Model UT - Undertank Reference

Similar documents
SlimLine (TM) Reduced Diameter Reference Electrode

Process Vessel Reference Electrode

Designed with potential in mind

1 1/4 NPT FILTER SIZE DESIGNATION PRICE 2 NPT FILTER REPLACEMENT SCREENS FOR 1 1/4 & 2 FILTERS 1 1/4 SCREENS 2 SCREENS HOLE SIZE DESIGNATION PRICE

SIGNET 2750 ph/orp Sensor ENGLISH

2 NPT FILTER REPLACEMENT SCREENS FOR 1 1/4 & 2 FILTERS

1 1/4 NPT FILTER 2 NPT FILTER REPLACEMENT SCREENS FOR 1 1/4 & 2 FILTERS 1 1/4 SCREENS 2 SCREENS. Hole Size Designation 150 Mesh 1M150

Signet 3719 ph/orp Wet-Tap

SIGNET 3719 ph/orp Wet-Tap

Underground Cathodic Protection Coupon

HOSES & LANCES. Hoses & Lances 15,000 PSI (1,034 BAR)

Model AX Custom Anodes

JUMO MIDAS Pressure transmitter

Test Stations and Pipe-to-Soil Potential Measurements

EQUIPMENT & ACCESSORIES

Vacuum Filters. Catalogue Edition 2

General Specifications

Connection 1 Connection 2 ft m in mm psi bar in mm

WRANGLER 2016 WHEEL DRIVE, PAD ASSIST & ELECTRIC MODELS

Signet 3719 ph/orp Wet-Tap Assembly

For securing wire terminals, cables, connectors, and other samples for pull testing [36.8] 1.0 [25.4]

ASI Model 8374 Automatic Roll Towel Mechanism Owner s Manual

DEMA SPRAY CLEAN DISPENSERS MODEL 605T INSTALLATION INSTRUCTION

The 606T-2 unit is designed to be used as a spray or foam unit where up to two chemicals can be attached to the unit along with a clean water rinse.

Atomizer 36-DC User Guide

3/4" BRASS AGRICULTURAL SPRINKLERS WR-33 WR-32 WR-35

Dinosaur Flexible Wiring Duct

ScienceLine ph combination electrodes

Dissolved Oxygen Measurement System with Air Blast Cleaner

Combination ph/redox (ORP) Sensors

Electric Vibratory Box Feeder Retrofit Kit

Packaged Parts Overview

SNOW PLOWS OPERATION & MAINTENANCE MANUAL

Heat-Shrinkable Tubing

1) ALTERNATOR REMOVAL:

DEMA SPRAY STATION II MODEL 606T-2 INSTALLATION INSTRUCTIONS

Tubing and Accessories

PeroxiDraw Dispenser

For securing wire terminals, cables, connectors, and other samples for pull testing [36.8] 1.0 [25.4]

NEW STYLE - TANK ADAPTER Socket x Socket Dimensions Also Applicable to 8170E-XXX & 8170V-XXX

DEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION

AP300 Series Combination ph/redox (ORP) Sensors. Measurement made easy. A reliable economic solution for a wide range of applications

SECTIO N 15 Phone: (866) Fax: (888)

Spray Clean 606T-2 Installation Instruction

Combination ph/redox (ORP) Sensors

HVAC-R COPPER TUBE AND FITTINGS

Heat-Shrinkable Tubing

AXLE MOUNT MODELS: FILM ROLLER MODELS: OPERATING & SERVICE PARTS MANUAL TABLE TOP OVERWRAPPERS MODEL 625A MODEL 625A MINI MODEL 825A MODEL 875A

4-ELECTRODE CONDUCTIVITY SENSORS

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

Overview. Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) Bosch Rexroth Corp.

METAL PRESSURE PIPE PIPE & TUBING PIPE & TUBING GALVANIZED PRESSURE PIPE ASTM A-53 ERW BLACK GAS PIPE ASTM A-53 ABOVE GROUND LARSEN SUPPLY CO., INC.

SCHEDULE 80 PVC PRESSURE FITTINGS L80P EFFECTIVE JULY 1, 2017 REVISED PRODUCTS PRICE LIST INCLUDES: SCHEDULE 80 PVC 1/4 TO 12

RTD Elements c/w tails.

