Valve Manifolds. Series сайт: эл. почта:

Similar documents
Valve Manifolds. Series Fielbus Electronics - 51

501 series. Aluminium, E-coating treatment

2012 Series Solenoid Pilot Actuated Valves

503 series. Level C to +50 C spool & sleeve metal-to-metal sealing. Aluminium, E-coating treatment

Servotronic Digital 615 Series

SHORT STROKE CYLINDERS Ø 8 to 100 mm - single and double acting with single/double rod, antirotation device

VarioDrive C, technical information. VarioDrive C, size 084. VarioDrive C, size 112. VarioDrive C, size 150

Двойной электромагнитный клапан DMV/12, DMV-D/12, DMV-DLE/12 DUNGS

TOPAS PMW-basic Hot water meter

Электромагнитные клапаны для пара Burkert

2035 Series Solenoid Pilot Actuated Valves

Sub-Base Mounted Valves to ISO 5599/2 Fielbus Electronics - 239

Пневмоострова Burkert

сайт: почта:

Описание на системы датчиков воздушного зазора. Модель 4000

2005 / 2012 / 2035 Series

2012 Series Solenoid Pilot Actuated Valves

PST-100. Instruction Manual English Version. Please read carefully before use

сайт: эл. почта:

Модульные клапаны Burkert

Kolmeks. Инструкция по эксплуатации (eng)

Электромагнитные клапаны для агрессивных и чистых сред Burkert

ISO 5599/ Series Technical and Operating Data

Каталог продукции Buhler

Valve Manifolds Series

Electrical Interface Dimensional Drawings Connector Kits

FESTO. Документация. Линейные приводы DGC-K (eng) По вопросам продаж и поддержки обращайтесь:

Каталог продукции DUNGS

Pressure transmitterses. По вопросам продаж и поддержки обращайтесь: Единый адрес для всех регионов:

Kolmeks. Инструкция по эксплуатации (eng)

Регулирующие клапаны с электроприводом Burkert

Hydraulic Flanges SAE J 518 С & ISO 6164

2005 Series Solenoid Pilot Actuated Valves

PNEUMATIC VALVE MANIFOLDS 11 mm - Series 501 M7 or with push-in fittings Ø6 mm

FESTO Документация Поворотные приводы DRRD

A K 3 E D G

FESTO. Документация. Стандартные распределители VSVA с индивидуальным подключением. По вопросам продаж и поддержки обращайтесь:

HONDA. Инструкция по эксплуатации (eng.)

english Technology in the future SL800 Series

Каталог продукции. Гидравлические борты и подъемники. Единый адрес для всех регионов:

Каталог продукции SULZER

По вопросам продаж и поддержки обращайтесь:

По вопросам продаж и поддержки обращайтесь:

2002 Series Solenoid Air Pilot Actuated Valves

503 Series Solenoid Pilot Actuated Valves

Today Numatics is proud to be a part of the Industrial Automation Division of Emerson Electric Co.

MT4-024/MT4-230 MT8-024/MT8-230

501 SERIES. 501 Series Directional Control Valve Platform. Featuring Higher Flow in a Compact Valve Package. Commissioning Capabilities

Line-Mounted Valves L Series. L1 / L2 Series Overview L22 BA4 52. Valve Function. Function PP6 = PP7 = JA4* = JJ4* = JJ5* = JJ6* = JJ7* =

I23 RD P 16N 00

VersaFlow Mag 3000 Electromagnetic Flow Sensor Technical Datasheet. Specification

DL1000 Electrode Mountings

VALVES. V40/V41 Mini ISO Star Valves 2x3/2, 5/2 and 5/3, Solenoid and Pilot Actuated ISO / VDMA Size 18 mm

503 series. GENERAL Operating pressure

Sartolab P The new way for reliable sterile filtration of cell culture media

CABINET MOUNTING. 501 series. Aluminium or stainless steel AISI 316L

V44/V45 series, 2 x 3/2, 5/2 & 5/3 Mini ISO Valves

CABINET MOUNTING. 501 series

HERION. MINI ISO VALVES Size 18 mm, V40 / V41 SERIES Size 26 mm, V44 / V45 SERIES. Flexible subbase system with a wide range of accessories

Combics Weighing Platforms CAAPP...

