Installation and Setup Instructions

Similar documents
Installation and Setup Instructions

L400S, L400S Marine Installation Manual Version No 1.0.5

Master Pumps Installation Manual Version No 1.0.2

AdBlue Laser V50 Installation Manual Version No: Model: AdBlue Laser V50 Date: 23/02/2018

AdBlue Master V50 Installation Manual v Model: AdBlue Master Dispensers Date: 15 th November 2018

C4000 Master Manual. Version 1.0.0

Communicator Installation Sheet. Version 1.0.1

LPG DISPENSER SERVICE MANUAL

Pumps & Dispensers MASTER LASER PUMP FEATURES»»»»»»»» PUMP FEATURES»»»»»»»»

CNG DISPENSER SERVICE MANUAL

ComFutra Installation Sheet. Version 1.0.0

Installation Manual Version No 1.0.4

CNG Dispenser Owner's Manual. Version 1.0.2

CNG Unloading Post Installation and Service Manual

COMPAC PRODUCT RANGE

CNG Dispenser Installation Manual Version No: 1.0.1

CNG Dispenser Service Manual Version 1.1.2

Certificate of Conformity

TRIPS AND FAULT FINDING

Card King Installation Sheet

MODEL 422 Submersible Pump Controller

GLM SERIES CONTROL Users Manual Rev:

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

ComTank Unit Installation Sheet. Version 1.0.0

SentryGOLD Compact. for Bennett Electronic Dispenser INSTALLATION MANUAL. Fuel Management System

3 Phase Smart Controller

ARM V FDBK ENSURE MOTOR IS NOT ROTATING DURING POWER UP STILL FAULTS? YES ENSURE ARMATURE WIRING IS ISOLATED FROM ANY OTHER POWER LEADS STILL FAULTS?

Installation and Maintenancee Manual

BIM-17-2 Bus Interface Module for compass and outside temperature

OnCommand Troubleshooting Guide Hayward Industries

Card King Installation and Service Manual

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

IRRIGATION CONTROLLER

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires it.

Maximiser Progressive Controller

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

GILTRAP GENERATION II RF CONTROL SYSTEM

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

RR4T USA - RS4T USA

Certificate of Approval NMI 12/1/8

OPT SCR200 Installation Manual Version No: Model: OPT Mark 2 SCR200 Date: 20/03/2018

Instructions for Use

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

Stratomaster Smart Single

ST315B. User Handbook STAFFOR. ST315B Temperature Programmer. See separate handbook for Installation Instructions Issue: 2.00

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

DIESEL Engine Fire Pump Controllers Features

HWP Protection Board

CHUBBSAFES EVOLVE INSTRUCTION MANUAL

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Gas Actuated Valve Supplement

Instructions for the BCEA Rotary heat exchanger

REVISION HISTORY REVISION HISTORY

Instruction Manual MINI IRRIGATION CONTROLLER.

1999 Mercury Cougar ACCESSORIES & EQUIPMENT' 'Passive Anti-Theft Systems - Cougar 1999 ACCESSORIES & EQUIPMENT

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Gate & Door Controller with LCD and Intelligent Technology

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

12V DC MOTORISED OPENER FOR SWING GATES Section Table of Contents Page

OPERATOR S MANUAL X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

TECHNICAL SERVICE MANUAL FOR MASTERTIG ACDC MACHINES

Issue 2.0 December EPAS Midi User Manual EPAS35

Fault Codes. J control

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

THERMOMETER PROJECT KIT

S D ST215 TAFFOR. ST215 Temperature Programmer User Handbook.

EPC DC MOTOR SPEED CONTROL

CeraControl. Temperature Programmer User Handbook.

TALON 22 WHEEL & TALON X-TREME 38 WHEEL TPMS, UP to 188 PSI PRESSURE AND TEMPERATURE WITH CAP OR FEEDTHRU SENSORS

Ezyfit AC Controller INSTRUCTION BOOK 2 & 4 STATION UNITS

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

CABINET REEL OPERATING INSTRUCTIONS

WARNING: ALWAYS UNPLUG THE TREADMILL FROM THE ELECTRICAL OUTLET BEFORE SERVICING THE UNIT.

