Sicherheitsschlösser

Similar documents
ELECTRIC LOCKS. Europrofile range

Mediator Albstadt, den

Electric locks ELECTRIC LOCKS

Electric Mortice Locks

Door closers catalogue 2008

(E: ABLOYEL410, EL Changing the opening direction - Changer fa direction djouverture - M3MeHeHue cmopohhocmu

Fire control. Electromagnetic fire Door Retainers. Available Models

T h e p e r f e c t l o c k s o l u t i o n. from effeff MEDIATOR. for entrance doors in. A p a r t m e n t b u i l d i n g s M E D I A T O R

ARC-51 N Overhead Concealed Door Closer and Springless Pivot

DIN EN 179 Emergency Exit Device

Automatic-action locks DORMA SVP/SVZ

Access Control Electric Locking. Security Systems. Reader Technology

Electrical Options Booklet. Table of Contents

Iserlohner Landstraße 117 D Menden DO 30.03, DO 2.17, DO 20.1

Wireless Access Controlled Door Solution

9700/F9700 SERIES RIM EXIT DEVICE

EL2000 Series Lockcase

Assa Classic. An ASSA ABLOY Group company

Series RE-10. Valve terminals > Technical details. Order code RE-10/**-***-*** Temperature range Medium +5 C C

Type Pneumatic Control Unit. Operating Instructions

Type Pneumatic Control Unit. Operating Instructions

Cylindrical Lockset Installation Instructions CL33600 TCRNE1 Series M812 - iclass Reader Option

Internal Single Door with Closer

Contents Introduction, Performance Features, Services & Guarantee Dimensional Details, Ordering Procedure & Handing Chart 6100 Series Vestibule Locks

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

/2017. Swing sink clamping element double-acting

Type 8635 Remote-Positioner. Zusatzanleitung. English Deutsch Français

Series RE-46. Valve terminals > Technical details. Order code RE-46/**-*-***-*** Temperature range Medium -10 C C

PRODUCT CATALOGUE 01/2018. PVC-U/wood/alu. paniclock. Emergency exit and anti-panic solutions. winkhaus.de

W Series Cylindrical Lever. W Series cylindrical lever lock

Chexit/RCM/DE5300. Chexit/RCM/DE5300 Service Parts. Chexit Field Wiring Cable. DE5300/RCM Field Wiring Cable. Table of Contents

Secured Door w/ Electric Lock - Solenoid

2.46. Locking and Security Information. Emergency exit device EN 179. Panic exit device EN New products and systems:

DLKEK3HN INSTALLATION INSTRUCTIONS

Gâches électriques. Elektro-Türöffner. Electric strikes. Cerraderos eléctricos PROFIX RADIUS STRIKES

1500 Series and 1600 Series Electric Strikes Installation Instructions

Installation and Wiring Instructions for the TL- Prefix SARGuide Illuminated Touchpad for 80 Series Exit Devices to ElectroLynx Connector System

LOCKS FOR METAL FRAMES.34

1500 Series and 1600 Series Electric Strikes Installation Instructions

Mechanical equipment Pneumatic stamping-unit Hand-toggle-lever presses

MACO DOOR LOCKS TECHNOLOGY IN MOTION

Ironmongery & Security Hardware Schedule

Electric Strikes. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

3400 Series

B Precision Ground Plates and Flat Bars. E Ground Precision Components. G Elastomer-Bars, -Sheets, -Sections

SLC Guard locking safety switch. The new generation of safe mechanical guard locking switches

L Standard Parts for Mould Making

FEATURES & SPECIFICATIONS. 100% internal parts quality inspection provides security, reliability and durability

The Antipanic Compliance to the standard EN1125

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

3540 Series Short Backset Mortice Locks. Keeler Hardware. telephone

DOOR TECHNOLOGY ORDER CATALOG SECTION GU-SECURY Automatic Smart Access Controlled

