ADA Design Guide Washrooms & Showers

Similar documents
CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES

Chapter 6. Plumbing Elements and Facilities

DIVISION 6: PLUMBING ELEMENTS AND FACILITIES

Georgia-Pacific Compliance Guide for Title III of the Americans with Disabilities Act

ChapterS ACCESSIBLE BUILDINGS & FACILITIES Code References 1.) Plumbing fixtures conforming to "Accessible Buildings & Facilities"

Adult Elementary Preferred Standard Approved Standard Standard for New or Relocated Blanket Range Range Fixtures, Grab Bars, etc.

th Edition Florida Accessibility Code for Building Construction

ADA Checklist RESTAURANTS AND CAFETERIAS

Division 10 Catalog. Washroom Accessories from Bradley NEW. pg 16. distributed by RESTROOM DIRECT

ACCESSIBILITY DETAILS FOR RESTROOMS AND DRINKING FOUNTAINS

Division 10 Catalog. Washroom Accessories from Bradley. Introducing. pg 16. High Speed, High Efficiency Hand Dryers

ACCESSIBLE COMMUNITY BUILDER CHECKLIST

(2) For mounting heights suitable in schools and other facilities used primarily by children see section

ADA Entrance Accessibility

Surveyor Information

ACCESSIBILITY SELF-EVALUATION CHECKLIST

Division 10 Catalog. Washroom Accessories from Bradley. One source to perfectly accessorize every application BRADLEYCORP.COM

Location: Fraser Fort George, Prince George, Northern BC - Municipal : Trail (Great Northern Circle Route)

Accessibility Survey Techniques. John Salmen, AIA Andrew Yarrish, AIA Universal Designers & Consultants, Inc.

Dispenser Parts Part Description Replacement SKU

Also below is a limited list of the proposals which will be included in the first draft of the revised ICC/ANSI A117.1 standard for accessibility.

REAR +/- 94' 20' 10' 10'-4" 9'-6" 10'-3" 10' 20' 13'-2" Private Office 25. Private Office 23 Private Office 24 7'-1" Open Space 3 14'-7"

Accessible Routes. Chapter 1. Accessible Routes & Clearances. General Notes

The Moscone Center Facility Accessibility Information

FORM A: ACCESSIBILITY CHECKLIST. Questions. Possible Solutions A. PARKING. Location Name Location Address: (street address) (city) (state) (zip)

GOVERNOR S OFFICE of PLANNING AND RESEARCH

ADA Became Law In 1990

PALMER FIXTURE FULL LINE PRODUCT CATALOG. FAX ORDERS: CALL:

CITY OF LEMOORE AMERICAN WITH DISABILITIES ACT TRANSITION PLAN FINAL

APPLICATION OF SECTION 3.8 OF THE 2012 ONTARIO BUILDING CODE FOR: BARRIER-FREE AUDIT OF SENECA COLLEGE MARKHAM CAMPUS MARKHAM, ONTARIO

City of Los Angeles Department of Building & Safety Disabled Access Section Supplemental Plan Review Checklist No. 5 GROUP B AND GROUP M OCCUPANCIES

Enhanced Accessibility in the ICC/A Pacific ADA Update Conference Presented by: Kermit Robinson, CBO International Code Council

Shelter: Primary Shelter Secondary Shelter Respite Site Only Client Service Center Pet Shelter

Electric Vehicle Charging System Guidelines for Residential Buildings

Appendix D: ADA Self- Assessment

We ve designed this beautifully finished, stainless steel line for long-lasting strength, without sacrificing style and functionality.

County of Fresno. South Annex Jail ADA Transition Plan LARS ANDERSEN & ASSOCIATES, INC. Prepared by:

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER

BILLERICA OPEN SPACE AND RECREATION PLAN

Barrier Free Design Guide

BUILDING ELEMENTS DESIGNED FOR CHILDREN S USE THE GUIDE INCLUDES ICC/ANSI A STANDARDS THE ADA HAS OPENED THE DOORS OF ALL FACILITIES

ACCESSIBILITY GUIDE REVISED

Chapter 8 - Special Rooms and Spaces

Tork Elevation T26 High Capacity Bath Tissue Dispenser

NEVER OUT CATALOG WASHROOM ACCESSORIES

Center for Inclusive Design and Environmental Access State University of New York at Buffalo. RESNA, June 28, 2010 Workshop Schedule

