SECTION VALVES PART 1 - GENERAL

Similar documents
A. This Section includes general duty valves common to several HVAC piping systems.

SECTION VALVES

SECTION (15110) - GENERAL DUTY VALVES FOR PLUMBING PIPING

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Herpteraium SECTION VALVES GENERAL

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Michigan State University Construction Standards. GENERAL-DUTY VALVES FOR PLUMBING PIPING Page

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

LOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS

Henderson Engineers, Inc. SECTION GENERAL DUTY VALVES FOR PLUMBING PIPING PART 1 - GENERAL REQUIREMENTS

Michigan State University Construction Standards. GENERAL-DUTY VALVES FOR HVAC PIPING Page

Division 23 - HVAC Section Switzerland Beallsville K-12 GENERAL DUTY VALVES FOR HVAC PIPING

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

SECTION GENERAL-DUTY VALVES FOR HVAC PIPING. A. Contents of Division 23, HVAC and Division 01, General Requirements apply to this Section.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Copyright 2016 AIA MasterSpec Premium 12/16 PRODUCT MASTERSPEC LICENSED BY ARCOM TO CONBRACO, INC.

1.2 REFERENCES.1 American National Standards Institute (ANSI)/ American Society of Mechanical Engineers (ASME)

SECTION GENERAL-DUTY VALVES FOR HVAC. A. Section includes valves for building services piping.

Copyright 2012 AIA MasterSpec Premium 06/12 PRODUCT MASTERSPEC LICENSED BY ARCOM TO CONBRACO, INC.

Valve Selection. 1. Function and service considerations

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

TENOCHCA HALL - PROJECT NO FAN COIL UNITS, RESTROOM AND FINISH RENOVATION

SECTION FACILITY FUEL OIL PIPING

DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION HVAC VALVES

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

SECTION VALVES

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC&R VALVES

SECTION VALVES PART 1 -GENERAL

SECTION (15444) - DOMESTIC WATER PACKAGED BOOSTER PUMPS

CITY OF TAMPA ADDENDUM 2. July 13, Contract 17-C-00030; David L. Tippin Water Treatment Facility Lime Slaker Replacement

SECTION PLUMBING PIPING VALVES AND ACCESSORIES PART 1 - GENERAL

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

A. This Section includes natural gas piping, specialties, and accessories within the building.

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION. A. Pipe, fittings, valves, and connections for sprinkler systems.

SECTION MISCELLANEOUS VALVES

1. All piping shall have flow arrows indicating direction of flow.

A. This Section includes the following domestic water piping specialties:

SECTION SWING CHECK VALVES

Iron Check Valves Illustrated Index

SECTION VALVES. A. Extent of Valve Work is indicated on the Drawings and by the Requirements of this Section.

SECTION VIII. (Sub-section 430) Wastewater Valves and Appurtenances. 1. General thru Gate Valves thru 430-3

A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less.

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

catalog C-NPS-1014 NIBCO Press System

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

MAINTENANCE GUIDELINES FOR NIBCO ¼ THROUGH 3 CLASS 125, 150, 200 & 300 BRONZE SWING CHECK VALVES FIGURE NUMBERS

1.1 PURPOSE A. This section is intended to define the general installation and minimum product requirements for hydronic and steam valves.

Size: 1/4 to 3. Material: 316 Stainless Steel, Carbon Steel,

IOM Manual. IOM Manual. Series 76/77.

PROJ. NO SECTION HYDRONIC PUMPS

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

STANDARDS and SPECIFICATIONS

VB VALVES & AUTOMATION

SECTION COMPRESSED-AIR PIPING FOR LABORATORY FACILITIES

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

Wafer and Globe Style Silent Check Valve. Operation, Maintenance and Installation Manual