CERTIFICATE OF APPROVAL No CF 5418 C.ED. SCHULTE GMBH

Accessories. Chapter 16

Smart access means Dorma and Kaba Joining Forces

Section 6 Steel Gate Locks

Light/Medium-Duty Knob Locksets. CK4700 Series

Installation instructions BasicRelay CR / / 2012

Dialock Wall Terminals For outdoor and indoor use

Optional Latchbolts /8" (60 mm) Square or Round Corner, Dead Latch /4" (70 mm) Square or Round Corner, Dead Latch - Standard

CK4400 Series. Standard Duty Cylindrical Knob Locksets

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

HS-501-A... LC4 HS-503-A... LC4 HS-504-A... LC4 HS-505-A... LC5 HS-506-A... LC5 HS-507-A... LC5 HS-508-A... LC5 HS-509-A... LC6 HS-510-B...

STANDARD handles. outside. Rose. HoPPE LiVERPooL Aluminum. Aluminum. Aluminum. Aluminum. inside. HoPPE LiVERPooL. Aluminum. HoPPE LiVERPooL.

AM-751, AM-752, AM-753, AM-754, AM-755. Applications. Applicable Literature

3540 Series Short Backset Mortice Locks. ASSA ABLOY, the global leader in door opening solutions 2

Installation & Programming Manual. Quick Reference

Universal Gear Shift Sender for use with Lokar Indicators GSS-1000-LOK The easiest system to install and use on the market.

CL3100 Series. Lever Lockset Parts Manual

Cylinders. Hinges. Bolts

DOCUMENTATION APARTMENT LOCKS 2009 / 1

MAXIMA MOTORISED LOCKS

S6100 SERIES REVERSIBLE PANIC/FIRE EXIT RIM DEVICES INSTALLATION INSTRUCTIONS

Ersatzteilekatalog Nurmi Spare Parts Catalog Nurmi

Actuator LD3. Product Data Sheet Feature

PARTS MANUAL. B-16, B-21, and TB-16 Scoot-Crete Power Buggies

Escape Door. For all kinds of buildings, particularly Hospitals, Hotels, Offices and Institutional Buildings

Specialists and leaders in knobsets

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

ATELIER F/R - Business Line

4600 Heavy Duty Designer Deadlatch Handles With 4300, 4500, and 4900 Series Deadlatches

RIM LOCKS. An ASSA ABLOY Group brand ASSA ABLOY

Flue gas thermostat type 519

Motorized Electric Latch Retraction

GRADE 3 TUBULAR LOCKSETS INDEX:

7100SZ Series SafeZone Installation and Instruction Manual

BR230 MOTORIZED VIP. OPERATION and MAINTENANCE MANUAL

PUSH BAR EXIT DEVICES CROSS BAR EXIT DEVICES NARROW STILE EXIT DEVICES FEATURING LCWD STRIKES... 20

lkm7001 key override module Installation Instructions Converting The LKM7000 to The LKM7003

Keyless Upgrade Alarm

Kimba Spring Ersatzteilekatalog / Spare Parts Catalog

Pneumatic Axial Die Grinder also for Underwater Use Type , 0050

Repairing SpeedTreater-TX Spray Proximity Sensor

Installation Manual TWM Performance Short Shifter Cobalt SS/SC, SS/TC, HHR SS, Ion Redline and Saab 9-3

Security Screen Door Hardware

REC-11+ REMOTE RECEIVER UNIT

Door Hardware Catalogue. A complete range of furniture and accessories for IAC s high performance Noise-lock steel acoustic doors.

TURN-TiLT WiNDOWs A11.16 CHRONO ACCessORies

EasyStart Installation Instructions for Dometic Family RV A/Cs

3800 Series

Transcription:

Serrures de sécurité S e r r a t u r e d i s i c u r e z z a Sicherheitsschlösser Security locks Cerraduras de seguridad 39X/49X/79X D3532

