Emergency Light Fittings

Similar documents
7 Lighting Technology

Outdoor Light fittings

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Industrial Light Fittings

7 Lighting Technology

Emergency Light Fitting for Fluorescent Lamps Series 6009

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Luminaires CG-S Eaton. All Rights Reserved.

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

7 Lighting Technology

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Technical data SUPRA. High temperature ABS - PC. Acrylic or Polycarbonate. White lacquered steel plate A. 230V, 50Hz (electromagnetic)

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

Compact Sheet-Steel Light Fittings Series 6114

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Emergency Luminaire with LED Series EXLUX 6409/1

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Industrial luminaires

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Linear luminaire with LED Series EXLUX 6002

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Industrial luminaires

Applications. Illustrated Features

Easy and safe installation

Linear Luminaire with LED Series EXLUX 6002

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

LED Linear Luminaire Series EXLUX 6402

SEALA. Dust & Moisture Proof Luminaire

Protected

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Linear fluorescent luminaire LED V-CG-S

Compact Sheet-Steel Light Fittings Series 6114/1

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Emergency lighting units EM series

A LIFETIME OF LIGHT. Magnetic Ballasts (A2) plus Electronic Starter

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

7 Lighting Technology

Sheet Steel Emergency Light Fitting Series 6018

EMERGENCY. EYE Lighting Volume 6 Catalogue

Linear fittings Fluorescent fitting EVN - Zones 2 & 22

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

EURO ZB.1 Installation example

Emergency lighting units EM powerled

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

T U N N E L A N D U N D E R P A S S LIGHTING

Emergency lighting units EM LED Light Engines

Technical Application Guide for UP-SHINE LED Batten Light UP-DB W

Technical Application Guide for UP-SHINE LED Batten Light UP-DB W

Technical Application Guide for UP-SHINE LED Batten Light UP-DB W

Product advantages Bernina

Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

IIC wellglass luminaires for low energy, halogen and incandescent lamps flameproof

I-BRICK. High quality LED from Samsung. Curve shaped design. Vandal proof protective cover. Visual comfort. Available in 2 sizes.

7 Lighting Technology

Designed to... ENDURE. IP65 LED luminaire

Waterproof TCW060 just light

APOLO. High/Low bay reflectors

Emergency lighting units EM powerled

ADDRESSABLE SELF TESTING NON MAINTAINED SPOT LIGHT EMERGENCY LUMINAIRES WITH 1 WHITE POWER LED

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Component Systems. for Lighting Applications. January 2018

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

EXEL-L. Detail of the internal side. Transparent polycarbonate

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

MHDS SERIES M H D S. Stainless Steel Marine Heavy Duty Luminaire for Hazardous Locations

Nightscape High performance floodlights and spotlights for discharge lamps

Operating Instructions

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

PROTECTA III. Construction Tough glass reinforced polyester body

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22


Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Emergency lighting units EM Inverter

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

W A T E R P R O O F A N D C L E A N R O O M LUMINAIRES

Beam Type Lamp Type Gear Type. Rated Input Power

4.5. Ex Floodlights for high-pressure discharge lamps, series PX 04 and FLT 10. (Zone 1, 2, 21, 22)

Sheet-Steel Light Fittings Series 6014 / 6414

ATM Lighting sp. z o.o

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

FLC131 LED + Linear spread lens IO

Transcription:

Emergency Light Fittings

164 131 208/... 218/25.. SCHUCH Emergency Light Fittings NEW 164 218/25.. Dustproof/waterproof emergency light fitting for wind power stations. Description Series Page Polyester with Diffuser Insulation class II Insulation class I 161/162 180 163/164 182 164... KL B/D 184 131... B/D 186 Polyester without Diffuser Insulation class II 175 188 NEW 131 208/... Small shock resistant emergency light fitting for wind power stations. Emergency Light Fittings for Wind Power Stations Insulation class I 164218/... 190 131208/... 191 501/101 192 Emergency Light Power Supply Unit N 12 195 GV 197 ZB 198 Emergency Light Fitting

