Troubleshooting. CryoSmart 1 - CryoSmart 20

Similar documents
SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

ECscan10H Pocket Conductivity Tester. Instruction Manual BANTE INSTRUMENTS LIMITED

Manual KREBS Viscometer PCE-RVI 5

PANcharge1k Battery Charger User's Manual

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Temperature Controller OVATION 214 User's Guide

TRITON ERROR CODES ERROR CODE MODEL SERIES DESCRIPTION RESOLUTION

TR22F Repair Manual (Electronics)

Inlet Controller SB3500 USER'S MANUAL

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

ORPscan20 Pocket ORP Tester Instruction Manual

ECscan40 Pocket Conductivity/TDS/Salinity Tester Instruction Manual

T621 Repair Manual (Electronics)

T611 Repair Manual (Electronics)

AFT mid drive kit Trouble shooting guide For 24v to 48V Kelly Controller KBS 48101L-L 100 A peak

Electronic Ballast EVG 2000-T

ECscan20 Pocket Conductivity Tester Instruction Manual

TROUBLESHOOTING TP. Index

BIM-17-2 Bus Interface Module for compass and outside temperature

Bante220 Portable ph Meter Instruction Manual

TDSscan10M Pocket TDS Tester Instruction Manual

Index. Index...pag.1. General features...pag.2 Mechanical features Available size. Electrical features pag.3 Protections Signalling Led

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

FULL AUTOMATIC ASPHALTENE ANALYZER APD-500A USER S GUIDE

PHscan30S Pocket ph Meter Instruction Manual

Features: Enhanced throttle response, excellent acceleration, linearity and driveability

Service Manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta

Astor 20 Colony Counter User s Manual

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

KANEAUTO 4-4 & KANE AUTO 5-4

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

Model 1:8 Beast-ZTWSS120A 1:8 Beast-ZTWSS150A. PN#Model Cont.Current 120A 150A. Burst Current 760A 1080A

PROBLEM SOLVING GUIDE ELMECO SLUSH MACHINE MODEL FCM

Furnace Web Site FAQs. Pro Press 100 / Pro 100 / Pro 100 plus. Lift. Belt Noise

MONITOR INSTALLATION AND OPERATING INSTRUCTIONS VERSION

1. INTRODUCTION AND SYSTEM DESCRIPTION BLOCK DIAGRAM GENERAL INFORMATION GLOSSARY... 7

XK3190- A7. Weighing indicator USER MANUAL

Using the LCT100 for Load Cell Troubleshooting

ECscan30 Pocket Conductivity/TDS Tester Instruction Manual

Model TUR-200D Turbine Flowmeter

Barrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind)

IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL

RD712 & RD712XL Remote Displays. Model 615 / 615XL Indicator User s Manual

LAMBDA SENSOR CONTROLLER

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

COMPONENT WORK SAMPLE 15 Electrical Circuitry & Print Reading MAINTENANCE MANUAL

Mini Multimeter with Non-Contact Voltage Detector (NCV)

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

INSTALLATION/OPERATION

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

Temperature Controller. TC5+2V4SA Plus USER'S MANUAL

Breezair TBA 550 Installation Manual

USER MANUAL BRUSHLESS SPEED CONTROLLER S5-RTR ESC S5A-RTR ESC RC CARS & TRUCKS

OPERATION MANUAL Common for All models Bobbin Sensor (Weft End Detection) DP150 - L2 BP150 - L2-12V BP150 - L2-24V (PNP/NPN)

PHscan10S Pocket ph Tester Instruction Manual

Battery Management Innovation. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

Intelligent torque meter tester

OD DIGITAL DISSOLVED OXYGEN CONTROLLER POLAROGRAPHIC CELL

Service instructions. MAGNA Series 2000

OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13

OD DISSOLVED OXYGEN METER

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Table of Contents. General Information...1. Components...2. Connection...4

AC drive has detected too high a Check loading

TURBODYNO **WARNING**

Temperature multi-function calibrator Model CTM

Features: Enhanced throttle response, excellent acceleration, strong brakes and throttle linearity. Using LED program card to make adjustments.

