www. ElectricalPartManuals. com MECHANICAL RELIEF DEVICE

Similar documents
www. ElectricalPartManuals. com Instructions for Cast Resin Bushing, 15 KV & Below

www. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE

www. ElectricalPartManuals. com INSTRUCTIONS DynAC Broke DESCRIPTION ADJUSTMENT MAINTENANCE The Alternating Current Dynamic Brake

Model ES-660-HF High Flow Spring-Loaded Hatch

www. ElectricalPartManuals. com INSTRUCTIONS INTERLOCKED MOTOR-DRIVEN OPERATING MECHANISM For No-Load Tap Changers DESCRIPTION OPERATION MAINTENANCE

SERIES WC & WCS. Watchman Series & WCS Condensate Units. Replacement Parts for. Hoffman PARTS LIST DN0436. Hoffman Pump

Type 644 and 645 Differential Pressure Pump Governors

Operating & Maintenance Manual For Steam Conditioning Valve

EISHO TEK. Vacuum Circuit Breaker

Types 472, 473, 3572, 3573

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Instructions for Replacing

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

www. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Swing-Flex Check Valve

Fuel Gas/ Starting Air Valve Series

MICRO WELD MODEL AUF-8 HEAVY DUTY FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL

Features. North & South America: Europe / Africa / Middle East: Asia Pacific:

Installation Instructions

ATMOSPHERIC RELIEF VALVE

Installation, Operation and Maintenance Manual. TOM WHEATLEY Piston Check Valve TOM WHEATLEY

Installation & Parts Manual V-15, V-30, VS-3, and VS-4 Valves

Scraper Passage Indicator Bulletin No: Version: Supersedes: ( ) ECN: E Features

750 Series Press Conveyor Installation and Maintenance Manual

TS-E TURBO STEAM ELECTRIC COUNTERTOP CONVECTION STEAMER PARTS AND SERVICE MANUAL

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

Fisher 1052 Size 70 Diaphragm Rotary Actuator

Pressure Sensor No Series

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

INSTRUCTION MANUAL AND PARTS LIST FOR 3E CANNED MOTOR PUMPS

INSTALLATION - MAINTENANCE MANUAL Severe Service Series M4 Ball Valve

USER INSTRUCTIONS. Kämmer SmallFlow - Series / Low and Micro Flow Valves. Installation Operation Maintenance. Experience In Motion

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

The Solution For The Valve Problems Plug Valves

OPERATING AND MAINTENANCE MANUAL

Transmission Overhaul Procedures-Bench Service

Swing-Flex Check Valve

Mounting and Operating Instructions EB EN. Type 3271 and Type 3277 Pneumatic Actuators. Actuator areas: 175v2, 350v2, and 750v2 cm²

Crispin Valves Operating Guide. Crispin

Type 63EG-98HM Pilot-Operated Relief Valve or Backpressure Regulator

Installation Instructions Capacity 10,000 lbs. (100 Series Lift)

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

Westingh'ouse Steam Turbines-I. B (Rev. 3) GOVERNOR, GOVERNING VALVE

450 Series Belt Driven Live Roller Curve Conveyor Installation and Maintenance Manual

Pressure Relief Valve Maintenance Manual

ichards MANUFACTURING COMPANY, SALES, INC. 517 LYONS AVENUE, IRVINGTON, NJ Phone Fax

Fisher RSS Lined Globe Valve

CONTROL VALVES. KOSO HAMMEL DAHL tel: Manley Street fax: Installation, Maintenance & Operating Instructions

Val-Matic 3-Way Tapered Plug Valve

Series Single seated top guided control valve. Preventive maintenance. Overhauling procedure. Wörth am Main SERVICE NOTE. Control Valve Division

BR 31a Rack-and-pinion Actuator,

Series Roll Seal

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

Installation, Operation and Maintenance Manual for Pressure/Vacuum Relief Valves (Spring Loaded)

KOSO HAMMEL DAHL CONTROL VALVES. Installation, Maintenance & Operating Instructions

B CW POWER RELAY

AUTOMATION ACCESSORIES IN-PLANT VALVE PRODUCTS EXTENSION STEMS FLOORBOX STEM GUIDES FLOORSTANDS COMMITTED TO ENVIRONMENTAL RESPONSIBILITY FLAP VALVES

OPERATION AND MAINTENANCE MANUAL

2006 Series Geared Rotary Limit Switches

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

Type 3571 Pneumatic Actuator. Actuator areas: 27 in² 54 in² 116 in². Original instructions. Mounting and Operating Instructions EB 8820 EN

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

Instructions for Installation, Operation, Care and Maintenance

MICRO WELD MODEL DP1 & DP2 HEAVY DUTY NON-FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL

4.2 WATER PUMP (GEAR CASE MOUNTED AND LATER) (GCM)

Fisher L2e Electric Level Controller

INSTALLATION GUIDE STANDARD PRODUCT CODES:

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers

Installation, Operating & Maintenance Instructions

Installation Manual For ISL98, ISL03, ISL07, ISC07

627 Series Pressure Reducing Regulators

SERVICE MANUAL (INTERNATIONAL)

627 Series Pressure Reducing Regulators

Globe Control Valve Series 1a

DeZURIK DR 125 ROTARY DIAPHRAGM ACTUATOR

2506 Series Multi-Trol Receiver/Controllers (Types 2506, 2516, 2516F)

Anderson Greenwood Single Active SSV Installation and Maintenance Instructions

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#:

Serie 2003/2013. Three-way Control Valve, mixing/diverting. Wörth am Main. Service. Control Valve Division

Fisher 657 Diaphragm Actuator Sizes and 87

Maintenance and Service Instruction

Baumann Pneumatic Actuators

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

MICRO WELD MODEL AD 3-5 HEAVY DUTY NON-FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL

Introduction. Installation. I & M Mark V-100 Series. Installation & Maintenance Instructions for the Mark V-100 Series Control Valves

Series 1b Control Valve

DVG/AF Variable Geometry Desuperheater

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

ST-E STEAM IT COUNTERTOP ELECTRIC PRESSURE COOKER PARTS AND SERVICE MANUAL

CONTROL VALVES SINGLE PORTED CLASSES DL, DDL, DOS, DDOS

A39 UNIVERSAL SCR CHARGER

INSTRUCTIONS For Field Assembly and Installation

Instructions for Installation, Operation Care and Maintenance

1004D2/1005E API Bottom Loading Coupler. 1005E Small handles used throughout Europe 1004D

Adjustable Differential Relay A1

INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00

Adjustable Dead Band Pressure Switches


Transcription:

MECHANICAL RELIEF DEVICE FIG. 1. Cutaway View of Device. THE MECHANICAL RELIEF DEVICE, mounted on the transformer cover, is designed to relieve any dangerous pressures which may build up within the transformer tank. When a predetermined pressure is exceeded, a tripping mechanism unlocks the relief cover, allowing it to rise and vent the tank. It is always possible, although fortunately very unusual, that some fault under the oil level may result in a primary explosion. While the wavefront of pressure created in this way is not as steep as that of a secondary explosion of hydrogen or acetylene and air above the oil, nor the results as violent, the abnormal pressure following an arc is often great enough to rupture the tank if no effective relief device is provided. DESCRIPTION The construction of the Mechanical Relief Device is shown in Figs. 1, 2, 3, and 4. Its operating parts consists of a tripping bellows, trigger, toggle mechanism, latch plate, latches attached to a pressure ring, and relief cover. All parts are constructed of corrosion-resistant material and the device is gasketed to make it gas tight. A generous weatherproof hood is provided, not only to protect the cork neoprene gaskets from exposure, but also NEW INFORMATION to prevent the entrance of water after operation of the device. All parts are sturdily constructed to allow the device to operate any number of times without damage to any part except the gasket between the relief cover and the flange. If this gasket is blown out during an operation, a new one must be inserted. Gaskets shown in Figure 3 are cork neoprene and are for use with oil; for Askarel, these gaskets are replaced with cork. The rollers on the latches, as well as the flange surfaces and latch plate with which they come in contact, are hardened. OPERATION The mechanism in the latched or sealed position is shown in Fig. 3, while Fig. 4 shows its maximum venting position. The trigger spring is set at the factory so that tripping will occur at a pressure of ten pounds per square inch. This adjustment should not be changed in the field. Under normal transformer operation through cycles of changing pressure (or vacuum), there are no moving parts in the relief device, and there is no flexing of the bellows until the pressure against the bellows builds up to the required tripping FIG. 2. Components of the Relief Device. EFFECTIVE OCTOBER, 1947

MECHANICAL RELIEF DEVICE, --- FIG. 3. pressure. The trigger spring is overcome and the top of the bellows moves upward pulling the trigger with it. As the toggle moves through the zero point, the operation is accelerated by the trigger spring which is under compression and these combined forces cause the trigger to strike the latch plate and carry it free of the roller latches. These latches then roll inward allowing the relief cover to be moved upward by the pressure of the gases, thus venting the transformer. The operation of the mechanism is clearly illustrated in Figs. 3 and 4. The bellows travel is limited by a shock-absorbing gasket in the top of the hood and the pressure ring comes up against the shock absorbers, protecting the mechanism from any damage. See Fig. 4. After an operation, the device settles back into place with the relief cover against the flange. It is then necessary to reset the device. Proceed as follows: I. Remove the three cap nuts and washers on top of the hood. The Relief Device in Latched or Sealed Position. 2. Remove the hood and lagging. 3. Reset the toggle mechanism by compressing the bellows with the palm of the hand. It will click back into position. 4. Remove the four nuts and washers holding the flange to the transformer boss. 5. Lift the device off the transformer and turn upside down, allowing it to rest on the cap nut end of the pressure bolts. 6. Loosen the three pressure nuts, backing them off until they are near the ends of the pressure bolts. 7. Inspect the gasket S 1317754 on the flange that bears against the relief cover. If this gasket needs replacement, put in a new gasket, cementing it on all sides. To replace this gasket, remove pressure nuts from pressure bolts and lift flange from relief cover, replace gasket in flange and reassemble. The relief cover gasket S 1029060 may also need to be replaced. 8. Lift up on the pressure ring, allowing the latches to drop back into place, making sure that

MICHANICAL RELIEF DEVICE -------------------------------------- Ḻ-- - 6._- they set properly against the flange and latch plate. 9. Tighten the three pressure nuts on the pressure bolts evenly until the gasket between the flange and relief cover is compressed to prevent leakage. 10. Bolt the device back on the transformer. 11. Replace the lagging, hood, cap nut gasket and cap nuts. The device is now ready for operation. MAINTENANCE The only maintenance necessary is resetting after each operation. If the gasket. between the transformer boss and flange has to be replaced, coat it on both sides and edges with red gasket FIG. 4. The Relie Device at Moment a ter Tripping. cement 'If, 7386 and let dry for 15 minutes. Apply a second coat and assemble, wiping excess cement off the edges of the gasket. The same procedure applies to the gasket between the flange and the relief cover.,/./""'important: Before testing the trans! former tank for leaks with pressures greater \ than 8 pounds, reverse the hood and bolt i:l: '\ n place as shown in Fig. 3. Keep spare gaskets and cement on hand. A limited supply is furnished with the transformers. Do not keep gaskets in stock for more than two years. For additional parts, order from the nearest Westinghouse Sales Office, giving the serial and stock order number of the complete transformer as stamped on the nameplate. WESTINGHOUSE ELECTRIC CORPORATION SHARON PLANT TRANSFORMER DIVISION SHARON, PA Printed in U.S.A. (Rep. 9-48)

I.L. 46-711-GA DESCRIPTION OPERATION MAINTENANCE INSTRUCTIONS MECHANICAL RELIEF DEVICE FIG. 1. Cutaway View of Device. THE MECHANICAL RELIEF DEVICE, mounted on the transformer cover, is designed to relieve any dangerous pressures which may build up within the transformer tank. When a predetermined pressure is exceeded, a tripping mechanism unlocks the relief cover, allowing it to rise and vent the tank. It is always possible, although fortunately very unusual, that some fault under the oil level may result in a primary explosion. While the wavefront of pressure created in this way is not as steep as that of a secondary explosion of hydrogen or acetylene and air above the oil, nor the results as violent, the abnormal pressure following an arc is often great enough to rupture the tank if no effective relief device is provided. DESCRIPTION The construction of the Mechanical Relief Device is shown in Figs. 1, 2, 3, and 4. Its operating parts consist of a tripping bellows, trigger, toggle mechanism, latch plate, latches attached to a pressure ring, and relief cover. All parts are constructed of corrosion-resistant material and the device is gasketed to make it gas tight. A generous weatherproof hood is provided, not only to protect the cork neoprene gaskets from exposure, but also SUPERSEDES I.L. 46-71 1-6 to prevent the entrance of water after operation of the device. All parts are sturdily constructed to allow the device to operate any number of times without damage to any part except the gasket between the relief cover and the flange. If this gasket is blown out during an operation, a new one must be inserted. Gaskets shown in Figure 3 are cork neoprene and are for use with oil; for Askarel, these gaskets are replaced with cork. The rollers on the latches, as well as the flange surfaces and latch plate with which they come in contact, are hardened. OPERATION The mechanism in the latched or sealed position is shown in Fig. 3, while Fig. 4 shows its maximum venting position. The trigger spring is set at the factory so that tripping will occur at a pressure of ten pounds per square inch. This adjustment should not be changed in the field. Under normal transformer operation through cycles of changing pressure (or vacuum), there are no parts moving in the relief device, and there is no flexing of the bellows until the pressure against the bellows builds up to the required tripping LA lng " FIG. 2. NUTS Components of the Relief Device. ABSORBERS EFFECTIVE JULY, 1949