8 EL46 - EL463 EL26, EL262 EL6, EL62 45 / 5 / 55 / 6 3 / 35 / 4 / 45 EL56 - EL563 EL36, EL362 EL16, EL162 2.5 88 /93 /98/113/133 55 /6 /65/8/1 16.5 Ø1.5 1 R7 63 66.5 3 35 6 22 1 2 8 Ø1.5 Ø8.5 Ø5.5 8 / Ø5.5 Ø8 21.5 25 25 76 92 (PZ) / 94 (RZ) 91 9 254 235 22 35 8 6 21.8 16.9 2 Ø8 15 Ø4.5 3 Ø6 8/ 9 3 Ø8 21.5 72(PZ) / 74(RZ) 168.5 2 / 24 38 Ø6 3 35 2 24 / 28 Max 7 3 Max 45 Max 45 X Y X Y max. 3 4 35 45 4 5 45 55 5 7 55 75 6 8 65 85 8 9 1 11 2

Contents Technical Data...4 Standards...4 Wiring Diagram...5 Emergency Exit Devices Installation According to EN 179...7 Panic Exit Devices Installation According to EN 1125...7 Settable Functions of 79X (narrow style)...8 Settable Functions of 79X (wooden door)...9 Drilling Scheme (Locks)...17 Drilling Scheme (Strike Plates for Wooden Door)...18 Installation Schematic...2 Inhalt Technische Daten... 1 Prüfungen... 1 Anschlussschema... 11 Installation für Notausgang entsprechend EN 179... 13 Installation für Anti-Panik-Ausgänge entsprechend EN 1125... 13 Einstellbare Funktionen 79X (Rohrrahmen)... 14 Einstellbare Funktionen 79X (Vollblatt)... 15 Bohrschema für Türdrückersteuerungen...17 Bohrschema für Schließbleche... 18 Installationsskizzen...2 3

TECHNICAL DETAILS ENGLISH Operating voltage *) **): 12 24V DC STAB (-1%, +15%) Current **): Micro switches **): Operating temperature: Bolt throw: Backset: Forend: Spindle: Max..4 A Idle.13 A (12V DC).65 A (24V DC) Max..5 A 3V AC/DC resist.1 W -2 C - +6 C 2 mm (deadbolt), 1 mm (double action bolt) 55, 6, 65 mm (wooden style) 3, 35, 4, 45 mm (narrow style) 2, 24 mm (wooden style) 24, 28 mm (narrow style) 9 mm (8 mm with snap spindle adapter) Connection cable: Z9XKAB (1 m) 16 x.14 mm 2 Door clearance: Settable functions: Monitoring outputs **): Strike plate: *) Not micro switch locks **) Not mechanical locks 2-5.5 mm Mechanical functions: - Opening direction of trigger bolt - Exit handle side (79X) Electrical function: *) **) - Fail locked / Fail unlocked Bolt deadlocked Lock open Trigger bolt in Handle down Cylinder used Sabotage Z9XSBL-1... Z9XSBL-4 TIP! Remove exit handle Allen screw of split spindle lock case to enable electrical controlling of both handles (through spindle lock function). In this case, remove or cover also the CE mark label. TESTED ACCORDING TO THE STANDARDS EN STANDARDS EN 179 3 7 6 1 1 3 4 2 A Exit EN 1125 3 7 6 1 3 2 1/2 A Panic exit EN 1634-1 Fire EN 61-6-1:21 EMC EN 61-6-3:21 EMC 4

WIRING DIAGRAM New wiring from 27-3 Marking: 49X/79X NEW WIRING on the product label no no c nc c nc no c *) not micro switch locks 12V DC (-1%) - 24V DC (+15%) STAB. *) LOCKED / OPEN *) (POTENTIAL FREE CONTROL) HANDLE DOWN MONITORING OUTPUTS Lock case White Solenoid Control Unit KEY CYLINDER USED Red GND / Control Green/red HANDLE DOWN Blue BOLT OUT Violet Turquoise Yellow/Red TRIGGER BOLT IN Brown Connection cable Z9XKAB Length 1m 16 x.14 mm 2 BOLT IN Orange Yellow SABOTAGE LOOP Grey Pink Micro switches of lock case when: - Key cylinder not used - Handle not used - Bolt out - Trigger bolt in - Bolt not in White Red Green/Red KEY CYLINDER USED Blue Violet Turquoise Yellow/Red Brown Orange Yellow COMMON FOR HANDLE DOWN KEY CYLINDER USED BOLT OUT COMMON FOR BOLT OUT TRIGGER BOLT IN BOLT IN COMMON FOR BOLT IN / TRIGGER BOLT IN Grey Pink SABOTAGE LOOP **) **) Potential free loop is closed when connection cable is connected to lockcase. 11 5

