Cable (node to node) 2520-0226 10' 2-pin M/P150 Extension Cable (node to node) 2520-0227 15' 2-pin M/P150 Extension Cable (node to node) 2520-0228 20' 2-pin M/P150 Extension Cable (node to node) 2520-0229 25' 2-pin M/P150 Extension Cable (node to node) 2520-0231 5' 3-pin W/P150 Extension Cable (section valve to node) 2520-0232 10' 3-pin W/P150 Extension Cable (section valve to node) 2520-0233 15' 3-pin W/P150 Extension Cable (section valve to node) 2520-0234 20' 3-pin W/P150 Extension Cable (section valve to node) 2520-0235 25' 3-pin W/P150 Extension Cable (section valve to node) Description 3430-0940 Air Supply Parts Kit (4&6mm tubing, termination plugs, fittings) 4 DUO REACT
SYSTEM SET-UP GPS speed sensor To 12V battery power EXAMPLE CONFIGURATION Centrally Manifolded section valves Take connectors off section valves (leave valves in the open position). Connect to switching nodes with 2520-0231 - 2520-0235 cables of appropriate length 2520-0231 - 2520-0235 extension, section valve to switching nodes 2520-0223 Y Cable 2520-0229 25ft extensions 2510-0065 3 wire swiching node mounts in close proximity to Leader Nozzle Body. 1 per section LEADER LEADER 2520-0225 - 2520-0229 extension connecting all switching nodes to Y cable determine lengths LEADER ELECTRICAL CONNECTIONS A typical Duo React system uses a switching node at each section valve location to actuate the leader nozzle body. The on/off control signal from the existing section control valve drives the leader nozzle body. Nozzle port control from Duo React Console located in the cab links to each node by a 2 wire extension cable. AIR LINE CONNECTIONS All fittings and tubing needed comes in the Air Supply Parts Kit to complete the air supply connections. A 6mm diameter tubing is run from the air supply on the sprayer back to the boom, through a tee fitting and then is daisy chained through push-to-connect (PTC) porting at each Duo React leader nozzle body. A 4mm diameter tubing is supplied to complete daisy chain connection from leader to follower nozzle bodies using push-to-connect porting (shown above). Air system requirement is very low, at just 0.16 liter (0.006 SCF) per 8 nozzle body configuration. SOLUTION LINE CONNECTIONS On an existing sprayer the solution lines can stay connected with section control valves inline (open state) with on/off