SOLENOID VALVES INDEX VALVES GENERAL CATALOG SERIES

Similar documents
Achieves high specs as a key valve for mid-sized actuators. SOLENOID VALVES The powerful and low current 280 series solenoid valves inherited the feat

SOLENOID VALVES SERIES

SOLENOID VALVES, SERIES

SOLENOID VALVES 010 SERIES INSTRUCTION MANUAL

Solenoid Valves HJE Series (2, 3, 5-port pilot type solenoid valves)

SOLENOID VALVES. HEB series SOLENOID VALVES EA, EB SERIES. (2, 3-port pilot type solenoid valves) 53mm. 10mm

Solenoid Valves JC, JE Series

SOLENOID VALVES, SERIES

SOLENOID VALVES SERIES

SOLENOID VALVES JC JE SERIES INSTRUCTION MANUAL

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

SOLENOID VALVES, SERIES

SOLENOID VALVES SERIES

We have achieved Miniaturization and Low Power -port valves for high value-added new generation New Valve for the New Century Thin and compact Valve w

SOLENOID VALVES SERIES

SOLENOID VALVES SERIES

SOLENOID VALVES SERIES

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

MULTISTAGE MICRO EJECTORS

SOLENOID VALVES 300 SERIES INSTRUCTION MANUAL

The first in the world!

BKUA002 Ver.1.0. Vacuum MICRO EJECTOR. INSTRUCTION MANUAL Ver.1.0

MICRO EJECTORS CONTENTS

The first in the world!

Micro 3-port Solenoid Valve 005 Series

MICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves.

SOLENOID VALVES VALVES GENERAL CATALOG SERIES INDEX

Series VQ Port Solenoid Valve

3 Port Solenoid Valve

ROD SLIDERS INDEX ACTUATORS GENERAL CATALOG. Characteristics 779. Handling Instructions, and Precautions 783

MANIFOLD REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MANIFOLD REGULATORS

3 Port Solenoid Valve

Specifications. Fluid Ambient and fluid temperature ( C)

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

SOLENOID VALVES VALVES GENERAL CATALOG SERIES INDEX

Manual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry

Series SYJ300/500/700

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

3 Port Solenoid Valve. Copper free No copper used for sections in contact with fluids. N.C. 1(P) 2(A)

3 Port Solenoid Valve. Copper-free specifications. The fluid contacting section is copper-free and the standard style can be used as it is.

3MA0/3MB0. Small pneumatic valve. 3 port direct acting valve CONTENTS. Space saving Valves are compactly designed with widths of 10 mm

KNOCK CYLINDERS CONTENTS ACTUATORS GENERAL CATALOG. Caution KNOCK CYLINDERS

ACTUATORS GENERAL CATALOG

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

ELECTRO-PNEUMATIC TRANSDUCING REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS.

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

ACTUATORS GENERAL CATALOG

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Seven Features of the Koganei Vacuum Valve

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Soft Start-up Valve. AV2000/3000/4000/5000 Series

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

ETR Series ELECTRO-PNEUMATIC TRANSDUCING REGULATORS. Electro-Pneumatic Transducing Regulators

Compact Slide. Series MXH ø6, ø10, ø16, ø20

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Series VP3145/3165/3185

Air Valve AIR-PILOTED VALVES

Pilot Operated 2 Port Solenoid Valve for Dry Air

Vacuum pump system type

3 Port Solenoid Valve

HMV/HSV. Manual selector valve. 4-port valve CONTENTS

Free position locking flat and compact cylinder UFCD Series

3 Port Solenoid Valve Direct Operated Poppet Type

HL (AZH) LIMIT SWITCHES

5 Port Pilot Solenoid Valve/Body Ported Type Base Ported Type. Closed Center DS3330/DS3300. How to Order - Body Ported Type

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

SLIDE TABLES CONTENTS

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Series ISA. Air Catch Sensor. For Detection of Work Presence

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

240% 19% reduced. Compact Slide. MXH Series. Improved by up to. With new high rigidity linear guide. 369g. ø6, ø10, ø16, ø g.

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Pilot Operated 2 Port Solenoid Valve for Dry Air

Non-Contact Sensor for Workpiece Placement Verification

Compact Proportional Solenoid Valve

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

Series VP3145/3165/3185

MAGNET TYPE RODLESS CYLINDERS SERIES CONTENTS

Port Flow Rate/ Function Series Actuators Page Number Size Factor

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Series ZM Applications

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

Free Mount Cylinder. Series. Series CU CAT.EUS20-95 B -UK. Space-saving. Auto Switch Capable P. 4, 23, 37 P. 45 P. 43

SG-B1 SERIES / SG-A1 SERIES

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Compact direct acting precision regulator

MULTI SLIDERS CONTENTS

HN B G1/US B G2/US B G3

Individual wiring manifold Sub base porting Direct mount type/din rail mount type M4GB1 2 3/M4GB1 2 3-D Series

Product series extended even more! Non-rotating Type. Offers 3 types of non-rotating operation types. push type cylinders. pull type cylinders

ACTUATORS GENERAL CATALOG

Maintenance & Repair Manual

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Transcription:

Presenting our CAD drawing data catalog VALVES GENERAL CATALOG SOLENOID VALVES SERIES INDEX Characteristics 434 Variations 436 Table of Cylinder Operating Speed 438 Handling Instructions and Precautions 439 Manifold Disassembly Diagram, Unit Adding Procedure 443 Operating Principle, and Symbol 445 Order Code 447 Solenoid Valves GF Series 461 Specifications 46 Dimensions 465 Solenoid Valves GF Series 473 Specifications 474 Dimensions 477 Solenoid Valves GF18 Series 485 Specifications 486 Dimensions 489 GF Series Specifications Confirmation Form 497 433

New valves, further improving user friendlier operability. SERIES SOLENOID VALVES The GF series solenoid valves inherit the development concept of the F series solenoid valves to achieve easy operability even further in the single valve range. While mounting the same compact, large flow capacity valves as the F series, the GF series achieves the low power consumption of 0.5W (DC4V), and also adds AC0V specifications to the product range. It also offers excellent assembly and maintenance ability for monoblock manifolds (base piping, direct piping) in a confined space. It is the Best Price & Global Model equipped with simple but basic functions. 1. More compact, and larger flow rate Flow rate up by ~3. 3 times with the same valve width (Koganei company comparison). Solenoid valves 1 series Solenoid valves GF series External pilot specification External pilot (positive pressure) specification allows the main pressure to operate from 0 MPa. Vacuum specification can also be selected. Effective area Effective area 4.0mm mm P port Supply port for external pilot. A higher level of easy operation By replacing the output blocks for base piping with the direct piping version offers fast change of the valve piping. (Except monoblock manifold F type, monoblock compact manifold A type and F type) Female thread block and fitting blocks can be selected. Fitting block J6 [] ]\ Fitting block J5 Female thread block 3. Base piping Direct piping Archives power consumption of 0.5W (current 1mA, DC4V) Power consumption per one valve (for DC4V specification) Fitting block tube size Model Series GF GF GF18 J5 4 6 8 Offers individual air supply and exhaust. Placing dedicated air supply or exhaust spacers between the manifold and valve offers individual air supply or exhaust. J6 6 8 434

SOLENOID VALVES SERIES Valve width: mm Effective area: 5mm Applicable cylinder bore sizes: 50 SOLENOID VALVES SERIES Valve width: mm Effective area: mm Applicable cylinder bore sizes: 4080 SOLENOID VALVES SERIES Valve width: 18mm Effective area: 18mm Applicable cylinder bore sizes: 500 435

GF SERIES VARIATIONS Single Valve Unit Valves can be used as a single unit by attaching an input port block. Mounting brackets are also provided. Output port specifications With sub-base For single unit or manifold Series Female thread With female thread block With fitting block Rc 1/8 Rc 1/4 M5 Rc 1/8 Rc 1/4 4 6 8 GF GF GF 18 Order code p. 448,449 GF series dimensions p. 465 GF series dimensions p. 477 GF18 series dimensions p. 489 With fitting block With female thread block With A type sub-base With mounting bracket Illustration shows the GF series -position single solenoid -position double solenoid 3-position double solenoid Photos show GF series with A type sub-base. 436

Monoblock Manifold A Type (Base Piping Type) This base piping type manifold achieves in both maintenance and cost performance. By replacing the output block, also it can be used as a direct piping type. With fitting block With female thread block Order code p. 450,451 GF series dimensions p. 469 GF series dimensions p. 481 GF18 series dimensions p. 493 Monoblock Compact Manifold A Type (Base Piping Type) Manifold for base piping type achieves low height. Fitting specification Female thread specification Order code p. 45,453 GF series dimensions p. 470 GF series dimensions p. 48 Monoblock Manifold F Type (Direct Piping Type) Manifold for direct piping type achieves excellent cost performance. With fitting block With female thread block Order code p. 454,455 GF series dimensions p. 469 Monoblock Compact Manifold F Type (Direct Piping Type) Manifold for direct piping type With fitting block With female thread block achieves low height. GF series dimensions p. 481 GF18 series dimensions p. 493 Order code p. 456,457 GF series dimensions p. 470 GF series dimensions p. 48 Split Manifold Non-Plug-in Type Allows easy addition or removal of the manifolds stations. This system offers more flexibility in responding to changes in specifications. Order code p. 458,459 With manifold port fitting block With valve port fitting block With manifold port female thread block With valve port female thread block GF series dimensions p. 471 GF series dimensions p. 483 GF18 series dimensions p. 494 437