15100 VALVES. E. Section Building Automation and Control System Guidelines

6SC SERIES MODELS 910F, 910FLW, 920F IRON SWING CHECK VALVE INSTALLATION OPERATION MAINTENANCE GUIDE

GENERAL-SERVICE COMPRESSED-AIR PIPING SECTION GENERAL-SERVICE COMPRESSED-AIR PIPING PART 1 - GENERAL

CUSTOM COMBINATION AIR VALVE

IMOI 2010 Rev 0

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

Installation, Operation, and Maintenance Manual. Gate, Globe, and Check Valves

MAINTENANCE GUIDELINES FOR NIBCO 2" THROUGH 10" CLASS 125, 150 & 250

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Installation and Maintenance Guidelines for. NIBCO Cast Iron, Alloy Iron and Ductile Iron Gate Valves 2 to 24 Class 125, 150, 175 and 250

SECTION VALVES AND OPERATORS

Cast Steel Valves. Contents Contents. Figure Number Index. Figure Number Cross Reference. Valve Type Class Stockham Jenkins

VALVES. A. Section HVAC Basic Materials and Methods. E. Section Building Automation and Control System Guidelines

Lead-free valves for potable water systems. Rev 02/17

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

***************************************************************************************************************

FACILITY WATER DISTRIBUTION PIPING

1. Wiring Diagrams: Power, signal, and control wiring.

Bolted Bonnet Valves. (BL Series) Cast Steel. Cast Steel Bolted Bonnet Valves - BL Series

Newco / OIC / Cooper Forged Valves. Operation & Maintenance. Manual

SECTION 1019 VALVES AND APPURTENANCES GENERAL: Valves shall have manufacturer's name and pressure rating cast in raised letters.

KVC VALVES AND PEX FITTINGS

Suggested Specifications

Cast-Iron Valves G101 DI BUTTERFLY VALVE LEVER... 2 G401 CI GLOBE VALVE CL G403 CI GLOBE VALVE PN G103 DI BUTTERFLY VALVE GEAR...

Distributed by: M&M Control Service, Inc brands you trust.

IMPORTANT NOTE! Please take the time to read this instruction sheet. Disregarding these guidelines may adversely affect your piping components

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

MILLCENTRIC FULL/100% POR T ECCENTRIC PLUG VALVE

CLASS 400 FORGED BRASS BALL VALVE

Val-Matic 3"-24" Butterfly Valve With LSA Actuator and External Stops

CATALOG C-NPS-0812 AHEAD OF THE FLOW. NIBCO Press System

Fabricated Bevel Gear Operator Bi-Directional Metal Seat 150 PSI Bi-Directional Resilient Seat 150 PSI

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

SOLENOID CONTROL VALVE

BULLETIN B&I 1195 BRONZE & IRON VALVES LUNKENHEIMER CINCINNATI VALVE COMPANY LICENSEE OF LUNKENHEIMER VALVES

SWING CHECK VALVES SERIES 52-SC SERIES 600

Brass, Bronze, Iron and Stainless Steel Valves

Installation, Operation, and Maintenance Manual Full Port Y-Pattern, Bolted Bonnet, Globe and Check Valves

TECHNICAL BULLETIN Top Entry Cryogenic Ball Valve Standard & Full Port

NIBCO INC. WORLD HEADQUARTERS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Series Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications.

McCannalok HIGH PERFORMANCE BUTTERFLY VALVE OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Transcription:

1.01 RELATED DOCUMENTS SECTION 15100 VALVES PART 1 - GENERAL A. The work in this section includes the furnishing and installation of all control valves and accessories shown on the construction plans and or required for proper operation of the pumping station. 1.02 SUMMARY A. This Section includes general duty valves common to several mechanical piping systems. 1.03 RELATED SECTIONS A. The following Sections contain requirements that relate to this Section: 1.04 SUBMITTALS 1. Division 2 - Section 02610 Pipe and Pipe Fittings. 2. Division 15 Section 15075 "Mechanical Identification." A. General: Submit each item in this section according to Division 1 Specification Sections. B. Product Data for each valve type. Include body material, valve design, pressure and temperature classification, end connection details, seating materials, trim material and arrangement, dimensions and required clearances, and installation instructions. Include list indicating valve and its application. C. Maintenance data for valves to include in the operation and maintenance manual specified in Division 1. Include detailed manufacturer's instructions on adjusting, servicing, disassembling, and repairing. 15100-1