control provided at the Duo React leader integrated pneumatic air stop. Alternatively, with Duo React leader nozzle body controlling flow, section control valves can be eliminated with a single feed line running down the entire length of the boom to feed the individual boom pipe sections. With Duo React the number of nozzle bodies per section can be rebalanced by simply connecting airline independent of what pipe they are mounted on. SAMPLE NOZZLE SELECTION AND CONTROL POINT SETUP Find your closest application rate in the column headers. Scan down the column until you find the min and max speed range that suits your needs. Select the nozzles to the left and enter the setpoints as pre-selected in the chart below. Contact and Systemic charts will follow in this brochure. Nozzle B Nozzle A Setpoints (mph) FC-ULD120-025 FC-ULD120-03 FC-ULD120-015 FC-ULD120-02 Application Rate (GPA) 5 7.5 10 12.5 Min Speed 6.3 4.2 3.2 2.5 Setpoint 2 (B to A+B) 18.2 12.1 9.1 7.3 Min Speed 8.4 5.6 4.2 3.4 Max Speed 36.4 24.2 18.2 14.5 Setpoint 1 (A to B) 14.5 9.7 7.3 5.8 Setpoint 2 (B to A+B) 21.8 14.5 10.9 8.7 DUO REACT 5
DUO REACT NOZZLE SELECTION - US UNITS SYSTEMIC NOZZLE PAIRS Droplets: C or Greater Pressure Range: 20 to 60 psi 5 7.5 10 12.5 15 17.5 20 22.5 25 5 7.5 10 12.5 15 17.5 20 22.5 25 Min Speed 8.4 5.6 4.2 3.4 2.8 2.4 2.1 1.9 1.7 6.3 4.2 3.2 2.5 2.1 1.8 1.6 1.4 1.3 Max Speed 38.8 25.9 19.4 15.5 12.9 11.1 9.7 8.6 7.8 29.1 19.4 14.5 11.6 9.7 8.3 7.3 6.5 5.8 Setpoint 1 (A to B) 14.5 9.7 7.3 5.8 4.8 4.2 3.6 3.2 2.9 10.9 7.3 5.5 4.4 3.6 3.1 2.7 2.4 2.2 FC-ULD120-025 FC-ULD120-015 Setpoint 2 (B to A+B) 24.2 16.2 12.1 9.7 8.1 6.9 6.1 5.4 4.8 18.2 12.1 9.1 7.3 6.1 5.2 4.5 4.0 3.6 Min Speed 11.2 7.5 5.6 4.5 3.7 3.2 2.8 2.5 2.2 8.4 5.6 4.2 3.4 2.8 2.4 2.1 1.9 1.7 Max Speed 48.5 32.3 24.2 19.4 16.2 13.9 12.1 10.8 9.7 36.4 24.2 18.2 14.5 12.1 10.4 9.1 8.1 7.3 Setpoint 1 (A to B) 19.4 12.9 9.7 7.8 6.5 5.5 4.8 4.3 3.9 14.5 9.7 7.3 5.8 4.8 4.2 3.6 3.2 2.9 FC-ULD120-03 FC-ULD120-02 Setpoint 2 (B to A+B) 29.1 19.4 14.5 11.6 9.7 8.3 7.3 6.5 5.8 21.8 14.5 10.9 8.7 7.3 6.2 5.5 4.8 4.4 Min Speed 16.8 11.2 8.4 6.7 5.6 4.8 4.2 3.7 3.4 12.6 8.4 6.3 5.0 4.2 3.6 3.2 2.8 2.5 Max Speed 67.9 45.3 33.9 27.2 22.6 19.4 17.0 15.1 13.6 50.9 33.9 25.5 20.4 17.0 14.5 12.7 11.3 10.2 Setpoint 1 (A to B) 29.1 19.4 14.5 11.6 9.7 8.3 7.3 6.5 5.8 