Hopkinsons Fig 9050M & 9151M Issue 1982 ELECTRIC ACTUATOR Modulating Duty

Similar documents
Hopkinsons Fig 9151 Issue pre 1980 VALVE ACTUATOR

Hopkinsons Fig 9052 VALVE ACTUATOR

Hopkinsons Fig 9051 VALVE ACTUATOR

E L L I O T T 14M, 18M & 24M. Contents OPERATORS INSTRUCTION HANDBOOK FOR THE HIGH SPEED SHAPING MACHINES MODELS. Also COMPONENT PARTS LIST.

EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions

Q Range electric direct-drive quarter turn valve actuators. Instruction manual


Valtek Auxiliary Handwheels and Limit Stops

L-120 SERIES INSTRUCTION AND MAINTENANCE MANUAL

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

USER INSTRUCTIONS. Limitorque L Actuator. Installation Operation Maintenance. Experience In Motion FCD LMENIM A4 06/15

walton TEMPERATURE CONTROL SYSTEMS Pneumatically Operated (Rotary)

Twin Power. Manual. Pneumatic Multiturn actuator in Standard and ATEX design WARNING! WARNING! Mounting. Assembly example

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

Contents. AQ Instruction Manual

Gearbox Installation Manual

INSTRUCTION MANUAL ACTUATOR CLASSE I TYPE MA, MB

Operation & Instructions Manual SA 3 - SA 100 SAR 3 - SAR 100

MUELLER ECCENTRIC PLUG VALVE

EL5600 Series Electric Linear Actuators

P3 3-STOP POSITIONER IOM

Driver Driven. InputSpeed. Gears

INSTRUCTION MANUAL ACTUATOR CLASSE II TYPE MAS4

Gearbox Instruction Manual

OPERATION INSTRUCTONS MODEL SG 05.1 SG Quarter-Turn Actuators

Westingh'ouse Steam Turbines-I. B (Rev. 3) GOVERNOR, GOVERNING VALVE

Gearheads H-51. Gearheads for AC Motors H-51

Ch 4 Motor Control Devices

N-Line Valves. Surface Stepping Actuators

Specific information for calibre 3603

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

DeZURIK MANUAL G-SERIES ACTUATORS USED ON PEC ECCENTRIC VALVES

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

CENTAC Inlet and Bypass Valve Positioners

ROMpak Series. Keeping the World Flowing. Installation Manual. Valve Actuators

CK Range. Keeping the World Flowing. Spare Parts Manual. Modular Design Electric Valve Actuators

AEL5 Series Electric Linear Actuators

Motor-drive mechanism, type BUL. Technical guide

ANDCO Eagle Actuator Instruction Manual

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Main Governor and Speed Changer

J125. Service Regulator Inlet Pressure up to 8.6 bar

James Hamilton Electrical Pty Ltd (Inc in Qld) A.C.N trading as. Power Drive Systems. Generator Control Specialists

Operating & Maintenance Instructions Thermobend Elite Range

Tips & Technology For Bosch business partners

PHYSICS MCQ (TERM-1) BOARD PAPERS

Installation & Operation Manual

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

CONTROL VALVES. Installation, Maintenance & Operating Instructions. Read these instructions carefully before installation or servicing.

Pneumatic Rotary Actuator Type 3278

11/23/2013. Chapter 13. Gear Trains. Dr. Mohammad Suliman Abuhiba, PE

AWT RANGE CONTROL AND MONITORING F ACILITIES. Publication E320E issue 10/02

Type SAM-01 to Type SAM-52 Electric Actuators. Type SAM-20, 30 mm rated travel, 6 kn thrust. Mounting and Operating Instructions EB 8330 EN

Instruction Manual for Barber-Colman Series EA Electric High Torque Actuators

Series 100 Slam Shut Valve

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

Operating Instructions ROCO Butterfly Valve with SKG Slider-crank Mechanism, with Electric Multi-turn Actuator

Sub Section Title Page No. 1 Introduction 3. 2 Significant Equipment Detail 3. 3 Installation Guidelines 4. 4 Routine Maintenance 4

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

Product features & Overview. KA Linear actuators

Quarter Master Chief Series 92 Actuator

490 Series Actuators. 490 Series. Contents. Introduction

Title: Illustrated troubleshooting and set-up guide for Kinetrol EL Positioners

This file is available for free download at

ASR WORMWHEEL UNLOCK DEVICE. ASR - Worm Speed Reducers types RS and RT

Tooling Assistance Center

POWER METER. my2010 (c)

HOLINGER SF GEARBOX MANUAL

Lecture (7) on. Gear Measurement. By Dr. Emad M. Saad. Industrial Engineering Dept. Faculty of Engineering. Fayoum University.

