Inazuma Installation and Operating Instructions INAZUMA HD PRO UV-C. High-Performence Duo UVC Lamp

Similar documents
Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

MANUAL. Single charger

HST-BL-2830MS & HST-BL-2830MS-USA

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS

WARNING Risk of property damage, injury, or death.

OWNER'S MANUAL. Royal Sovereign International Inc. RET Desk Series

Installation manual Complete set active Sound incl. Soundbooster Skoda Octavia 5E

Contents Copyright...2 General advice...2 Safety instructions...3 References of legal regulations for operation...3 Space of delivery for 37998, 37998

Installation Instructions Complete set Active Sound incl. Soundbooster Audi A3 8P

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Operating Instruction for Downlights

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

Original Operating Manual

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

Installation manual wall-mounted distributor

Operating instructions ErgoPack 600 E

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

Installation Instructions Complete set active Sound incl. Soundbooster Mercedes A-Klasse W176

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

pond and garden 3 x 1 watt / 5 x 1 watt

Operating Instructions MP 6. perma-tec GmbH & Co. KG perma MP 6 perma-tec GmbH & Co. KG perma MP 6

Pressure relief valve

Belt Conveyor Pull Rope Switch Types HEN, HEK and SEM OPERATING INSTRUCTIONS

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

ADN-W BA. Li-Ion Battery Pack. Instruction manual

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

21", 33", 45", & 61" Installation & Operation Manual

PURE SINE WAVE DC TO AC POWER INVERTER

Compact System NRGS 11-2 NRGS Original Installation Instructions English

28W WORK LAMP Model: CTL28 Part No:

KSZ 10B Current Probe Calibrator. Instruction Manual

Armon Edero. User manual

Battery charger , A, B

Safety, Installation and Service Manual Models 1952, 1953 & 1972

Mod: KLD6-12/35XLAS-N

OWNER'S MANUAL ARCLINE 6

Technical Documentation

HST -LS Interlocking device (Translation of Original Manual)

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

DeltaSol AX * *

OPERATIONS MANUAL CR Thermoreactor

Instruction manual. Liftkar HD Uni Liftkar HD Fold Liftkar HD Dolly Liftkar HD Fold Dolly. Issued: 10/2010 subject to updates.

NANOpure Infinity UV Module Upgrade

ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

OWNER'S MANUAL MYCRO 8

KeContact P20. User manual

UV Transilluminator Dual Wavelength (Large)

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

Operation Manual. Battery Charger ARTIKEL CHF CHF-4803

Operating Instruction for Pneumatic shears Type : NP 15/20 NP 25/30 NP 35/40

HQUA. UV Water Sterilizer Instruction Manual. Contents

Operating Instructions type Always on the safe side.

C-max U2. Stair Climbing System. User s Manual

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds

UZK12.071, UZO GENERAL DESCRIPTION 2. DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

MANUAL RGB DIGITAL STRIP. LED-Strip #57016 ENGLISH

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

INSTALLATION INSTRUCTIONS

KSZ 100B Current Probe Calibrator. Instruction Manual

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

first issue : last change : MSD Platinum 15 R number of pages : 12 LE 2166

UZK12.071, UZO DATA 1. GENERAL DESCRIPTION 4. MARKINGS 3. ORDER NUMBERS PASSIVE BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

V4 Cordless Lamp System User Guide

Ultrasonic Leak Detector and Seal Control Device SONAPHONE R

OWNER'S MANUAL POWER BOOSTER. Rechargeable 12 Volt DC power supply. Item # Enclose copy of original sales receipt

Relay Retrofit Program Cutting Tool Safety Guide

Operating Instructions

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

Dreamer Series. LED bulb A60. Product benefits. Product features. Product datasheet

Verti Blast. User Manual. Order code: EQLED355

Installation & Service Manual

8.50 Kampmann Equestrian Solarium Perfect Enhances the Vital Functions and the Immune System Table of Contents.

HARDWARE KIT INSTALLATION GLOVES

OWNER'S MANUAL AIR MOTION

Further information: Berriman Associates Model 850P.2 Owners Manual

Installation instructions

USE AND INSTALLATION HANDBOOK

OPERATING INSTRUCTIONS. Operating Instructions

UZK24.121, UZO GENERAL DESCRIPTION 2. DATA 4. MARKINGS 3. ORDER NUMBERS

Lamp kit. Installation manual SIM 7 series R

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

Installation instructions

OPERATING INSTRUCTIONS

Important instructions

Operating instructions K- Control 4960, 4965, Always on the safe side.