21.8 14.5 10.9 8.7 7.3 6.2 5.5 4.8 4.4 FC-ULD120-04 FC-ULD120-03 Setpoint 2 (B to A+B) 38.8 25.9 19.4 15.5 12.9 11.1 9.7 8.6 7.8 29.1 19.4 14.5 11.6 9.7 8.3 7.3 6.5 5.8 Min Speed 22.4 14.9 11.2 9.0 7.5 6.4 5.6 5.0 4.5 16.8 11.2 8.4 6.7 5.6 4.8 4.2 3.7 3.4 Max Speed 87.3 58.2 43.6 34.9 29.1 24.9 21.8 19.4 17.5 65.5 43.6 32.7 26.2 21.8 18.7 16.4 14.5 13.1 Setpoint 1 (A to B) 38.8 25.9 19.4 15.5 12.9 11.1 9.7 8.6 7.8 29.1 19.4 14.5 11.6 9.7 8.3 7.3 6.5 5.8 FC-ULD120-05 FC-ULD120-04 Setpoint 2 (B to A+B) 48.5 32.3 24.2 19.4 16.2 13.9 12.1 10.8 9.7 36.4 24.2 18.2 14.5 12.1 10.4 9.1 8.1 7.3 CONTACT NOZZLE PAIRS Droplets: M to C Pressure Range: 40 to 90 psi 5 7.5 10 12.5 15 17.5 20 22.5 25 5 7.5 10 12.5 15 17.5 20 22.5 25 Min Speed 11.9 7.9 5.9 4.8 4.0 3.4 3.0 2.6 2.4 8.9 5.9 4.5 3.6 3.0 2.5 2.2 2.0 1.8 Max Speed 47.5 31.7 23.8 19.0 15.8 13.6 11.9 10.6 9.5 35.6 23.8 17.8 14.3 11.9 10.2 8.9 7.9 7.1 Setpoint 1 (A to B) 17.8 11.9 8.9 7.1 5.9 5.1 4.5 4.0 3.6 13.4 8.9 6.7 5.3 4.5 3.8 3.3 3.0 2.7 FC-GA110-025 FC-GA110-015 Setpoint 2 (B to A+B) 29.7 19.8 14.9 11.9 9.9 8.5 7.4 6.6 5.9 22.3 14.9 11.1 8.9 7.4 6.4 5.6 5.0 4.5 Min Speed 15.8 10.6 7.9 6.3 5.3 4.5 4.0 3.5 3.2 11.9 7.9 5.9 4.8 4.0 3.4 3.0 2.6 2.4 Max Speed 59.4 39.6 29.7 23.8 19.8 17.0 14.9 13.2 11.9 44.6 29.7 22.3 17.8 14.9 12.7 11.1 9.9 8.9 Setpoint 1 (A to B) 23.8 15.8 11.9 9.5 7.9 6.8 5.9 5.3 4.8 14.5 9.7 7.3 5.8 4.8 4.2 3.6 3.2 2.9 FC-GA110-03 FC-GA110-02 Setpoint 2 (B to A+B) 35.6 23.8 17.8 14.3 11.9 10.2 8.9 7.9 7.1 21.8 14.5 10.9 8.7 7.3 6.2 5.5 4.8 4.4 Min Speed 23.8 15.8 11.9 9.5 7.9 6.8 5.9 5.3 4.8 17.8 11.9 8.9 7.1 5.9 5.1 4.5 4.0 3.6 Max Speed 83.2 55.4 41.6 33.3 27.7 23.8 20.8 18.5 16.6 62.4 41.6 31.2 24.9 20.8 17.8 15.6 13.9 12.5 Setpoint 1 (A to B) 35.6 23.8 17.8 14.3 11.9 10.2 8.9 7.9 7.1 26.7 17.8 13.4 10.7 8.9 7.6 6.7 5.9 5.3 FC-GA110-04 FC-GA110-03 Setpoint 2 (B to A+B) 47.5 31.7 23.8 19.0 15.8 13.6 11.9 10.6 9.5 35.6 23.8 17.8 14.3 11.9 10.2 8.9 7.9 7.1 Min Speed 31.7 21.1 15.8 12.7 10.6 9.1 7.9 7.0 6.3 23.8 15.8 11.9 9.5 7.9 6.8 5.9 5.3 4.8 Max Speed 106.9 71.3 53.5 42.8 35.6 30.5 26.7 23.8 21.4 80.2 53.5 40.1 32.1 26.7 22.9 20.0 17.8 16.0 Setpoint 1 (A to B) 47.5 31.7 23.8 19.0 15.8 13.6 11.9 10.6 9.5 35.6 23.8 17.8 14.3 11.9 10.2 8.9 7.9 7.1 FC-GA110-05 FC-GA110-04 Setpoint 2 (B to A+B) 59.4 39.6 29.7 23.8 19.8 17.0 14.9 13.2 11.9 44.6 29.7 22.3 17.8 14.9 12.7 11.1 9.9 8.9 6 DUO REACT