Solenoid Pilot Actuated Valves

Nugget 40, V08 series

VAL-138. Valves. Electrical Details for Solenoid Pilot. Operating Pressure

Series 581 ISO Pneumatic Directional Control Valves

Section 6. Four Station Nugget 30 High Flow Micro Valve with 25-pin D connector and Pneufit Fittings

FIELDBUS ELECTRONICS 580 Electronics (Series : M7 to 1/2 (G or NPT) or with push-in fittings Ø4 to 10 mm)

02/97 N/** Our policy is one of continued research and development. We therefore reserve the right to amend,

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

ROSS CONTROLS. Base Mounted Valves. and Serial Bus Communication

VALVES. V44/V45 Mini ISO Star Valves 2x3/2, 5/2 and 5/3, Solenoid and Pilot Actuated ISO / VDMA Size 26 mm

MARK 8 SERIES. direct solenoid actuated valves MARK 8

Valve Islands, V22 Series Sub-base Mounted 2 x 3/2, 5/2 and 5/3 Valves Solenoid Actuated with Wireway

MARK 15 SERIES. direct solenoid actuated valves

Solenoid valves VUVS/valve manifold VTUS, NPT

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Metric Series Overview

Manifold Specifications

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Inch Series Overview

Technical Information Features Fast Response - Bubble Tight Sealing Small Size - 4 Inches High Single Solenoid - Only 3 Moving Parts Pilot Interchange

Series 77 & 78. Compact & Modular Valves. solutions. Series 77 - Compact Valves. Series 77 - Sub-D. Series 77 - Fieldbus

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

Solenoid valves MH2/MH3/MH4, fast-switching valves

Sentronic LP IO-Link CLASS A 617 Series. Proportional Technology

Zone Safety Manifold. Fielbus Electronics Availability, design and specifications are subject to change without notice. All rights reserved.

Control block VOFA with safety function

AUTO STAR with central connector M12x1

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Manifold Specifications Stacking Type

SOLENOID VALVES AND PNEUMATIC VALVES

Simultaneous Electrical / Pneumatic Connection to Manifold 1/4 or 6mm Integral Push-In Fittings. AC or DC Circuit Board

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Asia Pacific Express Catalog. Machine Automation

Assembly kits (501 Series/502 Series/503 Series) 25 Pin Sub-D Connector Kit

Valve terminals MPA-L

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Pneumatic. PVD Everdure Ceramic Valves

ATEX Series 502 Valve. Islands Series 502, ATEX Group II, Zone 2 and 22, Category 3 GD. Features Specifications...

Isonic Mod 3 Series 3000/ /2, 3/2 Direct - 4/2 Single & Double Solenoid Valves

42 Series MAConnect TM. 42 Series Plug-In Manifold

SVR10 SVA10. External Pilot air specification. Conventional specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized.

Valvair Sprint TM Pneumatic Valves Solenoid & Pilot-Operated Directional Spool Valves. Catalog VAL-VS-E/USA April 2004

Transcription:

Valve Manifolds Series 0 Архангельск (88)6-90-7 Астана (77)77- Астрахань (8)99-6-0 Барнаул (8)7-0-60 Белгород (7)0--6 Брянск (8)9-0- Владивосток ()9-8- Волгоград (8)78-0-8 Вологда (87)6--9 Воронеж (7)0--7 Екатеринбург ()8--89 Иваново (9)77--06 Ижевск ()6-0-8 Казань (8)06-0-8 Калининград (0)7-0-8 Калуга (8)9--67 Кемерово (8)6-0-6 Киров (8)68-0-0 Краснодар (86)0-0-90 Красноярск (9)0-6-6 Курск (7)77--0 Липецк (7)-0-8 Магнитогорск (9)-0- Москва (9)68-0-70 Мурманск (8)9-6-9 Набережные Челны (8)0-- Нижний Новгород (8)9-08- Новокузнецк (8)0-6-8 Новосибирск (8)7-86-7 Омск (8)-6-0 Орел (86)-- Оренбург ()7-68-0 Пенза (8)--6 Пермь ()0-8-7 Ростов-на-Дону (86)08-8- Рязань (9)6-6-6 Самара (86)06-0-6 Санкт-Петербург (8)09-6-0 Саратов (8)9-8-78 Севастополь (869)--9 Симферополь (6)67--6 Смоленск (8)9-- Сочи (86)-7- Ставрополь (86)0-6- Сургут (6)77-98- Тверь (8)6-- Томск (8)98-- Тула (87)7-0-9 Тюмень ()66--8 Ульяновск (8)--9 Уфа (7)9-8- Хабаровск ()9-98-0 Челябинск ()0-0-6 Череповец (80)9-0-6 Ярославль (8)69--9 сайт: http://asco.nt-rt.ru эл. почта: ach@nt-rt.ru