BATH ACCESSORIES. P: PAPER TOWEL DISPENSERS

Washroom Accessories List Price Book 0216WAP

Installation Instructions

Oregon Conventi Center

ACCESSIBILITY. for Public Charging Stations. Plug-In Electric Vehicle Planning Toolbox

CHAPTER 90. STREETS, SIDEWALKS AND PUBLIC WAYS ARTICLE II. USE OF STREETS, SIDEWALKS AND PUBLIC WAYS DIVISION 10. SIDEWALK CAFÉS

K-SERIES PUBLIC USE LIFT OPERATING INSTRUCTIONS

REGULATIONS CONCERNING TRAILER PARKS COBB PUBLIC HEALTH

Planning Guide for Accessible Restrooms

WASHROOM. Inspirational materials for iconic washrooms

Amusement Rides. ADA Checklist for Existing Facilities. Amusement rides should be accessible to everyone, including people with disabilities.

NEVER OUT CATALOG WASHROOM ACCESSORIES

S-SERIES PUBLIC USE OPERATING INSTRUCTIONS

Spring Bathroom Safety

Accessible Housing by Design Residential Hoists and Ceiling Lifts

Roll Towel Systems. Controlled-Use Roll Towel Dispensers

S-SERIES ADA TRANSIT USE OPERATING INSTRUCTIONS

GLOBAL TOUCHLESS SENSING & GESTURE RECOGNITION MARKET ( )

DESIGN PRACTICE NOTE MOBILITY VEHICLE SIMULATIONS AT PEDESTRIAN CROSSINGS

Public Health Services San Joaquin Co.

G2 Optima Plus Flushometer

Making More of. January 2006 AMERICAN SPECIALTIES, INC.

Tork Intuition II Dispensing System

The TORK Difference Tork Washrooms and Workstations. Image Everyday Commercial Industrial & High-Traffic Healthcare Food Prep

CONTROLLED DISPENSING SOLUTION TOUCHLESS HYGIENIC ENVIRONMENT

St. Catharines Transit Commission Accessibility Plan. St. Catharines Transit Commission Accessibility Plan

Washroom Dispenser Service and Parts Manual Tork Elevation M1 Mini Pro Centerfeed Towel Dispenser A Revision Date:

FIGURE 2-1: LIFT (LEFT-SIDE) MOUNTING HOLES

2016 Product Description BradEx RX Qty BX-MEDICINE CABINET- RECESSED BX-TOWEL/WASTE UNIT- RECESSED

SHMD wide x 32 deep x 75-1/4 high

Demographics and Sales

Accessible Transportation: View of Accessible Samples of Design in Urban/ Small Towns from Selected Countries

Washroom Accessory Selection and Application Guide

Bariatric & Specialty. Closet Systems

Restroom & Shower Trailers

GENERAL REQUIREMENTS FOR ACCESS

MAG. Sloan Water Closets. Sloan Water Closets. Any Fixture, Any Flushometers

Washroom Dispenser Service and Parts Manual Tork Elevation M2 Pro Centerfeed Towel Dispenser A; A Revision Date:

CHAPTER 4: ACCESSIBLE ROUTES

Frost Products Ltd. Turns 50! Yesterday and today

CAUTION -TABLE OF CONTENTS- II. OPERATING INSTRUCTIONS

Chapter 5. General Site and Building Elements

Page

(New), (New)

WASHROOM. Inspirational materials for iconic washrooms

Accessibility facts and tips for key locations in Kingston & Area

Where Style Meets Confidence

Lower life cycle costs ahead.