Modes of functioning Dustproof/Waterproof Polyester Emergency Light Fittings of Insulation Class II Series 161... / 162... For illumination of working places and acc. to DIN VDE 0108 for illuminating and identifying escape routes etc. Mechanical Data: Housing: Glass fibre reinforced polyester resin, polyurethane gasket. Diffuser: Injected clear acrylic glass or polycarbonate (PC) each with internal prisms. Closure: External plastic clips (KK). Stainless steel clips (KE) available upon request and at extra charge. Reflector: Glass fibre reinforced polyester resin, that can be suspended or removed. It carries the electrical components which are protected against accidental contact. Connection: 3-pole plug-in terminal. Cable entry: 2 plugs M20 x 1,5. Looping the cable at one small end of the housing upon request and at extra charge. Through wiring system: Up to 5x2,5mm 2 (extra charge). Mounting system:closed knock-outs for direct ceiling mounting, rubber sealing washers inside each fitting. Wiring diagram 161... maintained operation Wiring diagram 162... maintained operation Electrical Data: (series 161... / 162... only) Incorporated NiCd battery set which is constantly charged and therefore ready for operation any time. Visual monitoring the battery charging process through LED. Electronic deep discharge protection. Re-charging time: 24 hours acc. to EN 60598-2-22. Luminous flux raising i.e. initially the emergency lamp has got a higher luminous flux. Modes of functioning: Maintained operation = in case of mains failure 1 lamp is switched over to battery operation. In the 2-lamp version (type 162...) only one lamp will be operating as emergency lighting. Connection voltage: 230V, 50Hz (standard) Ambient temperatures convent. ballast: -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) Ambient temperatures (EVG): -5 C up to +40 C (maintained version) Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Do not connect L1 Shock resistance test: RK 1.0 / 10A 161... / 162... with battery set T 26 T 38 161 158... 162 258... Type Article no. Lamps/ Flux factor Weight Watts approx. % approx. kg 1 hour emergency operation, with conventional ballasts 161 136/34/1 16110 0025 1 x T 26/36 W 34 4,1 161 136/18/1 4) 5) 16110 0009 1 x T 26/36 W 18 4,0 161 158/22/1 16110 0026 1 x T 26/58 W 22 5,5 161 158/15/1 4) 5) 16110 0010 1 x T 26/58 W 15 5,3 162 218/65/1 16210 0083 2 x T 26/18 W 65 4,4 162 218/38/1 4) 5) 16210 0076 2 x T 26/18 W 38 4,5 162 236/34/1 16210 0084 2 x T 26/36 W 34 7,0 162 236/50/1 16210 0085 2 x T 26/36 W 50 7,7 162 236/18/1 4) 5) 16210 0051 2 x T 26/36 W 18 6,9 162 258/22/1 16210 0086 2 x T 26/58 W 22 9,1 162 258/31/1 16210 0087 2 x T 26/58 W 31 9,8 162 258/15/1 4) 5) 16210 0054 2 x T 26/58 W 15 9,0 Series 161... Series 162... 1 hour emergency operation, with electronic ballast (EVG) 161 136/34/1 EVG 16110 0027 1 x T 26/36 W 34 4,1 161 136/18/1 EVG 4) 5) 16110 0017 1 x T 26/36 W 18 4,0 161 158/22/1 EVG 16110 0028 1 x T 26/58 W 22 5,5 161 158/15/1 EVG 4) 5) 16110 0018 1 x T 26/58 W 15 5,3 162 218/65/1 EVG 16210 0082 2 x T 26/18 W 65 4,4 162 218/38/1 EVG 4) 5) 16210 0077 2 x T 26/18 W 38 4,5 162 236/34/1 EVG 16210 0078 2 x T 26/36 W 34 7,0 162 236/50/1 EVG 16210 0079 2 x T 26/36 W 50 7,7 162 236/18/1 EVG 4) 5) 16210 0062 2 x T 26/36 W 18 6,9 162 258/22/1 EVG 16210 0080 2 x T 26/58 W 22 9,1 162 258/31/1 EVG 16210 0081 2 x T 26/58 W 31 9,8 162 258/15/1 EVG 4) 5) 16210 0063 2 x T 26/58 W 15 9,0 1) Wiring uncompensated only 2) Ratio effective lamp flux/nominal flux 3) Weights without packing material 4) MA version possible (see further series) 5) 3h emergency operation possible Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 180

161... / 162... EVG for connection to central power supply unit For connection to group or central battery systems or to an emergency mains for illuminating escape routes, ships or vehicles etc. Electrical design: Electronic ballasts (230V AC / DC). A double lamp luminaire will be equipped with 2 electronic ballasts, separate lamp circuits and separate connection terminals. T 26 162 2.. EVG T 38 Type Article no. Lamps/ Weight Watts approx. kg with electronic ballast (EVG) 161 118 EVG 16100 0018 1 x T 26/18 W 2,1 161 136 EVG 16100 0019 1 x T 26/36 W 2,8 161 158 EVG 16100 0020 1 x T 26/58 W 4,2 with 2 individual electronic ballasts (EVG/2) 162 218 EVG/2 16200 0353 2 x T 26/18 W 2,3 162 236 EVG/2 16200 0354 2 x T 26/36 W 3,0 162 258 EVG/2 16200 0356 2 x T 26/58 W 4,4 1) Weights without packing material Further series / equipment for series 161... / 162... only:.../b stand-by system = emergency lighting in case of mains failure only (series 162... with 1 lamp = 1621.. only).../p button for testing the emergency light function.../3 3 hour emergency operation for series 161... / 162... EVG only: with separate or integrated monitoring module for connection to group or central power supply unit with system for monitoring each individual luminaire. (For any inquiry please indicate the make of the equipment used.) with electronic ballast for voltages: 110V DC, 24V DC with conventional ballast 230V, 50 Hz Type 162 218... with legend.../35 for types 161... / 162.../.. EVG only:.../ma automatic monitoring the emergency light fitting with weekly functioning test and indication of the test results by LED (luminescence diode) at the luminaire. For further equipment please see catalogue section Dustproof / Waterproof luminaires of series 161 / 162... Emergency Notleuchten Light Fittings Self adhesive legends.../33 W.../34 W.../35 W for escape route identification acc. to BGV A8 and DIN 4844-2. Sighting distance acc. to EN 1838 and DIN 4844 = 25m. Accessories / Spare Parts Type Article no. Self adhesive legends for series 162 118 and 162 218 590/125/33 W 59000 0004 590/125/34 W 59000 0005 590/125/35 W 59000 0006 Emergency exit to the left Emergency exit to the right Emergency exit below For further accessories and spare parts please see catalogue section Dustproof / Waterproof luminaires of series 161... / 162... When ordering any electronic components or battery sets please do always indicate the type nos. of the light fittings. 181 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