General Information 0 Valve Series belong to the Numatics Valve Generation 000. With up to outputs and 96 inputs., depending on the protocols used, they fulfill all requirements of automation. Characteristics: - Modular reality, true plug & play flexibility in design. mm wide valves. - Strong and light due to valve housing made of aluminium. - Equipped with the famous Numatics lapped spool and sleeve assembly: - Insensitive, self-cleaning spool made of stainless steel with air bearing effect by air entrained between spool and sleeve ( µm air clearance), typical service life of more than 00 million cycles. - Can operate with different pressures at the same time within one valve, independent of flow direction. - Available as -port., - and -pos. valve. - Exchange of valves without dismounting valve manifold. - Worldwide support by Numatics subsidiaries and distributors in almost all countries of the world. -port., - and -pos. valves, single or double solenoid pilot actuated Flow capacity: 80 l/min ANR Individual base mount or manifold mount Low-wattage solenoids polarity insensitive with surge suppression Plug-in manifolds with internal wiring by Z-Board plug-in system Integral recessed gaskets between base and valve as well as between the manifolds Interchangeable cartridge fittings to accommodate various tube sizes Simple conversion from internal to external pilot air supply Modular plug-together Fieldbus electronics Designed to meet IP6/NEMA

Contents Description Page General Information... Spool and Sleeve Assembly Manifold with Plug-in Technical Data Operating Data... Sandwich Pressure Regulators General Information... Dimensions...6 Completely Assembled Manifolds with Multipole Connection...7 -D Drawings...8 Accessories...9 Dimensions / Weight...6 Overview...6..6 Spare Parts Plates (sandwich pressure regulator, sandwich speed control, shut-off sandwich plate, sandwich pressure block)... 66-67 Blank station plate, Blocking discs, Covers, Plug...68 End Plate Kits...68 Valves and sandwich pressure regulators...69-70 Manifold Assemblies Kits Z-Boards, Ribbon Cable Assembly Kit....7 Mid-Station Supply and Exhaust Blocks...7 Conversion of Pilot Air Supply...7 Completely Assembled Manifolds with Fieldbus Electronics G...76 -D Drawings............................................. 77 Fieldbus Systems (protocols).............................. 8..97 Input / Output Modules.................................... 99..0 Dimensions (I/O Assembly with G Electronics)...06 How to Order - 0 mm Series.... 0-- How to configure & Order G Electronics...9-0

Technical Data Operating Data Manifolds of 0 series valves are equipped with integral electrical plug-in allowing an easy exchange of single components without dismounting the manifold. Z-Board eliminates internal wiring. Manifolds are available either with threaded ports or with push-in fittings. Bottom supply ports are only available threaded. Common air exhaust. End plates are available with integral mufflers. Easy conversion from internal to external pilot air supply. Technical Data -port., - and -pos. valves 0 Flow capacity [at 6 bar, p bar] 00 l/min ANR Operating pressure range: Vacuum to 0 bar Pilot pressure range:,8 to 8, bar Ambient temperaturre range -0 C to +0 C Material Body: Other parts: Static seals: Finish: Operating Data Aluminium Stainless steel, steel, aluminium alloy or plastic NBR Anodised or varnished port., - and -pos. valves 0 00% ED: VDC 0-0 VAC 0/60 Hz Power (Watt):.. Response time [ms] energise de-energise energise de-energise -port., -pos., single actuated, spring return: 67 70 -port., -pos., double actuated, detented: 7 - - -port., -pos., double actuated, spring centered: 7 80