*) not micro switch locks + 12V DC (-1%) - 24V DC (+15%) STAB. *) LOCKED / OPEN *) (POTENTIAL FREE CONTROL) HANDLE DOWN MONITORING OUTPUTS WIRING DIAGRAM 49X/79X Old wiring until 27-2 Lock case Solenoid Control Unit KEY CYLINDER USED White +12-24V DC Red GND / Control Green/red HANDLE DOWN Blue BOLT OUT Turquoise COMMON Violet TRIGGER BOLT IN Brown Connection cable Z9XKAB Length 1m 16 x.14 mm 2 BOLT IN Orange COMMON Yellow SABOTAGE LOOP Grey Pink Micro switches of lock case when: - Key cylinder not used - Handle not used - Bolt out - Trigger bolt in - Bolt not in White Red Green/Red KEY CYLINDER USED Blue Turquoise Violet Brown Orange Yellow Grey BOLT OUT COMMON FOR BOLT OUT / HANDLE DOWN / KEY CYLINDER USED TRIGGER BOLT IN BOLT IN COMMON FOR BOLT IN / TRIGGER BOLT IN Pink SABOTAGE LOOP **) **) Potential free loop is closed when connection cable is connected to lockcase. Copyright Abloy Oy Joensuu Factory 25 6

EN 179 EMERGENCY EXIT DEVICES INSTALLATION ACCORDING TO EN 179 The following lock cases and handles are approved to be installed together in an emergency exit door. Strike plate Z9XSBL-1... Z9XSBL-4 must be used in the installation. Narrow style 79X 39X / 49X Wooden style 79X 39X / 49X Functional check after installation: Emergency exit (active) side and functional sensitivity tests: - Use the handle of exit side. Exit side is correctly set if the bolt goes inside the lock case irrespective of the electrical control. - In the profile door locks the force of handle is about 15 N (approximately 1.5 kg weight at a 1 mm distance from the pivot of the handle opens the lock). - In the wooden door locks the force of handle is about 25 N (approximately 2.5 kg weight at a 1 mm distance from the pivot of the handle opens the lock). According to EN 179 the force of handle must be less than 7 N. - Close the door slowly and check that the lock deadlocks. - Check that the bolts slide freely into the strike plate. The safety features of this product are essential to its compliance with EN 179. No modification of any kind, other than those described in these instrictions, are permitted. EN 1125 IKON DO 2.15.2 S6B3, S6B6 S6B8 IKON DO 2.15.1 S326, S426, S4K3 S4K6 FSB DO 2.3.1, DO 2.3.2 116, 123, 156, 17, 18, 188, 19, 1117, 1118, 1119, 1137, 1146, 1155, 116, 1161, 1162, 1177, 1178, 1191, 612, 616, 617, 619, 625, 627, 628, 646, 662, 665, 68, 681, 682, 688 PANIC EXIT DEVICES INSTALLATION ACCORDING TO EN 1125 HEWI DO 2.13.1, DO 2.13.2 111, 111.23, 114.23GK, 131, 132, 111X, 113X, 114X, 161X, 163X, 171X, 112X, 165X, 166X The following lock cases and push bars are approved to be installed together in a panic exit door. Strike plate Z9XSBL-1... Z9XSBL-4 must be used in the installation. Narrow style 39X / 49X / 79X Wooden style 39X / 49X / 79X effeff DO 3.4 8--11 (-), 8-1-11 (PZ) 8--11 (-), 8-11-11 (RZ) effeff DO 3.4 8--11 (-), 8-2-11 (PZ) 8--11 (-), 8-21-11 (RZ) JPM DO 3.5 DORMA 99-XX-A, 991-XX-A, 991-XX-A, 9911-XX-A, 991-XX-A, 9911-XX-A, 9911-XX-A, 99111-XX-A (87-3-A, 87-31-A, 87-32-A, 87-33-A) TESA DO 3.6 UNIVERSAL SERIE 1979G9xx Functional check after installation: Panic exit (active)side and functional sensitivity tests: - Push the push bar towards the door on the exit side. Exit side is correctly set if the bolt goes inside the lock case irrespective of the electrical control. - Force to open the lock by pushing the push bar is about 6 N (approximately 6kg). According to EN 1125 it must be less than 8 N. - Close the door slowly and check that the lock deadlocks. - Check that the bolts slide freely into the strike plate. Note! The length of the push bar must be at least 6 % of the width of the door. The safety features of this product are essential to its compliance with EN 1125. No modification of any kind, other than those described in these instrictions, are permitted. Recommended distance from a floor to a handle or to a push bar is between 9mm - 11mm. ENGLISH Lubricate the bolts of the lock case at least once a year. Use vaseline type lubrication. Note! ASSA ABLOY will not be liable for products in case these instructions are not followed. 7

