JUMO heattherm Type a Protection temperature limiter, as a panel-mounting thermostat a Compensated for ambient temperature

Similar documents
JUMO heattherm Type Protection temperature limiter, as a panel-mounting thermostat Compensated for ambient temperature

Surface-mounting Thermostats Series ATH-SW

Thermostats for panel mounting Series ETH

Explosion-protected surface-mounting Thermostat ATH-Ex Series

Panel-mounting Thermostats EM Series. B Operating Instructions 11.06/

Immersion fittings. Brief description. Installation options Standard. Series Page 1/7. Data Sheet

Panel-mounted Thermostats

Pressure Transmitter JUMO dtrans p30 Type

JUMO BlackLine Lf-GT / -EC electrolytic 2-electrode conductivity cells

JUMO safetym TB/TW Temperature limiter, temperature monitor according DIN EN

Pressure transmitter JUMO dtrans p02

J TS 7090 Thyristor power switch

Analog input module. Brief description. Page 1/8. Data Sheet

JUMO heattherm-at and JUMO heattherm-dr

Measuring Cells for free chlorine, chlorine dioxide, ozone

JUMO tecline Ci-S. Inductive conductivity and temperature sensor for general process engineering. Installation Instructions T94Z001K000

Products Temperature, Control, Monitoring

Contact Dial Thermometer

JUMO tecline H2O2 JUMO tecline PAA Sensor for hydrogen peroxide and peracetic acid

Contact dial thermometer

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

Ball valve for pipeline systems

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Rod thermostat with micro switch

Automation Temperature, Control, Monitoring

Communication module. Brief description. Block structure Features. Page 1/5. Data Sheet

Logic module. Brief description. Features. Block structure. Data Sheet Page 1/5

Panel-mounting thermostats

Pressure Transmitter JUMO dtrans p30 Type

Process Connections for Dial Thermometers

JUMO dtrans p20 DELTA Differential pressure transmitter Type

JUMO DSM software. PC software for management, configuration, and maintenance of digital sensors. Operating Manual T90Z001K000

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Operating Instructions for Paddle Bellows Flow Monitor. Model: FPS-P...

Pressure controls and thermostats, type KPS

Temperature controls, Type RT

When ordering, please state type and code number. Suitable sensor length. Max. Cap. range. tube adjust- see also Accessories. sensor. temp.

Pressure switch and Thermostat Type CAS

High-pressure switch for gas, air, flue gases and combustion products GW 500 A4 GW A4/2 HP

Pressostats and thermostats CAS

Pressure switch for gas, GW 500 A4 GW 500 A4/2

JUMO dtrans p20 DELTA

Screw-in resistance thermometers with plug connector

TEMPERATURE CONTROL AND MONITORING HYDRAULIC COMPONENTS

Safety technology/equipment

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

ATEX/IECEx RTD temperature probe

Differential pressure switches for air, flue and exhaust gases GGW A4-U/2

Self-operated Temperature Regulators Type 1u Temperature Regulator

Differential pressure gauges with Bourdon tube

BSW , -493, -494 Mechanical Rotary Cam Switches. User's Guide. Mechanical Rotary Cam Switches BSW BSW BSW

Data sheet Pressure controls and thermostats type CAS August 2000 DKACT.PD.P10.B B0616

Differential pressure switches for air, flue and exhaust gases Pressure switch for gas

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

JUMO MIDAS Pressure transmitter

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

Head form B Head form J Cable socket, angle type KOMBITEMP TEMPERATURE SENSOR WITH LOCAL DISPLAY. Including products with:

Pressure and temperature controls, Type CAS

Self-operated Temperature Regulators Temperature Regulator Type 1u

JUMO ecoline O-DO. Optical Sensor for Dissolved Oxygen. B Operating Manual /

Self-operated Temperature Regulators Type 1u Temperature Regulator

JUMO tecline CR Electrolytic Conductivity Cells in stainless steel or titanium

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

Solenoid Valve Island Type 3965

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

Series P74 Differential Pressure Controls, without time delay

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Operating Instructions for Plastic Flow Meter. Model: KSK