Sandwich Pressure Regulators General Information For single as well as double sandwich pressure regulators are available. With single sandwich pressure regulators, pressure supply is regulated via port. This is carried out independently of other valves on the manifold. With double sandwich pressure regulators, pressure supply is regulated via ports and, i. e. each cylinder port can be regulated individually. The selected pressure can be read via a gauge, either mounted inline or on a 90 swivel elbow. Sandwich Pressure Regulators 0 series:type RS / RD / RC / RQ / RE / RT When ordering a valve with regulator mounted on a manifold, list the valve unit model number only and include the mounting requirements with the regulator. Specify Assembled EXAMPLE ORDERS: Valve unit only: Regulator and mounting: Type RS BA00K00000 RSZJN00000 ASSEMBLED Single pressure from a single supply Symbols RS RD RC Dual pressure from a single supply Non-relieving: taps downstream pressure if upstream is exhausted RQ RE RT Relieving: exhausts pressure in cylinder if upstream pressure is exhausted External regulator - separate pressures to ports and. Two-pressure selector used for multi-pressure applications Type RS Single pressure from a single supply. Type RD Dual pressure from a single supply. Type RC Type RC is non-relieving: Traps downstream pressure if upstream pressure is exhausted. Type RE External regulator - separate pressures to ports and.. Type RQ Type RQ is relieving: Exhausts pressure in cylinder if upstream pressure is exhausted. Type RT Two-pressure selector used for multi-pressure applications.

Sandwich Pressure Regulators Dimensions Single or Double Sandwich Pressure Regulator mm Hex 6 7 8 9 0 D E C B A I H F G Dimensions 0 series [mm] Type A B C D E F G H I Weight approx. [kg] Single regulator 77. 0.7 9. 8.6 0..0 0.6 0.70 Double regulator 77.. 9. 8.6 0..0 0.6 7. 0.99 6 - Fielbus Electronics

General Information on Multipole Systems FEATURES Solenoid air operated valve manifolds for connection to a control system (PLC) with a multiwire cable for simple wiring. Electrical connection with a or 7 pin Sub-D connector or a, 9 or 6 pin round connector. Harting on request. Internal wiring by Z-Board plug-in system. Plug-together flexibility due to different assembly and wiring options. Designed to meet IP6 / NEMA with round connector or terminal strip. These protection classes allow direct incorporation of the 000 series manifold into a machine, close to the actuators and enable an increased number of production cycles. Manifold delivered assembled according to customer specifications. COMBINATIONS Modules of up to valves can be grouped together. The maximum number of valves depends on the type of electrical connection chosen: - pin Sub-D connector : max. solenoids - 7 pin Sub-D connector : max. solenoids - Terminal strip: max. solenoids - pin round connector: max. 8 solenoids - 9 pin round connector: max. solenoids - 6 pin round connector: max. solenoids Optional mixing of: - All functions of dual -position, -ported, -position single or double actuated and -ported, -position valves. - Pressure separation plate and intermediate pressure supply module. The valve manifolds are intended for frame. Technical Data Electrical data Node power: Voltage: V DC +- 0% Operating data Temperature range: -0 C to +0 C Humidity: air or inert gas ISO 87 Level 7.. Protection: IP 6 or NEMA Configuration data Solenoid coil outputs: Max. Fielbus Electronics - 7

Terminal Strip. Sub-D, and Round Connector Options (8) Phoenix Quick Connect Terminal Strip Terminal Strip Option Converter Board Assembly 0 Double Solenoid Air Pilot Valve Unit Single Pressure Sandwich Regulator (Double Regulator also available) Backplane Circuit Board Assembly Left End Mounting Bracket Assembly Terminal Strip Housing 0 Single Solenoid Air Pilot Valve Unit Manifold Mounting Screws Sub-D Option Z-Board Blank Station Plate Manifold Gasket Mounting Support Standoff Sub-D Housing Assembly Left End Mounting Bracket 8 - Fielbus Electronics Left End Plate Assembly Round Pin Option Round Connector Board Assembly & 6 Pin Connector Assembly Left End Mounting Plate Sandwich Speed Control

Multipole Systems Accessories Accessory Description Order Code pin female SUB-D connector, according to DIN 700, straight cable outlet (IP 0) (série 000) w/ cable m 8800 m 88006 0 m 88006 pin female SUB-D connector, elbow cable outlet (série 000) w/ cable m 880090 m 8876 7 pin female SUB-D connector, according to DIN 700, straight cable outlet (IP 0) (série 000) w/ cable m 88007 m 880076 0 m 88008 9 pin female M connector, straight w/o cable 8860 w/ cable m 88606 9 pin female M connector, 90 elbow w/o cable 8860 w/ cable m 88607 pin female M connector (IP 6) w/o cable w/ cable 0-879-K m 0-960-0m m 0-960-0m 0 m 0-960-0m 6 pin female M7 connector (IP 6) w/ cable 0 m 0-7E-0m Fielbus Electronics - 9