MECHANICAL RELIEF DEVICE --- HOOD IN.. NORMAL POSITION FIG. 3. PRESSURE RING pressure. The trigger spring is overcome and the top of the bellows moves upward pulling the trigger with it. As the toggle moves through the zero point, the operation is accelerated by the trigger spring which is under compression and these combined forces cause the trigger to strike the latch plate and carry it free of the roller latches. These latches then roll inward allowing the relief cover to be moved upward by the pressure of the gases, thus venting the transformer. The operation of the mechanism is clearly illustrated in Figs. 3 and 4. The bellows travel is limited by a shock-absorbing gasket in the top of the hood and the pressure ring comes up against the shock absorbers, protecting the mechanism from any damage. See Fig. 4. After an operation, the device settles back into place with the relief cover against the flange. It is then necessary to reset the device. Proceed as follows: 1. Remove the three cap nuts and washers on top of the hood. 2 The Relief Device in Latched or Sealed Position. 2. Remove the hood and lagging. 3. Reset the toggle mechanism by compressing the bellows with the palm of the hand. It will click back into position. 4. Remove the four nuts and washers holding the flange to the transformer boss. 5. Lift the device off the transformer and turn upside down, allowing it to rest on the cap nut end of the pressure bolts. 6. Loosen the three pressure nuts, backing them off until they are near the ends of the pressure bolts. 7. Inspect the gasket (S 1575 657 for oil, 8 1317 752 for Askarel) on the flange that bears against the relief cover. If this gasket needs replacement, put in a new gasket, cementing it on top and bottom. To replace this gasket, remove pressure nuts from pressure bolts and lift flange from relief cover, replace gasket in flange and reassemble. 8. Lift up on the pressure ring, allowing the latches to drop back into place, making sure that -.,.,.

ECHANICAL RELIEF DEVICE ---- -L -4 7 6A AINTENANCE The only maintenance necessary is resetting after each operation. If the gasket between the transformer boss and flange has to be replaced, coat it on both sides and edges with red gasket cement '# 7386 and let dry for 15 minutes. Apply FIG. 4. The Relief Device at Moment after Tripping. they set properly against the flange and latch a light second coat and assemble, wiping excess plate. cement off the edges of the gasket. The same 9. Tighten the three pressure nuts on the pressure bolts evenly but not more than 150 inch lb. torque. procedure applies to the gasket between the flange and the relief cover, except omit cement on edges and exercise care not to get cement in the slit. 10. Bolt the device back on the transformer. Boss gasket (S7ln029 060 for oil, S7lnl66 385 for Important: Before testing the trans- \ Askarel) may need replacing. former tank for leaks with pressures greater,' 11. Replace the lagging, hood, cap nut gasket \ than 8 pounds, reverse the hood and bolt_jt and cap nuts. The device is now ready for operation. \ _in place as shown in Fig. 3. Keep spare gaskets and cement on hand. A limited supply is furnished with the transformers. Do not keep gaskets in stock for more than two years. For additional parts, order from the nearest Westinghouse Sales Office, giving the serial and stock order number of the complete transformer as stamped on the nameplate. WESTINGHOUSE ELECTRIC CORPORATION SHARON PLANT TRANSFORMER DIVISION SHARON, PA. Printed in U.S.A. 3

l.l. 46-711-GC DESCRIPTION OPERATION MAINTENANCE INSTRUCTIONS MECHANICAL RELIEF DEVICE FIG. 1. Cutaway View of Device. THE MECHANICAL RELIEF DEVICE, mounted on the transformer cover, is designed to relieve any dangerous pressures which may build up within the transformer tank. When a predetermined pressure is exceeded, a tripping mechanism unlocks the relief cover, allowing it to rise and vent the tank. It is always possible, although fortunately very unusual, that some fault under the oil level may result in a primary explosion. While the wavefront of pressure created in this way is not as steep as that of a secondary explosion of hydrogen or acetylene and air above the oil, nor the results as violent, the abnormal pressure following an arc is often great enough to rupture the tank if no effective relief device is provided. DESCRIPTION The construction of the Mechanical Relief Device is shown in Figs. 1, 2, 3, and 4. Its operating parts consist of a tripping bellows, trigger, toggle mechanism, latch plate, latches attached to a pressure ring, and relief cover. All parts are constructed of corrosion-resistant material and the device is gasketed to make it gas tight. A generous weatherproof hood is provided, not only to protect the cork-neoprene gaskets from exposure, but also SUPERSEDES I.L 46-711-68 to prevent the entrance of water after operation of the device. All parts are sturdily constructed to allow the device to operate any number of times without damage to any part except the gasket between the relief cover and the flange. If this gasket is blown out during an operation, a new one must be inserted. Gaskets shown in Fig. 3 are corkneoprene for use with oil; for Askarel, these gaskets are replaced with cork. The rollers on the hatches, as well as the flange surfaces and latch plate with which they come in contact, are hardened. Signals: The mechanical relief device may be supplied with semaphore, alarm contacts, or both, as a means of indicating that the unit has operated. The semaphore is locked by the cover as shown in Fig. 3 before operation. When the cover rises during operation the rod of the semaphore slips off the signal latch and is retracted by a spring, Fig. 5. This retracting action uncovers the semaphore or indicator to show that the mechanical relief device has been tripped. The alarm type indicator, Fig. 4, incorporates a double throw microswitch which is depressed to close a normally open circuit for the untripped lng Q NUTS FLANG FIG. 2. Components of the Relief Device. OCK ABSORBERS EFFECTIVE FEBRUARY 1952

MECHANICAL RELIEF DEVICE, --- HOOD IN NORMAL POSITION APPROXIMATE WEIGHT OF ASSEMBLY o 33 LBS. PRESSURE position of the relief device, Fig. 4. When the relief device trips, a pressure plug drops out of position and the microswitch changes to a normally closed circuit. Closing this circuit actuates the alarm. OPERATION The mechanism in the latched or sealed position is shown in Fig. 3, while Fig. 5 shows its maximum venting position. The trigger spring is set at the factory so that tripping will occur at a pressure of ten pounds per square inch. This adjustment should not be changed in the field. Under normal transformer operation through cycles of changing pressure (or vacuum), there are no parts moving in the relief device, and there is no flexing of the bellows until the pressure against the bellows builds up to the required tripping pressure. The trigger spring is overcome and the top of the bellows moves upward pulling the trigger with it. As the toggle moves through the zero point, the operation is accelerated by the trigger spring which is under compression and these 2 RING FIG. 3. The Relief Device in Latched or Sealed Position. : COMMON..? NOR MALLY OPEN L..,_...;.;.;;.,...;;...;;;.;;..;._;.;...:.; -o r- -- N O R M A LL Y CL O S E D - C COMMON OPENS ON C AND CLOSES ON 0 WHEN SWITCH IS MOUNTED ON RELIEF DEVICE WITH SWITCH DEPRESSED FOR UNTRIPPED POSITION OF RELIEF DEVICE. COMMON OPENS ON 0 AND CLOSES ON C WHEN SWITCH IS RELEASED BY TRIPPING OF RELIEF DEVICE. FIG. 4. Alarm Contact in Cocked Position. MICRO SWITCH r - "'IJIII

