M Series External Battery Frame. User Guide

Similar documents
RT Series Battery Pack UL for RT 6 and 10 kva UPS UL. Extended Battery Pack. User Guide

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Galaxy VM. Battery Breaker Box Installation 09/

Galaxy VM. Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017.

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

Freedom egen System End-of- Line Functional Checklist

www. ElectricalPartManuals. com TOSHIBA 1600EP SERIES MANUFACTURED IN THE U.S.A. OPERATION MANUAL BATTERY CABINET SYSTEM SINGLE PHASE- 8/10/14/18 kva

Galaxy Receiving and Unpacking 09/

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Power Inverter 400 MW Owner s Manual

Galaxy VM. Modular Battery Cabinets Installation GVMMODBCW, GVMMODBCN 09/

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

Additional Battery Unit BUM100RE Instruction Manual

P90L-ISO6MB & ISO10MB

BRAVER UPS. (Uninterruptible Power System) User s Manual

USER MANUAL GEBRUIKSAANWIJZING. Phoenix 12/150 Phoenix 24/150 Phoenix 48/150

BR62 Battery Rack Installation, Operation, & Maintenance Manual

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

Galaxy Installation 08/

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

SDU 24-BATEM. Instruction Manual. Technical Services External Battery. U.S.A... (800) International (847)

Transformer Module for 6-10KVA User s Manual 6-10KVA-GTM

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

Grape Solar Photovoltaic Modules. User Manual

Galaxy kva 3:3 and 3:1. Receiving and Unpacking. 380/400/415 and 208/220 V 04/2016.

USER MANUAL English / Español

230VAC Power Inverter 400W Owner s Manual

Operating Instructions for PAC800 Battery Charger

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Pure Sine Wave Inverter 600W-24V User Manual

EnergyCell FLA Series. Owner s Manual

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

www. ElectricalPartManuals. com

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

USER MANUAL. Uninterruptible power supply MODEL: 53965,

CX-SERIES ADVANCED BATTERY CHARGER

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

APPLICATION NOTE. Conext Solar Charge Controllers: Ground Fault Protection. Document Number: AU-1.0. Exclusion for Documentation.

Go Power! Manual. GP-Smart Charger

Powerware Vdc Extended Battery Cabinet User s Guide.

APPLICATION NOTE: OPEN LOOP INTEGRATION WITH MAGNUM ENERGY

AGM Series. Installation Manual AGM Series Modular Battery Systems

AIS and 40 kva 400 V. Site Preparation and Installation Manual

UZK24.121, UZO GENERAL DESCRIPTION 2. DATA 4. MARKINGS 3. ORDER NUMBERS

Symmetra PX. 48 kw 400 V, 96 kw 400 V, 100 kw 208 V, 160 kw 400 V. Receiving and Unpacking 01/2016.

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

Installation, Operation & Maintenance Manual DataSafe HX Front Terminal Battery Cabinets

Operating Manual

1600XP/1600XPi SERIES 8-22kVA BATTERY CABINET INSTALLATION AND OPERATION MANUAL SINGLE PHASE 8/10/14/18/22 kva: 288Vdc

User Manual. Solar Charge Controller 3KW

Galaxy 300 Battery Breaker Kit G3HTBKIT1

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

General Precautions. Personnel Precautions

APPLICATION NOTE: CLOSED LOOP INTEGRATION WITH XANBUS ENABLED SCHNEIDER ELECTRIC CONEXT PRODUCTS

Grape Solar Photovoltaic Modules. User Manual

CTFRP Series Power Supplies

Installation and Operating Instructions. Solar System Controller ISC3020

GSL Electronics Modified Sine Wave Power Inverters

Battery Unit BHM60PC/BHM100PC Instruction Manual

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

SAVE THESE INSTRUCTIONS

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

HOYMILES MICRO-IVERTER MI-250

Air-Operated Waste Oil Drainer

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in

Installation And Operation Instructions

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

Smart-UPS VT kva 208/220 V Single and Parallel Installation. With Batteries 11/2016.

20W Polycrystalline Solar Panel

Power your day-to-day when others are power-less. Humless Sentinel User s Guide.