Table of Cylinder Operating Speed (Reference) 1. Cylinder mounting direction: vertical Series Cylinder speed mm/s NEW Pen Cylinder Series Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 0mm Piping outer diameter inner diameter length: 6400mm Cylinder seriesconditionscylinder bore size mm Slim Cylinder Series Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 0mm Piping (outer diameter inner diameter length): 6400mm 0 GF series Effective area 5mm 300 450 600 750 0 GF series Effective area mm 300 450 600 750 0 GF18 series Effective area 18mm 300 450 600 750 : Use each cylinder type within their operating speed ranges. : Cylinder speed is restricted by the piping port orifice size. Remark: For load ratio of other than 50%, see the Cylinder Operating Speed in the lists of specifications for each valve. 5 3 40 50 NEW DYNA Cylinder Series Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 0mm Piping (outer diameter inner diameter length): 7.500mm 63 80 0. Cylinder mounting direction: horizontal (Roller bearing: Friction coefficient µ =0.1) Series GF series Effective area 5mm GF series Effective area mm GF18 series Effective area 18mm Cylinder speed mm/s 0 300 450 600 750 0 300 450 600 750 0 300 450 600 750 NEW Pen Cylinder Series Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 0mm Piping (outer diameter inner diameter length): 6400mm Cylinder seriesconditionscylinder bore size mm Slim Cylinder Series Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 0mm Piping (outer diameter inner diameter length): 6400mm : Use each cylinder type within their operating speed ranges. : Cylinder speed is restricted by the piping port orifice size. Remark: For load ratio of other than 50%, see the Cylinder Operating Speed in the lists of specifications for each valve. 5 3 40 NEW DYNA Cylinder Series Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 0mm Piping (outer diameter inner diameter length): 7.500mm 50 63 80 0 438

Handling Instructions and Precautions Solenoid Plug connector Internal circuit DC1V, DC4V Solenoid with LED indicator (surge suppression) Lead wire DC1VRed DC4VRed COM Lead wire : Black LED indicator Light emitting diode LED indicator : Red Attaching and removing plug connector Use fingers to insert the connector into the pin, push in until the lever claw catches on the convex section on the connector housing, and complete the connection. To remove the connector, squeeze the lever along with the connector, lift the lever claw up from the convex section on the connector housing, and pull out. Connector housing Convex section Pin Lever (: Locking type, -80: Non-locking type) To lock in the locking type, use a small screwdriver to push down on the manual override all the way and turn it clockwise 90 degrees. When locked, turning the manual override 90 degrees in a counterclockwise direction releases a spring on the manual override, returns it to the original position, and releases the lock. If the manual override is never turned, this type acts just like the non-locking type, like the valve energizing status as long as the manual override is pushed down, and returning to the rest position upon release. AC0V, AC0V Solenoid with LED indicator (surge suppression) Plug connector Lead wireac YellowAC0V WhiteAC0V Indication of polaritydc Contact Lead wireac YellowAC0V WhiteAC0V - C + Indication of polaritydc on the pilot valve Crimping of connecting lead wire and contact Cautions: 1. Do not apply megger between the lead wires.. While there is no danger with a DC solenoid of a short circuit due to the wrong polarity, the valve will not operate. 3. Leakage current inside the circuit could result in failure of the solenoid valve to return or in other erratic operation. Always use within the range of the allowable leakage current. If circuit conditions, etc., cause the leakage current to exceed the maximum allowable leakage current, consult us. 4. For double solenoid, avoid energizing both solenoids simultaneously. The valve could fall into a neutral state. To crimp lead wires into contacts, strip off 4mm of the insulation from the end of the lead wire, insert it into the contact, and bend down crimp holds. Be sure to avoid catching the insulation on the expose wire crimping section. Insulation crimp hold Expose wire crimping section Contact Hook Insulation Maximum outer diameter1.5 Expose wire 4mm Lead wire Applicable wire AWG430 Cautions:1. Do not pull hard on the lead wire.. Always use the dedicated tool for crimping of connecting lead wire and contact. Contact: Model 70631-MK Manufactured by Sumiko Tech, Inc. Crimping tool: Model F1 (for 70631 MK) Manufactured by Sumiko Tech, Inc. Attaching and removing contact and connector Insert the contact with lead wire into a plug connector hole until the contact hook catches and is secured to the plug connector. Confirm that the lead wire cannot be easily pulled out. To remove, insert a tool with a fine tip (such as a small screwdriver) into the rectangular hole on the bottom of the plug connector to push up on the hook, and then pull out the lead wire. Cautions: 1. While manual override operation is also possible on the pilot valve, be sure to always release the lock after completing the manual override operation. Moreover, always check on before valve operation to confirm that the lock on the pilot valve has been released.. The GF series are pilot type solenoid valves. As a result, the manual override cannot switch the main valve without supplying air from the P port. 3. Always release the lock on the locking type before commencing normal operation. 4. Do not attempt to operate the manual override with a pin or other object having an extremely fine tip. It could damage the manual override button. Cautions: 1. Do not pull hard on the lead wire. It could result in defective contacts, breaking wires, etc.. If the pin is bent, use a small screwdriver, etc., to gently straighten out the pin, and then complete the connection to the plug connector. 3. For crimping of connecting lead wire and contact, always use a dedicated crimping tool. If a crimping tool is required, consult us. 439

Valve function 3-port valves When using a 5-port valve as a 3-port valve In the GF, GF and GF18 series, plug one of the output ports (A or B) enabling to use as a normally closed (NC) or normally open (NO) 3-port valve. In this case, use the exhaust ports (R1 and R) in the opening status. This can also be applied to a double solenoid type 3-port valve. Plug position Switching type Single solenoid Plug the B port Normally closed (NC) 4A PlugB 14SA 5R1 1P 3R Plug the A port Normally open (NO) Plug4A B 14SA 5R1 1P 3R Split In the split type manifold, fitting splits to the P and R ports between each of the stations isolates the air path between the station installed with splits and stations with smaller numbered stations. Note, however, that a piping block must be placed on both ends. Split for the P port (Model : FZ-SP) Split for the R port (ModelFZ-SR) Split for the P and R ports (ModelFZ-SA) shows the valve size. GF, GF series Can supply two different kinds of pressure. Can isolate exhaust air. (prevents exhaust interference) Can supply two different kinds of pressure, and can isolate the exhaust air. (prevents exhaust interference) 14SA 14SA Double solenoid 4A PlugB 5R1 1P 3R Plug4A B 5R1 1P 3R SP:Split for the P port 1SB 1SB SR: Split for the R port GF18 series Manifold Attaching and removing valves To remove the valve body from the sub-base or manifold, loosen the valve mounting screws ( places), and lift up in the direction of the arrows (see diagram at right). For mounting, conduct the same procedure in reverse. The recommended tightening torques for the valve mounting screws are as shown below. SP: Split for the P port SR: Split for the R port Caution:Mounting splits requires the disassembly and re-assembly of the manifolds. See the disassembly diagram, unit adding procedure, and cautions found on p. 443~444. Precautions for using manifold Observe the following precautions when using the split type manifold (excluding the monoblock manifold) Illustration shows the GF series.split manifold Ncm {kgfcm} Series Recommended tightening torque GF 17.6 {1.8 GF 49.0 {5.0 GF18 49.0 {5.0 When using the direct piping type Avoid using valve at an operating frequency exceeding Hz, as such application can result in heat-relate breakdowns. When using the base piping type When plugs have been inserted into either or both of the A and B ports, avoid using valve at an operating frequency exceeding Hz, as such application can result in heat-related breakdowns. 440

Piping Fitting 1.Procedure for replacing the base piping type and the direct piping type Base piping and direct piping replacement can be done by replacing the plate with a fitting block or a female thread block. (see Figure 1). Except monoblock manifold F type, monoblock compact manifold A type and F type A port Fitting block B port Plate B port A port Plate Illustration shows the GF series. [Figure 1] Lead wire for common wiring Using the lead wire for common wiring, provided as additional parts, saves on wiring work. Lead wire for common wiring -PS, -PL, -PS3, -PL3 (set of pieces) G0-COM Cautions: 1. Firmly tighten the screws after completing a replacement.. Perform piping carefully in regards to the positions of each connection port (see Figures, 3). 3. Be careful about losing the gaskets while replacing plate and fitting block. DC plus side and AC common terminal wiring example Direct piping type For the GF, GF series For the GF18 series COM Crossover wire A port B port R port P port A port B port Note P port Note R port Connector Connector housing Illustration shows the GF series. Note: Be aware that the locations of the P and R ports are reversed from the positions in the GF, GF series. [Figure ] Base piping type Port locations of GF, GF, GF18 series are as shown in Figure 3. B port A port Illustration shows the GF series. [Figure 3] P port R port Polarity is for DC. Note: The diagram shows straight connector configuration.. Attaching fittings to female thread blocks When attaching fittings to female thread blocks, tighten within the tightening torques shown below. Thread size Tightening torque Ncm {kgfcm} Rc 1/8 686 {70} Rc 1/4 88 {90} For M5, tighten at the torques recommended for the fittings. 3.Attaching fittings to piping blocksgf18z(g)-pm To attach fittings to the female thread type piping block of the GF18 series, remove the piping block section (the triangular-shaped block section), apply a spanner to the metallic sections of both the P and R ports to fix them in place, and then thread in the fittings. The tightening torque for the mountings (two M3 screws) on the piping block section after the fittings have been attached should be 49.0 Ncm {5.0kgfcm}. 441

