Cross-flow Fans. TFD/FFD Series

Similar documents
Cross-Flow Fans. TF/FF Series

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

Energy-saving motors (ESM)

Immersion Pumps PRG sealless

TYPE 2 poles 4 poles 6 poles 8 poles 2 / 4 poles 4 / 8 poles 2 / 8 poles 4 / 16 poles

AXIAL FAN WITH EXTERNAL ROTOR MOTOR

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

MAX FLUID TEMPERATURE

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

SOLENOID VALVES 1. GENERAL PURPOSE VALVES ACCESSORIES ORDER CODIFICATION : TEC22 DIRECT ACTING INDIRECT ACTING

CPLS Asynchronous motors for variable frequency. 95 Nm to 2900 Nm

AC axial fans S series, Ø 500

ELECTRIC VIBRATORS SPV & SPC

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

Standard and value-added costech frame fans with a comprehensive range of accessories

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Differential Pressure Switch QBM81-

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

PSC Thermal Solutions. size 273 x 220 x202mm

A6C A5C-B6C B5C B5H A6C A5C B6C B5C B5H. Model. Up to kw. Power. Up to V. Voltages. Model IP55. Frame Pole 2, 4, 6, 8 and 10

PPT 802, Proximity Probe Transducer System

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

TOP MULTI. Submersible multi-stage pumps TOP MULTI 1 TOP MULTI 2-3. PERFORMANCE RANGE Flow rate up to 120 l/min (7.2 m³/h) Head up to 42 m

ETM motors Data Book 50Hz - 60Hz

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

TG6 series cross flow fan units

Thermal Overcurrent Circuit Breaker 3120-F...

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

LARGE THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS FOR HEAVY DUTY APPLICATIONS ADH SERIES

Immersion Pumps PS and PSL ( Slurp Pump ) sealless

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

Electric Immersion Pumps PRT and PRA, sealless

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Standard and value-added costech frame fans with a comprehensive range of accessories

AC centrifugal module - RadiCal

Thermal-Magnetic Circuit Breaker M1-...

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

SPG-400. Solar-powered generators

High Performance Thermal Circuit Breaker

Differential pressure switch for monitoring air pressure in HVAC systems.

Differential Pressure Switch QBM81-

ILA1F572PB1F0 integrated drive ILA with servo motor V - CANopen - PCB connector

AC centrifugal fan. backward curved

ILE1B661PC1A1 brushless dc motor V - Profibus DP interface - L = 174 mm - 18:1

Design features of models K and AC brakes. K DC-Powered Brake. AC Three phase Powered Brake

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

Design specifications

CR A-F-A-V-HBQV 3x400/ HZ

CRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz

Thermal Overcurrent Circuit Breaker 3120-F...

Solenoid coils VACF Type codes

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

ILE2T661PB1A3 brushless dc motor V - Modbus TCP interface - L = 174 mm - 54:1

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

AC centrifugal fan. forward curved, dual inlet with housing (flange)

FCR asynchronous brake motors LS FCR. General information

NK /310A2F1AE-SBAQE

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

Thermal-Magnetic Circuit Breaker M1-..

CR15-14 A-F-A-E-HQQE 3x400/ HZ

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

AXIAL FANS Catalogue CN0050C01 May 2008

BSW , -493, -494 Mechanical Rotary Cam Switches. User's Guide. Mechanical Rotary Cam Switches BSW BSW BSW

VALIADIS S.A. HELLENIC MOTORS

WINDER. Impellers with higher efficiency and less sound level

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

SKA DDR SKA DDR SKA DDR SKA DDR SKA DDR SKA DDR SKA DDR

ELK PRODUCT CATALOGUE. elkmotor.com.tr

RockStar HighPower. Contents. RockStar HighPower Introduction C.2 C.1

Exhaust Fans CATALOGUE 2013 / 14

CONTINUO. Radial centrifugal impeller. Radial centrifugal impellers dynamically balanced, according to ISO 1940 standard,

AC centrifugal fan. forward-curved, dual-intake with housing (without flange)

- SPECIFICATIONS SPECIFICATIONS 200 SELECTION CHART 201 PERFORMANCE CHART MULTIGO PERFORMANCE CHART MULTIGO

Motor-drive mechanism, type BUL. Technical guide

NK40-160/172A1F2AE-SBAQE

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

Miniaturized limit switches

Cubic unit cooler. SKB semi-industrial range

HIGH-POWERED VENTILATORS

SCHMITT. product information. Kreiselpumpen. U Pump Series. normal priming, centrifugal pumps with a single mechanical seal.

