Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Similar documents
Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

7 Lighting Technology

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

Emergency Light Fitting for Fluorescent Lamps Series 6009

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

7 Lighting Technology

Sheet Steel Emergency Light Fitting Series 6018

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

LED Linear Luminaire Series EXLUX 6402

Linear Luminaire with LED Series EXLUX 6002

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Emergency Luminaire with LED Series EXLUX 6409/1

7 Lighting Technology

Linear luminaire with LED Series EXLUX 6002

Sheet-Steel Light Fittings Series 6014 / 6414

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Compact Sheet-Steel Light Fittings Series 6114

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

7 Lighting Technology

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Floodlight Series 6521/4

Compact Sheet-Steel Light Fittings Series 6114/1

Floodlight LED Series 6525

Floodlight LED Series 6125

Floodlight LED Series 6525

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Portable Lamps Series HS6145, HSL145

Plug and Socket Devices SolConeX 16 A Series 8570

Load disconnect switch Series 8146/5-V11

Tank Inspection Lights Series 6122

7 Lighting Technology

Terminal Boxes Series 8125

Floodlight Series 6121

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Safety Switches Series 8537

Ex UPS standard Series 8265

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Terminal Boxes Series 8125

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Position Switches Series 8074/2

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

Linear Luminaire for Fluorescent Lamps

Position Switches Series 8060/2

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Load and Motor Switches, Load-Break Switches Series 8544

Control switch/load disconnect switch Series 8008

Position Switches Series 8070/2

Battery Boxes Series 8316

I Ex-safety switches I

AVN. - Zone 2, 21, 22 - Lower maintenance costs - Easy to install - Suited to ambient temperatures of up to +55 C. Ex n. Stainless steel clips

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Metal Position Switch Series 8074

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

Load and Motor Switches, Load-Break Switches Series 8544

Fluorescent Lighting FE Series: Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Increased Safety

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Control Buttons / Switches for Panel Mounting Series 8003

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Easy and safe installation

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Load and Motor Switches, Load-Break Switches Series 8549

EX-REPAIR AND MAINTENANCE RECEPTACLES

110/127 V - 220/240 V BI-PIN HEAVY DUTY LUMINAIRES FOR ARMOURED OR NON-ARMOURED CABLE Fluo 2 x 36 W

Linear Luminaire with LED

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Linear fluorescent luminaire LED V-CG-S

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

10 Load and Motor Switchgear

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Lighting: Fluorescent Lighting RE Series: Recessed Fluorescent Lighting Fixtures, Standard and Emergency Back-Up Increased Safety

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Operating Instructions

Tubular Light Fitting with LED Series 6036

Main current switches >180 A are realized in metal enclosures. Internationally approved.

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

ATX FN Series Heavy Duty Nonmetallic Fluorescent Luminaires Standard and Emergency Back-Up. Zone 2-21 and 22

Operating Instructions

I Ex-Safety switches I

Control Buttons Series 8082

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

Linear fittings Fluorescent fitting EVN - Zones 2 & 22

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

Linear fittings EVN Fluorescent fitting - zones 2 & 22

I Ex-safety switches I

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

Linear fittings EVNL LED fitting - zones 2, & 22

Transcription:

www.stahl.de > For fluorescent lamps 2 x 18 W and 2 x 36 W > Electronic ballast with integrated emergency light electronics > Battery is integrated in the lamp enclosure > For emergency light mode 1.5 h > Intelligent charging technology > Enclosures in glass fibre reinforced polyester resin, lamp cover in shock-resistant polycarbonate > Enclosure closed by means of quick-action locks 12124E00 The battery-operated emergency light fittings of the can be used as emergency lighting according to EN 60598. ATEX / IECEx / GOST Zone 0 1 2 20 21 22 For use in x x WebCode 6608A Lighting /1