Precautions for use of individual air supply and exhaust spacers In valve specification T1, mounting an individual air supply or exhaust spacer on the manifold allows for isolating air supply or exhaust. Note that when spacers are used, the effective area is reduced by about 30%. If mounting additional spacers to an existing unit, observe the following items. Spacer mounting procedure (Valve specification T1 only) qloosen the valve mounting screws for the installation of individual air supply or exhaust spacer, and remove the valve. wattach the gaskets and exhaust valve provided with the individual air supply or exhaust spacer, use the mounting screws provided to mount the valve on the manifold. (See Figs. 4 and 5) For the recommended torque of the valve mounting screws, see p. 440. Remark: If attach fittings to the GF spacer, use the recommended fittings shown below. TSH4-M5M, TSH4-M5, TSH6-M5M, TS4-M50, TS4-M5M Caution: Locations where the spacers are mounted make the valve height higher by the height of the spacer. (See dimensions at right) Mounting screw Muffler for individual exhaust spacer A muffler for the individual exhaust spacer is available. For the outward appearance diagrams, see p.47, 484, and 495. Dimensions M50.8 9 Individual exhaust spacer FZ-N (For GF series) Mass 7g 58.5 Valve side Manifold side Muffler for individual exhaust spacer FZ-N (For GF series) Mass 6g 9.46, 8 90.5 Exhaust valve Gasket.8 Fitting6, 8 Individual air supply or exhaust spacer 13 Figure 4 F18Z-N (For GF18 series) Mass 41g Fitting8, 9.48 17.5 3.5 Cover Color: light blue GF, series (Illustration shows the split manifold non plug-in type) 18.8 18 13 Mounting screw Gasket Exhaust valve Individual air supply or exhaust spacer Figure 5 44 GF18 series (Illustration shows the split manifold non-plug-in type)

GF, Series Disassembly Diagram of Split Manifold Non-Plug-in Type Figure 1 Fixing screw End block Disassembly example: For GF series Piping block assembly Release lever Note: The GF series has the same basic construction. Valve base assembly End block Manifold Unit Adding Procedure (GF, GF Series Non-Plug-in Type) Adding valve base unit Use the valve base assembly to add units. qloosen the fixing screw on the end block until the end block can slide (see Figure 1). Note:For the G series, loosen the fixing screws on both left and right end blocks (three screws in each). wpress the release lever on the valve base assembly where the new unit is to be added, and disconnect the link between the bases. emount the valve base assembly to be added on the DIN rail shown in Figure. rreturn the release lever of the valve base assembly disassembled in Step w to its original position, as shown in Figure 3. In addition, set the release lever for the valve assembly being added to the same position, then press the valve bases together until they connect and click into place. tpress the bases together from both sides to ensure that there is no clearance between them, and then tighten the fixed screws on the end block, and fix the units in place on the DIN rail (see Figure 5). Tightening torque : 98Ncm {kgfcm} Notes: 1. Always follow the steps shown in Figure 4 when tightening the end block fixing screws for the GF series.. Confirm that the DIN rail mounting bracket's hooks are securely attached to the DIN rail. (see Figure 5). [Caution] Always cut off the power and air supply before working. In addition, always confirm that air has been completely exhausted from the manifold. Be careful not to get caught or lose the gaskets. Before supplying air to the manifold, always confirm that the bases are connected, the end block fixing screws are tightened, etc. Supplying air when either of the end blocks is not securely fixed on the DIN rail could result in air leaks or in separated manifold bases. When there are large number of valves simultaneously supplying air to the secondary side, or when there is a large number of valve units, we recommend to use two sources of air supply and exhaust (on each side). Note that adding units to the piping block assembly is performed in the same way as adding units to the valve base assembly. Figure Figure 3 Pressing down lightly on the release lever will return the lever to its original position. Figure 5 Fixing the end block in place Tighten the screw with the L-shaped hook pushed in. DIN rail Use hooks on both sides to fix the DIN rail in place. First let the hook catch on this side, and then press down on the base to fit it into the DIN rail. Figure 4Steps for tightening screws (for GF series only) 3 1 4 5 6 Always tighten the middle fixing screw of each end block first. Tightening torque: 98Ncm {kgfcm} Removing the end block from the DIN rail w q For mounting, follow in reverse the steps taken for removal. Caution: The new end block for the GF series does not include an L-shaped hook. To remove the end block from the DIN rail, loosen the end block fixing screws, and lift it off. The switch to the new type will commence in October 00 443

GF18 Series Disassembly Diagram of Split Manifold Non-Plug-in Type Figure 1 Connecting bolt End block Piping block assembly Valve base assembly Connecting rod End block Manifold Unit Adding Procedure (GF18 Series Non-Plug-in Type) Adding valve base unit Use the valve base assembly and connecting rods to add valve base units. q Remove the connecting bolts on the end block, and separate the end block from the manifold (see Figure 1). w Install the connecting rods to be added, open up spaces where the units are being added, attach gaskets into the valve base assemblies being added, and fit the units on the connecting rods. At this time, securely mount so that no clearance is left between the added valve base assembly and the upper surface of the connecting rods. e Fit gaskets into the end blocks removed in Step q, and retighten the connecting bolts. At this time, use a hexagonal bar spanner to hold the connecting bolts on the opposite side in place so as to prevent the bolts from slipping while tightening them into place. Tightening torque: 147Ncm {kgfcm} [Cautions] Always cut off the power and air supply before working. In addition, always confirm that air has been completely exhausted from the manifold. Be careful not to get caught or lose the gaskets. Before supplying air to the manifold, always confirm that the bases are connected, the end block connecting bolts on both sides are securely tightened, etc. Supplying air when either of the end blocks is not securely fixed in place could result in air leaks or in separated manifold bases. When there are large number of valves simultaneously supplying air to the secondary side, or when there is a large number of valve units, we recommend to use two sources of air supply and exhaust (on each side). Note that adding units to the piping block assembly is performed in the same way as adding units to the valve base assembly. 444

Operating Principle and Symbol 5-port, -position (De-energized) Single solenoid GFT1-A1-PS 14SA (De-energized condition after energizing solenoid SB) Double solenoid 14SA GFT-A1-PS 4A B 5R1 1P 3R 4A B 5R1 1P 3R 1SB Plunger Column Adapter End cover Note 5-port, 3-position All port block 4A B Flapper Pilot valve body Piston Lip seal PR PExternal pilot Note 1 5R1 4A 1P B 3R Valve body Stem Notes: 1. For external pilot type. Not available in external pilot type 14SA 5R1 1P 3R Note PR P Note 1 5R1 4A 1P B 3R (Both SA and SB are de-energized) ABR connection 14SA GFT3-A1-PS GFT4-A1-PS GFT5-A1-PS 4A B 5R1 1P 3R Major Parts and Materials Parts Materials Valve body Aluminum die-cast Pilot valve body Plastic Stem Aluminum alloy Lip seal Synthetic rubber Flapper Valve Plunger Magnetic stainless Column Piston Plastic Adapter End cover Monoblock type Aluminum alloy (anodized) Split type Plastic Manifold Block-off plate Steel (nickel plated) Seal Synthetic rubber Body PAB connection 14SA 4A B 5R1 1P 3R 1SB 1SB 1SB Note PR P Note 1 5R1 4A 1P B 3R Note PR P Note 1 5R1 4A 1P B 3R Note PR P Note 1 5R1 4A 1P B 3R Notes1. For external pilot type. Not available in external pilot type 445

446

GF Series Order Code GF The solenoid valves GF series order codes are classified into the following 6 categories. For details on order codes, see the designated pages. T: Single valve unit Koganei solenoid valves GFseries Valve size :mm width (Effective area 5mm ) :mm width (Effective areamm ) 18:18mm width (Effective area18mm ) MA: Monoblock manifold A type (base piping type) p. 448 p. 450 MAC: Monoblock compact manifold A type (base piping type) MF: Monoblock manifold F type (direct piping type) p. 45 p. 454 MFC: Monoblock compact manifold F type (direct piping type) p. 456 MN: Split manifold non-plug-in type p. 458 447

Single Valve Unit Order Code Valve specification Operation method Valve type Wiring -position (single solenoid) Internal pilot type (locking type) Without input/ output block With output port female thread block Grommet type Lead wire length 300mm 4A B 4A B T1 5R1 1P 3R -position (double solenoid) 5R1 1P 3R G External pilot type (for positive pressure) V External pilot type (for vacuum) : This is a vacuum valve. (non-locking type) A type with plate on output section -FM GFM50.8 GFRc1/8 GF18Rc1/4 With output port female thread block With input port female thread block Lead wire length 300mm T -80 -A1 -PS Valve size mm width Effective area 5mm GF mm width Effective area mm GF 18mm width Effective area 18mm 3-position (all port block) 4A B 4A B T3 T4 5R1 1P 3R 3-position (ABR connection) 4A B T5 5R1 1P 3R 3-position (PAB connection) 5R1 1P 3R A type with sub-base -A Output port GFRc1/8 GFRc1/8 GF18Rc1/4 With output port fitting block -FJ5 GF4 GF6 GF188 With output port fitting block L type plug connector -F4 Lead wire length 300mm Output port GFM50.8 GFRc1/8 GF18Rc1/4 -PL With output port fitting block With input port female thread block Lead wire length 3000mm Output port GF4 GF6 GF188 -F5 With output port fitting block With input port female thread block -F6 -PS3 L type plug connector Lead wire length 3000 mm -PL3 GF18 -FJ6 GF6 GF8 GF18 Output port GF6 GF8 GF18 Valve size Valve specification Operation method Valve type Wiring Voltage GF GF GF18 T1 T T3 T4 Note 3 T5 Note 3 G V -80 Note 1 -A1 Note 1 -A -FJ5 Note 1 -FJ6 Note 1 -FM Note 1 -F4 Note -F5 Note -F6 Note -PS -PL -PS3 -PL3 DC4V DC1V AC0V AC0V Note 4 Notes: 1. Two mounting screws for the manifold are included.. The units with input port female thread block can respond only to the internal pilot type valve in the operation method. 3. Not available in the vacuum valve. 4. For AC1V1V or AC V40V specifications, consult us. 448