DUO REACT NOZZLE SELECTION - METRIC UNITS SYSTEMIC NOZZLE PAIRS Droplets: C or Greater Pressure Range: 1.5 to 4 bar Nozzle B Nozzle A Setpoints (KPH) Application Rate (L/HA) - 38cm Spacing Application Rate (L/HA) - 50cm Spacing 40 60 80 100 120 140 160 180 200 40 60 80 100 120 140 160 180 200 Min Speed 21.2 14.1 10.6 8.5 7.1 6.1 5.3 4.7 4.2 12.7 8.5 6.4 5.1 4.2 3.6 3.2 2.8 2.5 Max Speed 92.4 61.6 46.2 37.0 30.8 26.4 23.1 20.5 18.5 55.4 37.0 27.7 22.2 18.5 15.8 13.9 12.3 11.1 Setpoint 1 (A to B) 34.6 23.1 17.3 13.9 11.5 9.9 8.7 7.7 6.9 20.8 13.9 10.4 8.3 6.9 5.9 5.2 4.6 4.2 FC-ULD120-025 FC-ULD120-015 Setpoint 2 (B to A+B) 57.7 38.5 28.9 23.1 19.2 16.5 14.4 12.8 11.5 34.6 23.1 17.3 13.9 11.5 9.9 8.7 7.7 6.9 Min Speed 28.3 18.9 14.1 11.3 9.4 8.1 7.1 6.3 5.7 17.0 11.3 8.5 6.8 5.7 4.8 4.2 3.8 3.4 Max Speed 115.5 77.0 57.7 46.2 38.5 33.0 28.9 25.7 23.1 69.3 46.2 34.6 27.7 23.1 19.8 17.3 15.4 13.9 Setpoint 1 (A to B) 46.2 30.8 23.1 18.5 15.4 13.2 11.5 10.3 9.2 27.7 18.5 13.9 11.1 9.2 7.9 6.9 6.2 5.5 FC-ULD120-03 FC-ULD120-02 Setpoint 2 (B to A+B) 69.3 46.2 34.6 27.7 23.1 19.8 17.3 15.4 13.9 41.6 27.7 20.8 16.6 13.9 11.9 10.4 9.2 8.3 Min Speed 42.4 28.3 21.2 17.0 14.1 12.1 10.6 9.4 8.5 25.5 17.0 12.7 10.2 8.5 7.3 6.4 5.7 5.1 Max Speed 153.0 102.0 76.5 61.2 51.0 43.7 38.2 34.0 30.6 91.8 61.2 45.9 36.7 30.6 26.2 22.9 20.4 18.4 Setpoint 1 (A to B) 69.3 46.2 34.6 27.7 23.1 19.8 17.3 15.4 13.9 41.6 27.7 20.8 16.6 13.9 11.9 10.4 9.2 8.3 FC-ULD120-04 FC-ULD120-03 Setpoint 2 (B to A+B) 92.4 61.6 46.2 37.0 30.8 26.4 23.1 20.5 18.5 55.4 37.0 27.7 22.2 18.5 15.8 13.9 12.3 11.1 Min Speed 56.6 37.7 28.3 22.6 18.9 16.2 14.1 12.6 11.3 33.9 22.6 17.0 13.6 11.3 9.7 8.5 7.5 6.8 Max Speed 196.9 131.3 98.4 78.8 65.6 56.3 49.2 43.8 39.4 118.1 78.8 59.1 47.3 39.4 33.8 29.5 26.3 23.6 Setpoint 1 (A to B) 92.4 61.6 46.2 37.0 30.8 26.4 23.1 20.5 18.5 55.4 37.0 27.7 22.2 18.5 15.8 13.9 12.3 11.1 FC-ULD120-05 FC-ULD120-04 Setpoint 2 (B to A+B) 115.5 77.0 57.7 46.2 38.5 33.0 28.9 25.7 23.1 69.3 46.2 34.6 27.7 23.1 19.8 17.3 15.4 13.9 CONTACT NOZZLE PAIRS Droplets: M to C Pressure Range: 3 to 6 bar Nozzle B Nozzle A Setpoints (KPH) Application Rate (L/HA) - 38cm Spacing Application Rate (L/HA) - 50cm Spacing 40 60 80 100 120 140 160 180 200 40 60 80 100 120 140 160 180 200 Min Speed 