ECHANICAL RELIEF DEVICE-------------------------------------- - L. 4 6-7 U - 6C I combined forces cause the trigger to strike the latch plate and carry it free of the roller latches. These latches then roll inward allowing the relief cover to be moved upward by the pressure of the gases, thus venting the transformer. The operation of the mechanism is clearly illustrated in Figs. 3 and 5. The bellows travel is limited by a shock-absorbing gasket in the top of the hood and the pressure ring comes up against the shock absorbers, protecting the mechanism from any damage. See Fig. 5. Travel of the hood upward serves to trip the alarm device if one is attached. After an operation, the device settles back into place with the relief cover against the flange. It is then necessary to reset the device. Proceed as follows: 1. Remove the three cap nuts and washers on top of the hood. 2. Remove the hood and lagging. 3. Reset the toggle mechanism by compressing the bellows with the palm of the hand. It will click back into position. 4. Remove the four nuts and washers holding the flange to the transformer boss. 5. Lift the device off the transformer and turn upside down, allowing it to rest on the cap nut end of the pressure bolts. 6. Loosen the three pressure nuts, backing them off until they are near the ends of the pressure bolts. FIG. 5. The Relief Device at Moment after Tripping. 7. Inspect the gasket (S 1575 657 for oil, S 1317 752 for Inerteen or Askarel) on the flange that bears against the relief cover. If this gasket needs replacement put in a new gasket; (A) for oilcement it on the bottom only, and coat the top with petrolatum; (B) for Inerteen or Askarel-cement it all over. To replace this gasket, remove pressure nuts from pressure bolts and lift flange from relief cover, replace gasket in flange and reassemble. Refer figure 3-only gasket S 1575 657 is slotted, gasket S 1317 752 is solid. 8. Lift up on the pressure ring, allowing the latches to drop back into place, making sure that they set properly against the flange and latch plate. 9. Tighten the three pressure nuts on the pressure bolts evenly but not more than 150 inch lb. torque. 10. Bolt the device back on the transformer. Boss gasket (S 1029 060 for oil, S 1166 385 for Askarel) may need replacing. 11. Replace the lagging, hood, cap nut gasket and cap nuts. The device is now ready for operation. 12. If a signal device is provided with the mechanical relief device it is cocked at the time the hood is replaced. The semaphore is cocked by hooking the semaphore rod into the signal latch on the hood. Fig. 3 shows the cocked position. The microswitch alarm is cocked by replacing the switch and its mounting on one of the four relief 3

MECHANICAL RELIEF DEVICE --- device mounting studs, and inserting the pressure plug between the hood and the pressure button of the microswitch. Fig. 4 shows the cocked position. 13. The device is now ready for operation. MAINTENANCE The only maintenance necessary is resetting:_ after each operation. If the gasket between the transformer boss and flange has to be replaced: (A) for oil-coat it on both edges and bottom with cement 7 7386, and on top with petrolatum; (B) for Inerteen or Askarel-coat it all over with cement 7 7386. After applying first coat of cement let dry for 15 minutes, apply a light second coat of cement to the same surfaces, wiping excess cement' off the edges of the gasket. Important: Before testing the transformer tank for leaks with pressures greater than 8 pounds, reverse the hood and bolt it in place as shown in :n.g:. 3.--- ---- - ' Keep spare gaskets and cement on hand. A limited supply is furnished with the transformers. Do not keep gaskets in stock for more than two years. For additional parts, order from the nearest Westinghouse Office, giving the serial and stock order number of the complete transformer as stamped on the nameplate. WESTINGHOUSE ELECTRIC CORPORATION SHARON PLANT TRANSFORMER DIVISION SHARON, PA. Printed in U.S.A.

FIG. 1. I.L. 46-7U-6E DESCRIPTION OPERATION MAINTENANCE INSTRUCTIONS MECHANICAL RELIEF DEVICE Cutaway View o Device. THE MECHANICAL RELIEF DEVICE, mounted on the transformer cover, is designed to relieve any dangerous pressures which may build up within the transformer tank. When a predetermined pressure is exceeded, a tripping mechanism unlocks the relief cover, allowing it to break the sealing gasket and vent the tank. It is always possible, although fortunately very unusual, that some fault under the oil level may result in a primary explosion. While the wavefront of pressure created in this way is not as steep as that of a secondary explosion of hydrogen or acetylene and air above the oil, nor the results as violent, the abnormal pressure following an arc is often great enough to rupture the tank if no effective relief device is provided. DESCRIPTION The construction of the Mechanical Relief Device is shown in Figs. 1, 2, 3, and 4. Its operating parts consist of a tripping bellows, trigger, toggle mechanism, latch plate, latches attached to a pressure ring, and relief cover. All parts are constructed of corrosion-resistant material and the device is gasketed to make it gas tight. A generous weatherproof hood is provided, not only to protect the Cortite * gaskets from exposure, but also to prevent the entrance of water after operation of the device. SUPERSEDES I.L 46-711-60 *Trade-Mark All parts are sturdily constructed to allow the device to operate any number of times without damage to any part except the gasket between the relief cover and the flange. If this gasket is blown out during an operation, a new one must be inserted. The gasket shown in Fig. 3 is Cortite and may be used with oil or Askarel (Inerteen@). The rollers on the latches, as well as the flange surfaces and latch plate with which they come in contact, are hardened. Signals. The mechanical relief device may be supplied with semaphore, alarm contacts, or both, as a means of indicating that the unit has operated. The semaphore is locked by the cover as shown in Fig. 3 before operation. When the cover rises during operation the rod of the semaphore slips off the signal latch and is retracted by a spring, (Fig. 5). This retracting action uncovers the semaphore or indicator to show that the mechanical relief device has been tripped. The alarm type indicator, Fig. 4, incorporates a double throw microswitch which is depressed to close a normally open circuit for the untripped position of the relief device, Fig. 4. When the relief device trips, a pressure plug drops out of position and the microswitch changes to a normally closed circuit. Closing this circuit actuates the LA lng 1M Q\ CAP NUTS SHOCK ABSORBERS FIG. 2. Components o the Relief Device. MAY, 1953