PFC W HF/PFC Battery Charger

SM361 RIG SWITCH CONSTRUCTION MANUAL

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

KEMKRAFT ENGINEERING, INC. MODEL KEI-234 STEERING WHEEL TORQUE/INCLINOMETER TESTER

STR3. Step Motor Drive. User Manual

TEL: G&C Electronics CC E. T.

Automatic Sliding Door Retrofit Drive Assembly. Installation Manual DoorControlsUSA.com

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, G)

Pressure chlorine changeover unit C 7520

EGT-100 Operations and Installation Manual

3000W HF/PFC Battery Charger

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

WARNING: ALWAYS UNPLUG THE TREADMILL FROM THE ELECTRICAL OUTLET BEFORE SERVICING THE UNIT.

Product Data Sheet. Damper Interface. Features

Marine Exhaust Temperature Alarm. COMPONENTS

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

Triton ATM Error Codes

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

ODY-19-6 DUAL, TRIPLE, or QUAD AIR PRESSURE GAUGE

KD LV Motor Protection Relay

Standards Are Fit For Use Standard must be free of leaks, dents and seals must be intact

Wiring Main Power connector constant 12V power

Transcription:

Installation and Setup Instructions Model: Master Version: MMR80-40S Date of issue: 22 May 2009 Compac Industries Ltd P O Box 12-417 Penrose Auckland New Zealand Ph 64 9 5792 094 Fax 64 9 5790 635 www.compac.co.nz 22MAY09.doc Page 1 of 12

1. Footprint... 3 2. Static Electricity Precautions... 4 3. Pre-installation Check... 4 4. Comms Dip-switch settings... 4 4.1 Standard Pump Comms Setting... 4 4.2 Gilbarco Pump comms Setting... 4 5. Triac Dip-switches... 4 6. Electrical Connections... 5 6.1 Submersible Pump connections... 5 7. Dispensing Hoses and Nozzles... 6 8. Setting up the C4000... 6 8.1 Configuration Codes... 6 8.2 Submersible Delay (Sd)... 6 8.3 Parameter Switch Settings... 7 8.4 K-Factor Switch Settings... 8 9. Calibration (K-Factor)... 9 9.1 Setting the K-Factor... 9 9.2 Sealing the K-Factor switch... 9 9.3 Standalone Operation... 10 10. Spare Fuses... 10 11. Error Messages... 11 12. MMR40/80S Spare Parts... 12 22MAY09.doc Page 2 of 12

1. Footprint Note: This drawing does not apply to Aviation dispensers (stainless steel pipework) 22MAY09.doc Page 3 of 12

2. Static Electricity Precautions Electronic components used are sensitive to static. Please take anti-static precautions. An anti-static wrist strap should be worn and connected correctly when working on any electronic equipment. If an anti-static wrist strap is unavailable, or in an emergency, hold onto an earthed part of the pump/dispenser frame whilst working on the equipment. This is not a recommended alternative to wearing an anti-static wrist strap. Note: Compac Industries Limited reserves the right to refuse to accept any circuit boards returned, if proper anti-static precautions have not been taken. 3. Pre-installation Check Once the pump is received on site, check that no damage has occurred while in transit in particular, damage to electronics due to vibration or jarring. All terminals and plugs should be checked, including IC chips, to ensure they are securely in place. 4. Comms Dip-switch settings 4.1 Standard Pump Comms Setting (Dipswitch SW3) 1-ON 2-OFF 3-ON 4-OFF These are factory set to the standard setting unless ordered otherwise.eg Gilbarco. 4.2 Gilbarco Pump comms Setting (Special software and interface board required) 1-OFF 2-ON 3-OFF 4-ON 5. Triac Dip-switches Important note: Great care should be taken not to accidentally change the setting of these switches while working in the Flame-proof box. Operating the unit with these incorrectly set can result in damage to the C4000 Power Supply or incorrect operation of the triacs. These switches are set in the factory and should not be changed. If they are accidentally changed these are the correct settings for Master / Premier Dispenser applications.note: They are 3 position switches Dispenser (low current output) SW1 2 SW2 2 SW4 2 22MAY09.doc Page 4 of 12