Dustproof / Waterproof Polyester Emergency Light Fittings of Insulation Class I Series 163... / 164... For illumination of working places and acc. to DIN VDE 0108 for illuminating and identifying any escape routes etc. Mechanical Data: Housing: Glass fibre reinforced polyester resin, polyurethane gasket. Diffuser: Stippled clear acrylic (PMMA) with impact resistant component or polycarbonate (PC), hinged at one side. Closure: External plastic clips (KK). Stainless steel clips (KE) upon request and at extra charge. Reflector: Sheet steel, finished in white, detachable, carrying the electrical components. Quick release turn buckle fasteners for quick installation. Connection: 4-pole connection terminal. Cable entries: At the small front sides and at the upper side of the housing, also for looping the mains cable at one side (types 1631.. also at the long side), 2 plugs M20. Through wiring system: Up to 7x2,5mm 2 or 5x4mm 2 (extra charge). Mounting system: 2 points for direct ceiling mounting; rubber gaskets and washers inside the fitting. Wiring diagram 163... maintained operation Wiring diagram 164... maintained operation Electrical Data: Incorporated NiCd battery set which is constantly charged and therefore ready for operation at any time. Visual monitoring the battery charging process by LED (luminescence diode). Electronic deep discharge protection. Re-charging time: 24 hours acc. to EN 60598-2-22. Modes of functioning: Maintained operation = in case of mains failure 1 lamp is switched over to battery operation. Connection voltage: 230V, 50Hz (standard) Ambient temperatures: -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) Ambient temperature (EVG): -5 C up to +40 C (maintained version) Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Do not connect L1 163... / 164... with battery set T 26 163 158/... Type Article no. Lamps/ Flux factor-weight Watts Watts approx. % 2) approx. kg 3) 1 hour emergency operation, with conventional ballast 163 136/18/1 16310 0001 1) 1 x T 26/36 W 18 4,4 163 158/15/1 16310 0002 1) 1 x T 26/58 W 15 6,1 164 218/38/1 16410 0017 2 x T 26/18 W 38 4,5 164 236/18/1 16410 0001 1) 2 x T 26/36 W 18 9,1 164 258/15/1 16410 0002 1) 2 x T 26/58 W 15 10,9 163... Series 163... Series 164... 1 hour emergency operation, with electronic ballast (EVG) 163 136/18/1 EVG 16310 0005 1 x T 26/36 W 18 4,0 163 158/15/1 EVG 16310 0006 1 x T 26/58 W 15 5,3 164 218/38/1 EVG 16410 0018 2 x T 26/18 W 38 4,5 164 236/18/1 EVG 16410 0005 2 x T 26/36 W 18 8,2 164 258/15/1 EVG 16410 0009 2 x T 26/58 W 15 8,9 1) Wiring uncompensated only 2) Ratio effective lamp flux/nominal flux 3) Weights without packing material Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 182

163... / 164... EVG for connection to central power supply unit For connection to group or central battery systems or to an emergency mains for illuminating escape routes or for emergency lighting on ships, vehicles etc. Electrical design: Electronic ballasts (230V AC / DC). A double lamp luminaire will be equipped with 2 electronic ballasts, separate lamp circuits and separate connection terminals. T 26 Type Article no. Lamps/ Weight Watts approx. kg 1) 164... EVG with electronic ballast (EVG) 163 118 EVG 16300 0010 1 x T 26/18 W 1,5 163 136 EVG 16300 0011 1 x T 26/36 W 2,5 163 158 EVG 16300 0012 1 x T 26/58 W 2,8 with 2 individual electronic ballasts (EVG) 164 218 EVG/2 16400 0145 2 x T 26/18 W 2,7 164 236 EVG/2 16400 0146 2 x T 26/36 W 4,0 164 258 EVG/2 16400 0147 2 x T 26/58 W 5,7 1) Weights without packing material Further series / equipment for series 163... / 164... only::.../b stand-by system = emergency lighting in case of mains failure only (series 164... with 1 lamp = 1641.. only).../p button for testing the emergency light function.../3 3 hour emergency operation Special version for wind power stations (see special data sheet). for series 163... / 164... EVG only: with electronic ballast (EVG) for the following voltages: 110 V DC, 24V DC with separate or integrated monitoring module for connection to group or central battery systems with device for monitoring each individual luminaire.(for any inquiry please indicate the make of the equipment used.). Type 164 218... with legend.../35 for series 163... / 164... EVG only:.../ma automatic monitoring the emergency light fitting with weekly functioning test and indication of the test results by LED (luminescence diode) at the luminaire For further equipment please see catalogue section Dustproof / Waterproof luminaires of series 163 / 164... Emergency Notleuchten Light Fittings Self adhesive legends.../33 W.../34 W.../35 W for escape route identification acc. to BGV A8 and DIN 4844-2. Sighting distance acc. to EN 1838 and DIN 4844 = 25m. Accessories / Spare Parts Type Article no. Self adhesive legends for series 164 118 and 164 218 590/125/33 W 59000 0004 590/125/34 W 59000 0005 590/125/35 W 59000 0006 Emergency exit to the left Emergency exit to the right Emergency exit below For further accessories and spare parts please see catalogue section Dustproof / Waterproof luminaires of series 163... / 164... When ordering any electronic components or battery sets please indicate the type nos. of the light fittings. 183 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