Signature Series. Duplex Softener Service Manual

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT

BATTERY ELECTRICAL SYSTEM ANALYSER BESA 11. Figure 10

Installation & Operating Manual

HanTron Model HT-3P. Manual. Installation Maintenance Repair Manual

WalkLAB Digital Dissolved Oxygen meter HD9030

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

POSITIVE DISPLACEMENT FLOWMETER

NDJ Series Product Standard: Q/SGKW5 SNB Series Product Standard: Q/SGKW6. Operation Manual for NDJ Series and SNB Series Digital Viscometer

SWING GATE OPENER SW300 SERIES

Pressure chlorine changeover unit C 7520

Operating Instructions. Angle Seat Control Valve. Type 7020

Operating Manual. Operating Manual HYBRIDIZATION INCUBATOR. combi-h12 combi-d24 combi-v12 combi-sv12 combi-sv120

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Care and use guide. Contents. page

Modern Applied Science

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

KCR1. Kiln Controller Handbook. Kilncare Ltd. The Kiln Works 907 Leek New Road Baddeley Green Stoke-on-Trent Staffordshire, ST2 7HQ United Kingdom

SmarTire TPMS Maintenance Hand Tool. Revision User Manual

For additional information, please visit our website at SENSOR SPECIFICATIONS

DIGITAL RCD(ELCB) TESTER

INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3. Operating Instructions for DORNIER looms. Robustness Reliability Quality Productivity Versatility

TL4076 Top 5 Tips Get to know your TL4076

TE-HUD User Manual. l ::: J TECH SUPPORT. MetraDealer.com

Cannondale Diagnostic Tool Manual

Atomic Absorption Spectroscopy

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM,

TECHNICAL CHARACTERISTICS: Structure : upright type, realized in sheet steel epoxy coated white colour both in- and outside or in stainless steel

Transcription:

Troubleshooting CryoSmart 1 - CryoSmart 20 ASTORI TECNICA di Astori Claudia & C. s.n.c. - Via Stelle, 11-25020 Poncarale (BS) - Italy Phone no.: +39 030 2540240 - Fax no.: +39 030 2640812 E-mail: info@astorioscar.com - www.astorioscar.com

Troubleshooting CryoSmart 1 - CryoSmart 20 ASTORI SERVICE DEPARTMENT... 4 CHAPTER 1 PROBLEMS AND SOLUTIONS 5 THE INSTRUMENT RETURNS SAMPLE FAILED.. 5 THE INSTRUMENT RETURNS TIME OUT.. 5 THE INSTRUMENT DOES NOT RUN THE ANALYSIS.... 6 BAD REPEATABILITY OF THE INSTRUMENT.. 6 THE INSTRUMENT UNDERVALUES THE SAMPLES.. 7 THE INSTRUMENT OVERVALUES THE SAMPLES. 7 THE FUSES BLOW.. 7 INSUFFICIENT TEMPERATURE OF THE BATH (WAIT ). 8 THE CAROUSEL DOES NOT ROTATE (CryoSmart 20)...... 8 WITH THE SAMPLING TUBE LOADED, THE HEAD DOES NOT GO DOWN. 8 THE HEAD DOES NOT MOVE.. 9 THE STIRRER DOES NOT WORK... 9 THE STIRRER BREAKS THE SAMPLING TUBES 9 THE INSTRUMENT DOES NOT PRINT ANY DATA... 10 CHAPTER 2 ADJUSTMENTS 11 THERMISTOR ADJUSTMENT. 11 2

STIRRER ADJUSTMENT. 12 AGITATION ADJUSTMENT. 13 FREEZING STROKE ADJUSTMENT. 14 CORRECT POSITION OF THE PHOTOCELL (CryoSmart 20)..... 16 THERMISTOR REPLACEMENT. 17 CHAPTER 3 ANALYSIS AND CALIBRATION... 18 ANALYSIS 18 CALIBRATION 19 CHAPTER 4 INSTRUMENT.. 21 PARTS.. 21 BLOCK DIAGRAM.. 23 FRONT PANEL... 24 REAR PANEL.. 25 BATH 26 SPRING 27 HEAD 29 MANDREL 30 MOTOR (CryoSmart 20)........ 30 PUMP 31 FILTER. 33 ACTUATOR. 33 BOARD. 34 FAN... 36 PRINTER COMMUNICATION.. 36 FUSES.. 37 FEATURES.. 37 3

