MODEL 1200LB 1200 POUND MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR

Similar documents
MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

MODEL 1200S MAGNETIC LOCK

MODEL 600S 600 POUND SINGLE MAGNETIC LOCK SPECIFICATIONS

MODEL 600LB 600 POUND SINGLE MAGNETIC LOCK WITH LED, BOND SENSOR & DOOR STATUS SENSOR SPECIFICATIONS

MODEL 1200S MAGNETIC LOCK

V2M1200/1290 Series Maglock Installation Instructions

INSTALLATION INSTRUCTIONS 1576DE DELAYED EGRESS EMLOCK

INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK

Security Door Controls

Installation Instructions

1-3/4" MOUNTING INSTRUCTIONS: 1150 SERIES SURFACE MOUNTED 1500 LB. ELECTROMAGNETIC LOCK

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

INSTALLATION DESCRIPTION

HANDLING MECHANICAL INSTALLATION

Pre-Installation Instructions

EMLock 1500 Series. MEA Listed

INSTALLATION 8310/8320

M670/M680BD MAGNALOCK SERIES Installation Instructions

* * M400 Series. Features. Models. Trims. UL Requirements. Single Electromagnetic Locks: M420, M450, M490. Installation Instructions

INSTALLATION INSTRUCTIONS MINI EXIT CHECK DELAYED EGRESS EMLOCK 1581S

With LED, Bond Sensor E-941SA-600PQ 600-lb. (272kg) E-941SA-1K2PQ 1200-lb. (545kg) Weatherproof E-941SA lb.

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

DynaLock 705 Emmett Street Bristol, CT Phone:(860) Fax:(860)

Installation Instructions for ROFU Key Hole Mount Magnetic Locks

Installation Instructions for Slide Mount Magnetic Locks

INSTALLATION EML375. Pre-Installation Instructions. Electromagnetic Locks

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE ELECTROMAGNETIC LOCK.

Package Contents. Mounting Hardware

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

AL600ULX Series. Power Supply/Charger Installation Guide

MagForce+ The Positive Force in Electromagnetic Locks

MODEL 3002xTJ32 ELECTROMAGNETIC LOCK INSTALLATION INSTRUCTIONS

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

E-941SA-300RQ. Manual. 300-lb Single-Door Electromagnetic Lock with Reversible Magnet

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty.

Instructions For PG-1200RC Magnetic Locking Devices

2904 Power Supply Installation Instructions I-EA00041

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

STANDARD / DOUBLE STANDARD MAGNETIC LOCK

Installing the gate post bracket with the cardboard arm template

Installing the gate post bracket with the cardboard arm template

ME217PIB / ME503PIB SMART INTERLOCK TECHNOLOGY ACME ADAPTER INTERLOCK BRACKET INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTIONS SHEAR LOCKING MAGNET 1561TJ MAX. HOLDING FORCE 2000 lbs.

LCN AUTOMATIC OPERATORS

CARE-C Light Curtain Installation Instructions.

Alarm Controls Product Guide

2965 Magnetic Shear Lock Installation Instructions

SECURITY DOOR CONTROLS

MEP801PIK / MEP801PIKL / MEP801PIH / MEP801PIHL SMART INTERLOCK TECHNOLOGY HOSE END VALVE HOLSTER INSTALLATION AND OPERATING INSTRUCTIONS

MOUNTING INSTRUCTIONS FOR TJ1000 SERIES INSWINGING DOORS ******READ THOROUGHLY BEFORE INSTALLING******

COOKSON OWNER'S MANUAL

INSTALLATION MANUAL ACL 5500 COMBUSTION SAFETY CONTROLLER

50 1/50 2 Directional Contactor Installation

* * M400 Series Double Locks. Double Electromagnetic Locks: M422, M452, M492. Installation Instructions. Mounting Bracket (2)

MODEL SCA Installation and Operation Manual Important:

SECURITY DOOR CONTROLS 801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

GateCrafters Automatic Gate Lock Instruction Manual GCLOCK

1.0 Features and Description

General Information. Notations and Conventions. Compatibility Check. Kit Description. Call-Outs. Part Lists Great Plains Manufacturing, Inc.