Washroom Dispenser Service and Parts Manual Tork Elevation H2 Xpress Mini Interfold Towel Dispenser Revision Date:

SECTION FRAMELESS GLASS VERTICAL POST SHOWER DOOR SYSTEM

Where Style Meets Confidence. Meet the Latest, Greatest Premium Restroom Collection RESTROOM

NIC ENVIRONMENT TOUCHLESS HYGIENIC ENVIRONMENT STYLE HIGH FASHION STYLE HIGH FASHION STYLE

(New) Proponent: Hope Reed, New Mexico Governor s Commission on Disability (NMGCD) Add new text as follows:

NIC ENVIRONMENT TOUCHLESS HYGIENIC ENVIRONMENT STYLE HIGH FASHION STYLE HIGH FASHION STYLE

Transcription:

ADA Design Guide Washrooms & Showers Accessories Faucets Showers Toilets Lavatories interactive version available at bradleycorp.com/adaguide.pdf

Accessible Stall Design There are many dimensions to consider when designing an accessible bathroom stall. Distances should allow for common usage by people with a limited range of motion. A Dimension guidelines when dispensers protrude from the wall in toilet rooms and toilet compartments. 36" max 915 mm A Anything that a person might need to reach should be a maximum of 48" (1220 mm) off of the finished floor. 24" min 610 mm Toilet tissue needs to be easily within arm s reach. The outlet of a tissue dispenser must be between 24" (610 mm) minimum and 42" (1070 mm) maximum from the back wall, and per the ANSI standard, at least 18" above the finished floor. The ADA guide defines easily with arm s reach as being within 7-9" (180 230 mm) from the front of the bowl and at least 15" (380 mm) above the finished floor (48" (1220 mm) maximum). 12" min 305 mm 24" min 610 mm 42" max 1070 mm 48" max 1220 mm Door latches or other operable parts cannot require tight grasping, pinching, or twisting of the wrist. They must be operable with one hand, using less than five pounds of pressure. 7" 9" 180 230 mm 18" min 455 mm B Dimensions for grab bars. Grab Bars need to be mounted lower for better leverage (33-36" (840 915 mm) high). Horizontal side wall grab bars need to be 42" (1065 mm) minimum length. 12" max 305 mm 39" 41" 990 1040 mm 54" max 1370 mm C L B Vertical grab bars are not yet covered in the ADA guidelines, however, ANSI specifies the dimensions shown in the diagram. 42" min 1065 mm 33" 36" 840-915 mm 39" 41" max 990-1040 mm 18" min 455 mm 2

C Dimensions are shown for grab bars installed with protruding or recessed dispensers. Protruding (non-recessed) dispensers must be more than 12" (305 mm) above or 1½" (38 mm) below or at the end of grab bars. ANSI allows recessed dispensers at the ends of the grab bar. Recessed dispensers are allowed within the 12" (305 mm) space above and 1½" (38 mm) space below and at the end of a grab bar, for ADA the recessed dispenser must be flush. However, ANSI allows for ¼" (6 mm) projection in the allowed area. For ADA and ANSI, nothing can be installed directly behind the grab bar. C Protruding dispensers (Side View) ADA Figure 609.3 Grab Bar 12" min 305 mm Recessed dispensers (Side View) Grab Bar ¼" max 5 mm 12" min 305 mm Recessed Dispenser Front View 1½" min 40 mm 1½" max 40 mm 1½" max 40 mm Recessed Dispenser 1½" min 40 mm D Dimensions for rear grab bar installation. Rear wall grab bars shall be 36" (915 mm) long, and mounted so 24" (610 mm) are to the transfer side D 24" min 610 mm 36" min 915 mm 12" min 305 mm of the toilet and the other 12" (305 mm) to the wall side. The rear grab bar can be split or shifted to the open side to accommodate the required location of the flush control valves. Be sure to verify all accessibility guidelines with your local codes, as they are often more strict than national codes. 3

* Stall Dimensions Ambulatory Compartment Wheelchair Accessible Compartment Water Closet 17" 19" 430 485 mm 16" 18" * 405 455 mm * Advisory Specifications for Children Ages 3 through 12 Water Closet Centerline 60" min 1525 mm * 42" min clearance applies to all doors 59" min 1500 mm 4" min 100 mm 32" min 815 mm Ages 3 4 Ages 5 8 Ages 9 12 12" (305 mm) 12" 15" (305 380 mm) 15" 18" (380 455 mm) 35" 37" min 890 940 mm 42" min* 1065 mm 60" min 1525 mm Forward & Side Approaches for Unobstructed Reach 48" max height (1220 mm) 15" to 48" (380 1220 mm) to ensure forward reach 35" max (890 mm) to bottom of reflective surface 40" max (1015 mm) allowed over sinks and counters 33" to 36" (840 915 mm) Dimensions change if mounted over counter or lavatory. Operable parts must be beneath maximum height. 4