Polyester Emergency/Escape Sign Light Fittings Series 164... KL B/D In humid, wet and dusty locations, commercial and industrial premises, agricultural buildings, car parks, basements, kitchens, protective locations for civil defence, for illumination and identification of escape routes. Mechanical Data: Housing: Glass fibre reinforced polyester, polyurethane gasket. Difuser: Clear stippled PMMA with impact resistant components, hingeable on both sides. Also available in white (W) or clear (K) PMMA or clear stippled (PC) or clear (K PC). Closure: plastic clips (KK). Stainless steel (KE) upon request and at extra charge. Reflector: Sheet steel finished white, detachable, carrying the electrical components. Quick release turn buckle fasteners allow a quick installation. Connection: 3/4-pole connection terminal. Cable entries: At the small front sides and at the upper side of the housing, also for looping the mains cable at one side, 2 plugs M20. Through wiring system: At extra charge. Mounting system: 2 points for direct ceiling mounting; rubber gaskets and washers inside the fitting. Wiring diagram 164 1.. KL B stand-by Wiring diagram 164 1.. KL D maintained Electrical Data: NiCd battery set - gastight - mounted on the reflector. The battery set is constantly charged and therefore ready for operation at any time. Visual monitoring the battery charging process through LED (luminescence diode). Electronic deep discharge protection. Re-charging time: 24 hours acc. to EN 60598-2-22. Modes of functioning:... B = stand-by operation = in case of mains failure the lamp is on.... D =maintained operation = in case of mains failure the lamp is switched over to battery operation. Connection voltage: 230V, 50Hz (standard) Ambient temperatures: -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Do not connect L1 164... KL B/D IP 65 with battery set T 16 TC-SEL TC - L Type Article. Lamps/ Em.- Flux factor Weight no. Watts hours appr.% 2) kg 3) By looping the cable at one side a conventional through wiring system is not required. Note: An EXIT sign on 2 sides requires 2 light fittings which are connected by means of a ceiling or a wall bracket (see accessories / spare parts). 164 108 KL maintained or stand-by version 1) 164 108/45 KL B/D1 16409 0021 1 x T 16/8 W 1 45 2,2 164 108/36 KL B/D3 16409 0022 1 x T 16/8 W 3 36 2,4 164 111/25 KL B/D1 16409 0023 1 x TC-SEL 11 W 1 25 2,2 164 111/20 KL B/D3 16409 0024 1 x TC-SEL 11 W 3 20 2,4 stand-by version (B) 1) 164 118/39 KL B1 16409 0029 1 x TC-L 18 W 1 39 2,3 164 118/46 KL B3 16409 0030 1 x TC-L 18 W 3 46 2,9 maintained version (D) with electronic ballast (EVG) 164 108/45 KL D1 EVG 16409 0025 1 x T 16/8 W 1 45 2,1 164 108/36 KL D3 EVG 16409 0026 1 x T 16/8 W 3 36 2,3 164 111/25 KL D1 EVG 16409 0027 1 x TC-SEL 11 W 1 25 2,1 164 111/20 KL D3 EVG 16409 0028 1 x TC-SEL 11 W 3 20 2,3 1)Wiring uncompensated only 3) Weights without packing material 2)Ratio effective lamp flux/nominal flux Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 184