Top-of-Pole Mount for 6 Modules (TPM6) For Module Type D

Models: DC Electric Vibrators. Operating Instructions CEG CEG CEG CEG CEG CEG

Installation, Operation, and Maintenance Manual. Automatic Fire Damper

Sunwize Water Pumping Kit Quick Start

Sunwize Power Ready Express Quick Start

ME868PIB SMART INTERLOCK TECHNOLOGY TURBO FLO LE PROXIMITY INTERLOCK BRACKET INSTALLATION AND OPERATING INSTRUCTIONS

GE Sensing & Inspection Technologies

USERS GUIDE LO-21U LOCKOUT RELAY

INSTALLATION MANUAL FSS1 HIGH SECURITY DOOR MONITORING SENSOR

280+ SHEARLOCK INSTALLATION AND WIRING MODELS: 280+ and 280+TRD TRD

INSTALLATION AND OPERATING INSTRUCTIONS For Model M38 and M68 Magnalocks (Versions L, S and LS with D and T Options)

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

LOCKNETICS MagForce+ Series. Locknetics MagForce Traffic Control Magnet MEA

Accessories 286 SDC SECURITY DOOR CONTROLS

8. Do not install this product on the exterior of buildings. 9. Do not use as a doorstop. This will void warranty. Installation Instructions

Procedure Replacing a Cover

Top-of-Pole Mount for 6 Modules (TPM6) For Module Types A, B, & C

LCN 9740 SERIES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

30GX AIR-COOLED LIQUID CHILLER

EMLock Magnetic Locks

The Complete System Solution! Highest Grade Electronic Components RoHS Compliant.

INSTALLATION INSTRUCTIONS

RETRO SOLUTIONS PRODUCT CATALOG

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

Vehicle Rear Observation System With Integrated Parking Sensors

SIGNETMARINE. Livewell Bait Pump Alarm. No Dead Bait.

E-S Allegiant Series Single Swing and Dual Swing Gate Opener

cel SECURITY DOOR CONTROLS Value Engineered Access Hardware sdcsecurity.com Power Supplies Exit Switches

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION

12V Central Lock Universal Remote For Keyless Entry p/n

9540 SERIES FEATURES SINGLE DOOR, SURFACE MOUNT (PUSH) OFFSET PIVOT/BUTT HINGE

Excel Series Value Engineered Access Hardware

INSTALLATION INSTRUCTIONS

Vertical Housing EMLock Discount Code GK LIST. Retrofit Kit for Discontinued Locknetics 390+ PLUS

EMLock Magnetic Locks

Transcription:

MODEL 1200LB 1200 POUND IC LOCK WITH LED, BOND SENSOR & STATUS SENSOR U.L. LISTED, LISTING NUMBER R16756 1200 POUND MINIMUM HOLDING FORCE SIZE: 10-1/2 L x 2-7/8 H x 1-1/2 W SIZE: 7-3/8 L x 2-3/8 W x 9/16 D 12 OR 24 VOLTS DC, JUMPER SELECTABLE 400 MA. @ 12 VDC, 200 MA. @ 24 VDC BI-COLOR LED, S.P.D.T. 3A. RELAY CONTACTS 400 MA. @ 12 VDC, 200 MA. @ 24 VDC SIGNALS A POWERED & SECURELY SEALED CLEAR ANODIZED U.S. 28 FINISH STANDARD DURONIC US 40 FINISH AVAILABLE ALARM CONTROLS CORPORATION 19 BRANDYWINE DRIVE DEER PARK, NY 11729 1 631 586-4220 1 800 645-5538 WWW.ALARMCONTROLS.COM EMAIL INFO@ALARMCONTROLS.COM