COLOMBO FILIPPETTI SPA

INSTRUCTIONS FOR USE SPUR GEAR OPERATORS. E. EBONG issue 4 SPUR

Hi-T Pigalert TM INSTRUCTION MANUAL INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Special 45-rpm Changers

Quarter Master Series 94 Actuator

The chronograph calibres CHRO PC 17 jewels CHRO C12 PC 17 jewels CHRO C12 PC AMPM GMT 17 jewels CHRO PC CAL 17 jewels

FRICK TIMBER TIGER SAWMILLS SIZES: 0 0C

K Range. High Torque Electric Valve Actuators. Redefining Flow Control

Maintenance Information

4.0 OPERATION Type ITH-T Relay

GEAR CONTENTS POWER TRANSMISSION GEAR TYPES OF GEARS NOMENCLATURE APPLICATIONS OF GEARS VELOCITY RATIO GEAR TRAINS EXAMPLE PROBLEMS AND QUESTIONS

Service Manual Gulf Stream Electronic Full Wall Slide Systems

VG7000 Series Bronze Control Valves

Operating Instructions Thread Rolling Heads F 001, F 01, K 01-1

Infinit-Indexer Phase Adjuster. HDI Series. Total Motion Control. Harmonic Drive gear

SD Bendix ET-2 Electronic Treadle DESCRIPTION OPERATION

ROM Series. Keeping the World Flowing. Installation Manual. Valve Actuators

AE Installation Operation & Maintenance Instructions

12 Series Linear Electric Actuator Installation, Operation & Maintenance Manual

INDEX. PAGE Adjustment mechanism for radial position of block on rotating

MGA Twin Cam Engine Assembly.

GARRARD MODEL 401 TRANSCRIPTION TURNTABLE. Instruction Manual GARRARD ENGINEERING LIMITED NEWCASTLE STREET SWINDON WILTSHIRE

Technical Information Review

S 1525-G Industrial ADJUSTMENT MANUAL

Sub Section Title Page No.

OPERATING INSTRUCTIONS AND SERVICE MANUAL

Series A Electric Linear Actuators

SALES DIVISION NETWORK TECHNICAL INFORMATION WORKSHOP MANUAL MOTOR ENGINE

Question 8 Engineering Higher Level

SUREPOWR TM SERIES -SURE 49 FIELD INSTALLATION INSTRUCTIONS

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

Transcription:

Excellent Engineering Solutions Standard Operating & Maintenance Instructions Hopkinsons Fig 9050M & 9151M Issue 1982 ELECTRIC ACTUATOR Modulating Duty SECTIONAL ARRANGEMENT OF FIG. 9050M & 9151M ACTUATOR (WITHOUT SWITCHGEAR) FIG. 9050M (3.4 FIG 10) & 9151M (3.4.1 FIG 11) HOP 9050M & 9151M Issue 1982/May 2012

Index Section 1 1.1 General Page 4 1.2 Motor and Gear Train Drive Page 4 1.2.1 Output Drive Page 4 1.3 Manual Operation Page 5 1.4 Torque Limiting Device Page 5 1.5 Limit Switch Assembly Page 5 1.6 Continuous Mechanical Indicator Unit Page 6 1.6.1 Valve Position Transmitter Page 6 Section 2 2.1 Alternating Current Page 7 2.2 Limit Switch and Setting up Procedure Page 7 2.2.1 Replacement of Micro Switches Page 8 2.3 Torque Switch Assembly Page 8 2.4 Fitting Direct Mounted Actuators Page 9 2.5 Fitting Pedestal Mounted Actuators Page 10 2.6 Lubrication Page 10 2.7 Spares Page 10 2.8 Data Sheet 70275 Page 11 Drawings Arrangement of Fig. 9050M Rotary Actuator (Fig. 1) Page 13 Arrangement of Fig. 9151M Rotary Actuator (Fig. 2) Page 14 Arrangement of Fig. 9050M Rotary Part Turn Actuator in Conjunction with a Quadrant Gearbox (Fig. 3) Page 15 Arrangement of Fig. 9151M Rotary Part Turn Actuator in Conjunction with a Quadrant Gearbox (Fig. 4) Page 16 Arrangement of Fig. 9050M Rotary Lever Arm Actuator in Conjunction with an Intermediate Gearbox (Fig. 5) Page 17 Arrangement of Fig. 9151M Rotary Lever Arm Actuator in Conjunction with an Intermediate Gearbox (Fig. 6) Page 18 Arrangement of Fig. 9050m Linear Actuator 1 1 / 2 Max. Travel (Fig. 7) Page 19 Arrangement of Fig. 9050M Linear Actuator 3 1 / 2 Max. Travel (Fig. 8) Page 20 Arrangement of Fig. 9151m Linear Actuator 3 1 / 2 Max. Travel (Fig. 9) Page 21 2 Weir - First choice for power and industrial protection

