Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

Similar documents
Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

AZM 161SK 12/12RKED/TU 024

Datasheet - MV8H Y

Technical data. Standards: IEC/EN BG-GS-ET-15

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Safety door-handle system STS

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Solenoid interlock EX-AZM About this document. Content

Safety switches with separate actuator

Safety Switches with Separate Actuator SKC

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal Industrial Switchgear.

Safety switches with separate actuator

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

LR-LX-LK-LW Safety Switches with separate actuator

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Position Switches Series 8074/2

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Solenoid interlock AZM 200 The non-contact interlock.

Position switches FD series

Safety switches for hinged doors

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Safety switches for hinges

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Door locking devices. 4 Schmersal Industrial Switchgear

Control switch/load disconnect switch Series 8008

Safety switches with solenoid and separate actuator

Position Switches Series 8070/2

Operating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content

Safety switches for hinged doors

Position Switches Series 8060/2

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

Safety switches / Position switches / Command devices

Safety switches with solenoid and separate actuator

MS General Information Extended Product Type: MS

FL series position switches

Single foot switches - PX and PA series

Load disconnect switch Series 8146/5-V11

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

LK Position Switches TECHNICAL DATASHEET.

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Safety rope switches with reset for emergency stop

Safety rope switch with reset for emergency stop

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

Position switches FC series

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Switches with manual reset

Safety rope switch without reset for simple stop

Thermal overload relay TF140DU and TF140DU-V1000

SFS-UFS Single Foot Switches

Operating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content

Standard Interlock Safety Switches

Fuse switch disconnectors

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Position switches FR series

Operating instructions Solenoid interlock AZM 170

Position switches FR series

Load and Motor Switches, Load-Break Switches Series 8544

Load and Motor Switches, Load-Break Switches Series 8544

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Safety Switches Series 8537

Control Buttons / Switches for Panel Mounting Series 8003

Thermal overload relay TF65 and TF96

Pendant control stations 6

Automation // SYSTEMATIC CONTROL SWITCHGEAR. Emergency pull-wire, Pull-wire, Belt-alignment, Slack-wire switches

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Electronic overload relay EF65, EF96 and EF146

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Electronic overload relays EF205 and EF370

Safety Switches with Separate Actuator, Plastic Housing

CI-TI Contactors and motor starters Types CI 61 - CI 98

Installation and Operating Instructions

Safety switches with solenoid and separate actuator

Prewired position switches FF series

Floor and fine adjustment switches

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Installation and Operating Instructions

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

FOOT SWITCHES

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Load and Motor Switches, Load-Break Switches Series 8549

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Safety Sensor CSS 180 Product Information

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

Single foot switches PX and PA series

Solenoid Locking Safety Switches

YFC. Limit switch. Ex d. 24 operating head types

Transcription:

Datasheet - AZ 3350-12ZUEK Safety switch with separate actuator / AZ 3350 Metal enclosure Latching handle Long life 40,5 mm x 114 mm x 38 mm High level of contact reliability with low voltages and currents 1 Cable entry M 20 x 1.5 (Minor differences between the printed image and the original product may exist!) Ordering details Product type description AZ 3350-12ZUEK Article number 1214053 EAN code 4030661397580 To order, first choose the desired safety switch and then the door handle system Approval Approval BG USA/CAN CCC Classification Standards EN ISO 13849-1 B10d Normally-closed contact (NC) 2.000.000 B10d Normally open contact (NO) 1.000.000 - notice at 10% Ie and ohmic load Mission time 20 Years notice

Global Properties Product name AZ 3350 Standards EN 60947-5-1, BG-GS-ET-15, EN 1088 Materials - Material of the housings Aluminium - Material of the contacts Silver Housing coating painted Weight 250 g Recommended actuator AZ 3350-B1, AZ 3350-B5, AZ 3350-B1R, AZ 3350- B5R, AZ 3350-B6, AZ 3350-B6H Mechanical data Design of electrical connection Screw connection Cable section - Min. Cable section 0,75 mm² - Max. Cable section 2.5 mm² Mechanical life 1.000.000 operations higher Latching force (Y/N) No Shearing force 15.000 N Positive break force 5 N for each NC contact fitted positive break travel 10.7 mm Door hinge left notice All indications about the cable section are including the conductor ferrules. Ambient conditions Ambient temperature - Min. environmental temperature 30 C - Max. environmental temperature +90 C Protection class IP67 to IEC/EN 60529 Electrical data Design of control element Normally open contact (NO), Opener (NC) Switching principle Slow action with overlapping contacts Number of auxiliary contacts 1 piece Number of safety contacts 2 piece Rated impulse withstand voltage U imp 4 kv Rated insulation voltage U i 250 V Thermal test current I the 10 A Utilisation category AC-15: 230 V / 4 A, DC-13: 24 V / 4 A Max. fuse rating 6 A gg D-fuse ATEX

Explosion protection categories for gases Explosion protected category for dusts None None Dimensions Dimensions of the sensor - Width of sensor 40.5 mm - Height of sensor 114 mm - Length of sensor 38 mm Included in delivery Mounting plate for safety switch Actuator incl. mounting plate emergency handle Diagram Note Diagram positive break NC contact active no active Normally-open contact Normally-closed contact Ordering suffix The applicable ordering suffix is added at the end of the part number of the safety switch. Order example: AZ 3350-12ZUEK-1637...-1637 0,3 µm gold-plated contacts Ordering code AZ 3350-(1)-(2)-(3) (1) 03ZK 3 Opener (NC) 12ZUEK 1 Normally open contact (NO) / 2 Opener (NC) (2) 1637 gold-plated contacts (3) U90 Actuating head rotated by 90 for Door hinge left

http://www.schmersal.net/datenblatt?lang=en&produkt=kax734241rcukli2rnw422427... 10/10/2011 U270 Actuating head rotated by 270 for Door hinge right Dimensional drawing (basic component)

Dimensional drawing (miscellaneous) Dimensional drawing (miscellaneous) Application System components Actuator 1214073 - AZ 3350-B6H

1214069 - AZ 3350-B6 1214072 - AZ 3350-B5R 1214068 - AZ 3350-B1R 1214067 - AZ 3350-B5 Particularly suitable for sliding doors 1214066 - AZ 3350-B1 Particularly suitable for sliding doors Door-handle system AZ 3350-STS30 Latching handle Accessories Lockout tag SZ 415 Suitable for mounting inside and outside of the hazardous area To prevent inadvertent closing, e.g. during maintenance

For complex plant Prevents actuation of the switch Lockout tag with 3 circular holes Centring device Pre-positioning The actuator is independent from the centring device. Smooth insertion or retraction of the actuator K.A. Schmersal GmbH, Möddinghofe 30, D-42279 Wuppertal The data and values have been checked throroughly. Technical modifications and errors excepted. Generiert am 10.10.2011-10:23:46h Kasbase 1.5.5 DBI