Schedule 80 - CPVC Pressure Fittings

SPIRAL VIBRATION DAMPERS FOR AAC, AAAC, ACSR, COPPER, SC/AC & SC/GZ CONDUCTORS. Part Number


ARC WELDING REELS: Series SWCR. Protective Ground Lug Boot part no Series WCR (Air Power AWCR)

Schedule 80 - CPVC Pressure Fittings

Commercial Sewage & Waste Water Systems

Wiring Duct T1 Series - Slotted

VACUUM VALVES INSTRUCTIONS FOR USE

T1 Wire Duct Series: Rigid PVC, self-extinguishing Light GREY RAL 7030 or WHITE. 6 Feet 6 3/4 Inches Duct complete with cover

INTERNATIONAL CATALOG HVACR COPPER TUBE & FITTINGS

Castle Model TSM-21 Standard Screw Pocket Machine

CURRENT TRANSFORMER MODEL N. SS BAND SECURES BRACKET (view of screw clamp band omitted for clarity) 0.25 x 0.50 SLOT (2 PLACES)

LANCER EVOLUTION (2008 ) MUD FLAP MZ531356EX (Black with aluminum plate) MZ531357EX (Black standard) INSTALLATION AND HANDLING INSTRUCTIONS

Design of a Station for Pump Testing

ARB 4x4 ACCESSORIES Corporate Head Office

19 Swell Action Latch

BEETLE Rotary Cleaning for Curved Pipes/Tubes

accqpulse Velocity Profiler Sensor Installation Guide

For securing wire terminals, cables, connectors, and other samples for pull testing [36.8] 1.0 [25.4]

Table of contents. 1. Overview Product ordering and information Appendix Wiring duct styles 4. 1.

Hollow cone nozzles.

Good for ABS applications. Temperature rating -87ºF to 150ºF (-66ºC to 66ºC) Temperature rating -87ºF to 150ºF (-66ºC to 66ºC)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

Improved Stainless Steel T-Bolt Clamps

ONE TOUCH FITTINGS Series WP2

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

THE AquaBlast & RocketRide FUNSLIDES

King Dome. user manual

Section One. Steel Underground. PVC Accessories Bolt-on Dresser Fittings Solvent PVC Pipe Fittings Gasketed PVC Pipe Fittings

Caltech Design Contest ME72 Engineering Design Laboratory Fall Term, 1999 Kit List

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

AUTOMOTIVE HOSE G611 FUEL LINE. Tube: Smooth, black, oil and gasoline resistant nitrile rubber.

HVACR WHOLESALE CATALOG

per Length (In) (mm) (In) F (ft.) (In)

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

Stainless Steel Water Well Screens and Accessories

HelaGuard. Non-Metallic Conduit & Fittings

ATTENTION: PLEASE READ AND UNDERSTAND ALL INSTRUCTIONS AND WARNINGS BEFORE ASSEMBLING, INSTALLING OR USING THIS PRODUCT. PRODUCT REGISTRATION WARNING

Thermocouples. General Applications Tube and Wire. Thermal Devices, Inc. Mount Airy, Maryland USA

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

General Specifications

Compact Electric Actuated Ball Valves PVC Body, Teflon/EPDM Seals 1/2 to 1 inch Pipe

FIRST ORDER. 1 3/8" NPT Electric Solenoid Valve 12-VDC Air PN: JFSV Arduino Mega 2560 R3 PN: DEV IMU Digital Combo Board PN: SEN-10121

Thermocouples. General Applications Tube and Wire. Performance Capabilities. Features and Benefits. Typical Applications. Construction and Tolerances

M3500 Industrial Pressure Transmitter

Transcription:

Model UT - Undertank Reference Typical Applications Measuring potential profiles in perforated or slotted pipes beneath aboveground storage tanks Featuring All wood membrane for contact to the electrolyte #14 RHW/USE lead wire is standard Model UT1 Model UT1 was designed for use on tanks where the undertank piping terminates in a short radius ell. A user-attached sponge can be fitted to reduce contact resistance. Models UT2 and UT3 Models UT2 (for 2 in. dia. pipe) and UT3 (for 3 in. dia. pipe) can be left permanently in place in the slotted pipe and pulled through whenever potential profiles are required. Shipping wt. approx. 1 lbs (1/2 kg) plus wire #14 RHW wire: 1.5 lbs (0.7 kg) /100 ft (30 M) Design life 5 years (intermittent use). Shipping wt. approx. 2 lbs (1 kg) plus wire #14 RHW wire: 1.5 lbs (0.7 kg) /100 ft (30 M) Design life 10 years (intermittent use). Model UT reference electrodes are designed for taking potential profiles through perforated or slotted pipes beneath aboveground storage tanks. Contact to the electrolyte is through an all wood membrane which is more resistant to breakage and will not clog with salts or dry out as rapidly as a ceramic membrane. Electrodes outfitted with two non-metallic ring bolts can be pulled through from either end of the pipe. When access is only available at one end of the pipe, use the S version which has a threaded socket at one end. This can be pushed or pulled from the open end. U Series Underground Reference Electrodes UT3.doc 11/15 EDI 2015