Index continued Sectional Arrangement of Fig. 9050M Actuator with Rotor/Stator Unit (Fig. 10) Page 22 Sectional Arrangement of Fig. 9151M Actuator with Rotor/Stator Unit (Fig. 11) Page 23 Sectional Arrangement of Figs. 9050M & 9151M Flanged/Geared Motors (Fig. 12) Page 24 Sectional Arrangement of Figs. 9050M & 9151M Rotary/Linear Convertors (Fig. 13) Page 25 Sectional Arrangement of Typical Part Turn Operator (Fig. 14) Page 26 Sectional Arrangement of Typical Lever Arm Operator (Fig. 15) Page 27 Torque Switch Assembly for Figs. 9050M & 9151M Actuators (Fig. 16) Page 28 Arrangement of Limit Switch for Figs. 9050M & 9151M Actuators (Fig. 17) Page 29 Arrangement of Mechanical Indicator Unit and Valve Position Transmitter for Figs. 9050M & 9151M Actuators (Fig. 17) Page 29 Arrangement of Figs. 9050M & 9151M Actuators Pedestal Mounted (Fig. 18) Page 30 Contact Details Page 31 3 Weir - First choice for power and industrial protection

Hopkinsons Fig 9050 ELECTRIC ACTUATOR Section 1 1.1 GENERAL The actuator consists of a rotor/stator unit or a flange mounted motor depending on application, driving an output shaft through a single stage worm reduction, which incorporates an automatic mechanical device for changing the drive from manual to power. The actuator includes a travel limit switch unit and a torque switch unit and is of totally enclosed weatherproof construction, suitable for mounting at any angle or inverted. The actuator has 4 major drive variations:- 1. Rotary Multi-turn (See Figs. 1 and 2) 2. Rotary Part Turn in conjunction with a quadrant gearbox (See Figs. 3 and 4) 3. Rotary Lever Arm in conjunction with an intermediate gearbox (See Figs. 5 and 6) 4. Linear (See Figs. 7, 8 and 9) Other drives are available on request. 1.2 MOTOR AND GEAR TRAIN DRIVE A. C. 3 phase rotor/stator unit and flange mounted motors are of squirrel cage design. Class 'F' insulation is provided as standard. The windings are terminated on stud type terminals in the actuator terminal box for stator/rotor unit and in the motor terminal box for flange mounted motor. Motor winding thermostats or thermistors are provided to protect the motor against burn out. The stator is mounted in a housing forming an integral part of the actuator housing and the rotor is mounted directly onto the wormshaft which is mounted on needle roller bearings. (See Figs. 10 and 11). The flange mounted motor is mounted on an adaptor to the actuator and the drive is via a sliding coupling to the wormshaft. (See Fig. 12). The output shaft bearings are located in the main housing and the output shaft assembly is a direct drive i.e. no lost motion. 1.2.1 OUTPUT DRIVE The output shaft is connected to a drive sleeve, the drive sleeve being screwed for rotary multiturn applications i.e., rising spindle. The linear drive is similar to the multi-turn drive with a screwed sleeve driving a spindle, which is located in a mounting base complete with bonnet mounting yoke, an anti-rotation device, and adjustable mechanical stops. (See Fig. 13). The rotary part turn and rotary lever arm both use a drive sleeve, keywayed to suit the input 4 Weir - First choice for power and industrial protection

