Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

Similar documents
Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

AZM 161SK 12/12RKED/TU 024

Datasheet - MV8H Y

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Technical data. Standards: IEC/EN BG-GS-ET-15

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Safety switches with separate actuator

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Safety door-handle system STS

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Safety switches with separate actuator

Solenoid interlock AZM 200 The non-contact interlock.

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Position Switches Series 8074/2

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal Industrial Switchgear.

Safety switches for hinged doors

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

Safety switches for hinges

Safety switches with solenoid and separate actuator

MS General Information Extended Product Type: MS

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Safety switches with solenoid and separate actuator

Safety Sensor CSS 180 Product Information

LR-LX-LK-LW Safety Switches with separate actuator

Door locking devices. 4 Schmersal Industrial Switchgear

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Position Switches Series 8070/2

Thermal overload relay TF140DU and TF140DU-V1000

Safety switches for hinged doors

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Load disconnect switch Series 8146/5-V11

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

Position switches FD series

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

Safety Switches with Separate Actuator SKC

Position Switches Series 8060/2

Operating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content

Operating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content

Load and Motor Switches, Load-Break Switches Series 8544

Load and Motor Switches, Load-Break Switches Series 8544

Thermal overload relay TF65 and TF96

Safety switches / Position switches / Command devices

Electronic overload relay EF65, EF96 and EF146

SERIES Z/T236. Safety-Rated, Positive-Break Miniature DIN Limit Switches. Features & Benefits. Description. Typical Applications ORDERING GUIDE

Electronic overload relays EF205 and EF370

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

FL series position switches

Solenoid Locking Safety Switches

Fuse switch disconnectors

SFS-UFS Single Foot Switches

Safety rope switches with reset for emergency stop

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Control switch/load disconnect switch Series 8008

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Load and Motor Switches, Load-Break Switches Series 8549

Standard Interlock Safety Switches

vertical fuse switch disconnectors

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Safety switches with solenoid and separate actuator

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Safety rope switch without reset for simple stop

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Installation and Operating Instructions

Standard Interlock Safety Switches

Automation // SYSTEMATIC CONTROL SWITCHGEAR. Emergency pull-wire, Pull-wire, Belt-alignment, Slack-wire switches

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

SNAP ACTION SWITCHES type SAS-00, SAS-03

BETA Switching Switches and Light Indicators

HS1C Interlock Switches with Solenoid

Safety rope switch with reset for emergency stop

Motorised and automatic transfer enclosed switchess

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

LK Position Switches TECHNICAL DATASHEET.

Switches with manual reset

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Safety Switches Series 8537

Solenoid Locking Safety Switches

Safety Switches with Separate Actuator, Plastic Housing

Single foot switches - PX and PA series

Operating instructions Solenoid interlock AZM 170

Protection components

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.


M-0. M-0... series control, monitoring and signalling devices. Ex e

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Selective main circuit breakers S 750 series Technical Data

Transcription:

Datasheet - TV8S 521-02/20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521 Metal enclosure Good resistance to oil and petroleum spirit Mounting independent of hinge 92 mm x 81,5 mm x 27 mm Variable mounting on hinged side Rail-mounting possible with slot nuts 2-channel, alternating monitoring Actuator shaft can be turned 360 For left or right hinged doors Push-in system (toothed shaft) 2 cable entries M 16 x 1.5 2 switches in one enclosure (Minor differences between the printed image and the original product may exist!) Ordering details Product type description TV8S 521-02/20Z Article number 1138422 EAN code 4030661281278 When ordering, first the desired safety switch should be selected and then the appropriate universal joint; for universal joint K1, additionally the corresponding F or L hinge Approval Approval BG CCC USA/CAN Classification Standards EN ISO 13849-1 B10d Opener (NC) 20.000.000 Mission time 20 Years notice Global Properties

Product name TV8S 521 Standards EN 60947-5-1, BG-GS-ET-15 Compliance with the Directives (Y/N) Yes Materials - Material of the housings Aluminium - Material of the contacts Silver Housing coating painted Weight 268 g Mechanical data Design of electrical connection Screw connection Cable entry M 16 x 1.5 2 Cable section - Min. Cable section 1 x 0,75 mm² - Max. Cable section 1 x 1.5 mm² Mechanical life > 1.000.000 operations Switching frequency max. 1000 /h Shaft bore Inner toothing 10 mm Positive break angle 14 Positive break torque 8 Ncm notice All indications about the cable section are including the conductor ferrules. Ambient conditions Ambient temperature - Min. environmental temperature 25 C - Max. environmental temperature +70 C Protection class IP67 Electrical data Design of control element Normally open contact (NO), Opener (NC) Switching principle Creep circuit element Number of auxiliary contacts 0 piece (S1), 2 piece (S2) Number of safety contacts 2 piece (S1), 0 piece (S2) Rated impulse withstand voltage U imp 4 kv Rated insulation voltage U i 250 V Thermal test current I the 10 A Utilisation category AC-15: 230 V / 4 A, DC-13: 24 V / 1 A Max. fuse rating 6 A gg D-fuse ATEX Explosion protection categories for gases Explosion protected category for dusts None None Dimensions Dimensions of the sensor - Width of sensor 92 mm - Height of sensor 81.5 mm

- Length of sensor 27 mm notice Universal joint to compensate axial displacement Switching point subsequently adjustable using hinge L Diagram Note Diagram positive break NC contact active no active Normally-open contact Normally-closed contact Switch travel diagram Notes Switch travel diagram Contact closed Contact open Setting range Break point Positive opening sequence/- angle VS adjustable range of NO contact VÖ adjustable range of NC contact N after travel Ordering code TV8S 521-(1)

(1) 11/11 Switch insert 1: 1 Normally open contact (NO) / 1 Opener (NC) Switch insert 2: 1 Normally open contact (NO) / 1 Opener (NC) 02/20 Switch insert 1: 2 Opener (NC) Switch insert 2: 2 Normally open contact (NO)

Dimensional drawing (basic component) Dimensional drawing (miscellaneous) Application System components Accessories 1138412 - UNIVERSAL JOINT K1 Factory-mounted pins Universal joint to compensate axial displacement 1138413 - adjustable hinge L

1138414 - Fixed hinge F K.A. Schmersal GmbH, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am 10.10.2011-10:17:23h Kasbase 1.5.5 DBI