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Installation manual portable distributors

UVR-Mi UV-air flow Cleaner - Recirculator

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

SOLAR CHARGE CONTROLLER

Installation Active Sound. Active Sound Gateway BLE. Cete Automotive GmbH - Elmshorner Straße Horst -

Installation manual Complete set active Sound incl. Soundbooster Audi A4 8E

Manual / Safety notes for your E-Bike Vision Power Pack, compatible with Panasonic 26V* drive system

Transcription:

Inazuma Installation and Operating Instructions INAZUMA HD PRO 50.000 UV-C High-Performence Duo UVC Lamp

Edelstahl-Trommelfilter & High-End-Teichzubehör Index page 1. General Information... 3 1.1. Introduction... 3 1.2. Warning label... 3 1.3. Important safety notes and warnings... 3 1.4. Additional safety instructions and warnings... 3 1.5. Manufacturer... 4 1.6. WEEE-registration... 4 1.7. EC declaration of conformity... 4 1.8. Alteration and modification... 4 1.9. Spare parts... 4 1.10. Description and function of the product... 4 2. Installation and maintenance... 5 2.1. Information on installation and maintenance... 5 2.2. Connection to the ballast unit... 5 2.3. Mounting inside the filter... 5 2.4. Assembly of the UVC lamp... 6 2.4.1: Insertion of the illuminant and quartz tube... 6 2.4.2. Illuminant replacement... 6 2.4.3. Quartz tube replacement... 6 3. Technical Data... 7 4. Warranty... 7

www.inazuma-online.com 1. General Information 1.1. Introduction Congratulations on your new acquisition the highperformance duo UVC lamp HD-Pro 50.00 including a ballast unit. To avoid restrictions on function and warranty it is important to read this manual carefully. To make sure your filter works as supposed to, we ask you to follow the manual, the user- guide and additional notes that are provided with this product, closely. In the event of emerging questions not addressed in this manual we ask you to get in contact with your (local) dealer. The mains power plug is not included in delivery. The connection must be carried out according to the norm EN60335-2-109 qualified personnel. PLEASE NOTE The manufacturer will not assume responsibility for any damages emerged by misuse of the product or parts of it or by non-observance of rules, guides and manuals provided in this document and additional documents (including stickers and warning signs) provided with the product 1.2. Warning Label In this manual, you find the two signs shown below. They point out important warnings or significant Informations. 1.3. Important safety notes and warnings Please store this manual at an accessible location to beable to address emerging questions about installation, function and debugging. It is recommended to keep a copy of this manual close to the UVC so that e.g. technicians are able to get quick access to all informations needed. 1.4.Additional safety instructions and warnings Ultraviolet light can cause damage on your eyes and skin. Always protect yourself and others form direct UVC-light The UVC lamps must be mounted in a way, that nobody might be exposed to the light by accident. If you notice any painful reactions, please contact a doctor. Do not expose any humans, animals or plants to the radiation. Operate the device only, when there is no-one in the water. Put the UVC-lamp only then in operation, when it is completely under water The ballast unit is protected against splash water (protection class IP65). The Inazuma immersion-uvc can only be installed used in closed filter systems. This UVC-device is equipped with safety mechanisms and must therefore be operated in Inazuma drum filter systems only. The mains plug must be plugged in into the Inazuma Control System Clever. Only then, the automatic shut-down when opening the drum filter case cover is guaranteed. Always pull the mains plug during maintenance (e.g. changing of the illuminant or cleaning of the quartz tube). The immersion-uvc must be protected from frost. Temperatures below the freezing point can damage the illuminant or the quartz tube. In case parts of the immersion-uvc (especially the quartz glass) are damaged, the lamp must not be brought to operation. The device must be cleaned and descaled regularly to ensure a proper functioning. The device can only be operated, if your house wiring owns a ground fault circuit interrupter (GFCI) / residualcurrent device (RCD) (30 ma for humid environment) and the power supply is connected to said system. It is also recommended to use an overvoltage protection class D or 3 (depending on your local guidelines). 3

Stainless Steel Drum Filters & High-End Pond Accessories 1.5. Manufacturer Inazuma Johannes Kurzweil GmbH Eisackstrasse 16 86165 Augsburg Tel.: +49 (0)821-72 919 71 Fax.: +49 (0)821-72 919 73 E-Mail: info @inazuma-online.com Internet: www.inazuma-online.com 1.6. WEEE-registration The WEEE-registration ensures that the producers are assuming liability for their electrical and electronic equipment, especially the responsibility for recycling and disposing of these according to the ElektroG. The Federal Environment Agency of Germany (Umweltbundesamt) confirms the registration of this product under the following number: WEEE-Reg.-Nr. DE 19429673 1.7. EC-Declaration of Conformity Manufacturer: Inazuma Johannes Kurzweil GmbH Eisackstraße 16 86165 Augsburg Germany Tel.: +49 (0)821-72 919 71 Fax.: +49 (0)821-72 919 73 Device Type: Immersion UVC lamp including electronic ballast unit. 1.8. Alteration and modification We point out that every alteration or modification without written approval by Inazuma or one of its authorized suppliers will cause the immediate annulment of the CE conformity assessment. Inazuma will not assume liability for damages on persons or property emerged by unauthorized alterations or modifications. Die Inazuma immersion UVC lamp can only be used in closed filter systems by Inazuma. 1.9. Spare parts Only spare parts provided by Inazuma or one of its authorized suppliers are approved for installation. In the event of usage of non-authorized parts the warranty will expire and Inazuma will not assume liability for damages. Only use special tooling. 1.10..Description and function Energy saving high-performance immersion lamp Longlife durability of up to 16.000 hours Two lamps (55 watt each) can be plugged into one ballast unit Horizontal or vertical installation possible Wavelength range 253.7 nm (nano meters) Germ-reducing effect through destruction of the cell structure of bacteria, algae and viruses The manufacturer declares hereby the conformity of the product with the safety requirements mentioned above. 4