shaft of an intermediate or quadrant gearbox. The gearbox consists of an input adaptor, and an enclosed worm and wormwheel with adjustable mechanical stops. (See Fig. 14). The wormwheel bore is keywayed to provide the output drive either direct or through a shaft and lever arm (see Fig. 15). 1.3 MANUAL OPERATION The actuator is equipped with a handwheel to operate in event of power failure. The handwheel is easiiy engaged with the output shaft by moving the hand/auto lever from right to left and at the same time slowly turning the handwheel. An automatic device is incorporated which transfers the drive from manual to power when the motor rotates. As the sliding clutch is withdrawn completely from manual before engaging power drive the operator is ensured complete safety should the actuator be started during hand operation. IMPORTANT It is impossible to engage power drive by using the hand/auto lever, and no attempt should be made to force the lever to power position. The sliding clutch is mounted on the splined output shaft and a compression spring ensures that the dog teeth on the underside are fully in mesh with the dog teeth on the top side of the wormwheel thus transmitting the drive from wormshaft to the wormwheel, from the wormwheel to the sliding clutch and from the sliding clutch to the output shaft, and from the output shaft to the drive sleeve. The hand/auto lever operates a lever and roller which makes contact with the sliding clutch in order to lift it out of engagement with the wormwheel and into engagement with the dog teeth on the handwheel (See Figs. 10 and 11). The hand/auto lever is maintained in the hand position by 2 spring loaded catch levers. To return to power operation the motor is energised and as the wormshaft rotates, 2 pawls fitted into the wormwheel strike the 2 spring loaded catch levers which release the hand/ auto lever allowing it and the sliding clutch to return to the auto position. 1.4 TORQUE LIMITING DEVICE The wormshaft of the actuator is capable of axial movement against a spring pack assembly. The design of the spring pack is such that a limited deflection is permitted allowing axial movement of the wormshaft in either direction corresponding to 40% to 120% rated output torque of the actuator in the opening or closing direction (see Fig. 16). 1.5 LIMIT SWITCH ASSEMBLY The limit switch and indicator units are mounted on plates which embody an indicator take-off spindle from the limit switch drive gear. 5 Weir - First choice for power and industrial protection

The complete assembly is fitted to the end of the actuator, opposite to the motor, the cross pin of the limit switch take-off spindle and a slot in the limit switch drive spindle forming the coupling for the gear drive from the actuator output shaft (see Fig. 17). The standard limit switch assembly comprises 4 'open' position and 4 'close' position micro switches of which only 3 'open' position and 2 'close' position micro switches are wired to the actuator terminal board. The additional switches may be wired to the actuator terminal board depending upon customers requirements. Each bank of lever-roller actuated switches are operated by a cam positively driven by the hunting tooth gear train. Switches 1, 2 and 3 are designed to operate simultaneously with switch 4 operating last by means of a small step on the cam. As such, switch 4 should always be used as the actuator travel limit switch. Intermediate position switches or additional open and close switches may be fitted when required by the addition of another limit switch assembly (see Fig. 17). The hunting tooth gear trains are so arranged that each bank is independently adjustable to provide any limit switch setting from zero to 100 turns in steps of 0.1 of a turn. Special assemblies can be provided to count from zero to 1000 actuator turns in adjustable steps of 1 turn. The limit switch gear train consists of a drive spindle driven by internal actuator gears, to a spur gear pinned to the drive shaft, which drives the first stage spur wheel and hunting tooth wheel. The latter being located and driven by the spur wheel with a double pentagon recess in the hunting tooth wheel which can be located in any of ten positions on the pentagon spigot of the spur wheel. These positions correspond to the numerals on the hunting tooth flange. The drive is transferred to the hunting tooth pinions through three stages of hunting tooth wheels and then back to the final hunting tooth pinions which has an integrally moulded spur gear which drives the cam. A spring on the hunting tooth gear locked together in the normal driving or set position but permits them to be separated for initial setting (see Fig. 17). 1.6 CONTINUOUS MECHANICAL INDICATOR UNIT The indicator unit consists of two plates separated by pillars, input and output spindles, change gear, spur gears, index plates, pointer and pointer spindle. An indicator unit supplied with an actuator includes change gears of the correct ratio for the number of output turns of the actuator. No adjustment is required to the indicator other than setting the pointer to the 'shut' index of the scaie with the vaive in the full shut position after setting the limit switch and adjusting the index plates if necessary (see Fig. 17). 1.6.1 VALVE POSITION TRANSMITTER A transmitter, used for the purpose of remote indication and/or feedback control, is usually fitted in conjunction with milli-amp position transmitter when required. (see Data Sheet 70275). 6 Weir - First choice for power and industrial protection