6. Electrical Connections Prior to pump installation ensure that there is at least a two-metre tail on both the incoming underground 230 volt cable and Comms cable. These cables are terminated at the C4000 Power Supply, which is housed in the Flameproof Enclosure located in the bottom of the pump, behind the Door The incoming cables are terminated as shown in the following picture. Refer to AS/NZS 2381.1 for appropriate cabling. 6.1 Submersible Pump connections Dual, Duo, Quad and 4 Hose Multi Dispensers Connect the feeds to the Submersible Pump Relays / Contactors to the C4000 Power Supply as follows: Side A to terminal marked T1 Side B to terminal marked T4 If both sides are required to switch the same Submersible T1 and T4 should be linked together Note: The terminals marked LOAD 1 & 2 are not used in Dispenser applications 22MAY09.doc Page 5 of 12

7. Dispensing Hoses and Nozzles The unit may or may not be supplied with dispensing hose and nozzle assemblies. If customer supplied hose assemblies, pylons, reels, safe breaks and nozzles are used they must comply with the requirements outlined in AS/NZS 2229 8. Setting up the C4000 Once the pump is connected on site, the final setup check and calibration to complete the installation must be carried out, using the Parameter Switch and Calibration (K-Factor) Switch. These switches are found on the C4000 Microprocessor Board which is housed in a metal enclosure located on the left front of the unit below the display panel 8.1 Configuration Codes The configuration code has been set at Compac and should not be changed In the event of it being lost and having to be re-entered the configuration is written on the yellow label on the C4000 processor board cover 8.2 Submersible Delay (Sd) This is the time delay from when the Submersible pump starts to when the solenoids in the dispenser open to allow time for the leak detector to reset. This is factory set by Compac at 005 (five seconds). If problems are experienced with the leak detector tripping, firstly check that 'Sd' is still set and then, if necessary, make it longer as follows. 1. Press and release the K factor switch repeatedly until 'Sd' appears on the Dollar display 'dxxx' will appear in the litres display. 2. Continue to press the K factor switch until the number to be changed flashes. Hold the switch down and this number will then increment. 3. Release the switch when the required number is displayed. The value of the displayed number will then be stored in the C4000 memory as the Submersible delay. 22MAY09.doc Page 6 of 12

8.3 Parameter Switch Settings 8.3.1 Setting the Pump Number This must be set at the pump, for each hose, so that communications with a controller can take place. The location of this switch is shown in the diagram below. Depress the Parameter Switch nine (9) or more times until the message 'PnA XX' appears in the litres display window. When the switch is pressed again 'Pnb XX ' will appear on the display. These two options will toggle each time the switch is pressed. To alter either of the pump numbers, press and hold the Parameter Switch when the pump number to be altered appears on the display. This number will then increment. The switch should be released when the desired pump number is displayed. The value of the displayed number will then be stored in the C4000 memory as the pump number for that hose. NOTE: For a single hose only Pn will appear 8.3.2 Setting the Price Using the Parameter Switch, follow the chart to set the price for the hose(s) in question. Step ACTION RESULT 1 Ensure that the nozzle is hung up Dispenser in idle state 2 Press and Hold the Parameter switch until the Price per litre is displayed. The price for side A is shown as PX.XXX on the litres display and PrA is displayed on the money display. 3 Press and hold the Parameter switch. A digit, of the displayed Price per litre, will begin to increment. 4 When the digit is correct, release the Parameter switch. 5 Repeat steps 3 and 4 for each digit of the Price per litre. 6 Press and release the Parameter switch 8 or more times in quick succession 7 Repeat steps 3 to 5 above. NOTE: the C4000 will reset itself if the Parameter switch is left for more than 60 seconds. Continue for Dual hose units The price for side B is shown as PX.XXX on the litres display and Prb is displayed on the money display. 22MAY09.doc Page 7 of 12

