Cross-Flow Fans. TF/FF Series

Similar documents
Cross-flow Fans. TFD/FFD Series

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

Energy-saving motors (ESM)

Immersion Pumps PRG sealless

TYPE 2 poles 4 poles 6 poles 8 poles 2 / 4 poles 4 / 8 poles 2 / 8 poles 4 / 16 poles

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

MAX FLUID TEMPERATURE

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

AC axial fans S series, Ø 500

SOLENOID VALVES 1. GENERAL PURPOSE VALVES ACCESSORIES ORDER CODIFICATION : TEC22 DIRECT ACTING INDIRECT ACTING

CPLS Asynchronous motors for variable frequency. 95 Nm to 2900 Nm

AXIAL FAN WITH EXTERNAL ROTOR MOTOR

ELECTRIC VIBRATORS SPV & SPC

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

Standard and value-added costech frame fans with a comprehensive range of accessories

Differential Pressure Switch QBM81-

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

PPT 802, Proximity Probe Transducer System

Differential Pressure Switch QBM81-

PSC Thermal Solutions. size 273 x 220 x202mm

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

TOP MULTI. Submersible multi-stage pumps TOP MULTI 1 TOP MULTI 2-3. PERFORMANCE RANGE Flow rate up to 120 l/min (7.2 m³/h) Head up to 42 m

Thermal Overcurrent Circuit Breaker 3120-F...

ETM motors Data Book 50Hz - 60Hz

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

TG6 series cross flow fan units

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

LARGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS FOR HEAVY DUTY APPLICATIONS ADH SERIES

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

Immersion Pumps PS and PSL ( Slurp Pump ) sealless

Thermal-Magnetic Circuit Breaker M1-...

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

SPG-400. Solar-powered generators

Electric Immersion Pumps PRT and PRA, sealless

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

AC centrifugal module - RadiCal

Standard and value-added costech frame fans with a comprehensive range of accessories

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Differential pressure switch for monitoring air pressure in HVAC systems.

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315

ILA1F572PB1F0 integrated drive ILA with servo motor V - CANopen - PCB connector

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

CR A-F-A-V-HBQV 3x400/ HZ

AC centrifugal fan. backward curved

CRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz

Grundfos Home Booster

ILE1B661PC1A1 brushless dc motor V - Profibus DP interface - L = 174 mm - 18:1

Design features of models K and AC brakes. K DC-Powered Brake. AC Three phase Powered Brake

Thermal Overcurrent Circuit Breaker 3120-F...

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

Design specifications

Differential Pressure Sensors

FCR asynchronous brake motors LS FCR. General information

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

ILE2T661PB1A3 brushless dc motor V - Modbus TCP interface - L = 174 mm - 54:1

AC centrifugal fan. forward curved, dual inlet with housing (flange)

NK /310A2F1AE-SBAQE

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

TF037C MICRO BLOWERS FEATURES STANDARD SPECIFICATIONS

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

CR15-14 A-F-A-E-HQQE 3x400/ HZ

Transformer Oil Cooling Solutions

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

AXIAL FANS Catalogue CN0050C01 May 2008

BSW , -493, -494 Mechanical Rotary Cam Switches. User's Guide. Mechanical Rotary Cam Switches BSW BSW BSW

VALIADIS S.A. HELLENIC MOTORS

WINDER. Impellers with higher efficiency and less sound level

ELK PRODUCT CATALOGUE. elkmotor.com.tr

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

SKA DDR SKA DDR SKA DDR SKA DDR SKA DDR SKA DDR SKA DDR

RockStar HighPower. Contents. RockStar HighPower Introduction C.2 C.1

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

Exhaust Fans CATALOGUE 2013 / 14

AC centrifugal fan. forward-curved, dual-intake with housing (without flange)

- SPECIFICATIONS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART MULTIGO PERFORMANCE CHART MULTIGO

NK40-160/172A1F2AE-SBAQE

Motor-drive mechanism, type BUL. Technical guide

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

Miniaturized limit switches

HIGH-POWERED VENTILATORS

Cubic unit cooler. SKB semi-industrial range

SCHMITT. product information. Kreiselpumpen. U Pump Series. normal priming, centrifugal pumps with a single mechanical seal.