Powerware 9390 Integrated Battery Cabinet (Models IBC-S and IBC-L) Installation Manual

Operating Manual / / REV F

ADI-125/750 ADI-125/1500 ADI-125/2500

Assembly instructions

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Safety and General Information

30,000mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Extended Battery Cabinet for Nfinity

Cordless Rechargeable Saw Instructions for Use

INSTRUCTION MANUAL. CAT Place Table Top Centrifuge

Instruction Manual. Power Glide Limited Warranty Consumer Power Tools for Home Use. Model No:

EVS RP6020. Instruction Manual

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Battery Back-up BBM Owner's Manual. Please read this manual BEFORE installing your inverter

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

XLR Energy Storage Module

S9 SWEEPER PARTS MANUAL

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

6 Bay Battery Charger Operation Manual

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

SBC V In-Car Charger Dual Input (Solar MPPT & DC)

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

Transcription:

M Series External Battery Frame User Guide M 24-065-144 BF-NB M 24-100-144 BF-NB M 24-120-144 BF-NB UNLESS SPECIFICALLY AGREED TO IN WRITING, SELLER (A) MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION; (B) ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RISK; AND (C) REMINDS YOU THAT IF THIS MANUAL IS IN ANY LANGUAGE OTHER THAN ENGLISH, ALTHOUGH STEPS HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE TRANSLATION, THE ACCURACY CANNOT BE GUARANTEED. APPROVED CONTENT IS CONTAINED WITH THE ENGLISH LANGUAGE. (D) INFORMS YOU THE INFORMATION IN THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. (E) RESERVES ALL RIGHTS. KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 1)

Table of Contents Chapter 1. Important Safety Instructions... 3 1.1. Technical Notice... 4 Chapter 2. Overview... 5 Chapter 3. Selecting Installation Position... 5 Chapter 4. Installation of M 24-065-144 BF-NB... 6 4.1. Unpacking... 6 4.2. Installation Instructions... 7 4.3. M 24-065-144 BF-NB Inter-Battery Connection Guide... 11 Chapter 5. Installation of M 24-100-144 BF-NB and M 24-120-144 BF-NB... 12 5.1. Unpacking... 12 5.2. Installation Instructions... 12 5.3. M 24-100-144 BF-NB and M 24-120-144 BF-NB Inter-Battery Connection Guide... 17 5.4. Storage Instruction... 17 5.5. Specification... 18 KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 2)

Chapter 1. Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains important instructions that you should follow during installation and maintenance of the M Series External Battery Frame (MBF). Please read all instructions before operating the equipment and save this manual for future reference. Only qualified service personnel with knowledge of batteries and the required precautions should perform servicing. DANGER Batteries present a risk of electrical shock or burn from high short-circuit current. Batteries also pose a toxic danger due leakage of hazardous chemicals. To reduce the risks associated with exposure to toxic chemicals, electrical shocks and burns: Remove watches, rings, or other metal objects Use tools with insulated handles. Test for voltage before handling equipment. Wear protective glasses, gloves and boots. Do not lay tools or other metal parts on top of batteries. Keep unauthorized personnel away from batteries. Failure to follow these instructions will result in death or serious injury. DANGER Batteries may explode when exposed to open flame. To reduce the risk of explosion: Keep sparks and flames away from the batteries. Never dispose of batteries in a fire. Proper disposal of batteries is required. Refer to local codes for disposal requirements. Failure to follow these instructions will result in death or serious injury. DANGER To reduce the risk of fire or electric shock: Install or service the M Series Battery Frame in a temperature and humidity controlled, indoor environment, free of conductive contaminants. Ambient temperature must not exceed 40 C (104 F). Do not operate near water or excessive humidity (30-90% non-condensing). Overcurrent protection and disconnect switch must be provided by others. Install the M Series Battery Frame so that all wiring is inaccessible to users. Failure to follow these instructions may result in death or serious injury. Recycling of Used Batteries Contact your local recycling or hazardous waste center for information on proper disposal of the used battery. KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 3)