ASTORI SERVICE DEPARTMENT In case of any trouble, please contact our SERVICE DEPARTMENT at the telephone number: +39 030 2540240, fax number +39 030 2640812 or by e-mail at: service@astorioscar.com. This manual was made to clarify the most frequent troubles and how to solve the problems occurring to our cryoscopes, when our technical assistance is not necessary. In this manual you will find lots of possible causes describing problems, evaluated by the technical assistance. Detailed descriptions are listed, problem by problem, along with clear explanations about how to solve them. However, please do not hesitate to call us in case of any problem you might find; moreover, we would like to remind you that all our cryoscopes include a 12-month warranty period starting from the purchase date. Kind regards. Astori Tecnica s.n.c. 4

CHAPTER 1 - PROBLEMS AND SOLUTIONS THE INSTRUMENT RETURNS SAMPLE FAILED Problem: The result of the analysis is SAMPLE FAILED. Causes: 1. The freezing stroke is not strong enough for milk samples. 2. Thermistor failure (or not connected). Solutions: 1. Adjust the freezing stroke (see Freezing Stroke Adjustment ). 2. Check the connections of the thermistor. 3. Replace the thermistor. -- If you press the head goes down and immediately the instrument makes the freezing stroke : check the connections of the thermistor and/or replace it. THE INSTRUMENT RETURNS TIME OUT Problem: The result of the analysis is TIME OUT. Causes: 1. The analyzed sample is too cold. 2. The milk is altered (high presence of salts, urea, etc.). 3. The temperature of the bath is too high or too low. 4. The agitation is too strong and air bubbles are created inside the sample; the sample is freezed before 3 C. 5. The volume of the cooling liquid is not enough. 6. The carousel did not rotate (CryoSmart 20). 7. The magnet is disconnected (see Head ). Solutions: 1. Check the temperature of the milk sample. Too cold samples freeze before the freezing stroke. 2. Verifiy, using other methods, if the milk sample has been altered. 3. Check the temperature of the bath: -7 C ± 0.5 C. 4. Adjust the agitation (see Agitation adjustment ). 5. The sample tubes must be clean: please, check for it. The pump must replace the liquid at the end of every analysis, and the filter must be clean (see Bath, Filter and Pump ) 6. Check the correct rotation of the carousel or the spring position (see Spring ). 7. Check the magnet connections. 5

THE INSTRUMENT DOES NOT RUN THE ANALYSIS Problem: During an analysis, the temperature of the sample is the same one of the bath, but no error is displayed. Causes: 1. The lower microswitch is not correctly pressed. Solutions: 1. Check the lower microswitch inside the actuator. BAD REPEATABILITY OF THE INSTRUMENT Problem: The instrument does not show a good repeatability. Causes: 1. Altered samples. 2. Bad adjustment of the agitation. 3. Bad adjustment of the freezing stroke. 4. Wrong temperature of the bath. 5. Wrong position of the thermistor. 6. Broken thermistor or bad connections. Solutions: 1. Check the integrity of the samples. 2. Adjust the agitation (see Agitation Adjustment ). 3. Adjust the freezing stroke (see Freezing Stroke Adjustment ). 4. Check the entire fluidic system. Check the tubes (they must be clean); check the pumping system; check the liquid inside the tank (see Rear Panel ), check the filter (replace it, if necessary). 5. Check the position of the thermistor (see Thermistor Adjustment ). 6. Check the fixing of the thermistor. 7. Check the connections or replace the thermistor. 6

THE INSTRUMENT UNDERVALUES THE SAMPLES Problem: The result of the analysis is undervalued. Causes: 1. The sample is too cold. 2. The freezing stroke is too weak. 3. The thermistor is broken. Solutions: 1. Check the milk temperature. 2. Adjust the freezing stroke (see Freezing stroke adjustment ). 3. Replace the thermistor. THE INSTRUMENT OVERVALUES THE SAMPLES Problem: The result of the analysis is overvalued. Causes: 1. The thermistor is broken. Solutions: 1. Replace the thermistor. THE FUSES BLOW Problem: When you switch the instrument on, the fuses blow. Causes: 1. Diodes bridge failure. 2. Power supply failure. Solutions: 1. Check the diodes bridges. 2. Check the power supply system. 7