SETTABLE FUNCTIONS OF 79X (narrow style) ENGLISH CHANGING THE FOREND Fig. A 1. Set the lock case forend up on the table. 2. Unscrew the fixing screws and remove the forend. Please note that the double action bolt and its two bushings do not fall off. 3. Set another forend and screw in the screws. Use LOCTITE 243 on each fixing screw. REMOVING THE MANIPULATION PROTECTION COVER Fig. B SETTING THE ELECTRICAL FUNCTION: FAIL LOCKED -> FAIL UNLOCKED Fig. C (Needed tool: 1.5 mm Allen key) The lock case is delivered in Fail locked mode: Power off -> Handle does not open the lock. Power on -> Handle opens the lock. The lock case can be changed in Fail unlocked mode. Then the lock works electrically in the following way: Power off -> Handle opens the lock. Power on -> Handle does not open the lock. The electrical function is changed from Fail locked into Fail unlocked mode in the following way: 1. Remove the Allen screw from the right-hand hole (Fig. C1). 2. Screw in the Allen screw in the left-hand hole (Fig. C2). The Allen screw should settle a little under the plastic edge, but please note not to use strength. When the Allen screw is fixed in the right-hand hole, the electrical function is Fail locked. When the Allen screw is fixed in the left-hand hole, the electrical function is Fail unlocked. SETTING THE EXIT HANDLE SIDE Fig. D (Needed tool: 2.5 mm Allen key) Exit side of the lock case is set with an Allen screw. The handle, of which side the Allen screw is fixed, always opens the lock, while the handle of the other side is controlled electrically. The lock case is delivered so, that the Allen screw is fixed on the caser side of the lock case. Exit handle side can be changed in the following way: 1. Remove the Allen screw from the caser side of the lock case (Fig. D1). 2. Screw in the Allen screw in the corresponding hole on the other side of the lock case (Fig. D2). CHANGING THE HANDING OF THE TRIGGER BOLT Fig. E (Needed tool: 2.5 mm Allen key) 1. Locate the Allen key between the two springs in the back of the lock case in the Allen screw-head of the trigger bolt (Fig. E1). 2. Loosen the Allen screw, so that the trigger bolt moves forward and can be turned around (Fig. E2). Please note not to unscrew the Allen screw. 3. When the handing of the trigger bolt is set, tighten the Allen screw (Fig. E3). When the needed settings have been done, attach the manipulation protection cover. ATTACHING THE CABLE Fig. F 1. Unscrew the fixing screw and remove the cable clamp. 2. Connect the cable into the connector. Fix the cable clamp. SETTING 8/9 SNAP SPINDLE ADAPTERS Fig. M 8/9 snap spindle adapters are set if the lock case is installed with 8mm spindle. The adapters must be set on the both sides of the lock case. There are two flat sides and two sides with a cup in a adapter. The round markings on the handle follower of a lock case denote the direction, in which the adapter is set. With 39X and 49X the direction of the adapter has to be noticed. With 79X the direction has no significance. 8

