CACC condensers CDCC dry coolers Capacity range kw

Similar documents
09GDV and 09LDV. Air Cooled Dry coolers and Condensers

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

DXP 100 Air Cooled Condenser

DXP 100. Dry Cooler CERTIFY-ALL DX COOLERS

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

09DK054, 064, 074, 084, 094 AIR-COOLED CONDENSERS

ENR Incorporating

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

30GX AIR-COOLED LIQUID CHILLER

30GX AIR-COOLED LIQUID CHILLER

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

RCD Air Cooled Condensing Unit (50/60 Hz)

COMPRESSOR TECHNICAL DATA

Low Air Process Room. Chiller Series. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

COMPRESSOR TECHNICAL DATA

CWP-CO / CWP-RC / CWP-HP 02 to 35

LOW AIR / DUAL THROW UNIT COOLER. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW

CATÁLOGO TÉCNICO COMERCIAL

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

YH Series Scroll Compressors With Dual-Compliance For A/C and Chiller

DTS 3000 Cooling Units Watt

Küba Green Line XXXXXXXXXX. Küba market plus SP. High Performance Unit Cooler.

Heat Exchangers. Evaporator Catalogue

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

Product Catalog TSE Series Scroll Central Chillers

Innovative Engineering. Catalogue. Condenser. ECU, ECV and ECW Industrial Condenser Series. Technical Brochure

CGA CXA VGA VXA CG-PRC006-E4

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller

AIR COOLED CHILLERS WATER COOLED CHILLERS

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

AC centrifugal fan. forward curved, dual inlet with housing (flange)

Product Catalog TSE Series Scroll Central Chillers

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE

DIMENSION AND SELECTION GUIDE

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

InvoTech. YH series Scroll Compressors. Special Design For A /C and Chiller

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

Condensers. 7 kw 198 kw.

Unit Report For CH-1 30RB070 Project: UNF Soccer Stadium 04/21/2017

AC centrifugal fan with housing (small flange)

5 to 100 Ton Capacity Custom Capacities Available

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

Part Ⅰ : Technical Information

technical data Systems RSX(Y)P-K7W1 Inverter cooling only / heat pump series

Operators Manual. Recirculating Chiller /06/08

COMPRESSOR TECHNICAL DATA

COMPRESSOR TECHNICAL DATA

SeasonPak Packaged Air-Cooled Water Chiller

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension

LUI / LUO. Condensing Units

Product Data Sheet HKK70VSD Revision 1 (Variant Code E)

Shandong Vicot Air Conditioning Co.,Ltd. Air Cooled Condensing Unit

Series P215ST Single Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Küba Green Line XXXXXXXXXX. Küba market plus SP. High Performance Unit Cooler.

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

REMOTE AIR COOLED CONDENSERS RC-C Series & DV/DH Series

Ductable water unit FWD UNT-PRC002-E4

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

NEOSTAR NEW! Condensers. www. 18 kw 1250 kw

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

Stylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

AC centrifugal module - RadiCal

Alfa Laval Optigo CC. Commercial air coolers - Single discharge

CONTINUOUS CAPACITY CONTROL MODELS

Cubic unit cooler. SKB semi-industrial range

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Cubic unit cooler. SKB semi-industrial range

KEH-Line Condensing Units

ROOFMASTER STEF ROOF FAN

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

1/8 Ton J Series. Ship Loose Options: UL 1995 certification 18 month parts & labor warranty 24/7 service & support

Enhanced Air Conditioning

InvoTech. YH series Scroll Compressors. Special Design For A /C and Chiller

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils

Unit Report For CH-1 Replacement Project: Marlboro County High School Chiller Replacement 10/22/2018

InvoTech. YH series Scroll Compressors. Special Design For A /C and Chiller

technical data air conditioning systems RXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

CFFWA Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 12,000-60,000 BTUH

OPEN DISPLAY MERCHANDISER Commercial refrigerator Service Manual

technical data air conditioning systems MXS-B Multi Application Split Sky Air

MCE4 MCE4. Electric Heating / Electric Cooling Packaged Thru-the-Wall Units

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH

FC SERIES FLUID COOLERS THE LEADER IN THE INDUSTRY FOR ALL YOUR HVAC NEEDS. Replacement Coils Heat Exchangers Fan Coils

Transcription:

