Lighting Sciences, Inc. UL Verification Services 7826 E. Evans Rd. Scottsdale, Arizona 85260 USA P: 480-991-9260 F: 480-991-0375 lsi@ul.com www.lightingsciences.com Description: The sample(s) was(were) tested in accordance with the following applied standards/regulations: IES LM-41-98: Approved Method for Photometric Testing of Indoor Fluorescent Luminaire (withdrawn) IES LM-79-08: Approved Method for the Electrical and Photometric Measurements of Solid-State Lighting Products Prepared for: MAXLITE Approved by: JIM DOMIGAN WEST CALDWELL, NJ LABORATORY TEAM LEADER OCT 25, 2013 This report shall not be reproduced except in full without the written approval of the laboratory. The results in this report apply to the test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other similar products. Page 1 of 8
INTENSITY(CANDLEPOWER) SUMMARY OUTPUT LUMENS ANGLE ALONG 22.5 45 67.5 ACROSS 0 1260 1260 1260 1260 1260 5 1248 1247 1262 1265 1262 121 10 1228 1227 1243 1248 1246 15 1195 1194 1212 1220 1219 340 20 1150 1151 1170 1180 1180 25 1094 1097 1117 1130 1131 512 30 1027 1032 1054 1069 1071 35 953 957 980 997 1001 610 40 872 876 899 917 921 45 787 792 813 832 836 625 50 698 701 721 737 741 55 604 605 623 637 640 555 60 507 507 523 534 537 65 408 407 419 427 430 413 70 308 306 314 320 321 75 208 208 212 215 216 224 80 113 114 115 115 117 85 36 37 38 39 38 49 90 0 0 0 0 0 ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LUMINAIRE 0-30 974 28.23 0-40 1584 45.92 0-60 2764 80.12 0-90 3449 100.00 40-90 1865 54.08 60-90 686 19.88 90-180 0 0.00 0-180 3449 100.00 EFFICACY (LUMENS PER WATT): 100.6 *** THIS IS AN ABSOLUTE TEST *** 8 7 8 " LUMINOUS LENGTH: 44.750 INS WIDTH: 8.880 INS LUMINANCE SUMMARY CD./SQ.M. S/MH: 1.3 SC(ALONG): 1.2, SC(ACROSS): 1.3 ANGLE ALONG 45 ACROSS 45 4339 4504 4628 55 4108 4253 4369 65 3762 3879 3985 75 3141 3193 3260 85 1624 1700 1713 TESTED IN ACCORDANCE WITH IES PROCEDURES. Page 2 of 8
INTENSITY(CANDLEPOWER) DATA IN 2.5 DEGREE STEPS ANGLE PLANE OUTPUT ALONG 22.5 45 67.5 ACROSS AVERAGE LUMENS 0.0 1260 1260 1260 1260 1260 1260 2.5 1253 1252 1268 1270 1266 1262 5.0 1248 1247 1262 1265 1262 1257 121 7.5 1240 1238 1254 1258 1255 1249 10.0 1228 1227 1243 1248 1246 1239 12.5 1213 1212 1230 1236 1234 1225 15.0 1195 1194 1212 1220 1219 1208 340 17.5 1174 1174 1193 1201 1201 1189 20.0 1150 1151 1170 1180 1180 1166 22.5 1123 1125 1145 1157 1157 1142 25.0 1094 1097 1117 1130 1131 1114 512 27.5 1062 1066 1087 1101 1102 1084 30.0 1027 1032 1054 1069 1071 1051 32.5 991 996 1018 1034 1037 1015 35.0 953 957 980 997 1001 978 610 37.5 913 917 940 957 962 938 40.0 872 876 899 917 921 897 42.5 830 835 857 876 879 856 45.0 787 792 813 832 836 812 625 47.5 743 748 768 785 790 767 50.0 698 701 721 737 741 719 52.5 651 653 672 687 691 671 55.0 604 605 623 637 640 622 555 57.5 556 556 573 586 589 572 60.0 507 507 523 534 537 522 62.5 458 458 471 481 484 470 65.0 408 407 419 427 430 418 413 67.5 357 356 366 373 375 366 70.0 308 306 314 320 321 314 72.5 258 257 263 268 268 262 75.0 208 208 212 215 216 212 224 77.5 160 160 162 164 165 162 80.0 113 114 115 115 117 115 82.5 71 72 72 73 73 72 85.0 36 37 38 39 38 38 49 87.5 12 13 14 15 15 14 90.0 0 0 0 0 0 0 Page 3 of 8
AVERAGE LUMINANCE DATA CD./SQ.M (FOOTLAMBERTS) ANGLE ALONG 22.5 45 67.5 ACROSS 0 4914( 1434) 4914( 1434) 4914( 1434) 4914( 1434) 4914( 1434) 30 4627( 1350) 4661( 1360) 4759( 1389) 4825( 1408) 4824( 1408) 40 4441( 1296) 4472( 1305) 4580( 1336) 4680( 1366) 4689( 1368) 45 4339( 1266) 4375( 1276) 4504( 1314) 4601( 1343) 4628( 1351) 50 4233( 1235) 4269( 1246) 4373( 1276) 4481( 1307) 4497( 1312) 55 4108( 1199) 4121( 1202) 4253( 1241) 4346( 1268) 4369( 1275) 60 3956( 1154) 3971( 1159) 4081( 1191) 4177( 1219) 4191( 1223) 65 3762( 1098) 3763( 1098) 3879( 1132) 3950( 1152) 3985( 1163) 70 3507( 1023) 3504( 1022) 3591( 1048) 3660( 1068) 3663( 1069) 75 3141( 916) 3143( 917) 3193( 932) 3252( 949) 3260( 951) 80 2542( 742) 2559( 746) 2589( 755) 2594( 757) 2616( 763) 85 1624( 474) 1661( 484) 1700( 496) 1742( 508) 1713( 500) Page 4 of 8
