Excell. Installation Manual. Door Mechanism Model Number

Similar documents
Electrical Accessories

GRAND UNION CANAL UXBRIDGE WEST LONDON UB8 2GH. Accommodation schedule. Block B

RV-7 / RV-8 / RV-10 Installation Kit Trio Gold Standard Roll Servo

Transmission systems: Multiple components that have the same type of movement (rotational, linear, etc)

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

Your interest is appreciated and hope the next 37 pages offers great profit potential for your new business. Copyright 2017 Frank Seghezzi

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

OpenAir Electric Damper Actuators GBB/GIB Series NSR Rotary 24 Vac - Modulating Control

Mechanics and Mechanisms. What is do you think about when you hear the word mechanics? Mechanics. Is this a mechanism? 2/17/2011

SERVICE SHOP NOTES. Use ohmmeter to check the resistance between the leads.

Instruction Manual. Made in Israel Distributed by:

SUREPOWR TM SERIES -SURE 24/25 FIELD INSTALLATION INSTRUCTIONS

SERIES 700/700E FACTORY KEYLESS UPGRADE INSTALLATION MANUAL

SL-1000 Stairlift OWNER S MANUAL

Installation Manual DELT. Platform stairlift. Web: Tel: Mobile:

CHAPTER 6 GEARS CHAPTER LEARNING OBJECTIVES

Series 41 and 81 Modutrol IV Motors

RotoTract Remote Racking Operating Manual

Models Affected: Certain 2013 Model Year Propane Vision Buses Equipped with Ford 6.8L Engines CORRECTIVE ACTION ---- PROCEDURE

Small engine EFI conversion kits Hall Effect Sensor technical spec. Hall Effect Sensor. Technical Spec ECOTRONS LLC COPY RIGHTS ECOTRONS

Ford 6.0L Regulated Return Kit

COMPONENT WORK SAMPLE 14 Integrated Peer Performance MAINTENANCE MANUAL

Ball Speed Display Manual

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

GCSE Design & Technology Systems and Control Technology

Power Flame Incorporated

HORIZONTAL SLIDING DOORS

VG7000 Valve Linkage for M100 Series Motor Actuators

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

SWING GATE OPENERS 24V DC GEAR MOTOR

AUTOMATIC CONTROL ROLLING DOOR OPENER

LUBRICATION SECTION INDEX DESCRIPTION REAR DOOR HINGE HOLD-OPEN ASSEMBLY INSTRUMENT PANEL COMPARTMENT DOOR HINGE

Moments. It doesn t fall because of the presence of a counter balance weight on the right-hand side. The boom is therefore balanced.

Stairfriend Stairlift Owner s Manual

KEANE MONROE a member of the record group

D-4070 Two Stage Pneumatic Actuator

Installation Instructions for Model CityFix

OPERATOR S MANUAL PNEUTORQUE PTM, PTME, TRUKTORQUE SERIES STALL TOOLS. Part Number Issue 5 Original Instructions (English)

MWL Milltronics Weight Lifter. Instruction Manual June 2001

SL-1000 Stairlift OWNER S MANUAL

Model 1026 OWNERS MANUAL. Wheelchair Assist. 17 Wx18 Lx35 H

All levers are one of three types, usually called classes. The class of a lever depends on the relative position of the load, effort and fulcrum:

AUTOMATIC CLUTCH Models

Tach-Drive Distributor Reconditioning Joe Fisher PDF prepared by Dave Zuberer Link to Thread on the Corvette Forum (C1-C2)

McCANNA Actuation Systems B

Porsche 928 with 16v LH-Jetronic Fuel System

SUREPOWR TM SERIES -SURE 49 FIELD INSTALLATION INSTRUCTIONS

Rolling Work Seat

Timing Belt: Service and Repair Timing Belt Replacement

MF Series MS Series

INTRODUCTION 2EZHM DESCRIPTION

Fiat X1/9 1500cc Engine Timing Belt Replacement, Cam Timing and Static Ignition Timing. Photos courtesy of Don Doan.

INSTALLATION INSTRUCTIONS FOR ELECTRIC CHOKE KIT P/Ns , S, &

Crank Trigger Hardware Installation

A Literature Review and Study on 4 Wheel Steering Mechanisms

HCB-8 AFTER BLENDING. Servoreeler vertical cradle support Registration slots in adapter bracket

Installation and Service Manual

NOTE. Figure 2. Mounting Configurations (View shown from rear of LED Bar) Figure 3. Rear Deck Mounting NOTE

NOTE. Figure 2. Mounting Configurations (View shown from rear of LED Bar) Figure 3. Rear Deck Mounting NOTE

301.7D CR. Mini Hydraulic Excavator

Make Your Own Electricity

AQA GCSE Design and Technology 8552

Simple Free-Energy Devices

ALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm)

Instruction Manual May milltronics MWL WEIGHT LIFTER

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

π H-2319 PORTABLE STRETCH WRAP DISPENSER uline.com TOOLS NEEDED 9/16" Crescent Wrench 9/16" Socket Wrench

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

JK Upper 1/2 Door Installation Instructions. Front 1/2 Door Installation

Tech Note Truck 14 & 15.5 Twin Plate Cast Iron Type Installation Guidelines

Stairfriend Stairlift Owner s Manual

Drop-in Alternative to Tyco/Kilovac* 500+ Amp EV200, plus a lot more (Compare Products) RoHS Compliant, all date codes

Product design: Mechanical systems

S-SERIES AND K-SERIES SERVICE MANUAL

The Standard Mounting Arrangements for S&C Alduti-Rupter Switches

Five Ways to Latch Your Tailgate

Kits (53mm), (48.5mm)

(1032 mm) 30.5 (775 mm) 44 ( mm)

Levelling valve

T his chapter contains instructions for installing the RICON S-Series (ADA) Transit Use Wheelchair and Standee Lift

Instruction Manual for Barber-Colman Series EA Electric High Torque Actuators

MODEL CMS INSTALLATION INSTRUCTIONS A. INTRODUCTION 1. USAGE 2 2. HOW IT OPERATES 2 B. SPECIFICATIONS 1. ELECTRICAL 3 2.