INSUFFICIENT TEMPERATURE OF THE BATH (WAIT ) Problem: The instrument does not keep the working temperature. Causes: 1. Cooling bath failure. 2. Cooling bath control system failure. Solution: 1. Check the cooling bath (Peltier cell). 2. Check the T2 (IRF540) MOSFET transistor. THE CAROUSEL DOES NOT ROTATE (CryoSmart 20) Problem: When you press the carousel does not rotate. Causes: 1. Rotation system failure. 2. The microswitch is not correctly pressed. Solutions: 1. Check the correct functionality of the rotation system (mechanical and electrical). 2. Check the correct functionality of the microswitches inside the actuator. WITH THE SAMPLING TUBE LOADED, THE HEAD DOES NOT GO DOWN Problem: The tube is inside the duct but the head does not come down. Causes: 1. Wrong position of the photocell. 2. Photocell failure. Solutions: 1. Check the position of the photocell (see correct position of the photocell ). 2. Replace the photocell. 8

THE HEAD DOES NOT MOVE Problem: The head does not move but the photocell is in a correct position. Causes: 1. Microswitches failure. 2. Actuator failure. Solutions: 1. Check the microswitches. 2. Check the actuator. THE STIRRER DOES NOT WORK Problem: The stirrer does not work. Causes: 1. Magnet failure. Solutions: 1. Check the magnet connections. THE STIRRER BREAKS THE SAMPLING TUBES Problem: The stirrer breaks the sampling tubes. Causes: 1. The freezing stroke is too strong. Solutions: 1. Adjust the freezing stroke (see freezing stroke adjustment ) 9

THE INSTRUMENT DOES NOT PRINT ANY DATA Problem: The instrument does not print the results of the analyses or the parameters. Causes: 1. Communication failure. Solutions: 1. Check the connections of the printer (see Printer communication ). 10

CHAPTER 2 - ADJUSTMENTS THERMISTOR ADJUSTMENT The correct position of the thermistor is showed here below. The glass ball of the thermistor must be at the center of the semisphere and at 35,5 mm from the mandrel. 1 4 2 3 1. Mandrel 2. Tube 3. Thermistor 4. Stirrer If the position is not correct, please follow this procedure: 1. Unscrew the screw with the hexagonal socket in its head that fixes the thermistor at the mandrel. 2. Place the thermistor in the correct position. 3. Fix the thermistor at the mandrel. 4. Check the clamping of the thermistor. 11

MANDREL HEX KEY STIRRER ADJUSTMENT The stirrer and the thermistor have to be at the same level (see Thermistor adjustment ). The stirrer must be centered like shown in the picture here below, and it must vibrate symmetrically and freely inside the slot (see mandrel and see head ). 1 2 4 3 1. Mandrel 2. Thermistor 3. Slot 4. Stirrer 12

AGITATION ADJUSTMENT The agitation must avoid the production of air bubbles inside the tube. This adjustment procedure can be made by using a calibration standard. In perfect working conditions, the maximum stirrer amplitude is 2-3 mm when the stirrer itself is properly placed inside the calibration standard. To check the agitation strength, please follow this procedure: 1. Enter the main menu by pressing. 2. Search for Agitation Test. 3. Press. 4. Fill a tube with a calibration standard up to the level (volume) normally used with a sample during a common analysis. 5. Place the tube under the mandrel (as a normal analysis should be performed). 6. Press to start the test, press to finish the test. -- If the agitation looks too strong or too weak, follow these steps: 1. Enter the main menu by pressing. 2. Search for Agitation Amplitude. 3. Increase or decrease the value by pressing. CORRECT 13

WRONG FREEZING STROKE ADJUSTMENT The correct freezing stroke must: hit the walls of the tube, stir all the liquid, avoid the breakage of the tubes. To adjust the freezing stroke, please follow this procedure: 1. Enter the main menu by pressing 2. Search for Stirrer Test. 3. Press. 4. Fill a tube with a calibration standard up to the level (volume) normally used with a sample during a common analysis. 5. Place the tube under the mandrel (as a normal analysis should be performed). 6. Press to start the test, press to finish the test. 7. Run a lot of tests to check if the undesired possibility to break a tube exists. -- If during a test the stirrer breaks a tube, proceed like described here below: 1. Enter the main menu by pressing. 2. Search for Stirrer Test. 3. Press. 4. Press to start the test. 5. Unlock the adjustment trimmer (see Rear panel ). 6. Decrease the value by turning it anticlockwise. 7. Lock the trimmer again. 14