Series 164 1..KL SB 164... KL EVG IP 65 for connection to central power supply unit For connection to group or central battery systems with/without monitoring the individual luminaires or for connection to an emergency mains for identifying and illuminating escape routes. Mechanical Data: Types...S. = with high or low bay reflector. Electrical Data: With electronic ballast (230V AC / DC). Series 164 1..KL SB T 16 TC-SEL TC - L 164 108 KL 164 108 KL SB Type Article no.. Lamps/ Weight Watts approx. kg 1) with electronic ballast (EVG) 164 108 KL EVG 16404 0084 1 x T 16/8 W 1,1 164 111 KL EVG 16404 0063 1 x TC-SEL 11 W 1,1 164 118 KL EVG 16404 0015 1 x TC-L 18 W 1,2 with high bay reflector (SB) and electronic ballast (EVG) 164 108 KL SB EVG 16404 0130 1 x T 16/8 W 1,3 164 111 KL SB EVG 16404 0142 1 x TC-SEL 11 W 1,3 164 118 KL SB EVG 16404 0154 1 x TC-L 18 W 1,4 with low bay reflector (ST) and electronic ballast (EVG) 164 108 KL ST EVG 16404 0124 1 x T 16/8 W 1,2 164 111 KL ST EVG 16404 0136 1 x TC-SEL 11 W 1,2 164 118 KL ST EVG 16404 0148 1 x TC-L 18 W 1,3 1) Weights without packing material Series 164 1..KL ST 164 111 KL ST Series 164... KL with legend Further series / equipment for series 164... KL B/D only: -.../P button for testing the emergency light function for series 164... KL B. and KL D. EVG: -.../MA automatic monitoring the emergency light fitting with weekly functioning test and indication of the test results by LED (luminescence diode) at the luminaire. for series 164... KL EVG only: - with electronic ballast (EVG) for the following voltages: 110 V DC, 24V DC, 12V DC - with separate or integrated monitoring module for connection to group or central battery systems with device for monitoring each individual luminaire. (For any inquiry please indicate the make of the equipment used.) For further equipment please see catalogue section Dustproof / Waterproof luminaires of series 163 / 164... KL NEW Self adhesive legends green/white 1) 121/33 W 121/34 W 121/35 W for clear stippled or clear covers for escape route identification acc. to BGV A8 and DIN 4844-2. Sighting distance acc. to EN 1838 and DIN 4844 = 30m. 1) not for white opalescent covers Accessories / Spare Parts Type Article no. Spare glasses 164000 16413 9000 164000 W 16413 9001 164000 K 16413 9004 164000 PC 16413 9002 164000 K PC 16413 9005 Brackets WA 45 90232 0002 WA 90 90232 0003 DA 90232 0004 121/33 W 12112 0006 121/34 W 12112 0007 121/35 W 12112 0008 PMMA clear stippled PMMA white opalescent PMMA clear PC clear stippled PC clear wall bracket 45 wall bracket 90 ceiling bracket Standard legends, self adhesive (for clear stippled or clear light fittings) emergency exit left emergency exit right emergency exit below Further legends and wordings upon request. For further accessories and spare parts please see catalogue section Dustproof / Waterproof luminaires of series 164... KL When ordering any electronic components or battery sets please do always indicate the type nos. of the light fittings. Emergency Notleuchten Light Fittings 185 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

Small shock resistant Emergency/Escape Sign Light Fittings Series 131... B/D At working places and meeting places, humid and wet rooms, for illuminating and indicating escape routes. Mechanical Data: Housing: White polycarbonate. Diffuser: Injected, clear polycarbonate with internal prisms or white opalescent (W). Multiple hinge at one small side for suspending and unhinging purpose. Captive stainless steel screw on the other side for closing the fitting. Connection: 3- / 4-pole terminal. Cable entries: 1 plug M20 at each of the small sides. Mounting system: 2 points at the upper side of the housing for direct ceiling mounting; rubber gaskets and washers inside the fitting. Wiring diagram 131... D/B maintained/stand-by Wiring diagram 131 1... B stand-by Electrical Data: (series 131... B/D only) NiCd battery set - gastight - mounted on the reflector. The battery set is constantly charged and therefore ready for operation at any time. Visual monitoring of the battery charging process by LED (luminescence diode). Electronic deep discharge protection. Re-charging time: 24 hours acc. to EN 60598-2-22. Modes of functioning:... B = stand-by operation = in case of mains failure the lamp is on.... D = maintained operation = in case of mains failure the lamp is switched over to battery operation.... MA = automatic monitoring the emergency light fitting with weekly functioning test and indication of the test results by LED (luminescence diode) at the luminaire. Connection voltage: 230V, 50Hz (standard) Ambient temperatures: -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Do not connect L1 131... B/D with battery set Shock resistance test: RK 1.0 / 10A T 16 TC - L Type Article. Lamps/ Em.- Flux factor Weight no. Watts hours appr.% 2) kg 4) maintained and stand-by version 1) 131 108/.. B. 131 108/45 W B/D1 13110 0014 1 x T 16/8 W 1 45 1,8 131 108/36 W B/D3 13110 0015 1 x T 16/8 W 3 36 1,8 maintained version with electronic ballast (EVG) and automatic monitoring system 131 108/45 W D1 EVG MA 13110 0016 1 x T 16/8 W 1 45 1,8 131 108/45 W D3 EVG MA 13110 0017 1 x T 16/8 W 3 36 1,8 stand-by version 131 118/39 W B1 3) 13110 0018 1 x TC-L 18 W 1 39 2,0 stand-by version with automatic monitoring system 131 118/17 W B1 MA 13110 0022 1 x TC-L 18 W 1 17 1,8 131 118/17 W B3 MA 13110 0024 1 x TC-L 18 W 3 17 2,0 1) Wiring uncompensated only 2) Ratio effective lamp flux/nominal flux 3) Also available with MA 4) Weights without packing material Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 186