Multipole Systems Accessories Pin no. 7 PIN SUB-D according to DIN 700 Order Codes: 88007 880076 88008 SUB-D Order Codes: 880090 8876 PIN SUB-D according to DIN 700 Order Codes: 8800 88006 88006 PIN ROUND M Order Code: 0-960-xxm 9 PIN ROUND M Order Codes: 88606 88607 6 PIN ROUND M7 Order Code: 0-7E-0m white white-green white white purple white brown white-yellow brown brown red brown green white-grey green green grey green yellow green yellow yellow red-blue yellow grey yellow grey grey green grey 6 pink yellow-black pink pink blue pink 7 blue grey blue blue grey-pink blue 8 red yellow-red red red white-green red 9 black pink black black white-yellow black 0 purple yellow-blue purple purple white-grey purple grey-pink orange grey-pink grey-pink black pink-brown red-blue khaki red-blue green-yellow yellow-green white-pink white-green blue white-green yellow-brown white-green brown-green white-brown brown-green brown-green brown-green white-yellow white-black white-yellow white white-yellow 6 yellow-brown purple yellow-brown yellow yellow-brown 7 white-grey white-pink white-grey pink white-grey 8 grey-brown white-red grey-brown grey-brown grey-brown 9 white-pink white-purple white-pink brown red-blue 0 pink-brown white-blue pink-brown grey-pink white-blue blue white-blue white-blue brown-blue white brown-blue brown-blue white-red red white-red white-red brown-red brown brown-red brown-red white-black black white-black white-black 6 brown-black yellow-green 7 grey-green 8 yellow-grey 9 pink-green 0 yellow-pink green-blue yellow-blue green-red yellow-red green-black 6 yellow-black 7 grey-blue 9 8 7 6 0 98 7 6 Pin 7 PE Pins -6 COMMON Pins - Coils 7 6 0 9 8 7 6 0 60 - Fielbus Electronics 0 98 7 6 Pin PE Pins - COMMON Pins - Coils 0 9 8 7 6 Pin PE Pin COMMON Pins -0 Coils View from solder side 0 7 8 9 9 8 6 7 Pin PE Pin 6 COMMON 6 Pin 6 PE Pins - COMMON Pins - Coils

Dimensions Manifold Assembly Note: For Fieldbus Electronics dimensions, see page: 09 Dimensions [mm] A B C D E F G H J K L M N O P Q R 77.0 0.0.0.0.0 9.0 7.0.0 0.0.0.0 8.0 0.0 69.0 0.0 7.0.0 S T U V W X Y Z AA Weight +... kg (0 stations) approx. [kg] per station 6.0...6 78.0.0 6.0 7.0..00 0.60 Fielbus Electronics - 6

How to order: (example). Multipol Module Multipole Connections Overview AK J B D 0000 G STD Configurator - CAD Files Electronic System F = Terminal strip - 6 T = Terminal strip - J = pin SUB-D M = 7 pin SUB-D P = pin round M connector Q = 9 pin round M connector S = 6 pin round M7 connector & pin round M connector STD = MUF = A06 = D = D = X = Options Standard Muffler in end plates End plate with ports on left end only, mounting plate only on right end A06 + MUF MUF + X External pilot supply B = Series Number of Valve Stations ) A = I = 9 Q = 7 Y = B = J = 0 R = 8 Z = 6 C = K = S = 9 = 7 D = L = T = 0 = 8 E = M = U = = 9 F = 6 N = V = = 0 G = 7 O = W = 6 = H = 8 P = 6 X = 7 = N = G = Port Type NPTF (contact us) G thread Maximum Solenoid Outputs AK F AK T AK J AK M AK P AK S 6 8 ) Note: Maximum number of valve stations is determined by the electrical / electronic connection type the valve type: Single solenoid pilot actuated valves up to the maximum solenoid outputs allowed by the electrical connection type or a combination of single and/or double solenoid actuated valves not to exceed the maximum number of outputs allowed. Example: 6 single and double solenoid actuated valves have in total 6 solenoid outputs. This is the maximum amount permitted for the terminal strip version. ( AKF ). 6 - Fielbus Electronics End Plate Port Size = Port type N or G Port = / Port / = / X = Multiple valve groups resulting in different standard end plate port size (0 = /)