MECHANICAL RELIEF DEVICE -- HOOD IN NORMAL POSITION alarm. No. 1. PRESSURE RING FIG. 3. The Relief Device in Latched or Sealed Position. The microswitch rating appears in Table OPERATION The mechanism in the latched or sealed position is shown in Fig. 3, while Fig. S shows its maximum venting position. The trigger spring is set at the factory so that tripping will occur at a pressure of ten to twelve pounds per square inch. After the mechanism trips, the gasket (S* 1646 548) is subjected to the pressure of the gas space, and will fracture to relieve the transformer tank in the range of ten to twelve pounds per square inch, depending on the rate of pressure rise. Under normal transformer operation through cycles of changing pressure (or vacuum), there are no parts moving in the relief device, and there is no flexing of the bellows until the pressure against the bellows builds up to the required tripping pressure. The trigger spring is overcome and the top of the bellows moves upward pulling the trigger with it. As the toggle moves through the zero point, the operation is accelerated by the trigger spring which is under compression and these 2 RELIEF DE VICE MTG. STUD :\, ;;...c-,...., I I I.----------.... ' ----r--:--- : I I : I --- -;- --r - -- : :-: -._br--- BLACK.- WHITE MICRO SWITCH --------------------RED OR GRE EN WHITE OPENS ON BLACK AND CLOSES ON RED WHEN SWITCH IS MOUNTED ON RELIEF DEVICE WITH SWITCH DE PRESSED FOR UNTRIPPED POSITION OF RELIEF DEVICE. WHITE OPENS ON RED AND CLOSES ON BLACK WHEN SWITCH IS RELEASED BY TRIPPING OF RELIEF DEVICE. FIG. 4. Alarm Contact in Cocked Position.

MECHANICAL RELIEF DEVICE'-------------------------------------- - L._46--7 U - 6E. I combined forces cause the trigger to strike the latch plate and carry it free of the roller latches. These latches then roll inward, allowing the relief cover to be moved upward by the pressure of the gases and to break the sealing gasket, thus venting the transformer. The operation of the mechanism is clearly illustrated in Figs. 3 and 5. The bellows travel is limited by a shock-absorbing gasket in the top of the hood and the pressure ring comes up against the shock absorbers, which protect the mechanism from any damage. See Fig. 5. Travel of the hood upward serves to trip the alarm device if one is attached. After an operation, the device settles back into place with the relief cover against the flange. It is then necessary to reset the device. Proceed as follows: 1. Remove the three cap nuts and washers on top of the hood. 2. Remove the hood and lagging. 3. Reset the toggle mechanism by compressing the bellows with the palm of the hand. It will click back into position. 4. Remove the four nuts and washers holding the flange to the transformer boss. 5. Lift the device off the transformer and turn upside down, allowing it to rest on the cap nut end of the pressure bolts. FIG. 5. The Relief Device at Moment after Tripping. 6. Loosen the three pressure nuts, backing them off until they are near the ends of the pressure bolts. 7. Inspect the gasket (S 71 1646 548 for oil or Askarel) on the flange that bears against the relief cover. If this gasket needs replacement, remove pressure nuts from pressure bolts, lift flange, clean off all the old gasket and cement, and proceed as follows: (a) Paint bottom of gasket recess in flange with a light coat of cement 71 7386 and let dry; (b) Paint bottom of gasket with a light coat of cement and allow to become tacky; (c) Place gasket in gasket recess with tacky bottom down, and hold flat with relief cover until dry; (d) Paint top of gasket with light coat of cement, replace relief cover and reassemble. NOTICE: Do not paint edges of gasket, and do not use an excess of cement. Any extra cement will flow from gasket and recess to cement the flange and the relief cover together, thus requiring a pressure in excess of 10-12 psi to open the relief device. 8. Lift up on the pressure ring, allowing the latches to drop back into place, making sure that they set properly against the flange and latch plate. The latch plate should be centered between the latches. 3

MECHANICAL RELIEF DEVICE --- 9. Tighten the three pressure nuts on the pressure bolts evenly but not more than 150 inch-lb. torque. 10. Bolt the device back on the transformer. Boss gasket (S 1029 060 for oil, S 1166 385 for Askarel) may need replacing. 11. Replace the lagging, hood, cap nut gasket and cap nuts. The device is now ready for operation. 12. If a signal device is provided with the mechanical relief device it is cocked at the time the hood is replaced. The semaphore is cocked by hooking the semaphore rod into the signal latch on the hood. Fig. 3 shows the cocked position. The microswitch alarm is cocked by replacing the switch and its mounting on one of the four relief device mounting studs, and inserting the pressure plug between the hood and the pressure button of the microswitch. Fig. 4 shows the cocked position. 13. The device is now ready for operation. MAINTENANCE The only maintenance necessary is resetting after each operation. If the gasket between the transformer boss and flange has to be replaced: (A) for oil-coat it on both edges and bottom with cement 7386, and on top with petrolatum; (B) for Inerteen or Askarel-coat it all over with cement 7386. After applying first coat of cement let dry for 15 minutes, apply a light second coat of cement to the same surfaces, wiping excess cement off the edges of the gasket. Important: Before testing the transformer tank for leaks with pressures greater than 8 pounds, reverse the hood and bolt it in place as shown in Fig. 3. Note: The mechanical relief device will withstand full vacuum, and need not be removed from the transformer tank during any vacuum treatment. TABLE NO. I NON-INDUCTIVE INDUCTIVE LOAD VOLTAGE LOAD-AMPS. AMPS. L/R = 026* 125 A-C 10 10 250 A C 5 5 0.5 12s n.c 0.05 250 D-C 0.25 0.025 *Equal to or less than.026. If greater, refer to factory for adjusted rating. Important: When checking circuits through this device, it is necessary to follow Table No. I. This means that a low voltage bell ringer cannot be used unless switched through a high impedance relay. An indicating light type device is generally recognized as best for checking circuits through instruments containing microswi tches of similar capacities. Keep spare gaskets and cement on hand. A limited supply is furnished with the transformers. Do not keep gaskets in stock for more than two years. For additional parts, order from the nearest Westinghouse Office, giving the serial and stock order number of the complete transformer as stamped on the nameplate. WESTINGHOUSE ELECTRIC CORPORATION SHARON PLANT TRANSFORMER DIVISION SHARON, PA. (Rep. 9-53) Printed in U.S.A.