Selection Table Version Lamps Lamp activation Operating time test Order number Weight kg ECOLUX 6608 2 x 18 W 1 channel with 6608/322-8010-5247 3.860 Economy Zone 2, 22 without 6608/322-8010-5248 3.860 2 x 36 W 1 channel with 6608/342-8010-5247 5.680 without 6608/342-8010-5248 5.680 Order Number Supplement Through wiring without (standard) 6608/...-.0..-... with 6 conductors (only for 36 W) 6608/34.-.6..-... Cable entry Standard: M25 x 1.5 6608/...-..1.-... 1 Cable gland 2 Stopping plugs Special M20 or M25 of moulded material or metal to be specified with order 6608/...-..9.-... Note The lights are delivered without fluorescent lamps and assembly parts. These parts must be ordered separately! Explosion Protection Explosion protection Global (IECEx) Gas and dust IECEx PTB 09.0031X Ex na II T4 Ex td A22 IP66 T65 C Europe (ATEX) Gas and dust PTB 09 ATEX 2015 X E II 3 G Ex na II T4 E II 3 D Ex td A22 IP66 T65 C Certificates and approvals Certificates IECEx, ATEX, Russia (GOST R) Technical Data Electrical data Rated voltage Disconnection of the light Luminous Characteristics Lamps Lamp version Class according to LitG Measures for light guidance AC: 220... 240 V, 50 / 60 Hz Optionally when opening the lamp cover in case of a lamp fault 2 x 18 W 2 x 36 W 2-lamp without auxiliary reflector B21 when opening the locking mechanism on one of the quick-action locks, all poles of the voltage supply to the ballast are disconnected; contacts of the switching element with positive break, they are switched on again as soon as the lamp cover and the quick-action lock are closed. in case of a lamp fault, the electronic ballast disconnects the defective lamp from the power supply. 2-lamp with auxiliary reflector B31 Standard Broad reflective, internal reflector of light fitting painted white. Colour: Signal white RAL 9003; lateral glare is limited by the lamp diffuser cover. Special Auxiliary reflector (easily mountable), narrow-angle / wide-angle shining, aluminium anodised and polished. /2 Lighting

Technical Data Ambient conditions Standard operation - 20... + 40 C Battery operated functional at temperatures between - 5... + 40 C Mechanical data Degree of protection IP66 (IP64 with breather 8162) Protection class I(with internal PE connection) Material Enclosure Polyester resin, glass fibre reinforced, colour white, similar to RAL 9010 Lamp cover Polycarbonate, shock-resistant, as an option an aromatic-resistant paint can be used Seal Polyurethane foam gasket in the lamp cover Quick-acting locks Polyamide, glass fibre reinforced Assembly parts Polyester resin, glass fibre reinforced, white, similar to RAL 9010 Cover options Quick-acting locks to be opened by means of a screwdriver; lamp cover is equipped with a hinge Assembly / Installation Cable glands Connection option Through wiring Connection side: 1 cable gland M25 x 1.5 and 1 stopping plug M25 x 1.5 Opposite side: 1 stopping plug M25 x 1.5 (cable glands enclosed) Entry parts in moulded plastic (8161/8290): M20 Metal glands: M20, M25, Metal cable gland earthing via metal adapter plates Terminals L1, L2, L3, N, PE, L' (switched phase) 2.5 mm fine / single wire L1 = charging phase, must not be switched Lights available with internal through wiring, 6 wires; Cross-section 2.5 mm for max. 16 A only possible for 36 W Battery set Version NiCd battery Operating voltage 6 V Capacity 4 Ah Replacing the battery set Open the light, the battery can be replaced by means of plugs in the enclosure Emergency light electronics Design The emergency light electronics is installed in an enclosure together with the electronic ballast Operating modes Continuous circuit Interference suppression according to DIN EN 55015 Functional test The functional test lasts one minute and is carried out automatically once a week. Note: The first functional test is carried out 1 hour after putting into operation, that means after having connected the operating voltage to the terminals L1 and N. Light duration test of the The continuous function test for the emergency lighting is carried out every six months for a time emergency lighting period of 1 hour. During the test, the battery capacity is checked. Note: The first continuous function test is carried out 24 hours after putting into operation, that means after having connected the operating voltage to the terminals L1 and N. Function indicators LED display After putting into operation and after each connection to the power supply voltage, the LED lights up for 10 seconds (function control of the LED). The display indicates for 10 seconds whether the continuous function test is activated (LED flashes) or deactivated (LED off). Afterwards the display switches to the normal display mode and the following states are shown. Battery charge Emergency light mode Emergency light service time Switchover voltage Lighting power in case of emergency light mode LED green LED flashes LED off - Light is OK - Charging current flows - Light is OK - Functional test is active - Mains failure - Lamp or battery fault Intelligent battery management In the emergency light mode, only one lamp is used, see table 1.5 h for a battery capacity 4 Ah from mains to battery operation for U < 0.74 x U N from battery to mains operation for U > 0.80 x U N 18 W: 64 % 36 W: 32 % Lighting /3