Powerful centrifugal fans for universal use: The product ranges TEM and REM

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

Transcription:

Cross-Flow Fans TF/FF Series Cross flow fans are particularly indicated for uses where, in limited space, high air volume is required with low noise and regular air-flow. The FF-FFD series provides an additional fixing option through 4 +4 extensions placed directly on the side. The information in this catalogue is provided for illustrative purposes only and it does not imply any contractual obligation. Coprel can make changes to this information at any time without any notice. Issue 1/12

Technical specifications: single phase, 2-shaded poles, impedance protected motor, built according to the CE mark requirements, in compliance with EN 335-1 standard, with selfaligning and self lubricating sleeve bearings with big oil reservoir; motor with minimum 1 B insulation class; suitable for continuous operation in ambient temperature from -1 C to + C; electrical connection by 6,3x,8 mm, radial or axial, male faston-type connectors, directly fixed on coil; constant thickness Ø mm aluminium impeller with forward curved blades fitted with intermediate reinforcement discs; housing made of pre-galvanized metal sheet, designed to ensure high aeraulic efficiency and low noise level. On request: version with IMQ - CSV approved motor; motor with different powers and insulation classes: 155 F - 18 H ; supply voltage from 12V to V /Hz; version with dual voltage and/or double rotation speed; electrical connection by means of different cable lengths; motor coil winding with IP55 protection; protection against dust and/or humidity; thermal protector and/or thermal fuse; housing with black cataphoresis coating; several HT versions for operation from - C to 1 C; built in compliance with UL-CSA standards; version fitted with ball bearings; version built to customers design. OUR TECHNICAL AND COMMERCIAL OFFICE CAN ADVISE YOU ON THE VERSION THAT MOST SUITS YOUR APPLICATION NEEDS Motor position -radial faston-type connectors (table 1) Product Identification Code T F R 2 T 1 A SN HT BB VR 2 1 2 3 4 5 6 7 8 9 1 11 12 13 1) TF series: standard housing FF series: housing with ears see FF series dimensions 2) motor position R: motor on the right of the air outlet L: motor on the left of the air outlet TFL/FFL TFR/FFR 3) fan blade nominal length 9-1 - 18-2 - 27 - - 3-4 - 48 mm 4) motor stack height 15---35- mm 5) thermal protection T: thermal protector F: thermal fuse blank: impedance protected 6) coil winding code 7) electrical connection R: radial faston-type connectors A: axial faston-type connectors C: cables 8) motor position see table 1 and 2 below 9) on request (*) HT: high-temperature version IV-IM-PRN: low temperature with high relative humidity up to 92% INC: coil insulation with IP55 protection 1) on request BB: ball bearings on motor BBBLV: ball bearings on motor and impeller 11) on request, fitted with cooling fan on motor side 12) supply voltage 13) rated frequency (*) Impregnated versions: IV version: impregnated coil through dip-coating using epoxy transparent paint. (standard stator coil dip-coating process). PRN version: coil coated with black epoxy resin, the coil is protected by a clearly visible layer of resin. IM version: impregnated coil through dip-coating using transparent epoxy paint with silicone applied on contacts at the end of winding, three-pole wire and coil covered by a nylon cap. The coil is not buried in the resin but visible; caution should be paid when mounting the motor so that the cap open part faces downward to prevent its filling up with condensate. INC version: coil with IP55 protection, the coil is completely buried into the epoxy resin. Motor position -axial faston-type connectors (table 2)