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

AC axial fan. sickled blades (S series), single inlet Wall ring with guard grille

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

CGA CXA VGA VXA CG-PRC006-E4

Differential Pressure Sensors

Transcription:

Cross-flow Fans TFD/FFD Series Cross flow fans are particularly indicated for uses where, in limited space, high air volume is required with low noise and regular air-flow. The FF-FFD series provides an additional fixing option through 4 +4 extensions placed directly on the side. The information in this catalogue is provided for illustrative purposes only and it does not imply any contractual obligation. Coprel can make changes to this information at any time without any notice. Issue 1/12

Technical specifications: single phase, 2-shaded poles, impedance protected motor, built according to the CE mark requirements, in compliance with EN 335-1 standard, with selfaligning and self lubricating sleeve bearings with big oil reservoir; motor with minimum 1 B insulation class; suitable for continuous operation in ambient temperature from - C to + C; electrical connection by 6,3x,8 mm, radial or axial, male faston-type connectors, directly fixed on coil; constant thickness Ø mm aluminium impeller with forward curved blades fitted with intermediate reinforcement discs; housing made of pre-galvanized metal sheet, designed to ensure high aeraulic efficiency and low noise level. On request: version with IMQ - CSV approved motor; motor with different powers and insulation classes: 155 F - 18 H ; supply voltage from 12V to V /Hz; version with dual voltage and/or double rotation speed; electrical connection by means of different cable lengths; motor coil winding with IP55 protection; protection against dust and/or humidity; thermal protector and/or thermal fuse; housing with black cataphoresis coating; several HT versions for operation from - C to C; built in compliance with UL-CSA standards; version fitted with ball bearings; version built to customers design. OUR TECHNICAL AND COMMERCIAL OFFICE CAN ADVISE YOU ON THE VERSION THAT MOST SUITS YOUR APPLICATION NEEDS Product Identification Code T FD 18 35 T 1 R FN HT BBBLV 2 1 2 3 4 5 6 1) TFD series: standard housing FFD series: housing with ears see FFD series dimensions 2) fan blade nominal length 9-1 - 18-2 - 2 - - 3 mm 3) motor stack height 15 - - - 35 - mm 4) thermal protection T: thermal protector F: thermal fuse blank: impedance protected 5) coil winding code 6) electrical connection R: radial faston-type connectors A: axial faston-type connectors C: cables 7) motor position see table 1 and 2 below 8) on request (*) HT: high-temperature version IV-IM-PRN: low temperature with high humidity up to 92% INC: coil insulation with IP55 protection 9) on request BB: ball bearings on motor BBBLV: ball bearings on motor and impeller ) supply voltage 11) rated frequency (*) Impregnated versions: IV version: impregnated coil through dip-coating using epoxy transparent paint. (standard stator coil dip-coating process). PRN version: coil coated with black epoxy resin, the coil is protected by a clearly visible layer of resin. IM version: impregnated coil through dip-coating using transparent epoxy paint with silicone applied on contacts at the end of winding, three-pole wire and coil covered by a nylon cap. The coil is not buried in the resin but visible; caution should be paid when mounting the motor so that the cap open part faces downward to prevent its filling up with condensate. INC version: coil with IP55 protection, the coil is completely buried into the epoxy resin. 7 8 9 11 Motor position -radial faston-type connectors (table 1) Motor position -axial faston-type connectors (table 2)

TFD dimensions The dimensions are in millimeters. TFD versions Series Motor Dimensions A B C D H I Power (W) Current (A) RPM Flow rate (m 3 /h) Static Curve pressure n ( Pa) TFD 18/ -1 445 154 184 194 61 23,18 99 168 38 1 TFD 18/ -1 455 154 184 194 71 38,29 1645 28 63 2 TFD 18/35 35-1 4 154 184 194 35 76 47,35 188 331 69 3 TFD 2/ -1 565 214 244 254 71 38,29 11 283 62 4 TFD 2/35 35-1 5 214 244 254 35 76 49,37 13 3 65 5 TFD 2/ -1 575 214 244 254 81 55,43 14 335 69 6 TFD 2/ -1 625 244 274 284 71 39,29 9 7 58 7 TFD 2/ -1 365 244 274 284 81 52,42 12 343 65 8 TFD / -1 385 274 4 314 71 39,29 333 51 9 TFD / -1 695 274 4 314 81 52,41 11 347 67 TFD 3/ -1 85 334 364 374 71 39,3 9 359 44 11 TFD 3/ -1 815 334 364 374 81 52,42 382 65 12

FFD dimensions The dimensions are in millimeters. FFD versions Series Motor Dimensions A B C E F H I Power (W) Current (A) RPM Flow rate (m 3 /h) Static Curve pressure n ( Pa) FFD 18/ -1 445 154 184 193 2 61 23,18 99 168 38 1 FFD 18/ -1 455 154 184 193 2 71 38,29 1645 28 63 2 FFD 18/35 35-1 4 154 184 193 2 35 76 47,35 188 331 69 3 FFD 2/ -1 565 214 244 253 262 71 38,29 11 283 62 4 FFD 2/35 35-1 5 214 244 253 262 35 76 49,37 13 3 65 5 FFD 2/ -1 575 214 244 253 262 81 55,43 14 335 69 6 FFD 2/ -1 625 244 274 283 292 71 39,29 9 7 58 7 FFD 2/ -1 365 244 274 283 292 81 52,42 12 343 65 8 FFD / -1 385 274 4 313 322 71 39,29 333 51 9 FFD / -1 695 274 4 314 322 81 52,41 11 347 67 FFD 3/ -1 85 334 364 373 382 71 39,3 9 359 44 11 FFD 3/ -1 815 334 364 373 382 81 52,42 382 65 12

Typical curves TFD/FFD 18 TFD/FFD 2 8 1 1 2 3 1 2 3 7 2 8 3 TFD/FFD 2 8 1 2 3 TFD/FFD 1 2 3 4 9 5 6 TFD/FFD 3 11 12 1 2 3