IC LOCK INSTALLATION INSTRUCTIONS PLEASE READ BEFORE INSTALLATION ALARM CONTROLS CORPORATION OFFERS A COMPLETE LINE OF IC LOCKS AND ACCESSORY ITEMS TO ASSIST THE INSTALLER IN MANAGING EVERY APPLICATION. THE IC LOCK IS DESIGNED TO MOUNT TO THE FRAME ON THE STOP SIDE OF THE IN A TYPICAL OUTSWINGING INSTALLATION,(SEE PAGE 2 FOR INSWINGING INSTALLATION). SUFFICIENT HEADER SPACE MUST BE AVAILABLE TO MOUNT THE IC LOCK TO INSURE A SAFE AND SECURE INSTALLATION. 1. NOTE TYPE OF FRAME HEADER AND INSTALL FILLER OR ANGLE BRACKET AS REQUIRED TO PROVIDE A FLAT MOUNTING SURFACE ON THE HEADER THE ENTIRE LENGTH OF THE IC LOCK. OUTSWINGING INSTALLATION HEADER FILLER HEADER HEADER HEADER ANGLE BRACKET OUT SWINGING SOLID OUT SWINGING OUT SWINGING 2. FOLD TEM ON DOTTED LINE TO FORM A 90 DEGREE ANGLE. TAPE TEM AGAINST HEADER WITH IN A CLOSED POSITION 1 FROM FRAME OPPOSITE HINGE SIDE OF JAMB. FOR A PAIR OF DOUBLE S PLACE TEM AT THE CENTER OF THE OPENING. TRANSFER HOLE LOCATIONS TO AND FRAME HEADER, (SEE TEM INSTRUCTIONS). 3. FOLLOW TEM INSTRUCTIONS FOR HOLE SIZES. USE THE ILLUSTRATIONS BELOW TO DETERMINE THE PROPER HOLE PREPARATION FOR THE ACCCORDING TO THE TYPE IN THE INSTALLATION. THE INCLUDED HARDWARE PACKAGE CONTAINS ALL NECESSARY ITEMS TO COMPLETE THE INSTALLATION. TO REMOVE THE HEADER INSERT HEX KEY INTO HOLES LOCATED AT THE BOTTOM OF LOCK ON THE RIGHT AND LEFT SIDE AND UN-SCREW THE CAP SCREWS HOLLOW STEP 2 FOLLOW WITH 1/2 DIA. HOLE THRU STEP 1 DRILL 1/4 DIA. HOLE THRU SIDE OF STEP 2 DRILL 1/2 DIA. HOLE THRU SEX BOLT SIDE OF STEP 1 DRILL 21/32 DIA. HOLE THRU SIDE OF ONE THICKNESS ONLY ONE THICKNESS ONLY MUST ROCK ON MUST ROCK ON ALARM CONTROLS CORPORATION 19 BRANDYWINE DRIVE P.O. BOX 280 DEER PARK, NY 11729 800 645-5538 WWW.ALARMCONTROLS.COM