FIG. 1. Cutaway View of Device THE MECHANICAL RELIEF DEVICE, mounted on the transformer cover, is designed to relieve any dangerous pressures which may build up within the transformer tank. When a predetermined pressure is exceeded, a tripping mechanism unlocks the relief cover, allowing it to break the gasket seal and vent the tank. It is always possible, although fortunately very unusual, that some fault under the oil level may result in a primary explosion. While the wavefront of pressure created in this way is not as steep as that of a secondary explosion of hydrogen or acetylene and air above the oil, nor the results as violent, the abnormal pressure following an arc is often great enough to rupture the tank if no effective relief device is provided. DESCRIPTION The construction of the Mechanical Relief Device is shown in Figs. 1, 2, 3, and 4. Its operating parts consist of a tripping bellows, trigger, toggle mechanism, latch plate, latches attached to a pressure ring, and relief cover. All parts are constructed of corrosion-resistant material and the device is gasketed to make it gas tight. A generous weatherproof hood is provided, not only to protect the Cortite * gaskets from exposure, but also to prevent the entrance of water after operation of the device. SUPERSEDES t.l. 46-711-6E Trade-Mark I.L. 46-711-GF DESCRIPTION OPERATION MAINTENANCE INSTRUCTIONS MECHANICAL RELIEF DEVICE All parts are sturdily constructed to allow the device to operate any number of times without damage to any part. If the gasket between the relief cover and the flange is damaged for any reason, a new one must be inserted. The gasket shown in Fig. 3 is Cortite and may be used with oil or Askarel (Inerteen@). The rollers on the latches, as well as the flange surfaces and latch plate with which they come in contact, are hardened. Signals. The mechanical relief device may be supplied with semaphore, alarm contacts, or both, as a means of indicating that the unit has operated. The semaphore is locked by the cover as shown in Fig. 3 before operation. When the cover rises during operation the rod of the semaphore slips off the signal latch and is retracted by a spring, (Fig. 5). This retracting action uncovers the semaphore or indicator to show that the mechanical relief device has been tripped. The alarm type indicator, Fig. 4, incorporates a double throw microswitch which is depressed to close a normally open circuit for the untripped position of the relief device, Fig. 4. When the relief device trips, a pressure plug drops out of position and the microswitch changes to a normally closed circuit. Closing this circuit actuates the LAG I NG BELLOWS / I I FLANG v1?ck NUTS FIG. 2. Components of the Relief Device ABSORBERS APRIL, 1955

MECHANICAL RELIEF DEVICE --- HOOD IN "JORMAL POSITION alarm. No. 1. APPROXIMATE WEIGHT OF ASSEMBLY, 33 LBS. SHOCK ABSORBER PRESSURE RING FIG. 3. The Relief Device in Latched or Sealed Position The microswitch rating appears in Table OPERATION The mechanism in the latched or sealed position is shown in Fig. 3, while Fig. 5 shows its maximum venting position. The trigger spring is set at the factory so that tripping will occur at a pressure of ten to twelve pounds per square inch. After the mechanism trips, the gasket seal will be broken by the pressure of the gas space, and will relieve the transformer tank in the range of ten to twelve pounds per square inch, depending on the rate of pressure rise. Under normal transformer operation through cycles of changing pressure (or vacuum), there are no parts moving in the relief device, and there is no flexing of the bellows until the pressure against the bellows builds up to the required tripping pressure. The trigger spring is overcome and the top of the bellows moves upward pulling the trigger with it. As the toggle moves through the zero point, the operation is accelerated by the trigger spring which is under compression and these 2 r---- BLACK iis r WHITE MICRO SWITCH, RED OR GREEN WHITE OPENS ON BLACK AND CLOSES ON RED WHEN SWITCH IS MOUNTED ON RELIEF DEVICE WITH SWITCH DEPRESSED FOR UNTRI PPED POSITION OF RELIEF DEVICE. WHITE OPENS ON RED AND CLOSES ON BLACK WHEN SWITCH IS RELEASED BY TRIPPING OF RELIEF DEVICE. FIG. 4. Alarm Contact in Cocked Position

MECHANICAL RELIEF DEVICE------------------_.;.: '.;;; L :.. 4.-..;- 6 7.- 11 ;;.. -.-. 6F I combined forces cause the trigger to strike the latch plate and carry it free of the roller latches. These latches then roll inward, allowing the relief cover to be moved upward by the pressure of the gases and to break the gasket seal thus venting the transformer. The operation of the mechanism is clearly illustrated in Figs. 3 and 5. The bellows travel is limited by a shock-absorbing gasket in the top of the hood and the pressure ring comes up against the shock absorbers, which protect the mechanism from any damage. See Fig. 5. Travel of the hood upward serves to trip the alarm device if one is attached. After an operation, the device settles back into place with the relief cover against the flange. It is then necessary to reset the device. Proceed as follows: 1. Remove the three cap nuts and washers on top of the hood. 2. Remove the hood and lagging. 3. Reset the toggle mechanism by compressing the bellows with the palm of the hand. It will click back into position. 4. Remove the four nuts and washers holding the flange to the transformer boss. 5. Lift the device off the transformer and turn upside down, allowing it to rest on the cap nut end of the pressure bolts. FIG. 5. The Relief Device at Moment after Tripping 6. Loosen the three pressure nuts, backing them off until they are near the ends of the pressure bolts. 7. Inspect the gasket seal and the gasket (S 11: 1646 548 for Oil or Askarel) to see if the sealing material has hardened and damaged the gasket. In most cases the sealing material will be still plastic and no action will be necessary. If however the gasket has been damaged and needs replacement, remove pressure nuts from pressure bolts, lift flange, clean off all the old gasket and sealing compound, and proceed as follows: (a) Paint bottom of gasket recess in flange with a light coat of plastic lead seal 11:8138-3. (b) Place gasket in gasket recess. (c) Paint top of gasket with a light coat of plastic lead seal, replace relief cover and reassemble. NOTICE: Do not use an excess of sealing compound as any extra will flow from gasket and recess. 8. Lift up on the pressure ring, allowing the latches to drop back into place, making sure that they set properly against the flange and latch plate. The latch plate should be centered between the latches. 9. Tighten the three pressure nuts on the pressure bolts evenly but not more than 150 inch-lb. torque. 3

MECHANICAL RELIEF DEVICE -- 10. Bolt the device back on the transformer. Boss gasket (Sl'li 1029 060 for oil, S7li 1166 385 for Askarel) may need replacing. 11. Replace the lagging, hood, cap nut gasket and cap nuts. The device is now ready for operation. 12. If a signal device is provided with the mechanical relief device it is cocked at the time the hood is replaced. The semaphore is cocked by hooking the semaphore rod into the signal latch on the hood. Fig. 3 shows the cocked position. The microswitch alarm is cocked by replacing the switch and its mounting on one of the four relief device mounting studs, and inserting the pressure plug between the hood and the pressure button of the microswitch. Fig. 4 shows the cocked position. 13. The device is now ready for operation. MAINTENANCE The only maintenance necessary is resetting after each operation. If the gasket between the transformer boss and flange has to be replaced: (A) for oil-coat it on both edges and bottom with cement 7li 7386, and on top with petrolatum; (B) for Inerteen or Askarel-coat it all over with cement 7li 7386. After applying first coat of cement let dry for 15 minutes, apply a light second coat of cement to the same surfaces, wiping excess cement off the edges of the gasket. Important: Before testing the transformer tank for leaks with pressures greater than 8 pounds, reverse the hood and bolt it in place as shown in Fig. 3. Note: The mechanical relief device will withstand full vacuum, and need not be removed from the transformer tank during any vacuum treatment. TABLE NO. I NON-INDUCTIVE INDUCTIVE LOAD VOLTAGE LOAD-AMPS. AMPS. L/R = 026* 125 A-C 10 10 250 A-C 5 5 0.5 125 D-C 0.05 250 D-C 0.25 0.025 *Equal to or less than.026. If greater, refer to factory for adjusted rating. Important: When checking circuits through this device, it is necessary to follow Table No. 1. This means that a low voltage bell ringer cannot be used unless switched through a high impedance relay. An indicating light type device is generally recognized as best for checking circuits through instruments containing microswitches of similar capacities. Keep spare gaskets and cement on hand. A limited supply is furnished with the transformers. Do not keep gaskets in stock for more than two years. For additional parts, order from the nearest Westinghouse Office, giving the serial and stock order number of the complete transformer as stamped on the nameplate. WESTINGHOUSE ELECTRIC CORPORATION SHARON PLANT TRANSFORMER DIVISION SHARON, PA. Printed in U.S.A.

