Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

Similar documents
Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

Model J. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations available

Metal Particle Detector

Model H. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Thermostatic Control Valves

Intake Air Shut-off Valve

Pilot Operated 2-Way Gas Valves

Model E. Thermostatic Control Valves. Typical applications

Pneumatic Indicating Relay

2-Way Temperature Sensing Valves

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

3-Way Temperature Control Valve

Thermostatic Control Valve

Metal Particle Detector

Thermostatic Control Valve

Thermostatic Control Valve

Optimise your temperature control

Pressure and Temperature Switches

3-Way Temperature Control Valve

Is the heart of your engine protected?

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDB3 Compact Butterfly Valve. by AMOT. Overview. Typical Applications

Diesel Engine Air Intake Shutoff Valves

3-Way Temperature Control Valve

Air Intake Shut-off Valve

HVX-Series Diesel Engine Shut Down Valves (Oil Pressure Latched Types with Manual Start Override/Emergency Stop)

SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop)

Solenoid Actuated Diesel Engine Air Shut Down Valves

SVX-Series Solenoid Actuated Diesel Air Shut Down Valves

Diesel Engine Shutdown Valves

MVX-Series Diesel Engine Air Shut Down Valves

System Selection Guide

Model B. Thermostatic Valves FEATURES APPLICATIONS FLOW RATES OF USGPM TAMPER-PROOF TEMPERATURE SETTINGS OF 55 F F

Flameproof Alternators

XTS-W+ Bearing Condition Monitor

Diesel Engine Shutdown Valve

by AMOT World class diesel engine safety solutions Automatic Engine Overspeed Shut Down Valves - D Series

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

Automatic Fuel Shut Down Valves

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

How efficient is your temperature control?

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Stop Types)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run Types for Non-Hazardous Areas)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

Diesel Engine Safety Solutions. Automatic Engine Overspeed Shut Down Valves - D Series

Flameproof Alternator

THERMOSTAT PROBE PACKAGES: FAST RESPONSE, TINY STAT TM

Thermal Dispersion Flow Switch.

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 123

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 120

Daniel Measurement & Control - Product Training Calendar

Self-Exciting Flameproof Alternator

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

FLUID POWER PRODUCTS WINTERS INSTRUMENTS. MANUFACTURER OF INDUSTRIAL INSTRUMENTATION

Thermal Dispersion & Paddle Type Flow Switch

Data Sheet P265 Stainless Steel Pressure Transducer

D-Series Automatic Engine Overspeed Shut Down Valves (Mini Range)

Thermal Dispersion & Paddle Type Flow Switch.

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

Process Industry. Specification Guide. For. Pressure & Temperature Instruments & Related Accessories

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

World class manufacturer of safety solutions SYSTEM SELECTION GUIDE. Safety solutions for vehicles and machines working in petrochemical plants

D200 Spindle Type Automatic Engine Overspeed Air Intake Shut Down Valve (including Manual, Oil and Air Pressure Shut Down Control options)

XCEL80 Steering Control Units

Flameproof Alternator

P500 Pressure Sensor. Description. Features. Applications MAIN FEATURES

Products for the Oil & Gas Industry

Data Sheet P255 Stainless Steel Pressure Transducer

Oil Mist Detection multi-sensor-system for 2-stroke engines

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 124

Data Sheet P4055 Pressure Transducer

Form No. P Meter, PD Model SD, ASD, SF, or ASF-4, 4R, 4V, or 4RV-NF Parts List

Revision MOVITRAC LTE-B * _1114*

Eaton. Revised April, Directional Control Valves. Model 30540, 15 GPM Directional Control Valves. We Manufacture. Solutions

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

S Series Technical Data...7 How to Order...8 Dimensions...8 Manifold Dimensions and Part Numbers...9

BARTON 7000 Series Liquid Turbine Meters

Flameproof Alternator

PISTON STYLE GAUGE. Mid-West Instrument

P255 Stainless Steel Pressure Transducer

Data Sheet P1A Pressure Sensor

Diesel Engine Shutdown System

by AMOT World class diesel engine safety solutions Product Selection Guide

CBA-Series Pneumatic Dimension Data Metric

Bornemann Pumps and More Introducing a Global System Partner

VAM SLIJ II TM The Semi-Flush connection from a name you trust

EXPLOSION PROOF. Diesel Engines For Hazardous Areas

Replacing the Meter Body / Process Head Parts

Behringer Ball Valve Ordering Code

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

7BT2 SERIES 30 F to 400 F, High Capacity, ½

Portable Power Accessories

UNIVERSAL. Flow Monitors Inc. INSITE Series PX - IS - TX Flow Rate Indicators and Switches

OBSOLETE. Data Sheet P1E Oxygen Service Pressure Sensor. Main Features. Typical Applications. Attributes. Description

BALL VALVES BALL VALVES DN PN 63, 40

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

O.E.M GAUGES. For Installation and Operation Manuals Please Visit: Mid-West Instrument

Product Data Sheet. Industrial Oval Gear. Inline and Flanged Meters, 1/2", 3/4", 1", 1" HF, 1-1/2", 2", 3" DESCRIPTION OPERATING PRINCIPLE

CONTROLLERS & SPECIAL VALVES

metal clad wiring accessories A rugged scratch resistant metal, suitable for everyday use in commercial and industrial environments

Transcription:

Thermostatic Valve Filterstat - Model FJA Typical applications Mixing Diverting Key features and benefits Direct filter connection Integral differential pressure switch Integral oil filter manifold Mount in any position Model FJA Filterstat Valve www.amot.com