CACC condensers CDCC dry coolers range 71 1036 Characteristics -cooled CACC-condensers and CDCC-dry coolers are suitable for outdoor use equipped with weather protected safety switches for every fan. 16 unit sizes and 5 different fan rotation speed options. Two mounting alternatives: * H-type with air upwards * V-type with horizontal air Accessories * Frequency controller applied safety switches and cables * Water jet system to increase capacity during short loading peaks * Painted casing * Special heat transfer materials * Electrical board for fan motor(s) and automated control centre. Technical data Heat transfer section is made of copper tubes and aluminium fins. Standard fin spacing is 2,5 mm, with 2,0 mm spacing also available. Frame is constructed of efficient corrosion protected hot-galvanised steel. Legs height is adjustable between 400-760 mm. Fan motors are high efficiency external ring motors with protection class IP 54. Units are provided with partition walls between fan sections. Condensers have neutral gas charge for preinstallation period. Unit selection The appropriate dry cooler can be selected using a special selection program available to our salesman. The appropriate condenser can be selected by the same program, or by using the leaflet tables.

Product designation C x C C - yyyyy - zzz - aaa - b - ccc - ddddd - f X : A = condenser D = dry cooler y : unit size z : rotation speed a : fin step (2,5 or 2,0 mm) b : air direction ( H=vertically upwards; V=horizontally) c : condenser circuits d : condenser tubing / multicircuited dry cooler s passes f : accessories (D=water jet system; F=metallic safety switch; G=F+clixon ) Fan motors electrical data ROTATION SPEED ( code zzz ) Power input / fan [ ] 0,21 0,47 0,95 1,4 2,5 Nominal amps / fan [ A ] ( 1 ) 0,65 1,0 1,8 2,7 5,8 Max amps / fan [ A ] ( 2 ) 0,8 1,2 2,2 3,2 7,0 Mains 400 V 50 Hz 3 Ph Notes: ( 1 ) : Nominal amps +40 o C air condition. ( 2 ) : Max amps -30 o C ambient air condition. Motors overload protection must be calculated on the basis of motor s max amps data! Overload protectors should have +/- 20% adjustting margin for possible motor(s) performance changes. Performance data Page 3 values are given for conditions listed below: * pressure at 10 m s distance from unit end (by ISO 3741 standard) *Fin step 2,5 mm *Condensing capacity by condensing temperature + 45 o C, ambient air +30 o C and refrigerant R134a or R404a. *For dry coolers ambient air +30 o C, liquid temperatures +42/+36 o C, 35 % ethylene glycol mixture.