131... EVG for connection to central power supply unit For connection to group or central battery systems or to emergency mains for illuminating escape routes or for emergency illumination on ships, vehicles etc. TC-SEL TC - L Type Article no. Lamps/ Weight Watts approx. kg 1 with electronic ballast (EVG) 131 111 EVG 13100 0013 1 x TC-SEL 11 W 1,0 131 118 EVG 13100 0015 1 x TC-L 18 W 1,0 131 111 EVG 110V DC 13100 0046 1 x TC-SEL 11W 1,0 131 111 EVG 24V DC 13100 0017 1 x TC-SEL 11W 1,0 131 111 EVG 12V DC 13100 0016 1 x TC-SEL 11W 1,0 1) Weights without packing material Further series / equipment for series 131... B/D only:... P button for testing the emergency light function... EVG with electronic ballast... AB device for putting out of operation Special version for wind power stations (Please ask for our special data sheet). Electrical Data: Electronic ballasts (230V AC / DC, 110V DC, 24V DC or 12V DC). A double lamp luminaire will be equipped with 2 electronic ballasts, separate lamp circuits and separate connection terminals. for series 131... EVG only: with conventional ballast 230V, 50Hz with separate or integrated monitoring module for connection to group or central battery systems with device for monitoring each individual luminaire. (For any inquiry please indicate the make of the equipment used.) For further equipment please see catalogue section Dustproof / Waterproof luminaires of series 130 / 131 / 132... Type 131... with standard legend Self adhesive legends for escape route identification acc. to BGV A8 and DIN 4844-2. Sighting distance acc. to EN 1838 and DIN 4844 = 15m. Accessories / Spare Parts Type Article no. Standard legend, self adhesive 265/76/3 90011 0002 Note: Further legends and wordings upon request. Emergency Notleuchten Light Fittings For further accessories and spare parts please see catalogue section Dustproof / Waterproof luminaires of series 130... / 131... / 132... When ordering any electronic components or battery sets please indicate the type nos. of the light fittings. 187 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

Dustproof/Waterproof Polyester Emergency Light Fittings of Insulation Class II - without diffuser Series 175... For illumination of working places and acc. to DIN VDE 0108 for illuminating and identifying escape routes etc. Mechanical Data: Housing: Glass fibre reinforced polyester resin. Gasket: Weatherproof, non-ageing and chemically resistant profile gasket. Electrical components: Mounted on the inner side of the suspended polyester lid. Starter easily accessible from outside the fitting. Moisture-proof lampholders with rotating contact system, neoprene gasket. Cable entries: At the small front sides and at the upper side of the housing, also for looping the mains cable at one side. 2 plugs M20. Connection: 3-pole connection terminal. Through wiring system: Up to 5 x 2,5mm 2 possible, at extra charge. Mounting system: Closed knock-outs for direct ceiling mounting; rubber gaskets and washers inside the fitting. Wiring diagram 175 1... maintained operation Wiring diagram 175 2... maintained operation Electrical Data: (series175...only) Incorporated NiCd battery set which is constantly charged and therefore ready for operation at any time. Visual monitoring the battery charging process by LED (luminescence diode). Electronic deep discharge protection. Re-charging time: 24 hours acc. to EN 60598-2-22. Luminous flux raising i.e. initially the emergency lamp has got a higher luminous flux. Only one lamp is operating in the emergency case. Modes of functioning: Maintained operation = in case of mains failure 1 lamp is switched over to battery operation. Connection voltage: 230V, 50Hz (standard) Ambient temperatures: -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Do not connect L1 Series 175 1.. Series 175 2.. 175... with battery set T 26 Type Article no. Lamps/ Flux factor Weight Watts approx. % 2) approx. kg 3) 1 hour emergency operation, with conventional ballast 175 158/../. 175 136/18/1 17510 0005 1) 1 x T 26/36 W 18 3,1 175 158/15/1 17510 0006 1) 1 x T 26/58 W 15 4,4 175 236/18/1 17510 0007 1) 2 x T 26/36 W 18 4,6 175 258/15/1 17510 0008 1) 2 x T 26/58 W 15 5,7 1 hour emergency operation, with electronic ballast (EVG) 175 136/18/1 EVG 17510 0009 1 x T 26/36 W 18 2,9 175 158/15/1 EVG 17510 0010 1 x T 26/58 W 15 3,9 175 236/18/1 EVG 17510 0011 2 x T 26/36 W 18 3,2 175 258/15/1 EVG 17510 0012 2 x T 26/58 W 15 4,2 1) Wiring uncompensated only 3) Weights without packing material 2) Ratio effective lamp flux/nominal flux Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 188

175... EVG for connection to central power supply unit For connection to group or central battery systems or to an emergency mains for illuminating escape routes, ships or vehicles etc. Electrical design: Electronic ballast (230V AC / DC, 110V DC, 24V DC). A double lamp luminaire will be equipped with 2 electronic ballasts, separate lamp circuits and separate connection terminals. 175 258 EVG T 26 Type Article no. Lamps/ Weight Watts approx. kg 1 with electronic ballast (EVG) 175 118 EVG 17500 0019 1 x T 26/18 W 1,1 175 136 EVG 17500 0020 1 x T 26/36 W 1,7 175 158 EVG 17500 0021 1 x T 26/58 W 2,0 with 2 individual electronic ballasts (EVG/2) 175 236 EVG/2 17500 0226 2 x T 26/36 W 2,0 175 258 EVG/2 17500 0225 2 x T 26/58 W 2,2 1) Weights without packing material Further series / equipment for series 175.../.../. only:.../b stand-by system = emergency lighting only in case of mains failure.../3 3 hour emergency operation for series 175.../../. EVG only:.../ma automatic self-monitoring and indication of the results, weekly functioning test and yearly long-time test acc. to DIN VDE 0108. for series 175... EVG only: with separate or integrated monitoring module for connection to group or central battery equipment with system for monitoring each individual luminaire. (For any inquiry please indicate the make of the used equipment.). with electronic ballast for special voltages: 110V DC, 24V DC with conventional ballast 230V, 50 Hz for both series: with external reflectors with rotable snap-on reflectors with protective tube S38 or S50 with oval-shaped protective tube S0 also in FF version with through wiring system up to 5x2,5mm 2 with different cable entries up to M25 x 1,5 for fluo tubes of 38mm (with enlargement rings 1681/38) Emergency Notleuchten Light Fittings Accessories / Spare Parts For accessories and spare parts please see catalogue section Dustproof / Waterproof luminaires of series 175... When ordering any electronic components or battery sets please do always indicate the type nos. of the light fittings. 189 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