Liquid filled Thermometers

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Mini temperature switch Stainless steel switch enclosure Model TXS

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

KombiTemp. Head form B / Head form J Cable socket, angle type Diesel engine dial thermometers. Temperature Sensors with local display

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

Conductivity Measurement CLM 280

JUMO Safety Performance

Screw-in melt RTD temperature probes

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

MPP 910 IDS MPP 930 IDS

Differential pressure transmitter PASCAL Ci4 Delta P

Pressure and Temperature Switches

Screw-in melt thermocouples

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

Multiple Lever Types. Proximity Limit Switch. Circuitry. The Proximity Limit Switch utilises magnetic switching to sense and trigger off ferrous

AC/DC2-wire Type Cylindrical Proximity Switches

Industrial-Thermometer

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

JUMO ecotrans Lf 01/02

Pressure transmitter for elevated media temperatures

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Precision Bourdon tube pressure gauges

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Basic Series Accessories Low Voltage Current Transformer Class 1

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Transcription:

JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO Instrument Co. Ltd. JUMO House Temple Bank, Riverway Harlow, Essex CM 0 TT, UK Phone: +44 179 635533 Fax: +44 179 6356 e-mail: sales@jumo.co.uk Internet: www.jumo.co.uk JUMO Process Control, Inc. 8 Technology Boulevard Canastota, NY 13031, USA Phone: 315-697-JUMO 1-800-554-JUMO Fax: 315-697-5867 e-mail: info@jumo.us Internet: www.jumo.us Data Sheet 60.031 Page 1/5 JUMO heattherm Type 60031 a Protection temperature limiter, as a panel-mounting thermostat a Compensated for ambient temperature Brief description Thermostats control and monitor thermal processes. The JUMO heattherm, type 60031, is a protection temperature limiter STB. The panel-mounting thermostat operates on the principle of liquid expansion. The electrical switching device is a snap-action switch. Switching action Protection temperature limiter STB with lock-out and self-monitoring facility If the temperature at the probe exceeds the set limit, the snap-action switch is operated through a transmission mechanism, the circuit is opened and the snap-action switch is locked out mechanically. After the temperature has fallen below the limit by about 10% of the limit value, the snapaction switch can be reset manually. Failure of the measuring system, i.e. a leakage of the expansion liquid, will cause the pressure under the diaphragm to drop, thus permanently opening the circuit. The thermostat can no longer be reset. If the probe cools down to below -0 C (approx.), the same circuit will open, but will close again when the temperature rises. Temperature compensation A deviation of the ambient temperature at the switch head and capillary from the +C calibration ambient temperature will result in a shift of the switching point. The temperature compensation reduces this switching point shift to a minimum. Approvals DIN Reg. No. Tests STB 116904 3 PED 97/3/EC 1 You will find the Declarations of Conformity at: www.jumo.net or ask for them to be sent. 1 applied for limit: 180 C max. 3 mode of operation as per EN 60 730--9: Type BFHKLP