Accessories and Spare Parts Designation Illustration Description Art. no. Weight Fluorescent lamp 04936E00 Two-pin cap d 26 mm Light colour: universal white 18 W 1350 Im kg 108952 0.100 36 W 3350 Im 58 W 5200 Im 108951 0.200 108950 0.220 Lamp cover Switch 05329E00 for lamp 18 / 20 W 124635 0.500 for lamp 36 / 40 W 124646 1.300 for lamp 58 / 65 W 124657 1.000 Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.025 Lamp holder 10809E00 Lamp holder for two-pin cap lamps G 13 107275 0.008 Mounting rail 05888E00 for a variable mounting distance of 1 pair 124894 0.210 05895E00 Mounting rail with a bracket Mounting bracket mounted on the mounting rail for a variable mounting distance of 1 pair 124901 0.300 Ring bolt M 8 05896E00 M8, direct mounting in insert nuts, 1 pair 115736 0.120 Fixation for stanchion mounting 05378E00 to mount the lamps as side-entry lamps using a tube with a length of 1300 mm, d 42 mm (for pipe clamp R 1 1 / 2 ) 109281 6.000 Top rail 05460E00 for ceiling suspension of the lamp, 1 pair 124908 0.230 Pipe clamp Mounting set for grid racks 05897E00 09402E00 with mounting rail for a variable mounting distance; Material: stainless steel R 1 1 / 4 (d 42 mm) 124913 1.140 R 1 1 / 2 (d 48 mm) 124891 1.160 R 2 (d 60 mm) 124898 1.300 for grid cable racks, with a cable diameter of 6 mm; 124905 1.560 with mounting rail for a variable mounting distance; Material: stainless steel Wall and ceiling mounting bracket 04361E00 mounted on a mounting rail for a variable mounting distance; Material: stainless steel Lamp can be swiveled in steps of 15 1 pair 124910 1.150 05898E00 /4 Lighting

Accessories and Spare Parts Designation Illustration Description Art. no. Weight kg Adapter plates for earth continuity when using metal glands; 1 x M20 x 1.5 1 piece 115815 0.070 05755E00 1 x M25 x 1.5 1 piece 1 x NPSM 1 / 2 1 piece 115818 0.070 115821 0.070 1 x NPT 3 / 4 1 piece 115824 0.070 2 x M20 x 1.5 1 piece 2 x M25 x 1.5 1 piece 115826 0.060 115828 0.060 Battery set 2 x NPSM 1 / 2 1 piece NiCd battery for 6608/3 4 Ah / 6 V 1 pc 115829 0.060 211520 1.100 13622E00 Reflectors 05324E00 for later installation, broad deep beam for lights with two lamps 18 W 117098 0.265 for lights with two lamps 36 W 117115 0.234 Cable gland of moulded material, series 8161 0.000 05864E00 8161/5-M20-13 8161/5-M20-13 1 piece 50 pieces 138518 0.012 138454 0.600 8161/5-M25-17 8161/5-M25-17 1 piece 50 pieces 138520 0.020 138456 1.000 Stopping plugs of moulded material, series 8290 04840E00 8290/3-M20 8290/3-M20 1 piece 100 pieces 143522 0.005 143543 0.500 8290/3-M25 1 pieces 143524 0.007 8290/3-M25 100 pieces 143544 0.700 Breathing gland for installation in lights; in moulded material; without counter nut 05703E00 Thread: M25 x 1.5 1 pc Thread: M25 x 1.5 20 pcs 138573 0.010 138576 0.200 Lighting /5

Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Dimensions Light 18 W 36 W L1 700 1310 L2 1) 400 800 L3 2) 340... 460 680... 920 1) fixed mounting distance 2) variable mounting distance Emergency light fitting ECOLUX 6608 Economy, 18 W, 36 W 04824E00 Pipe clamp 04717E00 Mounting set for grid racks 04822E00 Wall and ceiling mounting bracket 04716E00 Top rail 04833E00 04823E00 04715E00 04834E00 Fixation for stanchion mounting Ring bolt Mounting rail with a bracket Mounting accessories We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /6 Lighting