NEW Dustproof/Waterproof Emergency Light Fitting for Wind Power Stations Series 164 218/../1 or / 3 Inside towers of wind power stations for lighting escape routes, baskets and platforms (places of maintenance and repair work). Mechanical Data: Housing: Glass fibre reinforced polester, inserted profile gasket. Diffuser: Stippled clear polycarbonate, hingeable at both sides. Closure: External plastic clips (KK). Stainless steel clips available upon request (KE) at extra charge. Reflector: Sheet steel finished in white, detachable, carrying the electrical components. Quick release turn buckle fasteners allow a quick installation. Connection: 4-pole connection terminal. Cable entries: at the small front sides and at the upper side of the housing, also for looping the mains cable at one side. All cable entries are closed knock-outs. 2 plugs M20 Mounting: 2 points for direct ceiling mounting; rubber gaskets and washers inside the fitting. SCHUCH Quality - Your advantage: housing and diffuser made from reinforced polycarbonate (robust and shockproof) economic application by looping facility of mains cable simple to instal and to maintain Shock resistance test: RK 1.0 / 10A Electrical Design: All electrical components are mounted on the reflector. 2 strings protect the reflector from accidental dropping. The 4-pole connection terminal is mounted on the reflector. NiCd batteries, gastight. The battery set is constantly charged and therefore ready for operation at any time. Visual monitoring the battery charging process by LED (luminescence diode). Electronic deep discharge protection. Re-charging time: 24 hours acc. to EN 60598-2-22. Mode of operation: Light fitting in stand-by version (light switch in off-position). By switching the light on the fitting is set to maintained operation (both lamps on). Switching to battery operation takes place if there is a mains failure.(1 lamp on as security lighting) Connection voltage: 230V, 50Hz Ambient temperatures (convent. ballast): -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) 662-18W 400-18W Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Do not connect L1 Maintained operation: Central on 164 218/../. with battery set Type 1) Article no.. Emergency Lamps/ Flux factor Weight T 26 hours Watts approx.% 2) approx. kg 3) with conventional ballast 164 218/25/. 164 218/25/1 16410 0013 1h 2 x T 26/18 W 25 4,4 164 218/25/3 16410 0014 3h 2 x T 26/18 W 25 4,7 164 218/60/1 16410 0019 1h 2 x T 26/18 W 60 4,7 1) Uncompensated version only 2) Ratio effective lamp flux/nominal flux 3) Weights without packing material Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 190

NEW Small shock resistant Emergency Light Fitting for Wind Power Stations Type 131 208 D3/M2001 P3 Inside towers of wind power stations (places of maintenance and repair work). Mechanical Data: Housing: White polycarbonate. Diffuser: Injected clear polycarbonate with internal prisms. Multiple hinge at one small side for suspending and unhinging purpose. Captive stainless steel screw on the other side for closing the fitting. Connection: 4-pole terminal. Cable entries: 2 plugs M20 at one small side for looping the mains cable. Through wiring system not necessary. Mounting system: 2 points at the upper side of the housing for direct ceiling mounting; rubber gaskets and washers inside the fitting. SCHUCH Quality - Your advantage: housing and diffuser made from polycarbonate (robust and shockproof) economic application by looping facility of mains cable simple to install and to maintain Shock resistance test: RK 1.6 / 16A Electrical design: All electrical components are mounted on the reflector. A string protects the reflector from accidental dropping. The 4-pole connection terminal is located in the lower section of the housing. NiCd batteries, gastight. The battery set is constantly charged and therefore ready for operation at any time. Visual monitoring of the battery charging process by LED (luminescence diode). Electronic deep discharge protection. Recharging time: 24 hours, acc. to EN 60598-2-22. Mode of operation: Light fitting in stand-by version (light switch in off-position). By switching the to on-position the fitting is set to maintained operating (1 lamp on). Attention: Luminaire is not suitable for continuous maintained operation. At any mains failure the fitting switches over to battery operation. For this purpose the second fluo tube is the emergency lamp. Connection voltage: 230V, 50Hz Ambient temperatures (convent. ballast): -5 C up to +30 C (maintained version) -5 C up to +40 C (stand-by version) Starting: Connect battery conductor Out of operation: Disconnect battery conductor Stand-by operation: Central off Maintained operation: Central on 131208 D3/M2001 P3 with battery set T 16 Type 1) Article no.. Lamps/ em. flux factor Weight 3) Watts hours approx. % 2) approx. kg 131 208 D3/M2001 P3 131 208 D3/M2001 P3 13110 8900 2 x T16/8W 3 35 1,8 1) Uncompensated version only 2) Ratio effective lamp flux/nominal flux 3) Weights without packing material Emergency Notleuchten Light Fittings 191 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