data Condensers CACC ( ambient air +30 o C, condensing temp. +45 o C and refrigerant R134a ) Rotation speed ( code zzz ) Unit size Fan placing and amount 112 1 x 2 71 5,2 35 86 6,7 40 105 8,9 44 123 11,5 53 146 16,3 62 212 1 x 2 76 4,9 35 95 6,4 40 117 8,5 44 140 11,0 53 170 15,3 62 313 1 x 3 107 7,8 36 129 10 41 157 13,3 45 184 17,2 54 218 24,5 64 413 1 x 3 115 7,3 36 143 9,6 41 175 12,7 45 210 16,5 54 256 23,0 64 514 1 x 4 143 10,4 37 172 13,4 42 210 17,8 46 246 23,0 55 292 32,6 65 614 1 x 4 153 9,8 37 190 12,8 42 234 17,1 46 280 22,0 55 341 30,6 65 715 1 x 5 178 13,0 38 215 16,7 43 262 22,2 47 307 28,7 56 364 40,8 66 815 1 x 5 191 12,2 38 238 16 43 292 21,2 47 350 27,5 56 426 38,3 66 926 2 x 3 204 15,0 39 247 19,8 44 302 26,4 48 352 33,9 57 437 48,9 67 1026 2 x 3 220 14,4 39 274 18,9 44 335 24,9 48 396 32,4 57 512 46,0 67 1128 2 x 4 272 20,0 40 330 26,4 45 403 35,2 49 469 45,2 58 557 64,0 68 1228 2 x 4 294 19,2 40 365 25,2 45 446 33,2 49 528 43,2 58 636 57,8 68 13210 2 x 5 340 25,0 41 412 33,1 46 502 44,1 50 583 56,5 59 697 80,0 70 14210 2 x 5 367 24,0 41 457 31,5 46 558 41,5 50 661 54,0 59 796 72,3 70 15212 2 x 6 408 30,0 41 494 39,6 46 603 52,8 50 700 57,8 59 835 96,0 71 16212 2 x 6 440 28,8 41 548 37,8 46 670 49,8 50 793 64,8 59 958 86,7 71 Dry coolers CDCC ( ambient air +30 o C, liquid temp. +42/+36 o C, liquid 35 % ethylene glycol) Rotation speed ( code zzz ) Unit size Fan placing and amount 112 1 x 2 44 5,2 35 53 6,7 40 65 8,9 44 76 11,5 53 91 16,3 62 212 1 x 2 47 4,9 35 59 6,4 40 73 8,5 44 87 11,0 53 106 15,3 62 313 1 x 3 66 7,8 36 80 10 41 98 13,3 45 114 17,2 54 135 24,5 64 413 1 x 3 71 7,3 36 87 9,6 41 109 12,7 45 130 16,5 54 159 23,0 64 514 1 x 4 89 10,4 37 107 13,4 42 130 17,8 46 153 23,0 55 181 32,6 65 614 1 x 4 95 9,8 37 118 12,8 42 145 17,1 46 174 22,0 55 212 30,6 65 715 1 x 5 110 13,0 38 134 16,7 43 163 22,2 47 191 28,7 56 226 40,8 66 815 1 x 5 119 12,2 38 148 16 43 181 21,2 47 217 27,5 56 264 38,3 66 926 2 x 3 127 15,0 39 153 19,8 44 187 26,4 48 218 33,9 57 271 48,9 67 1026 2 x 3 135 14,4 39 170 18,9 44 208 24,9 48 246 32,4 57 218 46,0 67 1128 2 x 4 169 20,0 40 205 26,4 45 250 35,2 49 291 45,2 58 346 64,0 68 1228 2 x 4 183 19,2 40 226 25,2 45 277 33,2 49 328 43,2 58 394 57,8 68 13210 2 x 5 211 25,0 41 256 33,1 46 311 44,1 50 362 56,5 59 432 80,0 70 14210 2 x 5 228 24,0 41 283 31,5 46 346 41,5 50 410 54,0 59 494 72,3 70 15212 2 x 6 253 30,0 41 306 39,6 46 374 52,8 50 434 57,8 59 518 96,0 71 16212 2 x 6 273 28,8 41 340 37,8 46 415 49,8 50 492 64,8 59 594 86,7 71 Note! Dry cooler capacity depends of selected passes number. Concrete selections are available by selection program.

Dimensions ( Aimed dimensional drawings are available by supplier ) Upwards ( H-type ) Dimensions [ mm ] Weight Internal volume Size A B C D E1 E2 E3 E4 [ kg ] [ l ] 112 2502 1928 1290 1882 2128 0 0 0 427 49 212 2502 1928 1290 1882 2128 0 0 0 469 66 313 3602 1928 1290 1882 3220 0 0 0 617 73 413 3602 1928 1290 1882 3220 0 0 0 684 100 514 4702 1928 1290 1882 2175 2153 0 0 818 99 614 4720 1928 1290 1882 2175 2153 0 0 904 129 715 5802 1928 1290 1882 2175 3253 0 0 1018 117 815 5802 1928 1290 1882 2175 3253 0 0 1132 159 926 5702 2328 1290 2279 1775 3553 0 0 1138 142 1026 5702 2328 1290 2279 1775 3553 0 0 1270 192 1128 6902 2328 1290 2279 3275 3245 0 0 1435 171 1228 6902 2328 1290 2279 3275 3245 0 0 1596 231 13210 8565 2328 1290 2279 1625 3300 3245 0 1794 210 14210 8565 2328 1290 2279 1625 3300 3245 0 1995 285 15212 10217 2328 1290 2279 1625 3300 3298 1595 2152 259 16212 10217 2328 1290 2279 1625 3300 3298 1595 2394 324

Dimensions ( Aimed dimensional drawings are available by supplier ) Horizontal ( V-type ) Dimensions [ mm ] Weight Internal Size A B C E1 E2 [ kg ] volume [ l ] 112 2502 1200 1940 2120 0 427 49 212 2502 1200 1940 2120 0 469 66 313 3602 1200 1940 3220 0 617 73 413 3602 1200 1940 3220 0 684 100 514 4702 1200 1940 2175 2145 818 99 614 4720 1200 1940 2175 2145 904 129 715 5802 1200 1940 2175 2145 1018 117 815 5802 1200 1940 2175 2145 1132 159 Marketing CHILLER OY reserves the right to changes without prior notice. CHILLER OY Louhostie 2, FIN-04300 TUUSULA Phone +358-9-274 7670 Fax +358-9-274 767 77 www.chiller.fi info@chiller.fi