1.05 QUALITY ASSURANCE A. Single-Source Responsibility: Comply with the requirements specified in Division 1 Section "Materials and Equipment," B. ASME Compliance: Comply with ASME B31.9 ASME B31.1 C. MSS Compliance: Comply with the various MSS Standard Practice documents referenced. 1.06 DELIVERY, STORAGE, AND HANDLING A. Prepare valves for shipping as follows: 1. Protect internal parts against rust and corrosion. 2. Protect threads, flange faces, grooves, and weld ends. 3. Set globe and gate valves closed to prevent rattling. 4. Set ball and plug valves open to minimize exposure of functional surfaces. 5. Set butterfly valves closed or slightly open. 6. Block check valves in either closed or open position. B. Use the following precautions during storage: 1. Maintain valve end protection. 2. Store indoors and maintain valve temperature higher than ambient dew-point temperature. If outdoor storage is necessary, store valves off the ground in watertight enclosures. C. Use a sling to handle large valves. Rig to avoid damage to exposed parts. Do not use hand wheels and stems as lifting or rigging points. 15100-2

PART 2 - PRODUCTS 2.01 MANUFACTURERS A. Manufacturers: Subject to compliance with requirements, provide products by one of the following: 1. Gate Valves: a. Crane Company; Valves and Fitting Division. b. Lunkenheimer/Cincinnati Valve Co. c. Mulleur Valve. 2. Ball Valves: a. Conbraco Industries, Inc.; Apollo Division. b. Milwaukee Valve Company, Inc. c. NIBCO Inc. d. Keystone. 3. Plug Valves: a. Grinnell Corp. b. NIBCO Inc. c. Keystone. 4. Swing Check Valves: a. Cla-Val Co. b. Crane Company; Valves and Fitting Division. c. Lunkenheimer/Cincinnati Valve Co. d. NIBCO Inc. 15100-3

2.02 BASIC, COMMON FEATURES A. Design: Rising stem or rising outside screw and yoke stems, except as specified below. 1. Nonrising stem valves may be used only where headroom prevents full extension of rising stems. B. Pressure and Temperature Ratings: As indicated in the "Application Schedule" of Part 3 of this Section and as required to suit system pressures. C. Sizes: Same size as upstream pipe, unless otherwise indicated. D. Operators: Use specified operators and handwheels, except provide the following special operator features: 1. Handwheels: For valves other than quarter turn. 2. Lever Handles: For quarter-turn valves 6 inches and smaller, except for plug valves, which shall have square heads. E. Extended Stems: Where insulation is indicated or specified, provide extended stems arranged to receive insulation. G. Threads: ASME B1.20.1. H. Flanges: ASME B16.1 for cast iron, ASME B16.5 for steel, and ASME B16.24 for bronze valves. I. Solder Joint: ASME B16.18. 2.03 GATE VALVES A. Gate Valves, 2-1/2 Inches and Smaller: MSS SP-80; Class 125, cold working pressure (CWP), cast-bronze body and bonnet, solid-bronze wedge, copper-silicon alloy rising stem, teflon-impregnated packing with bronze packing nut, threaded or soldered end connections; and with aluminum or malleable-iron handwheel. B. Gate Valves, 3 Inches and Larger: MSS SP-70, Class 125, CWP, ASTM A 126 cast-iron body and bonnet, solid cast-iron wedge, brass-alloy stem, outside screw and yoke, teflon-impregnated packing with 2-15100 - 4

2.04 BALL VALVES piece packing gland assembly, flanged end connections; and with cast-iron handwheel. A. Ball Valves, 4 Inches and Smaller: MSS SP-110, Class 150, CWP, ASTM B 584 bronze body and bonnet, 2-piece construction; chromeplated brass ball, standard port for 1/2-inch valves and smaller and conventional port for 3/4-inch valves and larger; blowout proof; bronze or brass stem; teflon seats and seals; threaded or soldered end connections: 2.05 PLUG VALVES 1. Operator: Lever operators with lock. A. Plug Valves: MSS SP-78, CWP, ASTM A126 cast-iron body and bonnet, cast-iron plug, Buna N, Viton, or teflon packing, flanged or grooved end connections: 1. Operator: Lever. 2.06 CHECK VALVES A. Swing Check Valves, 2-1/2 Inches and Smaller: MSS SP-80; Class 125, CWP, horizontal swing, Y-pattern, ASTM B 62 cast-bronze body and cap, rotating bronze disc with rubber seat or composition seat, threaded or soldered end connections: B. Swing Check Valves, 3 Inches and Larger: MSS SP-71, Class 125, CWP, ASTM A 126 cast-iron body and bolted cap, horizontal-swing bronze disc, flanged or grooved end connections. 3.01 EXAMINATION PART 3 - EXECUTION A. Examine piping system for compliance with requirements for installation tolerances and other conditions affecting performance of valves. Do not proceed with installation until unsatisfactory conditions have been corrected. 15100-5