, FIG. 1. Cutaway View of Device THE MECHANICAL RELIEF DEVICE, mounted on the transformer cover, is designed to relieve any dangerous pressures which may build up within the transformer tank. When a predetermined pressure is exceeded, a tripping mechanism unlocks the relief cover, allowing it to break the gasket seal and vent the tank. It is always possible, although fortunately very unusual, that some fault under the oil level may result in a primary explosion. While the wavefront of pressure created in this way is not as steep as that of a secondary explosion of hydrogen or acetylene and air above the oil, nor the results as violent, the abnormal pressure following an arc is often great enough to rupture the tank if no effective relief device is provided. DESCRIPTION The construction of the Mechanical Relief Device is shown in Figs. 1, 2, 3, and 4. Its operating parts consist of a tripping bellows, trigger, toggle mechanism, latch plate, latches attached to a pressure ring, and relief cover. All parts are constructed of corrosion-resistant material and the device is gasketed to make it gas tight. A generous weatherproof hood is provided, not only to protect the gaskets from exposure, but also to prevent the entrance of water after operation of the device. SUPERSEDES I.L. 46-711-6F Trade-Mark I.L. 46-711-GG DESCRIPTION OPERATION MAINTENANCE INSTRUCTIONS MECHANICAL RELIEF DEVICE All parts are sturdily constructed to allow the device to operate any number of times without damage to any part. If the gasket between the relief cover and the flange is damaged for any reason, a new one must be inserted. The gasket shown in Fig. 3 is a Buna-N compound and may be used with oil or Askarel (Inerteen@). The rollers on the latches, as well as the flange surfaces and latch plate with which they come in contact, are hardened. Signals. The mechanical relief device may be supplied with semaphore, alarm contacts, or both, as a means of indicating that the unit has operated. The semaphore is locked by the cover as shown in Fig. 3 before operation. When the cover rises during operation the rod of the semaphore slips off the signal latch and is retracted by a spring, (Fig. 5). This retracting action uncovers the semaphore or indicator to show that the mechanical relief device has been tripped. The alarm type indicator, Fig. 4, incorporates a double throw microswitch which is depressed to close a normally open circuit for the untripped position of the relief device, Fig. 4. When the relief device trips, a pressure plug drops out of position and the microswitch changes to a normally closed circuit. Closing this circuit actuates the LA lng - FIG. 2. ' CAP NUTS Components of the Relief Device J HOCK ABSORBERS OCTOBER, 1955

MECHANICAL RELIEF DEVICE --- alarm. No. 1. HOOD IN NORMAL POSITION APPROXIMATE WEIGHT OF ASSEMBLY = 25 LBS. SHOCK ABSORBER PRESSURE RING FIG. 3. The Relief Device in Latched or Sealed Position The microswitch rating appears in Table OPERATION The mechanism in the latched or sealed position is shown in Fig. 3, while Fig. 5 shows its maximum venting position. The trigger spring is set at the factory so that tripping will occur at a pressure of ten to twelve pounds per square inch. After the mechanism trips, the gasket seal will be broken by the pressure of the gas space, and will relieve the transformer tank in the range of ten to twelve pounds per square inch, depending on the rate of pressure rise. Under normal transformer operation through cycles of changing pressure {or vacuum), there are no parts moving in the relief device, and there is no flexing of the bellows until the pressure against the bellows builds up to the required tripping pressure. The trigger spring is overcome and the top of the bellows moves upward pulling the trigger with it. As the toggle moves through the zero point, the operation is accelerated by the trigger spring which is under compression and these 2 RELIEF DEVICE MTG. STUD :l '. : \;.. "" : 1 I I I.------- --. ' - -- T ---., t II t : I I ::I ---- --!. --- - -- I I I : tl! ---- BLACK WHITE MICRO SWITCH '----------- RED OR GREEN WHITE OPENS ON BLACK AND CLOSES ON RED WHEN SWITCH IS MOUNTED ON RELIEF DEVICE WITH SWITCH DEPRESSED FOR UNTRIPPED POSITION OF RELIEF DEVICE. WHITE OPENS ON RED AND CLOSES ON BLACK WHEN SWITCH IS RELEASED BY TRIPPING OF RELIEF DEVICE. FIG. 4. Alarm Contact in Cocked Position

' MECHANICAL RELIEF DEVICE ----..: L::.:...;:46-;,:,;11:;::1-6::::\; I combined forces cause the trigger to strike the latch plate and carry it free of the roller latches. These latches then roll inward, allowing the relief cover to be moved upward by the pressure of the gases and to break the gasket seal thus venting the transformer. The operation of the mechanism is clearly illustrated in Figs. 3 and 5. The bellows travel is limited by a shock-absorbing gasket in the top of the hood and the pressure ring comes up against the shock absorbers, which protect the mechanism from any damage. See Fig. 5. Travel of the hood upward serves to trip the alarm device if one is attached. After an operation, the device settles back into place with the relief cover against the flange. It is then necessary to reset the device. Proceed as follows: 1. Remove the three cap nuts and washers on top of the hood. 2. Remove the hood and lagging. 3. Reset the toggle mechanism by compressing the bellows with the palm of the hand. It will click back into position. 4. Remove the four nuts and washers holding the flange to the transformer boss. FIG. 5. The Relief Device at Moment after Tripping 5. Lift the device off the transformer and turn upside down, allowing it to rest on the cap nut end of the pressure bolts. 6. Loosen the three pressure nuts, backing them off until they are near the ends of the pressure bolts. 7. Inspect the gasket (55')155-D-5555-P-l for Oil or Askarel) to see if it has been damaged. In most cases no action will be necessary. If, however, the gasket has been damaged and needs replacement, remove pressure nuts from pressure bolts, lift flange, clean off the gasket surface carefully and proceed as follows: (a) Apply a light coat of Silicone Lubricant )')! 5861-4 to the bottom of the gasket recess in the flange. (b) Place gasket in gasket recess. (c) Apply a light coat of Lubricant to the top of the gasket, replace relief cover and reassemble. NOTICE: Do not use cement or any material which may bond the relief cover to the flange or gasket. 8. Lift up on the pressure ring, allowing the latches to drop back into place, making sure that they set properly against the flange and latch plate. The latch plate should be centered between the latches. 9. Tighten the three pressure nuts on the pressure bolts evenly but not more than 125 inch-lb. torque. 3