www.inazuma-online.com 2. Installation and maintenance 2.1. Information on installation and maintenance Can only be installed and used in closed filter systems The ballast unit must be mounted in a dry spot, where it is also protected from direct sunlight Glass or artificial glass protects from UVC radiation an can be used as a transparent coverage The immersion lamp must be protected from frost, temperatures below the freezing point can damage the illuminant and quartz tube The electronic ballast unit produces heat, that dissipates through the housing Max. operating temperature 50 C The ballast unit must be protected from direct sunlight Pull the mains plug prior to any maintenance work Any maintenance work on electrical parts must be carried out by qualified personnel Do not touch the lamp on the glass part We recommend to exchange the illuminant every two years 2.3. Mounting inside the filter All Inazuma drum filters of the MK V series and Smarty have one or multiple inboard holders for an easy mounting of the HD-Pro-50.000 UVC lamps. (see fig. 1). Mounting: Insert the immersion UVC lamp inside the stainless steel holder from above. Pay special attention to not damage the quartz tube. The Union nut of the lamp should now be laying flat on the top part of the holder (see fig. 2). 2.2. Connection to the ballast unit Connect the UVC lamp or lamps as shown in the pictures below. fig. 1 Incorrect installation will damage the ballast unit When connecting only one lamp, use the single slot on the right. fig. 2 Depending on the installation location of the UVC lamp, it might be necessary to unscrew the nut of the gas pressure absorber to be able to insert it (see fig. 3) If you want to connect two lamps, use the slots on the left side of the ballast unit. fig. 3 5

Stainless Steel Drum Filters & High-End Pond Accessories 2.4. Assembly of the UVC lamp fig. 1 fig. 2 fig. 3 Unscrew the union nut and remove the O-Ring Put the O-ring on the quartz tube. Spray the open end of the tube with silicone or similar Push the quartz tube with the open end side until it meets the last seal ring fig. 4 fig. 5 fig. 6 3 cm The quartz tube should snap 3 cm deep inside the socket Slide the union nut over the closed end and the O-ring Tighten the union nut 2.4.1. Insertion of the illuminant and quartz tube 1. Loosen the union nut and remove the O-ring, that is located inside the nut (fig. 1) 2. Slide the ring on the quartz tube and spray the open end of the tube with silicone spray or a similar lubricant (fig. 2) 3. For safety reasons we recommend to wear safety gloves in the following steps 4. Push the illuminant into the socket 5. Slide the open end of the quartz tube with some pressure 3 cm deep into the socket, so that it slides over the first seal ring and meets the last. You should hear a click. Pay attention to not tilt the tube (see fig. 3 and 4) 6. Slide the union nut you unscrewed in point 1 over the closed end of the quartz tube and slide it over the O-ring up to the bolting of the socket (fig. 5) 7. Tighten the union nut 2.4.2. Illuminant replacement ATTENTION Shock hazard 1. Pull the mains plug of the device 2. Loosen the union nut and slide it over the quartz tube (fig 1) 3. For safety reasons we recommend to wear safety gloves in the following steps 4. Pull cautiously on the quartz tube 5. Pull the old illuminant out of the socket 6. Insert the new lamp 7. Pay attention that the O-ring is still sitting on quartz tube 8. Repeat steps 5 to 7 in chapter 2.4.1. 2.4.3. Quartz tube replacement 1. Pull the mains plug of the device 2. Loosen the union nut and slide it over the quartz tube (fig 1) 3. For safety reasons we recommend to wear safety gloves in the following steps 4. Pull cautiously on the old quartz tube 5. Pay attention to slide the O-ring on the new quartz tube 6. Repeat steps 5 to 7 in chapter 2.4.1. 6

www.inazuma-online.com 3. Technical Data Power supply: 230 V / 50 Hz Max. power: 130 W Lamp power: 55 120 W Max. lifetime: 16.000 hours Protection class ballast unit: IP-65 Protection class UVC lamp: IP-68 4. Warranty The warranty includes only the device (ballast unit and lamp. Wearing parts, as the illuminant and quartz tube are excluded from warranty The manufacturer accepts no liability for any consequences resulting from inappropriate, negligent or incorrect installation or misuse and any consequences that result. The supplier s liability under this limited warranty shall extend only to the replacement of a defective product. This warranty is not transferable. 7

Edelstahl-Trommelfilter & High-End-Teichzubehör Drum Filters You will be amazed Manufacturer Inazuma Johannes Kurzweil GmbH Eisackstraße 16 86165 Augsburg Germany Tel.: (+49) 821/ 72 91 97 1 Fax: (+49) 821/ 72 91 97 3 info@inazuma-online.com www. inazuma- online.com Technical modifications and errors excepted. WEEE-Reg.-Nr. DE 46229826 Registration number: DE-BY-1-00078 Manual Version 1.03