Applications Oil cooling system Compressor The diagram on the left shows a typical installation of the Filterstat. Filter Cooler DP AMOT FILTERSTAT DP SWITCH OPTIONAL Specification Flow rate 2 to 5.5 m 3 /hr Recommended pressure 0.14 to 0.5 bar drop Body materials Aluminium (2 to 7 PSI) Ports Below nominal temperature Ports A and B connected Seal materials Above nominal temperature Viton Valve sizes 20mm ( 3 /4 ) (nominal bore) Ports A and C connected Port connections Screwed 20mm ( 3 /4 ) BSP, NPT, M26 x 1.5, JIS, SAE Control temperatures 49 to 113 C (see Element Characteristics Table) Maximum working 25 bar (362 PSI) pressure Mounting position Any orientation Switch specification Delta P (rising) 1.7 bar (25 PSI +/-2 PSI) Max P Switch type 25 bar Max current 1.0A Max voltage Max power Electrical cord SPDT normally open as standard 150VDC 20W Grey PVC casing over 3.24 AWG wires White (com) Red (N.O.) Black (N.C.) Length 1525mm (60 ) Please note that the DP switch can be removed and replaced without need for subsequent calibration or set-up. page 2

Valve characteristics Pressure drop Element characteristics All temperatures in C ( F) Pressure drop bar (PSI) 1.38 (20) 1.24 (18) 1.10 (16) 0.96 (14) 0.83 (12) 0.69 (10) 0.55 (8) 0.41 (6) 0.28 (4) Control temperature Rated range Max temperature continuous Code 49 (120) 43-55 (110-131) 86 (187) 120 54 (130) 49-60 (120-140) 95 (203) 130 60 (140) 54-65 (130-150) 95 (203) 140 65 (150) 60-71 (140-160) 100 (212) 150 71 (160) 65-76 (150-170) 100 (212) 160 76 (170) 72-82 (163-180) 100 (212) 170 80 (175) 76-85 (170-185) 105 (221) 175 82 (180) 79-88 (175-190) 110 (230) 180 87 (190) 85-93 (185-200) 110 (230) 190 93 (200) 90-100 (194-212) 110 (230) 200 96 (205) 93-103 (200-218) 110 (230) 250 101 (215) 97-107 (205-225) 115 (239) 215 107 (225) 101-114 (214-237) 120 (248) 225 113 (235) 107-123 (225-253) 124 (257) 235 0.14 (2) Size s s s s 3 /4 2 4 6 8 Flowrate m 3 /hr water Valve dimensions 47.4 63.1 31.9 12.4 7.1 9.5 36.4 12.7 Weight 2.3 kg (5.1 lbs) 31 (41.3) 121.6 54 25mm (1" 12 UNF) 20mm ( 3 /4") BSP (PL) 4 PORTS 65.5 Dimensions in mm 27.3 17.8 127 31.8 13.2 page 3

How to order Use the tables below to select the unique specification of your Filterstat Valve Example Code 3 /4FJA2 T A 120 01 N 0 -AA Code Description Model & Revision Level Connections Filter Adapter Control Temperature Element Specification Leakhole Sizes mm (inches) Switch Model & Revision Level 3 /4FJA2 3/4 aluminum valve Connections T Threaded NPT to USAS B2.1 U V W Special Customer Requirements Threaded BSP(PI) to BS21 Threaded BSP (Tr) Japanese (JIS) Threaded to SAE J514h (straight thread o-ring seal) K Threaded to M26 x 1.5 A Filter Adapter 25.4 mm (1 ) - 12 UNF Control Temperature See element characteristics table Element Specification 01 Standard element 02 Plated with Viton seals 03 Standard element with Viton o-rings 04 Plated element with Neoprene o-rings 05 Standard element with Neoprene o-rings N A Leakhole Sizes mm (inches) None 1.6 (1/16 ) standard B 2.4 (3/32 ) C 3.2 (1/8 ) D 0.8 (1/32 ) Switch 0 No DP switch 1 With DP switch -AA Special Customer Requirements Standard Please contact us with any special requirements page 4

Europe, Middle East and Africa AMOT Western Way Bury St Edmunds Suffolk, IP33 3SZ England Tel +44 (0) 1284 762222 Fax +44 (0) 1284 760256 Email info@amot.com Americas AMOT USA 8824 Fallbrook Dr Houston, TX 77064 USA Tel +1 (281) 940 1800 Fax +1 (713) 559 9419 Email general: sales@amotusa.com orders: orders@amotusa.com customer service: cs@amotusa.com AMOT Controls GmbH Rondenbarg 25 22525 Hamburg Germany Tel +49 (0) 40 8537 1298 Fax +49 (0) 40 8537 1331 Email germany@amot.com AMOT Russia #34 Shabolovka Street Building 2 Moscow 115419 Russia Tel +7 495 617 12 93 Fax +7 495 913 97 65 Email russia@amot.com Asia and Australasia AMOT Shanghai Rm A8-671 Jiahua Business Center 808 Hongqiao Road Shanghai 200030 China Tel +86 (0) 21 6447 9708 Fax +86 (0) 21 6447 9718 Email shanghai@amot.com AMOT Singapore 10 Eunos Road 8 #12-06 Singapore Post Centre Singapore 408600 Tel +65 6408 6265 Fax +65 6293 3307 Email singapore@amot.com www.amot.com