1.1. Technical Notice If the M Series Battery Frame (MBF) requires transportation, consult with the transport company and take the recommended precautions. Always disconnect batteries and isolate prior to transportation. If the MBF must be stored, protect it from excessive humidity and heat. Batteries should be mounted in an environment where the temperature is within the required specs. Temperature is a major factor in determining battery life and capacity. In a normal installation, the battery temperature is maintained between 15 C and 25 C, 30-90% noncondensing humidity. Keep batteries away from heat sources. Do not install the MBF and batteries in direct sunlight, battery lifetime may be reduced, and the battery warranty may be invalidated. Typical battery performance data are quoted for an operating temperature between 20 C and 25 C. Operating it above this range will reduce the battery life while operation below this range will reduce the battery capacity. An unused battery should be recharged every 6 months. Temporarily connect the MBF and batteries to the UPS with a suitable AC supply and activate it for the time required to recharge the batteries. When replacing batteries, only replace with the same type, capacity and quantity. Do not mix old and new batteries; do not mix different capacities or brands. The warranty for this battery cabinet will be void if water or other liquid is spilt or poured directly onto the battery cabinet. Similarly, we do not warrant any damage to the battery bank if foreign objects are deliberately or accidentally inserted into the battery cabinet enclosure. KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 4)

Chapter 2. Overview The MBF are designed for use with the M and C Series UPS. Dimensions are given below. The MBF is configured to output ±144V, supplied by 24 batteries in 2 sets connected in Series as BAT+, BATN, BAT. M 24-065-144 BF-NB M 24-100-144 BF-NB M 24-120-144 BF-NB W 600 * H 1600* D 850 mm W 600 * H 2000* D 850 mm W 600 * H 2000* D 850 mm Figure 1 Chapter 3. Selecting Installation Position It is necessary to select a proper indoors environment for the unit, in order to minimize the possibility of damage to the battery bank and extend the life of the batteries. 1. Keep at least 20cm (8 inches) clearance from the rear panel of the battery bank from the wall or other obstructions. 2. Do not block the airflow to the ventilation openings of the unit. 3. Please ensure the installation site environmental conditions are in accordance with the battery bank operating specifications to avoid overheating and exposure to excessive moisture. 4. Do not place the battery bank in a dusty or corrosive environment or near flammable material. 5. This battery frame is designed for indoor use only. KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 5)

Chapter 4. Installation of M 24-065-144 BF-NB The condition of the unit should be inspected carefully during the unpacking process. Retain the packing material for future use. WARNING The battery frame is heavy. To reduce the risk of personal injury: Be cautious when unpacking and lifting the battery frame. The battery frame is heavy and weights more than 50 kg. Failure to follow these instructions may result in serious injury. 4.1. Unpacking 1. Remove the battery cabinet from the packaging. 2. Remove the packing materials and save for later use. 3. Standard Package includes: M 24-065-144 BF-NB contains the following accessories: No. Name Specification Pcs. No. Name Specification Pcs. 1 Cable 1# 400mm(black) 8 5 Cable 5# 750mm(black) 1 2 Cable 2# 500mm(black) 4 6 60kVA Breaker ABS203b 3P 250A/250Vdc/415Vac 1 3 Cable 3# 1200mm (black) 1 7 100kVA Breaker ABS403b 3P 400A/415Vac 40KA/50KA 1 4 Cable 4# 650mm(black) 1 KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 6)

4.2. Installation Instructions The M 24-065-144 BF-NB is designed to hold 24 pieces of 65AH size batteries. DANGER Reversing the polarity of DC connections presents the risk of fire or electrical shock. To reduce the risk of fire or electric shock: Ensure the correct polarity of all DC connections. Do not allow metal to contact battery terminals or cable lugs. Do not touch battery terminals or cable lugs. Failure to follow these instructions may result in death or serious injury 1. Remove the side and rear wall panels, see Fig.2. Figure 2 2. Remove the 2 nd, 3 rd, 4 th, 5 th shelf plates. Install the batteries on the 1 st level (base) according to Fig.3 Connect and secure the inter-battery cables according to Fig.5. KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 7)

Figure 3 3. Install the 2 nd, 3 rd, 4 th and 5 th battery shelf plates in the cabinet as shown in Fig.4. Place the batteries on each shelf in the same configuration as the 1 st level. Complete the battery connections for all 5 layers according to Fig.5. Confirm all connections are tight and secure. Figure 4 KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 8)