To prevent damage to the transmitter fitted to an actuator which has not been direct mounted to a valve and commissioned by Hopkinsons, the final drive gear attached to the transmitter shaft should be left out of mesh with the other indicator gears. The final drive gear should be left to the commissioning engineer to couple up and adjust after setting the limit switches. (See Fig. 17). Section 2 2.1 ALTERNATING CURRENT For A.C. 2 and 3 phase. It is very important to ascertain that the direction of travel of the valve corresponds to the 'open' and the 'close' button of the controller. Carefully check the direction of travel of the valve with the movement of the controller by having the valve in mid-position. Then press the 'open' or 'close' operating button and immediately after that stop the actuator and then ascertain whether the valve has moved to correspond to the button which was operated. If the valve has travelled in the opposite direction, reverse any two of the supply leads in the contactor, then restore electrical supplies and repeat the procedure. 2.2 LIMIT SWITCH AND SETTING UP PROCEDURE The limit switch assembly of an actuator fitted direct on to a valve is set for the correct number of turns before despatch and should not be disturbed. Pedestal type actuators or actuators for fitting direct on to valves at site are despatched with each switch bank set at 50 turns so that any mal-operation of the handwheel before the actuator is coupled or fitted to the valve should not disturb the correct relationship of cams to rollers. After coupling or fitting the actuator to the valve remove the limit switch cover, taking care not to damage or misplace the rubber 'O' ring seal. Hand operate the valve to within 1% of the full shut position and observe that the limit switch cams are in the correct position i.e. switch rollers at the top of the cam with the black setting line on the cam visible and under the rollers. Set the close bank hunting tooth wheels to 00.0 and then operate the actuator handwheel 1/4 of a turn more and observe that the limit switch cam moves away from the micro switch rollers and allows the micro switches to operate. Check that switches have operated using a suitable measuring instrument. On a parallel slide valve, check that 1/16" (1.6 mm) to 1/8" (3.2 mm) clearance exists between the bottom of the valve stop and the shoulder of the valve pillars. If this clearance is not observed re-adjust limit switch setting as above. Then operate the valve to within 1% of the full open position and set the open bank hunting tooth wheels to 00.0 and repeat the setting procedure. If for any reason the cam is not in the correct position it can be easily adjusted by separating and rotating the hunting tooth wheel, which registers 10s turns indicated by the continuous white line on barrel. One complete revolution will cause the spur wheel which is moulded to the pinion to rotate, and this can be assisted by hand, rotating the spur wheel 7 Weir - First choice for power and industrial protection

causes the operating cam to move 144. Continue until such time as the black line on the cam is positioned under the micro switch rollers. NOTE: Always rotate the hunting tooth wheel in an ascending order i.e. 1, 2, 3, etc. There is only one correct position of the black line allowing correct re-engagement of the hunting tooth wheel with its mating spur wheel. In certain inaccessible site locations it may be difficult to observe that the black line on the operating cam is in the correct position. This can be checked using a multimeter or bell and battery across the terminals corresponding to the open and close travel limits. (Normally open limit is numbered 3 and 5 and close limit 4 and 6). Ascertain that connections have been made correctly to limit switch. With the valve in mid travel position a circuit should exist between terminals 3 and 5, and 4 and 6. If this is not the case the cam is in the wrong position. Now set the intermediate 'open' and 'close' bank limit switches (when fitted) to the correct number of turns from the respective zero at which these switches are required to operate. Operate the actuator and check operation of all switches, indicators etc., replace the limit switch cover and 'O' ring seal with care. 2.2.1. REPLACEMENT OF MICRO SWITCHES It is recommended that adjustments or repairs that are carried out on site are restricted to the replacement of micro switches only. To do this the following procedure must be followed to ensure correct future operation. (i) Isolate the actuator from the electrical supplies, remove faulty limit switch assembly to workshop. (ii) Set the limit switch assembly to mid-travel, i.e. cams depressing switch plungers. (iii) Remove the micro switch securing nuts and rods, replace faulty switches and re-tighten the rods ensuring that all the switches are pulled away as far as possible from the operating cam. A minimum clearance of 0.010" (0.254mm) should exist between the cam and the switch rollers when the black line on the cam is under the rollers and the rollers are hard up to the switch moulding. Check operation of assembly to ensure that the drive spindle can be turned by hand and that the switches can be operated freely. (iv) Replace limit switch in actuator, re-connect and follow setting up procedure. 2.3 TORQUE SWITCH ASSEMBLY The actuator is fitted with a torque switch assembly which incorporates 'open' and 'close' torque switches which are fitted with adjusting features easily set to limit the actuator torque in increments of 20% within the indicated range. The torque switch assembly is spigot mounted on the actuator housing and the open and close pinions are engaged with the drive sleeve fitted on the end of the wormshaft. Torque indication in terms of axial displacement of the wormshaft is transmitted via the pinions to the 'open' and 'close' torque switch operating spindles. 8 Weir - First choice for power and industrial protection