8. Press. 9. Run some new tests to check for the undesired possibility to break a tube. -- If the freezing stroke is too weak, follow the steps here below: 1. Enter the main menu by pressing. 2. Search for Stirrer Test. 3. Press. 4. Press to start the test. 5. Unlock the adjustment trimmer (see Rear panel ). 6. Increase the value by turning it clockwise. 7. Lock the trimmer again. 8. Press. 9. Run some new tests to check for the undesired possibility to break a tube. LOCKING SYSTEM TRIMMER 15

CORRECT POSITION OF THE PHOTOCELL (CryoSmart 20) The correct position of the photocell is described in the next pictures. The photocell must point over the semisphere. 16

THERMISTOR REPLACEMENT To replace a thermistor, please follow the procedure as described here below: 1. Disconnect the instrument from the main supply. 2. Open the head. 3. Unscrew the screw (the one with the hexagonal socket in its head) that fixes the thermistor at the mandrel (see Thermistor Adjustment ) 4. Get the soldered cables free from their insulation coats (see Head ). 5. Unsolder the thermistor cables. 6. Extract the thermistor from the mandrel by pulling it down. 7. Insert the new thermistor from the bottom of the mandrel. Please, pay attention! Do not hit the thermistor glass ball. 8. Solder the cables of the new thermistor. Check that the new solders are done correctly. 9. Insulate the solders. 10. Check the thermistor position (see Thermistor Adjustment ). 11. Fix the thermistor. 12. Fix the cables of the thermistor; be careful not to tend them and not to place them too close to the stirrer and/or the magnet. (see Head ) 13. Close the head. 14. Proceed with a new calibration procedure (see Calibration ). 17

CHAPTER 3 - ANALYSIS AND CALIBRATION ANALYSIS The correct analysis of the cryoscopic point should respect the following curve: 1 2 4 3 1. Start analysis 2. Agitation 3. Freezing stroke 4. Plateau 18

CALIBRATION Before running each calibration procedure, check the condition of the calibration standards. Gently turn the bottle upside down and rotate it several times to mix its content thoroughly. The standard solutions should not be used if the bottle is filled for less than one quarter in comparison to its total capacity. The shelf life of the standards covers 12 months from the date of production. To perform a correct calibration procedure, please follow the instructions here below: 1. Enter the main menu by pressing the button. 2. Search for Calibration Reset. 3. Press the button. 4. Press again to confirm. 5. Clean the mandrel, the thermistor and stirrer with a piece of soft paper. 6. Prepare 1 sample of the - 0.408 C calibration standard. 7. Start the analysis by pressing. 8. Wait until the end of the analysis and press the button. 9. Press. 10. Press to confirm the calibration. 11. Clean the mandrel, the thermistor and the stirrer with a piece of soft paper. 12. Prepare 1 sample of the - 0.600 C calibration standard. 13. Start a new analysis by pressing. 14. Wait until the end of the analysis, then press the button. 15. Press. 16. Press. 17. Press again to confirm. Now, a new calibration procedure is necessary. Repeat the operations from step 5 to 17 using 3 replicates for each calibration standard. Check the repeatability of the values: if the repeatability is bad, check the thermistor for any breakage; maybe, it requires a replacement. After finishing the calibration procedure, run a new analysis with 5 replicates of the - 0.512 C calibration standard. 19

-- If the repeatability of the 5 replicates looks good but the value is different from - 0.512 C, follow this procedure: 1. Enter the main menu by pressing. 2. Select To Linearize. 3. Increase or decrease the value if the results are overvalued or undervalued using the buttons. Any variation of ± 5 on Linear means ± 0.001 C. Example: VALUE READED LINEARITY MODIFY NEW VALUE -0.513 C -15 +5-10 -0.510 C +10-10 0 4. Switch the instrument off and on if you change the linearity value. 20

CHAPTER 4 - INSTRUMENT PARTS -- CryoSmart 1 5 1 6 2 7 3 4 8 1. Mandrel 2. Thermistor and Stirrer 3. Duct 4. Front panel 5. Head 6. Actuator 7. Rear Panel 8. Grate 21