SETTABLE FUNCTIONS OF 79X (wooden style) ENGLISH CHANGING THE FOREND Fig. G 1.Unscrew the fixing screws and remove the forend. 2.Set another forend and screw in the fixing screws. Please note that a screw below the dead bolt is longer than the other screws. Use LOCTITE 243 on each fixing screw. SETTING THE ELECTRICAL FUNCTION: FAIL LOCKED FAIL UNLOCKED Fig. H The lock case is delivered in Fail locked mode: Power off -> Handle does not open the lock. Power on -> Handle opens the lock. The lock case can be changed in Fail unlocked mode. Then the lock works electrically in the following way: Power off -> Handle opens the lock. Power on -> Handle does not open the lock. The electrical function is changed from Fail locked into Fail unlocked mode by turning the changer, which is located on the case side of the lock case, in the following way: 1. Unscrew the fixing screw and pull out the changer. 2. Turn the changer around. 3. Put the changer back and screw in the fixing screw. Please make sure that the changer is straight and it fits tightly in the lock case. When the arrows on the changer and the lock case are positioned as shown in the figure, the electrical function is Fail locked (Fig. H1). When the arrows on the changer and the lock case are positioned as shown in the figure, the electrical function is Fail unlocked (Fig. H2). SETTING THE EXIT HANDLE SIDE Fig. I (Needed tool: 2.5 mm Allen key) Exit side of the lock case is set with an Allen screw. The handle, of which side the Allen screw is fixed, always opens the lock, while the handle of the other side is controlled electrically. The lock case is delivered so, that the Allen screw is fixed on the case side of the lock case. Exit handle side can be changed in the following way: 1. Remove the Allen screw from the case side of the lock case (Fig. I1). 2. Fix the Allen screw in the corresponding hole on the other side of the lock case (Fig. I2). CHANGING THE HANDING OF THE TRIGGER BOLT Fig. J (Needed tool: 2 mm Allen key) 1. Press the trigger bolt inside the lock case until the Allen screw of the trigger bolt is shown on the cover side of the lock case. 2. Unscrew the Allen screw. 3. Pull out the trigger bolt and turn it around. 4. Put the trigger bolt back in its place and press it inside the lock case. 5. Screw in the Allen screw. SETTING MANIPULATION PROTECTION PLUG Fig. K Set the brass plug on the outside of the lock case as shown in the figure. ATTACHING THE CABLE Fig. L 1. Connect the cable into the connector. 2. Use a cable tie to fix the cable to the lock case. Cut the cable tie short. SETTING 8/9 SNAP SPINDLE ADAPTERS Fig. M 8/9 snap spindle adapters are set if the lock case is installed with 8mm spindle. The adapters must be set on the both sides of the lock case. There are two flat sides and two sides with a cup in the adapter. The round markings on the handle follower of a lock case denote the direction, in which the adapter is set. With 39X and 49X the direction of the adapter has to be noticed. With 79X the direction has no significance. 9

(Vollblatt) (Rohrrahmen) (Vollblatt) (Rohrrahmen) Abstand Türe/Zarge: Anschlusskabel: (Z9XKAB) Einstellbare Funktionen: (79X) Z9XSBL-1... Z9XSBL-4 1

ANSCHLUSS 49X/79X Neuer Anschluss ab 3/27 Kennzeichnung: NEW WIRING auf Produkt-Etikett no no c nc c Gelb/Rot nc Anschlusskabel: Z9KAB no c Sabotageschleife (POTENZIALFREIER KONTAKT) Gelb/Rot SABOTAGE SCHLEIFE **) **) Der potenzialfreie Kontakt ist geschlossen wenn der Anschlussstecker am Schloss 11 11

