Visit us at

Similar documents
Visit us at

Short manual testo 610

Short manual testo 410-2

Short manual testo 510

Visit us at

Visit us at

Visit us at

testo 108 Bedienungsanleitung Instruction manual Mode d emploi Manual de instrucciones Manuale di istruzioni Handleiding

testo 206 ph/ Temperature Measuring Instrument Bedienungsanleitung Instruction Manual

PHASE ROTATION INDICATOR with OPEN PHASE CHECKER

Defender 3000 Series Base Instruction Manual

Chek-A-Cell TM TestEquipmentDepot.com. Instruction Manual Rev A 8/12

EASY CHARGE Waterproof portable Battery Charger

Non-Contact Phase Rotation Tester

USER MANUAL. White LED Light Meter. Model LT40. Additional User Manual Translations available at

TIF8800X. Combustible Gas Detector. an spx brand. Owner s Manual. 99 Washington Street Melrose, MA Phone Toll Free

EASY CHARGE Weather-resistant fixed mount Battery Charger

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

KD1E Range Potential Indicators

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

TIF VA500A DIGITAL HVAC ANALYZER

DT304. Digital Temperature Logger INSTRUCTION MANUAL

Digital/Analog Megohmmeter Model 1026

INSTRUCTION MANUAL. Mi490 Peroxide value. Milwaukee Lab Photometer. Test Equipment Depot Washington Street Melrose, MA 02176

CM100. Carbon Monoxide Meter. 99 Washington Street Melrose, MA Phone Toll Free

Visit us at Please read carefully before using this product.

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Industrial flue gas probes. Instruction manual

Valor 2000 Series Instruction Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

User's Manual Digital High Voltage Insulation Tester Model

HST-BL-2830MS & HST-BL-2830MS-USA

DLRO TEST LEADS Digital Microhmmeter

MANUAL. Single charger

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

EC20 Pocket Conductivity Tester Instruction Manual

SAFETY AND CERTIFICATIONS

1.Safe testing IMPORTANT:

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

Flex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No

Triple Output Power Supply

D Dräger Alcotest 3000 Breath Alcohol Measuring Device

Digital Electronic Torque Wrench. Operating Manual. Model 60648

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

HARVARD TRIP BALANCE Series 1400 and 1500 Instruction Manual

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

Battery charger , A, B

OPERATING INSTRUCTION

Salt 1 Pocket Salinity Tester Instruction Manual

MN-IST-SD SERIES-E. IST-SD SERIES DIGITAL TORQUE SCREWDRIVER OPERATION MANUAL

6 Bay Battery Charger Operation Manual

Combustible Gas Detector

AQUATEC R / AQUATEC F / AQUATEC XL. Bathlift Operating instructions

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Mini Multimeter with Non-Contact Voltage Detector (NCV)

User Guide. Panel Mount Digital Tachometer. Model Washington Street Melrose, MA Phone Toll Free

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Information I Manuals I service. AIR premium x2. Operating Instructions _a I 03/2012

POSITIVE DISPLACEMENT FLOWMETER

ECscan40 Pocket Conductivity/TDS/Salinity Tester Instruction Manual

Operating instructions Accu Jet

PIECAL 520B & 521B Thermocouple Source Operating Instructions

Operating instructions Platform/floor scales

by Blum SERVO-DRIVE Installation instructions

OPERATING INSTRUCTION

Declaration of Conformity

C3 Operating Instructions

THWD-3 and TH-3 Relative Humidity and Temperature Meters

Garden Thermometer with Solar Lighting

Solenoid Valve ST-IA-series

ELECTRICALLY INSULATED 14mm PROBE

DC REGULATED POWER SUPPLY

SL2380. Installer s guide. Owner skit. Blind control device Battery module.

LiteBox /FireBox / Operating Instructions. (Rechargeable) 99 Washington Street Melrose, MA Phone Toll Free

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

CORDLESS COMPRESSOR WITH SPOTLIGHT + JUMP START

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

OPERATING MANUAL CMP-200

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

Switching DC Power Supply

Intelligent NiMH/NiCd/Li-ion Charger TN456

The Brose e-bike system. Instructions for use

CONTENTS ABOUT THIS MANUAL...3 SAFETY...5

Pedelec Operating Instructions Pedelec handleiding Pédélec manuel

OPERATION & MAINTENANCE INSTRUCTIONS

Manual Installation & Operation

OD10 10A Outdoor Solar Charge Controller

SERVICE MANUAL STARTER 2100 Bench ph Meter STARTER 3100 Bench ph Meter STARTER 3100C Bench ph Meter

DIGITAL RCD(ELCB) TESTER

The Traveler Series: Wanderer

WR 16SE. de fr it nl es pt sv da no fi el pl hu cs tr ro sl sk bg sr hr uk ru. Handling instructions

OPERATION & MAINTENANCE INSTRUCTIONS

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Transcription:

testo 540 Instruction manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com