Toe Clearance (Adult) 9" min. 230 mm Partition 6" 150 mm Wheelchair Accessible Compartment Door Openings Alternate Door shall not swing into the required minimum area of the compartment 12" 18" Children 305 455 mm 16" 18" Adult 405 455 mm 60" min 1525 mm Toe Clearance (Children) Partition 6" 150 mm 56" min 1420 mm 59" min 1500 mm (Wall mounted W.C.) Adult (Floor mounted W.C.) Adult (Wall & Floor mounted W.C.) Children 12" min. 305 mm 48" max height (1220 mm) In order to create a safe environment for visually impaired patrons, fixtures must be detectable with a cane. The diagram above highlights this requirement. 4" max 100 mm ADA guidelines state that fixtures above 27" (685 mm) must not protrude from the wall more than 4" (100 mm). A low fixture such as a waste receptacle can satisfy this requirement if it is detectable below the protruding fixture (usually hand dryers or towel dispensers). Keep in mind that it s always important to double check requirements with local codes, as these supersede Federal requirements. Higher than 27" 685 mm 5

Single Occupant Room A Single occupant restroom design should allow for a patron to enter the room and maneuver to all fixtures from a wheelchair. The diagram at left shows how the ADA required dimensions create an environment that is accessible to anyone. These requirements may be change depending on the specific application. Check your local codes to be sure. Sinks must have 30" x 48" (760 x 1220 mm) of access. Measurement starts from the point where a person has 9" vertical clearance for their feet and 27" vertical clearance for their knees. 1 For wheelchair accessibility, the center line of the toilet must be between 16" 18" (405 455 mm) from the wall. This distance ensures that grab bars can be effectively used to maneuver one s self as needed. 30" x 48" (760 x 1220 mm) of clear floor space is required in every restroom. When 30" x 48" (760 x 1220 mm) clear floor space is provided beyond the arc of the door swing (shaded area to right of door opening), the door is permitted to swing into the clear floor space or clearance required for any fixture. A door may swing into a required wheelchair turning space. A door may not swing into a required clear floor or ground space at a fixture. However, an exception is made in single occupancy toilet rooms if another required clear floor or ground space is available that is outside of the radius of the door swing (section 603.2.3). This allows the wheelchair user adequate room to maneuver out of the path of the door. Be sure to verify all distances and heights with your local codes to ensure compliance. 1 Toe Clearance 9" 230 mm 30" min 760 mm 6" max 150 mm 17" 25" 430 635 mm 6

7' 2 m A 42" min 1065 mm 60" min 1525 mm 16" 18" min 405 455 mm 56" min 1420 mm 60" min 1525 mm 7' min 2 m Shaded Area: 30" 48" min 760 1220 mm 1 Knee Clearance 8" min 205 mm 27" min 685 mm 9" min 230 mm 30" min 760 mm 11" min 280 mm 25" 635 mm 7

Bradley Accessibility Solutions A Frequency Lavatory Systems B Towel Dispenser/Waste Receptacles Frequency lavatory systems feature a wave design that offers a unique solution for meeting ADA needs and standard height washing comfort. All Bradley Lavatory fixtures are designed so that ADA toe and knee clearance starts at the wall. Combination towel dispenser / waste receptacles provide practical use of space. To avoid a hazardous restroom, install towel dispensers next to the sink. This is more convenient for people with disabilities as well. In order to meet the 4" (100 mm) maximum limit for objects that protrude into the circulation path, consider recessed accessories. C Capacitive Sensing faucets D Mirrors Bradley s Capacitive Sensing Faucets automatically activate water flow through proximity sensing. Activation without grasping, pinching, or applying more than 5 lb pressure is required by ADA Guidelines. ADA compliance requires at least one mirror with the reflective surface beginning no higher than 40" (1015 mm) off the ground. Bradley recommends installing a full length mirror next to the sink to satisfy this requirement. This is a more convenient solution for people who use a wheelchair, and ensures compliance with any state or local code. D Bradley C B A 8