Emergency Light Power Supply Unit Series N 12... As power supply for 1 or 2 light fittings from 7W to 65W which are installed separately from the N device in a different room. It is especially recommendable for cases of installation where by reason of existing environmental conditions light fittings with their own individual battery sets must not be applied. Mechanical design: Housing: ABS, grey, 4 cable glands M20x1.5. Battery and electronic device: Separate section each for the inverter and for the battery set acc. to DIN VDE 0510 part 1. Mounting: Borings of a 6mm for direct wall mounting. Admissible ambient temperature: -5 C up to +40 C. Attention: Distance between the light fitting and the N device: 500 m max. Line drop acc. to DIN VDE 0100 to be considered. Wiring diagrams for light fittings with lowloss/conventional ballasts 1 lamp / 2 lamps single power supply unit double power supply unit Electrical design: Individual battery emergency power supply units for operating 1 or 2 light fittings with fluorescent tubes and electronic ballasts (EVG) or conventional ballasts. Equipment acc. to DIN VDE 0108, DIN VDE 0510, section 7 and IEC 598, section 2-22 in ASIC- Technology Emergency light electronic unit with deep discharge protection and switching-over device for mains/emergency light operation. Individual inverter for light flux controlled battery operation. Visual function monitoring by LED. Lead batteries with plug-in connection, maintenance-free. Closing-down connection With Luminous flux raising device (...H): Initially the emergency lamp has got a higher luminous flux., good starting procedure in case of low temperatures. Modes of operation: Maintained or stand-by operation. Maintained operation: Switching over to battery operation in case of mains failure. Stand-by operation: Emergency light lamp switches on in case of mains failure only. Mains voltage: 230V, 50 Hz Light fittings that can be conneted: Light fittings for fluorescent tubes with conventional ballast: Uncompensated and with electronic starter. Light fittings for fluorescent tubes with electronic control gear (EVG): Double lamp fittings with double ECG, please consider double current consumption or use luminaires with 2 ECGs (cutting the 2 systems). Note:The ECGs in the light fittings connected to the power supply unit must be suitable for operation with DC and AC voltages and for application in an equipment acc. to DIN VDE 0108. Light fittings for GLS lamps: Connection consumption acc. to the admissible consumption of fluo tubes. Note: All conventional ballasts must be suitable for operation at 50/60 Hz. The light fittings must be equipped with an electronic starter and wired without condenser. Mounting hole of 6mm N 12... with separate housing each for the inverter and for the battery set inverter Type Article no. Lamps/ Flux factor Weight Watts approx.% 1) appr. kg 2 for light fittings with conventional ballast uncomp.,1 hour operating N12/118-58/8/1 12000 0027 1 x 18 58 W 75 9,1 N12/218/8/1 12000 0028 2 x 18 W 75 9,1 N12/236-58/8/1 12000 0029 2 x 36 58 W 75 12,8 for light fittings with conventional ballast uncomp., 3 hours operating N12/118-58/8/3 12000 0030 1 x 18 58 W 75 12,8 N12/218/8/3 12000 0031 2 x 18 W 75 12,8 N12/236-58/8/3 12000 0032 2 x 36 58 W 75 12,8 for light fittings with electronic ballast (EVG)- 1 hour operating N12/118-58/8/1 EVG 12000 0033 1 x 18 58 W 100 9,1 N12/218-36/8/1 EVG 12000 0034 2 x 18 36 W 100 9,1 N12/258/8/1 EVG 12000 0035 2 x 58 W 100 12,8 for light fittings with electronic ballast (EVG)- 3 hours operating N12/118-58/8/3 EVG 12000 0036 1 x 18 58 W 100 12,8 N12/218-36/8/3 EVG 12000 0037 2 x 18 36 W 100 12,8 N12/258/8/3 EVG 12000 0038 2 x 58 W 100 13,1 1) ratio effective flux/rated lamp flux 2) Weights without packing material batterie set IP32 Emergency Notleuchten Light Fittings 195 Bitte beachten Sie die Hinweise Subject im to Technischen technical changes Anhang!

Wiring diagrams for ECG (EVG) luminaires 1 lamp 2 lamps single power on supply unit e.g. double power on supply unit e.g. Note: The ECGs (electronic control gears) must be suitable for DC/AC voltage and DC/AC current as well as for the application in equipments acc. to DIN VDE 0108. Further series / equipment CHECK INFO (index I) With the following functions: cyclic monitoring the charging procedure in intervals of < 5min. automatic execution of weekly 5min. function tests to verify the functions of the switch-over devices, the individual inverters and the lamp automatic execution of yearly 40-120 min. termoperation test to verify the operating time of the battery. display of the battery status and test results. CHECK BUS (index: B): Distance monitoring facility for single- battery luminaire / single battery emergency power supply unit for automatic testing in connection with a central monitoring station CHECK CONTROL BUS with the following fuctions: cyclic monitoring the charging procedure in intervals of < 5min. automatic execution of weekly 5min. function tests and automatic execution of yearly 40-120 min. termoperation test by the central monitoring station selective indication of test results and selective indication of failures (mains/battery/lamp/bus failure) to the central monitoring station. Special Version: with NiCd-batteries for application in areas with low ambient temperatures. Bitte Subject beachten to technical Sie die changes Hinweise im Technischen Anhang! 196