-- CryoSmart 20 1 2 3 7 4 5 8 6 1. Head 2. Mandrel 3. Actuator 4. Carousel 5. Rear Panel 6. Grate 7. Thermistor and Stirrer 8. Front Panel 22

BLOCK DIAGRAM STEP MOTOR (CryoSmart 20) ACTUATOR DISPLAY PELTIER CELL PERISTALTIC PUMP PROGRAM MEMORY CPU STIRRER FLASH MEMORY RS232 PHOTOCELL (CryoSmart 20) NTC PT100 MICRO SWITCHES BUTTONS POWER SUPPLY FAN 23

FRONT PANEL 1 2 5 3 6 4 1. Display 2. MENU 3. CAL / ESC 4. DOWN / 5. START-STOP / OK 6. UP / The keys have two different colours: the white side runs the operational functions of the instrument; the orange side allows the visualization and modification of the functions after entering the MENU. The button allows to enter and to scroll through the functions. It allows to scroll through the calibration menu. The START-STOP / OK key is used to start or stop the analysis. Pay attention: put the sample first and then press START. When the START key is pressed and the analysis has started, the display shows the sample temperature, the reference value to calculate the added water percentage and, after the freezing stroke has done, the added water percentage of the sample. The START-STOP key is also used to give confirmations (OK) and it allows to enter and confirm the functions of the menu. The CAL/ESC key (when used as ESC) allows to exit the functions of the menu. When used as CAL, it allows the calibration of the instrument. The keys releasing the proper key. are used to manually lower and raise the head, by pressing and 24

REAR PANEL 1 2 7 3 8 4 9 5 10 6 11 1. Automatic refilling tube 2. Filter 3. Trimmer 4. Data input (Program) 5. Printer 6. Cooling liquid tank 7. Waste 8. Main switch 9. Fuses compartment 10. Supply connector 11. Peristaltic pump 25

BATH The bath is cooled by means of a Peltier cell (+15 V AC) at 7 C ± 0.5 C. 1 2 3 1. Duct 2. Cooling bath body 3. Cooling system The replacement of the liquid inside the bath is possible by: the external bottle, the peristaltic pump and the waste tube. When the instrument is turned on, the refilling of the bath is performed automatically. At the end of every analysis, the cooling liquid is completely replaced thanks to the circuit, just described. 26

PUMP FILTER COOLING BATH WASTE DUCT BOTTLE The temperature control in the bath is realized like in the figure below. The PT100 probe sends data to the electronic control board, directly. A PID controller pilots the MOSFET transistor IRF540. The fan system gets the heat (produced by the Peltier cell) out of the equipment. (see Fan ). 27

SPRING Inside the cooling bath there is a spring for the sample tube. Pay attention! The spring must be positioned in the duct exactly as described in the picture below. -- CryoSmart 1: UP -- CryoSmart 20: The spring must be at the same level of the bath's duct. -- If the spring is positioned higher than the duct, probably will be dragged by the tubes. -- If the spring is too low, probably will prevent the carousel rotation. SMALL DIAMETER UP BIG DIAMETER 28

HEAD Inside the head there are the following components: the magnet, the lamina who allows the stirrer swing, and the connections of the thermistor. 1 6 7 2 3 8 4 7 5 9 1. Lamina 2. Magnet 3. Stirrer support 4. Thermistor cables 5. Head 6. Centering nut 7. Magnet clamper 8. Stirrer cables 9. Mandrel To center the stirrer, please follow this procedure: 1. Unscrew the nuts and move the lamina until the stirrer is in the correct position. (see Stirrer Adjustment ). 2. Screw the nuts again. One method to adjust the Freezing Stroke and the agitation is by moving the magnet: Unscrew the screw (the one with the hexagonal socket in its head) that clamps the magnet, in order to approach and move away the magnet from the stirrer support. 1. By moving the magnet closer, the freezing stoke becomes gentler and its working quality improves, but the agitation becomes too strong. 2. By moving the magnet away, the agitation works better, but the freezing stroke increases its power and a breakage of the sample tubes becomes possible. Find the better position where both agitation and freezing stroke work correctly. Then clamp the magnet again. After finishing these operations, adjust the agitation and the freezing stroke. (see Agitation Adjustment and Freezing Stroke Adjustment ). 29

MANDREL The thermistor and the stirrer are located inside the mandrel. MOTOR (CryoSmart 20) The step motor moves the carousel. 30