Withdrawal of the operating spindle by means of the knurled knob permits the adjusting pointer to be set in any 5 positions from 0.4 to 1.2 (40%-120%) output torque. The operating spindles are spring loaded and therefore are held in position after re-engaging with the drive sleeve. The switch is normally tripped with the circuit closed and retained in this position by the switch lever and torsion spring. The switch is re-set and the circuit opened at the set torque figure by the action of the cam attached to the pinion spindle. (see Fig. 16). The actuator torque switches are normaily set at works to suit the particular application, therefore no adjustment should be necessary. N.B. If the predetermined torque switch settings or the actuator application is not known, the torque switches will be set at a minimum and left to the commissioning engineer to set. In some instances 'non-adjustable' torque switches are specified and in these cases the torque switches are pre-set at the factory and further adjustment on site is not possible. The torque switches operate independently and do not reset until actuator is reversed. 2.4 FITTING DIRECT MOUNTED ACTUATORS Valves which are to be fitted with direct mounted actuators at site are fitted with a circular adaptor plate secured to the valve by the pillar nuts. If a standard hand operated valve is to be motorised by means of a direct mounted actuator, remove the existing handwheel, gearing (when fitted) sleeve and bridge, leaving the valve pillars and spindle only for application of the actuator. Remove the circular adaptor plate from the base of the actuator and fit this item on the valve pillar ends and secure by means of the existing pillar nuts. Do not remove any covers at this stage but engage manual operation in preparation for fitting to the valve. Sling the actuator by means of overhead tackle and carefully lining up the actuator with the valve spindle axially and radially, lower the actuator on to the valve until the drive sleeve begins to engage the valve spindle. Rotate the handwheel in the opening direction, and, at the same time, gradually lower the actuator until the base face or distance pieces is/are flush with the top face of the adaptor flange. Fit the nuts to the mounting studs and secure. A grease gun nipple is provided for lubricating the sleeve and valve stem this should be charged with grease when commissioning with the valve in the full open position to the specification, referred to in paragraph 2.6. Set limits and torque switches as described previously. 9 Weir - First choice for power and industrial protection

2.5 FITTING PEDESTAL MOUNTED ACTUATORS First ascertain that the valve is in the full shut position i.e. on a parallel slide valve that the stop is 1/16" (1.6 mm) to 1/8" (3.2 mm) clear of the lower shoulder of the valve pillars. Connect the valve and unit mechanically by the extension spindle supplied taking care not to move the valve from the full shut position and also ensure that the universal joints on the intermediate shafts are in line and not at 90 to each other. (see Fig. 18). 2.6 LUBRICATION The actuator requires the minimum of maintenance as the gears and bearings are oil lubricated. It is preferable to change the oil every 12 to 18 months depending on site conditions and frequency of operation. Actuators for mounting direct on to a valve are fitted with a grease gun nipple for valve stem/spindle lubrication. Nipple to be charged with 4-5 strokes of grease gun every 3 to 6 months depending on site conditions. When an actuator is fitted to a valve at site, the latter nipple should be fully charged when commissioning, with the valve in the full open position and not excessively lubricated during service with the valve full shut. It is advisable to lubricate sparingly the drive gearing and bearings on the limit switch assembly. RECOMMENDED LUBRICANTS OR EQUIVALENTS: ROCOL MO 30 OIL - Worm gears, L.S. take off gears, torque switch gears, hand/auto assembly and all bearings. SHELL VITREA OIL No. 32 - Limit switch cam shafts, drive spindle and gear spindles. SHELL ALVANIA GREASE No. R3 - Indicator gears, grease gun nipple, rotary applications only. ROCOL MTS 1000 GREASE - Grease gun nipple, linear applications only. The intermediate and quadrant gearboxes are filled with LACERTA CL2X GRADE 2 GREASE and no further lubrication is normally required throughout its life. All equipment will be initially charged with lubricant before despatch. It is advisable to set up a routine maintenance schedule, particularly in cases when actuators are operated infrequently. 2.7 SPARES If at any time any spares or additional optional extras are required it would assist us to identify your requirements if the following information is given, this can be found on the identification plate attached to the actuator gearbox. a) Actuator Figure Number b) Actuator Serial Number ADT... c) Name of part required 10 Weir - First choice for power and industrial protection