ANSCHLUSS 49X/79X Sabotageschleife Alter Anschluss bis 2/27 nc c nc Anschlusskabel: Z9KAB no c (POTENZIALFREIER KONTAKT) **) Der potenzialfreie Kontakt ist geschlossen 12

Z9XSBL-1... Z9XSBL-4) müssen 79X (Rohrrahmen) 39X/49X (Rohrrahmen) 79X (Vollblatt) 39X/49X (Rohrrahmen) Z9XSBL-1... Z9XSBL-4 39X/49X/79X (Rohrrahmen) 39X/49X/79X (Vollblatt) 12 DORMA 13

ASSA ABLOY 79X Rohrrahmen (79X, Rohrrahmen) ÄNDERN DER STEUERFALLENPOSITION Federn in den Steuerfallenbolzen ( 14

Bei Verwendung der Adapter mit 39X/49X muss die Richtung beachtet werden. Bei Verwendung des Schlosses 79X muss keine Richtung beachtet werden. EINSTELLBARE FUNKTIONEN FÜR 79X (VOLLBLATT) EINSTELLUNG ARBEITS- ODER RUHESTROMFUNKTION (79X, Rohrrahmen) ÄNDERN DER STEUERFALLENPOSITION (rechte/linke Türe) 15

16 Bei Verwendung der Adapter mit 39X/49X muss die Richtung beachtet werden. Bei Verwendung des Schlosses 79X muss keine Richtung beachtet werden.

DRILLING SCHEME 39X / 49X / 79X Perçage approprié selon les installations 13 21,5 75,2 91 76 25 25 7,2 132 Copyright Abloy Oy Joensuu Factory 25 52 35 52 7 116,5 94 92 RZ +,5 21,5 27 / 32 / 37 / 42 17 28 87 276 245 18 PZ SCHEMA FREES EN BOOR TEKENINGEN Select suitable drillings according to fittings. Selecteer de juiste boren conform de diameter van de gaten in het slot. 17 17

DRILLING SCHEME 39X / 49X / 79X Forend 24mm Perçage approprié selon les installations 38 Copyright Abloy Oy Joensuu Factory 25 9, 95, 1,115, 135 18 (PZ) 23 (RZ) - +.5 13 (RZ) 13, 135, 14, 155, 175 18 (PZ) 51 52 72 (PZ) 74 (RZ) 21.5 8 38 55, 6, 65, 8, 1 3 1) Forend 2mm left Forend 2mm right 2.2 +,5 1) R9 +,5 167 + 1 R 9 +,5 24 +,5 235 64 98 SCHEMA FREES EN BOOR TEKENINGEN 18 + 1 18 2.2 + 1 +,5 Select suitable drillings according to fittings. Selecteer de juiste boren conform de diameter van de gaten in het slot. 18

Z9XSBL-1... Z9XSBL-4 Z9XSBL-2/ -4 Z9XSBL-1 Z9XSBL-3 R6 2 11 24 R6 Copyright Abloy Oy Joensuu Factory 25 +.5 - +.5-25 +,5 R6 R6 15 2 11 17 +,5 54 17 25 +,5 1 15 38 25 2 2 +,5 24 2 9 +,5 +,5 38 25 54 2 3 16 1 51 3 23 232 176 41 98 67 17 17 17 1 DRILLING SCHEME SCHEMA FREES EN BOOR TEKENINGEN 16 1) 2 24 28 / 2*) +,5 *) EA324 19

A C1 C2 B C 2

D D1 D2 4 1 E1 2 E3 3 E E2 21

F G 1 2 4 5 3 H H1 H2 22

I I1 I2 1 4 5 2 3 6 7 J 23

K L M 24

N O 25

P 26 Q

R S 27

Serrures de sécurité Serrature di sicurezza Sicherheitsschlösser Security locks Cerraduras de seguridad ASSA ABLOY Sicherheitstechnik GmbH Werk Albstadt Bildstockstraße 2 D-72458 Albstadt Telefon +49 74 31/1 23- Telefax +49 74 31/1 23-24 albstadt@assaabloy.de www.assaabloy.de An ASSA ABLOY Group brand ASSA ABLOY