4. After finishing the inter-battery connections, a cable from the BAT+ of the 5 th layer goes to the + breaker (BAT+), another cable from BAT+ of the 3 rd layer (13 th bat+) goes to the N breaker (BATN), the last cable from BAT- of the 1 st layer goes to the - breaker (BAT-) as shown in Fig.5. 5. When battery installation is completed, confirm that the wiring and battery voltage are both correct. Then re-install the side panels, back panel and top cover. 6. The battery cabinet should be grounded using cables with at least 50mm² diameter. KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 9)

Figure 5 KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 10)

4.3. M 24-065-144 BF-NB Inter-Battery Connection Guide Connect From Connect to 5# Battery 1 Pin 1 Battery breaker pin 3 BAT- 1# Battery 1 Pin 2 Battery 2 pin 2 Copper 1 Battery 2 Pin 3 Battery 3 pin 3 2# Battery 3 Pin 4 Battery 4 pin 4 1# Battery 4 Pin 5 Battery 5 pin 5 Copper 1 Battery 5 Pin 6 Battery 6 pin 6 2# Battery 6 Pin 7 Battery 7 pin 7 1# Battery 7 Pin 8 Battery 8 pin 8 Copper 1 Battery 8 Pin 9 Battery 9 pin 9 Copper 2 Battery 9 Pin 10 Battery 11 pin 10 Copper 1 Battery 10 Pin 11 Battery 11 pin 11 1# Battery 11 Pin 12 Battery 12 pin 12 2# Battery 12 Pin 13 Battery 13 pin 13 4# Battery 12 Pin 13 Battery breaker pin 2 BATN Copper 1 Battery 13 Pin 14 Battery 14 pin 14 1# Battery 14 Pin 15 Battery 15 pin 15 Copper 2 Battery 15 Pin 16 Battery 16 pin 16 1# Battery 16 Pin 17 Battery 17 pin 17 Copper 1 Battery 17 Pin 18 Battery 18 pin 18 2# Battery 18 Pin 19 Battery 19 pin 19 1# Battery 19 Pin 20 Battery 20 pin 20 Copper 1 Battery 20 Pin 21 Battery 21 pin 21 Copper 2 Battery 21 Pin 22 Battery 22 pin 22 Copper 1 Battery 22 Pin 23 Battery 23 pin 23 1# Battery 23 Pin 24 Battery 24 pin 24 3# Battery 24 Pin 25 Battery breaker pin 1 BAT+ KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 11)

Chapter 5. Installation of M 24-100-144 BF-NB and M 24-120-144 BF-NB The condition of the unit should be inspected carefully during the unpacking process. Retain the packing material for future use. WARNING The battery frame is heavy. To reduce the risk of personal injury: Be cautious when unpacking and lifting the battery frame. The battery frame is heavy and weights more than 50 kg. Failure to follow these instructions may result in serious injury. 5.1. Unpacking 4. Remove the battery cabinet from the packaging. 5. Remove the packing materials and save for later use. 6. Standard Package includes: M 24-100-144 BF-NB and M 24-120-144 BF-NB contain the following accessories: No. Name Specification Pcs. No. Name Specification Pcs. 1 Cable 1# 350mm(black) 16 6 Cable 6# 900mm(black) 1 2 Cable 2# 640mm(black) 2 7 Cable 7# 1400mm(black) 1 3 Cable 3# 580mm(black) 1 8 Cable 8# 650mm(black) 1 4 Cable 4# 700mm(black) 1 9 Breaker ABS603b 3P 600A/250Vdc/415Vac 40KA/50KA LS 5 Cable 5# 870mm(black) 1 1 5.2. Installation Instructions The M 24-100-144 BF-NB and M 24-120-144 BF-NB are designed to hold 24 pieces of 100AH or 120 AH size batteries. KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 12)

DANGER Reversing the polarity of DC connections presents the risk of fire or electrical shock. To reduce the risk of fire or electric shock: Ensure the correct polarity of all DC connections. Do not allow metal to contact battery terminals or cable lugs. Do not touch battery terminals or cable lugs. Failure to follow these instructions may result in death or serious injury 7. Remove the side and rear wall panels, see Fig.2. Figure 6 8. Remove the 2 nd, 3 rd, 4 th, 5 th shelf plates. Install the batteries on the 1 st level (base) according to Fig.3 Connect and secure the inter-battery cables according to Fig.5. KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 13)