2.8 Actuator Division Data Sheet 70275 TWO-WIRE LINEAR MILLI-AMP POSITION TRANSMITTER GENERAL DESCRIPTION The device is designed to take an input from a 1 kohm potentiometer (minimum dissipation 0.5 watt) mounted in the actuator and provide a DC current analogue output whose value is directly or inversely linear proportional to the potentiometer's angular or percentage position. The energisation supply may be in DC voltage over the range from 25 to 50 volts generally found in instrumentation systems and is applied over the same two conductors as provides the current analogue output. The impedance of the load is limited to a maximum of 750 Ohms and once the maximum and minimum ranging potentiometers incorporated within the device are adjusted to correspond to the maximum and minimum current of 20 and 4 ma then variation in supply voltage or line impedance can be ignored with respect to the current analogue. The design of the converter is in the form of a module hermetically sealed in silicone rubber and two test points are provided which are connected across an internally mounted 100 Ohm resistor in series with the output current. This enables the output current to be set from the voltage generated across the resistor i.e. 0.4 to 2.0 volts corresponding to 4-20 ma. The two output conductors are polarity insensitive as the DC supply is applied to the amplifiers within the module through a full wave diode bridge. The module incorporates and the operation is dependent on the facilities provided by the National Semiconductor 2-wire transmitter, type No. LH0045, and the limiting features of this and associated devices are as detailed under. Information is considered correct at time of publication but the company reserve the right to make changes without notice. Information provided in this document is for guidance only and does not form part of any contract entered into by the company. 11 Weir - First choice for power and industrial protection

SPECIFICATION - TYPE REF. 1081 Current Output: 4-20 ma Electrical Supply: 25-50v DC Potentiometer Input: From 1 kohm potentiometer Ambient Operating Range: -25 to +70ºC Output signal change with + or -25% change on supply voltage: 1% Maximum signal line impedance: 750 Ohm Physical Dimensions: 2" wide x 2 3 / 4 long x 7 / 8 thick (including connection pins) with 2-1 / 4 " diameter spring clips for mounting adjacent to actuator potentiometer and indicator assembly. SETTING PROCEDURE 1) Set actuator in closed (extended) position. 2) Slacken drive gear on potentiometer shaft and turn shaft so that milled slot on end of shaft is lined up with terminal No. 1 on the potentiometer body (0 ohms). The above instruction applies when looking from the indicator side of the potentiometer. 3) Using multiple analogue signal generator or similar equipment set to give a stable output in the range 25 to 50 volt d.c. 4) Connect output terminals from signal generators to 4-20 ma input terminals of milli-amp transmitter (typical terminals 18 and 19 - refer to contract wiring diagram). 5) Adjust the minimum (MIN) on the milli-amp position transmitter until 4 ma can be read on the digital ammeter. (Note clockwise rotation of the adjustment potentiometer reduces current on the MIN setting). 6) Run actuator to fully open (retracted) position and adjust the maximum setting (MAX) until 20 ma is observed on the digital ammeter. (Note clockwise rotation on MAX increases current). 7) Repeat steps 5 and 6 and final trim as required. 12 Weir - First choice for power and industrial protection