Transporting Non-Ambulatory Passengers. Transporting Non-Ambulatory Passengers. Issue One: Your Responsibility

! CAUTION! ! WARNING!

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101

FROG KIT. Installation Instructions for a Pair of gates... TECHNICAL HELPLINE THE FROG-P KIT CONSISTS OF:

Technical Procedure. SUBJECT: Operation, Maintenance and Retrofit Procedures. DATE: February 2018

DICTATOR RTS Tube Door Closer

Rear Bumper Cover Unpainted ( ):

Intelligent Lift Interlock System Installation Instructions

Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual

928 Motorsports Supercharger Installation Copyright 2007, 928 Motorsports, LLC All Rights Reserved

66 CHAPTER FOUR. Spark Plug Removal Refer to Figure 28 for spark plug wive routing according to engine.

Installation Instructions For Part Number: Scoop and Snorkel Kit

PNEUTORQUE PTM, PTME & TRUKTORQUE TM SERIES STALL TOOLS

Installation Instructions Jeep CJ-7

Bistable Rotary Solenoid

Troubleshooting Guide Problem Index

Specifications. S&C Switch Operators Types AS-1A and AS-10a. Conditions of Sale

Timing Belt: Service and Repair Timing Belt Replacement

Transcription:

Excell Installation Manual Door Mechanism Model Number 7189-001 This Document Copyright of Excell Machine Co., Inc. 602 S. Fourth Avenue Mansfield TX 76063 Phone (817) 473-6121 Fax (817) 473-6170

The variety of makes and models of motor busses precludes the possibility of presenting detailed, step-by-step instructions for possible applications. However, the EXCELL Door Operating Mechanism can be installed readily by any good mechanic with a working knowledge of bus-door operation. The information to follow should prove helpful. In addition to the notations given here, a number of drawings and photos have been included showing examples of a considerable variety of installations. From all of this, we suggest that a mechanic can work out the particular details of any installation requested of him. The EXCELL Bus-Door Operating Mechanism can be mounted over the doors in most cases. Where space over the doors proves to be too confining, the unit can be mounted over the windshield. In either case, it must be securely fastened to the bus frame and positioned so that the travel on the mechanism drive bell crank will give full open and close motion to the doors. When replacing a manual door control, a drive shaft and a bell crank may need to be provided to serve as the connection between the EXCELL mechanism and the door. See figure 1. If replacing an air-operated unit, the existing linkage may be utilized, often with little or no modification. See figure 8. Figure 7 shows an example of the EXCELL mechanism mounted over the windshield using a cam follower and track to operate a set of bi-fold doors. Other examples of bi-fold doors being operated with the cam follower and track, as well as with a bell crank and linkage, are to be seen in figure 1, figure 3, and figure 4. LIMIT-SWITCH ADJUSTMENT Limit switches are located at the rear of the EXCELL mechanism unit behind the drive shaft. The top switch stops clockwise rotation; the bottom switch stops counter-clockwise rotation. Adjust the cams on the drive shaft so that the switches just make contact when the door is fully open, and when it is fully closed. IMPORTANT: check to see that the motor does not remain hot in a stalled condition!

CONNECTING POWER TO THE EXCELL UNIT Connect the yellow wire to +12 VDC. Ground the frame of the EXCELL mechanism to the bus frame. The black wire serves as the signal connection wired through the control switch. When the switch completes the circuit to ground, the unit runs in one direction; when the circuit is interrupted, the unit runs in the opposite direction. The control switch can be located anywhere that is convenient to the driver of the bus. Figure 1 With some bi-fold door installations, it may be necessary to make an offset in the door s drive shaft in order to clear the door framing.

Figure 2 Schematics showing one method of rigging linkage for double-out and 1-in, 1-out doors. Figure 3 EXCELL Model 8901 Door Control Mechanism operating a set of bi-fold doors. Broken lines indicate open position with trailing leaf and upper track omitted. Figure 4 A bi-fold door installation using a cam

follower and track, with the follower mounted in the crank arm at 5 1/2 center-to-center. Figure 5 An example of a double-out set of doors using a double bell crank on the mechanism drive shaft. May also be used for 1-in, 1-out doors by repositioning the linkage. Figure 6 Overall dimensions of the Excell Bus-Door Operating Mechanism.

Figure 7 a set of bi-fold doors using the Excell mechanism mounted over the windshield in a Carpenter bus.

Figure 8 Showing the Excell mechanism set to operate bi-fold doors on a Ward Patriot Bus. A standard retrofit mechanism was used to convert the door operation from air to electric, utilizing the existing drive brackets. Shown with cover on mechanism removed and doors closed, and with mechanism cover in place and doors open.