8.4 K-Factor Switch Settings K-Factor, and other various configuration settings, are set via this switch. The position of the K-Factor switch is shown in the diagram below: Parameter Switch K factor Switch K Factor Switch Parameter Switch J1: Comms Test J7: Displays J13: Not used J2: To Power Supply J8: Temperature (for J14: Not used Temperature compensation only) J3 : Input from KG Meter J 9 Power for KG Meters J15: Not used Side A J4: Input from KG Meter J10: Totes J16: Not used Side B J5 : Not Used J11: Buzzer J17 Backlighting J6 Not used J12 Nozzle Switches 22MAY09.doc Page 8 of 12

9. Calibration (K-Factor) 9.1 Setting the K-Factor K-Factor is a proportional calibration factor of litres dispensed per revolution of the meter. To calibrate the dispenser/pump, dispense fuel into a certified measuring container, and compare the display value with the amount dispensed. Example: Display shows 10.00 True volume 20.00 To calculate the correct 'K' Factor from the information above; firstly record the existing 'K' Factor. New ' K' Factor = Existing ' = Existing ' = Existing ' K' Factor K' Factor K' Factor Dispensed Amount Displayed Amount 20.00 10.00 2 Change the existing 'K' Factor to this new value. 9.2 Sealing the K-Factor switch After calibration the K-factor switch should be sealed as shown 22MAY09.doc Page 9 of 12

9.3 Standalone Operation In standalone operation, the dispenser will continue working when not connected to a controller. 'Stand-alone' mode being when no authorisation of fills is required and so fills are simply initiated by removing the refuelling assembly from its holder. If standalone operation is inhibited, the dispenser will not work in 'stand-alone' mode, regardless of whether the dispenser is ON LINE to a controller or not. The dispenser ceases to work in 'stand-alone' mode if connected to a controller, regardless of the position of standalone setting. Generally on retail forecourts the dispenser should be set-up for standalone operation. Hence, if the forecourt controller breaks down the dispensers can be set to work in 'stand-alone' mode simply by turning them off then on again. For unattended refuelling sites, the dispensers should not be able to work in 'stand-alone' mode in the event of a controller failure. Therefore the dispenser should be set-up to inhibit standalone operation. This is set in the 'b' code on the K factor switch. The 'b' code to run Standalone without Dispenser Controller is 0000. The 'b' code to inhibit Standalone is 1000. 10. Spare Fuses In the event of a fuse blowing on the C4000 Power supply a bag of 3 is included in each flameproof box. Any fuses used from this bag should be replaced Note: There are three different ratings used. If replacing a fuse, ensure that the correct value is used. 22MAY09.doc Page 10 of 12

11. Error Messages Error Code Fault Action Err 3 No price or pump number set. Set the pump number or: Set a price at the pump or at the controller. Err 7 Excess flow. Max Flowrate exceeded Err 8 Err 9 Excess reverse rotation of encoder. Faulty or disconnected meter encoder. Check product is not flowing back into the tank once the delivery has finished. 1. Check that encoder is plugged in. 2. Replace encoder PCB on meter Err 10 Configuration Lost Reconfigure C4000 refer to C4000 manual Err 12 C4000 memory failure. Change memory IC. F-AD-DS1225 (not applicable to Futra) Ped Abd Display error 1. Check display cable for loose wires/crimps 2. Replace display PCB 22MAY09.doc Page 11 of 12

12. MMR80-40 Spare Parts Commercial Display (includes backlighting) F-CP-DISPLAY-COM Retail display (as shown - includes backlighting) F-CP-DISPLAY-GD1 Tote F-BA-TOTE-A-K C4000 Microprocessor Board F-CP-C4PROCES-A Nozzle Holder F-NOZL-HLDR-ME-50 COM50 Meter (complete) F-METER-COM50 COM50 Meter (electronics) F-METER-COM-E Solenoid (complete) F-SOLND-S20-XLGM Solenoid (Seal Kit only) F-SOLND-S20-SK Filter Element F-FILTER-SE10 C4000 Power Supply (does not include box) F-CP-C4PWR-ASSEM Also (not shown) Track 2 cardreader F-BA-CARD-T2C4M PINPad (not shown - Fascia c/w keypad only) F-CU-PINPAD-FAS Preset (not shown - Fascia c/w keypad only) F-CU-PRESET-FAS 22MAY09.doc Page 12 of 12