30.0 20.0 15.0 12.0 10.0 8.6 7.5 6.7 6.0 18.0 12.0 9.0 7.2 6.0 5.1 4.5 4.0 3.6 Max Speed 84.9 56.6 42.4 33.9 28.3 24.2 21.2 18.9 17.0 67.9 45.3 33.9 27.2 22.6 19.4 17.0 15.1 13.6 Setpoint 1 (A to B) 42.4 28.3 21.2 17.0 14.1 12.1 10.6 9.4 8.5 25.5 17.0 12.7 10.2 8.5 7.3 6.4 5.7 5.1 FC-GA110-025 FC-GA110-015 Setpoint 2 (B to A+B) 70.7 47.1 35.4 28.3 23.6 20.2 17.7 15.7 14.1 42.4 28.3 21.2 17.0 14.1 12.1 10.6 9.4 8.5 Min Speed 40.0 26.7 20.0 16.0 13.3 11.4 10.0 8.9 8.0 24.0 16.0 12.0 9.6 8.0 6.9 6.0 5.3 4.8 Max Speed 141.4 94.3 70.7 56.6 47.1 40.4 35.4 31.4 28.3 84.9 56.6 42.4 33.9 28.3 24.2 21.2 18.9 17.0 Setpoint 1 (A to B) 56.6 37.7 28.3 22.6 18.9 16.2 14.1 12.6 11.3 33.9 22.6 17.0 13.6 11.3 9.7 8.5 7.5 6.8 FC-GA110-03 FC-GA110-02 Setpoint 2 (B to A+B) 84.9 56.6 42.4 33.9 28.3 24.2 21.2 18.9 17.0 50.9 33.9 25.5 20.4 17.0 14.5 12.7 11.3 10.2 Min Speed 60.0 40.0 30.0 24.0 20.0 17.1 15.0 13.3 12.0 36.0 24.0 18.0 14.4 12.0 10.3 9.0 8.0 7.2 Max Speed 187.4 124.9 93.7 75.0 62.5 53.5 46.8 41.6 37.5 112.4 75.0 56.2 45.0 37.5 32.1 28.1 25.0 22.5 Setpoint 1 (A to B) 84.9 56.6 42.4 33.9 28.3 24.2 21.2 18.9 17.0 50.9 33.9 25.5 20.4 17.0 14.5 12.7 11.3 10.2 FC-GA110-04 FC-GA110-03 Setpoint 2 (B to A+B) 113.1 75.4 56.6 45.3 37.7 32.3 28.3 25.1 22.6 67.9 45.3 33.9 27.2 22.6 19.4 17.0 15.1 13.6 Min Speed 80.0 53.3 40.0 32.0 26.7 22.9 20.0 17.8 16.0 48.0 32.0 24.0 19.2 16.0 13.7 12.0 10.7 9.6 Max Speed 241.1 160.7 120.6 96.4 80.4 68.9 60.3 53.6 48.2 144.7 96.4 72.3 57.9 48.2 41.3 36.2 32.1 28.9 Setpoint 1 (A to B) 113.1 75.4 56.6 45.3 37.7 32.3 28.3 25.1 22.6 67.9 45.3 33.9 27.2 22.6 19.4 17.0 15.1 13.6 FC-GA110-05 FC-GA110-04 Setpoint 2 (B to A+B) 141.4 94.3 70.7 56.6 47.1 40.4 35.4 31.4 28.3 67.9 45.3 33.9 27.2 22.6 19.4 17.0 15.1 13.6 DUO REACT 7
DUO REACT NOZZLE SELECTION - BY SPECIFIC CHEMISTRY ENLIST DUO NOZZLE PAIRS Droplets: C or Greater Speeds apply to pressures stated on label (04 = 20-70psi, 06=20-50psi) 5 7.5 10 12.5 15 17.5 20 22.5 25 5 7.5 10 12.5 15 17.5 20 22.5 25 Min Speed 22.4 14.9 11.2 9.0 7.5 6.4 5.6 5.0 4.5 16.8 11.2 8.4 6.7 5.6 4.8 4.2 3.7 3.4 Max Speed 88.5 59.0 44.3 35.4 29.5 25.3 22.1 19.7 17.7 66.4 44.3 33.2 26.6 22.1 19.0 16.6 14.8 13.3 Setpoint 1 (A to B) 41.9 27.9 21.0 16.8 14.0 12.0 10.5 9.3 8.4 31.4 21.0 15.7 12.6 10.5 9.0 7.9 7.0 6.3 FC-ULD120-04 FC-ULD120-06 Setpoint 2 (B to A+B) 56.0 