PUMP The pump is the element that allows the refilling of the liquid inside the cooling bath. CLIP B CLIP A CLIP A CLIP B If the pump is dirty, an insufficient volume of liquid may be replaced inside the bath. To clean and replace the tube, please follow this procedure: 1. Release the pump by pressing the A clips. 31

2. Open the pump by pressing the B clips. 3. Replace the tube. 32

FILTER If the filter is dirty, the cooling liquid cannot fill the cooling bath properly, so that the results may be inaccurate. Replace the filter when decribed. Pay attention! Place the filter in the right position. The arrow (on the filter body) must be addressed upfront. UP ACTUATOR The actuator is the component that moves the head up and down. The microswitches are located inside the actuator. 33

BOARD The board allows all the following operations: 1. Move the head. 2. Rotate the carousel. 3. Read data from the photocell. 4. Control the cooling bath. 5. Pilot the stirrer. 6. Read data from the thermistor. 7. Communicate with the printer. 8. HMI (Human Machine Interface). 1 8 J2 9 11 12 61 15 16 17 18 60 21 22 57 56 59 58 25 26 29 55 50 49 IRF540 46 45 44 43 42 38 41 39 37 34 33 30 # PIN PIN Name Type # Connection 1 Photocell A IN 3 2 Photocell B IN 4 3 Photocell +12 V OUT 5 4 Photocell GND OUT 6 5 NC - - 6 Microswitch Common IN 7 7 Microswitch Up IN 8 8 Microswitch Down IN 9 9 NC - - 10 NC - - 11 NC - - 34

12 Step Motor IN 10 13 Step Motor IN 11 14 Step Motor IN 12 15 Step Motor IN 13 16 9 V ~ AC (step motor) IN 14 17 9 V ~ AC (step motor) IN 15 18 NC - - 19 NC - - 20 NC - - 21 NC - - 22 + Actuator OUT 16 23 - Actuator OUT 17 24 12 V ~ AC (actuator) IN 18 25 12 V ~ AC (actuator) IN 19 26 9 V ~ AC (pump) IN 14 27 9 V ~ AC (pump) IN 15 28 + Pump OUT 20 29 - Pump OUT 21 30 GND IN 22 31 Peltier Control OUT 23 32 NC - - 33 +12 V Peltier IN 24 34 Relè Stirrer OUT 25 35 Relè Stirrer OUT 26 36 NC - - 37 NC - - 38 NC - - 39 0 V transformer (stirrer) IN 27 40 GND stirrer IN 28 41 Relè Stirrer IN 29 42 15V ~ AC (agitation) IN 30 43 15V ~ AC (agitation) IN 31 44 NC - - 45 NC - - 46 NC - - 47 NC - - 48 NC - - 49 NC - - 50 Thermistor IN 32 51 Thermistor IN 33 52 Thermistor Shield OUT 34 53 Pt100 IN 35 54 Pt100 IN 35 55 Pt100 IN 36 56 8 V ~ AC (CPU) IN 37 57 8 V ~ AC (CPU) IN 38 58 NC - - 59 NC - - 60 12 V ~ AC (sensors) IN 18 61 12 V ~ AC (sensors) IN 19 35

FAN The fan system takes the heat produced by the peltier cell out of the unit. PRINTER COMMUNICATION The communication from the board up to the printer is realized with a RS232 communication interface. 36

FUSES The instrument has 2 fuses of 6,3 A each. To replace the fuses, please follow this procedure: 1. Disconnect the cryoscope from the main supply. 2. Open the fuse compartment. 3. Replace the fuses. 1 2 3 1. Main switch 2. Fuse compartment. 3. Supply connector. FEATURES -- Mechanical features: Dimensions: 255 x 360 x 370 mm Weight: 18,5 Kg -- Electrical features: Power supply: 230 V 50 Hz Electrical consumption: 150 W Overload fuses: 2 x 6,3 A Main supply voltage maximum fluctuations: ± 10% of the nominal voltage Transient overvoltages: II Board: CryoSmart2 Software: 1.5 -- Operating features: Maximum altitude: 2000 m Maximum relative humidity: 80% for temperatures up to 31 C decreasing linearly to 50% relative humidity at 40 C. Operating temperature: from +5 C to +40 C. Storage temperature: from 10 C to +50 C. 37