JUMO GmbH & Co. KG 36035 Fulda, Germany Data Sheet 60.031 Page /5 Technical data Housing sheet steel, zinc-plated Base black polyester resin compound Fixing M 10x1, with hexagon nut and protective cap Enclosure protection IP00 to EN 60 59 Limit temperatures for transport and storage: -50 to +50 C in use: +80 C max. Nominal position (NL) unrestricted Weight approx. 0.1 kg Ambient temperature effect A deviation from the ambient temperature at the switch head and capillary from the + C calibration ambient temperature will result in a switching point shift of about -0.1 C / C (measured at +10 C limit, permanently set, and with 3000 mm capillary length) Electrical contact Contact type snap-action switch with single-pole (n.c.) break contact, lock-out and signal contact Contact rating break contact (contacts 1-): 16 (.5) A, 30 V AC +10%, p.f. = 1 (0.6) 0.5A, 30 V DC +10% signal contact (contacts 1-4): (0.4) A, 30 V AC +10%, p.f. = 1 (0.6) 0.5A, 30 V DC +10% gold-plated snap-action switch, code 70: 0.1A, 4 V AC/DC, Connection A 6.3-0.8 to DIN 4644 Switching point accuracy see order details Switching reliability To ensure maximum switching reliability, we recommend a minimum loading of: AC/DC = 4 V, 0 ma with silver contacts AC/DC = 10 V, 10 ma with gold-plated contacts (code 70) Probe length L in mm Limit value Probe dia. 95 C 100 C 110 C 10 C 350 C 70 to 130 C 95 to 10 C 10 to 150 C 150 to 180 C 4mm 6mm 7 7 Connection diagram 4 1 1 4

JUMO GmbH & Co. KG 36035 Fulda, Germany Data Sheet 60.031 Page 3/5 Dimensions Type: 60031/80 Type: 60031/81

JUMO GmbH & Co. KG 36035 Fulda, Germany Data Sheet 60.031 Page 4/5 Order details Panel-mounting thermostat JUMO heattherm, type 60031 Order code (1) Basic type 60031 Panel-mounting thermostat JUMO heattherm, with single-pole snap-action switch () Basic type extensions 80 Protection temperature limiter (STB), permanently set, with (n.c.) break contact, lock-out and signal contact 81 Protection temperature limiter (STB), adjustable, with (n.c.) break contact, lock-out and signal contact (3) Limit value Max. probe temperature 095 +095 C +0/-5 C +145 C 100 +100 C +0/-5 C +145 C 110 +110 C +0/-5 C +145 C 10 +10 C +0/-5 C +145 C 350 +350 C +0/-0 C +405 C 671 +070 to +130 C +0/-15 C +150 C (freely adjustable) 1 666 +095 to +10 C +0/-5 C +145 C (adjustable, notch positions 95, 100, 110, 10 C) 1 67 +10 to +150 C +0/-10 C +175 C (freely adjustable) 1 673 +150 to +180 C +0/-10 C +10 C (freely adjustable) 1 (4) Capillary length 1000 1000 mm 000 000 mm 500 500 mm 3000 3000 mm.... special length (specify in plain text, in 1000 mm steps, max. length: 5000 mm) (5) Material of capillary 40 Cu (copper) 1.5 mm dia. (6) Insulation of capillary 00 without 13 with (7) Insulation length (starting from housing) 0 none 450 450 mm 950 950 mm (8) Process connection (PA) 10 A = plain cylindrical probe 0 U = temperature probe, no support tube (9) Thread of process connection 00 no thread (process connection A) 13 external thread G 1/ (10) Material of process connection 00 only with process connection A 46 CuZn (brass) 01 St (steel) 0 CrNi (stainless steel 1.4571)

JUMO GmbH & Co. KG 36035 Fulda, Germany Data Sheet 60.031 Page 5/5 Order details Panel-mounting thermostat JUMO heattherm, type 60031 Order code (11) Fitting length S (immersion tube length) 000 no pocket 100 100mm 150 150mm 00 00mm 300 300mm 400 400mm.... special length (specify in plain text) (1) Diameter of process connection 4 4 mm 6 6 mm 8 8 mm (13) Extra codes (TZ) 000 no extra code 70 gold-plated snap-action switch contacts 708 snap-action switch without signal contact (1) () (3) (4) (5) (6) (7) (8) (9) (10) (11) (1) (13) Order code 60031 / - - - - - - - - - - / Order example 60031 / 80-110 - 000-40 - 13-450 - 10-00 - 00-000 - 6 / 000 1 only with basic type extension 81 see data sheet 60.6710 for additional probe mountings