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE =.20 CC 90 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 1.221.221.221.22 1.191.191.191.19 1.161.161.161.16 1.111.111.11 1.061.061.06 1.021.021.02 1.00 1 1.121.071.031.00 1.101.051.020.98 1.071.031.000.96 0.990.960.93 0.950.930.91 0.920.900.88 0.86 2 1.030.950.890.83 1.010.930.870.82 0.980.920.860.81 0.880.830.79 0.850.810.77 0.820.790.76 0.74 3 0.950.840.760.70 0.920.830.750.69 0.900.810.740.69 0.780.720.67 0.760.710.66 0.730.690.65 0.63 4 0.870.750.670.60 0.850.740.660.60 0.830.730.660.59 0.700.640.59 0.680.620.58 0.660.610.57 0.55 5 0.810.680.590.52 0.790.660.580.52 0.760.650.570.51 0.630.560.51 0.610.550.50 0.590.540.50 0.48 6 0.740.610.520.45 0.720.600.510.45 0.700.590.500.45 0.570.500.44 0.550.490.44 0.540.480.43 0.41 7 0.680.540.450.40 0.660.530.450.39 0.650.530.450.39 0.510.440.39 0.490.430.38 0.480.420.38 0.36 8 0.630.490.410.35 0.620.480.400.34 0.600.480.400.34 0.460.390.34 0.450.390.34 0.440.380.34 0.32 9 0.590.450.360.30 0.570.440.360.30 0.560.430.360.30 0.420.350.30 0.410.350.30 0.400.340.30 0.28 10 0.540.410.320.27 0.530.400.320.27 0.520.400.320.27 0.390.320.27 0.380.310.27 0.370.310.26 0.25 THE ABOVE COEFFICIENTS HAVE BEEN CALCULATED BASED ON LUMINAIRE LUMENS BECAUSE IN AN ABSOLUTE TEST THE BARE LAMP LUMENS ARE UNKNOWN. LIGHTING DESIGN CALCULATIONS MADE USING THESE COEFFICIENTS SHOULD THEREFORE USE THE LUMINAIRE LUMENS IN THE CALCULATION FORMULA LUMINAIRE INPUT WATTS 34.3 LABORATORY RESULTS MAY NOT BE REPRESENTATIVE OF FIELD PERFORMANCE. BALLAST AND FIELD FACTORS HAVE NOT BEEN APPLIED. TEST DISTANCE EXCEEDS FIVE TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE. Page 5 of 8
ELECTRICAL MEASUREMENTS INPUT VOLTAGE: 120.0 VOLTS AC INPUT CURRENT: 0.287 AMPS INPUT POWER: 34.3 WATTS POWER FACTOR: 99.6 PERCENT TOTAL HARMONIC DISTORTION: 6.04 PERCENT OFF STATE POWER: 0.00 WATTS INPUT VOLTAGE: 277.0 VOLTS AC INPUT CURRENT: 0.136 AMPS INPUT POWER: 34.5 WATTS POWER FACTOR: 91.5 PERCENT TOTAL HARMONIC DISTORTION: 21.30 PERCENT LIGHT OUTPUT LUMENS: 3449 lm EFFICACY: 100.6 lm/w SPECTRAL MEASUREMENTS X: 0.3366 y: 0.3675 u/u': 0.1999 v: 0.3273 v': 0.4910 Duv: 0.0109 CRI(R a ): 78.8 CRI(R 9 ): -4.0 CCT: 5349 K RADIANT FLUX: 10637 mw Page 6 of 8
Tabulated Spectral Power Distribution Wavelength [nm] Wavelength [nm] [mw/nm] [mw/nm] 380 0.24027 590 48.73258 390 0.45920 600 45.73719 400 0.55196 610 42.23633 410 1.17792 620 38.13255 420 5.77351 630 33.92493 430 20.23865 640 29.61568 440 59.51223 650 25.07691 450 72.47543 660 20.59881 460 35.73434 670 16.51292 470 20.81119 680 13.04387 480 20.26782 690 10.11614 490 27.29896 700 7.68538 500 36.94250 710 5.71735 510 43.83501 720 4.15370 520 47.89160 730 2.94968 530 50.81218 740 2.23020 540 53.42293 750 1.76311 550 54.75801 760 1.38303 560 54.86240 770 1.04196 570 53.62151 780 0.38813 580 51.28764 Page 7 of 8
LUMINOUS OPENING SIDE VIEW All testing was conducted in accordance with LM-79-08, Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products as published by the Illuminating Engineering Society of North America (IESNA). The condition of the item tested was new. Stabilization time before testing meets the stabilization requirements of LM-79-08. The test results (luminous distribution and flux) were obtained by using a Lighting Sciences series 6000 Type C Moving Mirror Goniophotometer The photometric reference standard used is a set of three incandescent luminous intensity standard lamps calibrated and traceable to the U.S. National Institute of Standards and Technology. The test results (colorimetric and luminous flux) were obtained by using a Labsphere Model LMS-760 Integrating Sphere. 4 geometry was used. Correction factors were applied for self-absorption. The colorimetric & photometric reference standard used is an incandescent spectral flux standard lamp calibrated and traceable to the U.S. National Institute of Standards and Technology. Power measurements were obtained with a Yokogawa WT210 power analyzer. Ambient temperature during testing was 25 C 1 C, measured using an Omega model DP460. Calibration certificates are on file at the laboratories of Lighting Sciences Inc. The results in this report apply to the test sample(s) mentioned in this report at the time of the testing period only and are not to be used to indicate applicability to other similar products. Page 8 of 8