Additional Parts Order Code for Single Valve Unit For internal pilot F Z - Valve size mm width mm width 1818mm width Parts content 1 Mounting bracket (mounting bracket, mounting screws) Note 1 5 Sub-base (sub-base body, gasket, exhaust valve) Note P Plate (plate, gasket, mounting screws) M Female thread block (female thread block, gasket, mounting screws) MP P port female thread block (P port female thread block, gasket) Note GS1 Gasket (gasket, exhaust valve) Note 3 Notes 1. Cannot be mounted on any but valve specification T1.. Valve mounting screws are not included. 3. Note that this is different from gasket GS used for the split manifold. For external pilot F Z - Sub-base for external pilot F ZG - 5 Valve size mm width mm width 1818mm width Parts content P Plate (plate, gasket, mounting screws) M Female thread block (female thread block, gasket, mounting screws) GS1 Gasket (gasket, exhaust valve) Note Note : Note that this is different from gasket GS used for the split manifold. Valve size mm width mm width 1818mm width Fitting block (for both internal pilot and external pilot) GF Z - Valve size mm width mm width 1818mm width Parts content J5: Fitting block GF:4, GF:6, GF18:8 (fitting block, gasket, two mounting screws) J6: Fitting block GF:6, GF:8, GF18: (fitting block, gasket, two mounting screws) Exhaust valve 5Sub-base GS1Gasket MPP port female thread block PPlate MFemale thread block JFitting block Illustration shows the GF series. 1Mounting bracket 449

Monoblock Manifold A Type (Base Piping Type) Order Code Operation method Wiring Left side Internal pilot type Note3 Grommet type Lead wire length 300mm Lead wire length 300mm L type plug connector Lead wire length 300mm G Right side External pilot type Note 4 (for positive pressure) -PS -PL Manifold output specification With fitting block V External pilot type Note 4 (for vacuum) :This is a vacuum valve. Note Cannot be combined with the positive pressure valve for mounting. Lead wire length 3000mm -PS3 L type plug connector Lead wire length 3000 mm -PL3 J Valve type Manifold fitting specification With female thread block Valve specification With plate (base piping type) M GF: M50.8 GF: Rc1/8 GF18: Rc1/4 T1: -position, single solenoid T: -position, double solenoid T3: 3-position, all port block T4: 3-position, ABR connection Note 5 T5: 3-position, PAB connection Note 5 -A1 -J5 Manifold side output port fitting GF4 GF6 GF188 -J6 Manifold side output port fitting GF6 GF8 GF18 Valve size Pilot specification (locking type) Individual air supply and exhaust spacer Note 7 GF mm width Effective area 5mm GF mm width Effective area mm GF18 18mm width Effective area 18mm Internal pilot manifold G External pilot manifold Note: Valves of different sizes can not be combined together for mounting. (non-locking type) -80 Without spacer -NPM Individual air supply spacer (with M5 female thread for GF) -NP6 Individual air supply spacer (with 6 fitting for GF) -NP8 Individual air supply spacer (with 8 fitting for GF and GF18) -NP0 Individual air supply spacer (with fitting for GF18) -NRM Individual exhaust spacer (with M5 female thread for GF) -NR6 Individual exhaust spacer (with 6 fitting for GF) -NR8 Individual exhaust spacer (with 8 fitting for GF and GF18) -NR0 Individual exhaust spacer (with fitting for GF18) For details, see p. 44. Valve size Number of units Manifold output specification Pilot specification Station Valve size Valve specification Operation method Manual override Valve type Wiring Manifold fitting specification Individual air supply and exhaust spacer Voltage Manifold model Mounting valve type GFM GFM GF18M A J M G G stn. stn. Note 1 stn. stn. Note 1 GF GF GF18 GF GF GF18 T1 T T3 T1 T T3 T4 Note 5 T5 Note 5 Note 3 G Note 4 V Note 4 T4 Note 5 T5 Note 5 Note 3 G Note 4 V Note 4-80 BP (for block-off plate) -80 -A1 Note -PS -PL -PS3 -PL3 -J5 -A1 Note -PS -PS3 -PL -PL3 BP (for block-off plate) -J6 Note 6 Note 7 -NPM -NRM -NP6 -NR6 -NP8 -NR8 -NP0 -NR0 Note 7 -NPM -NRM -NP6 -NR6 -NP8 -NR8 -NP0 -NR0 DC4V DC1V AC0V AC0V Note 8 DC4V DC1V AC0V AC0V Notes: 1. Valve mounting position from the left, with the solenoid on top and the A and B port in the front.. Always enter -A1. 3. Cannot be mounted on the external pilot manifold. 4. Cannot be mounted on the internal pilot manifold. In addition, G and V can not be combined mounting on the same manifold. 5. Not available in the vacuum valve. 6. To select the fitting on the manifold, always enter -J5 or -J6 after the valve or block-off plate code. 7. Individual air supply and exhaust spacers cannot be mounted on any but valve specification T1. 8. For AC1V1V or AC V40V specifications, consult us. 450

Monoblock Manifold A Type Additional Parts Order Code Gasket (gasket, exhaust valve) F GF Z - GS1 Valve size mm width mm width 1818mm width Block-off plate (block-off plate, mounting screws) BP Individual air supply and exhaust spacer F Z - Valve size mm width mm width 1818mm width For details, see p.44. (spacer, gasket, exhaust valve, mounting screws) Specification NPM Individual air supply spacer (with M5 female thread for GF) NP6 Individual air supply spacer (with 6 fitting for GF) NP8 Individual air supply spacer (with 8 fitting for GF and GF18) NP0 Individual air supply spacer (with fitting for GF18) NRM Individual exhaust spacer (with M5 female thread for GF) NR6 Individual exhaust spacer (with 6 fitting for GF) NR8 Individual exhaust spacer (with 8 fitting for GF and GF18) NR0 Individual exhaust spacer (with fitting for GF18) Valve size mm width mm width 1818mm width GS1Gasket BPBlock-off plate Lead wire for common wiring G0-COM For -PS, -PL, -PS3, -PL3 (set of pieces) Muffler KM - J Fitting size 6 Outer diameter 6 (for individual exhaust spacer) 8 Outer diameter 8 (for individual exhaust spacer) :Outer diameter (for individual exhaust spacer) (Sales unit: set of pieces) Exhaust valve Illustration shows the GF series. For external pilot Manifold Order Code Example (6 units of GF series) GFM6AJ stn.1 GFT1-A1-PS-J5 DC4V stn.35 GFT-A1-PS-J6 DC4V stn.6 GFBP-J5 Note: This order code example has no relationship to the above illustration. Order Code Precautions Manifold output specification Select with either a fitting block or a female thread block. For repairs and replacements, purchase from the additional parts for single valve unit from GFZ-J (fitting block) or FZ-M (female thread block) on p.449. Orders for valves only Place order by Single Valve Unit Order Code on p.448. Note, however, that valve type are limited to -A1 (with plate) only. The -J5 and -J6 codes are for ordering with manifolds. 451

Monoblock Compact Manifold A Type (Base Piping Type) Order Code Valve type Wiring Left side With plate (base piping type) Grommet type Lead wire length 300mm Lead wire length 300mm L type plug connector Lead wire length 300mm Right side -A1 -PS -PL Manifold output specification Lead wire length 3000mm L type plug connector Lead wire length 3000 mm Fitting specification (locking type) -PS3 -PL3 J Female thread specification M GF: M50.8 GF: Rc1/8 (non-locking type) -80 Manifold fitting specification Manifold output port fitting GF4 GF6 -J5 -J6 Manifold output port fitting GF6 GF8 Valve size GF mm width Effective area 5mm GF mm width Effective area mm Valve specification T1: -position, single solenoid T: -position, double solenoid T3: 3-position, all port block T4: 3-position, ABR connection T5: 3-position, PAB connection Individual air supply and exhaust spacer Note 7 Without spacer -NPM Individual air supply spacer (with M5 female thread for GF) -NP6 Individual air supply spacer (with 6 fitting for GF) -NP8 Individual air supply spacer (with 8 fitting for GF) -NRM Individual exhaust spacer (with M5 female thread for GF) -NR6 Individual exhaust spacer (with 6 fitting for GF) -NR8 Individual exhaust spacer (with 8 fitting for GF) For details, see p. 44. Note: Valves of different sizes can not be combined together for mounting. Valve size Number of units Manifold output specification Station Valve size Valve specification Manual override Valve type Wiring Manifold fitting specification Individual air supply and exhaust spacer Voltage Manifold model Mounting valve type GFM GFM AC J M stn. stn. Note 1 stn. stn. Note 1 GF GF GF GF T1 T4 T T5 T3 T1 T T3 T4 T5-80 -A1 -J5 Note -PS -PS3 -PL -PL3 BP (for block-off plate) -80 -A1 Note -PS -PS3 -PL -PL3 -J6 Note 3 BP (for block-off plate) -NPM -NP6 -NP8 -NPM -NP6 -NP8 Note 4 -NRM -NR6 -NR8 Note 4 -NRM -NR6 -NR8 DC4V DC1V AC0V AC0V Note 5 DC4V DC1V AC0V AC0V Note 5 Notes: 1. Valve mounting position from the left, with the solenoid on top and the A and B port in the front.. Always enter -A1. 3. To select the fitting on the manifold side, always enter -J5 or -J6 after the valve or block-off plate code. 4. Individual air supply and exhaust spacers cannot be mounted on any but valve specification T1. 5. For AC1V1V or AC V40V specifications, consult us. 45