TF dimensions The dimensions are in millimeters. TF versions Series Motor Dimensions A B C D H I Power (W) Current (A) RPM Flow rate (m 3 /h) Static pressure ( Pa) TF 9/15 15-1 156 64 94 14 15 53,5 16,13 22 8 53 1 TF 9/ -1 162 64 94 14 58,5,15 25 92 59 2 TF 1/15 15-1 186 94 124 134 15 53,5 18,14 18 11 49 3 TF 1/ -1 191 94 124 134 58,5 22,16 22 127 4 TF 18/15 15-1 246 154 184 194 15 53,5 19,15 12 17 48 5 TF 18/ -1 251 154 184 194 58,5 23,17 17 144 62 6 TF 18/ -1 261 154 184 194 68,5 35,25 24 212 73 7 TF 18/35 35-1 266 154 184 194 35 73,5 41,31 25 234 75 8 TF 2/ -1 311 214 244 254 58,5 24,18 1 149 55 9 TF 2/ -1 321 214 244 254 68,5 37,27 2 262 78 1 TF 2/35 35-1 326 214 244 254 35 73,5 45,33 23 283 8 11 TF 27/ -1 341 244 274 284 58,5 24,18 11 163 42 12 TF 27/ -1 351 244 274 284 68,5 39,28 19 28 78 13 TF 27/35 35-1 356 244 274 284 35 73,5 46,34 21 313 8 14 TF / -1 371 274 4 314 58,5 24,18 11 171 45 15 TF / -1 381 274 4 314 68,5,29 17 268 77 16 TF / -1 391 274 4 314 78,5 48,37 348 8 17 TF 3/ -1 431 334 364 374 58,5 24,18 9 183 18 TF 3/ -1 441 334 364 374 68,5,3 13 262 78 19 TF 3/ -1 451 334 364 374 78,5 53,4 19 325 78 TF 4/ -1 1 394 424 434 68,5 41,31 1 271 7 21 TF 4/ -1 511 394 424 434 78,5 54,42 1 359 76 22 TF 48/ -1 561 454 484 494 68,5,3 11 283 62 23 TF 48/ -1 571 454 484 494 78,5 54,42 12 364 69 24 Curve n

FF dimensions The dimensions are in millimeters. FF versions Series Motor Dimensions A B C E F H I Power (W) Current (A) RPM Flow rate (m 3 /h) Static pressure ( Pa) FF 9/15 15-1 156 64 94 13 112 15 53,5 16,13 22 8 53 1 FF 9/ -1 162 64 94 13 112 58,5,15 25 92 59 2 FF 1/15 15-1 186 94 124 133 142 15 53,5 18,14 18 11 49 3 FF 1/ -1 191 94 124 133 142 58,5 22,16 22 127 4 FF 18/15 15-1 246 154 184 193 2 15 53,5 19,15 12 17 48 5 FF 18/ -1 251 154 184 193 2 58,5 23,17 17 144 62 6 FF 18/ -1 261 154 184 193 2 68,5 35,25 24 212 73 7 FF 18/35 35-1 266 154 184 193 2 35 73,5 41,31 25 234 75 8 FF 2/ -1 311 214 244 253 262 58,5 24,18 1 149 55 9 FF 2/ -1 321 214 244 253 262 68,5 37,27 2 262 78 1 FF 2/35 35-1 326 214 244 253 262 35 73,5 45,33 23 283 8 11 FF 27/ -1 341 244 274 283 292 58,5 24,18 11 163 42 12 FF 27/ -1 351 244 274 283 292 68,5 39,28 19 28 78 13 FF 27/35 35-1 356 244 274 283 292 35 73,5 46,34 21 313 8 14 FF / -1 371 274 4 313 322 58,5 24,18 11 171 45 15 FF / -1 381 274 4 313 322 68,5,29 17 268 77 16 FF / -1 391 274 4 313 322 78,5 48,37 348 8 17 FF 3/ -1 431 334 364 373 382 58,5 24,18 9 183 18 FF 3/ -1 441 334 364 373 382 68,5,3 13 262 78 19 FF 3/ -1 451 334 364 373 382 78,5 53,4 19 325 78 FF 4/ -1 1 394 424 433 442 68,5 41,31 1 271 7 21 FF 4/ -1 511 394 424 433 442 78,5 54,42 1 359 76 22 FF 48/ -1 561 454 484 493 2 68,5,3 11 283 62 23 FF 48/ -1 571 454 484 493 2 78,5 54,42 12 364 69 24 Curve n

Typical curves TF/FF 1 TF/FF 9 2 1 9 7 8 1 7 8 7 5 6 9 11 1 1 1 1 TF/FF 27 1 TF/FF 8 8 7 7 14 TF/FF 2 8 13 12 17 16 15 1 1 3 1 TF/FF 18 4 1 1 1 1 8 7 7 TF/FF 4 8 19 18 1 7 21 1 TF/FF 48 24 23 1 22 1 1 1