E Grab Bars The ADA emphasizes grab bar installation because they help the individual maintain balance, transfer, and prevent falls. Bradley E offers grab bars in various lengths, styles and finishes to fit any application. F Toilet Tissue Dispensers F To comply with ADA, toilet tissue dispensers cannot control delivery or limit paper flow. G Showers ADA Compliance for showers requires a hand-held shower head with 59" (1500 mm) hose that can be used both as a fixed-position shower head and as a hand-held shower. Shower controls must require less G than 5 lb of pressure with no grasping. Bradley offers several options for accessible showers. H Shower seats Bradley offers a variety of shower seats for ADA compliance, including bariatric models. Select anti-microbial models available. ANSI requires 18" (455 mm) minimum vertical grab bars in addition to the horizontal bars H required in accessible toilet or shower stalls. 9

Accessibility Standards & Guides The two primary sources for accessibility information are: The Americans with Disabilities Act (ADA) Architectural Barriers Act (ABA) Accessibility Guidelines (ADAAG) The American National Standards Institute (ICC/ANSI A117.1) Many people use the term "ADA compliant" generically even if they mean compliant to a different accessibility guide or code that applies to their specific building. ADA is a federal civil rights statute, not a building code. Though not enforced by building code officials, failure to comply is enforced through legal action from the Department of Justice. Accessibility Guidelines Organization Applicable to UFAS Uniform Federal Accessibility Standards Certain governmental organizations http://www.access-board.gov/guidelines-and-standards/buildings-and-sites/ about-the-aba-standards/ufas ADAAG Americans with Disabilities Act Accessibility Guide Private sector facilities and state and local government facilities https://www.access-board.gov/guidelines-and-standards/ buildings-and-sites/about-the-ada-standards/background/adaag ANSI* American National Standards Institute A117.1 Most state building codes http://www.access-board.gov/ * The American National Standards Institute is a commercial standards setting organization. A copy of the guides can be purchased at the ICC website: http://shop.iccsafe.org/topics/accessibility.html State Codes Accessibility codes may be part of a state s building codes or may be stand-alone codes developed by a separate state agency or department. Most state building codes have adopted ANSI A117.1, ADAAG, or a modification of the Standard, as the State Accessibility Code, thus making it enforceable. Always refer to your state s building codes to ensure compliance: http://www.access-board.gov/ 10

Federal Organizations & Accessibility Organization Applicable to Applicable Guidelines DOD Department of Defense Department of Defense installations UFAS http://www.access-board.gov/guidelines-and-standards/buildings-and-sites/ about-the-aba-standards/aba-standards DOJ Department of Justice Public accommodation, Commercial or State and Local Government facility installations except for Transportation facilities DOJ or UFAS http://www.ada.gov/2010adastandards_index.htm DOT Department of Transportation Department of Transportation installations UFAS http://www.dot.gov/citizen_services/disability/disability.html USPS United States Postal Service Postal Facilities UFAS http://www.access-board.gov/guidelines-and-standards/buildings-and-sites/ about-the-aba-standards/aba-standards HUD* Department of Housing and Urban Development Residential Structures covered by the ABA, except those funded by the DOD ABA http://portal.hud.gov/hudportal/hud?src=/program_offices/fair_housing_equal_opp/ disabilities/accessibilityr GSA General Service Administration Buildings subject to accessibility standards but not other standard-setting organizations UFAS & ADA/ABA http://www.access-board.gov/guidelines-and-standards/buildings-and-sites/ about-the-aba-standards/aba-standards * Fair Housing Act Design Standard 11

Advocate Lavatory System All-in-One Touchless Handwashing Convenience While restrooms with separate areas for handwashing and drying certainly meet ADA, maintaining the whole experience at one fixture is easier for anyone with impaired mobility. Imagine someone washing their hands then wheeling over to the dryer or towel dispenser. Their hands will be dirty by the time they reach the dryer and quite possibly have dripped all over their clothes, the chair or the floor before reaching the drying area. A wet floor is a potential slip hazard. The Advocate Lavatory System is a unique all-in-one handwashing and hand drying fixture with touchless activation of soap, water and dryer. The Advocate provides all users with the convenience and safety of having all necessary components within easy reach. Bradley's ADA Design Guide is of an advisory nature only and based on our interpretation of the ADA (and ICC/ANSI A117.1) requirements for public restrooms. Please consult the national, state and local codes in your area. 262 251 6000 800 BRADLEY bradleycorp.com W142 N9101 Fountain Boulevard Menomonee Falls, WI USA 53051 3931-2.5-0815