Figure 7 9. Install the 2 nd, 3 rd, 4 th and 5 th battery shelf plates in the cabinet as shown in Fig.4. Place the batteries on each shelf in the same configuration as the 1 st level. Complete the battery connections for all 5 layers according to Fig.5. Confirm all connections are tight and secure. Figure 8 KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 14)

10. After finishing the inter-battery connections, a cable from the BAT+ of the 5 th layer goes to the + breaker (BAT+), another cable from BAT+ of the 3 rd layer (13 th bat+) goes to the N breaker (BATN), the last cable from BAT- of the 1 st layer goes to the - breaker (BAT-) as shown in Fig.5. 11. When battery installation is completed, confirm that the wiring and battery voltage are both correct. Then re-install the side panels, back panel and top cover. 12. The battery cabinet should be grounded using cables with at least 50mm² diameter. KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 15)

Figure 9 KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 16)

5.3. M 24-100-144 BF-NB and M 24-120-144 BF-NB Inter-Battery Connection Guide Connect From Connect to 8# Battery 1 Pin 1 Battery breaker pin 3 BAT- 1# Battery 1 Pin 2 Battery 2 pin 2 1# Battery 2 Pin 3 Battery 3 pin 3 2# Battery 3 Pin 4 Battery 4 pin 4 1# Battery 4 Pin 5 Battery 5 pin 5 1# Battery 5 Pin 6 Battery 6 pin 6 3# Battery 6 Pin 7 Battery 7 pin 7 1# Battery 7 Pin 8 Battery 8 pin 8 1# Battery 8 Pin 9 Battery 9 pin 9 4# Battery 9 Pin 10 Battery 11 pin 10 1# Battery 10 Pin 11 Battery 11 pin 11 1# Battery 11 Pin 12 Battery 12 pin 12 5# Battery 12 Pin 13 Battery 13 pin 13 6# Battery 12 pin 13 Battery breaker pin 2 BATN 1# Battery 13 Pin 14 Battery 14 pin 14 1# Battery 14 Pin 15 Battery 15 pin 15 Copper Battery 15 Pin 16 Battery 16 pin 16 1# Battery 16 Pin 17 Battery 17 pin 17 1# Battery 17 Pin 18 Battery 18 pin 18 2# Battery 18 Pin 19 Battery 19 pin 19 1# Battery 19 Pin 20 Battery 20 pin 20 1# Battery 20 Pin 21 Battery 21 pin 21 Copper Battery 21 Pin 22 Battery 22 pin 22 1# Battery 22 Pin 23 Battery 23 pin 23 1# Battery 23 Pin 24 Battery 24 pin 24 7# Battery 24 Pin 25 Battery breaker pin 1 BAT+ 5.4. Storage Instruction For extended periods of storage, ensure batteries are kept in a moderate climate (-15 to +30 C / +5 to +86 F). The batteries should be charged every 6 months by plugging into the UPS. If stored under high temperature (+30 to +45 C / +86 to +113 F) environment, repeat every three months. KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 17)

5.5. Specification Model M 24-065-144 BF-NB M 24-100-144 BF-NB M 24-120-144 BF-NB 12V Battery 65AH 100AH 120AH Nominal DC Voltage +/- 144 VDC +/- 144 VDC +/- 144 VDC Internal Configuration 24 pcs 24 pcs 24 pcs Breaker Net Weight kg (w/o battery) (1x) ABS203b 3P 250A/250Vdc/415Vac (1x) ABS403b 3P 400A/415Vac 40KA/50KA (1x) ABS603b 3P 600A/250Vdc/415Vac 40KA/50KA LS 197 197 197 (1x) ABS603b 3P 600A/250Vdc/415Vac 40KA/50KA LS H x W x L mm 1600 x 600 x 850 2000 x 600 x 850 2000 x 600 x 850 KE 4256-0482 M Series External Battery Frame Users Guide English 20181121 (page 18)