37.3 28.0 22.4 18.7 16.0 14.0 12.4 11.2 42.0 28.0 21.0 16.8 14.0 12.0 10.5 9.3 8.4 ENLIST ONE NOZZLE PAIRS Droplets: C or Greater Speeds apply to pressures stated on label (04 =20-80psi, 05=20-70psi, 06=20-65psi) 5 7.5 10 12.5 15 17.5 20 22.5 25 5 7.5 10 12.5 15 17.5 20 22.5 25 Min Speed 22.4 14.9 11.2 9.0 7.5 6.4 5.6 5.0 4.5 16.8 11.2 8.4 6.7 5.6 4.8 4.2 3.7 3.4 Max Speed 94.3 62.9 47.1 37.7 31.4 26.9 23.6 21.0 18.9 70.7 47.1 35.4 28.3 23.6 20.2 17.7 15.7 14.1 Setpoint 1 (A to B) 44.8 29.9 22.4 17.9 14.9 12.8 11.2 10.0 9.0 33.6 22.4 16.8 13.4 11.2 9.6 8.4 7.5 6.7 FC-ULD120-05 FC-ULD120-04 Setpoint 2 (B to A+B) 52.4 34.9 26.2 21.0 17.5 15.0 13.1 11.6 10.5 39.3 26.2 19.6 15.7 13.1 11.2 9.8 8.7 7.9 Min Speed 28.0 18.7 14.0 11.2 9.3 8.0 7.0 6.2 5.6 21.0 14.0 10.5 8.4 7.0 6.0 5.3 4.7 4.2 Max Speed 106.7 71.1 53.3 42.7 35.6 30.5 26.7 23.7 21.3 80.0 53.3 40.0 32.0 26.7 22.9 20.0 17.8 16.0 Setpoint 1 (A to B) 52.4 34.9 26.2 21.0 17.5 15.0 13.1 11.6 10.5 39.3 26.2 19.6 15.7 13.1 11.2 9.8 8.7 7.9 FC-ULD120-06 FC-ULD120-05 Setpoint 2 (B to A+B) 58.2 38.8 29.1 23.3 19.4 16.6 14.5 12.9 11.6 43.6 29.1 21.8 17.5 14.5 12.5 10.9 9.7 8.7 ENGENIA NOZZLE PAIRS Droplets: C or Greater Speeds apply to pressures stated on label (04 = 20-70psi, 06=20-50psi) 10 12.5 15 17.5 20 22.5 25 10 12.5 15 17.5 20 22.5 25 Min Speed 11.2 9.0 7.5 6.4 5.6 5.0 4.5 8.4 6.7 5.6 4.8 4.2 3.7 3.4 Max Speed 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 14.5 13.1 Setpoint 1 (A to B) 19.4 15.5 12.9 11.1 9.7 8.6 7.8 14.5 11.6 9.7 8.3 7.3 6.5 5.8 FC-ULD120-05 FC-ULD120-04 Setpoint 2 (B to A+B) 24.2 19.4 16.2 13.9 12.1 10.8 9.7 18.2 14.5 12.1 10.4 9.1 8.1 7.3 Min Speed 14.0 11.2 9.3 8.0 7.0 6.2 5.6 10.5 8.4 7.0 6.0 5.3 4.7 4.2 Max Speed 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 15.0 14.6 Setpoint 1 (A to B) 24.2 19.4 16.2 13.9 12.1 10.8 9.7 18.2 14.5 12.1 10.4 9.1 8.1 7.3 FC-ULD120-06 FC-ULD120-05 Setpoint 2 (B to A+B) 26.6 21.3 17.7 15.2 13.3 11.8 10.6 19.9 15.9 13.3 11.4 10.0 8.9 8.0 375 Fifth Avenue NW New Brighton, MN 55112, United States 651-766-6300 F: 651-766-6600 hypro.sales@pentair.com All Pentair trademarks and logos are owned by Pentair, Inc. All other brand or product names are trademarks or registered marks of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer. Form 488 9/18 2018 Pentair, Inc. All Rights Reserved.