Additional Parts Order Code for Monoblock Compact Manifold A Type Gasket (gasket, exhaust valve) F Z - GS1 Individual air supply and exhaust spacer F Z - (spacer, gasket, exhaust valve, mounting screws) Valve size mm width mm width Valve size mm width mm width Specification NPM Individual air supply spacer (with M5 female thread for GF) NP6 Individual air supply spacer (with 6 fitting for GF) NP8 Individual air supply spacer (with 8 fitting for GF) NRM Individual exhaust spacer (with M5 female thread for GF) NR6 Individual exhaust spacer (with 6 fitting for GF) NR8 Individual exhaust spacer (with 8 fitting for GF) Block-off plate (block-off plate, mounting screws) GF BP Note : Individual air supply and exhaust spacers cannot be mounted on any but valve specification T1. For details, see p.44. Valve size mm width mm width GS1Gasket Lead wire for common wiring G0-COM For -PS, -PL, -PS3, -PL3 (set of pieces) BPBlock-off plate Muffler KM - J Fitting size 6 Outer diameter 6 (for individual exhaust spacer) 8 Outer diameter 8 (for individual exhaust spacer) (Sales unit: set of pieces) Exhaust valve Illustration shows the GF series. Manifold Order Code Example (6 units of GF series) GFM6ACJ stn.1 GFT1-A1-PS-J5 DC4V stn.35 GFT-A1-PS-J6 DC4V stn.6 GFBP-J5 Note: This order code example has no relationship to the above illustration. Order Code Precaution Manifold output specification Select with either fitting specification or female thread specification. Orders for valves only Place order by Single Valve Unit Order Code on p.448. Note, however, that valve type are limited to -A1 (with plate) only. The -J5 and -J6 are for ordering with manifolds. 453

Monoblock Manifold F type (Direct Piping Type) Order Code Valve type Wiring Individual air supply and exhaust spacer Note 3 Left side Valve size mm width Effective area 5mm Right side (locking type) With fitting block -FJ5 Output port fitting GF4 GF6 GF188 With fitting block -FJ6 Grommet type Lead wire length 300mm Lead wire length 300mm -PS Lead wire length 3000mm Without spacer -NPM Individual air supply spacer (with M5 female thread for GF) -NP6 Individual air supply spacer (with 6 fitting for GF) -NP8 Individual air supply spacer (with 8 fitting for GF and GF18) -NP0 Individual air supply spacer (with fitting for GF18) -NRM Individual exhaust spacer (with M5 female thread for GF) -NR6 Individual exhaust spacer (with 6 fitting for GF) -NR8 Individual exhaust spacer (with 8 fitting for GF and GF18) -NR0 Individual exhaust spacer (with fitting for GF18) For details, see p. 44. GF Output port fitting GF6 GF8 GF18 -PS3 mm width Effective area mm (non-locking type) With female thread block L type plug connector Lead wire length 300mm GF 18mm width Effective area 18mm -80 -FM Output port female thread GFM50.8 GFRc1/8 GF18Rc1/4 -PL L type plug connector Lead wire length 3000mm GF18 -PL3 ote: Valves of different sizes can not be combined together for mounting. Valve size Number of units Manifold model Station Valve size Valve specification Manual Valve type Wiring Individual air supply override and exhaust spacer Voltage Mounting valve type GFM GFM GF18M F Note stn. stn. Note 1 GF GF GF18 T1 : -position single solenoid T : -position double solenoid T3 : 3-position all port block T4 : 3-position ABR connection T5 : 3-position PAB connection -80 -FJ5 -FJ6 -FM -PS -PL -PS3 -PL3 Note 3 -NPM -NP6 -NP8 -NP0 -NRM -NR6 -NR8 -NR0 DC4V DC1V AC0V AC0V Note 4 BP (for block-off plate) Notes: 1. Valve mounting position from the left, with the solenoid on top and the A and B port in the front.. The external pilot type valve cannot be mounted on the F type manifold. 3. Individual air supply and exhaust spacers cannot be mounted on any but valve specification T1. 4. For AC1V1V or AC V40V specifications, consult us. 454

Additional Parts Order Code for Monoblock Manifold F Type Gasket (gasket, exhaust valve) F GF Valve size mm width mm width 1818mm width Z - GS1 Block-off plate (block-off plate, mounting screws) BP Individual air supply and exhaust spacer F Z - Valve size mm width mm width 1818mm width For details, see p.44. (spacer, gasket, exhaust valve, mounting screws) Specification NPM Individual air supply spacer (with M5 female thread for GF) NP6 Individual air supply spacer (with 6 fitting for GF) NP8 Individual air supply spacer (with 8 fitting for GF and GF18) NP0 Individual air supply spacer (with fitting for GF18) NRM Individual exhaust spacer (with M5 female thread for GF) NR6 Individual exhaust spacer (with 6 fitting for GF) NR8 Individual exhaust spacer (with 8 fitting for GF and GF18) NR0 Individual exhaust spacer (with fitting for GF18) Valve size mm width mm width 1818mm width GS1Gasket Lead wire for common wiring G0-COM For -PS, -PL, -PS3, -PL3 (set of pieces) BPBlock-off plate Muffler KM - J Fitting size 6 Outer diameter 6 (for individual exhaust spacer) 8 Outer diameter 8 (for individual exhaust spacer) Outer diameter (for individual exhaust spacer) (Sales unit: set of pieces) Exhaust valve Illustration shows the GF series. Manifold Order Code Example (4 units of GF series) GFM4F stn.1 GFT1-FJ5-PS DC4V stn.3 GFT-FJ6-PS DC4V stn.4 GFBP Note: This order code example has no relationship to the above illustration. Order Code Precautions Orders for valves only Place order by Single Valve Unit Order Code on p.448. Note, however, that valve type selection is limited to -FJ5, -FJ6, -FM. 455

Monoblock Compact Manifold F type (Direct Piping Type) Order Code Valve type Wiring Individual air supply and exhaust spacer Note 3 Left side Right side With fitting block -FJ5 Output port fitting GF4 GF6 Grommet type Lead wire length 300mm Lead wire length 300mm Without spacer -NPM Individual air supply spacer (with M5 female thread for GF) -NP6 Individual air supply spacer (with 6 fitting for GF) -NP8 Individual air supply spacer (with 8 fitting for GF) -NRM Individual exhaust spacer (with M5 female thread for GF) -NR6 Individual exhaust spacer (with 6 fitting for GF) -NR8 Individual exhaust spacer (with 8 fitting for GF) For details, see p. 44. Valve size With fitting block -PS mm width Effective area 5mm (locking type) -FJ6 Lead wire length 3000mm GF Output port fitting GF6 GF8 -PS 3 mm width Effective area mm (non-locking type) With female thread block L type plug connector Lead wire length 300mm GF -80 -FM Output port female thread GFM50.8 GFRc1/8 -PL L type plug connector Lead wire length 3000mm -PL 3 ote: Valves of different sizes can not be combined together for mounting. Valve size Number of units Manifold model Station Valve size Valve specification Manual Valve type Wiring Individual air supply override and exhaust spacer Voltage Mounting valve type GFM GFM FC Note stn. stn. Note 1 GF GF T1 : -position single solenoid T : -position double solenoid T3 : 3-position all port block T4 : 3-position ABR connection T5 : 3-position PAB connection -80 -FJ5 -FJ6 -FM -PS -PL -PS3 -PL3 Note 3 -NPM -NP6 -NP8 -NRM -NR6 -NR8 DC4V DC1V AC0V AC0V Note 4 BP (for block-off plate) Notes: 1. Valve mounting position from the left, with the solenoid on top and the A and B port in the front.. The external pilot type valve cannot be mounted on the F type manifold. 3. Individual air supply and exhaust spacers cannot be mounted on any but valve specification T1. 4. For AC1V1V or AC V40V specifications, consult us. 456

Monoblock Compact Manifold F type Additional Parts Order Code Gasket (gasket, exhaust valve) F GF Valve size mm width mm width Z - GS1 Block-off plate (block-off plate, mounting screws) BP Valve size mm width mm width Individual air supply and exhaust spacer F Z - Valve size mm width mm width (spacer, gasket, exhaust valve, mounting screws) Specification NPM Individual air supply spacer (with M5 female thread for GF) NP6 Individual air supply spacer (with 6 fitting for GF) NP8 Individual air supply spacer (with 8 fitting for GF) NRM Individual exhaust spacer (with M5 female thread for GF) NR6 Individual exhaust spacer (with 6 fitting for GF) NR8 Individual exhaust spacer (with 8 fitting for GF) Note : Individual air supply and exhaust spacers cannot be mounted on any but valve specification T1. For details, see p.44. GS1Gasket Lead wire for common wiring G0-COM For -PS, -PL, -PS3, -PL3 (set of pieces) BPBlock-off plate Muffler KM - J Fitting size 6 Outer diameter 6 (for individual exhaust spacer) 8 Outer diameter 8 (for individual exhaust spacer) (Sales unit: set of pieces) Illustration shows the GF series. Manifold Order Code Example (4 units of GF series) GFM4FC stn.1 GFT1-FJ5-PS DC4V stn.3 GFT-FJ6-PS DC4V stn.4 GFBP Note: This order code example has no relationship to the above illustration. Order Code Precautions Orders for valves only Place order by Single Valve Unit Order Code on p.448 Note, however, that valve type selection is limited to -FJ5, -FJ6, -FM. 457