MECHANICAL RELIEF DEVICE -- 10. Bolt the device back on the transformer. Boss gasket (Sll! 1029 060 for oil, Sll! 1166 385 for Askarel) may need replacing. 11. Replace the lagging, hood, cap nut gasket and cap nuts. The device is now ready for operation. 12. If a signal device is provided with the mechanical relief device it is cocked at the time the hood is replaced. The semaphore is cocked by hooking the semaphore rod into the signal latch on the hood. Fig. 3 shows the cocked position. The microswitch alarm is cocked by replacing the switch and its mounting on one of the four relief device mounting studs, and inserting the pressure plug between the hood and the pressure button of the microswitch. Fig. 4 shows the cocked position. 13. The device is now ready for operation. MAINTENANCE The only maintenance necessary is resetting after each operation. If the gasket between the transformer boss and flange has to be replaced: (A) for oil-coat it on both edges and bottom with cement jj! 7386, and on top with petrolatum; (B) for Inerteen or Askarel-coat it all over with cement 7l! 7386. After applying first coat of cement let dry for 15 minutes, apply a light second coat of cement to the same surfaces, wiping excess cement off the edges of the gasket. Important: Before testing the transformer tank for leaks with pressures greater than 8 pounds, reverse the hood and bolt it in place as shown in Fig. 3. Note: The mechanical relief device will withstand full vacuum, and need not be removed from the transformer tank during any vacuum treatment. TABLE NO. I NON-INDUCTIVE INDUCTIVE LOAD VOLTAGE LOAD-AMPS. AMPS. L/R = 026* 125 A-C 10 10 250 A-C 5 5 125 D-C 0.5 0.05 250 D-C 0.25 0.025 *Equal to or less than.026. If greater, refer to factory for adjusted rating. lmpol'lant: When checking circuits through this device, it is necessary to follow Table No. 1. This means that a low voltage bell ringer cannot be used unless switched through a high impedance relay. An indicating light type device is generally recognized as best for checking circuits through instruments containing microswitches of similar capacities. Keep spare gaskets and cement on hand. A limited supply is furnished with the transformers. For additional parts, order from the nearest Westinghouse Office, giving the serial and stock order number of the complete transformer as stamped on the nameplate. WESTIN GHOUSE ELECTR IC CO RPORATION SHARON PLANT TRANS FORMER DIVISION SHARON, PA. Printed in U.S.A,

I.L. 46-7U- 6H DESCRIPTION OPER ATION MAINTEN ANCE I N S T R U C T I O N S MECHANICAL RELIEF DEVICE FIG. 1. Cutaway View of Device THE MECHANICAL RELIEF DEVICE, mounted on the transformer cover, is designed to relieve any dangerous pressures which may build up within the transformer tank. When a predetermined pressure is exceeded, a tripping mechanism unlocks the relief cover, allowing it to break the gasket seal and vent the tank. It is always possible, although fortunately very unusual, that some fault under the oil level may result in a primary explosion. While the wavefront of pressure created in this way is not as steep as that of a secondary explosion of hydrogen or acetylene and air above the oil, nor the results as violent, the abnormal pressure following an arc is often great enough to rupture the tank if no effective relief device is provided. DESCRIPTION The construction of the Mechanical Relief Device is shown in Figs. 1, 2, 3, and 4. Its operating parts consist of a tripping bellows, trigger, toggle mechanism, latch plate, latches attached to a pressure ring, and relief cover. All parts are constructed of corrosion-resistant material and the device is gasketed to make it gas tight. A generous weatherproof hood is provided, not only to protect the gaskets from exposure, but also to prevent the entrance of water after operation of the device. SUPERSEDES I.L. 46-711-6G *Tude-Mark All parts are sturdily constructed to allow the device to operate any number of times without damage to any part. If the gasket between the relief cover and the flange is damaged for any reason, a new one must be inserted. The gasket shown in Fig. 3 is a Buna-N compound and may be used with oil or Askarel (Inerteen@). The rollers on the latches, as well as the flange surfaces and latch plate with which they come in contact, are hardened. Signals. The mechanical relief device may be supplied with semaphore, alarm contacts, or both, as a means of indicating that the unit has operated. The semaphore is locked by the cover as shown in Fig. 3 before operation. When the cover rises during operation the rod of the semaphore slips out of the signal latch and is retracted by a spring, (Fig. 5). This retracting action uncovers the semaphore or indicator to show that the mechanical relief device has been tripped. The alarm type indicator, Fig. 4, incorporates a double throw microswitch which is depressed to close a normally open circuit for the untripped position oi the relief device, Fig. 4. When the relief device trips, a pressure plug drops out of position and the microswitch changes to a normally closed circuit. Closing this circuit actuates the r...,.,.,_,,.,.,,_,._. - --- ---"- -----.,...,.-.--,." - ---- -o - ---- -- - - ----- - -- ---.."'""" -,. f I r t f I t l f l BELLOWS I L..._.,----.,_M_O - ------- - FIG. 2. Components of the Relief Device I l - JULY, 1958

MECHANICAL RELIEF DEVICE -- alarm. No. 1. HOOD IN NORMAL POSITION APPROX I MATE WE IGHT OF ASSEMBLY = 25 LBS. SHOCK ABSORBER PRESSURE RING FIG. 3. The Relief Device in Latched or Sealed Position The microswitch rating appears in Table OPERATION The mechanism in the latched or sealed position is shown in Fig. 3, while Fig. 5 shows its maximum venting position. The trigger spring is set at the factory so that tripping will occur at a pressure of ten to twelve pounds per square inch. After the mechanism trips, the gasket seal will be broken by the pressure in the gas space; this will relieve the transformer tank in the range of ten to twelve pounds per square inch, depending on the rate of pressure rise. Under normal transformer operation through cycles of changing pressure (or vacuum), there are no parts moving in the relief device, and there is no flexing of the bellows until the pressure against the bellows builds up to the required tripping pressure. The trigger spring is overcome and the top of the bellows moves upward pulling the trigger with it. As the toggle moves through the zero 2 point, the operation is accelerated by the trigger spring which is under compression and these combined forces cause the trigger to strike the latch NO BLACK WHITE =s:::::s RED WHITE NORMALLY CLOSES ON BLACK WHEN RELIEF DEVICE HAS OPERATED, THE BUTTON IS EXTENDED AND WHITE HAS CLOSED ON RED. FIG. 4. Alarm Contact in Cocked Position