Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range

Similar documents
Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range

Sound Attenuated Level 2. Enclosures. Features. Enclosures kva Range

Sound Attenuated Enclosures Level 1, Level 2 & Level 3. Features ENCLOSURES kva (B Series) Range

SOUND ATTENUATED ENCLOSURES

Cat C1C2 ENCLOSURES SOUND ATTENUATED ENCLOSURES LEVEL 1, LEVEL 2 & LEVEL (B Series) Range FEATURES

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

Modular Acoustic Enclosures

Modular Acoustic Enclosures

Modular Acoustic Enclosures

ENCLOSURES. WEATHER PROTECTIVE and SOUND ATTENUATED. three levels of sound attenuation. D40-6 to D200-2 D40-6s to D100-6S.

C13/C15/C18 Sound Attenuated Enclosures. Features. Enclosures. U.S. Sourced Diesel Generator Set kw 60 Hz

Enclosures. Weather Protective and Sound Attenuated Enclosures D40-6 to D200-2 D40-6S to D100-8S. Features

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

C13 / C15 / C18 SOUND ATTENUATED ENCLOSURES

Enclosures. Options Caterpillar yellow or white paint Integral dual wall fuel tank base for total fluid containment (fuel, oil and coolant)

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

Modular Acoustic Enclosures

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

DIESEL GENERATOR SET DE220E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

DIESEL GENERATOR SET DE165E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

DIESEL GENERATOR SET. DE22E3 (B Series) Output Ratings. Technical Data

Bore mm 4.0 in Displacement 5.7 L 350 in³ Stroke 88.4 mm 3.48 in Compression Ratio 9.4:1

Hydraulic electronic unit injection

Generator Set Specifications 100 ekw (125 kva)

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Flexible, Reliable, Connected Power

Continuous, Prime, Standby, Mission Critical

Generator Set Specifications 480 ekw 600 KVA

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

RENTAL XQ400 SOUND ATTENUATED. 50/60 Hz FEATURES

including r installations. Backed by the worldwide l provide the reliabi Prime LEHE1073

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Generator Set Specifications 320 ekw (400 kva)

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

STANDBY 200 ekw 250 kva

STANDBY 484 ekw 605 kva 50 Hz 1500 rpm 400 Volts

Aftercooler (Separate Circuit) N/A N/A

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

Generator Set Specifications 60 ekw (75 kva)

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

like mission critical Backed by the worldwide l provide the reliabi Mission Critical LEHE1075

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

Specifications. 3406C Generator Set Electric Power

DIESEL GENERATOR SETS

220 to volts. Electronic unit injection

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

Specifications. Cat XQP150 Rental Generator Set. Prime 120 kw, 150 kva 50/60 Hz Switchable EU Stage IIIA. Prime kw (kva)

Voltage 220 to or 1800 RPM

3412C Generator Set Electric Power. Specifications. Benefits and Features

Engine Specifications C32 ACERT TA, V-12, 4-stroke Water-cooled Diesel. Compression Ratio 15.0:1 Turbocharged Aftercooled.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Specifications. C13 Generator Set Electric Power

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

Expert Design...Trusted Power

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

STANDBY 250 ekw 313 kva 60 Hz 1800 rpm 208 Volts

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

XQ80 RENTAL. 60 Hz FEATURES

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

400 to 11,000 Volts. Standby, Prime, Continuous

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

STANDBY 200 ekw 250 kva

Voltage 220 to or 1800 RPM. Engine Specifications C32 TA, V-12, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in)

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

C32 ACERT Generator Set Electric Power

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

Cat 3412 Diesel Generator Sets

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Cat C32 Diesel Generator Sets

Cat C32 Diesel Generator Sets

UNIVERSAL PRODUCT RANGE. Performance I Durability I Serviceability

STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

Cat C32 Diesel Generator Sets

DIESEL GENERATOR SET FEATURES

power moving forward KVA RANGE Performance I Durability I Serviceability

The kva RAnge

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 400 ekw 500 kva

Transcription:

Sound Attenuated Level 2 24 220 kva Range The sound attenuated Level 2, factory installed enclosures incorporate internally mounted critical level silencers. They are the premium enclosure offering for this range, designed for safety and aesthetic value on an integral fuel tank base. Extremely durable and weather resistant, these enclosures are designed to resist corrosion and handling damage. Image shown may not reflect actual configuration The enclosures are the result of continuing research and development by our specialist acoustic engineers. These enclosures reduce sound levels to comply with the Stage 2 levels of the European Community Directive 2000/14/EC which became effective January 3, 2006. Features Durable and Robust Construction Manufactured from galvanized steel Advanced powder-coated paint finish Single-piece main roof Base frame extends beyond enclosure, protecting against handling damage Minimal external fixings exposed to environment Zinc-plated fasteners Corner posts and air handling units manufactured from high-grade engineering thermoplastic Security and Safety Secure, lockable doors prevent unauthorized access to control panel, fuel fill, and battery Emergency stop button mounted on exterior, convenient to control panel Cooling fan and battery charging altenator fully guarded Excellent Service and Maintenance Access Side-hinged doors on both sides of the enclosure incorporate lift-off hinges at 45 Radiator fill via removeable, flush-mounted rain cap fitted with compression seal Lube oil cooling water drains piped to baseframe side rail, on exterior Removable end panels allow access to radiator, exhaust outlet, and alternator rear Doors positioned for optimum access of frequently serviced items Transportability Optional tested and certified lifting arch Lifting and drag points on base frame facilitate handling from both sides LEHE0788-05 Page 1 of 5

DE33E0 DE33E3 DE50E0 DE50E2 DE55E0 DE55E2 DE65E0 DE65E3 DE88E0 DE88E3 DE110E2 DE110E3 DE150E0 DE165E0 Prime 93 61 62 67 68 76 77 61 63 67 69 77 79 Standby 93 61 62 67 68 76 77 61 64 67 70 78 80 Prime 94 59 61 65 67 75 77 Standby 94 60 62 66 68 76 78 Prime 93 57 58 63 64 74 74 60 61 66 67 76 77 Standby 93 57 58 63 64 74 75 60 62 66 68 77 78 Prime 90 56 56 62 62 74 75 Standby 90 56 57 62 63 74 75 Prime 93 57 58 63 64 74 75 60 62 66 68 77 78 Standby 93 57 59 63 65 74 76 61 62 67 68 77 79 Prime 56 57 62 63 74 74 Standby 56 57 62 63 74 75 Prime 93 58 60 64 66 74 76 61 63 67 69 77 79 Standby 93 58 61 64 67 75 77 62 64 68 70 78 80 Prime 91 58 59 64 65 75 76 Standby 91 58 59 64 65 75 76 Prime 92 58 59 64 65 76 76 61 61 67 67 78 79 Standby 92 58 60 64 66 76 77 61 62 67 68 79 79 Prime 97 61 61 67 67 79 79 Standby 97 61 62 67 68 79 79 Prime 96 62 63 68 69 80 81 65 65 71 71 84 84 Standby 96 63 64 69 70 80 81 65 66 71 72 84 84 Prime 97 61 62 67 68 79 79 Standby 97 62 62 68 68 79 79 Prime 97 60 61 66 67 76 76 61 61 67 67 77 77 Standby 97 60 61 66 67 76 77 61 61 67 67 77 78 Prime 97 59 59 65 65 74 74 61 62 67 68 77 77 Standby 97 59 59 65 65 74 75 62 62 68 68 77 78 LEHE0788-05 Page 2 of 5

DE165E3* DE175E3* DE200E0 DE200E3* DE220E0 Single-phase DE26E0S DE26E3S DE40E0S DE40E2S DE50E0S DE55E3S DE90E2S DE90E3S Prime 93 61 62 67 68 76 77 61 63 67 69 77 79 Standby 93 61 62 67 68 76 77 61 64 67 70 78 80 Prime 94 59 61 65 67 75 77 Standby 94 60 62 66 68 76 77 Prime 93 57 58 63 64 74 74 60 61 66 67 76 77 Standby 93 57 58 63 64 74 75 60 62 66 68 77 78 Prime 90 56 56 62 62 74 75 Standby 90 56 57 62 63 74 75 Prime 93 57 58 63 64 75 76 60 61 66 67 78 78 Standby 93 57 58 63 64 75 76 60 61 66 67 78 78 Prime 91 58 59 64 65 75 76 Standby 91 58 59 64 65 75 76 Prime 96 62 63 68 69 80 81 65 65 71 71 84 84 Standby 96 63 64 69 70 80 81 65 66 71 72 84 84 Prime 97 61 62 67 68 79 79 Standby 97 62 62 68 68 79 79 Levels in accordance with European Noise Directive (2000/14/EC). Prime 58 59 64 65 73 74 Standby 58 59 64 65 74 74 Prime 58 59 64 65 74 74 Standby 58 59 64 65 74 75 Prime 97 62 62 68 68 78 78 65 65 71 71 81 81 Standby 97 62 63 68 69 78 78 65 65 71 71 81 81 Prime 59 60 65 66 74 75 Standby 59 60 65 66 74 75 Prime 97 62 64 68 70 78 79 Standby 97 63 64 69 70 78 79 Levels in accordance with European Noise Directive (2000/14/EC). *Available as DTO only. LEHE0788-05 Page 3 of 5