. Valve Model Number Series = Multipole Connections Valves Overview BB Z6 M G 000 6 Voltage 00 = Blank station plate 60 = V DC 6 = V DC Port Size of Base 0 = G /8 or NPTF or valve w/o manifold = G / or NPTF or valve w/o manifold X X Options 000 = Without option B = Locking override M = Without manual override Further options on request O = G = N = Port Type of Bases Without base G thread NPTF thread Actuator BA = Single actuated and spring return flush non-locking manual override BB = Double actuated, flush non-locking manual override 00 = Manifold w/o valve (blank station) K = M = O = Wiring Options Plug-in, AC with LED Plug-in, DC with LED Blank station plate Function 0 = -port., -pos. valve X = -port., -pos. valve, open center, dual pressure X 6 = -port., -pos. valve, closed center X P = Indicates blank station plate X Ribbon cable option must be used for manifold assemblies that exceed 6 solenoids. (7th and 8th digit of valve order code) I/I6... 0//... BA -ported, -pos. valve, spring return Symbols Mounting 00 = Valve unit only 0 = With sandwich speed control Z = Manifold block with side and bottom ports, single solenoid, Z-Board Z = Manifold block with side and bottom ports, double solenoid, Z-Board Z = Z with speed control Z6 = Z with speed control R = Z with ribbon cable connector R = Z with ribbon cable connector R = Z with ribbon cable connector R6 = Z6 with ribbon cable connector N = M separation V DC I/I6... 0//... I/I6... 0//... R/R6... 0//... BB BB* BB6 -ported, -pos. valve, detented -port., -pos. valve, open center, dual pressure -port., -pos. valve, closed center Fielbus Electronics - 6

. Sandwich Pressure Regulator Model Number Sandwich Pressure Regulators Overview RS Z J G 000 00 Series = Options 000 = Standard H = Without gauge 6N = Jumper on end 6P = Jumper on end Further options on request = = Port Size of Base 0 G /8 or NPTF or valve w/o manifold X G / or NPTF or valve w/o manifold X O = Q = K = P = Port Type of Bases Without base G thread Plug-in fittings NPTF thread Regulator Type RS = Single pressure to port RD = Dual pressure to ports and RC = Dual pressure with non-relieving checks RQ = Dual pressure with relieving checks RE = Dual pressure to ports and RT = Two-pressure selector Pressure Range = 0.7 to 9 bar = 0. to bar = 0. to bar J = Wiring Option Plug-in receptacle Mounting 0 00 = Regulator unit only X 0 = With sandwich speed control X Z = Manifold block with side and bottom ports, single solenoid, Z-Board X Z = Manifold block with side and bottom ports, double solenoid, Z-Board X Z = Z with speed control X Z6 = Z with speed control X R = Z with ribbon cable connector X R = Z with ribbon cable connector X R = Z with ribbon cable connector X R6 = Z6 with ribbon cable connector X Ribbon cable option must be used for manifold assemblies that exceed 6 solenoids. (7th and 8th digit of valve order code) 6 - Fielbus Electronics Single pressure from a single supply Symbols RS RD RC RQ Relieving: exhausts pressure in cylinder if upstream pressure is exhausted Dual pressure from a single supply RE External outlet regulator used with jumper plate for single or dual pressure Non-relieving: taps downstream pressure if upstream is exhausted RT Two-pressure selector used for multi-pressure applications

Multipole Connections Example Order Sandwich Pressure Regulators and Speed Control Type: RS / RD / RE / RT When ordering a valve with regulator mounted on a manifold and sandwich speed control, list the valve unit model number only and include the mounting requirements with the regulator and the speed control. Specify Assembled EXAMPLE ORDERS: Valve unit only: BA00M00006 Regulator with speed control and mounting: RSZJN00000 ASSEMBLED BA00M00006 Valve unit only (without manifold block) Standard sandwich pressure regulator RSZJN00000 Sandwich speed control ASSEMBLED Plug-in manifold assembly Note: Sandwich speed controls can only be used with single sandwich pressure regulators. Manifold assembly Multipole connection Shaded components are included in assembly kit (AK). Each valve station is listed in sequential order from left to right when facing the port side of the manifold as indicated. For valves and sandwich pressure regulators, see model number selection on pages X0-09- and ). Example order: ( Pin Sub-D). Assembly kit AKJBD0000NSTD. Valve Station = BAZMN0006 Station = BAZMN0006 Station = BBZMN0006 Station = BBZMN0006 ASSEMBLED Fielbus Electronics - 6