Short manual testo 540 11 Short manual testo 540 Protection cap: Park position Light sensor Display Control keys Battery compartment (on rear) de it en fr es Basic settings Instrument off > press and hold 2s > select with ( ), confirm with ( ): Auto off function: OFF, ON Switching the instrument on Press. Switching the display light on (for 10s) Instrument on > press Select display size Instrument on > select with : lux, ftc Select display mode Instrument on > select with : Current reading > Hold: Readings are held > Max: Maximum values > Min: Minimum values Switching the instrument off: Instrument on >press and hold 2s.???? nl sv pt

12 Safety and the environment Safety and the environment About this document Please read this documentation through carefully and familiarise yourself with the product before putting it to use. Keep this document to hand so that you can refer to it when necessary. Hand this documentation on to any subsequent users of the product. Pay particular attention to information emphasised by the following symbols: Important. Avoid personal injury/damage to equipment Only operate the measuring instrument properly, for its intended purpose and within the parameters specified in the technical data. Do not use force. Never store the product together with solvents, acids or other aggressive substances. Only carry out the maintenance and repair work that is described in the documentation. Follow the prescribed steps when doing so. Use only OEM spare parts from Testo. Protecting the environment Take faulty rechargeable batteries as well as spent batteries to the collection points provided for them. Send the product back to Testo at the end of its useful life. We will ensure that it is disposed of in an environmentally friendly manner.

Specifications 13 Specifications Functions and use The testo 540 is an illuminance measuring instrument. It is normally used to measure illuminance, e.g. at workplaces. Technical data es fr en de Measurement data Sensor: Photo diode Parameters: Lux (lm/m 2 ), foot candle (lm/ft 2 ) Measuring ranges: 0...99999 Lux, 0...93000 ftc Resolutions: 1 Lux (0...19,999 Lux), 10 Lux (rest of range) 0.1 ftc (0...1,858.0 Lux), 1 ftc (rest of range) Accuracies (Nominal temperature 25 C, ±1 Digit): 3 % to reference Measuring rate: 0.5 s Further instrument data Protection class: IP40 Ambient conditions: 0...50 C, 32...122 F Storage/transport conditions: -40...70 C, -40...158 F Voltage supply: 2x 1.5 V type AAA Battery life: 200 h (without display light) Dimensions: 133x46x25 mm (inc. protection cap) Weight: 95 g (inc. batteries and protection cap) Directives, standards and tests EC Directive: 89/336/EEC Warranty Duration: 2 years Warranty conditions: see guarantee card???? nl sv pt it Test Equipment Depot - 800.517.8431 99 Washington Street, Melrose, MA 02176 TestEquipmentDepot.com

14 Product description Product description At a glance Protection cap: Park position Light sensor Display Control keys Battery compartment (on rear) First steps Inserting batteries: 1 To open the battery compartment, push the battery cover down. 2 Insert batteries (2x 1.5 V type AAA). Observe the polarity! 3 To close the battery compartment, push the battery cover back on. Basic settings (configuration mode): Adjustable functions Auto off function: OFF, ON (instrument switches off automatically if no key is pressed for 10 minutes) 1 When switching the instrument on, press and hold until and appear on the display (configuration mode). - The adjustable function is displayed. The current setting flashes. 2 Press ( ) several times until the desired setting flashes. 3 Press ( ) to confirm the input. - The instrument changes to measuring mode.

Using the product 15 Using the product de To guarantee correct readings: Hold the instrument horizontally so that the light sensor is directed upwards. Switching the instrument on: Press. - Measuring mode is opened. en fr es Switching the display light on: The instrument is switched on. Press. - The display light goes out automatically if no key is pressed for 10 seconds. Changing the parameter unit: Press until the desired unit appears. Adjustable units lux ftc Changing the display view:???? nl sv pt it Adjustable views Current reading Hold: Readings are held. Max: Maximum values since the instrument was last switched on or last reset. Min: Minimum values since the instrument was last switched on or last reset. Press several times until the desired view appears. Resetting Max/Min values: 1 Press several times until the desired view appears. 2 Press and hold until ---- appears. 3 Repeat steps 1 and 2 for all values that are to be reset. Switching the instrument off: Press and hold until the display goes out.

16 Maintaining the product Maintaining the product Changing batteries: 1 To open the battery compartment, push the battery cover down. 2 Remove used batteries and insert new batteries (2x 1.5 V type AAA). Observe the polarity! 3 To close the battery compartment, push the battery cover back on. Cleaning the housing: Clean the housing with a moist cloth (soap suds) if it is dirty. Do not use aggressive cleaning agents or solvents!

Tips and assistance 17 Tips and assistance Questions and answers Question Hi Possible causes/solutions Readings outside the measuring range (too high: Keep to the permitted measuring range. Residual capacity <10 min: Change batteries. If we could not answer your question, please contact your dealer or Testo Customer Service.?? pt it es fr en de?? nl sv

18 Notes

Test Equipment Depot - 800.517.8431 99 Washington Street, Melrose, MA 02176 TestEquipmentDepot.com 0973.5400/02/Sh/dr/28.03.2007