13 Weir - First choice for power and industrial protection ARRANGEMENT OF FIG. 9050M ROTARY ACTUATOR (3.1. FIG. 1)

14 Weir - First choice for power and industrial protection ARRANGEMENT OF FIG. 9151M ROTARY ACTUATOR (3.1.1. FIG. 2)

15 Weir - First choice for power and industrial protection TYPICAL ARRANGEMENT OF HOPKINSONS FIG. 9050M ACTUATOR WITH PART TURN OPERATOR (3.2. FIG. 3)

16 Weir - First choice for power and industrial protection TYPICAL ARRANGEMENT OF HOPKINSONS FIG. 9151M ACTUATOR WITH PART TURN OPERATOR (3.2.1. FIG. 4)

17 Weir - First choice for power and industrial protection TYPICAL ARRANGEMENT OF HOPKINSONS FIG. 9050M ACTUATOR WITH LEVER ARM OPERATOR (3.2.2. FIG. 5)

18 Weir - First choice for power and industrial protection TYPICAL ARRANGEMENT OF HOPKINSONS FIG. 9151M ACTUATOR WITH LEVER ARM OPERATOR (3.2.3. FIG. 6)

19 Weir - First choice for power and industrial protection ARRANGEMENT OF FIG. 9050M LINEAR ACTUATOR 1 1 / 2 MAX. TRAVEL (3.3. FIG. 7)

20 Weir - First choice for power and industrial protection ARRANGEMENT OF FIG. 9050M LINEAR ACTUATOR 3 1 / 2 MAX. TRAVEL (3.3.1. FIG. 8)

21 Weir - First choice for power and industrial protection ARRANGEMENT OF FIG. 9151M LINEAR ACTUATOR 3 1 / 2 MAX. TRAVEL (3.3.2. FIG. 9)

22 Weir - First choice for power and industrial protection SECTIONAL ARRANGEMENT OF FIG. 9050M ACTUATOR (WITHOUT SWITCHGEAR) WITH MECHANICAL VALVE POSITION INDICATOR (OPTIONAL EXTRA) AND TRANSMITTER (OPTIONAL EXTRA) (3.4. FIG. 10)

23 Weir - First choice for power and industrial protection SECTIONAL ARRANGEMENT OF FIG. 9151M ACTUATOR (WITHOUT SWITCHGEAR) WITH MECHANICAL VALVE POSITION INDICATOR (OPTIONAL EXTRA) AND TRANSMITTER (OPTIONAL EXTRA) (3.4.1. FIG. 11)

24 Weir - First choice for power and industrial protection SECTIONAL ARRANGEMENT OF FIGS. 9050M & 9151M FLANGED/GEARED MOTORS (3.4.2. FIG. 12)

25 Weir - First choice for power and industrial protection SECTIONAL ARRANGEMENT OF FIGS. 9050M & 9151M ROTARY/LINEAR CONVERTORS (3.5. FIG. 13)

26 Weir - First choice for power and industrial protection SECTIONAL ARRANGEMENT OF TYPICAL PART TURN OPERATOR (3.6. FIG. 14)

27 Weir - First choice for power and industrial protection SECTIONAL ARRANGEMENT OF TYPICAL LEVER ARM OPERATOR (3.6.1. FIG. 15)

28 Weir - First choice for power and industrial protection TORQUE SWITCH ASSEMBLY FOR FIG. 9050M & 9151M ACTUATORS (3.7. FIG. 16)

29 Weir - First choice for power and industrial protection GENERAL ARRANGEMENT & PARTS LIST OF 2 BANK LIMIT SWITCH & INDICATOR (3.8. & 3.8.1. FIG. 17)

30 Weir - First choice for power and industrial protection FIG. 9050M & 9151M PEDESTAL MOUNTED ACTUATORS (3.9. FIG. 18)

For spares or service enquiries please contact: North America Valve Customer Support Group Weir Power and Industrial 2360 Millrace Court Mississauga, Ontario L5N 1W2, Canada Tel: +1 905 625 7202 Servicecall: (877) 797 WEIR (9347) Fax: +1-905-766-4048 E-mail: valveservices@weirgroup.com Web: www.weirpowerindustrial.com Rest of World Weir Power and Industrial The Harlands Alloa FK10 1TB United Kingdom Telephone: +44 (0)1259 727550 Fax: +44 (0)1259 727570 E-mail: sales.coordinator@weirgroup.com Web: www.weirpowerindustrial.com Excellent Engineering Solutions www.weirpowerindustrial.com HOP 9050M & 9151M Issue 1982/May 2012