Split Manifold Non-Plug-in Type Order Code Manifold output specification Valve type Wiring With fitting block (base piping type) Left side (locking type) With plate (base piping type) Grommet type Lead wire length 300mm Lead wire length 300mm Lead wire length 3000mm J -A1 -PS -PS3 Output port fitting With female thread block (base piping type) Right side Piping block specification (non-locking type) With fitting block (direct piping type) L type plug connector Lead wire length 300mm L type plug connector Lead wire length 3000mm M Output port female thread GFM50.8 GFRc1/8 GF18Rc1/4 With plate (direct piping type) Valve size GFM mm width Effective area GFM mm width Effective area mm GF18M 18mm width Effective area -JR : With fitting on right side -JL : With fitting on left side -JD : With fittings on both sides P, R port fitting GF : 8 GF : GF18 : 1 -MR: With female thread on right side -ML: With female thread on left side -MD: With female thread on both sides P, R port female thread GF : Rc1/4 GF : Rc1/4 GF18 : Rc3/8 Pilot specification Internal pilot manifold G External pilot manifold Operation method Valve specification T1: -position, single solenoid T: -position, double solenoid T3: 3-position, all port block T4: 3-position, ABR connection T5: 3-position, PAB connection -80 Internal pilot type Note 4 G External pilot type Note 5 (for positive pressure) No vacuum valve can be mounted. Note: Valves of different sizes cannot be combined together for mounting. -FJ5 Output port fitting GF4 GF6 GF188 With fitting block (direct piping type) -FJ6 Output port fitting GF6 GF8 GF18 With female thread block (direct piping type) -FM Output port female thread GFM50.8 GFRc1/8 GF18Rc1/4 Manifold fitting specification -J5 Manifold side output port fitting GF4 GF6 GF188 -PL -J6 Manifold side output port fitting GF6 GF8 GF18 Split -PL3 Individual air supply and exhaust spacer Note 7 Without spacer -NPM Individual air supply spacer (with M5 female thread for GF) -NP6 Individual air supply spacer (with 6 fitting for GF) -NP8 Individual air supply spacer (with 8 fitting for GFand GF18) -NP0 Individual air supply spacer (with fitting for GF18) -NRM Individual exhaust spacer (with M5 female thread for GF) -NR6 Individual exhaust spacer (with 6 fitting for GF) -NR8 Individual exhaust spacer (with 8 fitting for GF and GF18) -NR0 Individual exhaust spacer (with fitting for GF18) For details, see p. 44. Without split -SP For P port Note 3 -SR For R port Note 3 -SA For both P and R ports Note 3 Valve size Number of units Manifold output specification Pilot specification Piping block specification Station Valve size Valve specification Operation method Manual overrid Valve type Wiring Manifold fitting specification Individual air supply and exhaust spacer Split Voltage Manifold model Mounting valve type Base piping type GFM GFM GF18M N J M G G -JR -MR -JL -ML -JD -MD -JR -MR -JL -ML -JD -MD stn. stn. Note 1 stn. stn. Note 1 GF GF GF18 GF GF GF18 T1 T4 T T5 Note 4 T3 G Note 5-80 -A1 Note BPN(block-off plate) T1 T4 T T5 Note 4 T3 G Note 5-80 -A1 Note -PS -PL -PS3 -PL3 -PS -PL -PS3 -PL3 BPN(block-off plate) -J5 -J6 Note 6 -NPM -NP6 -NP8 -NP0 -NPM -NP6 -NP8 -NP0 Note 7 -NRM -NR6 -NR8 -NR0 Note 7 -NRM -NR6 -NR8 -NR0 -SP Note 3 -SR Note 3 -SA Note 3 -SP Note 3 -SR Note 3 -SA Note 3 DC4V DC1V AC0V AC0V Note 8 DC4V DC1V AC0V AC0V Note 8 Direct piping type G -JR -MR -JL -ML -JD -MD stn. stn. Note 1 GF GF GF18 T1 T4 T T5 Note 4 T3 G Note 5-80 -PS -PL -PS3 -PL3 Notes: 1. Valve mounting position from the left, with the solenoid on top and the A and B port in the front.. When selecting J or M (base piping type) for the manifold output specification, always enter -A1 (with plate) for the valve type. 3. Split can be mounted as long as piping blocks are attached to both sides. In addition, the number of splits that can be mounted on one manifold is limited to one location (one station). Splits are installed at time of delivery in the place between the designated station and the station to its left (the side with the smaller station number). 4. Cannot be mounted on the external pilot manifold. 5. Cannot be mounted on the internal pilot manifold. 6. To select the fitting on the manifold, always enter -J5 or -J6 after the valve or block-off plate code. 7. Individual air supply and exhaust spacers cannot be mounted on any but valve specification T1. 8. For AC1V1V or AC V40V specifications, consult us. 458 -FJ5 -FJ6 -FM BPN(block-off plate) -NPM -NP6 -NP8 -NP0 Note 7 -NRM -NR6 -NR8 -NR0 -SP Note 3 -SR Note 3 -SA Note 3 DC4V DC1V AC0V AC0V Note 8

Additional Parts Order Code for Split Manifold Non-Plug-in Type Part for manifold F Z - Valve size mm width mm width 1818mm width GF Z - Valve size mm width mm width 1818mm width Piping block assembly GF Z - Valve size mm width mm width 1818mm width Parts content GS Gasket (gasket, exhaust valve) SP Split (for P port) SR Split (for R port) SA Split (for both P and R ports) Block-off plate (block-off plate, mounting screws) GF Valve base assembly (valve base, gasket, plug 1 ) Piping specification VJ5 Valve base fitting (GF:4, GF:6, GF18:8) VJ6 Valve base fitting (GF:6, GF:8, GF18:) VM Valve base female thread VP Valve base plate Pilot specification Internal pilot G External pilot (GF and GF only) 1No plug included for GF18. For GF18 covers both internal pilot and external pilot. Muffler Valve size mm width mm width 1818mm width KM - J BP N G0-COM For non-plug-in Pilot specification Internal pilot G External pilot Piping specification PJ Piping block fitting PMPiping block female thread Fitting size 6 Outer diameter 6 (for individual exhaust spacer) 8 Outer diameter8 (for GF or individual exhaust spacer) Outer diameter (for GF or individual exhaust spacer) 1 Outer diameter1 (for GF18) (Sales unit: set of pieces) Lead wire for common wiring For -PS, -PL, -PS3, -PL3 (set of pieces) Individual air supply and exhaust spacer F Z - Valve size mm width mm width 1818mm width For details, see p. 44. Piping block assembly End block (a set of left and right) F Z - E Valve size mm width mm width 1818mm width F18Z - - Exhaust valve (spacer, gasket, exhaust valve, mounting screws) Specification NPM Individual air supply spacer (with M5 female thread for GF) NP6 Individual air supply spacer (with 6 fitting for GF) NP8 Individual air supply spacer (with 8 fitting for GF and GF18) NP0 Individual air supply spacer (with fitting for GF18) NRM Individual exhaust spacer (with M5 female thread for GF) NR6 Individual exhaust spacer (with 6 fitting for GF) NR8 Individual exhaust spacer (with 8 fitting for GF and GF18) NR0 Individual exhaust spacer (with fitting for GF18) Pilot specification : Internal pilot G : External pilot (GF and GF only) Connecting rod (GF18 series only) Additional unit number 01 (RH is 04) For reduction of unit, consult us. Specification RVFor valve base RHFor piping base End block for the GF18 is for both internal pilot and external pilot. GSGasket BPNBlock-off plate SPSplit for the P port Note SRSplit for the R port Note NoteSplits for the GF 18 series differ in their outward appearance. Illustration shows the GF series. Manifold Order Code Example (4 units of GF series) GFM4NJ-JR stn.1 GFT1-A1-PS-J5 DC4V stn.3 GFT-A1-PS-J6 DC4V stn.4 GFBPN-J5 Note: This order code example has no relationship to the above illustration. Order Code Precautions Orders for valves only Place order by Single Valve Unit Order Code on p.448. Note, however, that, A, F4, F5, F6 cannot be selected as the valve type. 459

460

SOLENOID VALVES SERIES INDEX Specifications 46 Dimensions of Single Valve Unit 465 Dimensions of Monoblock Manifold 469 Dimensions of Monoblock Compact Manifold 470 Dimensions of Split Non-Plug-in Type 471 461

GF SERIES SPECIFICATIONS Specifications Basic Models and Valve Functions Basic model GFT1 Item GFT Number of positions positions Number of ports Valve function Single solenoid or double solenoid Remarks: For optional specifications and order code, see p.448459. 5 GFT3 GFT4 GFT5 3 positions All port block, ABR connection or PAB connection Specifications Item Basic model Solenoid Specifications GFT1 GFT GFT3 GFT4 GFT5 Media Operation method Internal pilot type Effective areacv Note 1 mm 50.8 4.50.5 Port size Note Lubrication Operating pressure Main valve 0..7MPa {7.1kgf/cm } range External pilot Proof pressure MPa {kgf/cm } Response time Note 4 DC1V, DC4V, 30 ms ONOFF AC0V, AC0V, 5 Maximum operating frequency Hz Minimum time to energize for self holding Note 5 ms 50 Operating temperature range (atmosphere and media) C 1373 {140.0} Shock resistance m/s {G} pilot valve axial direction 94. {30.0} 94. {30.0} Mounting direction GFT3G GFT1G GFT1V GFT4G GFTG GFTV GFT5G GFT3V Air External pilot type (for positive pressure) External pilot type (for vacuum) 50.8 4.50.5 50.8 4.50.5 M50.8, 4,6 fitting, Rc1/8 Not required 00.7MPa {07.1kgf/cm } Note 3 0..7MPa {7.1kgf/cm } Note 3 0.MPa0kPa {1.5kgf/cm 750.1mmHg} 0..7MPa {7.1kgf/cm } 1.05 {.7}, 30, 30, 5, 5 5 50 50 550 1373 {140.0} 1373 {140.0} pilot valve axial direction 94.{30.0 pilot valve axial direction 94. {30.0} 94. {30.0} 94. {30.0} Any Notes: 1. For details, see the effective area on p.463.. For details, see the port size on p.463. 3. When the main valve pressure is 0..7MPa, set the external pilot pressure to the main valve pressure or higher and to 0.7 MPa or less. 4. Values when air pressure is 0.5MPa. Values in brackets are for T. And the values for 3-position valves are those switching from the neutral position. For switching phase timing, add a maximum of 5 ms to the response time of AC specification. 5. For the double solenoid. Remark: Conversion to psi., 1Mpa=145psi., 1kgf/cm =14.psi., e.g. 0.Mpa=9psi. Item Rated voltage DC1V DC4V AC0V Note AC0V Note Operating voltage range V.813. 1.66.4 901 180 (1) (4) (0) (0) Rated frequency Hz 50 60 50 60 Current (When rated voltage is applied) Power consumption Allowable leakage current ma (r.m.s) ma 4 0.5W 1.0 1 0.5W 1.0 11 1.1VA 1.0 8 1.6VA 1.0 Insulation resistance M Min. 0 (value at DC500V megger) Wiring and lead wire length Color of lead wire Color of LED indicator Surge suppression (as standard) Grommet type: 300mm Red (+), Black ( ) Flywheel diode Plug connector type: 300mm,3000mm Yellow Red Bridge diode White Notes: 1. Since the AC types have built-in bridge diodes, the starting current value and energizing current value are virtually the same.. For long time continuous energizing of AC types, consult us. 3. Provide heat radiation measures to ensure that the ambient temperature (or when using a control box, the internal temperature of the box) always remains within the temperature range specifications. 46