Accessories Sandwich Pressure Regulators accessory description order code 0, to bar 9-0 Regulator repair kit 0, to bar 9-0,7 to 9 bar 9- Gauge to max. bar - Gauge to max. bar -0 Adapter, port G/8 9-08 Retaining clip -6 66 - Fielbus Electronics

Spare Parts Sandwich Components Sandwich Speed Control Sandwich speed control for valves and regulators is equipped with an integral plug-in system. Sandwich speed control provide a variable restriction in ports and in order to control the cylinders extend and retract speed. To facilitate easy adjustment both screws are on the same side of the speed control. Note: Sandwich speed control can only be used with single sandwich pressure regulators. Single Solenoid Pilot Actuated, -port., -pos. Valve Single Sandwich Pressure Regulator Plug-in System Sandwich Speed Control Stud Manifold Block Accessory Description Order code C B A Sandwich speed control 9- D 7 6 8 9 0 EB B P XE () () () A () EA () X EB () P () EA () 0 Sandwich pressure block - Used to supply a separate pressure to a single valve station without needing blocking disks. Sandwich exhaust block - Used to isolate the exhaust of a single valve station from the manifold. - Allows faster exhaust response by re-routing. - Exhaust externally to the manifold. Assembly/disassembly of bar:, mm external hex key XE () EB EB() EB XE () XE () EB () () B P B () () B () A P () () P () EA A () () A X P() EA () X () X EA EA() 9-8 9-0 Fielbus Electronics - 67

Spare Parts Accessory Description Order Code Blank station plate (screw, blank station plate, O-ring, gasket) 9-8 0.87 (.0 mm) Blocking disks for port, / 9-9 Cover for end plate screw 7-96 cover 0-6 Cover for end plate with muffler screw 7-96 cover 0-7 Gasket for end plate cover -6 Muffler for end plate cover -098 Plug for conversion of pilot supply -90 Spare Parts End Plate Kits End plate kit End plate kits Order Code Weight Port / X/XE approx. [kg] Size / / /8 End plates with muffler.00 9-07 End plates without muffler.00 9-08 LH ports with muffler, RH mounting cover with pilot exhaust.00 9- LH ports without muffler, RH mounting cover with pilot exhaust.00 9-6 On request: with NPTF thread 68 - Fielbus Electronics

Spare Parts Valves Valve Model Number BB 00 M 0 000 6 Series = Voltage 60 = VDC 6 = VDC Port Size of Base = Valve w/o manifold Options 000 = Without option B = Flush Locking Override M = Without manual override Further options on request BA = BB = Actuator Single actuated and spring return flush non-locking manual override Double actuated, flush non-locking manual override Port Type of Bases 0 = Valve unit only Function = -port., -pos. valve = -port., -pos. valve, open center, dual pressure 6 = -port., -pos. valve, closed center Wiring Options M = Plug-in, DC with LED Mounting 00 = Valve unit only Ribbon cable option must be used for manifold assemblies that exceed 6 solenoids. (7th and 8th digit of valve order code) I/I6... 0//... I/I6... 0//... I/I6... 0//... BA BB BB* -ported, -pos. valve, spring return -ported, -pos. valve, detented -port., -pos. valve, open center, dual pressure Symbols R/R6... 0//... BB6 -port., -pos. valve, closed center Fielbus Electronics - 69

Sandwich Pressure Regulator Model Number Spare Parts Sandwich Pressure Regulators RS 00 J 0 000 00 Series = Options 000 = Standard H = Without gauge 6N = Jumper on end 6P = Jumper on end Further options on request Port Size of Base = Valve w/o manifold 0 = Without base Port Type of Bases Regulator Type RS = Single pressure to port RD = Dual pressure to ports and RC = Dual pressure with non-relieving checks RQ = Dual pressure with relieving checks Wiring Option J = Plug-in receptacle Mounting 0 00 = Regulator unit only X RE = Dual pressure to ports and RT = Two-pressure selector Pressure Range = 0.7 to 9 bar = 0. to bar = 0. to bar Ribbon cable option must be used for manifold assemblies that exceed 6 solenoids. (7th and 8th digit of valve order code) 70 - Fielbus Electronics Single pressure from a single supply Symbols RS RD RC RQ Relieving: exhausts pressure in cylinder if upstream pressure is exhausted Dual pressure from a single supply RE External outlet regulator used with jumper plate for single or dual pressure Non-relieving: taps downstream pressure if upstream is exhausted RT Two-pressure selector used for multi-pressure applications