Installation Instructions Undertank Reference Electrodes These instructions apply to EDI Model UT undertank reference electrodes with gelled copper/copper sulfate (Cu/CuSO 4, model code CUG) or gelled silver/silver chloride (Ag/AgCl, model code AGG) elements. After removing electrode from carton, record the serial number and QC test potential; these are located on the yellow tag attached to the lead wire. Be sure to follow the correct procedures. Failure to follow these procedures will significantly shorten the life of the product. Storage Models UT2 and UT3: When the electrode will not be used for more than a week, the vinyl cap should be placed so that it covers the wood membrane. If the vinyl cap is lost or damaged, an alternative storage procedure is to wrap the wood membrane with a damp (potable water) paper towel and then overwrap it with either a clingy plastic wrap or aluminum foil to retard evaporation. Model UT1: Use the overwrapping procedure described above. The electrode should be stored indoors at room temperature and out of the sun. Before reusing the electrode, remove cap or overwrap and soak it for a couple of hours in potable water. Model UT2 and UT3 electrodes may be left in the perforated pipe beneath the tank provided it is in a location where the temperature will not exceed 110ºF (45ºC). Usage Before pulling the reference electrode through a perforated pipe for the first time, the pipe must be flushed and cleared by dragging a dolly of equal or greater diameter through it in order to clear any obstructions. This pipe should be covered when not in use. Tow lines are to be attached to both eyebolts for pulling the reference electrode. Never pull the reference electrode by pulling on the lead wire. There must be a moisture film on the bottom of the perforated pipe in order to make valid potential measurements; it may be necessary to flush the pipe to create this film. Since the measurement path usually has high resistance, it will be necessary to use a high input impedance (>100 Meg) meter to obtain a valid reading. AS perforated pipe

#14 AWG RHW/USE lead wire CPVC electrode body 7/8inØx2inlong hardwoodring,1-1/8inøx1/2in non-metallic eyebolt(2) 1inODx1/2inID Specify as EDI Model UT1-xxx-LWnnn where xxx=elementtype CUG for gelled Cu/CuSO4 AGG for gelled Ag/AgCl nnn=leadwirelengthinfeet optional replaceable sponge heldinplacebyeyebolt Model UT1 undertank reference electrode is designedtofitthroughshortradius2inchpipe ells. This allows the development of under-tank potential profiles using existing piping installed for monitoring purposes. For tanks with long radius pipeells,modelut2orut3ispreferred. Note: Thisproductisintendedforshorttermusewhen developing potential profiles beneath an AST. It will not provide long term performance in continuous use. Reduced diameter undertank reference electrode EDI 2011 SCALE 8JUN2011 UT-3

#14 AWG RHW/USE lead wire 2 1/4 in Ø 2 1/2 in Ø x 1 1/2 in wood membrane Model UT3 is designed for use in slotted pipes 3 inch diameter or larger with long radius ells. Use model UT1 in pipes with short radius ells. 6 1/4 in non-metallic eyebolt (2) 1 in OD x 1/2 in ID 1 5/8 in Ø 1 3/4 in Ø x 1 in wood membrane ModelUT2 is designed for use in slotted pipes 2 inch diameter or larger with long radius ells. Use model UT1 in pipes with short radius ells. 5 1/2 in Specify as EDI Model UTz-xxx-LWnnn where z = size code, 2 or 3 xxx = element type, AGG or CUG and nnn = lead wire length in feet Element Types AGG = saturated gelled Ag/AgCl CUG = saturated gelled Cu/CuSO4 Undertank reference electrode EDI 2011 SCALE 8 JUN 2011 UT-4

ModelUT3S is designed for use in slotted pipes 3 inch diameter or larger. Socket-end UT2 and UT3 reference electrodes have a 1 inch NPT female pipe thread on the wire end and a solid end cap on the other end. All other dimensions and features are similar to the eye-bolt ended electrodes. Model UT2S is designed for use in slotted pipes 2 inch diameter or larger. Specify as EDI Model UTzS-xxx-LWnnn where z = size code, 1, 2 or 3 xxx = element type, AGG or CUG and nnn = lead wire length in feet Element Types AGG = saturated gelled Ag/AgCl CUG = saturated gelled Cu/CuSO4 ModelUT1S is designed for use in slotted pipes smaller than 2 inches. It has a 3/4 NPT-F thread on the wire end and a nylon bolt securing the sponge on the other end. All other dimensions and features are similar to the eye-bolt ended electrodes. Socket end undertank reference electrodes are designed for use in slotted pipes where only one end is accessable. A threaded PVC pipe is attached to the wire end and the electrode pushed through the pipe. Socket end undertank reference electrode EDI 2012 SCALE 17 SEP 2012 UT-5