B. Examine valve interior for cleanliness, freedom from foreign matter, and corrosion. Remove special packing materials, such as blocks, used to prevent disc movement during shipping and handling. C. Operate valves from fully open to fully closed positions. Examine guides and seats made accessible by such operation. D. Examine threads on valve and mating pipe for form and cleanliness. E. Examine mating flange faces for conditions that might cause leakage. Check bolting for proper size, length, and material. Check gasket material for proper size, material composition suitable for service, and freedom from defects and damage. F. Do not attempt to repair defective valves; replace with new valves. 3.02 INSTALLATION A. Install valves as indicated, according to manufacturer's written instructions. B. Piping installation requirements are specified in other Division Sections. Drawings indicate the general arrangement of piping, fittings, and specialties. C. Install valves with unions or flanges at each piece of equipment arranged to allow servicing, maintenance, and equipment removal without system shutdown. D. Locate valves for easy access and provide separate support where necessary. E. Install valves in horizontal piping with stem at or above the center of the pipe. F. Install valves in a position to allow full stem movement. G. Installation of Check Valves: Install for proper direction of flow as follows: H. Swing Check Valves: Horizontal position with hinge pin level. 15100-6

3.03 SOLDERED CONNECTIONS A. Cut tube square and to exact lengths. B. Clean end of tube to depth of valve socket with steel wool, sand cloth, or a steel wire brush to a bright finish. Clean valve socket. C. Apply proper soldering flux in an even coat to inside of valve socket and outside of tube. D. Open gate and globe valves to fully open position. E. Remove the cap and disc holder of swing check valves having composition discs. F. Insert tube into valve socket, making sure the end rests against the shoulder inside valve. Rotate tube or valve slightly to ensure even distribution of the flux. G. Apply heat evenly to outside of valve around joint until solder melts on contact. Feed solder until it completely fills the joint around tube. Avoid hot spots or overheating valve. Once the solder starts cooling, remove excess amounts around the joint with a cloth or brush. 3.04 THREADED CONNECTIONS A. Note the internal length of threads in valve ends and proximity of valve internal seat or wall to determine how far pipe should be threaded into valve. B. Align threads at point of assembly. C. Apply appropriate tape or thread compound to the external pipe threads, except where dry seal threading is specified. D. Assemble joint, wrench tight. Wrench on valve shall be on the valve end into which the pipe is being threaded. 3.05 FLANGED CONNECTIONS A. Align flange surfaces parallel. 15100-7

B. Assemble joints by sequencing bolt tightening to make initial contact of flanges and gaskets as flat and parallel as possible. Use suitable lubricants on bolt threads. Tighten bolts gradually and uniformly with a torque wrench. C. For dead-end service, butterfly valves require flanges both upstream and downstream for proper shutoff and retention. 3.06 APPLICATION SCHEDULE A. General Application: Use gate, and ball valves for shutoff duty. B. Domestic Water and Sewer Systems: Use the following valve types: 3.07 ADJUSTING 1. Gate Valves: Class 125, bronze or cast-iron body to suit piping system. 2. Ball Valves: Class 150, CWP, with stem extension. 3. Plug Valves: Neoprene-faced plug, Buna N packing. 4 Bronze Swing Check: Class 125, with rubber seat. 5. Cast Iron Swing check Valves: Class 125, swing type as indicated. A. Adjust or replace packing after piping systems have been tested and put into service, but before final adjusting and balancing. Replace valves if leak persists. END OF SECTION 15100-8