Weights and Dimensions Generator Set Model A: B: C: D*: Fuel Capacity: l (US gal) Weight: kg (lb) DE33E0 2120 (83.5) 980 (38.6) 1519 (59.8) 716 (28.2) 161 (43.0) 1002 (2209) DE33E3 2120 (83.5) 980 (38.6) 1519 (59.8) 716 (28.2) 161 (43.0) 1002 (2209) DE50E2 2300 (90.6) 1132 (44.6) 1519 (59.8) 761 (30.0) 219 (58.0) 1237 (2727) DE50E0 2300 (90.6) 1132 (44.6) 1519 (59.8) 761 (30.0) 219 (58.0) 1237 (2727) DE55E0 2300 (90.6) 1132 (44.6) 1519 (59.8) 761 (30.0) 219 (58.0) 1229 (2709) DE55E2 2300 (90.6) 1130 (44.5) 1525 (60.0) 761 (30.0) 219 (58.0) 1277 (2815) DE65E0 2300 (90.6) 1132 (44.6) 1519 (59.8) 761 (30.0) 219 (58.0) 1249 (2754) DE65E3 2300 (90.6) 1130 (44.5) 1519 (59.8) 761 (30.0) 219 (58.0) 1319 (2908) DE88E0 2300 (90.6) 1130 (44.5) 1519 (59.8) 761 (30.0) 219 (58.0) 1416 (3122) DE88E3 2770 (109.1) 1130 (44.5) 1530 (60.2) 893 (35.2) 250 (66.0) 1554 (3426) DE110E2 2770 (109.1) 1130 (44.5) 1530 (60.2) 893 (35.2) 250 (66.0) 1615 (3560) DE110E3 2770 (109.1) 1130 (44.5) 1530 (60.2) 893 (35.2) 250 (66.0) 1744 (3845) DE150E0 3520 (138.6) 1130 (44.5) 1809 (71.2) 1143 (45.0) 349 (92.2) 1918 (4228) DE165E0 3520 (138.6) 1130 (44.5) 1809 (71.2) 1143 (45.0) 349 (92.2) 2016 (4445) DE165E3** 3520 (138.6) 1130 (44.5) 1809 (71.2) 1143 (45.0) 349 (92.2) 2158 (4758) DE175E3** 3520 (138.6) 1130 (44.5) 1809 (71.2) 1143 (45.0) 349 (92.2) 2158 (4758) DE200E0 3520 (138.6) 1330 (52.4) 1809 (71.2) 1078 (42.4) 418 (110.0) 2198 (4836) DE200E3** 3520 (138.6) 1330 (52.4) 1809 (71.2) 1078 (42.4) 418 (110.0) 2248 (4956) DE220E0 3520 (138.6) 1330 (52.4) 1809 (71.2) 1078 (42.4) 418 (110.0) 2238 (4934) *Clearance required on both sides of set. **Available as DTO only. Weight with lube oil and coolant, no fuel. LEHE0788-05 Page 4 of 5

Weights and Dimensions Generator Set Model Single-phase A: B: C: D*: Fuel Capacity: l (US gal) Weight: kg (lb) DE26E0S 2120 (83.5) 980 (38.58) 1519 (59.8) 716 (28.2) 161 (43.0) 991 (2185) DE26E3S 2120 (83.5) 980 (38.58) 1519 (59.8) 716 (28.2) 161 (43.0) 991 (2185) DE40E0S 2300 (90.6) 1132 (44.7) 1519 (59.8) 761 (30.0) 219 (58.0) 1247 (2749) DE40E2S 2300 (90.6) 1132 (44.7) 1519 (59.8) 761 (30.0) 219 (58.0) 1199 (2643) DE50E0S 2300 (90.6) 1132 (44.7) 1519 (59.8) 761 (30.0) 219 (58.0) 1315 (2899) DE55E3S 2300 (90.6) 1130 (44.5) 1519 (59.8) 765 (30.1) 219 (58.0) 1355 (2987) DE90E2S 2770 (109.1) 1130 (44.5) 1530 (60.2) 893 (35.2) 250 (66.0) 1613 (3556) DE90E3S 2770 (109.1) 1130 (44.5) 1530 (60.2) 893 (35.2) 250 (66.0) 1653 (3644) *Clearance required on both sides of set. Weight with lube oil and coolant, no fuel. LEHE0788-05 (09/16) www.cat-electricpower.com 2016 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. CAT, CATERPILLAR, their respective logos, Caterpillar Yellow, the Power Edge trade dress as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.