INSWINGING INSTALLATION WITH L- Z BRACKET FRAME STEP 1 FASTEN THE L BRACKET ON THE FRAME IN A SUITABLE LOCATION. MOUNT THE IC LOCK TO THE L BRACKET. MAKE SURE THAT THE IC LOCK DOES NOT OBSTRUCT THE CLOSING OF THE. L BRACKET CONNECT THE CORRECT VOLTAGE TO THE. ADJUSTABLE Z BRACKET STEP 2 ASSEMBLE THE Z BRACKET WITH THE SOCKET HEAD CAP SCREWS PROVIDED. DO NOT TIGHTEN THE CAP SCREWS AT THIS TIME. THE Z BRACKET MUST BE ADJUSTABLE. BOLT RUBBER WASHER METAL WASHERS STEP 3 MOUNT THE TO THE ADJUSTABLE SECTION OF THE Z BRACKET WITH THE BOLT. DO NOT REMOVE THE RUBBER WASHER ATTACHED TO THE BOLT. USE ONE RUBBER WASHER BETWEEN TWO METAL WASHERS ON THE BOLT. THE WASHER ASSEMBLY MUST BE BETWEEN THE AND THE ADJUSTABLE SECTION OF THE Z BRACKET. APPLY THE SCREW LOCKING AGENT TO THE BOLT. DO NOT OVER TIGHTEN. MUST ROCK TO ALIGN WITH THE. ADJUSTABLE SECTION OF Z BRACKET WITH ATTACHED Z BRACKET ASSEMBLY STEP 4 CLOSE THE AND ALIGN THE TO THE AND APPLY POWER TO THE. LET THE BOND TO THE. BE SURE THE Z BRACKET ASSEMBLY IS FIRMLY AGAINST THE CLOSED. TIGHTEN THE CAP SCREWS HOLDING THE Z BRACKET ASSEMBLY. FASTEN THE Z BRACKET ASSEMBLY TO THE WITH THE SCREWS SUPPLIED. COMPLETED INSWINGING INSTALLATION STEP 5 CHECK THE COMPLETED ALIGNMENT AND INSTALLATION OF THE AND BY OPENING AND CLOSING THE BY ENERGIZING AND DE-ENERGIZING THE IC LOCK SEVERAL TIMES. THIS WILL INSURE THAT THE CORRECT OPERATION AND ALIGNMENT OF THE IC LOCK HAS BEEN PROPERLY INSTALLED.

IC LOCK L / Z BRACKETS FOR INSWINGING S AM2370 FOR 300 POUND IC LOCK AM3370 FOR ALL 600 POUND MODELS OF SINGLE IC LOCKS AM6370 FOR ALL 1200 POUND MODELS OF SINGLE IC LOCKS AM3375 FOR ALL 600 POUND MODELS OF DOUBLE IC LOCKS AM6375 FOR ALL 1200 POUND MODELS OF DOUBLE IC LOCKS IC LOCK CARE AND MAINTENANCE IC LOCKS HAVE NO INTERNAL MOVING PARTS AND REQUIRE A MINIMUM AMOUNT OF MAINTENANCE. IT IS RECOMMENDED THAT THE FACE OF THE AND BE WIPED CLEAN AND A L IGHT COATING OF A SUITABLE SILCONE LUBRICANT BE APPLIED TO EACH SURFACE TO PREVENT RUST ALTHOUGH THE MATING SURFACES HAVE BEEN D. THIS ONLY NEEDS TO BE DONE WHEN DIRT BUILD-UP IS NOTICED. THE BOLT AND THE HEX HEAD SCREWS HOLDING THE TO HEADER SHOULD BE CHECKED EVERY THREE MONTHS TO INSURE A SAFE AND SECURE INSTALLATION. IC LOCK ELECTRICAL SPECIFICATIONS 300 POUND MODEL SINGLE IC LOCK, 250 MA. @ 12 VDC, 130 MA. @ 24 VDC ALL 600 POUND MODELS OF SINGLE IC LOCK, 400 MA. @ 12 VDC, 200 MA. @ 24 VDC ALL 1200 POUND MODELS OF SINGLE IC LOCK, 400 MA. @ 12 VDC, 200 MA. @ 24 VDC ALL 600 POUND MODELS OF DOUBLE IC LOCKS, 400 MA. @ 12 VDC, 200 MA. @ 24 VDC, EACH LOCK ALL 1200 POUND MODELS OF DOUBLE IC LOCKS, 400 MA. @ 12 VDC, 200 MA. @ 24 VDC, EACH LOCK ALL IC LOCKS ARE SET AT THE FACTORY FOR 24 VDC TYPICAL IC LOCK WIRING POSITIVE FILTERED DC POWER SUPPLY N/C REX BUTTON DIGITAL KEYPAD PIR + - IC LOCK NEGATIVE