Cylinder Operating Speed Flow Rate How to obtain cylinder speed Cylinder stroke Solenoid valve energized t 1 t t 3 Cylinder start Measurement conditions Air pressure: 0.5MPa {5.1kgf/cm } Piping (outer diameter inner diameterlength): 6400mm Fitting: Quick fittingts6-01 Load Load ratio Cylinder theoretical thrust () Load Cylinder stroke: 0mm 0.5MPa Cushioning impact Cylinder stop Time Maximum operating speed mm/s 10 Maximum operating speed Delay time 00 800 600 400 0 0 Delay time s 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0. 0.1 0 30 40 50 60 70 Load ratio % 30 40 50 60 70 Load ratio % 5 3 40 50 50 3,40 5 Note:Delay time may vary according to the cylinder stroke. MPa 0.7 Valve outlet pressure 0.6 0.5 0.4 0.3 0. 0.1 0 Supply pressure MPa 0.7 0.6 0.5 0.4 0.3 0. 0.1 0 0 300 400 500 Flow rater/minanr How to read the graph If supply pressure is 0.5MPa and flow rate is 40R/min (ANR), the valve outlet pressure becomes 0.4MPa. Port Size GF Series Single unit Manifold Basic model GFT1-A GFT-A GFT3-A GFT4-A GFT5-A GFT1-F4 GFT-F4 GFT3-F4 GFT4-F4 GFT5-F4 GFT1-F5 GFT-F5 GFT3-F5 GFT4-F5 GFT5-F5 Item/Piping specification With sub-base With female thread block With fitting block Monoblock type (with female thread block, female thread specification) Monoblock type (with fitting block, fitting specification) Split type with female thread block Split type with fitting block Effective AreaCv When using as a single unit mm Effective AreaCv 5.00.8 4.50.5 3.80.1 3.50. 3.50. PR M50.8 M50.8 M50.8 Valve model GFT1 GFT GFT3 GFT4 GFT5 GFT1 GFT GFT3 GFT4 GFT5 Manifold model Output port Female thread Output port 4 fitting 6 fitting P M50.8 M50.8 M50.8 M50.8 M50.8 When mounted on the manifold GFMF 4.50.5 4.50.5 3.50. 3.50. GFMFC 4.00. 4.00. 3.50. 3.50. A, B Rc 1/8 M50.8 4,6 M50.8 4,6 M50.8 4,6 GFMA 4.00. 4.00. 3.30.18 3.30.18 GFMAC 3.50. 3.50. 3.30.18 3.30.18 P, R Rc 1/8 M50.8 M50.8 Rc 1/8 Rc 1/8 Rc 1/4 8 mm GFMN 5.00.8 4.50.5 4.30.4 3.80.1 GFT1-F6 GFT-F6 GFT3-F6 GFT4-F6 GFT5-F6 3.50. 463

Mass Single Valve Unit Mass g Model Valve specification T1 T T3, T4, T5 GFT Output section None Input section None 33 49 51 GFT-A1 Output section With plate Input section None 36 5 54 GFT-A Output section With plate Input section With A type sub-base 5 11 13 GFT-FJ5 Output section With 4 fitting block Input section None 47 6 64 GFT-FJ6 Output section With 6 fitting block Input section None 49 65 67 GFT-FM Output section With female thread block Input section None 40 56 58 GFT-F4 Output section With female thread block Input section With female thread block 48 64 66 GFT-F5 Output section With 4 fitting block Input section With female thread block 54 70 7 GFT-F6 Output section With 6 fitting block Input section With female thread block 57 73 75 Block-off plate: 5.1g Monoblock Manifold Mass Monoblock manifold Mass calculation of each unit (n=number of units) Manifold A, B port output specification Monoblock manifold A type With female thread block (50n) -J5 with 4 fitting block (57n) -J6 with 6 fitting block (59n) Monoblock manifold F type (5n) Calculation example: GFM8AJ stn.1stn.8 GFT1-A1-PS-J5 DC4V (578)70(368)814g Additional mass 70 70 g Monoblock Compact Manifold Mass Monoblock compact manifold Mass calculation of each unit (n=number of units) Manifold A, B port output specification Monoblock compact manifold A type Monoblock compact manifold F type -J5 with 4 fitting specification -J6 with 6 fitting specification Calculation example: GFM8ACJ stn.1stn.8 GFT1-A1-PS-J5 DC4V (48)57(368)681g Additional mass 57 44 g Split Type Manifold Mass Split type manifold Mass calculation of each unitn=number of units Manifold A, B port output specification Base piping type With female thread block (5n) -J5 with 4 fitting block (3n) -J6 with 6 fitting block (34n) Direct piping type (1n) Calculation example: GFM8NJ-JR stn.1stn.8 GFT1-A1-PS-J5 DC4V (38)186(36888g Additional mass Piping block With female thread With fitting block 141 18 141 18 g End block 6 6 464

GF Series Dimensions of Single Valve Unit (Scale 1/3, Unit mm) GFT1-F5-PS With output port fitting block With input port female thread block -F5: (45.4), -F6: (47.) -F5: 36.9, -F6: 38.7 1 3338 GFT1F5 (300) 5 3-M50.8-3. (Mounting hole) 88. -Quick fitting (-F5:4) (-F6:6) 1.6 1.6 3 33 11.5 6.5-3. (Mounting hole) 1 1. 5 4 58 49.5 11.8 17.1 4 (A) port (B) port Values in brackets are for AC 0V specification. GFT-F5-PS With output port fitting block With input port female thread block -F5: (45.4), -F6: (47.) -F5: 36.9, -F6: 38.7 1 3338 GFTF5 5 (300) -Manual override 1.6 1.6 3-M50.8-3. (Mounting hole) 48.7 33 11.5 130.4 30. 70 5.9 5.9 65. -Quick fitting (-F5: 4) (-F6: 6) 4 (A) port (B) port Values in brackets are for AC 0V specification. GFT3-F5-PS GFT4-F5-PS GFT5-F5-PS With output port fitting block With input port female thread block 1.6 -F5: 36.9, -F6: 38.7 1 3338 3-M50.8-3. (Mounting hole) 33 56.7 11.5 (300) 138.4 78 - -Quick fitting (-F5:4) (-F6:6) 30. 1.6 5 -F5: (45.4), -F6: (47.) 5.9 5.9 73. 4 (A) port (B) port GFT3F5 Values in brackets are for AC 0V specification. 465

GF Series Dimensions of Single Valve Unit (Scale 1/3, Unit mm) GFT1-F4-PS With output port female thread block With input port female thread block (41.5) 46.5) 1 3338 (300) GFT1F4 5 3-M50.8-3. (Mounting hole) 88. -M50.8 1.6 1.6 3 33 11.5-3. (Mounting hole) 1 1. 5 4 58 49.5 11.8 17.1 4 (A) port (B) port Values in brackets are for AC 0V specification. GFT-F4-PS With output port female thread block With input port female thread block (41.5) 46.5) 3338 1 4 GFTF4 5 (300) -Manual override 3-M50.8-3. (Mounting hole) -M50.8 1.6 1.6 48.7 33 11.5 130.4 70 30. 65. 4 (A) port (B) port Values in brackets are for AC 0V specification. GFT3-F4-PS GFT4-F4-PS GFT5-F4-PS With output port female thread block With input port female thread block 3338 1 4 5 (41.5) (46.5) (300) -Manual override 3-M50.8-3. (Mounting hole) -M50.8 56.7 33 11.5 GFT3F4 138.4 78 5.9 5.9 30. 73. 1.6 1.6 4 (A) port (B) port 466 Values in brackets are for AC 0V specification.