Spare Parts Manifold Assembly Kits Z-Boards Z-Boards includes different Z-Boards for driving up to solenoids of single and double solenoid actuated valves. Ribbon cable feature must be used for manifold assemblies that exceed 6 solenoids. In order to allow the full capacity of solenoids, the assembly must be configured so that an even number of solenoids is utilised prior to the station using the ribbon cable feature. Note: The 6th and 7th solenoid cannot be on the same valve. (See valve model number selection for 7th and 8th digit for valve with 7th solenoid). Manifold Assemblies 8 7 6 Manifold assemblies BOrder Code Order Code Order Code Order Code Weight with side ports G / NPTF / G /8 NPTF /8 approx. with bottom ports G /8 NPTF /8 G /8 NPTF /8 [kg] With single Z-Board 06-60 06-608 06-6 06-609 0.60 With double Z-Board 06-6 06-6 06-6 06-6 0.6 With single Z-Board and ribbon cable 06-6 06-60 06-6 06-6 0.690 With double Z-Board and ribbon cable 06-68 06-66 06-69 06-67 0.69 Ribbon cable for Valve Station with 7th Solenoid Description Order Code Ribbon cable 0 9-6 Fielbus Electronics - 7

Spare Parts Mid-Station Supply & Exhaust Block Mid-Station Supply & Exhaust Block Add additional supply and exhaust capacity to large manifold assemblies Add different pressure to manifold section with use of blocking disks Same size as standard manifold block with blank station plate Supply Port Port Exhaust Description Weight Order approx. [kg] Code Mid-station supply & exhaust block 0.770 9- On request: Threaded ports in NPTF Spare Parts Conversion of Pilot Air Supply Conversion of Pilot Air Supply Manifolds can easily be converted from internal to external pilot supply. When converting from internal to external pilot supply, please ensure that the manifold is not pressurised, as pressure is applied to the end plate covers. For external pilot supply plug here. Left end plate only! For internal pilot supply plug here. Left end plate only! Plug for conversion of pilot supply -90 Архангельск (88)6-90-7 Астана (77)77- Астрахань (8)99-6-0 Барнаул (8)7-0-60 Белгород (7)0--6 Брянск (8)9-0- Владивосток ()9-8- Волгоград (8)78-0-8 Вологда (87)6--9 Воронеж (7)0--7 Екатеринбург ()8--89 Иваново (9)77--06 Ижевск ()6-0-8 Казань (8)06-0-8 Калининград (0)7-0-8 Калуга (8)9--67 Кемерово (8)6-0-6 Киров (8)68-0-0 Краснодар (86)0-0-90 Красноярск (9)0-6-6 Курск (7)77--0 Липецк (7)-0-8 Магнитогорск (9)-0- Москва (9)68-0-70 Мурманск (8)9-6-9 Набережные Челны (8)0-- Нижний Новгород (8)9-08- Новокузнецк (8)0-6-8 Новосибирск (8)7-86-7 Омск (8)-6-0 Орел (86)-- Оренбург ()7-68-0 Пенза (8)--6 Пермь ()0-8-7 Ростов-на-Дону (86)08-8- Рязань (9)6-6-6 Самара (86)06-0-6 Санкт-Петербург (8)09-6-0 Саратов (8)9-8-78 Севастополь (869)--9 Симферополь (6)67--6 Смоленск (8)9-- Сочи (86)-7- Ставрополь (86)0-6- Сургут (6)77-98- Тверь (8)6-- Томск (8)98-- Тула (87)7-0-9 Тюмень ()66--8 Ульяновск (8)--9 Уфа (7)9-8- Хабаровск ()9-98-0 Челябинск ()0-0-6 Череповец (80)9-0-6 Ярославль (8)69--9 сайт: http://asco.nt-rt.ru эл. почта: ach@nt-rt.ru