WIRE GAUGE CHART DISTANCE FROM POWER SUPPLY TO IC LOCK 12 VDC 24 VDC 50 100 150 200 300 400 500 750 1000 200 MA. D C 300 MA. C U R R E N T 400 MA. 600 MA. 800 MA. 8 GA. 1 AMP. 8 GA. TROUBLE SHOOTING GUIDE PROBLEM CAUSE SOLUTION LOCK BUZZES INSUFFICIENT HOLDING FORCE DOES NOT LOCK AC VOLTAGE CONNECTED TO LOCK AC RIPPLE IN POWER SUPPLY INCORRECT INPUT VOLTAGE LOW INPUT VOLTAGE MISALIGNMENT OF SCREWED TIGHT TO WRONG HARDWARE ASSEMBLY NO POWER TO SUPPLY DC VOLTAGE TO LOCK REPLACE POWER SUPPLY CHECK VOLTAGE JUMPER POSITION FOR CORRECT VOLTAGE SETTING LOCK SET AT FACTORY FOR 24 VDC CHECK POWER SUPPLY VOLTAGE WIRE GAUGE INCORRECT FOR WIRE RUN MUST COVER ALL IC POLES OF LOCK MUST ROCK ON TO ALIGN WITH LOCK A METAL WASHER,RUBBER WASHER AND METAL WASHER MUST BE BETWEEN AND CHECK POWER AT LOCK CHECK POWER SUPPLY CHECK ALL CONNECTIONS STATUS SENSOR NOT WORKING (APPLICABLE MODELS) IN NOT ALIGNED WITH LOCK ALIGN IN WITH STATUS SENSOR DOT ON LOCK

IC LOCK WIRING INSTRUCTIONS MODELS WITH BOND SENSOR & STATUS SENSOR 600LB, 600DLB, 1200LB, 1200D IMPORTANT ON ALL MODELS REMOVE TERMINAL COVER SCREW TO ACCESS HEADER MOUNTING SCREW BOND SENSOR V+ V- N/O COM N/C WIRING INSTRUCTIONS CONNECT POSITIVE LOCK POWER TO V+ TERMINAL CONNECT NEGATIVE LOCK POWER TO V+ TERMINAL P1 P2 OPERATION OF BOND SENSOR AND LED THE BOND SENSOR DETECTS WHEN THE IC LOCK IS POWERED AND IS CLOSED. OPEN, LOCK NOT POWERED: RELAY OFF LED OFF CLOSED, LOCK POWERED: RELAY ON LED GREEN CLOSED, LOCK NOT POWERED: RELAY OFF LED OFF OPEN, LOCK POWERED: RELAY OFF LED RED VOLTAGE SELECTION FOR 12 V FOR 24 V P1 P2 VOLTAGE IS FACTORY SET FOR 24 VDC ANTI-ROTATION PIN STATUS SENSOR BOLT HOLE ORIENTATION OF THE AND A B ANTI-ROTATION PIN PERMANENT INSTALL THE AND AS SHOWN. IF NOT POSITIONED AS SHOWN THE OPERATION OF THE SENSOR OUTPUT WILL BE AFFECTED. STATUS SENSOR THE STATUS SENSOR,(REED SWITCH), IS NORMALLY-OPEN. WHEN THE IS AGAINST THE THE CONTACTS ARE CLOSED. THE TWO WHITE/GREEN LEADS,(A,B),ARE FOR THE STATUS SENSOR. WHEN MOUNTING ON RUBBER WASHER MUST BE PLACED BETWEEN METAL WASHERS. DO NOT EXCESSIVLY TIGHTEN SEX BOLT. MUST FLOAT ON.THREAD LOCKING AGENT SHOULD BE USED. ALARM CONTROLS CORPORATION DEER PARK, NEW YORK 11729 PH: 1 800 645-5538 FAX: 1 631 586-6500 EMAIL: INFO@ALARMCONTROLS.COM WEBSITE: WWW.ALARMCONTROLS.COM