GF Series Dimensions of Single Valve Unit (Scale 1/3, Unit mm) GFT1-A-PS GFT1A With A type sub-base (300) -Rc1/8-3. (Mounting hole) M50.8 3-Rc1/8 4 (A) 18.8 PR 1 (P) 5 (R1) (B) 3 (R) 5 1.4 50 44 58 88. 90. 11 11.5 7.5 14.5 4 4 3338 57.56.5 3 3 8 5.5 7.5 Values in brackets are for AC 0V specification. GFT-A-PS GFTA With A type sub-base - (300) -Rc1/8-3. (Mounting hole) M50.8 3-Rc1/8 1.4 4 (A) 50 44 18.8 70 130.4 PR 1 (P) 5 (R1) 11 11.5 (B) 7.5 14.5 4 4 3338 57.56.5 40. 3 3 8 5 30. 3 (R) 5 7.5.5 Values in brackets are for AC 0V specification. GFT3-A-PS GFT4-A-PS GFT5-A-PS With A type sub-base -Rc1/8 - -3. (Mounting hole) (300) M50.8 3-Rc1/8 4 (A) (B) 48. 30. 3 18.8 1.4 50 44 78 138.4 PR 1 (P) 5 (R1) 3 (R) 11 11 5.5 GFT3A 7.5 14.5 4 4 3338 57.56.5 3 8 5.5 7.5 Values in brackets are for AC 0V specification. 467

GF Series Dimensions of Single Valve Unit (Scale 1/3, Unit mm) External pilot specification GFT1G-A-PS With A type sub-base (300) M50.8 6-3. (Mounting hole) M50.8 3-Rc1/8 18.8.9 9.7 -Rc1/8 7.5 4 (A) (B) P.5 4 4 3338 57.56.5 50 44 3 3 8 5 58 88. 90. PR 5 (R1) 1 (P) 3 (R).5 11 11 7.5.5 5 Values in brackets are for AC 0V specification. Wiring G_SOL When mounting DC1V, DC4V, AC0V Grommet Solenoid with L type plug connector (-PL) (300) LED indicator 33 LED indicator R 44.1 11.1 A B.6.6 When mounting AC0V Grommet 38 300 Solenoid with L type plug connector (-PL) R 49.1 11.1 Solenoid with (-PS) 38 R Code Model GFT1 GFT GFT3, 4, 5 A 78.6 111. 1. B 77.6 9. 117. R(lead wire length) Standard: 300 -P3: 3000 Remarks Length to the end of the valve Total length to the end of the opposite solenoid 468

GF Series Dimensions of Monoblock Manifold A Type and F Type (Scale 1/3, Unit mm) GFM Number of units A Pilot specification (base piping type) Monoblock manifold A type With manifold output port fitting block J M GFMAJ -M50.8 (Both sides) -M50.8 (Both sides) (For external pilot specification) GFM 50 41 4.5 6-Rc1/8 (Both sides) -M50.8 (Both sides) 1.5 14 14 8 Monoblock manifold F type With valve output port fitting block 6-Rc1/8 (Both sides) 6 6 Number of units (59.5) 64.5) (44.3) 9 18 1 (65.5) 70.5) 50.3 -FJ5: (63.4) -FJ6: (65.4) PR 5 (R1) 3 (R) 1P 138.4 130.4 138.4 130.4 F(direct piping type) 88. 88. 5.5 3338 3 61 61 53 49.5 -FJ5: 36.9 -FJ6: 38.7 53 49.5 (B) port 4 (A) port.1 11.8 1 4 14 9 P L.5.5 14 (pitch) P B 4A L.5.5 (pitch) 9 -J5: 17.9 -J6:.7 (4).5 Quick fitting (4 or 6) Can also select M5x0.8 female thread 4-4.5 (Mounting hole) 14 49 4-4.5 (Mounting hole) Quick fitting (4 or 6) Can also select M5x0.8 female thread 11.8.1 56 Block-off plate 4 (A) port (B) port Block-off plate Unit dimensions Number of units 3 4 5 6 7 8 9 11 1 13 14 17 18 L 38.5 49.0 59.5 70.0 80.5 91.0 1.5 11.0 1.5 133.0 143.5 4.0 4.5 175.0 185.5 6.0 6.5 17.0 7.5 Values in brackets are for AC 0V specification. P 30.5 41.0 51.5 6.0 7.5 83.0 93.5 4.0 114.5 15.0 135.5 146.0 6.5 7.0 177.5 188.0 8.5 9.0.5 Unit dimensions Number of units 3 4 5 6 7 8 9 11 1 13 14 17 18 L 48.5 59.0 69.5 80.0 90.5 1.0 111.5 1.0 13.5 143.0 3.5 4.0 174.5 185.0 5.5 6.0.5 7.0 37.5 GFMF P 30.5 41.0 51.5 6.0 7.5 83.0 93.5 4.0 114.5 15.0 135.5 146.0 6.5 7.0 177.5 188.0 8.5 9.0.5 6 Values in brackets are for AC 0V specification. 469

GF Series Dimensions of Monoblock Compact Manifold A Type and F Type (Scale 1/3, Unit mm) GFM GFM Number of units Monoblock compact manifold A type With manifold output port fitting M50.8 (Both sides) 51 4.5 6.5 6Rc1/8 (Both sides) PR 5 (R1) 1 (P) 3 (R).6 0.6 (B) 4 (A) 4-4.5 (Mounting hole) Block-off plate Quick fitting (4 or 6) Can also select M5x0.8 female thread 6Rc1/8 (Both sides) 4.5 11 8 -FJ5: (56.4) -FJ6: (58.) 37.3 5 (R1) 1 (P) 3 (R) 17.1 Quick fitting (4 or 6) Can also select M5x0.8 female thread 4-4.5 (Both sides) 14 17.5 49 61 53 49.5 11.8 9 P L.5.5 pitch (9) -FJ5: 36.9 -FJ6: 38.7 Number of units Monoblock compact manifold F type With valve output port fitting block AC (59.5) 64.5) 44.3 13 9 FC J M (300) 138.4 130.4 88. 6 61 53 49.5 6 3338 4 14 L.5.5 14 (Pitch) P (4) 1.5 6.5 57 18.5 J5: (1.9) J6: (14.7) Unit dimensions Number of units 3 4 5 6 7 8 9 11 1 13 14 17 18 L 38.5 49.0 59.5 70.0 80.5 91.0 1.5 11.0 1.5 133.0 143.5 4.0 4.5 175.0 185.5 6.0 6.5 17.0 7.5 Values in brackets are for AC 0V specification. P 30.5 41.0 51.5 6.0 7.5 83.0 93.5 4.0 114.5 15.0 135.5 146.0 6.5 7.0 177.5 188.0 8.5 9.0.5 138.4 130.4 88. 4 (A) port (B) port Block-off plate Unit dimensions Number of units 3 4 5 6 7 8 9 11 1 13 14 17 18 L 48.5 59.0 69.5 80.0 90.5 1.0 111.5 1.0 13.5 143.0 3.5 4.0 174.5 185.0 5.5 6.0.5 7.0 37.5 P 30.5 41.0 51.5 6.0 7.5 83.0 93.5 4.0 114.5 15.0 135.5 146.0 6.5 7.0 177.5 188.0 8.5 9.0.5 470

GF Series Dimensions of Split Manifold, Non-Plug-in Type (Scale 1/3, Unit mm) GFM Number of units N Pilot specification (base piping type) With manifold output port fitting block J M GFMNJ 130.4 138.4 88. 6 61 53 49.5 Quick fitting (4 or 6) Can also select M5x0.8 female thread 3338 34 11.8 (1) 13.1 (7.5) Quick fitting 4 or 6) Can also select M5x0.8 female thread 130.4 138.4 88. 6 61 53 49.5 -FJ5: 36.9 -FJ6: 38.7 34 11.8 3.1 4 (A) port (B) port (1) (7.5) (B) port 4 (A) port L1 (L).5.5 14.8 8.5 (pitch) 4 P L1 (L).5.5 14.8 8.5 (pitch) 4 M50.8 (P port) (For external pilot specification) -J5: 1.9 -J6: 14.7 Block-off plate Quick fitting8 Can also select Rc1/4 female thread 30.5 93 3 1 (P) port 35 (R) port M50.8 (P Port) (For external pilot specification) -Quick fitting (8) Can also select Rc1/4 female thread 81 30.5 30 93 35 (R) port 1 (P) port Block-off plate 6873 5.8 GFM Number of units N Pilot specification (direct piping type) With valve output port fitting block 35 (1.5) 5.5.5 81 6873 5.8 -FJ5: 71.9 -FJ6: 73.9 5 (1) (1) DIN rail mounting hole dimensions 35 (1.5) 5.5.5 5 Unit dimensions Number L1 DIN rail L DIN rail of units length Note length Note 3 4 5 6 7 8 9 11 1 13 14 17 18 78.0 88.5 99.0 9.5 1.0 130.5 141.0 1.5.0 17.5 183.0 3.5 4.0 14.5 5.0 35.5 46.0 56.5 67.0 15 15 15 0 0 175 175 0 0 0 5 5 50 50 75 75 75 300 300 97.0 7.5 118.0 18.5 139.0 149.5 0.0 170.5 181.0 1.5.0 1.5 3.0 33.5 44.0 54.5 65.0 75.5 86.0 15 0 0 175 175 175 0 0 5 5 50 50 50 75 75 300 300 35 35 Note: When using two piping blocks. Values in brackets are for AC 0V specification. Unit dimensions Number of units 3 4 5 6 7 8 9 11 1 13 14 17 18 L1 78.0 88.5 99.0 9.5 1.0 130.5 141.0 1.5.0 17.5 183.0 3.5 4.0 14.5 5.0 35.5 46.0 56.5 67.0 DIN rail length 15 15 15 0 0 175 175 0 0 0 5 5 50 50 75 75 75 300 300 L Note 97.0 7.5 118.0 18.5 139.0 149.5 0.0 170.5 181.0 1.5.0 1.5 3.0 33.5 44.0 54.5 65.0 75.5 86.0 Note: When using two piping blocks. DIN rail mounting hole dimensions Values in brackets are for AC 0V specification. GFMN DIN rail length Note 15 0 0 175 175 175 0 0 5 5 50 50 50 75 75 300 300 35 35 471

Female Thread Specification (Scale1/3, Unit mm) Split manifold non-plug-in type Monoblock compact manifold A type M50.8 (P port) (For external pilot specification) 4-4.5 (Mounting hole) 57 18.5 -M50.8 -Rc1/4 M50.8 13.1 11.8 1 (P) port.6 0.6 1.5 6.5 35 (R) port Additional Parts (Sold Separately) Muffler: KM-J8 (Scale /3, Unit mm) 64 (38) 6 8 (55) 1 47

SOLENOID VALVES SERIES INDEX Specifications 474 Dimensions of Single Valve Unit 477 Dimensions of Monoblock Manifold 481 Dimensions of Monoblock Compact Manifold 48 Dimensions of Split Non-Plug-in Type 483 473